DIGITALMULTIMETER
Contents
1. Connect the black and red test leads to the COM and Q terminals respectively Connect the red test lead to the anode black test lead to the cathode of the diode under testing The meter will show the approx forward voltage of the diode If the lead connection is reversed only figure OL displayed 4 6 Capacitance measurement A To avoid electrical shock and or damage to the instrument disconnect circuit power and discharge all high voltage capacitors before measuring capacitance Use the dc voltage function to confirm that the capacitor is discharged Set the rotary switch to MF range Connect the black and red test leads to the COM F terminals respectively Connect the test leads to the capacitor being measured and read the displayed value NOTE The meter may take a few seconds 200uF range 30 seconds to stabilize reading This is normal for high capacitance measuring To improve the accuracy of measurements less than 4nF subtract the residual capacitance of the meter and leads 4 7 Frequency measurement Set the rotary switch to Hz range Connect the black and red test leads to the COM and Hz terminals respectively Connect the test leads across the source or load under measurement and read the displayed value Note Reading is possible at input voltages above 3V rms but the accuracy is not guaranteed In noisy environment it is preferable to use shield cable for measuring small signal 4 8 Tempera
2. VQ terminals respectively Connect the test leads to the circuit being measured and read the displayed value In order to ensure the best accuracy in measurement of low resistance short the test leads before measurement and memory the test probe resistance in mind This necessary to subtract for the resistance of the test leads NOTE For measuring resistance above 1MQ the meter may take a few seconds to stabilize reading This is normal for high resistance measuring When the input is not connected i e at open circuit the figure OL will be displayed for the overrange condition 4 4 Continuity measurement To avoid electrical shock and or damage to the instrument disconnect circuit power discharge all high voltage capacitors before testing for Continuity o Set the rotary switch to Pt range Press FUNC key to select measuring mode Connect the black and red test leads to the COM and Q terminals respectively Connect the test leads to the resistance in the circuit being measured When the test lead to the circuit is below 40Q a continuous beeping will indicate it Note continuity test is available to check open short of the circuit 4 5 Diode measurement To avoid electrical shock and or damage to the instrument disconnect circuit power and discharge all high voltage capacitors before testing diodes Set the rotary switch to PF range Press FUNC key to select t measuring mode
3. DIGITALMULTIMETER MAN USER hFE ES 0 umVA E a es el uos CONTENTS 1 GENERAL 1 2 DESCRIPTION eene 4 3 TECHNICAL SPECIFICATIONS 7 4 OPERATING INSTRUCTION 13 5 MAINTENANCE 18 1 GENERAL INSTRUCTIONS This multimeter has been designed according to IEC1010 concerning electronic measuring instruments with an overvoltage category CAT 11 1000V CAT 11 600V and pollution 2 To get the best service from this instrument read carefully this users manual and respect the detailed safety precautions 1 1 Precautions safety measures 1 1 1 Preliminary When using this Multimeter the user must observe all normal safety rules concerning protection against the dangers of electric current protection of the Multimeter against misuse For your own safety only use the test probes supplied with the instrument Before use check that they are in good condition 1 1 2 During use f the meter is used near noise generating equipment be aware that display may become unstable or indicate large errors Do not use the meter or test leads if they look damaged Use the meter only as specified in this manual otherwise the protection provided by the meter may b
4. Earth E This instrument has double insulation Fuse 500mA 250V 1 1 4 Instructions Before opening up the instrument always disconnect from all sources of electric current and make sure you are not charged with static electricity which may destroy internal components Any adjustment maintenance or repair work carried out on the meter while it is live should be carried out only by appropriately qualified personnel after having taken into account the instructions in this present manual f any faults or abnormalities are observed take the instrument out of service and ensure that it can not be used until it has been checked out If the meter is not going to be used for a long time take out the battery and do not store the meter in high temperature or high humidity environment For continue protection against fire replace fuse only with the specified voltage and current rating F500mA 250V Never use the meter unless the back cover and battery cover are in place and fastened fully 2 DESCRIPTION 2 1 Instrument Familiarization D EF DETECT Area H LCD display 3 Keypad 4 Back light key 5 Rotary switch 6 Terminals 2 2 LCD Display 3 3 4 digit 18 mm high LCD EAD EF je sns 2 3 ON OFF key This key is used to turn the meter on or off 2 4 FUNC key Selection of the dc default or ac mode and the default or mode press on
5. ance gt 50V 50Hz lt 150mm 3 2 2 DC Voltage Range Resolution Accuracy 400mV 0 1mV 0 8 of rdg 3 digits 4V 1mV 40V 10mV 400V 100 1000 1V 1 0 of rdg 3 digits Input impedance 10MQ Maximum input voltage 1000V dc or 750V ac rms 3 2 3 AC Voltage Range Resolution Accuracy 4V 1mV 40V 10mV 1 0 of rdg 3 digits 400V 100mV 750V 1V 1 2 of rdg 3 digits Input impedance 10MQ Maximum input voltage 1000V dc or 750V ac rms Frequency Range 40Hz 400Hz Response Average calibrated in rms of sine wave 3 2 4 DC Current Range Resolution Accuracy 4000uA 1 m 1 2 of rdg 3 digits 400mA 0 1mA 10A 10mA 2 0 of rdg 8digits Overload protection F 500mA 250V fuse for uAmA range Maximum input current 400mA dc or 400mA ac rms for pA and mA ranges 10A dc or 10A ac rms for 10A ranges 3 2 5 AC Current Range Resolution Accuracy 4000uA 1 D 1 596 of rdg 5 digits 400mA 0 1mA 10A 10mA 3 0 of rdg 8 digits Overload protection F 500mA 250V fuse for uAmA range Maximum input current 400mA dc or 400mA ac rms for uA and mA ranges 10A dc or 10A ac rms for 10A ranges Frequency Range 40Hz 400Hz Response Average calibrated in rms of sine wave 3 2 6 Resistance Range Resolution Accuracy 4000 0 10 E 1 2 of
6. ange expect A and EF 7 range Connect the test lead to the uAmA or 10A terminal meter alarm Set the rotary switch to the uA or mA range Connect the test lead to the 10A terminal meter alarm Set the rotary switch to the 10A range Connect the test lead to the uAmA terminal meter alarm 5 MAINTENANCE 5 1 General Maintenance To avoid electrical shock or damage to the meter do not get water inside the case Remove the test leads and any input signals before opening the Periodically wipe the case with a damp cloth and mild detergent Do not use abrasives or solvents Dirt or moisture in the terminals can affect readings To clean the terminals Turn the meter off and remove all test leads Shake out any dirt that may be in the terminals Soak a new swab with a cleaning and oiling agent such as WD 40 Work the swab around in each terminal The oiling agent insulates the terminals from moisture related contamination 5 2 Fuse replacement Before replacing the fuse disconnect test leads from any circuit under test To prevent damage or injury replace the fuse only with specified ratings Set the meter to OFF state Disconnect test leads from any inputs terminals Use a screwdriver to unscrew the three screws secured on the back cover and the battery cover then unscrew the two screws under the battery cover Separate the back cover from the top case Replace the fuse only with specified rat
7. e impaired Use extreme caution when working around bare conductors or bus bars Do not operate the meter around explosive gas vapor or dust Check the main function dial and make sure it is at the correct position before each measurement When the range of the value to be measured is unknown check that the range initially set on the multimeter is the highest position To avoid damages to the instrument do not exceed the maximum limits of the input values Caution when working with voltages above 60Vdc or 30Vac rms Such voltages pose a shock hazard When using the probes keep your fingers behind the finger guards Before changing functions disconnect the test leads from the circuit under test Disconnect circuits power and discharge all high voltage capacitors before testing resistance continuity or diode Before attempting to insert transistors for testing always be sure that test leads have been disconnected from any measurement circuits Components should not be connected to the hFE socket when making voltage measurements with test leads Before measuring current turn off power to the circuit before connecting the meter to the circuit Change the battery when the E symbol appears to avoid incorrect data 1 1 3 Symbols Symbols used in this manual and on the instrument Caution refer to the instruction manual Incorrect use may result in damage to the device or its components l
8. ings F 500mA 250V 25x20 Replace the back cover and secure by the screws 5 3 Battery replacement Before replacing the battery disconnect test leads from any circuit under test turn the meter off and remove test leads from the input terminals Use the following procedure When the battery voltage drop below proper operation range the 3 symbol will appear on the LCD display and the battery need to be replaced Set the meter to OFF state Disconnect test leads from any inputs terminals Use a screwdriver to unscrew the two screws secured on the battery cover Replace the battery with three new 1 5V batteries AAA Replace the battery cover by the two screws
9. rdg 3digits 40kQ 10Q 400kQ 100Q 4MQ 1kQ 40MQ 10kQ 2 0 of rdg 5 digits Open circuit voltage approx 0 25V Overload protection 250V dc or 250V ac rms 3 2 7 Diode and Audible continuity Test Range description Test Condition en Built in buzzer Open circuit voltage 0 5 sounds if pp resistance is less than 400 gt Display read Forward DC Current approx 1mA approx forward Reversed Voltage voltage of diode approx 1 5V 3 2 8 Temperature Overload protection 250V dc or 250V ac rms Range Resolution Accuracy 20 C to 0 C 1 C 5 of rdg 4 digits 0 C to 400 C 1 C 1 of rdg 3 digits 400 C to 1000 C 1 C 2 of rdg 3 digits Overload protection 250V dc or 250V ac rms 3 2 9 Capacitance Range Resolution Accuracy 4nF 1pF 5 096 of rdg 5 digits 40nF 10pF 3 0 of rdg 5 digits 400nF 100pF 4uF 1nF 40uF 10nF 200uF 100nF Overload protection 250V dc or 250V ac rms 3 2 10 Frequency Range Resolution Accuracy 9 999Hz 0 001 Hz 99 99Hz 0 01 Hz 999 9Hz 0 1 Hz 0 1 of rdg 1 digit 9 999kHz 1Hz 99 99kHz 10Hz 199 9kHz 100Hz gt 200kHz 100Hz Unspecified gt 200kHz Overload protection 250V dc or 250V ac rms Input Voltage range 0 6V 3V ac rms Input
10. specifications Environment conditions 600V CAT III and 1000V CAT II Pollution degree 2 Altitude lt 2000 m Operating temperature 0 40 C lt 80 RH non condensing Storage temperature 10 60 C 7096 RH battery removed Temperature Coefficient 0 1x specified accuracy C lt 18 C or gt 28 C MAX Voltage between terminals and earth ground 750V AC rms or 1000V DC Fuse Protection uAmA F 500mA 250V 25x20 Sample Rate 3 times sec for digital data Display 3 3 4 digits LCD display with max reading 3999 Automatic indication of functions and symbols Range selection automatic and manual Over Range indication LCD will display OL Low battery indication The is displayed when the battery is under the proper operation range Polarity indication displayed automatically Auto power off If there is no key or dial operation for 15 minutes the meter will power itself off to save battery consumption One minute before power off the beeper will sound 5 sounds The beeper will sound again before power off Power source 4 5V battery Dimensions 156 L x82 W x29 H mm Weight 220g Approx battery included Accessories User s manual Test leads Carry case K type thermocouple 3 2 Measurement specifications Accuracy of reading number of digits at 18 C to 28 C 64 F to 82 F with relative humidity to 80 3 2 1 No contact AC Voltage detector Sensitivity Frequency dist
11. the key the beep sounds briefly This key is operative in A and P e ranges 2 5 RANGE key Selection of the automatic default or manual mode short press 1 sec on the key the beep sounds briefly Switch from manual to autoranging mode long press 1 sec on the key the beep sounds briefly In manual mode ranges selection press successively 1 sec on the key This key is operative in V and Q ranges 2 6 HOLD key Fixes the display on the current value and memories it short press A second short press returns the meter to normal mode 2 7 REL key Selection of the Relative measurement mode press on the key the beep sounds briefly This key is operative in V A O and CAP ranges 2 8 Back light key This key is used to turn the back light on or off Press the key 22 sec the backlight will be turned on Press the key again the backlight will be turned off the key is t operative in EF range 2 9 Rotary switch This switch is used to select functions and desired ranges There are different functions and 11 ranges provided 2 10 Terminals VOHZ Cdk Terminal receiving the red lead for voltage resistance capacitance temperature frequency diode and continuity measurements COM Terminal receiving the black lead as a common reference uAmA Terminal receiving the red lead for uAmA measurement 10A Terminal receiving the red lead for 10A measurement 3 TECHNICAL SPECIFICATIONS 3 1 General
12. ture measurement thermocouples with the electriferous circuit Set the rotary switch to C range And the LCD display will show the current environment temperature Connect the red lead of K type thermocouple into the C jack and the black lead of K type thermocouple into the COM jack Contacting the object be measured with the thermocouple probe Read temperature value on the LCD display 4 9 Current measurement To avoid damage to the meter check the meter s fuse before proceeding Use the proper terminals function and range for your measurement Set the rotary switch to the 4000uA 400mA or 10A range Press FUNC key to select DCA or ACA measuring mode Connect the black test lead to the COM terminal and the red test leads to the mA terminal for a maximum of 400mA For a maximum of 10A move the red test lead to the 10A terminal Connect test leads in series with the load in which the current is to be measured Read the displayed value The polarity of red test lead connection will be indicated when making a DC measurement When only the figure OL displayed Buzzer will sound continually it indicates overrange situation and the higher range has to be selected 4 10 Misplug Alarm To avoid damage to the meter the meter provide Misplug Alarm function When the meter alarm please check the range and the terminal of the lead Following operation will bring alarm Set the rotary switch to the any r
13. voltage must be enlarged with increasing frequency under measurement 4 OPERATING INSTRUCTION 4 1 No contact AC Voltage detector A There is no auto power off function And the backlight is t operative in this range Set rotary switch to the EF 4 range Then the green LED of the LED indicator is bright Put the EF DETECT AREA close to the lead or the power socket if AC electrical voltage is present the red LED indicator which in the top of the meter will flash and the audible warning will sound and the figure 4 will be displayed on the LCD 4 2 Voltage measurement A To avoid electrical shock and or damage to the instrument do not attempt to take any voltage measurement that might exceeds 1000Vdc or 750Vac rms Do not apply more than 1000Vdc or 750Vac rms between the common terminal and the earth ground Set rotary switch to the V ACV or DCV range Press RANGE key to select manual range Connect the black and red test leads to the COM and V terminals respectively Connect the test leads to the circuit being measured Read the displayed value The polarity of red test lead connection will be indicated when making a DC measurement 4 3 Resistance measurement To avoid electrical shock and or damage to the instrument disconnect circuit power discharge all high voltage capacitors before measuring resistance Set the rotary switch to Q range Connect the black and red test leads to the COM and
Download Pdf Manuals
Related Search
DIGITALMULTIMETER digital multimeter digital multimeter tester digital multimeter for sale digital multimeter fluke digital multimeter an8201 digital multimeter with ncv digital multimeter hsn code digital multimeter smart digital multimeter price digital multimeter ht118a digital multimeter diagram digital multimeter dmm ohm digital multimeter parts and function pdf digital multimeter fluke 179