Home
T2X manual.pmd - Moore Industries International
Contents
1. 0 35 in ial t l Pe DIA 72mm FRONT DIA 2 85 in Simm BORIOM M4 0x0 7 INSIDE nstrument 2 0 in 4 places Mounting Holes i 1 56 in f Metal Tag Z 61 Instrument N Mounting 2 4 in Halos 33mm 3 07 in Mounting Holes 2 I D 62mm x 19mm Deep Process Connection 2 43 in x 0 76 in Deep 1 2 in NPT N and M models or G12 BSP C models 2 INCH PIPE MOUNTING HARDWARE 2 in Pipe Bracket Mounting Holes 4 lt 2 4 in WORLDWIDE e www miinet com Belgium info mooreind be Tel 03 448 10 18 FAX 03 440 17 97 The Netherlands sales mooreind nl Tel 0 344 617971 FAX 0 344 615920 China sales mooreind sh cn Tel 86 21 62491499 FAX 86 21 62490635 United Kingdom sales mooreind com Tel 01293 514488 FAX 01293 536852 Specifications and information subject to change without notice
2. Minimum Span Maximum Range Conformance Type REUL 100 200 100 to 650 C 150 to 720 C 400 500 148 to 1202 F 238 to 1328 F 0 003902 1000 100 to 300 C 150 to 300 C 148 to 572 F 238 to 572 F 200 to NEE 240 to icin C 80 to E E 3 to Ore 50 to aO 203 19 to 300 C 100 C 100 200 200 to 850 C 240 to 960 C 300 400 500 328 to 1562 F 400 to 1760 F 0 003850 MAEHE 328 to 572 F 400 to 572 F Platinum 180 F Potentiometer Transmitter will measure ranges outside of the Conformance Range with some degradation to accuracy ratings Consult the factory for details The Interface Solution Experts www miinet com according to IEC 61326 Noise Rejection Common mode 100dB 50 60Hz Normal Mode 70dB typical at 200mV peak to peak 50 60Hz All settings are made using Moore Industries Intelligent PC Configuration Software and then stored in nonvolatile memory HPP 101 g 3 6 oz HPP in LH1 428 g 15 1 oz HPP in LH2 654 g 1 Ib 7 oz HPP in CH6 173 g 6 1 oz Configuration Software and Cable Each T2X order comes with one copy of our Configuration Software Windows 95 98 NT 2000 and XP compatible To order additional copies Software PART NUMBER 750 75E05 01 PC to Transmitter Configuration Cable PART NUMBER 803 040 26 TEMPTATION 2000 T2X RID Temperature Transmitter Installing and Connecting the T2X Now that the T2X has been programmed to
3. Type values Continue to change the remaining areas in Input Type such as ohms and wires until the entire Input Type area matches the desired parameters for your transmitter 2 Scaling the Input amp Setting the Reverse Output Scaling the input allows you to set the T2X to scale its output in re sponse to a portion of the total range of the selected input type Ina reverse output application the T2X output drops in proportion to a rise on input and rises in proportion to a drop in the input To scale the input To set the scaling select the Input Zero box and enter the value for the desired Input Zero from the application where the T2X is to be employed Select the Input Full box and enter the value for the desired Input Full To set reverse output Follow the instructions to scale the input but enter a value in the Input Zero box that is greater than the Input Full and a value in the Input Full box that is less than the Input Zero 3 Scaling the Output The T2X can be configured to scale its 4 20mA output to offset the performance or calibration of other instruments in the process loop To scale the output enter the desired Output Zero value in the Zero Scale Output box or use the slide bar to adjust the value Select the Full Scale Output box and enter the desired Output Full value 4 Setting Miscellaneous Functions There are several radio buttons on the T2X Configuration Program Main Screen that control
4. Ui moore INDUSTRIES November 2013 TEMPTATION 2000 T2X RTD Temperature Transmitter Temperature Transmitters You Can t Resist The TEMPTATION 2000 rtp Temperature Transmitter Model T2X delivers long term stability in a wide range of basic temperature sensing applications The PC programmable microprocessor based T2X accepts 2 3 and 4 wire RTD inputs It provides a proportional 4 20mA output that is linear with temperature and ready for direct interface with a monitoring control system Setting up the T2X Configuring and programming the T2X is simple Begin by gathering all the necessary equipment as listed in Table 1 installing the T2X PC Configuration Program onto your computer then connecting the T2X as shown in Figure 1 It is necessary to connect the T2X to the PC before creating a configuration file Connecting the T2X for Configuration Figure 1 Connecting the T2X to the PC for Configuration POWER SOURCE 8 42Vdc AW 250 gt T2X COMMUNICATION CABLE 803 040 26 FOR NON ISOLATED 803 039 26 FOR ISOLATED CALIBRATED TO SERIAL IN PUT COM M PO RT m SIMULATOR OFPC ES 2 WIRE RTD or Q 2 WIRE RTD 3 WIRE RTD 4 WIRE RTD POTENTIOMETER OR DECADE OR DECADE OR DECADE INPUT RESISTANCE BOX RESISTANCE BOX RESISTANCE BOX Table 1 Equipment Needed for Setting Up the T2X Device Specifications Potentiometer Simulator E i r Decade B
5. additional transmitter functions Setting Engineering Unit Readout Use this setting to have the Configuration Program calculate the Centigrade or Fahrenheit tem perature for readout in the Status area of the screen Setting Input Filtering Use this radio button setting to filter out noise from the power to the transmitter Choosing Between Upscale and Downscale Drive This button configures the transmitter to drive its output either up to 24mA or down to 3 3mA when a sensor or sensor wiring failure is detected 5 Enabling Disabling Broken Wire Detection During operation the T2X sends random micro amp pulses through input wiring to check for broken wiring or a burned out sensor This can cause problems with temperature calibrators To turn this feature off set the Calibration radio button to Calibration Mode 6 Downloading your new T2X Settings To start the download process click on the Stop Start button at the bottom of the screen then on the Prog button This transfers the settings from the software to the memory of the connected transmitter The Interface Solution Experts www miinet com TEMPTATION 2000 T2X RTD Temperature Transmitter Specifications Performance InputAccuracy Performance Ripple 10mV peak to Ambient Operating amp Storage Range Platinum RTD continued peak measured across a Conditions 40 Cto 85 C 0 2 C 0 36 F 250 ohm load resistor at 40 F to 185 F N
6. esistance Boy Accurate to 0 05 of unit span Power Supply 8 42Vdc 10 Precision Load Resistor optional 2509 0 01 Multimeter Accurate to 0 025 e g Fluke Model 87 RTD Temperature vs Resistance Tables ITS68 and ITS90 or equivalent Personal Computer See Installing Software Moore Industries Successfully installed on the T2X Configuration Program hard disk of the specified PC Moore Industries Isolating PN 803 039 26 Communication Cable Installing the Software Before the transmitter can be configured the T2X PC Configuration Program must be installed on a PC with the following e 80386 based PC or faster or 100 compatible e CD Drive At least 2Mb of free Random Access Memory RAM 1Mb of free space on the PC hard disk drive Microsoft Windows 95 98 NT 4 0 2000 or XP Note More RAM and a faster processor may be required for Windows 95 98 NT 4 0 2000 and XP Consult the Windows manual for details e One 1 available serial communications port COM 1 2 or 3 set to 4800 baud no parity 8 data bits and 1 stop bit Configuring the T2X The T2X is configured using an easy to use PC Configuration Program there are no internal or external controls to adjust or settings to change All operating parameters are set using the PC program then downloaded to the nonvolatile memory of the T2X in the form of a configuration file Page 2 of the manual contains all of the inst
7. its option replace repair or refund the purchase price for any of its manufactured products found upon return to the Company transportation charges prepaid and otherwise in accordance with the return procedures established by The Company to be defective in material or workmanship This policy extends to the original Buyer only and not to Buyer s customers or the users of Buyer s products unless Buyer is an engineering contractor in which case the policy shall extend to Buyer s immediate customer only This policy shall not apply if the product has been subject to alteration misuse accident neglect or improper application installation or operation THE COMPANY SHALL IN NO EVENT BE LIABLE FOR ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES WORLDWIDE e www miinet com MOORE tei tetaysou rist FAx 818 801 2816 INDUSTRIES teis c2 8536 7200 Fax 02 9525 7296 235 781 00 B1 Belgium info mooreind be Tel 03 448 10 18 FAX 03 440 17 97 The Netherlands sales mooreind nl Tel 0 344 617971 FAX 0 344 615920 China sales mooreind sh cn Tel 86 21 62491499 FAX 86 21 62490635 United Kingdom sales mooreind com Tel 01293 514488 FAX 01293 536852 Rosemount is a registered trademark of Rosemount Inc LL moore EC Declaration of Conformity WORLDWIDE Moore Industries International Inc 16650 Schoenborn Street North Hills CA 91343 6196 U S A Date Issued 21 Oct 2013 No 100 100 245 Rev A Page 1 o
8. BY CUSTOM OR USAGE IN THE TRADE OF THE BUYER AND OF THE COMPANY AND THAT ANY PRIOR DEALINGS OF THE BUYER WITH THE COMPANY DO NOT IMPLY THAT THE COMPANY WARRANTS THE GOODS OR SERVICES IN ANY WAY ANY BUYER OF GOODS OR SERVICES FROM THE COMPANY AGREES WITH THE COMPANY THAT THE SOLE AND EXCLUSIVE REMEDIES FOR BREACH OF ANY WARRANTY CONCERNING THE GOODS OR SERVICES SHALL BE FOR THE COMPANY AT ITS OPTION TO REPAIR OR REPLACE THE GOODS OR SERVICES OR REFUND THE PURCHASE PRICE THE COMPANY SHALL IN NO EVENT BE LIABLE FOR ANY CONSEQUENTIAL OR INCIDENTAL DAMAGES EVEN IF THE COMPANY FAILS IN ANY ATTEMPT TO REM EDY DEFECTS IN THE GOODS OR SERVICES BUT INSUCH CASE THE BUYER SHALL BE ENTITLED TO NO MORE THAN A REFUND OF ALL MONIES PAID TO THE COMPANY BY THE BUYER FOR PURCHASE OF THE GOODS OR SERVICES ANY CAUSE OF ACTION FOR BREACH OF ANY WARRANTY BY THE COMPANY SHALL BE BARRED UNLESS THE COMPANY RECEIVES FROM THE BUYER A WRITTEN NOTICE OF THE ALLEGED DEFECT OR BREACH WITHIN TEN DAYS FROM THE EARLIEST DATE ON WHICH THE BUYER COULD REASONABLY HAVE DISCOVERED THE ALLEGED DEFECT OR BREACH AND NO ACTION FOR THE BREACH OF ANY WARRANTY SHALL BE COMMENCED BY THE BUYER ANY LATER THAN TWELVE MONTHS FROM THE EARLIEST DATE ON WHICH THE BUYER COULD REASONABLY HAVE DISCOVERED THE ALLEGED DEFECT OR BREACH RETURN POLICY For a period of thirty six 36 months from the date of shipment and under normal conditions of use and service Moore Industries The Company will at
9. ation To determine if a unit s area classification approvals are appropriate for a particular installation first inspect the classification labeling on the instrument and or instrument enclosure and the Control Drawing for Installation found in the User s Manual where applicable Second consult the installation criteria for the approval or electrical standard agencies governing your location to determine if the unit s approvals are suitable for the installation If the instrument s labeling matches the agency criteria and or electrical codes for the area the unit is suitable for the installation To determine if the unit s electrical and environmental specifications are appropriate for the installation consult the Specifications table in the Users Manual for that instrument If the instrument s electrical and environmental characteristics are within the expected ambient operating conditions for the installation the instrument is suitable for the installation CAUTION If for any reason you are uncertain as to whether the instrument s specifications or area classifications meet the operational or safety requirements for the installation consult Moore Industries prior to installation Installation of LH Enclosure Apparatus 1 Install the LH2 enclosure onto a surface temperature thermowell or onto a standard 2 inch pipe using the mounting hardware Remove the cap from the LH2 by rotating the cap counter clockwi
10. dicates any LH2 Enclosure with the E suffix Directive 94 9 EC ATEX Equipment and protective systems for potentially explosive atmosphere Provisions of the Directive Fulfilled by the Equipment Group II Category 2G Ex d IIC T6 Group II Category 2D Ex tD A21 IP66 T85 C Notified Body for EC Type Examination ISSeP_ Notified Body Number 0492 Zoning A Schweitzer 7340 Colfontaine Belguim EC Type Examination Certificate ISSeP 08 ATEX 033 X Technical Standards Referenced EN 60079 0 2006 Explosive atmospheres Part 0 Equipment General requirements EN 60079 1 2007 Explosive atmospheres Part 1 Equipment protection by flameproof enclosures d EN 61241 0 2006 Electrical apparatus for use in the presence of combustible dust Part 0 General requirements EN 61241 1 2004 Electrical apparatus for use in the presence of combustible dust Part 1 Protection by enclosures tD Notified Body for Quality Assurance SIRA Notified Body Number 0518 Rake Lane Eccleston Chester Cheshire CH4 9JN England On Behalf of Moore Industries International Inc declare that on the date the equipment accompanied by this declaration is placed on the market the equipment conforms with all technical and regulatory requirements of the above listed directives Signature Ce Deanna Esterwold Quality Manager fl moore INDUSTRIES User s Manual Supplement Physical Instructions for Installing an Encapsulated Hockey Puck HPP Instru
11. erent T2X The Interface Solution Experts e www miinet com 2004 Moore Industries International Inc Specifications and information subjectto change without notice Printedin U S A TEMPTATION 2000 T2X RTD Temperature Transmitter Figure 2 The Temptation 2000 PC Configuration Program provides an easy way to configure your T2X MOORE INDUSTRIES T2X HPP SETUP T2X HPP Status Input 2243 RTD Output mA Measurement ON 100 Ohms RTD Pt3850 100 Ohms i Jo is 4 Wire Inp 200 00 to 850 00 Deg C Trim 26 00 30 00 Deg C Capt 26 76 30 04 Deg C Output 4 000 to 20 000 mA Output Damping OFF Communication Power Line Frequency 60 Hz Sensor Failure Detect ON Sensor Fail Up to 24 mA Programmed 21 Jan 2004 Serial No 12345678 Firmware Version 1 1 I D Tag TT 061000 Input Type H 2 Input Full g I D Tag T o100 N O T2X HPP Not Connected Comm Port 1 Pile Es Input Range and Setup Options Input Range 240 00 to 960 00 Deg C Input Zero Degree jf Broken wire Deg F ON Deg C C OFF Filter Sensor Failure 60 Hz Down 3 3 mA 50 Hz Up 24 mA Output Of O 3 798 Qa Zero 17 397 PE 7 799 Output Full 21 398 1 Selecting Input Type Wiring etc Use the selection tools in the Input Type box to choose the sen sor type that the T2X will be reading Select the appropriate Input
12. f 2 Equipment Description RTD Temperature Transmitter Model T2X Indicates any input output power options and housing as stated in the product data sheet Directive 2004 108 EC EMC Electromagnetic Compatibility Specifications Conformed To EN 61326 1 2006 Electrical equipment for measurement control and laboratory use EMC requirements Equipment Description RTD Temperature Transmitter Model T2X 4 20mA 8 42DC HPP Indicates any input and option as stated in the product data sheet Directive 94 9 EC ATEX Equipment and protective systems for potentially explosive atmospheres Provisions of the Directive Fulfilled by the Equipment Group Il Category 3 G Ex nA IIB T6 Technical File No T2X TF001 Conformity Assessment Procedure Internal Control of Production Annex VIII Module A Technical Standards Referenced EN 60079 0 2006 Explosive atmospheres Part 0 Equipment General requirements EN 60079 15 2005 Explosive atmospheres Part 15 Equipment protection by type of protection n Ll moore EC Declaration of Conformity WORLDWIDE Moore Industries International Inc Date Issued 21 Oct 2013 No 100 100 245 Rev A 16650 Schoenborn Street North Hills CA 91343 6196 U S A Page 2 of 2 Equipment Description RTD Temperature Transmitter in the LH2 Enclosure Model T2X LH2 E Indicates any input output power and options as stated in the product data sheet In
13. he maximum allowable length of any unshielded portion of the input and or output connections is 2 inches 51mm CE Conformity Installation of any Moore Industries products that carry the CE certifi cation Commission Electrotechnique must adhere to guidelines set forth in the applicable EMC Electromagnetic Compatibility directives EN55011 EN50082 1 and EN50082 2 etc Maintaining the T2X Moore Industries suggests a quick check for terminal tightness and general unit condition every 6 8 months depending upon the severity of conditions Things such as ambient vibration corrosive atmospheres extreme heat or cold etc can play a role in shortening the service life of any piece of electronic equipment Always adhere to any site requirements for programmed maintenance Dimensions Figure 4 Dimensions for the T2X TOP VIEW 52mm 2 04 in BOTTOM VIEW Center Hole DIA 6mm 0 24 in 33mm 1 3 in Mounting Holes DIA 7mm 0 28 in WARRANTY DISCLAIMER THE COMPANY MAKES NO EXPRESS IMPLIED OR STATUTORY WARRANTIES INCLUDING ANY WARRANTY OF MERCHANTABILITY OR OF FITNESS FOR A PARTICULAR PURPOSE WITH RESPECT TO ANY GOODS OR SERVICES SOLD BY THE COMPANY THE COMPANY DISCLAIMS ALL WARRANTIES ARISING FROM ANY COURSE OF DEALING OR TRADE USAGE AND ANY BUYER OF GOODS OR SERVICES FROM THE COMPANY ACKNOWLEDGES THAT THERE ARE NO WARRANTIES IMPLIED
14. ickel RTD frequencies up to 120Hz Relative Humidity 0 16 C 0 29 F Over Voltage Protection 0 95 non condensing Copper RTD Input 4Vdc peak max Ambient Temperature Effect 1 2 C 2 16 F Output 48Vdc max 0 03 of output span C Ohms 0 4Q Digital Input Filter RFI EMI Immunity Output Accuracy User selectable 50 60Hz CE compliant when tested 0 05 of output span NOTE Overall accuracy is determined by combining input and output accuracy It includes the combined effects of linearity hysteresis repeatability and adjustment resolution It does not include ambient temperature effect Stability max span 1 year 0 12 3 years 0 21 5 years 0 27 Measurement Cycle Output updates at least 5 times per second Output Response Time 256msec typical 360msec maximum for the output to change from 10 to 90 for an input step change of 0 to 100 Power Supply and Load Effects Negligible within specified power limits Load Capability 670 ohms 24V Q Supply Voltage 8V 0 024A Burnout Protection User programmable Upscale to 24mA Downscale to 3 3mA Output Current Limiting 25mA maximum RTD Lead Wire Resistance Maximum RTD resistance 2 times the lead wire resistance must be less than 2000 ohms Recommended lt 35 ohms per wire for three wire inputs lt 5 ohms per wire for 10 ohm Cu inputs RTD amp Ohms Excitation 250A 10 Set Up Weight Input Types and Ranges
15. ironmental hazards effects the apparatus carries a NEMA Type 4X rating with an Ingress Protection Code of IP66 as per IEC 529 For applications intended in Europe and other related areas the ID Tag clearly states that the apparatus is certified by ISSeP to be Flame Proof and marked as such x II 2GD EEx d IIC T6 Tamb 20 C lt Tamb lt 60 C The temperature marking for dust atmo spheres is up to 80 C The maximum power param eters are Vmax 42 VDC Imax 110 mA and Pmax 2W Also the tag clearly shows the CE marking denoting full compliance with the relevant European Community directives applicable to the Process Instrumentation Industry For 2 wire transmitters certified and intended to be operated as either Intrinsically Safe Non Incendive Class I Div 2 or Type N the power parameters are clearly stated on both the Instrument ID Label and the Apparatus ID Tag Also the power parameters and cabling requirements are stated in the Intrinsically Safe Barrier and Field Installation Diagram that is included in the relevant User s Manuals This apparatus is designed in such a way that it a does not give rise to physical injury or other harm due to contact b does not produce excessive surface temperature infra red electromagnetic ionizing radiation and c have no non electrical dangers CAUTION Read understand and adhere to the manufacturer s installation and operating procedures Substitution of co
16. ment and LH2 Field Mount Enclosure Apparatus January 2001 The Physical Instructions Supplement provides references and additional information for safely installing and commissioning a Moore Industries Hockey Puck instrument and LH2 Field Mount Enclosure Apparatus Instrument Labeling and Identification The fully assembled apparatus consists of a Moore Industries Hockey Puck unit securely mounted in an LH2 enclosure Such an apparatus is intended for use in both indoor and outdoor Hazardous Classified Locations where a degree of protection from windblown dust and rain splashing and hose directed water and protection from the formation of ice on the enclosure is required A series of selected Moore Industries 2 Wire hockey puck style units mounted in the LH2 enclosure consult factory for a list of the certified instruments are certified as an Explosion Proof and Dust Ignition Proof appartus in accordance with Factory Mutual Research 8600 standard NEC based and as Flame Proof in accordance with the CENELEC ATEX Directive 94 9 EC IEC based For applications intended in North America and other related areas the approval classifications are stated on the externally mounted metal ID Tag to be FM approved as Explosion Proof for Class Division 1 Groups A B C and D Dust Ignition Proof for Class I II Division 1 Groups E F and G T6 60 C Maximum Operating Ambient Temperature In regards to protection from Env
17. model number to assist in verifying that the instrument received matches the instrument ordered for the installation Calibration and Configuration Describes how to accomplish instrument settings and adjustment required to set up the unit Installation and Connection Describes how to install the instrument and make electrical connections including terminal designations See the back of this Supplement for additional information on how to install the hockey puck instrument into the LH2 enclosure Maintenance Describes recommended maintenance if any required for the instrument The user should consult their own maintenance procedures for any site specific maintenance procedures such as scheduled re calibrations or other maintenance schedules that may apply to instruments such as those supplied by Moore Industries Troubleshooting Describes where applicable procedures for correcting any operational difficulties that may be encountered as a result of improper configura tion calibration or installation of the instrument Customer Support Describes the procedure and information required to efficiently receive answers to questions regarding instrument installation set up or operation The Interface Solution Experts e www miinet com 700 764 00A User s Manual Supplement Physical Instructions for Installing an Encapsulated Hockey Puck HPP Instrument and LH2 Field Mount Enclosure Apparatus Suitability for the Install
18. mponents may impair the instrument s Intrinsic Safety and or Non Incendivity Keep cover tightly closed Do not open unit when energized Do not open unit when either an explosive gas or dust atmosphere is present Cable entry temperature may exceed 70 C Cabling to be suitable Do not allow layers of dust to accumulate on the surfaces of the equipment Disconnect power before servicing Contact Information lf you have installation mainte nance periodic service warranty questions or emer gency repair requirements please contact the nearest Moore Industries sales and service office Contact information can be found on the back of this Supplement in the User s Manual for the instrument or at Moore Industries web site www miinet com User s Manual Complete information for an individual instrument model can be found in the Moore Industries Users Manual for that instrument The manual provides information for putting the instrument safely into service This where applicable includes instructions drawings and diagrams The Manual also includes appropriate Warnings Cautionary Statements and Notes User s Manual components where applicable include Introduction Brief description of the instrument and its general application and use Specifications Provides electrical and environmental conditions under which the instrument is designed to safely perform Ordering Information Provides a description of the product
19. ructions for configuring the T2X Use Figure 2 to find the portion of the screen that you have a question about The number by that area will correspond with the instructions Note The new Settings will not take effect until you have programmed the T2X with the new configuration file To program the transmitter with the T2X attached click Stop then Prog Managing Configuration Files Once all the parameters for a transmitter are set they can be saved to disk using the File menus and fields Saving a Configuration File to Disk To save a configuration file to disk click on the File button This brings up an explorer like window on the left side of the screen Enter the name of the file you wish to save in the Selected File Name box Select the location for the file to be saved and click Save Answer Yes to the dialogue box that pops up to finish saving the file Retrieving a Configuration File from Disk To retrieve a file click on the File button Use the display on the left to locate and click on the file to be retrieved Click on the Quit File button Answer Yes to the dialogue box that pops up to finish retrieving the file The file can now be downloaded to a T2X Retrieving a Configuration File from a Connected T2X To retrieve the configuration file from a connected T2X simply click Stop then Get Setup The screen will reflect any changes This file can now be saved or downloaded to a diff
20. se after unlocking by rotating the locking screw clockwise 2 Connect input and output wiring in accordance with the connection information found in the User s Manual for that instrument 3 Replace the cap to the LH2 by rotating the cap clockwise Secure lock the cap by rotating the locking screw counterclockwise 4 Connect a ground wire between the ground screw on the LH2 enclosure to an appropriate earth ground Ground Wire Recommendations The following ground wiring practices must be followed to ensure proper performance of the Moore Industries instrument in any application e Any Moore Industries product in a metal case or housing must be grounded e All input signals to and output signals from Moore Industries products should be connected using a shielded twisted pair technique Shields should be connected to an earth or safety ground at the unit itself United States info miinet com Ll M 0 0 RE Tel 818 894 71 11 FAX 81 8 891 2816 INDUSTRIES ei 02 8536 7200 Fax 02 9525 7298 2006 Moore Industries International Inc e The maximum allowable length of any unshielded portion of the input and or output connections is 2 inches 50 8mm See the User s Manual for the instrument for additional installation information Figure 1 Installation dimensions for LH2 enclosure Safety Lock 87mm ___ LH2 only 3 44 in cont NE TTT Entry Port Se a 9mm ae
21. your satisfaction it is ready for installation The T2X is available in an HPP housing style but may be enclosed in any one of several types of certified or uncertified connection heads Consult your local Moore Industries Interface Solutions Expert for information on the type of enclosure that best suits your application Figure 3 Connecting your T2X to the loop CURRENT DRIVEN INSTRUMENT POWER SOURCE 2 WIRE RTD or DECADE RESISTANCE POTENTIOMETER BOX INPUT 2 WIRE RTD OR DECADE RESISTANCE BOX RESISTANCE BOX RESISTANCE BOX 4 WIRE RTD OR DECADE 3 WIRE RTD OR DECADE Connecting the T2X in an Application Moore Industries suggests installing the T2X by first mounting the unit in its intended application then making the electrical connections to input output and power Before any installation make sure that the unit has been bench checked to ensure that it is configured and cali brated properly for its intended application Ground Wiring Recommendations The following ground wiring practices must be followed to ensure proper performance of the T2X in any application e Any Moore Industries product in a metal case or housing must be grounded e All input signals to and output signals from Moore Indus tries products should be connected using a shielded twisted pair technique Shields should be connected to an earth or safety ground at the unit itself e T