Instruction Manual v1_0
Contents
1. Status Description Last Test u E Peng Recycled Operating Table 29 10 2009 Client o DeMira 2 NI J A KUNDE B 8 El H Hospital A Asset Details n Asset Details Test Results Applied Parts Test Sequence Test Results Date Tested Overall Status Details 10 09 2009 8 Delete 29 10 2009 an Browse Search Reset a UMEN M Each complete Test Result set is shown as a single line Use the Details button to display the detailed results for the selected test The grey symbol 2 indicates that there are no test results saved Rigel Medical Med eBase Version 2 0 Instruction Manual Revision 1 0 21 For a detailed report click on the result and select the Details button This opens a new window which shows the detailed test information A green flag indicates that these tests have passed A blue icon indicates that the result is information only and there is no Pass or Fail status Test Results Cryeral Result Details Test Date 29 10 2009 18 20 00 Tested By PZ H Test Instrument Hin Test Mode Semi aubomatic Tester Serial No 205 0566 Test Results Live PE voltage Result B Neutral PE Voltage Recut Load Current Result B Load kVA Result Appled Part Leakage Drect 62353 Result Comments eC CB Rigel
2. 9 1 5 Connecting to a Database 10 16 12 1 7 Deleting Clients Sites Locations or Assets 13 IP EE opi a cm 13 1 9 Download from 14 1 10 Creating a new 16 1 11 UI PIOAGING edad 17 2 ASSET DETAIL VIEW 18 21 Comparison Aleris ico teste vasca ia 19 2 2 Viewing Test Results u c Rt ete i ci 21 2 3 PINGING ASSGLS aqnis 24 3 PRINTING CERTIFICATES 28 4 LANGUAGE SETTINGS 30 5 5 sues uides ed 31 5 1 Compatibility with Additional Testers 31 6 TROUBLESHOOTING 32 7 SPECIFICATION S iiiter lt lt aero 33 7 1 Program Specification 33 7 2 System 0 22 33 8 WARRANTY AND SUPPORT 34 Rigel Medical Med eBase Version 2 0 Instruction Manual Revision 1 0 4 Introduction Higel Med eBase Version 2 0 is our latest software application dedicated to medical safet
3. Enen a 1 Connect to Database sQute Database M5 80 ODBC MySQL Database I SQLite databases are saved as Files and do not require a database server Create a new SQLite Database Open an existing SQLite Database Rigel Medical Med eBase Version 2 0 Instruction Manual Revision 1 0 8 1 4 Import Med eBase Version 1 Database SQL Express which is included with a Med eBase V1 0 installation is required on the local computer to allow importing of a Med eBase V1 0 database From the File drop down menu select Import Med eBase V1 Database Rigel Med eBase D Documents and Edi Tools Help amp Connect to Database amp Import Med eBase v1 Database Export Database a Di i a 1 A dialogue box will appear see below after clicking on the Browse button select the location where the Med eBase V1 database has been saved click OK and the Med eBase V1 data will appear in the new Med eBase V2 0 database Import Legacy Database Med eBase V1 Browse Import Assets Results Test Sequences x Rigel Medical Med eBase Version 2 0 Instruction Manual Revision 1 0 9 1 5 Connecting to a Database From the File drop down select Connect to Database Rigel Med eBase D Documents and mim Edi Tools Help t Connect to Datab
4. m 002 11 06 2010 003 11 05 2010 After selecting to create test certificates the following window appears E Generate Certificate Template Print Preview default Header Electrical Safety Certificate Electrical Safety Certificate Test Company Name Acme Test Limited Address Line 1 12 Tester Lane Address Line 2 Tester Town Address Line 3 Testershire Post Cade Client Details Mame Medicorp Limited Address Line 1 34 Medicine Road Address Line 2 Medical City Address Line 3 Post Code Date Formats Test Date dd Rie best Date dd MMMM Today s Date dd Tester s Signature Rigel Medical Med eBase Version 2 0 Instruction Manual Revision 1 0 28 Template Print Preview defaulE lt Header Electrical Safety Certificate Test Company Mame Acme Test Limited Address Line 1 12 Tester Lane Address Line 2 Tester Town Address Line 3 Testershire Post Code T51 15T Browse Logo sfimagesflogo png Client Details Mame Medicorp Limited Address Line 1 34 Medicine Road Address Line 2 Medical City Enim Address Line 3 Post Code Moi 1DM Dake Formats Test Date dd MMMM Re test Date dd MMMM Today s Date dd MMMM Tester s Signature Brawse Once the test certificate window
5. MEDICAL MED BASE Software Version 2 0 Rigel Asset Management Software Instruction Manual 383A550 Rev 1 0 September 2010 2010 Seaward Group Issue 1 0 Disclaimer Limited Warranty amp Limitation of Liability Rigel Medical part of the SEAWARD GROUP guarantees this software package for a period of 1 year The period of warranty will be effective at the day of delivery Although all Seaward Group software programs are tested before release no claim is made concerning the accuracy of the software or its associated documentation The oeaward Group and Distributors of this software cannot assume liability or responsibility for any loss or damage arising from the use of this program Copyright 2010 All rights reserved No part of this publication or software may be reproduced or transmitted in any form or by any means electronic or mechanical including photocopying recording or any information storage and retrieval system without the permission in writing from SEAWARD GROUP Due to a policy of continuous development the SEAWARD GROUP reserves the right to alter the equipment specification and description outlined in this publication without prior notice and no part of this publication shall be deemed to be part of any contract for the equipment unless specifically referred to as an inclusion within such contract License Agreement This is a legal agreement between you either an individual or an orga
6. 600 Port Bluetooth Communications Pork COPS Re scan Ports The program will then wait for the data to be sent see Rigel tester Instruction Manual for setting the tester into Upload mode Rigel Medical Med eBase Version 2 0 Instruction Manual Revision 1 0 17 2 Asset Detail View The Asset Details can be obtained by clicking on the Asset in the Asset Table View The following information will appear in the Asset Details panel Asset Details E i Asset Details Test Results Applied Parts Test Sequence Details Asset Name 1234 Manufacturer KETN v Description Operating Table Model UNBEKANNT Client ae Serial Mo 123456 v Site Name Hospital A Service Code bel Location Mame Operating Theatre Equipment Class he Test Period AP Configuration Re test Period tmonths 0 s Next Test 2BF Via the following tabs Asset Details Test Results Applied Part Configuratio Test Sequence Asset trace Variables are described in a later chapter The test period is downloaded from the Rigel tester however it can be altered manually by altering the re test period on the Asset Details tab The Applied Part tab provides the settings of the patient connections and applied parts Each new Applied Part has a colour code so it can be distinguished from other Applied Parts in the Connections diagram Asset Details Asset Details Test Results Applied
7. m 25 MM 2 98 29 0231 1 3M i 2 4 5 gt M IE NEC Select ane or mare criteria to search by Another search function is to filter failed passed or uploaded tests 1 YL Re Eesk Date From To Overall Status Enter the required search parameters and select Search to begin the search The results will be displayed in the Asset table View Poe Poeounreis and Se tines Janes ion Med chuse Y iDatabasess Jar eating ob Hep Denr pio deng eo code Date Toc AP Conf os Rigel Medical Med eBase Version 2 0 Instruction Manual Revision 1 0 26 From this window the user is able to Upload or Generate Certificates for the selection of Assets Assets can also be sorted on the different Asset variables by entering additional search criteria into the schedule window Rigel Medical Med eBase Version 2 0 Instruction Manual Revision 1 0 27 3 Printing Certificates Med eBase contains an automatic certificate generator which will produce either a paper copy Print HTML or PDF version for easy electronic transfer between different parties Select the relevant Assets s then select Create Certificate from the context menu Alternatively all Asset context menu items can be found the right of the table view Status Description Last Test 001 11 08 2010
8. Medical Med eBase Version 2 0 Instruction Manual Revision 1 0 22 When clicking on the on the plus icon for one of the test results will open the item to show more details Test Results Overall Result Details Test Date 29 10 2009 18 20 00 Tested By PZ E Test Instrument Type 0 ow Test Mode Semi automatic Tester Serial No 205 0566 Test Resuks Enter details af test 6 Neutral PE Voltage Resul Ej H Load Current Result Load kvA Result 6 Live PE Voltage Result Equipment Leakage direct Resuk El Status Polarity Limit Resul fa Ru Normal 100 0000 z4 00600 ACIDC combined Rewverzed 00 0000 4 0000 ACTI C combined Appled Part Leakage Direct 62353 Result Comments accaun The Test Instrument Serial Number Test Mode and Tested By fields are derived from the downloaded data and automatically filled out The Test Result details will vary for different Test Types possible values are Mains SFC AP Type Limit Result Unit and Status Rigel Medical Med eBase Version 2 0 Instruction Manual Revision 1 0 23 2 3 Finding Assets To quickly find an Asset within the database the program contains a search facility that can be accessed via the Search option from the Edit menu Alternatively from the tool bar select the Search icon File Edit Tools Help gt cb IS 4 Browse assets Bi Asset Mame Description Client Site Location Ma
9. sites under the client selected in the Client field To save the entries click Apply button or discard the entered details by clicking the Reset button Asset Name and Serial Number combination must be unique across the database If an Asset Name and Serial Number combination is entered which already exists Med eBase will display an error Retest period is configured in months and the Next test date will be automatically calculated based on the selection Rigel Medical Med eBase Version 2 0 Instruction Manual Revision 1 0 16 1 11 Uploading Some Rigel testers have facilities for Uploading Assets and the last test routine back into the Rigel tester memory for re test see application note nr 13 on www rigelmedical com to activate the sss format on the older Rigel testers To upload Assets to the tester select the relevant Asset s then right click and select Upload Rigel Med eBase D Documents and Settings JanR Desktop Med eBase V 2 Databas File Edit Tools Help EG B 5 E ES tik 4 Browse Assets Testing db Recycled Sa Client S fo Mamet 2 KUNDE eerste Certificates B KKK w 1 Hospital A Btatus Bul Add New Asset Delete Assets i i From the Upload Assets to Tester dialog box select the relevant Baud Rate and COM Port from the drop downs and then select OK to commence the Upload action Upload Assets to lester Baud Rate
10. Parts Test Sequence Connections Mame Type af connections B e 111 TwpeB 2 2 7 ele BF 4 E 3 3 CF 4 ao E 19 Rigel Medical Med eBase Version 2 0 Instruction Manual Revision 1 0 18 2 1 Comparison Alerts Under the Tools menu there is an option to open the Comparison Alerts screen This will allow users to compare new results with previously measured results f Rigel Med eBase D Documents and Set File Edit EE Help i 1 k R ES Change Language Browse Assel amp Create Certificates kd Alei E Comparison Alerts 3 9 Global Test Sequences a 40 Download amp Ti Upload Activate Additional Features 9 8 8 In the new dialog enter a number or percentage to search and the program will find results that vary accordingly zi Comparison Alerts Alert on resistance results that vary by more than ts ORs Alert an insulation results that vary by more 2 OR 10 Me Alert on leakage results that vary by more than 20 OR Remove Alerts Find Alerts If any results change by an amount specified in the comparison alerts dialogue then an alert symbol will appear next to the test result Click Find Alerts to list all results sets that contain at least one result alert i MedeBase The search Found 5 alertis Would you like to view these assets now Rigel Medical Med eBase Version 2 0 I
11. W England www rigelmedical com e mail support rigelmedical com Telephone Support Helpline 44 0 191 5878730 Fax 44 0 191 5860227 Rigel Medical Med eBase Version 2 0 Instruction Manual Revision 1 0 34
12. although a number of databases can be created and selected from The Med eBase database is structured around the owner Client and physical location Site amp Location of Assets items requiring testing Browse Assets e ERES Recycled Client Hospital W service a SL fo namat a 5 KUNDE E 28 kkk 5 Hospital A Oper atin A Site may contain a number of locations such as individual wards or departments By selecting a Site or Location from within the Browse Assets tree the Asset Table View will display all the Assets within the selected Site or Location The Client name sites and locations come directly from the Rigel testers upon download and can be edited by clicking again on a highlighted name Rigel Medical Med eBase Version 2 0 Instruction Manual Revision 1 0 12 1 7 Deleting Clients Sites Locations or Assets Clients Sites Location and Assets may be deleted by right mouse clicking the relevant item and selecting Delete Client Delete Site Delete Location or Delete Assets There is no limit to how long the Client tree is or how many Assets it contains All deleted Assets are placed in the Recycled folder on the Browse Assets tree and can be displayed by selecting the folder These Assets and its tree structure if necessary can be restored by right mouse clicking on the relevant Asset s within the Recycled folder and selecting Restore Assets Similarly they can be permanently deleted by
13. ase 6 Import Med eBase v1 Database Export Database Di oua The will open a window to connect to a database Connect to Database SQLite databases are saved as files and do not require a databaseeer yer C3 New Create a new SQLite Database EE Open Open an existing SQLite Database Create New SQLite Database Connect to an existing SQLite Database 10 Rigel Medical Med eBase Version 2 0 Instruction Manual Revision 1 0 To connect to a Microsoft SQL Server over ODBC click on the MS SQL ODBC tab The connection details should be provided by the network administrator and will be retained for future use Connect to Database SQLite Database Connect to a Microsoft SOL Server over ODBC Server Database Marne Populate Use Windows MT Integrated Security User Warne Password Create New Database To connect to a MySQL Database select the MySQL Database tab The connection details should be provided by the network administrator and will be retained for future use Connect to Database SQLite Database SQL ODBC MySQL Database Connect natively to a MySQL server Hast Mame Database Mame Populate User Mame Password Create New Database Rigel Medical Med eBase Version 2 0 Instruction Manual Revision 1 0 11 1 6 Data Structure Med eBase can only display one database at any one time
14. cted in the tester oelect the appropriate serial port from the COM Port drop down The Re Scan COM Ports button gives you the option to refresh the communications ports available prior to download With the tester connected to the appropriate COM Port select OK on Med eBase to commence the download Then initiate the download on the tester See the appropriate tester Instruction Manual on how to commence a download action otart the download on the Rigel tester Downloading data Estimated time remaining Unknown Estimated Finish time Unknown 0 Rigel Medical Med eBase Version 2 0 Instruction Manual Revision 1 0 14 Once the download is underway a progress bar will appear Please note that with older firmware versions the time will be unknown Downloading Assets Received packet id 127 Estimated time remaining Unknown Estimated Finish time Unknown Downloading Assets Received packet id 16 Estimated time remaining Unknown Estimated Finish time Unknown Upon completion of the download the window will close and display the download report Download Report 6 assets downloaded with status Pass assets downloaded with status Fail 0 assets downloaded with test results assets downloaded with no new test results assets downloaded with status Alert 0 global test sequences downloaded Rigel Medical Med eBase Version 2 0 Instruction Manual Revision 1 0 15 1 10 Crea
15. he installation Follow the on screen instructions Once the program is installed a shortcut will be provided on the desktop Double click the shortcut to open the program A start up screen will appear until the full program is loaded The first time Med eBase 2 0 is run it will require a Language selection The language can also be changed later as required from within the program Rigel Medical Med eBase Version 2 0 Instruction Manual Revision 1 0 6 1 2 Navigating Med eBase Med eBase main screen is divided into three main sections Rigel Med eBase C Program Files Rigel Med eBase V2 Databases example db BE File Edit Tools Help E Browse Assets 3 Status Mame Description Last Test Retest Date Recycled zl Client 4 E Hospital R Operating The e l Hospital B8 Client B HL Hospital 4 2 E example db 1 12 Operating Table 11 08 2010 l Asset Details Asset Details Test Results Applied Parts Test Sequence Details 3 Asset Name 12 Serial 0017 Description Operating Table Manufacturer MEDTRONIC Client Client 4 Model S DjSGJOSOOOUiIEi E Site Mame Hospital 4 Service Code Location Mame Operating Theatre Equipment Class 3 Test Period AP Configuratio
16. is opened test certificates can be customised to contain any Test Company and Client Details The Test Date and Re Test Date can be formatted to suit and it is also possible to add a personal Logo and an electronic signature image Page Setup Choose Print for output to your windows default printer Choose Save to save an electronic copy of the certificate s in either HTML or PDF format Rigel Medical Med eBase Version 2 0 Instruction Manual Revision 1 0 29 4 Language Settings The Med eBase program can be used in a number of different languages Due to the continuous development additional languages are scheduled to be made available For availability of other languages please contact Rigel Medical via email info rigelmedical com To change the language select Tools then Change Language and select the required language Rigel Med eBase D Documents and Settings Brom File Edit Tools Help ta CES Language gt ch German Mc eS English Browse Assel te Lertiricare Spanish Alei Comparison Alerts French E Global Test Sequences Italiar E E Polish 5 40 Download a 22 Upload Activate Additional Features Rigel Medical Med eBase Version 2 0 Instruction Manual Revision 1 0 30 9 License To activate additional Med eBase features select Tools from the drop down menu and
17. n Next Test 0212011 view Browse Search Reset Explanation of the main screen 1 The Browse Assets view With the Browse tab selected the tree view shows the Assets of the database organized by Client Site and Location The Search tab provides a form to find Assets based on criteria such as name description serial number and dates 2 The Asset Table View displays the Assets for a particular item selected in the Asset tree view 3 The Asset Details View Displays Asset details including test results Applied Parts and Test Sequences Rigel Medical Med eBase Version 2 0 Instruction Manual Revision 1 0 7 1 3 Creating a new Database From the File drop down select Connect to Database select the Database format required Provided with the install is SQLite Database format To use this select New Browse to the location you want the database enter the name of the new database into the File name field and then click Save to complete the action The program allows choice between a e local Database which is fast has no server a single user access and no concurrency issues e Remote Database which has all the data stored at a centralised location is accessed by many people concurrently and can be used with other database tools Rigel Med eBase D Documents and x39 Edit Tools Help oe Connect to Database a Import Med eBase V1 Database m Export Database
18. nisation and Seaward Electronic Ltd By installing this software you are agreeing to be bound by the terms of this Agreement If you do not agree to the terms of this Agreement do not install the software and promptly return the software and the accompanying items including written materials and binders or other containers if any to the place you obtained them for a full refund SOFTWARE LICENCE 1 GRANT OF LICENCE Seaward Electronic Ltd grants to you the right to use one copy of the enclosed Seaward Electronic Ltd software program the Software on a single computer The Software is in use on a computer includes when it is loaded into temporary memory i e or installed into permanent memory e g hard disk or any other device 2 COPYRIGHT The Software is owned by Seaward Electronic Ltd and is protected by copyright laws Therefore you must treat the Software like any other copyright material e g a book or musical recording You may not copy the written materials accompanying the Software 3 OTHER RESTRICTIONS You may not rent or lease the Software You may not reverse engineer decompile or disassemble the Software than otherwise provided for by law USE ON ONE COMPUTER ONLY This license allows the Software to be installed into the permanent memory hard disk of only one computer at a time LIMITED WARRANTY Seaward Electronic warrants that a the Software will perform substantially in accordance with the accompan
19. nstruction Manual Revision 1 0 19 After clicking on Yes the following screen appears displaying the Alerts founds Rigel Med eBase D Documents and 5ettings JanR Desktop Med eBase V7 Databases Jan Testing db File i Edit Tools Help amp EB B E E EQ 4 Browse Assets m E Status Mame Description Last Test Asset Mame 1 E 851004183 16 04 2009 Description 2 E 903559 30 04 2009 Client ien 3 F FAM ACCa 00 21 10 2009 Site 4 2584 04 11 2009 Location To Remove the Alerts found click on the Remove Alerts button Comparison Alerts da Alert an resistance results that vary by more than 15 OR 0 05 Alert an insulation results that vary by bre than 2n SM OR 10 Me Alert on leakage results vary by more than z 10 uA Remove Alerts Find Alerts The icon below confirms that the Remove Alerts has been carried out Ed MedeBase i All assets results with Alert status have now been reset to Pass status Rigel Medical Med eBase Version 2 0 Instruction Manual Revision 1 0 20 2 2 Viewing Test Results From the Asset Details panel select the Test Results tab This will display the Test Result history for that Asset Rigel Med eBase D Documents and Settings JanR Desktop Med eBase 2 Sime File Edit Tools E BR t L EB m AmE Browse Assets B p
20. nufacturer Model Serial Ma Service Code Re Eesk Date From Ta y Overall Status There is also Search button in the bottom of the left corner next to the Browse button Search Browse Search Enter the relevant search criteria then select Search to commence the search Results will be shown in the Asset Table View panel Please note the character can be used as a wildcard character in the search fields Ward12 in the Location field will find all Assets with a Location starting with Ward12 e g Ward12 Ward12A Ward12B etc Rigel Medical Med eBase Version 2 0 Instruction Manual Revision 1 0 24 Ripe Mes ease Ddidacuments and Settinps Jank DesktooMed ebase VY Zilatabases Jan leanne db After selecting an Asset the associated Asset Details Test Results Applied Parts Test Sequences are shown in the Asset Details below Dodidacuments and Settinps Jank DesktooMed ebase Wwe Lame a Rigel Medical Med eBase Version 2 0 Instruction Manual Revision 1 0 25 A useful search is the next re test date Service Code Re Eesk Date From Ta Overall Status Bee ZUS SO OI ce 8 L3 Aca 6 cg Be 3 zu H 175 dS d6 SGT EM 10 ZE 22 W
21. se of any problems occurring find the error log in the Med eBase V2 install directory The error log file is called debug output txt Attach this to an email and send it to Rigel Medical for investigation Please include a brief explanation of what caused the problem to enable us to resolve the matter as efficiently as possible support rigelmedical com Rigel Medical Med eBase Version 2 0 Instruction Manual Revision 1 0 32 7 Specifications 7 1 Program Specification The program group consists of Data Transfer Utility User Manual Higel Med eBase Uninstall program can Upload to and receive Download data from the following test instruments e Rigel 288 62353 e Rigel SP SiM UNI SiIM Providing they have been enabled within Med eBase V2 7 2 System Requirements IBM Compatible PC Processor Speed 1Ghz or higher Microsoft Windows XP SP2 Vista Windows 7 32 bit 64 bit Operating Systems 512Mb RAM 350Mb available hard disk space Colour monitor with 32 bit colour or greater video card CD ROM drive Rigel Medical Med eBase Version 2 0 Instruction Manual Revision 1 0 33 8 Warranty and Support Rigel Medical part of the SEAWARD GROUP provides warranty for this software package for a period of 1 year This will be effective from the date of delivery For this and further information contact Rigel Medical Bracken Hill South West Industrial Estate Peterlee Co Durham SR8 2S
22. select Activate Additional Features File t Rigel Med eBase D Documents and Set Edit Help Change Language d Browse Assel 2 Comparison Alerts 9 Global Test Sequences 2 40 Download H BS Ge Upload Activate Additional Features 5 1 Compatibility with Additional Testers A standard Med eBase License allows compatibility with Rigel 288 and Rigel 62353 testers To use Med eBase with additional testers e g the SIM range then you must Activate Additional Features Selecting this option will open the Activation window Activation keys are purchased from Rigel Please contact sales rigelmedical com for further details Activate Med eBase Serial Number Your serial number can be Found inside the Med ebase DYD case IF you do not have a serial number and vau would like to purchase ene please contact Rigel 44 00191 587 8730 __ HH FL H A Main Activation Kev Please contact Rigel Medical by phone 44 03191 587 8730 or by email at supporki rigelmedical cam with vour serial number to receive an activation Si Range Activation Kev Please Fill in the Following key to unlock communication with the Rigel range of testers This key will be sent bo you along with Ehe main activation key if it has been purchased A Rigel Medical Med eBase Version 2 0 Instruction Manual Revision 1 0 31 6 Troubleshooting In the ca
23. selecting Delete Assets from this menu By holding Ctrl on the keyboard multiple assets can be selected and manipulated simultaneously in the Asset Table View 1 8 Context Menus All Icons have a right mouse button action The following actions can be initiated from the right mouse button The Asset context menu from any Asset in the Asset Table View has the following options 3 Add Mew Asset Delete Assets Upload Create Certificates The Asset context menu from an Asset in the Recycled folder has the following alternative options e Restore Assets S Delete Assets 00 Context menu from Clients Sites and Locations in the Browse Assets tree view only has a relevant Delete option Rigel Medical Med eBase Version 2 0 Instruction Manual Revision 1 0 13 1 9 Download from a tester For more detail on connecting with a test instrument or connecting when using Windows 7 or Vista operating systems refer to the instruction manual provided With the test instrument Download can be initiated from the Download option in the Tools menu or from the Download icon in the task bar File Edit Tools Help fe E E BR TIO The Download dialog box will be displayed T Download from Tester Baud Rate ea M Port Bluetooth Communications Pork COPS Re scan COM Ports OK Select the relevant Baud Rate this MUST match the option sele
24. ting a new Asset New assets can be created by clicking the Add Assets button in the main screen This will enable an empty Asset Details panel pre populated with the tree structure values as necessary Rigel Med eBase D Documents and Settings JanKk Desktop Med eBase V7 Databas PIE File Edit Tools Help ES 84 tb t mi 4e Browse Assets m TE af i i Status Name Description Last Test eO E Testing Recycled 1 Mizzi 12 03 2009 e enta E BS na inm d oe MS DUE 3 M1327 12 03 2009 8 93 B Asset Details Asset Details Test Results Applied Parts Test Sequence BEEN Details Name M1322 Manufacturer Description mE Model Client Client wv Serial Mo v Site Mame Hospital 4 Service Code i Location Mame SERVICE Equipment Class kall Test Period AP Configuration Re test Period months 8 Test The maximum length of each field is 25 characters Asset Name is a mandatory field Each field s dropdown list holds the existing entries under its level For example site name contains all the
25. u acknowledge that you have read this Agreement and understand and agree to be bound by its terms and conditions without exception deletion or alteration You also agree that this Agreement sets out in full the Agreement between you and Seaward Electronic Ltd which supersede any proposal or prior Agreement oral or written and any other communication between you and Seaward Electronic relating to the subject matter of this Agreement INDEMNITY You agree to indemnify Seaward Electronic Ltd against any loss damage or expense arising out of or in connection with any unauthorized use reproduction sale making available by you of the Software including any loss damage or expense arising out of the subsequent use of the Software by any other person GOVERNING LAW This Agreement is governed by the laws of England and Wales Rigel Medical Med eBase Version 2 0 Instruction Manual Revision 1 0 3 Index DISCLAIMER LIMITED WARRANTY amp LIMITATION OF LIABILITY 2 LICENSE AGREEMENT e ree 3 INTRODUC HON eo spaces eo obe aenea 5 AOGELIHNGSOTARHEPED 52 909 9 90 50052002 2 32 6 1 1 Installing 6 1 2 Navigating 7 1 3 Creating a new 8 1 4 Import Med eBase Version 1 Database
26. y and functional testing This software incorporates a number of special features not previously associated with the recording and management of electrical and functional safety testing data This new program facilitates the production of a comprehensive series of advanced results and data reports including comparison alert function A unique option to store your data on a local or remote database structure and an exceptional layout makes the system easy to use with very little training required The Med eBase Software Version 2 0 can use both local and remote databases A local database requires no database server to be installed while a remote database allows multiple users to access the same data simultaneously The program will run on all Windows XP Vista or Windows 7 operating systems in both 32 Bit and 64 bit versions The new Med eBase software is delivered in a DVD case and with a license agreement and serial number for activation Rigel Medical Med eBase Version 2 0 Instruction Manual Revision 1 0 5 1 Getting Started 1 1 Installing Med eBase Note Before installing Med eBase ensure no other applications are running Installing Med eBase is easy Simply insert the CD into your CD drive the installation should start automatically If the CD does not automatically start up then use Windows Explorer or another file management application Select your CD drive double click with the mouse on the setup exe file to start t
27. ying written materials for a period of one year from the date of receipt and b any hardware accompanying the Software will be free from defects in materials and workmanship under normal use and service for a period of one 1 year from the date of receipt Any implied warranties on the Software and hardware are limited to one 1 year and one 1 year respectively CUSTOMER REMEDIES Seaward Electronics entire liability and your exclusive remedy shall be at Seaward Electronic option repair or replacement of the Software or hardware that does not meet Seaward Electronic Limited Warranty and which is returned to Seaward Electronic with a copy of your receipt This Limited Warranty is void if failure of the Software or hardware has resulted from accident abuse or misapplication Any replacement Software or hardware will be warranted for the remainder of the original warranty period NO LIABILITY FOR CONSEQUENTIAL DAMAGES In no event shall Seaward Electronic Ltd be liable for any damages whatsoever including without limitation damages for loss of business profits business interruption loss of business information or any other pecuniary loss arising out of the use of or inability to use this Seaward Electronic product even if Seaward Electronic has been advised of the possibility of such damages REGISTRATION Within seven days of installing the software you are required to register the software with Seaward Electronic Ltd By registering yo