Home

HRU ECO 4 - Denmans Electrical Wholesalers

image

Contents

1. HRU ECO 4 System 4 Continuous Mechanical Supply and Extract Ventilation with Heat Recovery Appendix O Eligible Application This high efficiency MVHR unit is ideal for all new build dwellings especially those being built to a higher standard of air tightness Description The HRUECO4 is a high efficiency heat recovery unit It has a sophisticated counter flow heat exchanger which can recover up to 91 of the heat from the discharge air This recovered heat is used to pre heat the fresh air being brought in from outside Models The table below lists the models available Housing The units for houses and apartments Table 1 Connections to the dwelling have the same design The only differences are in the layout of the duct connections and motor modules With units for houses the air supply is situated at the lower part of the unit In units for apartments the air supply is situated at the upper part The motor module seals the opposite connection The connections on both the lower part of the unit and the upper part can be used for air extract Unused connections are sealed with a cap Because of the unique patented clamp construction of the HRU ECO 4 the sealing of the different parts will be optimised Therefore there will be no internal or external leakage The unit can be easily reversed when dwelling designs are mirrored Connections to atmosphere We
2. Mounting The unit must be fixed with the mounting bracket to a wall with a mass of no less than 200 kg m Points of Attention To ensure a good installation please pay attention to e Moisture resistent insulated exhaust duct to outside min internal diam 150 mm e Damp proof thermal isolated fresh air inlet duct from outside min internal diam 150 mm e Air inlet duct to dwelling min internal diam 150 mm which can be split up in two ducts internal diam 150 mm e Exhaust duct from the dwelling min internal diam 150 mm e Apply the provided sound insulating flexible pipe type FGD 180 50 D 180mmm L 500mm between the air supply to the dwelling and the unit e Condense drain with water seal replenishable for a water block between the unit and the place where the unit is mounted and the waste pipe e Mains supply must be 230V AC Access to the Unit The unit should be located so that it can be easily accessed for servicing To enable easy servicing of the filters and heat exchanger there must be a space of not less than 50 cm in front of the unit Important Make sure that nothing is placed on top of the automatic frost protection valve As when the valve opens a foreign object falling in would prevent the mechanism from working Installation and User Manual The installation and user manual are delivered with the unit Make sure to read these manuals before installing or using t
3. I u rufaarzi WATT an PTT FEU GE niet warm ali Th Aer The automatic frost protection device works as follows e The valve is open modulating and extracts some air from the area in which it is installed The air is mixed with the fresh air e At the same time the supply fan will increase fan speed to keep the fresh air volume at the same level e When the temperature drops the supply fan will decrease fan speed variably until a minimum is reached e Whilst the temperature is still decreasing the exhaust fan will speed up and the supply fan will slow down e With extreme low temperatures the supply fan is turned off the frost protection device will be closed but the exhaust fan will keep on working After approx 1 5 hours the air supply fan will start at a minimum speed and the frost protection valve will be opened to check whether the danger of freezing is gone When the temperature rises all above mentioned steps will be carried out in reverse order All the above procedures will be carried out automatically Removing the Heat Exchanger Motors The HRU ECO 4 is provided with two energy efficient DC motors The impellers have backward curved blades which help to keep it clean maximising the capacity of the supply and extract fans Capacity Setting In the connection unit of the HRU ECO 4 are two potentiometers which allow for adjustment of both the low speed and high spe
4. Step 3 High 225 150 100 0 79 230 0 55 94 Step 3 High 275 100 121 0 95 230 0 55 93 Step 3 High 275 150 139 109 230 0 55 93 Step 3 Max 325 100 172 1 32 230 0 56 92 Step 3 Max 235 150 200 1 45 230 0 58 92 Values to be used in the EPC calculation at 230V according to NEN5128 Other technical specifications Power supply 230V Condensate discharge diameter 40mm external Frequency 50Hz Protection P31 Dimensions height 848mm Filterclass G3 width 730mm depth 479mm Technical Specifications Sound Power Spectrum 63Hz ij zy 250Hz 500Hz 1000Hz 2000Hz 4000Hz total Breakout 325 m h 150 Pa 22 36 49 56 58 55 50 62 Breakout 275 m3 h 150 Pa 20 24 48 57 56 51 46 60 Breakout 225 m h 150 Pa 19 31 47 57 54 47 42 59 Breakout 150 m3 h 80 Pa 13 26 42 45 45 39 30 50 Breakout 75 m3 h 20 Pa 5 19 31 31 31 26 15 36 Exhaust 325 m h 150 Pa 41 43 55 54 51 44 30 59 Exhaust 275 m3 h 150 Pa 39 41 54 52 48 41 27 57 Exhaust 225 m h 150 Pa 37 38 53 50 46 37 23 56 Exhaust 150 m3 h 80 Pa 32 33 47 42 38 29 16 49 Exhaust 75 m3 h 20 Pa 28 26 27 22 19 12 15 33 Inlet 325 m3 h 150 Pa 45 57 64 69 68 62 58 73 Inlet 275 m3 h 150 Pa 46 56 63 69 66 60 55 72 Inlet 225 m h 150 Pa 48 55 63 69 64 58 52 71 Inlet 150 m h 80 Pa 45 50 55 57 52 46 39 61 Inlet 75 m3 h 20 Pa 40 40 40 38 36 30 19 46 Capacity qv dm3 s a 1a 30 j 40 50 Bo 70 Ba Ed op na A PRE a m z s SE
5. be fitted with a minimum contact gap of 3mm Since the unit is double insulated it does not need to be earthed As standard the electrical connection on the unit is positioned on the left hand side When the unit is reconfigured for opposite installation the electrical connection will be positioned on the right hand side Control The heat recovery unit HRU ECO 4 can be ordered with a choice of optional control units e Wired 3 step control e Wireless RF 3 step control unit with timer Wired 3 way switch This wired control unit can be connected to the connection box of the unit see wiring diagram RF 3 Speed Controller 2 3 te R RF 3 speed Control If the heat recovery unit is provided with a wireless radio frequency remote control switch The receiver for the control signal is fitted into the fan during factory production The switch which has a self adhesive backing should be located in the wet rooms most likely the kitchen or bathroom within the house and can switch the unit between speed position one two and three Additional transmitters are available to allow the fan to be controlled from more rooms the utility room en suites etc The last used switch is the master Advantages of Wireless Control e No drilling fixings or electrical wiring is necessary e Control from every room is possible e Additional switches can be added at any time e A better indoor z climate by
6. optimal control F Type RS3i built in gt Installing RF Control Unit To install the RF control switch unit in the kitchen just adhere the control unit on to a tile with the supplied double sided adhesive tape Alternatively the control unit can also be fixed with a screw Each unit is supplied with an installation and user manual Do not place the RF control switch on a metal surface Additional RF Control Switch Information e Transmission range 100m in free air e Transmission indoors is possible through a maximum of 2 concrete floors Wiring Diagrams HRU ECO fan 4 BV I BV H Green Yellow 3 scores switch RS3i With an RS3i Speed Controller e Pointing of transmitter towards the fan is not necessary e No external antenna e Frequency 868 MHz no licence required Timer Function A timer function is also included on the RF control switch This timer can be used to switch the ventilation to the highest speed for a period of time for instance after an occupant has used the bathroom The advantage is that after the run on period of the timer the fan will revert back to its original speed Pressing the timer button once will switch the fan to high speed for 10 minutes Pressing the timer button a second time will switch the unit to high speed for 20 minutes and a third press of the button will switch the unit to high speed for 30 minutes The timer function can be over r
7. specific fan power SFP of 1 0 W L s or less and a heat recovery efficiency of 85 or above These figures have been both reached and exceeded by the HRU Tesi repat SAP Appendix O WVHA Test report Humbe 244 174 Standard Assesament Procedure 2005 Appendix O MVHR Product Data Product brated HAW ECO d Results for Appendix Q ai minimum flow rate condtian Tabla O2 Systems with ngi ductwork only ECO 4 a credit to Itho s continued and to aspire to go that extra mile technological advancements Following years of experience in having to meet continually tightening The Energy Saving Trust s Best Practice demands Itho always aims to stay one standards along with The Code for step ahead and continues to offer Sustainable Homes both offer valuable ventilation solutions that exceed current guidance toward sustainable home expectations building and offer the industry the chance to exceed Government targets 15 Energy efficient climate control systems that add to your comfort Itho proves it can be done Wherever you are live and work chances are that you will be confronted with the products and services of Itho nearly every day This is because we develop climate control systems for all those places where people are working ranging from houses to offices and industrial units from shops to restaurants and from sports complexes to hotels and museums Whenever and wherever the residents u
8. warmth from the extracted air defined systems of ventilation to path through the property from the dry is transferred to the incoming fresh dwellings System 4 Continuous habitable rooms air before it is supplied to the mechanical supply and extract with heat habitable rooms recovery MVHR is complied with by the new HRU ECO 4 RF ultra high efficiency whole house heat recovery ventilation system System 4 Continuous Mechanical Supply amp Extract with Heat Recovery requires a minimum high rate in each wet room to be achieved kitchen 13 l s and both utilities and bathrooms 8 l s sanitary only 6 I s In employing this type of system there is no need to install background ventilators in the dwelling an ideal solution to noisy sites The minimum low rate is calculated by taking the number of bedrooms in the dwelling and applying the l s value from Table 1 1b In addition the rate should be no less than 0 3 I s per m of internal floor area all storeys plus for each additional occupant over and above the anticipated two for the first bedroom and one for each of the others a further 4 s must be added to the extract rate Also there is an addition of an allowance to be calculated for air infiltration Building Regulations system 4 CONTINUOUS MECHANICAL SUPPLY amp EXTRACT VENTILATION WITH HEAT RECOVERY A continuous balanced mechanical central supply and extract system to
9. Accommodation 6 l s in table 1 1B Table 1 1 B Number of bedrooms in dwelling 1 2 3 4 5 Whole Building Ventilation Rate l s 13 17 21 25 29 Minimum value in any dwelling of 0 3 I s per m floor area In addition the minimum ventilation rate should not be less than 0 3 I s per m internal floor area this includes each floor e g for a two storey building add the ground and first floor areas This is based on two occupants in the main bedroom and a single occupant in all other bedrooms This should be used as the default value If a greater level of occupancy is expected then add 4 l s per occupant SAP Appendix O Eligible The HRU ECO 4 is SAP Appendix Q Eligible proving it to be one of the most energy efficient MVHR units available Designed to calculate the energy performance of Dwellings the Standard Assessment Procedure SAP Appendix O website www sap appendixq org uk isa UK based Government led initiative used to demonstrate compliance with building regulations within the following areas Part L England and Wales Section 6 Scotland and Part F Northern Ireland providing energy ratings for dwellings that can be compared nationally Here are the relevant independent BRE test results for the HRU ECO 4 As featured in the Energy Saving Trusts Demonstrating Compliance Best Practice in order to meet reduced CO2 emission targets MVHR units have been set certain standards and must have a
10. PTE PSE PZ i a maa mm g wn gt O T a jm U z a o get m e m T d iS K ie mm 7 SS 4 8 a A a ia ae ee K u WIE m Ai BET GE 2 i a o am e 75 100 WS wo 195 100 am men mm joo mp 380 375 460 1 capacity min 2 capacity low 2 capacity middle A capacity high 5 capacity max Freres 6 power min taaita 7 power low orem 3 power middle Trap 9 power high tki 10 power max 10 Dimensions Suspension Mirrored suspension 600 848 848 I 180 300 a 300 180 DEFROGT VALWE ACCESS TO CLEAN YPAGS FIL PREM AN STAKE BYP TER FROM ATMOGPHLAE rath EXHAUST P a 4 TO ATMOSPHERE F G ba R i P j m ch Le Air TO DWEL LING Lat W e HG BARL DING Le e el af SE er Lei ri e FROM DWELLING wa 4 CONNECTIONE Ri i TER LI d bk b TO DW Be DETAL CAGES SECTION EUSPENEKON TOP YEW SCALE ii 11 12 Building Regulations The 2006 Edition of the UK Building The system provides quiet uninterrupted Air drawn into the property by the fan Regulations Approved Document F1 extract ventilation from the dwelling is routed through an integral high Means of Ventilation applicable in removing warm stale air via all of the efficiency synthetic heat exchanger England and Wales details four clearly wet rooms creating a permanent air where
11. be positioned in loft or cupboard space An integral heat exchanger recovers a large percentage of heat energy that would have otherwise been lost In employing this type of system there is no need to install background ventilators in the dwelling CONTINUOUS SUPPLY AND EXTRACT 1 Determine the whole building ventilation rate from Table 1 1B Allow for infiltration by subtracting for multi storey dwellings 0 04 x gross internal volume of dwelling heated space m3 for single storey dwellings 0 06 x gross internal volume of dwelling heated space m 2 Calculate the whole dwelling extract rate at maximum operation by adding the individual room rates for minimum high rate from Table 1 1A 3 The required air flow rates are as follows Maximum Extract Rate boost is the greater step of 1 and 2 above The minimum individual room extract rates should be at least those given in Table 1 1A for minimum high rate Minimum air supply rate should be at least the whole building ventilation rate in 1 above 4 No background ventilators are required with System 4 Table 1 1A Room Minimum Intermittent Extract Rate Continuous Rate Minimum high rate Minimum low rate Kitchen 30 l s adjacent to hob or 60 l s elsewhere 13 l s Total extract rate Utility Room 30 l s 8 s must be at least the whole building Bathroom 15 1 5 81 5 ventilation rate Sanitary
12. ed The mid position is an automatically calculated value between low and high The factory setting for high position is 225 m h To ensure the best energy efficiency this potentiometer should not be touched unless the required volumes cannot be reached when room grilles are set in their fully open position Filters The HRU ECO 4 has as standard two G3 filters One of the filters is placed between the exhaust duct from the house and the heat exchanger The filter ensures that dust and grease are absorbed and the heat exchanger will become less dirty The other filter is situated between the fresh air inlet and the heat exchanger This filter ensures that fresh air is filtered before it is supplied into the dwelling It also prevents the heat exchanger from becoming dirty Both filters can be easily removed cleaned and replaced by the occupant without the need to remove the front cover Appendix Q Eligible The HRU has been tested at BRE and is certified as being an Appendix Q Eligible product This means that the test results which are available on www sap appendixq org uk can be used to help improve SAP rating Installing The heat recovery unit HRU ECO 4 is designed to be installed in different types of dwellings from small apartments to larger houses The unit can be placed in different places in the dwelling like e In the loft in a closed room e In a closed storage room e In an airing cupboard
13. he unit If required the installation manual can be obtained from Itho Ventilation Limited prior to delivery of the unit Easy access Maintenance The maintenance ofthe unit involves only the following e Clean the filters when the dwelling is completed These filters may be dirty because of building materials e Clean the filters every 6 to 9 months e Replace the filters at least once a year e Clean the heat exchanger every six years e Depending on the pollution also clean the motor and fan blade G4 filter New filters are available in sets Spare parts can easily be exchanged without tools e The filters can now be changed without taking the cover off e The heat exchanger can also be reached by removing the front cover e The complete service module motors fans power supply and controls can be removed or replaced without disconnecting the ducts e Data can be read by connecting a laptop with service software Warranty The unit has a guarantee period of 2 years from date of installation Accessories A heat recovery system consists of different components The heart is the HRU ECO 4 More information about ducting and other system components can be obtained from Itho Ventilation Ltd Electrical Connection The HRU ECO 4 can be connected to a 230V 50Hz supply A flying lead is attached to the unit as standard When installing the unit a double pole isolation switch must
14. idden at any time by pressing either of the three speed buttons HRU ECO fan 4 BV BV H Green Yellow 1 Low 2 Middle A High L 230V 50 Hz supply With a 3 way switch by others With an in depth knowledge of current UK Building Regulations England Wales Scotland amp Northern amp Southern Ireland all plans are guaranteed to comply with all current legislations For those in need of CPD level courses the following are currently available e Energy Efficient Ventilation amp the future of ventilation systems e Importance of Installation Practice to Maximise System Performances EET With the ability to both send and receive all plans electronically and manually this free design service has been specifically developed to help make your life easier To find out more please forward your request to info itho co uk Schiedam Head Office and Factory visits can be arranged for key industry personnel and provide the perfect arena to learn more about Itho s history and their continued drive for improvement Technical Specifications Wj a D f H Capacity Pressure Current Voltage Cos phi Technical m3 h Pa AJ MAK efficiency Step 1 Min 50 10 10 0 07 230 0 63 98 Step 1 Low 75 20 14 0 094 230 0 65 98 Step 2 Medium 150 40 39 0 32 230 0 53 96 2 Step 2 Medium 150 80 45 0 37 230 0 54 96 2 Step 3 High 225 100 86 0 69 230 0 54 94
15. ide upper side 225 m3 h 325 m3 h 100 Summer Bypass Valve The heat recovery unit has a Summer bypass valve which is completely integrated in the unit The bypass valve diverts the air supply completely around the heat exchanger This means the exit air from the dwelling does not heat this fresh air trikes fresih ali PT warm KF PLT A kil i Thy fink bs wale l L te od inai ai F ert len exact vedrim AN fram hours mier Mesh ali Io ho Especially during summer nights this bypass valve is desirable because the outside temperature is often lower than the temperature inside The fully automatic temperature controller makes sure the bypass valve being opened when e The inside temperature is higher than required not adjustable e The inside temperature is higher than the outside temperature e The outside temperature is for a longer period gt 19 C period depends on the exact temperature Both the inside and the outside temperature is measured inside the HRU ECO 4 by two integral sensors Frost Protection Device To prevent the heat exchanger from freezing a unique mechanism is standard in the HRU ECO 4 This mechanism consists of a valve integrated on the upper part of the unit Leder iah aii Fila kal wiki air a bal Pusat wn alt Terre PHE h Phin coed a la airregph te protection vale d WI value mier AM Fit Lesen
16. ight As a result of the unique clamping construction in combination with the plastic synthetic elements the weight of the heat recovery unit HRU ECO 4 is only 25 kg Exhaust and Supply Connections All exhaust and supply connections have an internal diameter of 150 mm and external 180 mm The connections can be used to attach modular plastic and metal ducts accessories directly Each connection is stamped with an embossed indicator which shows both the direction and source ofthe air Counter Flow Heat Exchanger The unique heat exchanger is based on the principle of counter flow One of the characteristics of this heat exchanger is that the incoming and outgoing air is moving via triangular canals Thus each canal is surrounded by canals in which the airflow is opposite This creates an enormous surface area to exchange heat This special construction is one of the reasons why up to 91 thermal efficiency can be reached Inlet and exhaust capacity HRU ECO 4 Appliance House 5 Core Cable Exhaust bottom upper side bottom Exhaust upper side upper side Standard 225 m3 h 325 m3 h Pressure HRU ECO 4 House RF bottom upper side bottom upper side upper side 225 m3 h 325 m3 h HRU ECO 4 Apartment 5 Core Cable upper side upper side upper side upper side 225 m3 h 325 m3 h HRU ECO 4 Apartment RF upper side upper side upper s
17. sers and owners of all these buildings ultimately have the same two wishes On the one hand they want the highest possible comfort On the other they want the lowest possible consumption in energy These demands appear to be contradictory However here at Itho we set ourselves the objective to prove that these two demands can be combined We possess the professionalism drive and innovative power needed to actually deliver the evidence through figures test results and particularly through satisfied and enthusiastic clients and users Itho Ventilation Limited 10 Faraday Court First Avenue Centrum 100 Burton on Trent DE14 2WX T 0870 460 6741 F 0870 460 6742 E info itho co uk www itho co uk D n O R L og O N O 00