Home

Electronic Code Lock SL2000E v1.2 Rev.A

image

Contents

1. INSTALLER Code All digits are 2 2222 the length of the code depends on the C10 parameter entered during Memory Reset procedure USER Code no 01 All digits are 3 3333 the length of the code depends on the C9 parameter entered during Memory Reset procedure USER Code 02 55 All USER codes no 02 55 are blank they doesn t exist roger Page 6 of 11 Security Locks SL2000E v1 2 EN Rev A doc 2011 09 01 Installation The SL2000 code lock should be mounted near the supervised door on a vertical piece of supporting structure Assure that the surface beneath of the controller s rear panel is flat and smooth Disconnect power supply before making any electrical connections Once installed and electrically connected the unit has to be properly programmed When forgotten MASTER and INSTALLER codes can be reprogrammed through Memory Reset procedure The code lock must be supplied form reliable power supply calculate the adequate wire gauge to guarantee that the voltage dropout between the power supply and the DC input of SL2000 will not exceed 1V in the worst case It is recommended to supply door release device e g door strike or magnet lock and SL2000 from separate power supply but when both code lock and door release device are supplied from the same power source you must use separate pairs of cable to supply each of them Always add the silicon diode e g 1N400x series in parallel to door release de
2. for a time defined by C3C4 value The triggering of the Door Relay output is indicated by LED OPEN green this LED lights up as long as Door Relay output is on Note If the option Disable Access in Armed Mode is enabled the activation of the Door Relay output may occur only when the unit operates in the Disarmed mode Status Output When the SL2000 is in Armed mode this output is not active and remains in high resistance condition When code lock switches to Disarmed mode the Status output shorts to supply minus GND and stay in this condition as long as the SL2000 operates in the Disarmed mode The maximum current sink by this output is internally limited to 1 0A the maximum voltage applied to it must not exceed 16V DC The Status output can be used for rearming of an alarm zone or to control any other device or system which requires on off method of control Note The arming and disarming of a code lock can be carried out by MASTER code only Aux Output Normally this output remains in high resistance state if triggered it shorts to supply minus GND The Aux output has been designed to indicate two situations e Door Bell event e Door Alarm event Whenever the Bell key is pressed for a moment or the key is pressed and held down longer then half a second the Aux output goes steady on shorts to supply minus the Aux output remains in this condition as long as the Bell or key is being pressed The Aux output can be also act
3. series of two beeps Old MASTER Code New MASTER Code This command erases the old MASTER code and program new MASTER code If command is successfully accomplished the unit generates three series of two beeps Note Whenever you re program MASTER or INSTALLER code remember that new code programmed into a unit must have the same length as the old one Bell Key A single short press of this key activates the Aux output and internal buzzer for atime of 2 3 seconds The indication on Aux output and buzzer is continued for entire time as long as Bell key is being pressed Normally it marks the end of a code but when pressed separately for a time longer the 0 5s it acts in the same way as Bell key Programming of the USER Codes The SL2000 enables programming of up to 55 different USER codes The USER codes can be managed added deleted changed only in the Installer Programming mode In order to program the USER codes you must first enter the Installer Programming mode and the you have access to the programming commands listed below 0 1 code Programming of the USER code no 1 0 2 code Programming of the USER code no 2 0 3 code Programming of the USER code no 3 es CUC CCUG etc 5 5 code Programming of the USER code no 55 0 0 Delete all USER codes 9 9 code Deletes the code entered in square bra
4. Electronic Code Lock SL2000E v1 2 Rev A Features Door Relay output Status transistor output Aux transistor output Door Contact input Exit Button input INSTALLER code for programming MASTER code for arming disarming USER codes for door opening Door Alarm indication Option Timed Lock out after three wrong codes Option Access only when Disarmed Programmable length of codes User indexing for easy administration of codes Nonvolatile memory Keypad with backlight Door Bell key Three LEDs and buzzer Tamper contacts Outdoor operation IP65 roger Security Locks SL2000E v1 2 EN Rev A doc 2011 09 01 Introduction The SL2000E electronic code lock is designed for operation as a indoor outdoor stand alone door access control unit The device is equipped with one relay output two transistor outputs and two NO inputs All codes and parameters configuring the device s operation are stored in nonvolatile memory Functional Description Note The C1 C2 C10 parameters which appear in this manual refer to configuration settings programmed to the SL2000 during Memory Reset procedure see section Configuring the SL2000 later in this document Door Relay Output This output is designed to control a door locking device e g door strike or magnetic lock Each time the valid USER code is entered the SL2000 starts counting time delay specified by C1C2 parameters and after it elapses the relay output is activated
5. TALLER codes enter 0 3 default 1 O Both codes are 4 digits long i Both codes are 6 digits long 2 Both codes are 8 digits long 3 Both codes are 10 digits long If an illegal operation occur during Memory Reset the device will signal an error long beep and will return to the beginning of the programming so you can start to enter the C1 C10 digits once again The Memory Reset procedure automatically comes to an end when the last C10 digit is entered The device stores the configuration as well as all codes in a nonvolatile memory which can be reprogrammed whenever required After the Memory Reset procedure comes to an end all codes are set to default values see section Default Codes Example The following digits C1 C10 were entered during the Memory Reset procedure O 1 O 2 3 3 1 0 2 3 This sequence sets the following options e Open Delay 01 second e Lock Activation Time 02 seconds e Time for Door Closing 33 seconds e Reprogramming of the MASTER code disabled e Reprogramming of the INSTALLER code enabled e Option 1 Timed Lock out option off e Option 2 Disable Access in Armed Mode option off e USER codes 6 digits e MASTER and INSTALLER codes 10 digits Default Codes After the Memory Reset is accomplished the following codes are automatically programmed into a unit MASTER Code All digits are 1 1111 the length of the code depends on the C10 parameter entered during Memory Reset procedure
6. age 3 of 11 Security Locks SL2000E v1 2 EN Rev A doc 2011 09 01 USER Codes These codes are used for activation of the Door Relay output Each time a valid USER code is entered the SL2000 starts counting C1C2 time delay and then when it passes by the unit activates Door Relay output The Door Relay output is activated for time defined by C3C4 settings The USER codes can be 2 8 digits long Note The SL2000 enables programming of maximum 55 USER codes each of them can open the door Commands Commands can be entered during normal working time of a SL2000 code lock and doesn t require entry to the programming mode USER Code Whenever a valid USER code is entered the code lock generates two beeps and then starts count C1C2 time delay After it passes by the SL2000 activates Door Relay output for time defined by C3C4 settings During this time door locking device is energized and user can open the door MASTER Code Each time the MASTER code is entered the SL2000 changes its arming mode switches from Armed to Disarmed mode or in reverse direction INSTALLER Code After this command code lock generates two beeps and enters the Installer Programming mode In this mode installer can program the USER codes to a unit Old INSTALLER Code New INSTALLER Code This command erases the old INSTALLER code and program new INSTALLER code If command is successfully accomplished the unit generates three
7. ckets Page 4 of 11 roger Security Locks SL2000E v1 2 EN Rev A doc 2011 09 01 Exit from the Installer Programming mode When the code lock accepts the new USER code it generates two series of two beeps Any attempt to program a USER code which already exists in memory or to program it with a code length bigger then programmed during Memory Reset will cause the programming error signalled by the long acoustic beep Configuring the SL2000 Memory Reset In order to configure the SL2000 you must perform the Memory Reset and then enter sequentially 10 digits called C1 C10 which will configure the unit for individual installation After the Memory Reset the entire contents of the code lock memory is erased including all codes and initialized with Default Factory settings These values In order to perform Memory Reset do the following steps e Turn off the power supply e Connect Reset wire Brown Yellow to supply plus e Turn on the power supply e Wait till the moment when device will sound three series of two beeps this signal indicates that SL2000 erased memory and restored default configuration settings e Disconnect Reset wire Brown Yellow from supply plus e Enter sequentially ten digits C1 C10 e After the last digit is entered the code lock generates the three series of two beeps then ends the Memory Reset procedure and switches to normal working mode Meaning of the configuration paramete
8. e humidity 10 95 non condensing Connection Terminals Assignments p Wrecotour Reser a Output Status transistor output max current sink 1 0A 16V DC Ee Aux transistor output max current sink 1 0A 16V DC TMP A Tamper contact A NC max 50mA 24V TMP B Tamper contact B NC max 50mA 24V Exit Button Exit Button input NO type Door Door Contact White Green Door Contact input NO type 1 5A 24V DC AC LED a Pink NO input when shorted with supply minus LED SYSTEM becomes active roger Page 10 of 11 Security Locks SL2000E v1 2 EN Rev A doc 2011 09 01 Ordering Information em pen SL2000F Dark grey plastic enclosure screw connection terminals indoor installation only SL2000F VP Vandal proof metal front cover and keys silver color pig tail connection cable outdoor installation available Product History SL2000F v1 0 N A 16 11 2009 Initial release of the product SL2000F VP v1 0 N A 16 11 2009 Initial release of the product The symbol of a crossed through waste bin on wheels means that the product must be disposed of at a separate collection point This also applies to the product and all accessories marked with this symbol Products labeled as such must not be disposed of with normal household waste but should be taken to a collection point for recycling electrical and electronic equipment Recycling helps to reduce the consumption of raw materials thus protecting the environment Contact Ro
9. ger Sp j 82 400 Sztum Gosciszewo 59 Tel 48 55 272 01 32 Fax 48 55 272 01 33 Technical support PSTN 48 55 267 01 26 Technical support GSM 48 664 294 087 e mail biuro roger pl roger Page 11 of 11
10. ivated when Door Alarm is active The code lock indicates the Door Alarm through pulsed modulation of the Aux output Thanks to this feature steady or pulsed output operator may distinguish the Bell signal from the Door Alarm The maximum current sink by this output is internally limited to 1 0A the maximum voltage applied to it must not exceed 24V DC Normally the Aux output is used to trigger some kind of warning device e g alarm siren or buzzer Note The Door Alarm has higher priority then the Door Bell event As a result when two of those events occur simultaneously only the Door Alarm is indicated on the output line Exit Button Input Triggering of this input activates Door Relay output on the same rules as the entry of a valid USER code The Exit Button is a NO type it becomes triggered when shorted to supply minus GND Door Contact Input This input is dedicated for a connection of a door open sensor When input is open or left unconnected the code lock assumes that door is closed when input is shorted to supply minus GND the SL2000 assumes that door is open Page 2 of 11 roger Security Locks SL2000E v1 2 EN Rev A doc 2011 09 01 Note If you are not going to use a door open sensor leave the Door Contact input unconnected Without a door open sensor the SL2000 will not indicate the Door Open alarm LED System Input This input is dedicated to control the LED SYSTEM orange shorting this input with supply minus ligh
11. o this option the MASTER user can disable access to the room by switching the unit to Armed mode and vice verso he can enable access to controlled door by switching the code lock to Disarmed mode The SL2000 can be switched between Armed and Disarmed modes through the MASTER code only Arming and Disarming of the Code Lock In normal operation mode the SL2000 may work either in the Armed or Disarmed mode The Armed mode is Signalled by LED ARMED red whereas the Disarmed mode is signalled by LED DISARMED green The actual operating mode of a lock is also indicated on the Status output line which when active indicates that unit is Disarmed The switching between Armed and Disarmed modes can be carried out by MASTER code only Whenever code lock switches to Disarmed mode is generates two series of two beeps whereas when switches to Armed mode it generates two beeps only Codes The SL2000 offers three types of codes e MASTER Code e INSTALLER Code e USER Codes Each type of code is designed for individual purpose The length of each code can be programmed during Memory Reset procedure The entry of each code must be followed by the key which is used to mark the end of a code MASTER Code The MASTER code is used to switch the SL2000 between Armed and Disarmed modes it can be 4 10 digits long INSTALLER Code The INSTALLER code is required to enter the Installer Programming mode it can be 4 10 digits long roger P
12. rs C1 C10 C1iC2 Open Delay specifies the time delay from a moment when access is granted to a moment when Door Relay will be activated It can be programmed from 00 to 99s default 04 C3C4 Lock Activation Time specifies the time for which Door Relay will be activated when access is granted It can be programmed from 00 to 99s default 04 C5C6 Time for Door Closing specifies the time within which door must be closed It can be programmed from OO to 99s the 00 value sets unlimited time for closing default 09 C7 Enables or disables of reprogramming of the MASTER and INSTALLER codes enter 0 3 default 0 3 Disabled Disabled Note If reprogramming of a given code is disabled the SL2000 allows you a single attempt only to program of the given code Once the code is programmed you will not be able to change it unless the Memory Reset is carried out Use this function to disable the end user to change your MASTER and INSTALLER code C8 Enabling and disabling Option 1 and Option 2 enter 0 3 default 0 S Toon Toon a a areata Option 1 Timed Lock out Page 5 of 11 roger Security Locks SL2000E v1 2 EN Rev A doc 2011 09 01 Option 2 Disable USER Codes When in Armed Mode C9 Defines the length of the USER codes enter 0 3 default 1 0 USER codes are 2 digits long 1 USER codes are 4 digits long 2 USER codes are 6 digits long ome USER codes are 8 digits long C10 Defines the length of the MASTER and INS
13. ts up LED SYSTEM The LED SYSTEM can be use to any purpose required by installer e g to indicate actual status of the alarm system Door Open Alarm The Door Open alarm will occur when e door has been opened without entering of a valid USER code e door has been opened without pressing of the Exit Button e door has not been closed within C5C6 time from the moment when door locking device was deactivated The Door Open alarm is indicated by pulsed activation of the Aux output which is accompanied by a continues acoustic signal generated by the internal buzzer Pressing any key will cease the acoustic signal however this does not cancel the alarm indication on Aux output The indication on the Aux output disappears when door becomes closed or automatically after 60 seconds from the moment when alarm arose Option 1 Timed Lock out If this option is enabled the lock disables the keypad for 60 seconds after three attempts of entry of incorrect code After this time the SL2000 re enables the keypad and is ready to accept new keypad s entries The end of 60 seconds lock out time is indicated by two series of two beeps Option 2 Disable Access in Armed mode If this option is enabled the SL2000 grants access to a room only when it operates in Disarmed mode With this option active the access to the controlled door will be disabled for both all USER codes and Exit Button unless the SL2000 will be switched to Disarmed mode Note Thanks t
14. vice locate diode as close as possible to door release and as far as possible from the code lock It is forbidden to supply the door release device directly from the DC input terminals of a code lock Do not attempt to use Door Relay output for switching of a voltages higher then 24V DC AC Page 7 of 11 roger Security Locks SL2000E v1 2 EN Rev A doc 2011 09 01 SL2000E v1 2 Typical Wiring Diagram Power Supply Reserve Battery 12V GND Black Z Signalling Device e g siren 5 7 AUX Output Brown STATUS Output Green Tamper Contact A Grey Bi LED SYSTEM control signal Relay NC Grey Pink Relay COM White Relay NO Violet Door Contact Input White Green Exit Button Input Blue Reset Brown Yellow i Door Contact F1 Bell Button Door Lock fi Exit Button cdr179p4 roger Page 8 of 11 Security Locks SL2000E v1 2 EN Rev A doc 2011 09 01 SL2000E v1 2 Code Lock Views and Installation Diagram LED OPEN amp LED STATUS Aj LED SYSTEM A Page 9 of 11 roger Security Locks SL2000E v1 2 EN Rev A doc 2011 09 01 Technical Specification Supply 10 16 VDC Current consumption Avg 25 mA 12V DC Max 80 mA 16V DC with relay output active Anti sabotage protection Tamper NC contact 50mMA 24V Environmental Class according to EN 50131 Class IV Outdoor General 1 Temp 25 C 60 C Relativ