Home
MartechnicLtd_BNWAS_U
Contents
1. e A NA 5 i Mas ia ie ar ag m 2 2s 1 955 it as a7 Poo 2 6 66 6 6 6 6 6 6 6 6 06 ale IIE3I33I332 to be mounted on terminal rail TS35 system voltage 18 0 31 2VDC power consumption 20W core size max 0 2 1 5mm power supply 0 2 2 5mm degree of enclosure IP 20 max depth 70mm weight 0 35kg safety distance to magnetic compass 0 5m U WAS 2000 User Manual R01 06 22 39 part no PCB08002 1 INDEX FELD NDERUNG AND MITT DATUM NAME 2008 TAG NAME BEARB 28 9 Streit IGEPR NORM connecting module INI AS LCM LO 24 Q ME AUFTRAG NR TYP AISTAND E ART BLATT 2 VON 2 Martechnic Ltd 30 210 4227267 wall cut out d 68mm for flush mounting only FIXING HOLES 4X 6 3 H1 H2 wallbox surface RAL 7035 nominal values 24VDC 350mA sound pressure level 64 111 db A adjustable sound characteristic 2850 Hz continuous cable diameter 8 0 16 0mm core size max 2 5mm degree of enclosure IP 65 depth without lower wall box part 30mm bulbs max 2x5W weight 0 870kg U WAS 2000 User Manual R01 06 23 39 25 1 5 upper wall
2. Do not accept offered buzzer characteristics during buzzer is activated Wait for the brake U WAS 2000 User Manual R01 06 17 39 Martechnic Ltd 30 210 4227267 Adjust internal buzzer s volume To adjust internal buzzer s volume turn key switch S1 on operating device LOD 210 24 0 0 to position SELECT Minimum sound volume is limted to 65dB A AUTO k it h WATCH ALARM N 2x16 character illuminated display U WAS 2000 UMAR SHIPPING SERVICES operating device rotary encoder incl LOD 210 24 0 0 push button S2 After turning key switch S1 to position SELECT display is showing text 3 display text 3 SET MAIN PERIOD 3 12min 3 Now push rotary encoder s push button S2 on operating device LOD 210 24 0 0 so often as display is showing text 23 display text 23 BUZZERs SOUND VOLUME 15 Now turn rotary encoder in counter clock wise direction to decrease buzzer s sound volume or in clock wise direction to increase sound volume By pushing rotary encoder s push button S2 display is changing and system accepts adjusted value Notice During alarm stage 1 alarm on bridge amp bridge wing area internal buzzer s sound volume can be adjusted by turning rotary encoder on operating device U WAS 2000 User Manual R01 06 18 39 Martechnic Ltd 30 210 4227267 9 technical data and schematics General description power supply power consumption internal fuses degree of enclosure weight approbation tra
3. RAL 7001 depht 90mm nominal values 24VDC 50mA cable diameter 9 5 20 0mm core size max 2 5mm degree of enclosure IP 65 weight 0 850kg NAME SE WALL BOX FOR RESET WATCH ALARM 18 aa f gt 220 gt 1 E UMAR j NR ART SHIPPING SERVICES triple link added BLATT VON U WAS 2000 User Manual R01 06 27 39 Martechnic Ltd 30 210 4227267 WATCH ALARM M32x1 5 NAME Streit 18 SHIPPING SERVICES U WAS 2000 User Manual R01 06 28 39 BLATT Martechnic Ltd 30 210 4227267 15 UMAR SHIPPING SERVICES EGREE O NNECTIN IRE TYPE VEICHT U WAS 2000 User Manual R01 06 29 39 Martechnic Ltd 30 210 4227267 WATCH ALARM M32x1 5 NAME Streit WALL BOX WITH BUZZER FOR WATCH ALARM ART SHIPPING SERVICES BLATT U WAS 2000 User Manual R01 06 30 39 Martechnic Ltd 30 210 4227267 llbox surface able diamete 1 e PERSONNEL ALARM ON OFF SYSTEM ON GN gn M32x1 5 UMAR ART A SHIPPING SERVICES U WA
4. power supply failed or main power supply voltage is lower than 13 2V b program cycle interrupted risc controller has been stopped c link with 15 pole system cable Z1 between operating device and connecting module is interrupted a check supply voltage by comparing it with other systems fed from same distribution source b Switch off system s power supply for minimum 10 sec by opening fuse holder F1 or F2 on connecting module LCM 210 24 0 0 After switching on power supply program will start automatically after 2 sec in normal mode C check system cable between connecting module LCM 210 24 0 0 and operating device LOD 210 24 0 0 especially system plug on operating device s rear side Cable might be damaged U WAS 2000 User Manual R01 06 12 39 Martechnic Ltd 30 210 4227267 System fail state is indicated when system fail relay K1 is not triggered control LED D9 is off Notice In case that during watch operations system s power supply fails temporary e g black out situation watch operations restart automatically with old settings settings before power fail time period cannot reset emergency call cannot reset check all reset units if reset contact is closed permanently by switch s malfunction or accidental use No indication light is active reset units amp external power on devices Check if system is might be switched off by external system Use key switch S1 on operating device LOD 210 24 0 0
5. using rotary encoder U WAS 2000 User Manual R01 06 14 39 Martechnic Ltd 30 210 4227267 7 adjust time period of alarm stage 2 alarm in officer s area for authorized persons only IMO regulations allow MSC 75 24 Add 1 ANNEX 11 4 1 2 7 to increase standard setting of 90 sec of alarm stage 2 alarm in officer s area Compare with chapter 9 technical data and schematics see watch alarm time table Adjustment could be necessary due to large vessel Period can be adjusted to max 180sec default value is 90sec to allow sufficient time for back up officer and or Master to reach bridge area before watch alarm system is triggering alarm stage 3 Write down decided new value here new time period of alarm stage 2 90sec 180sec date amp sign To adjust a m time period turn key switch S1 on operating device LOD 210 24 0 0 to position SELECT WATCH ALARM key switch 2x16 character U WAS 2000 1 illuminated display UMAR SHIPPING SERVICES rotary encoder incl push button S2 operating device LOD 210 24 0 0 U WAS 2000 User Manual R01 06 15 39 Martechnic Ltd 30 210 4227267 After turning key switch S1 to position SELECT display is showing text 3 display text 3 SET MAIN PERIOD 3 12min 3 Now push rotary encoder s push button S2 on operating device LOD 210 24 0 0 so often as display is showing text 24 display text 24 PERIOD ADJUST AL STAGE 2 090s Now turn rotary encod
6. 0 0 24VDC power supply U WAS 2000 User Manual R01 06 38 39 key switch S1 rotary encoder incl push button S2 Z1 15 pole connector to operating device terminals for periphery equipment Martechnic Ltd 30 210 4227267 Bridge Navigational Watch Alarm System sample system reset unit bridge wings WAR 220 2 1 0 reset units PIR motion sensor WAR 220 1 0 0 WATCH ALARM WMS 220 2 0 0 U WAS 2000 bridge area controller failure 0 TM officer s 9 area WAP 220 4 0 0 WAP 220 2 0 0 for corridor P for cabins upto 112dB A 75 85dB A time table Zk Setting max 90 sec ALARM ALARM IT Upto 11208 STAGE 3 OFFICER S Q g OFFICERSAREA AREA p t s 5 10 15 20 25 30 9 120 50 180 20 ALARM ARM 17 75 8908 STAGE2 OFFICERS Xi OFFICERSAREA AREA tis INDICATION RESET BRIDGEAREA UNITS SELECTED PERIOD MAIN PERIOD 3 12 min U WAS 2000 User Manual R01 06 39 39 Martechnic Ltd 30 210 4227267
7. 28V 40mA 3 WAR 2201 00 connecting type welding 0 045 d 0 75mm part no 099076 6 WAR 220 1 0 1 watch alarm reset push button illuminated 0 080 IP65 0 2 2 5mm 1x bulb Ba9s 28V 45mA connecting type screws part no 099083 220 1 0 0 watch alarm wall box with buzzer 85 dB A 0 750 IP65 0 2 2 5mm 8 WAB 220 2 0 0 external Walch arn buzzer 89 0B A 0 030 IP65 0 2 2 5mm lone whole installation 22 5mm 9 WAR 220 2 0 0 watch alarm wall box for reset illuminated 0 750 IP65 02 2 Same bulb T5 5 28V 40 part no 099076 10 WAR 220 2 1 0 watch alarm wall box for reset illuminated with buzzer 85 dB A 0 850 IP65 0 2 2 5mm 1x bulb T5 5 28V 40 part no 099076 U WAS 2000 User Manual R01 06 19 39 Martechnic Ltd 30 210 4227267 sample system connecting diagrame 1 2 3 4 5 6 7 8 OPERATING DEVICE LOD 210 24 0 0 U WAS 2000 CONNECTING MODULE PCB08002 6 LCM 210 24 0 0 T 15 pole plug LOAD OF OUTPUT CONTACTS 30VDC 2A gt z ALARM ALARM ALARM a STAGE 1 STAGE2 STAGE 3 5 t oe 5 PRE WARNING WARNING 5 gt STAGE3 gu nz BR
8. Ltd 30 210 4227267 Alarm stage 1 is triggered to pay attention to monitored OOW Sound characteristics and sound volume are adjustable see user manual chapter 8 1 additional potential free dry n o contact is closed now for further use as well as for VDR link Additional buzzers or alarm devices can be connected directly on connecting module 3 2 3 Alarm stage 2 If dormant main period flash light period 15 sec and alarm stage 1 15 sec are over without OOW s reset system activates alarm stage 2 Display on operating device is showing in toggle mode display text 16 and text 17 display text 16 RESET EXPECTED 1 29 display text 17 erie A 2 1 additional potential free dry n o contact is closed now for further use as well as for VDR link Optic acoustical alarm devices in officer s area cabins or staircase can be connected directly to connecting module 3 2 4 Alarm stage 3 If dormant main period flash light period 15 sec alarm stage 1 15 sec and alarm stage 2 90 sec are over without OOW s reset system activates alarm stage 3 Display on operating device is showing in toggle mode display text 18 and text 19 display text 18 RESET EXPECTED ALARM STAGE 3 display text 19 ALARM STAGE 3 RELEASED U WAS 2000 User Manual R01 06 36 39 Martechnic Ltd 30 210 4227267 Two potential free dry n o contacts on connecting module are closed now for alarm stage 3 trigger very loud alarm device
9. Notice time period reset unit illumination and external power on indication are active only when count down sequence is started If system works properly but without any indication one bulb or LED in time period reset units or external power on devices might be blown in that way causing a short circuit Replace damaged bulb LED Short circuit does not damage system due to short circuit protected transistor outputs U WAS 2000 User Manual R01 06 13 39 Martechnic Ltd 30 210 4227267 6 centralized dimmer U WAS 2000 BNWAS is designed with a centralized dimmer function That means all relevant illuminated time period reset units on bridge and bridge wing area as well as blue display on operating device LOD 210 24 0 0 are adjustable by turning rotary encoder S2 on operating device LOD 210 24 0 0 Minimum illumination is limited Dispay s illumination and time period reset unit s illumination are sychronized key switch SI 2x16 character WATCH ALARM wer U WAS 2000 SELECT illuminated display UMAR SHIPPING SERVICES rotary encoder incl ti operating device push button S2 LOD 210 24 0 0 By turning rotary encoder S2 on operating device LOD 210 24 0 0 in counter clock wise direction illumination is decreasing By turning rotary encoder S2 on operating device LOD 210 24 0 0 in clockwise direction illumination is increasing Notice dimmer function is suppressed during any kind of settings changing procedure by
10. TEST MODE2 OFF OFFICERs ALARM Display is showing text 6 and after pushing rotary encoder s push button S2 for one time all alarm devices in officer s area alarm stage 2 and link to VDR system optional are activated as long as push button is pushed again During this manual alarm activation display is showing text 7 display text 7 TEST MODE2 ON OFFICERs ALARM After a m test in test mode 2 is done user has to turn rotary encoder clockwise to reach test mode 3 display text 8 TEST MODE3 OFF ALARM STAGE 3 Display is showing text 8 and after pushing rotary encoder s push button S2 for one time system s contact is activating very loud alarm devices in officer s area alarm stage 3 and link to VDR system optional as long as push button is pushed again During this manual alarm activation display is showing text 9 display text 9 TEST MODE3 ON ALARM STAGE 3 U WAS 2000 User Manual R01 06 9 39 Martechnic Ltd 30 210 4227267 After a m test in test mode 3 is done user has to turn rotary encoder clockwise to reach test mode 4 display text 10 TESTMODE4 OFF DEVICE FAILURE Display is showing text 10 and after pushing rotary encoder s push button S2 for one time device s failure contact opens and activate linked alarm system as long as push button S2 is pushed again Consider possible alarm delay period created by linked alarm system During
11. time period reset units are activated Illumination of display and of reset units is adjustable by turning rotary encoder Minimum illumination is fixed Now push external reset units one by one and check 2 line of display current value Every reset should restart count down 2 59 U WAS 2000 User Manual R01 06 6 39 Martechnic Ltd 30 210 4227267 Test of external power on devices optional In case external power on devices are involved activate these devices one by one Make sure before display text 1 is shown Only in this auto mode an external power is possible display text 1 READY FOR POWER ON AUTO notice Every switching on from operating device LOD 210 24 0 0 or from external devices restarts count down Test of external alarm devices and links For checking alarm devices external buzzers on bridge or bridge wing area alarm panels in officer s area link to general alarm system link to VDR system and system failure contact see chapter 4 test mode maintenance amp service For finishing commissioning procedure switch off system by turning key switch S1 on operating device LOD 210 24 0 0 to position ON OFF for longer than 2 sec Display shuts down and system ignores all external inputs now system is shut down U WAS 2000 User Manual R01 06 7 39 Martechnic Ltd 30 210 4227267 4 test mode maintenance amp service U WAS 2000 Bridge Navigational W
12. 0009000 system fail relay K1 with control LED 1 After switching on 24VDC power supply generally from 24VDC Emergency Distribution Board system fail relay K1 is activated and display on operating device LOD 210 24 0 0 shows text 1 after a short intro procedure In case of system fail relay K1 is not activated control LED D9 is switched off When system is running properly relay K1 is triggered and its potential free contact is closed X1 5 6 Make sure that up to now no external power on contact steady contact X1 29 30 and pulsed contact X1 26 27 amp 50 51 is active display text 1 READY FOR POWER ON AUTO U WAS 2000 User Manual R01 06 5 39 Martechnic Ltd 30 210 4227267 System is running now and is waiting for user s operation on operating device LOD 210 24 0 0 or for an external power on command Display shows text1 Switch on system by turning key switch S1 on operating device LOD 210 24 0 0 one time to position ON OFF After system is switched on default dormant period 3 00min is counting down and display shows current state of count down display text 3 WATCH ALARM key switch 2x16 character U WAS 2000 illuminated dispa UMAR SHIPPING SERVICES rotary encoder incl push button S2 operating device LOD 210 24 0 0 display text 2 COUNT DOWN 2 59 eee Test of external illuminated time period reset unit In this count down mode all illuminated
13. Bridge Navigational Watch Alarm System e U WAS 2000 umar User Manual SHIPPING SERVICES 37 Syngrou Avenue 117 43 Athens Greece T 30 2104227267 F 30 2104227275 sales martechnicltd com Bridge Navigational Watch Alarm System acc MSC 128 75 U WAS 2000 user manual AUTO WATCH ALARM operating device V WAS 2000 LOD 210 24 0 0 with display key switch amp rotary encoder w push button UMAR SHIPPING SERVICES 2202 1 setssesscccscosecossonos connecting module LCM 210 24 0 0 contents instruction for use installation commissioning test mode maintenance amp service trouble shooting centralized dimmer adjust time period of alarm stage 2 alarm in officer s area adjust buzzer characteristics amp volume technical data amp schematics user manual short version for users only U WAS 2000 User Manual R01 06 1 39 Martechnic Ltd 30 210 4227267 1 instruction for use U WAS 2000 and its extension devices time period reset units alarm devices must only be installed by trained electricians or other persons who are familiar with installation of electric equipment Parts of the system can be damaged and persons put at risk if system is connected incorrectly Connecting module LCM 210 24 0 0 is designed to be installed in an enclosure switch cabinet or control console For service and commissioning work connecting module should be installed
14. IDGE AREA OFFICER S AREA ds Qs ag TRIGGER ss 5 go ACOUSTICS CABINS or STAIRCASE sg amp 2 gt 5 za zs ES w 58 ov av ov voy a D E ia E r3 ET fr um P 23 ov T 3 4 5 16 29 30 ii 10 34 ul 135136 38 4 4 05 6 47 49 26 27 28 52 f f 3 5 1 2 12 12 12 12 i i qn LU 1 D 5 amp 8 a a 8 8 No N WAB 220 2 0 0 Ko Ne optional 1 1 4 2 2 rites o o o o o o ita WAR 220 1 0 0 WAR 220100 WAR 220 100 WAR 220 100 WAR 220100 WAR 220 1 0 0 WAR 220 2 1 0 WAR 220 2 1 0 SYSTEM ON SYSTEM ON 5 Lil WAR 220 2 0 0 WAR 220 2 0 0 WAR 220 2 0 0 WAR 220 2 0 0 WAR 220 2 0 0 WAR 220 2 0 0 ER ENTRANCE ER ENTRANCE 2 3 J No WAP220 2 0 0 optional ALARM amp RESET U N ITS used only for Engine Room watch 5 5 5 3 149 by using more than 10 indications use LEDs 8 8 8 8 BRIDGE AREA Scc c c Saf 245 I WAP220200 220400 ALARM DEVICES ALARM DEVICES OFFICER S AREA OFFICER S AREA STAGE 2 ALARM STAGE 3 ALARM 75 85dB A 1m 85 112dB A 1m C X1 11 12 changed into power output 31 8 09 T Streit date 23 10 2008 Scale Title HULL E GA tigger changed into REVUE 30 5 08 L E ne T Streit Shipyard Aa BRIDGE NAVIGATIONAL i 1 terminal no changed 2 Streit contr class rawing No sh modificatio
15. S 2000 User Manual R01 06 31 39 BLATT VON Martechnic Ltd 30 210 4227267 10 user manual short version for users only U WAS 2000 Watch Alarm System acc MSC 128 75 Bridge Navigational Watch Alarm System BNWAS e 1 0 Generals e 1 1 Installation gt 2 1 Manual Switch On e 22 Automatic Switch On e 3 0 Select dormant main period e 3 1 Reset of dormant main period e 32 Alert sequences start automatically e 3 2 1 Visual indications e 3 2 2 Alarm stage 1 e 3 2 3 Alarm stage 2 e 3 2 44 Alarm Stage 3 gt 4 1 Emergency Call e 5 1 System shut down 1 0 Generals The purpose of a bridge navigational watch alarm system is to monitor bridge activity and detect operator disability which could lead to marine accidents The system monitors awareness of the Officer of the Watch OOW and automatically alerts the Master or another qualified person if for any reason OOW becomes incapable of performing OOW s duties This purpose is achieved by series of indications and alarm to alert first the OOW and if he is not responding then to alert Master or another qualified person Additionally the BNWAS provide the OOW with means of calling for immediate assistance if required This user manual short version is made for persons who know basic standards of watch alarm system All time period reset inputs are protected against permanent reset U WAS 2000 User Manual R01 06 32 39 Martechnic Ltd 30 210 4227267 1 1 Insta
16. atch Alarm System owns a test mode procedure to check all output relevant devices alarm panels external buzzers links to alarm devices links to VDR and system failure contact in a very comfortable manner To reach this service mode an authorized person has to switch off system by turning key switch S1 on operating device LOD 210 24 0 0 to position ON OFF for longer than 2 sec System shuts down After that authorized person has to keep pushing rotary encoder push button S2 and after a period between 2 and 3 sec he has to switch on system by turning key switch S1 on operating device LOD 210 24 0 0 one time to position ON OFF key switch ON OFF S1 2x16 character WA TCH ALARM SELECT illuminated display U WAS 2000 UMAR SHIPPING SERVICES rotary encoder incl operating device push button S2 LOD 210 24 0 0 System starts in service mode and display is showing text 4 display text 4 TEST MODE 1 OFF ALARM on BRIDGE By pushing rotary encoder s push button S2 for one time all internal and external bridge area alarm devices alarm stage 1 are activated as long as push button S2 is pushed again During this manual alarm activation display is showing text 5 display text 5 TEST MODE1 ON ALARM on BRIDGE U WAS 2000 User Manual R01 06 8 39 Martechnic Ltd 30 210 4227267 After a m test in test mode 1 is done user has to turn rotary encoder clockwise to reach test mode 2 display text 6
17. box part background white symbol black sound code 11100 SIGNAL DEVICE WITH SOUNDER amp TRIANGLE LIGHT FOR WATCH ALARM TYP A STAND E Martechnic Ltd 30 210 4227267 1 A 0 gt VE sp surface black anodized C NP print white RAL 9010 nominal values 24VDC 50mA degree of enclosure IP 23 core size max 2 5mm sounder 80 dB A depth 45mm 2 weight 0 150kg M 1 1 Teile Nr INDEX FELD NDERUNG ND MITT DATUM NAME 2004 TAG NAME on WATCH ALARM PANEL WAP 220 2 0 0 12 reit for Offi bi GEPR or Icer s cabin NORM amp 18 Sez Se s es e lh SE hes les jo U M AR AUFTRAG NR TYP A STAND E ZND SHIPPING SERVICES standard BLATT 1 VON 1 U WAS 2000 User Manual R01 06 24 39 Martechnic Ltd 30 210 4227267 18 UMAR SHIPPING SERVICES OL JNE HOLE INSTALLATI LI U WAS 2000 User Manual R01 06 25 39 Martechnic Ltd 30 210 4227267 SHIPPING SERVICES OLOUR U WAS 2000 User Manual R01 06 26 39 Martechnic Ltd 30 210 4227267 WATCH ALARM M32x1 5 wallbox surface
18. er in clockwise direction to increase time period value or in counter clock wise direction to decrease time period value System allows only values between 90 and 180sec By pushing rotary encoder s push button S2 on operating device LOD 210 24 0 0 display is changing and system accepts adjusted value U WAS 2000 User Manual R01 06 16 39 Martechnic Ltd 30 210 4227267 8 adjust buzzer characteristics amp volume U WAS 2000 system is designed with adjust mode to be able to change steady internal and external alert tone into 7 additional individual buzzer characteristics in case other systems on bridge area are generating a similar alert tone Adjust buzzer s characteristic To adjust buzzer s characteristic turn key switch 51 on operating device LOD 210 24 0 0 to position SELECT AUTO WA TCH ALA RM SELECT key switch 2x16 character U WAS 2000 51 illuminated display UMAR SHIPPING SERVICES operating device rotary encoder incl LOD 210 24 0 0 push button S2 After turning key switch S1 to position SELECT display is showing text 3 display text 3 SET MAIN PERIOD 3 12min 3 Now push rotary encoder s push button S2 on operating device LOD 210 24 0 0 so often as display is showing text 22 display text 22 BUZZERs PROPERTIES 1 Now turn rotary encoder to choose an adequate buzzer characteristic By pushing rotary encoder s push button S2 display is changing and system accepts adjusted value
19. in such manner service personnel is able to see state LEDs on module Operating device LOD 210 24 0 0 is designed to be installed on control console Operating device and all time period reset units have to be installed only at locations on bridge or bridge wings where OOW has a proper look out Installation must conform to regulations for electromagnetic compatibility EMC see chapter technical data amp schematics U WAS 2000 User Manual R01 06 2 39 Martechnic Ltd 30 210 4227267 2 installation Connecting module LCM 210 24 0 0 and its extension devices time period reset units alarm devices have to be connected according to corresponding wiring diagrams fuse holders F1 F2 m2A C ACT 505000 EEG 15 pole connector to operating device 300 00 0000000 0 0 0 000 0 0 06 0 008 terminals for terminals for 24VDC power supply connecting module periphery equipment LCM 210 24 0 0 description connecting module LCM 210 24 0 0 Module has been designed to click on terminal rail TS 35 inside electric cabinet or control console All periphery equipment time period reset units alarm panels power supply is to be connected directly on connecting module without any additional terminal board or distribution boxes according to wiring diagram which is part of working drawings Sample system wiring diagram is shown in chapter technical data amp schematics Outputs for power on indication and time per
20. iod reset push button illumination are short cut protected Maximum loads of outputs and output contacts see chapter technical data amp schematics U WAS 2000 User Manual R01 06 3 39 Martechnic Ltd 30 210 4227267 key switch AUTO _ 2x16 character WATCH ALARM S1 illuminated display SELECT U WAS 2000 UMAR SHIPPING SERVICES rotary encoder incl push button S2 operating device LOD 210 24 0 0 operating device LOD 210 24 0 0 Before mounting operating device into cut out plug on 15 pole system cable on device s rear side and tighten it properly Use device clamps to fix device in proper manner Do not use longer system cable as standard length I 3m Plug on 15 pole system cable on connecting module LCM 210 24 0 0 Z1 and tighten it properly After connecting all additional equipment time period reset units alarm devices according to corresponding wiring diagram system is ready for operating U WAS 2000 User Manual R01 06 4 39 Martechnic Ltd 30 210 4227267 3 commissioning Before switching on 24VDC nominal power supply to connecting module LCM 210 24 0 0 terminal board X1 1 2 amp 3 4 make sure power supply time period reset units and external alarm devices have been connected correctly according to wiring diagram Diode on LCM 210 24 0 0 connecting module secures system against wrong power supply polarity 338 3000 0 0000000 00 000 0 0 06 HOS D CA seosoe08000000060800
21. llation After operating device LOD 210 24 0 0 and connecting module LCM 210 24 0 0 are installed according to technical documentation by authorized personnel system has to be supplied by 24VDC battery power supply terminal board X1 1 3 Potential free n o failure contact connecting module X1 5 6 closes and system is ready for switch on After a short display intro display on operating device is showing text 1 display text 1 READY FOR POWER ON AUTO 2 1 Manual switch on Authorized person Master switches on system by single turning key switch S1 on operating device to position ON OFF System s running is indicated by activating last chosen dormant main period and count down is active as shown on display text 2 display text 2 COUNT DOWN wet 2 50 te AUTO WATCH ALARM key switch 2x16 chara U WAS 2000 P illuminated display UMAR SHIPPING SERVICES rotary encoder incl operating device ce SE LOD 210 24 0 0 If dormant main period 3 12 min shall not be changed authorized person Master pull off the key Dormant period is counting down from the moment that system has been switched on Dormant period is period within OOW is monitored but no further alert is triggered U WAS 2000 User Manual R01 06 33 39 Martechnic Ltd 30 210 4227267 2 2 Automatically switch on System can be switched on by external systems via potential free steady n o contact which has to be connec
22. n date name norm spare of department sme WATCH ALARM SYSTEM GL LCM 210 24 0 0ASREVB 1 sh U WAS 2000 User Manual R01 06 20 39 Martechnic Ltd 30 210 4227267 72 2 835 WATCH ALARM AUTO SELECT 144 5 669 136 5 354 61 61 75 _ 8 5 2 425 2 952 0 335 CLAERANCE 415 121 5 _ 0 591 4 783 CUT OUT 139 0 2 5 472 68 0 2 2 677 CONSOLE MATERIAL max t 8 0mm 0 315 panel surface black polycarbonat print RAL 9010 degree of enclosure EN 60529 IP22 front sided evenness of mounting surface lt 0 1mm to keep degree of enclosure weight 0 200kg power supply 18 0 31 2V power consumption max 8 2W nominal 4 0W UMAR SHIPPING SERVICES AT AME x E ART No _______ feat AS OPERATI EVICE IMENSIONAL AWING mm INCH Nal ars NWS D 1 A qup A te AUFTRAG NR TYP A STAND E ART l no U WAS 2000 User Manual R01 06 21 39 Martechnic Ltd 30 210 4227267 5 n 9
23. nsistor outputs max load of relay contacts sound pressure level U WAS 2000 BNWAS 24VDC nominal 18 0 31 2VDC nominal feeding value B4A min 60mA max 400mA nominal value 120mA 2x m2 0A 5x20mm acc EN 60529 see table connecting module 330g operating device 200g design amp manufacturing acc IEC 60945 type approvals GL power on indication max 400mA reset pb illumination 2x 180mA 30VDC 2A internal buzzer 65 80dB A adjustable degree of safety distance cable no type description weight kg enclosure en bros actos spare parts console mounted operating device with blue illuminated display douce men operating device da 0 200 IP22 1 key switch and rotary encoder with integrated push button 0 5 LOD 210 24 0 0 Ww 144 h 72 x d 75mm cable back 0 300 IPOO connecting module terminal board module to be mounted on terminal rail TS35 2 2x micro fuse m2 0A 5x20mm 2 LCM 210 24 0 0 w 162 xh 127 x d 68mm 9 990 icu 0 5 part no 097109 front 3 WAP 2202 00 watch alarm panel for officer s cabin 80 dB A 0 150 Ires 0 2 2 5mm 1x bulb mg28V 40mA flush mounting back part no 099081 IPOO watch alarm panel for officer s area corridor 64 111dB A 21x bulb E14 24V AW bulkhead or flush mounting 0 870 IP65 Bids part no 099141 watch alarm reset push button illuminated 0 2 1x bulb T5 5
24. ry encoder s integrated push button S2 on operating device during his actual work on bridge area Every reset is re starting complete count down independent of its U WAS 2000 User Manual R01 06 34 39 Martechnic Ltd 30 210 4227267 moment To serve rules of ergonomics several reset units should be placed on strategic locations on bridge and bridge wing area These reset units are maximum sized illuminated push buttons as well as loud electronic sounder which have been connected on connecting module LCM 210 24 0 0 3 2 Alert sequences start automatically 3 2 1 visual indications If dormant main period is over without OOW s reset system activates all illuminated reset units by 1Hz flash light Display is showing in 1Hz toggle mode display text 12 and text 13 display text 12 RESET EXPECTED 0 14 display text 13 RESET EXPECTED kkkkkkkkk 0 1 3 kkkkkkkkkk All illuminated push buttons and display on operating device are centralized dimmable via rotary encoder S2 on operating device Minimum illumination is fixed 3 2 2 Alarm stage 1 If dormant main period and flash light period 4 2 1 15 sec are over without OOW s reset System activates internal electronic buzzer as well as additional buzzers located on bridge or bridge wing area Display is showing in 1 Hz toggle mode display text 14 and text 15 display text 14 RESET EXPECTED 0 14 display text 15 Aaa Seats 1 U WAS 2000 User Manual R01 06 35 39 Martechnic
25. s in officer s area as well as for VDR link 4 1 Emergency call Monitored OOW is able to generate an emergency call by pushing any reset unit longer than 5 sec That activates without delay alarm stage 2 and subsequently alarm stage 3 later on Display on operating device is showing in toggle mode display text 20 and text 21 display text 20 EMERGENCY CALL 1 29 display text 21 OFFICERs ALARM 1 28 Notice Emergency Call feature is not activated when system is shut down see chapter 5 1 System shut down Emergency Call reset is possible by pushing any reset unit U WAS 2000 User Manual R01 06 37 39 Martechnic Ltd 30 210 4227267 5 1 System shut down If system is not in operation and external automatic system on should not be possible Master is able to shut down system by turning key switch S2 on operating device for longer than 2 sec to position ON OFF Display shuts down and system ignores all external inputs now system is shut down Notice When system is shut down no emergency call is possible AUTO 2x16 character WATCH ALARM illuminated display U WAS 2000 UMAR SHIPPING SERVICES operating device LOD 210 24 0 0 fuse holders F1 F2 rn 1 5 X 3X2 X X 3 e 2922205 CCIE connecting module terminals for LCM 210 24
26. ted on connecting module LCM 210 24 0 0 X1 29 amp 30 Automatic switch on is possible only in automatic mode when display is showing text 1 READY FOR POWER AUTO In case automatic switch on shall not be possible master has to shut down system see display text 1 chapter 5 1 System shut down 3 0 Select dormant main period In case that authorized person Master demands to select other dormant period person has to turn key switch S1 on operating device to position SELECT In this position only dormant period can be chosen by using rotary encoder S2 on operating device Display is showing text 3 display text 3 SET MAIN PERIOD 3 12min 3 By turning rotary encoder S2 in clock wise direction value is increasing By tuning rotary encoder S2 in counter clock wise direction value is decreasing Possible main period value is limited between 3 and 12 min Step width is 1 min By turning key switch S1 into centre position system accepts new value and count down starts from the moment the key has turned into centre position Authorized person Master can pull off key only in centre position Dormant main period 3 12 min shows after which period automatically generated alert sequences will be triggered see user manual time table page 20 3 1 Reset of dormant main period As a rule monitored person OOW resets dormant period by pushing illuminating push buttons or rota
27. this manual alarm activation display is showing text 11 display text 11 TESTMODE4 ON DEVICE FAILURE State of all output relays is shown by corresponding control LEDs Consider reversed relay logic of system failure relay K1 MVOC noma e oc as To 8 connecting module all Al 2 2 LCM 210 24 0 0 zur 0100000 600 ee alarm stage 1 relay alarm stage 3 relay K2 with control LED 2 K4 with control LED 4 system fail relay alarm stage 2 relay KI with control LED 1 K3 with control LED 3 U WAS 2000 User Manual R01 06 10 39 Martechnic Ltd 30 210 4227267 For finishing test mode procedure switch off system by turning key switch S1 on operating device LOD 210 24 0 0 to position ON OFF key switch AUTO S1 2x16 character WA TCH ALARM ON OFF illuminated display SELECT U WAS 2000 UMAR SHIPPING SERVICES rotary encoder incl operating device push button S2 LOD 210 24 0 0 U WAS 2000 User Manual R01 06 11 39 Martechnic Ltd 30 210 4227267 5 trouble shooting EN 2 DERE AL 8 n 111 E 2e 1 0 000 0 0 0 0 0 0 0 0 0 0 0 0 05 0 9 zum 29 020000000 Sr O connecting module LCM 210 24 0 0 system fail relay K1 with control LED 1 system fail criteria In following cases potential free dry n o contact on connecting module LCM 210 24 0 0 X1 5 6 opens system fail state a
Download Pdf Manuals