Home

Switched Rack PDU Installation and Quick Start

image

Contents

1. ArCE www apc com Switched Rack Power Distribution Unit AP7902 AP7911 Installation and Quick Start Contents Product Description and Inventory ooooooooooo APTDOZ sa a a a ea ew teste 1 PARTON AE A LAS A A IA at ee ee 1 Additional documentation ooo oooooooo 2 Inventor aio tao e aia ae eee le 2 Receiving inspection 1 0 ce mc 2 Please recycle ooo 2 InfraStruXure certified o o o o oooooooooooooooo s 2 How to Install the Rack POU 1 1 ee Installation guidelines o ooooooooooooooo s 3 Attach the cord retention tray lt oooooooooooo oo 3 Additional cord retention tray optional 3 Attach cords to the tray o oo ooo ooo o 4 Mounting options 2 ce ee 4 Opera Maira we ewe de Sa a e ee Se ee a Display interface 2 eee 6 QUICK Configuration lt lt AAA AAA OVER VIG Wi O A Ned 7 TCP IP configuration methods o oooooooomo ooo 7 APC Management Card Wizard oooooo oo ooo 8 BOOTP amp DHCP configuration lt lt lt 8 Local access to the control console o oo ooo 11 Remote access to the control console oo ooo 11 Control console ooo 12 How to Access a Configured Rack PDU OVervieW 2012 ee hon eA oath eee dye aie eee T 13 Webinterface cic dah Se eld SOE Pee Pe ee Oa 13 TeInet SSH iii eon eee eae we a 14 SNMP joo eee A a a a Whe A ala ele Whe
2. Client Identifier by default the Rack PDU s MAC address User Class Identifier by default the identification of the Rack PDU s application firmware 2 A properly configured DHCP server responds with a DHCP offer that includes all of the settings that the Rack PDU needs for network communication The DHCP offer also includes the Vendor Specific Information option DHCP option 43 By default the Rack PDU ignores DHCP offers that do not encapsulate the APC cookie in the Vendor Specific Information option using the following hexidecimal format Option 43 01 04 31 41 50 43 where The first byte 01 is the code The second byte 04 is the length The remaining bytes 31 41 50 43 are the APC cookie See your DHCP server documentation to add code to QS the Vendor Specific Information option See also To disable the APC cookie requirement you can use a local computer See Local access to the control console on page 11 To change the control console s DHCP Cookie Is setting an Advanced option in the TCP IP menu use Telnet or another remote accessing method See Remote access to the control console on page 11 10 Switched Rack PDU Installation and Quick Start Quick Configuration Local access to the You can use a local computer to connect to the Rack PDU to access the control console control console 1 Select a serial port at the local computer and disable any service which uses that
3. See the User s Guide to use FTP or SCP See also to retrieve log files from the Network Management Card al Switched Rack PDU Installation and Quick Start 15 How to Recover From a Lost Password You can use a local computer a computer that connects to the Rack PDU or other device through the serial port to access the control console 1 Select a serial port at the local computer and disable any service that uses that port Connect the APC smart signaling cable 940 0144 to the selected port on the computer and to the serial port at the Rack PDU Run a terminal program such as HyperTerminal and configure the selected port as follows 9600 bps 8 data bits no parity 1 stop bit no flow control Press ENTER repeatedly if necessary to display the User Name prompt If you are able to display the User Name prompt verify the following The serial port is not in use by another application The terminal settings are correct as specified in step 3 The correct cable is being used as specified in step 2 Press the Reset button The Status LED will flash between red or orange and green Press the Reset button a second time immediately while the LED is flashing to reset the user name and password to their defaults temporarily Press ENTER as many times as necessary to redisplay the User Name prompt then use the default ape for the user name and password If you take
4. 34 ea AUN 11200
5. light Note eA See Watchdog Features in the Introduction of the lt A User s Guide for more information about the watchdog See also role of the default gateway TCP IP configuration Use one of the following methods to define the TCP IP settings methods e APC Management Card Wizard See APC Management Card Wizard on page 8 BOOTP or DHCP server See BOOTP amp DHCP configuration on page 8 e Local computer See Local access to the control console on page 11 e Networked computer See Remote access to the control console on page 11 Switched Rack PDU Installation and Quick Start 7 Quick Configuration APC Management Card You can use the APC Management Card Wizard at a Windows 98 Wizard Windows NT 4 0 Windows 2000 or Windows XP computer to configure a Rack PDU 1 Insert the APC Switched Rack PDU Utility CD into a computer on your network 2 Launch the Wizard when prompted or if prompted to restart the computer access the Wizard from the Start menu after the computer has restarted 3 Wait for the Wizard to discover the unconfigured Rack PDU then follow the on screen instructions If you leave the Start a Web browser when finished option enabled you can use ape for both the user name and password to access the Rack PDU through your Note browser BOOTP amp DHCP The Boot Mode setting a TCP IP option in the Rack PDU s Network configuration menu identifies how TC
6. port 2 Use the configuration cable 940 0144 to connect the selected port to the serial port on the front panel of the Rack PDU 3 Run a terminal program such as HyperTerminal and configure the selected port for 9600 bps 8 data bits no parity 1 stop bit and no flow control and save the changes 4 Press ENTER to display the User Name prompt 5 Use ape for the user name and password 6 See Control console on page 12 to finish the configuration Remote access to the From any computer on the same subnet as the Rack PDU you can use control console ARP and Ping to assign an IP address to the Rack PDU and then use Telnet to access that Rack PDU s control console and configure the needed TCP IP settings use Telnet without first using ARP and Ping to access that O After the Rack PDU has its IP address configured you can Rack PDU Note 1 Use ARP to define an IP address for the Rack PDU and use the Rack PDU s MAC address in the ARP command For example to define an IP address of 156 205 14 141 for the Rack PDU that has a MAC address of 00 c0 b7 63 9f 67 use one of the following commands Windows command format arp s 156 205 14 141 00 c0 b7 63 9f 67 LINUX command format arp 156 205 14 141 00 c0 b7 63 9f 67 The MAC address is on the bottom of the Rack PDU and on the Quality Assurance slip included in the package Note 2 Use Ping with a size of 113 bytes to assign the IP address d
7. 14 FREPSS GP a a guns fa O O fo eee ca cep fas 15 How to Recover From a Lost Password Switched Rack PDU Installation and Quick Start How to Download Firmware Updates Specifications oe ai a e A a APTIOZSAPT O Too a a a ws ee 18 Warranty and Service ooooooocoomcocoononnmmmoo Limited Warranty aii a Pe ee See aa 19 Warranty limitations 2 1 aana 19 Obtaining service 000 e eee eee ee ee eee 19 Life Support PONCy ccoo eos e heen General policy iio 2 eee a a a e 20 Examples of life support devices o o ooooooo oo 20 Switched Rack PDU Installation and Quick Start Product Description and Inventory AP7902 and AP7911 are Switched Rack Power Distribution Units Rack PDUs that distribute power to devices in the rack The user can turn on turn off or recycle power back to the individually controlled outlets The Rack PDUs also have a sensor that measures the current being used by the Rack PDUs and their attached devices The Rack PDUs can be monitored through Web Telnet SNMP or InfraStruXure Manager interfaces AP7902 Bank 1 Eight NEMA 5 20 outlets 20A circuit breaker for Bank 1 20A circuit breaker for Bank 2 Display interface Bank 2 Eight NEMA 5 20 outlets NEMA L5 30 plug with a 12 foot power cord O 0 AP7911 DR 00 E ds E o Bank 1 Eight IEC 320 C13 outlets 15 A circuit breaker for Bank 1 15 A circui
8. P IP settings will be defined The possible settings are Manual DHCP only BOOTP only and DHCP amp BOOTP the default setting The DHCP amp BOOTP setting assumes that a properly configured DHCP or BOOTP server is available to provide TCP IP settings to the Rack PDU If these servers are O unavailable see APC Management Card Wizard on this page Local access to the control console on page 11 or Remote access to the control console on page 11 to configure the TCP IP settings Note With Boot Mode set to DHCP amp BOOTP the Rack PDU attempts to discover a properly configured server It first searches for a BOOTP server and then a DHCP server It repeats this pattern until it discovers a BOOTP or DHCP server For more information see BOOTP on page 9 or DHCP on page 10 8 Switched Rack PDU Installation and Quick Start Quick Configuration BOOTP You can use an RFC951 compliant BOOTP server to configure the TCP IP settings for the Rack PDU If the BOOTP server is properly configured the Rack PDU s default setting DHCP amp BOOTP for BOOT Mode causes it to discover the BOOTP server If a BOOTP server is unavailable see APC Management Card Wizard on page 8 Local access to the control console on page 11 or Remote access to the control console on page 11 to configure TCP IP settings 1 Enter the Rack PDU s MAC and IP addresses the subnet mask and default gatew
9. U Installation and Quick Start 3 How to Install the Rack PDU Attach cords to the tray Attach a cord to the tray by looping the cord and securing it to the tray using a wire tie provided Cords from both banks of outlets may be secured to the bottom tray or you may attach an additional tray shown on the preceding page to secure cords from the top bank of outlets Make sure the cords that are attached to the upper tray do not interfere with the operation of the circuit breakers Each cord must be secured to the tray so that you can unplug 1t from the Rack PDU without removing the wire tie Note Mounting options You can install the Rack PDU in one of two ways flush with the rack or recessed to allow the use of the cord retention bracket To mount the Rack Rack PDU horizontally in a NetShelter or any other standard EIA 310 rack or enclosure 1 Attach the mounting brackets to the Rack PDU using the flat head screws provided Some enclosures may require you to recess the Rack PDU so that the back doors of the enclosure will close Note when other devices are plugged in to the Rack PDU For placement flush to rack use four flat head screws provided for each bracket 4 Switched Rack PDU Installation and Quick Start How to Install the Rack PDU For a recessed placement use four flat head screws provided through the last four holes of each bracket 2 Insert caged nuts provided with the rack on the verti
10. ay settings and an optional bootup file name in the BOOTPTAB file of the BOOTP server O The MAC address is on the bottom of the Rack PDU and on the Quality Assurance slip included in the package Note 2 When the Rack PDU reboots the BOOTP server provides it with the TCP IP settings If you specified a bootup file name the Rack PDU attempts to transfer that file from the BOOTP server using TFTP or FTP The Rack PDU assumes all settings specified in the bootup file If you did not specify a bootup file name the Rack PDU can be configured remotely by using Telnet or by using the Web interface user name and password are both apc by default See Remote access to the control console on page 11 for configuration instructions You must use the APC Management Card Wizard to create the bootup file To create a bootup file see the See also BOOTP section in the Addendum i Switched Rack PDU Installation and Quick Start 9 Quick Configuration DHCP You can use a RFC2131 RFC2132 compliant DHCP server to configure the TCP IP settings for the Rack PDU E This section summarizes the Rack PDU communication QO with a DHCP server For more detail about how a DHCP server is used to configure the network settings for the Rack PDU see DHCP Configuration in the User s Guide See also 1 The Rack PDU sends a DHCP request that uses the following to identify itself Vendor Class Identifier APC by default
11. cal mounting rails above a number at the start of two U spaces in your enclosure and below a number at the lower end of those two U spaces E L 24 b LJ E 3 Align the mounting holes on the brackets with the caged nuts you installed in step 2 and insert four mounting screws provided with the rack to secure the brackets to the enclosure Switched Rack PDU Installation and Quick Start 5 Operation Display interface 0 2 OK Se a E TOTAL Warnin Link Rx Tx gt O A E Gea Ep 10 100 gt 8 Status 3 3 0 30 i i APC www apc com J L Q Amp Switched Rack PDU Reset F Serial Port O Line Indicator LED Indicates normal green warning yellow and alarm red conditions for bank 1 B1 bank 2 B2 or the total of the two banks both B1 and B2 illuminated O Control button e Press and hold for five seconds to view the orientation hold for an additional five seconds to change the orientation e Press to change from B1 to B2 B2 to TOTAL or TOTAL to B1 Ethernet port Connects the Rack PDU to your network using a CATS network cable Status LED Indicates the status of the Ethernet LAN connection and the state of the Rack PDU e Off The Rack PDU has no power e Solid green The Rack PDU has valid TCP IP settings e Flashing green Th
12. client program installed on your computer EA See the User s Guide for more information on configuring QS and using SSH See also After you add the PowerNet MIB to a standard SNMP MIB browser you can use that browser for SNMP access to the Rack PDU The default read community name is public the default read write community name is private If you enable SSL and SSH disable SNMP Allowing SNMP access compromises the high security environment of SSL and SSH Administrators can disable SNMP using the Note SNMP option of the Network menu Switched Rack PDU Installation and Quick Start FTP SCP How to Access a Configured Rack PDU You can use FTP enabled by default or Secure CoPy SCP to transfer new firmware to the Rack PDU or to access a copy of the Rack PDU s event logs SCP provides the higher security of encrypted data transmission and is automatically enabled when you enable SSH If you enable SSL and SSH disable FTP Allowing file O transfers using FTP compromises the high security environment of SSL and SSH Administrators can disable Note FTP using the FTP Server option of the Network menu To access the Rack PDU through FTP or SCP the default user name and password are apc and ape for an Administrator or device and ape for a Device Manager In the command line use the IP address of the unit See the Network Management Card Addendum to use FTP or SCP to transfer firmware files to the Network Management Card
13. dispose of them appropriately This product is certified for use in InfraStruXure systems The Configuration section beginning on page 7 does not apply to Rack PDUs that are part of InfraStruXure systems managed by an InfraStruXure Manager Switched Rack PDU Installation and Quick Start How to Install the Rack PDU For a Rack PDU installed in an enclosed communications rack the recommended maximum ambient temperature is 45 C 113 E Install the Rack PDU so that it does not reduce the air flow required for safe operation of the equipment Install the Rack PDU so that there is an even mechanical load Follow the nameplate ratings when connecting equipment to the Installation guidelines supply circuit Avoid overloading the circuits which could affect over circuit protection and supply wiring Maintain reliable earthing of the Rack PDU especially supply connections that do not directly connect to the branch circuit Install the Rack PDU so that the power plug is accessible to be disconnected for service Attach the cord Attach the cord retention tray to the Rack PDU using four flat head retention tray screws provided per tray Mount an additional cord retention tray to secure cords from the top bank of outlets Purchase additional tray kits ore from APC AP9569 Additional cord Attach a second cord retention tray to the PDU with the cord retainers retention tray optional facing down Switched Rack PD
14. e Rack PDU does not have valid TCP IP settings e Solid orange A hardware failure has been detected in the Rack PDU Contact Customer Support at a phone number on the back cover of this manual e Flashing orange The Rack PDU is making BOOTP requests Link LED Indicates whether there is activity on the network O Serial port Access internal menus by connecting this port RJ 11 modular port to a serial port on your computer using the supplied serial cable 940 0144 Digital display Displays the current used by the Rack PDU and attached devices Shows the aggregate current for the Rack PDU for bank 1 B1 bank 2 B2 or the total current of both bank 1 and bank 2 TOTAL O Reset switch Resets the Rack PDU without affecting the outlet status 6 Switched Rack PDU Installation and Quick Start Quick Configuration Disregard the procedures in this section if you have APC A InfraStruXure Manager as part of your system See the InfraStruXure Manager s documentation for more Warning information Overview You must configure the following TCP IP settings before the Rack PDU can operate on a network IP address of the Rack PDU e Subnet mask e Default gateway If a default gateway is unavailable use the IP address of a computer that is located on the same subnet as the Rack PDU and that is usually running The Rack PDU uses the default gateway to test the network when traffic is very
15. ecific legal rights and you may also have other rights which vary according to jurisdiction To obtain support for problems with your Rack PDU 1 Note the serial number and date of purchase The serial number is located on the safety label on the back of the Rack PDU 2 Contact Customer Support at a phone number located on the back cover A technician will try to help you solve the problem by phone 3 If you must return the product the technician will give you a return material authorization RMA number If the warranty expired you will be charged for repair or replacement 4 Pack the unit carefully The warranty does not cover damage sustained in transit Enclose a letter with your name address RMA number and daytime phone number a copy of the sales receipt and a check as payment if applicable 5 Mark the RMA number clearly on the outside of the shipping carton 6 Ship by insured prepaid carrier to the address provided by the Customer Support technician Switched Rack PDU Installation and Quick Start 19 Life Support Policy General policy Examples of life support devices 20 American Power Conversion APC does not recommend the use of any of its products in the following situations e In life support applications where failure or malfunction of the APC product can be reasonably expected to cause failure of the life support device or to affect significantly its safety or effectiveness e In direct pat
16. efined by the ARP command For example Windows command format ping 156 205 14 141 1 113 LINUX command format ping 156 205 14 141 s 113 Switched Rack PDU Installation and Quick Start 11 Quick Configuration 3 Use Telnet to access the Rack PDU at its newly assigned IP address For example telnet 156 205 14 141 4 Use apc for both user name and password 5 See Control console on this page to finish the configuration Control console After you log on at the control console as described in Local access to the control console on page 11 or Remote access to the control console on page 11 1 Choose Network from the Control Console menu 2 Choose TCP IP from the Network menu 3 If you are not using a BOOTP or DHCP server to configure the TCP IP settings select the Boot Mode menu Select Manual boot mode and then press ESC to return to the TCP IP menu Changes will take effect when you log out 4 Set the System IP Subnet Mask and Default Gateway address values 5 Press CTRL C to exit to the Control Console menu 6 Log out option 4 in the Control Console menu If you disconnected a cable during the procedure described in Local access to the control console on page 11 reconnect that cable and restart the associated Note service 12 Switched Rack PDU Installation and Quick Start How to Access a Configured Rack PDU Overview Web interface After the Rack PDU is running o
17. ety verification UL cUL 60950 EMC verification FCC Part 15 Class A ICES 003 Class A Switched Rack PDU Installation and Quick Start Warranty and Service Limited warranty Warranty limitations Obtaining service APC warrants the Rack PDU to be free from defects in materials and workmanship for a period of two years from the date of purchase Its obligation under this warranty is limited to repairing or replacing at its own sole option any such defective products This warranty does not apply to equipment that has been damaged by accident negligence or misapplication or has been altered or modified in any way This warranty applies only to the original purchaser Except as provided herein APC makes no warranties express or implied including warranties of merchantability and fitness for a particular purpose Some jurisdictions do not permit limitation or exclusion of implied warranties therefore the aforesaid limitation s or exclusion s may not apply to the purchaser Except as provided above in no event will APC be liable for direct indirect special incidental or consequential damages arising out of the use of this product even if advised of the possibility of such damage Specifically APC is not liable for any costs such as lost profits or revenue loss of equipment loss of use of equipment loss of software loss of data costs of substitutes claims by third parties or otherwise This warranty gives you sp
18. ient care APC will not knowingly sell its products for use in such applications unless it receives in writing assurances satisfactory to APC that a the risks of injury or damage have been minimized b the customer assumes all such risks and c the liability of American Power Conversion is adequately protected under the circumstances The term life support device includes but is not limited to neonatal oxygen analyzers nerve stimulators whether used for anesthesia pain relief or other purposes autotransfusion devices blood pumps defibrillators arrhythmia detectors and alarms pacemakers hemodialysis systems peritoneal dialysis systems neonatal ventilator incubators ventilators for adults and infants anesthesia ventilators infusion pumps and any other devices designated as critical by the U S FDA Hospital grade wiring devices and leakage current protection may be ordered as options on many APC UPS systems APC does not claim that units with these modifications are certified or listed as hospital grade by APC or any other organization Therefore these units do not meet the requirements for use in direct patient care Switched Rack PDU Installation and Quick Start Radio Frequency Interference USA FCC Canada ICES Japan VCCI Changes or modifications to this unit not expressly approved by the party A responsible for compliance could void the user s authority to operate this equipment Warni
19. longer than 30 seconds to log on after the User Name prompt is redisplayed you must repeat step 5 and log on again From the Control Console menu select System then User Manager Select Administrator and change the User Name and Password settings both of which are now defined as apc Press CTRL C log off reconnect any serial cable you disconnected and restart any service you disabled 16 Switched Rack PDU Installation and Quick Start How to Download Firmware Updates SLA For a complete description on how to download a firmware upgrade for your Rack PDU see the Addendum on the See also Provided APC Switched Rack PDU Utility CD You can use a local computer that connects to the Rack PDU through the serial port on the front of the unit 1 Select a serial port at the local computer and disable any service that uses that port Use the configuration cable 940 0144 to connect the selected port to the RJ 12 serial port on the front panel of the Rack PDU Run a terminal program such as HyperTerminal and configure the selected port for 9600 bps 8 data bits no parity 1 stop bit and no flow control Save the changes 4 Press ENTER twice to display the User Name prompt Enter your user name and password both ape for administrators only and press ENTER From the Control Console menu select System then Tools then XMODEM The system will prompt you with Perform transfer
20. n your network you can use the interfaces summarized here to access the unit For more information on the interfaces see the User s Guide located on the supplied CD and on the APC Web See also Site Www apc com LA As your browser you can use Microsoft Internet Explorer 5 0 and higher or Netscape 4 0 8 and higher except Netscape 6 x to access the Management Card through its Web interface Other commonly available browsers also may work but have not been fully tested by APC To use the Web browser to configure Rack PDU options or to view the event log you can use either of the following The HTTP protocol enabled by default which provides authentication by user name and password but no encryption e The HTTPS protocol which provides extra security through Secure Socket Layer SSL and encrypts user names passwords and data being transmitted It also provides authentication of Network Management Cards by means of digital certificates To access the Web interface and configure the security of your device on the network 1 Address the Rack PDU by its IP address or DNS name if configured 2 Enter the user name and password by default ape and ape for an Administrator or device and apc for a Device Manager 3 Select and configure the type of security you want This option is available only for Admininistrators See the chapter entitled Security in the User s Guide eA for information on choosing and se
21. ng This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with this user manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference The user will bear sole responsibility for correcting such interference This Class A digital apparatus complies with Canadian ICES 003 Cet appareil num rique de la classe A est conforme la norme NMB 003 du Canada This is a Class A product based on the standard of the Voluntary Control Council for Interference by Information Technology Equipment VCCI If this equipment is used in a domestic environment radio disturbance may occur in which case the user may be required to take corrective actions TOREJ RU AE H ERR Az VCCI D TZ FR A TAMER CT CORB ARE Ra CAT Ob SS ESC DADA AAA ARAS OL IRENA ESE www apc com APC Worldwide Customer Support Customer support for this or any other APC product is available at no charge in any of the following ways e Visit the APC Web site to find answers to frequently asked ques
22. t breaker for Bank 2 Display interface Bank 2 Eight IEC 320 C13 outlets NEMA L6 30 plug with a 12 foot power cord 0000006 Switched Rack PDU Installation and Quick Start Product Description and Inventory Additional documentation Inventory Receiving inspection Please recycle InfraStruXure certified The Rack PDU User s Guide and the Rack PDU Addendum are available on the supplied CD and on the APC Web site www apc com The User s Guide doc eng usrguide pdf contains additional information about the following topics related to the Rack PDU e Management interfaces e User accounts e Customizing setup e Security The Addendum doc eng addendum pdf contains additional information about the following topics e The Management Card Wizard e Configuration utilities e File transfers The Rack PDU is shipped with the following items Quantity Item 1 Configuration cable 940 0144 1 Cord retention tray with 4 flat head screws and 16 wire ties 2 Mounting brackets with 8 flat head screws 4 Rubber feet 1 APC Switched Rack PDU Utility CD 1 Warranty registration card Inspect the package and contents for shipping damage and make sure that all parts were sent Report any damage immediately to the shipping agent and report missing contents damage or other problems immediately to APC or your APC reseller The shipping materials are recyclable Please save them for later use or
23. tions FAQs to access documents in the APC Knowledge Base and to submit customer support requests www apc com Corporate Headquarters Connect to localized APC Web sites for specific countries each of which provides customer support information www apc com support Global support with FAQs knowledge base and e support e Contact an APC Customer Support center by telephone or e mail Regional centers Direct InfraStruXure Customer Support 1 877 537 0607 toll free APC headquarters U S Canada 1 800 800 4272 toll free Latin America 1 401 789 5735 USA Europe Middle East Africa 353 91 702000 Ireland Japan 0 35434 2021 Australia New Zealand South Pacific 61 2 9955 9366 Australia Local country specific centers go to www apc com support contact for contact information Contact the APC representative or other distributor from whom you purchased your APC product for information on how to obtain local customer support Entire contents copyright 2003 American Power Conversion All rights reserved Reproduction in whole or in part without permission is prohibited APC the APC logo InfraStruXure and NetShelter are trademarks of American Power Conversion Corporation and may be registered in some jurisdictions All other trademarks product names and corporate names are the property of their respective owners and are used for informational purposes only
24. tting up your network QZ security Use the Web SSL TLS option of the Network See also menu to enable or disable the HTTP or HTTPS protocols Switched Rack PDU Installation and Quick Start 13 How to Access a Configured Rack PDU Telnet SSH SNMP You can access the control console through Telnet or Secure SHell SSH depending on which is enabled An Administrator can enable these access methods through the Telnet SSH option of the Network menu By default Telnet is enabled Enabling SSH automatically disables Telnet Telnet for basic access Telnet provides the basic security of authentication by user name and password but not the high security benefits of encryption To use Telnet to access a Rack PDU s control console from any computer on the same subnet 1 Ata command prompt use the following command line and press ENTER telnet address As address use the Rack PDU s IP address or DNS name if configured 2 Enter the user name and password by default ape and ape for an Administrator or device and ape for a Device Manager SSH for high security access If you use the high security of SSL for the Web interface use Secure SHell SSH for access to the control console SSH encrypts user names passwords and transmitted data The interface user accounts and user access rights are the same whether you access the control console through SSH or Telnet but to use SSH you must first configure SSH and have an SSH
25. with XMODEM CRC Type Yes and press ENTER The system will then prompt you to choose a transfer rate and to change your terminal settings to match the transfer rate Press ENTER to set the Rack PDU to accept the download In the terminal program send the file using the XMODEM protocol Upon completion of the transfer the console will prompt you to restore the baud rate to normal A Do not interrupt the download Caution The Rack PDU will reboot when the download is complete O Upgrading the firmware will not interfere with the operation of the outlets Note Switched Rack PDU Installation and Quick Start 17 Specifications AP7902 AP791 1 Electrical AP7902 AP7911 Nominal input voltage 120 V 208 V Acceptable input voltage 10 Nominal input voltage Maximum input current 24A Input frequency 47 63 Hz Cord length 12 ft Input connectors NEMA L5 30 plug NEMA L6 30 plug Sixteen NEMA 5 20 Sixteen IEC 320 C13 Output connectors outlets outlets Overload protection 20A 15A Physical Size H x W x D 3 5x17 5x4 5 in 88 9 x444 5x 114 3 mm Weight 9 9 lb 4 49 kg Shipping weight 14 4 lb 6 53 kg Environmental Elevation above MSL Operating 0 15 000 ft 0 4500 m Storage 0 50 000 ft 0 15 000 m Temperature Operating 5 to 45 C 23 to 115 F Storage 25 to 65 C 13 to 149 E Humidity Operating 5 95 RH Non condensing Storage 5 95 RH Non condensing Compliance Saf

Download Pdf Manuals

image

Related Search

Related Contents

Deutsch English Español Italiano  User Manual in PDF - All Spectrum Electronics  Description et fonctionnement  Avaya IVR - Business Communications Manager Upgrade Guide  Proctor-Silex Coffeemaker 48575 User's Manual  WD My Cloud Expert/Business Storage Drive User Manual  SoftBank 101DL 取扱説明書  

Copyright © All rights reserved.
Failed to retrieve file