Home
PERS-2400B Installation and Operation Instructions
Contents
1. eee eee eee ene 25 vas oi ca c ada i a ata ee eee ede 26 Linear Limited Warranty 1 Product Description The PERS 2400B Console is a UL Listed supervised wireless emergency reporting product designed for personal emergency applications The table top or wall mount Console provides pushbutton emergency assistance to anyone who desires additional security and peace of mind For the visually impaired each button on the Console is molded with braille characters to identify the button s function PERS 2400B Console The Console receives signals from up to 16 Linear wireless transmitters Activating a transmitter causes the Console s digital communicator to send the appropriate alarm report to the central monitoring station via the standard telephone network In addition to the central station report audible and visual indications occur and the alarm relay energizes during an emergency activation The emergency alarm can be triggered by the large EMERGENCY button on the face of the Console or with a wireless transmitter The fire alarm can be triggered by wireless smoke alarms Activity Timer The optional activity timer can be set for 8 12 or 24 hour operation The emergency alarm will trigger automatically if the time set elapses before an activity transmitter is triggered or the Console s
2. sad 2 CONNECT RED MICROPHONE WIRE TO THIS TERMINAL CAREFULLY ALIGN PINS TO CONNECTORS ON BOTH ENDS OF BOARD MICROPHONE BE SURE THAT THE WHITE ARROWS ON AUDIO BOARD POINT TOWARD THE BATTERY AREA PRESS BOARD COMPLETELY INTO CONNECTORS NOTE AFTER THE AUDIO BOARD IS INSTALLED AND ENABLED THE CONSOLE WILL SPEAK INSTEAD OF BEEP DURING PROGRAMMING NOTE POWER MUST BE OFF AND BATTERY SHOULD BE REMOVED OR DISCONNECTED BEFORE INSTALLING THE AUDIO BOARD 7 Optional Relay Output Connections FORM A DRY CONTACT RELAY 24 VOLTS AT 1 AMP MAXIMUM 5 4 RELAY NORMALLY OPEN 3 RELAY COMMON SF CONSOLE TERMINAL BLOCK CONNECT WIRES TO TERMINALS ROUTE CABLE UNDER STRAIN RELIEF CLAMP CONNECT RED LEAD TO POSITIVE AND BLACK LEAD TO NEGATIVE BATTERY TERMINAL TURN POWER SWITCH OFF 4 BATTERY TYPE 12 VOLT 1 2 AMP HOUR FIT BATTERY INTO CONSOLE SLIDE DOWN BACK 8 Optional Remote Speaker Mic Connections VB 4B VOICE 97 E BOARD pa TERMINAL BLOCK O 5 DIALER POWER 9 4 RELAY NORMALLY OPEN O 3 RELAY COMMON 2 DIALER COMMON EXTERNAL SPEAKER 1 EXTERNAL SPEAKER NOTE REMOVE 1 JUMPER WHEN USING AN EXTERNAL SPKR NOTE NOT TESTED BY UL LINEAR MODEL RSM 1 PLUG TRANSFORMER INTO AN UN SWITCHED 117 VAC OUTLET SECURE TRANSFORMER
3. Le pr sent appareil est conforme aux CNR d Industrie Canada applicables aux appareils radio exempts de licence Lexploitation est autoris e aux deux conditions suivantes 1 l appareil ne doit pas produire de brouillage et 2 l utilisateur de l appareil doit accepter tout brouillage radio lectrique subi m me si le brouillage est susceptible d en compromettre le fonctionnement 9 near Building On Innovation Copyright 2014 Linear LLC
4. Optional Relay Output Connections a o Optional Remote Speaker Mic Si 00 02 0000002 10 Install s esseere senean apa e pia et ua aaa ae b a a E aa a d 11 Apply Power Select Dialing 12 Transmitter Installation Options gt gt ne cae gt e ra a aa ae ni li ni ali a a a ai ni 13 Installing Single Transmitters 14 Installing Multiple Transmitters 15 Testing sia aeie al 16 Erasing Pale DUNE Ss soem tent tere eee e 17 Local Programming with RA 2400 18 Telephone Connections 2 8 a e i a 19 System esas saaa ad Bea el ees al im Plein Ghar E ea Rem eee a s 20 x sys aori ee Row ere ala alta ee 0 dd at da ta 21 Audio Board aa c o e 5 22 Speakerphone Operation eee eee 23 Supervisory CONGIIONS Seen ne meme 24 Wireless Installation Tips
5. or wristband type transmitters and stationary transmitters are used for personal emergency applications When an emergency transmitter is triggered the Console sounds a two tone siren and an emergency report is sent to the central station The emergency alarm can also be triggered by pressing the Console s EMERGENCY button Fire The Model DXS 73 wireless photoelectric smoke alarms trigger the fire alarm When the fire alarm is activated the Console sounds a repeated series of three beeps and a fire report is sent to the central station Carbon Monoxide CO The Model DXS 80 wireless carbon monoxide detectors trigger the CO alarm When a carbon monoxide alarm is activated the Console sounds a repeated series of four beeps and a carbon monoxide report is sent to the central station EMERGENCY TRANSMITTERS a DXS LRP BK ey HELP DXS LRP DXS LRW DXS 65 ACTIVITY TRANSMITTERS SMOKE Activity Switch or motion triggered transmitters Models DXS 31 DXS 32 and DXS 54 can be used for ensuring human activity The DXS 54 motion detector will monitor room activity The DXS 31 and DXS 32 transmitters can be wired to a pushbutton or switch for manual activity monitoring As long as a signal is received at least once every 8 12 or 24 hours programmable an alarm will not be triggered 15 minutes before the programmed time expires the HOME indicator will start blinking and a low pitched beep will sound every ten seconds The ac
6. HOME button is pressed Voice Prompts If the optional Model VB 4B voice board is installed the Console will talk to the user The digitized voice will sound emergency fire CO Alarm timer done soon and other system operation setup and supervisory prompts from a 38 word vocabulary Audio Communications The Model VB 4B voice board supports 2 way automatic 2 way manual and 1 way listen only audio communications with central station monitoring personnel using the Console s built in high sensivity microphone and speaker Built In Speakerphone The Console can be programmed to act as a remote controlled speakerphone With the speakerphone mode enabled Model VB 4B voice board required the Console will monitor the telephone line for an incoming call Activating any emergency transmitter or the Console s EMERGENCY button while the telephone is ringing will cause the Console to seize the line and begin full duplex voice communications Activating any emergency transmitter or EMERGENCY button during the call will disconnect the line The Console will auto disconnect after 15 30 or 60 minutes programmable Transmitter Supervision Supervised transmitters regularly send status reports to the Console and low battery reports when their batteries are low When the Console receives a low battery report the TROUBLE indicator flashes If the Console fails to receive a status report from a transmitter fo
7. WITH SCREW Su 11 Apply Power Select Dialing Method TURN POWER SWITCH ON NOTE THE DEFAULT DIALING METHOD IS TONE DIALING IF REQUIRED CHANGE THE DIALING METHOD BY PRESSING AND HOLDING THE HOME amp CLEAR BUTTONS WHILE SWITCHING THE POWER ON e 7 BEEPS SOUND FOR PULSE DIALING e 8 BEEPS SOUND FOR TONE DIALING 1 PRESS CLEAR BUTTON FOR 5 SECONDS 5 BEEPS SOUND TX ADD MODE ACTIVATE TRANSMITTER 1 BEEP SOUNDS TX ADDED CONSOLE REVERTS TO OPERATE MODE NOTE IF THE CONSOLE S MEMORY IS FULL ONE LONG BEEP SOUNDS WHEN TRYING TO ADD A TRANSMITTER DXS LRW REPEAT STEPS 1 amp 2 FOR ADDITIONAL TRANSMITTERS UP TO 16 TOTAL NOTE PRESS CLEAR BEFORE TRANSMITTING TO RETURN TO OPERATE MODE WITHOUT ENTERING A TRANSMITTER 2 BEEPS SOUND WITH ACTIVITY TIMER ENABLED 3 BEEPS SOUND WITH ACTIVITY TIMER DISABLED THE CONSOLE WILL RETURN TO OPERATE MODE AUTOMATICALLY AFTER 30 SECONDS NOTE WRITE DOWN EACH TRANSMITTER S TYPE AND ZONE NUMBER WHEN THE TRANSMITTER IS ADDED THE CENTRAL STATION WILL NEED TO KNOW THE TYPE AND REPORTING ZONE FOR EACH TRANSMITTER 12 Transmitter Installation Options FOR DXS 31 STATIONARY TRANSMITTERS WHEN IT IS INSTALLED WITH THE JUMPER SET FOR DELAY THE TRANSMITTER WILL FUNCTION AS EMERGENCY WHEN IT IS INSTALLED WITH THE JUMPER SET FOR INSTANT THE TRANSMITTER WILL FUNCTION AS ACTIVITY FOR MODEL DXS 32 CUT JUMPER INSTANT TX FOR USE AS AN ACTIVITY TX SEE DXS 32 IN
8. clean the housing of the Console or the emergency transmitter s Clean units by wiping with a damp soft cloth The Console should not be located where sunlight will shine direct on it Avoid locating the Console in extremely hot or cold locations AN Important PERS Installation Warnings This electronic product and its backup battery are not to be thrown away with everyday waste It is your responsibility to dispose of electrical and electronics equipment by handing it over to a designated collection point for the recycling of waste electrical and electronic equipment W E E E The separate collection and recycling of your waste electrical and electronic equipment at the time of disposal will help to conserve natural resources and ensure that it is recycled in a manner that protects human health and the environment For more information about where you can drop off your waste equipment for recycling please contact your local city office or your household waste disposal service or the shop where you purchased the product Contents Product oc 0 6 0 00 ede cu 9 2 60 0 wa Operation Summary Ganeeece 0 a Removing Bottom based eee Console Bottom Features coat 9 6 00 Optional VB 4B Voice Board
9. of all other warranties express or implied All products returned for warranty service require a Return Product Authorization Number RPA Contact Linear Returns at 1 855 546 3351 for an RPA and other important details Important Wireless Information Linear radio controls provide a reliable communications link and fill an important need in portable wireless signaling However there are some limitations which must be observed e For U S installations only The radios are required to comply with FCC Rules and Regulations as Part 15 devices As such they have limited transmitter power and therefore limited range e A receiver cannot respond to more than one transmitted signal at a time and may be blocked by radio signals that occur on or near their operating frequencies regardless of code settings e Changes or modifications to the device may void FCC compliance e infrequently used radio links should be tested regularly to protect against undetected interference or fault e A general knowledge of radio and its vagaries should be gained prior to acting as a wholesale distributor or dealer and these facts should be communicated to the ultimate users This device complies with FCC Part 15 and Canada Rules and Regulations Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation
10. 12 OR 24 HOURS LISTEN ONLY 2 WAY MANUAL 2 WAY DUPLEX SPEAKERPHONE N O 6 24 VOLT AC DC 1 AMP MAXIMUM NEC CLASS II CIRCUITRY 24 Wireless Installation Tips WALLBOARD AND WOOD STUDS CONSTRUCTION MATERIALS WILL AFFECT RADIO RANGE 90 100 OF FULL POWER CONCRETE WITH STEEL 1 REINFORCEMENT OR METAL LATH AND PLASTER LIGHT CONCRETE OR BRICK 65 95 10 70 OF FULL POWER OF FULL POWER CENTRALLY LOCATE CONSOLE CONSOLE LOCATION WILL AFFECT RADIO RANGE TRANSMITTERS AT THE OTHER END OF THE HOUSE MIGHT BE TOO FAR AWAY 26 Linear Limited Warranty This Linear product is warranted against defects in material and workmanship for twelve 12 months This warranty extends only to wholesale customers who buy direct from Linear or through Linear s normal distribution channels Linear does not warrant this product to consumers Consumers should inquire from their selling dealer as to the nature of the dealer s warranty if any There are no obligations or liabilities on the part of Linear LLC for consequential damages arising out of or in connection with use or performance of this product or other indirect damages with respect to loss of property revenue or profit or cost of removal installation or reinstallation All implied warranties including implied warranties for merchantability and implied warranties for fitness are valid only until the warranty expires This Linear LLC Warranty is in lieu
11. ATUS PRESS CLEAR TO RETURN TO OPERATE MODE 2 BEEPS SOUND WITH ACTIVITY TIMER ENABLED e 3 BEEPS SOUND WITH ACTIVITY TIMER DISABLED THE CONSOLE WILL RETURN TO OPERATE MODE AUTOMATICALLY AFTER 3 MINUTES 17 Local Programming with RA 2400 PERFORM THE STEPS DETAILED IN THE RA 2400 PERS 2400 REFERENCE GUIDE P N 217163 TO SET UP THE RA 2400 PROGRAM TOLOCALLY THE CONSOLE CONNECT 573 THE MODEM S LINE JACK TO THE CONSOLE S LINE JACK 2 MOMENTARILY lt 5 4 BEEPS SOUND NS TEST MODE A NOTE CONSOLE WILL EXIT TEST MODE AUTOMATICALLY AFTER 3 MINUTES OR BY PRESSING THE CLEAR BUTTON WHEN RA 2400 CONNECTION TIMER STARTS COUNTING DOWN PRESS THE EMERGENCY BUTTON 4 BEEPS SOUND RA 2400 ANSWER PERFORM PROGRAMMING IN THE RA 2400 SOFTWARE THEN DISCONNECT FROM THE CONSOLE 16 Erasing Transmitters CAUTION ALL TRANSMITTERS WILL BE ERASED PRESS AND HOLD TEST BUTTON FOR 5 SECONDS 6 BEEPS SOUND ALL TRANSMITTERS WERE ERASED X S A PRESS CLEAR TO RETURN TO OPERATE MODE e 2 BEEPS SOUND WITH ACTIVITY TIMER ENABLED e 3 BEEPS SOUND WITH ACTIVITY TIMER DISABLED THE CONSOLE WILL RETURN TO OPERATE MODE AUTOMATICALLY AFTER 3 MINUTES 18 Telephone Connections LOCAL TELEPHONE TELEPHONE JACK CONSOLE WITH REAR COVER INSTALLED ROUTE CABLES UNDER STRAIN RELIEF TABS CONNECT LOCAL TELEPHONE TO CONNECT TELEPHONE THIS JACK LINE TO THIS JACK 19 System Operat
12. MITTER TO END THE PHONE CALL AND THEN PRESS ONE OF THESE BUTTONS AGAIN TO REPORT THE EMERGENCY THE AUDIO BOARD WILL END AUDIO COMMUNICATIONS WHEN EITHER THE EMERGENCY BUTTON IS PRESSED ANY EMERGENCY TRANSMITTER IS ACTIVATED THE AUTO DISCONNECT TIMER RUNS OUT NOTE TO USE THE SPEAKERPHONE MODE THE MODEL VB 4B AUDIO MODULE MUST BE INSTALLED IN THE CONSOLE 23 Supervisory Conditions TRANSMITTER LOW BATTERY TROUBLE WHEN A TRANSMITTER SENDS A LOW BATTERY SIGNAL THE CONSOLE S TROUBLE INDICATOR WILL BLINK SLOWLY TRANSMITTER SUPERVISORY TROUBLE IF A TRANSMITTER PROGRAMMED AS SUPERVISED FAILS TO REPORT STATUS IN A 24 HOUR PERIOD THE CONSOLE S TROUBLE INDICATOR WILL LIGHT CONSOLE BACKUP BATTERY TROUBLE THE CONSOLE WILL TEST ITS BACKUP BATTERY EVERY 8 HOURS IF THE BATTERY TESTS LOW THE POWER INDICATOR WILL BLINK SLOWLY WHILE THE CONSOLE CHARGES THE BATTERY WHEN TROUBLE EXISTS THE CONSOLE WILL BEEP EVERY HOUR UNTIL CLEARED 2 BEEPS CONSOLE LOW BATTERY 3 BEEPS TRANSMITTER SUPERVISORY 4 BEEPS TRANSMITTER LOW BATTERY ERROR LOW SENSOR BATTERY THE CONSOLE WILL ee TROUBLE AND OR 30 DAY STATUS TO THE CENTRAL STATION IF ENABLED IN THE COMMUNICATOR PROGRAMMING NOTE THE CONSOLE WILL ANNOUNCE THE SUPERVISORY CONDITIONS WITH THE OPTIONAL MODEL VB 4B VOICE BOARD INSTALLED THE VOICE CAN BE DISABLED THROUGH CLEARING TROUBLE INDICATIONS PROGRAMMING PRESS THE CLEAR BUTTON TO STOP TROUBLE INDICA
13. PERS 2400B PERSONAL EMERGENCY REPORTING SYSTEM UL LISTED DX INSTALLATION amp OPERATION INSTRUCTIONS Linear Building On Innovation USA amp Canada 800 421 1587 amp 800 392 0123 760 438 7000 Toll Free FAX 800 468 1340 www linearcorp com Be sure and test the system weekly Instruct the end user regarding the importance of periodically testing the system IMPORTANT For telephone connection connect the LINE jack to the household telephone line wall jack as described in the installation instructions The Console will not be able to report over the telephone if this connection is not made The Console must be connected to a Managed Facilities Voice Network MFVN that will remain in operation during local power outages The Console must be located centrally in the installation area relative to where the personal emergency transmitter s will be carried and or activated Locating the Console adjacent to large metal objects may change or reduce the effective radio range of personal emergency transmitters used with the Console Electrical interference can reduce the effective radio range of the Console Do not operate any electrical appliances or electrical noise generating devices fluorescent lamps motors etc near the Console The Console should be kept free of dust and moisture Do not use ammonia benzene thinner or similar solvents or abrasive powder to
14. SPEAKERPHONE MODE PRESS DURING SPEAKERPHONE MODE TO DISCONNECT CLEAR BUTTON STOPS ALARM e ADDS CANCEL TO AN ALARM REPORT IN PROGRESS PRESS IMMEDIATELY AFTER EMERGENCY TO PREVENT REPORT CLEARS INDICATORS STOPS TROUBLE BEEPER PRESS FOR 5 SECONDS TO ADD A TRANSMITTER HOME BUTTON PRESS TO RESET ACTIVITY TIMER PRESS FOR 5 SECONDS TO TURN ACTIVITY TIMER OFF IF ACTIVITY TIMER IS OFF PRESS FOR HOME INDICATOR LIGHTS WHEN ACTIVITY TIMER IS ON BLINKS SLOWLY WHEN LESS THAN 15 MINUTES REMAIN ON THE ACTIVITY TIMER BLINKS QUICKLY WHEN THE ACTIVITY TIMER HAS EXPIRED SENDING INDICATOR e NORMALLY OFF FLASHES WHEN CONSOLE IS PLACING A CALL 5 Console Bottom Features 16 VAC 1 25 AMP PLUG IN TRANSFORMER 5 SECONDS TO TURN ACTIVITY TIMER ON 4 HOME BUTTON COVER ADHESIVE BACKED PLATE HIDE THE HOME BUTTON IF THE ACTIVITY TIMER IS NOT USED 12 VOLT 1 2 AMP HOUR BACKUP BATTERY EXTERNAL SPEAKER RELAY OUTPUT AND DIALER POWER TERMINALS 1 AMP 2AG VB 4B VOICE BOARD OPTIONAL BATTERY FUSE HIDDEN LOCAL PHONE JACK TELEPHONE LINE JACK SWITCH BUTTON 4 Removing Bottom Cover TO ACCESS THE INSIDE OF THE CONSOLE PRESS THE TWO LOCKING TABS IN AND REMOVE THE CONSOLE S BOTTOM COVER REMOVE PRESS FIT MICROPHONE INTO ROUND MOUNTING HOLE CONNECT BLACK MICROPHONE WIRE Vii TO CENTER TERMINAL
15. STALLATION INSTRUCTIONS 14 Installing Multiple Transmitters ADDS MULTIPLE TRANSMITTERS A xX LBZ 2 PRESS TEST BUTTON AGAIN 5 BEEPS SOUND ADD TX MODE NOTE EACH TIME THE TEST BUTTON IS PRESSED IN THE ADD TX MODE THE CONSOLE WILL BE READY TO INSTALL A TRANSMITTER IN THE NEXT AVAILABLE SENSOR ZONE LOCATION IF THE VB 4B VOICE BOARD IS INSTALLED THE CONSOLE WILL ANNOUNCE THE SENSOR ZONE LOCATION NUMBER ACTIVATE TRANSMITTER 1 BEEP SOUNDS TX ADDED NOTE IF THE CONSOLE S MEMORY IS FULL ONE LONG BEEP SOUNDS WHEN TRYING TO ADD A TRANSMITTER REPEAT STEPS 2 amp 3 FOR ADDITIONAL TRANSMITTERS UP TO 16 TOTAL PRESS CLEAR TO RETURN TO OPERATE MODE e 2 BEEPS SOUND WITH ACTIVITY TIMER ENABLED 3 BEEPS SOUND WITH ACTIVITY TIMER DISABLED THE CONSOLE WILL RETURN TO OPERATE MODE AUTOMATICALLY AFTER 3 MINUTES NOTE WRITE DOWN EACH TRANSMITTER S TYPE AND ZONE NUMBER WHEN THE TRANSMITTER IS ADDED THE CENTRAL STATION WILL NEED TO KNOW THE TYPE AND REPORTING ZONE FOR EACH TRANSMITTER DXS LRW 15 Testing Transmitters O Geer N 2 ACTIVATE EACH OF THE CONSOLE S TRANSMITTERS ONE AT A TIME gt COUNT THE NUMBER OF BEEPS THAT THE CONSOLE SOUNDS WHEN THE TRANSMITTER IS ACTIVATED 1 BEEP 2 BEEPS TX HAD ALARM 3 BEEPS TX MISSED STATUS 4 BEEPS TX HAS LOW BATTERY NOTE WITH THE MODEL VB 4 VOICE BOARD INSTALLED THE CONSOLE WILL ANNOUNCE THE TRANSMITTER ST
16. TORS AND SOUNDERS NOTE THE TROUBLE CONDITION WILL LIKELY OCCUR AGAIN UNTIL THE PROBLEM IS FIXED 25 Specifications CODING FORMATS DX CODE 24 BIT A1D PPM DXS CODE 24 BIT A1D PPM POWER REQUIREMENTS PRIMARY SUPPLY BACKUP SUPPLY NORMAL OPERATING CURRENT ALARM OPERATING CURRENT BACKUP OPERATION DURATION BATTERY LIFE EXPECTED BACKUP SUPPLY OPERATING CURRENT RF CHARACTERISTICS RECEIVER TYPE RF SENSITIVITY RADIO FREQUENCY MAXIMUM RANGE COMMUNICATOR COMMUNICATOR FORMATS DIALING DIALING DELAY REMOTE ACCESS PASSWORD ACCOUNT NUMBER LENGTH PRIMARY TELEPHONE NUMBER SECONDARY TELEPHONE NUMBER SUPERVISORY TELEPHONE NUMBER CONSOLE STATUS REPORT CONSOLE OPERATING TEMPERATURE EMERGENCY ALARM DURATION ACTIVITY TIMER PERIOD AUDIO RELAY OUTPUT 1 048 567 CODES 1 048 567 CODES 16 VAC 1 25 AMP PLUG IN TRANSFORMER 12 VOLT 1 2 AMP HOUR BATTERY 80 mA 120 mA 32 HOURS MINIMUM 3 YEARS 32 DUAL DIVERSITY SUPERHETERODYNE 100 dBm TYPICAL 315 Mhz 400 FEET LINE OF SIGHT OPEN RANGE UL LISTED FOR 150 4 BY 2 GENERAL OR POINT TO POINT ADEMCO CONTACT ID UL TESTED WITH SURGARD SGMLRG DG CENTRAL STATION RECEIVER TONE OR PULSE 4 0 OR 15 SECONDS 6 DIGITS NOTE THE INSTALLER MUST DIGITS VERIFY COMPATIBILITY 20 DIGITS BETWEEN THE PERS 2400B AND 20 DIGITS THE UL LISTED DIGITAL ALARM 20 DIGITS COMMUNICATOR RECEIVER OPTIONAL 1 7 OR 30 DAY REPORT 32 100 F 0 50 C 1 30 MINUTES 8
17. TURN THE ACTIVITY TIMER ON NOTE THE ACTIVITY TIMER CAN BE ENABLED FOR 8 12 OR 24 HOURS OR DISABLED BY 4 PROGRAMMING NOTE TO TURN THE ACTIVITY TIMER OFF PRESS THE HOME BUTTON FOR FIVE SECONDS 2 ACTIVITY TIMER RUNNING THE HOME INDICATOR WILL LIGHT SHOWING THAT THE ACTIVITY TIMER 18 ENABLED TIME RUNNING OUT THE HOME INDICATOR WILL BLINK amp A SHORT BEEP SOUNDS EVERY 10 SECONDS WHEN LESS THAN 15 MINUTES OF TIME REMAIN RESETING ACTIVITY TIMER THE SUBSCRIBER NEEDS TO PRESS THE HOME BUTTON OR gt TRIGGER AN ACTIVITY TRANSMITTER BEFORE THE eS TIMER EXPIRES TO PREVENT AN INACTIVITY REPORT gt PRESSING THE HOME BUTTON RESTARTS THE TIMER SS 22 Speakerphone Operation PROGRAM THE CONSOLE TO ENABLE SPEAKERPHONE MODE NOTE SPEAKERPHONE MODE CAN ONLY BE USED ON INCOMING CALLS AND WILL NOT FUNCTION WHEN THE CONSOLE IS OPERATING FROM BACKUP BATTERY POWER ATTEMPTING TO ANSWER WHILE THE CONSOLE IS ON BACKUP POWER WILL CAUSE AN EMERGENCY ALARM WHILE THE TELEPHONE IS RINGING ACTIVATING AN EMERGENCY TRANSMITTER OR PRESSING THE EMERGENCY BUTTON WILL SEIZE THE TELEPHONE LINE THE AUDIO BOARD WILL BEGIN 2 WAY FULL DUPLEX MODE FOR AUDIO COMMUNICATIONS WARNING THE CONSOLE WILL NOT BE ABLE TO REPORT AN EMERGENCY WHILE THE SPEAKERPHONE MODE IS ACTIVE NOTE TO REPORT AN EMERGENCY WHEN THE SPEAKERPHONE IS IN USE PRESS EITHER THE EMERGENCY BUTTON OR THE BUTTON ON AN EMERGENCY TRANS
18. ion CONSOLE STANDING BY PRESS AND MOMENTIARLY ACTIVATE HOLD EMERGENCY EMERGENCY TRANSMITTER BUTTON PRESS TRANSMITTER BUTTON FOR AT LEAST 2 SECONDS IS PRESSED CENTRAL STATION SENDING LIGHT 227 4 REPORT IS COMPLETE FLASHES DURING OR SIREN TIME EXPIRES COMMUNICATION CONSOLE SIREN SOUNDS IN ALARM he UNTIL CLEAR BUTTON PRESS CLEAR TO STOP SIREN ADDS CANCEL TO ALARM REPORT IN PROGRESS 21 Audio Board Operation 9 PROGRAM THE CONSOLE FOR THE DESIRED AUDIO MODE LISTEN ONLY e 2 WAY MANUAL 2 WAY FULL DUPLEX 2 AFTER THE CENTRAL STATION OPERATOR ACKNOWLEDGES THE COMMUNICATOR S REPORT THE CONSOLE WILL STOP ITS SIREN AND SWITCH TO THE AUDIO MODE FOR 90 SECONDS CENTRAL STATION OPERATOR USE THESE KEYS ON A TELEPHONE SET CONNECTED TO THE CENTRAL STATION LINE TO CONTROL THE AUDIO MODULE nie PRESS 9 TO MODES DISCONNECT THE CALL MANUAL AUDIO MODE PRESS 1 TO TALK 2 WAY PRESS 3 LISTEN THE 1 AND 3 KEYS ARE NOT USED IN LISTEN ONLY AUDIO MODE THE 1 AND 3 KEYS CAN BE USED IN FULL DUPLEX MODE THE MODULE WILL SWITCH TO 2 WAY MANUAL MODE PRESSING 8 RESTORES FULL DUPLEX MODE PRESSING ANY KEY OTHER THAN 9 WILL EXTEND THE AUDIO TIME 90 MORE SECONDS NOTE TO USE THE AUDIO MODES THE MODEL VB 4B AUDIO MODULE MUST BE INSTALLED IN THE CONSOLE 20 Activity Timer ENABLING THE ACTIVITY TIMER PRESS THE HOME BUTTON FOR 5 SECONDS TO
19. r a period of 24 hours the TROUBLE indicator will light All supervisory conditions can sound a local annunciation and be reported to the central station Digital Communicator The Console s digital communicator can route calls to three telephone numbers primary secondary and supervisory General reporting codes and individual sensor reporting codes are programmable for the 4x2 format Alternately Ademco Contact ID may be selected for the communicator reporting format Power Supply Powered by a low voltage plug in transformer the Console has provisions for a rechargeable backup battery for operation during AC power outages A power switch allows for out of service storage of the Console without discharge of the battery The battery is recharged and supervised by the Console If the backup battery becomes low the POWER light will flash and the condition can be reported to the central station Programming The Console is programmed using the RA 2400 remote access software available at Linear s Web site www linearcorp com Refer to the software s detailed instruction manual and built in help file for programming details 2 Operation Summary A variety of Linears DXS Format and DXT Format transmitters can be used with the Console NOTE DXS Format transmitters are supervised DXT Format transmitters are not supervised Transmitters can be assigned to the following four functions Emergency Portable pendant belt clip
20. tivity timer can be reset with a signal from one of the activity transmitters or by pressing the HOME button on the Console Failure to reset the activity timer within the programmed time period will cause the Console to sound the two tone emergency siren and send an inactivity report to the central station The activity timer can be turned on or off at the Console or through programming Automatic Full System Test The Console can be programmed to perform a full system test daily weekly or monthly The automatic full system test can also be disabled As long as all system components are operational the system test report will be sent at the programmed interval The full system test report will NOT be sent if any system component transmitter Console phone line is not fully functional DXS LRC 7 DXS 31 CARBON MONOXIDE DXS 31 DXS 32 DXS 54 DXS 73 UP TO 16 TRANSMITTERS TOTAL CAN BE USED WITH EACH CONSOLE PERS 2400B CONSOLE PERS 2400B Compatible Transmitters 3 Front Panel Features TROUBLE INDICATOR NORMALLY OFF LIGHTS WHEN ANY TRANSMITTERS ARE MISSING SUPERVISORY BLINKS SLOWLY WHEN ANY TRANSMITTERS HAVE A LOW BATTERY POWER INDICATOR e LIGHTS WHEN AC IS PRESENT BLINKS SLOWLY WHEN BATTERY IS CHARGING BLINKS QUICKLY WHEN AC IS ABSENT CONSOLE ON BATTERY POWER OFF IN TEST AND SETUP MODES EMERGENCY BUTTON PRESS AND HOLD TO TRIGGER THE EMEREGNCY ZONE PRESS DURING RING FOR