1. AC 110v 220v OUTPUT 12V 6000MA 6 Serial communication interface RS 232 full serial interface mode with assign date transport line 7 Operation Circumstance Operation temperature 10 C 60 C Storage temperature 20C 70 C Operation humidity 45 95 Atmosphere pressure 86 106Kpa Environment noise 60DB Transmitting Power 2W sensitivity lt 104dbm Antenna Amplifying gt 1 5db Dialing frequency 450Hz Hanging voltage 45V Picking carrent 30mMA 41mA Notice e Please read the rules carefully It is dangerous or will break the law against the rules e Masking Please make sure there is no masking to wireless frequency signal before using e Pay attention to the Traffic Security Do not use the phone which connects to the FWT when you are driving e Disturbance Affect by disturbance leads up to affect the phone capability like other mobile phone e Explosion Zone Do not use the FWT in explosion zone or the place with the sign of closing the wireless receive and dispatch unit e Latent explosive circumstances Do not use the unit in latent explosive areas e g Gas station Flammable liquid Gas transportation vehicle warehouse etc e Children Do not let children play with the FWT Perhaps they will be stabbed by antenna or stab Page 6 of 9 others They may destroy the interface or make wrong call to add the charge e The eligible maintenance Install and maintain by eligible maintenance people Please con
2. and supply Dialing tone DTMF Dialing FSK DTMF Caller ID Bell signal Polarity reversal The RJ 11 socket which connects the phone or the payphone Antenna socket FME IP usage switch lt K X gt lt X X X X X Working state indicator X Signal Strength indicator 2 Configuration and installation 1 4 8 16 32 port Gateway package list X Fixed Wireless Terminal mainframe 1pcs X 850 1900 1800 900MHz antenna FME 1set 4 8 32pcs X Users Guide 1pcs X Data cable optional 1pcs 2 Installation Steps The equipment adopts digit GSM network communication mode it need effective SIM card Install the Fixed Wireless Terminal in a suitable place Page 3 of 9 2 Turn off the power at the back of the unit 3 Install effective SIM card a Take off the screw of the SIM card cover at the back of the unit b Open the SIM card cover c Move the SIM card clamp according to the arrow d Lift the SIM card clamp to insert the SIM card e Press the SIM card clamp and move it to firm Close the SIM card cover then wring the screw 4 Input the antenna into the socket Plug the end of the conjunction line of the phone payphone into the RJ 11 socket of the FWT and connect the other end to the phone payphone Plug the 220v 110v socket and connect the other end to the power socket at the back of the FWT 7 Turn on the power at the back of the FWT You can operate the FWT after installing and passing the setting of
3. signal In use light it lights when start the unit and cannot connect to the gsm module It lights when you pick off the hand of a phone 4 3 Dialing call When signal strength indicator displays to receive strength signal and the working indicator in the light state pick off the handset which connects to the FWT you can hear the dialing tone if it connects to the payment the payphone will display the dialing number and the charger when it get through It will give the payphone or voip gateway a ACCURACY reverse polarity 4 4 Incoming call The phone will ring when call comes pick off the handset to talk with the other side 4 5 How to use payphone Please refer to the payphone manual 4 6 Parameter Set You can set through outside phone keyboard input 888999 to enter into setting and input 00 0 to drop out The setting directive and format is as follows a long tone means setting successfully two short tone means error setting hang the phone and pick off again to set again 5 Technology Index 1 Frequency ranges GSM 900 1800MHZ GSM850 1900MHZ option 2 SIM Card It support 3VG SIM card 3 Phone interface Supply RJ 11 Phone Interface Hanging voltage 45V Picking off voltage 30mMA 41mA Dialing tone Frequency 450Hz Ring voltage 75V 25HZ 1second ring 4seconds silence 4 Antenna interface Antenna amplifying gt 1 5DB Page 5 of 9 Sensitivity lt 104DBM Transmitting powers3W 5 Adapter interface INPUT
4. the system initialization of the network supplier 3 Function 4 8 16 32 port GSM Gateway is wireless equipment which is based on wireless module SIM340 or Q2403 it communicates clearly and has no noise with insider backup battery and is convenient and durable The function of the FWT is as follows 1 Supply two set extensions to connect 2 Incoming call display 3 Set local code IP access code and special number Set limiting to dial national long distance call mobile 4 phone call and local call set using IP or not 6 Lock phone and telecom operator 7 Lock card automatically lock card with random PIN code or fixed PIN code 4 Operation 4 1 Turn on Turn on the power the unit need about 2 minutes to load initialize date automatically and search network in the period the working indicator keep on lighting you can listen to the dialing tone after picking up the handset the indicator will flash at 1Hz frequency In Page 4 of 9 the process of turning on the phone when you set locking unit lock card lock network the unit will check automatically according to the setting if it fails to pass check it will supply 2 minutes error tone through the phone then disconnect the phone 4 2 Board indicator state Power light external power indicator Talking light The indicator will light when the talking or ring or cannot find simcard Signal light network signal indicator flashing with signal and extinguish without
5. GSM Gateway with 4 8 16 32 Ports USER MANUAL N O A A WO N Page of 9 Introducing the GSM Gateway with 4 8 16 or 32 incoming ports When connected to a PABX or various SLT phones the Gateway provides clear and reliable voice communication and is ideal for use in schools hospitals site offices etc particularly in areas where land lines are erratic or not available Please read the user manual carefully before installing the Gateway Contents Summarize eaacengocacaunecesaxaccesnerseaesacenceneserensteeedseaeiascouadsdecesesseedeudecns 2 Configurationand installation cece eee cc eeeee nese eee eneeeeeeeeeeeneaeeeeene 2 PUMCTHON missetoccesetoeseenressestatauronysatensanvenasnceatadessssauenssinesenseuecnessoesens 3 OPCION caneeseesesccsap sasecescesaeecasses cores seusee sacs E E E 3 TECNNOIOQY vie secon 5s cece natacehacccanatagsniceannce ns saumeseaenaaw mines eaamanawitetenccecstne 4 Led status COSCIIDG ooc05 1cc5cccacaccactanscnveasceneeceeeaensrewteseemnesienbeleeeesewacancded 6 Parameter SCUING amp occ0s55ccccaccacesaccanentansniccenttunewewiaeedseeneeeieesdeseetiatiensanckus 6 Page 2 of 9 1 Summarize The design of the 4 8 16 32 Gateway is to connect a standard telephone or PABX to the GSM Cell Network of your choice The interface board of the 4 8 16 32 Gateway supply a clear bond between standard phone or a VOIP GATEWAY or A PBX and GSM Cell Network it has the function of the emulation phone exchanger
6. arameter setting Setting the parameter by phone Entering the setting statuse 888999 Esc the setting statuse and saveing the data 00 0 Page 7 of 9 type ___ describe __ S s Setting _ SSC Set local code 10 code ras ee a Set IP1 0 11 1P 1H Set IP2 00 12 IP2 wel a Limit ou 2 9 201 21 0 B Megin x note X 1 4 Lock sim HIDE GGH 66 OH caller ID DIALING out s4 5 AFTER 67 X X IS DELAY TIME DELAY TIME 78 0 Le PGSM betas 900MHZ Gii a DCS 1800M _ 78 2 OO PCS ae y option EGSM as 900 1800M GSM ee s50 1900M_ D 88 1 FSK Mode I I SEX if you want a caller is CALLER ID option with a correct date need to set the date and time 88 O DTMF mode Fist MM is month DD is day HH is hours Second mm is minutes DATE AND TIME option 44 MMDDHHmm Acquiescence Special number 6000 IP1 no Call limit close Internal long distance call limit Page 8 of 9 close Local phone number call limit close Earphone volume rate 3 1 4 MIC Volume rate 3 1 4 Lock card state close Local code no Phone IP close International call limit close local call close PIN Earphone volume 3 1 4 MIC Volume adjust 3 1 4 Lock unit state close
7. tact to the supplier if there is something wrong with the unit Do not open the equipment box or repaired by unauthorized company or persons Avoid abnormal damage e Antenna Use the antenna which is via approbation Do not connect to the unnecessary antenna The unqualified antenna will damage the unit Lay the antenna vertically and be far from the phone do not bind the antenna cable and the phone line Do not touch the antenna or close to the antenna less 10cm when you are on communication e Power Supply Use the power supply which is via approbation Do not connect to the unnecessary one The unqualified power supply will damage the unit Operation temperature go up is the normal phenomenon e Installation and Conjunction Install the unit according to the manual and close the power when you connects the unit to other unit because during operation the power is on and it will damage the unit e Set Carry out operation and communication after being initialized setting by the supplier or the network operator Only the supplier and the network operator have right to set the system setting e Connect to other equipment Please read the manual carefully to gain safe guide before connecting to other equipment Do not connect to unnecessary products 6 Led status describe PWR red power indication Talking Yellow talking ring no sim card insert SlG green signal indication In use green pick off indication no gsm module 7 P