Home

CANoe/CANalyzer MSI Setup

image

Contents

1. tion Manual istra 1m1S Adm 4 ion 1 Vers sh li Eng vector Imprint Vector Informatik GmbH Ingersheimer Str 24 D 70499 Stuttgart The information and data given in this user manual can be changed without prior notice No part of this manual may be reproduced in any form or by any means without the written permission of the publisher regardless of which method or which instruments electronic or mechanical are used All technical information drafts etc are liable to law of copyright protection Copyright 2010 Vector Informat k GmbH All rights reserved Administration Manual CANoe CANalyzer MSI Setup Table of contents 1 1 1 2 2 1 2 2 2 3 2 4 2 5 2 6 2 7 2 8 2 9 2 10 2 11 2 12 2 13 2 14 3 1 3 2 3 3 4 1 4 2 4 3 4 4 Introduction MSI Setup at a Glance About this User Manual 1 2 1 Access Helps and Conventions 1 2 2 Certification 1 2 3 Warranty 1 2 4 Support 1 2 5 Registered Trademarks Setup Prerequisites Overview Windows Installer 3 1 Visual Basic Runtime 6 0 SP3 NET Framework 3 5 SP1 Windows Updates for NET Framework 3 5 SP1 Visual J 2 0 Redistributables CANoe CANalyzer Redistributables CANoe CANalyzer Redistributables for 64 Bit Operating Systems MSXML 6 0 Parser and SDK Microsoft Visual C 2005 SP1 Redistributable Common Controls Microsoft Visual C 2008 Redistributable Microsoft XNA 2 0 Redistributables Microsoft DirectX February 20
2. gt have to be added and or modified in the Property table of the MST when using your own transform files for deployment For an example please refer to chapter 4 1 Silent Installation Example Info Property names are case sensitive Property VAPPLICATION DATA FOLDER VUSER_DATA FOLDER VAPPLICATION_AND DATA_ROOT Meaning Absolute path where the application data is stored e g INI files Absolute path where the user data is stored e g demo configurations If neither VAPPLICATION DATA_ FOLDER nor VUSER_DATA FOLDER is set you can set both paths to predefined values using the following values for VAPPLICATION AND_ DATA_ROOT 1 Application and user data is stored in the current user s profile 2 Application data and user data is stored in all users profile recommended 3 Application data and user data is stored in the CANoe CANalyzer program folder not recommended This value is not supported on Windows Vista and later Version 1 4 Default Value No default value see also VAPPLICATION AND DATA ROOT No default value see also VAPPLICATION AND_ DATA ROOT The default value is set to 2 Thus the default user data target is example AllUsersProfile Doc uments Vector CANoe Deb or sAllUsersProfile Doc uments Vector CANalyzer 7 5 The default application data target is example AllUsersProfile App licationData Vector CANoe
3. gt Atthe beginning of each chapter you will find a summary of the contents In the header you can see in which chapter and paragraph you are situated In the footer you can see to which version the user manual replies At the end of the user manual you will find an index with whose help you will quickly find information Conventions In the two following charts you will find the conventions used in the user manual regarding utilized spellings and symbols Style bold CANoe Source code Hyperlink lt STRG gt lt S gt Symbol A O Vector Informatik GmbH Utilization Blocks surface elements window and dialog names of the software Accentuation of warnings and advices OK Push buttons in brackets File Save Notation for menus and menu entries Legally protected proper names and side notes File name and source code Hyperlinks and references Notation for shortcuts Utilization Here you can obtain supplemental information This symbol calls your attention to warnings Here you can find additional information Here is an example that has been prepared for you Step by step instructions provide assistance at these points Instructions on editing files are found at these points This symbol warns you not to edit the specified file Version 1 4 5 Introduction Administration Manual CANoe CANalyzer MSI Setup 1 2 2 Certification Certified Quality Management System 1 2 3 Warranty Rest
4. It is assumed that this prerequisite is met 2 3 Visual Basic Runtime 6 0 SP3 Prerequisites Installation check Installation The Visual Basic 6 0 SP3 Runtime is needed You can find a setup program called VBRun60sp3 exe To check if the correct Visual Basic Runtime is installed check if a file called msvbvm60 d11 with at least version 6 0 84 95 is installed on the target machine under 3SYSTEMROOT system32 To install the Visual Basic Runtime silently append Q to the setup program vbrun60sp3 exe 0 2 4 NET Framework 3 5 SP1 Prerequisites Installation check The Net Framework 3 5 SP1 needs to be installed in order to use CANoe CANalyzer To check if the Net Framework is installed you can check if the following registry key is present HKEY LOCAL MACHINE SOFTWARE Microsoft NET Framework Setup NDP v3 5 If this registry key exists the Net Framework 3 5 is installed this could also be 3 5 without any Service Pack Please note that this registry key also exists when a higher version of the Net Framework is installed Additionally the following value must appear below this key and its value must be 1 or greater to be sure that SP 1 is installed SP 1 Version 1 4 Vector Informatik GmbH Administration Manual CANoe CANalyzer MSI Setup Setup Prerequisites Installation 2 5 Windows Prerequisites Installation check and Installation To install the NET Framework 3 5 SP1 si
5. application components and how embedded transforms can be used to setup CANoe and CANalyzer alongside on the same machine chapter 3 This document applies to CANoe CANalyzer version 7 5 and up For an updated version of this document please always check the documentation that came with your product before packaging the application as some items mentioned here are version dependent e g updated installation prerequisites When silently installing CANoe CANalyzer using MST transforms make sure that all files and folders from the installation media s CANoe or CANalyzer folder are present in the folder from where the CANoe_CANalyzer msi will be called by your setup scripts typically a network share or a local temporary folder on the target system In case you have received personalized installer media from Vector i e you have not received separate installation key information you may omit setting the public properties gt VSETUPKEY CUSTOMER gt VSETUPKEY SERIALNUMBER and gt VSETUPKEY LICENSEKEY as the installation information product variant bus options serial number etc is already contained in the installer files Version 1 4 Vector Informatik GmbH Administration Manual CANoe CANalyzer MSI Setup Introduction 1 2 About this User Manual 1 2 1 Access Helps and Conventions To find information The user manual provides you the following access helps quickly VV V
6. installed check if the software with the following product code is installed A43BF6A5 D5F0 4AAA BF41 65995063EC44 To check if the Microsoft MSXML 6 0 SP1 Parser and SDK Security Update KB is installed check if the software with the following product code is installed 0A869A65 8C94 4F7C A5C7 972D3C8CED9E Installation To install the MSXML 6 0 SP1 Parser and SDK Security Update silently use the following command msxml6 KB933579 enu x86 exe q 10 Version 1 4 Vector Informatik GmbH Administration Manual CANoe CANalyzer MSI Setup Setup Prerequisites 2 10 Microsoft Visual C 2005 SP1 Redistributable Installation check To verify that the Microsoft Visual C 2005 SP1 Redistributables are installed check if the software with the following product code is installed 7299052b 02a4 4627 81 2 1818da5d550d Installation To install the Microsoft Visual C 2005 SP1 Redistributables silently use the following command vcredist_x86 exe Q C msiexec I vcredist msi q 2 11 Common Controls Installation check To check if a proper version of the common controls is installed check if the version of file COMCTL32 DLL in the system32 directory is at least 5 80 0 0 Installation To install the common controls silently use the following command 50Comupd exe r n 2 12 Microsoft Visual C 2008 Redistributable CANoe CANalyzer Effective with CANoe CANalyzer v7 2 SP1 you also have to have t
7. 10 Redistributables Settings Customizable Properties Selectable Applications Transforms Further Installations Silent Installation Example Service Pack Installation 4 2 1 Prerequisites 4 2 2 Silent Update Update of 7 5 Pre Release Hardware Installation Appendix A Address Table Vector Informatik GmbH Version 1 4 Table of contents OUI KR O o oo 0 0 N mek ek ks ek ek Gee VI N a a 2 an sp _ N o NNN NNN N N N N N oo Administration Manual CANoe CANalyzer MSI Setup 1 Introduction In this chapter you find the following information 1 1 MSI Setup at a Glance 1 2 About this User Manual Access Helps and Conventions Certification Warranty Support Registered Trademarks Vector Informatik GmbH Version 1 4 Introduction page 4 page 5 Introduction Administration Manual CANoe CANalyzer MSI Setup 1 1 MSI Setup at a Glance Installation guide Important note for silent installation This document provides an installation guide for IT departments who want to install Vector CANoe CANalyzer silently on target machines using software deployment systems It is assumed that the reader is familiar with the Windows Installer technology and the software deployment system used After depicting the necessary Setup Prerequisites chapter 2 this document explains how the public properties of the installer can be configured in order to install the required
8. 7 5 or AllUsersProfile App licationData Vector CANalyzer 7 5 Vector Informatik GmbH Administration Manual CANoe CANalyzer MSI Setup Settings Property Meaning Default Value see below VPROGRAM LANGUAGE Language to use at 01 program start Possible values are 01 English 49 German VSTART_MENU_FOLDER Program menu entry that Vector CANoe 7 5 will be used for program or shortcuts Vector CANalyzer 7 5 INSTALLDIR Absolute path where the ProgramFilesFolder application should be Vector CANoe 7 5 installed to or ProgramFilesFolder Vector CANalyzer 7 5 VSETUPKEY CUSTOMER Name of customer that No default value would normally be entered in the license dialog during CANoe CANalyzer setup VSETUPKEY_ Serial Number that would No default value SERIALNUMBER normally be entered in the license dialog during CANoe CANalyzer setup VSETUPKEY LICENSEKEY License key of your No default value CANoe CANalyzer version that is normally entered in the license dialog during CANoe CANalyzer setup VCREATE FLEXNET_ Option to install a shortcut ACTIVATION SHORTCUT to the License Activation Wizard in the program menu folder Info Please note that for correct execution of CANoe CANalyzer it is important to keep the directory structure the same as defined in the installation pa
9. RANSFORMS CANoeTransform mst MyCANoeTransform mst q CANalyzer installation msiexec i CANoe CANalyzer msi TRANSFORMS Instanceld1 mst CANalyzerTransform mst MyCANalyzerTransfor m mst q Of course further properties can be set to customize the installation Therefore you can use the defined properties described in chapter 3 1 Examples Setting the desired language to German VPROGRAM LANGUAGE 49 Setting the installation directory INSTALLDIR C Programs My Vector Folder CANoe 7 5 Vector Informatik GmbH Version 1 4 21 Further Installations Administration Manual CANoe CANalyzer MSI Setup 4 2 Service Pack Installation 4 2 1 Prerequisites Prerequisites A service pack installation can only be executed if a CANoe CANalyzer of the same main version but lower SP level is already installed Otherwise a full installation has to be done The service pack installation is compressed as self extracting executable when downloaded from the web In case you want to run the installation interactively just start the executable Otherwise e g for silent installation or deployment load the executable in a ZIP utility e g WinZip or 7 Zip and extract the contents first 4 2 2 Silent Update Silent Update For a silent update the following parameters have to be set at the command line msiexec i CANoe CANalyzer msi REINSTALLMODE vomus REINSTALL ALL IS MINOR UPGRADE 1 q In case multiple instances are ins
10. ance SAS Vector GB Ltd Vector Informatik GmbH Ingersheimer Str 24 70499 Stuttgart Germany Phone 49 711 80670 0 Fax 49 711 80670 111 mailto info de vector com http www vector com Vector CANtech Inc Suite 550 39500 Orchard Hill Place Novi Mi 48375 USA Phone 1 248 449 9290 Fax 1 248 449 9704 mailto info us vector com http www vector com Vector France SAS 168 Boulevard Cam linat 92240 Malakoff France Phone 33 1 4231 4000 Fax 33 1 4231 4009 mailto information fr vector com http www vector com Vector GB Ltd Rhodium Central Boulevard Blythe Valley Park Solihull Birmingham West Midlands B90 8AS United Kingdom Phone 44 121 50 681 50 Fax 44 121 50 681 66 mailto info uk vector com http www vector com O Vector Informatik GmbH Version 1 4 Appendix A Address Table 23 Appendix A Address Table Vector Informatik India Private Limited Vector Japan Co Ltd Vector Korea IT Inc VecScan AB 24 Vector Informatik India Private Limited 4 1 1 1 Sutar Icon Sus Road Pashan Pune 411021 India Phone 91 9673 336575 Fax mailto info in vector com http www vector com Vector Japan Co Ltd Seafort Square Center Bld 18F 2 3 12 Higashi shinagawa Shinagawa ku 140 0002 Tokyo Japan Phone 81 3 5769 7800 Fax 81 3 5769 6975 mailto info jp vector com http www vector com Vector Korea IT Inc 1406 Mario Tower Guro dong G
11. ckage Modifying this directory structure can lead to erroneous behavior which can lead to wrong simulation results Info You MUST NOT change anything else than the public properties specified in the table above Info Starting with Windows Vista installing the application and user data in the system program folder e g C Program Files is not supported If you install CANoe CANalyzer in the system program directory e g C Program Files Vector CANoe 7 5 you must not set the value of the property VAPPLICATION AND DATA ROOT to 3 Vector Informatik GmbH Version 1 4 15 Settings Administration Manual CANoe CANalyzer MSI Setup 3 2 Selectable Applications Applications The following applications are de selectable by the user CANoe_GUI CANalyzer_GUI CANdb_GUI CAPLBrowser_GUI GenTools_GUI PanelEditor_GUI Demos_GUI IP_Driver_GUI only installed with CANoe IP CANalyzer IP VV V V V V Vv Info The IP drivers Feature IP_Driver_GUI cannot be installed silently When installing the IP drivers user interaction is always necessary Info Note that additionally to the user s feature selection a feature will only be installed if the installation key contains the feature e g CANoe will not be installed if you licensed CANalyzer software Advertising is not supported for any of the features included in the setup software 3 3 Transforms Selecting name of product to be installed Installing multipl
12. ckage itself checks which Redistributables need to be installed Installation Install the CANoeCANalyzerRedistributable msi packet before installing the CANoe CANalyzer MSI packet Info CANoe CANalyzer Redistributables must only be installed on 32 bit operating systems 2 8 CANoe CANalyzer Redistributables for 64 Bit Operating Systems Prerequisites Some CANoe CANalyzer Redistributables need to be installed to use CANoe CANalyzer on 64 bit operating systems These Redistributables do not bring their own setups so that they are integrated in one single Windows Installer packet Installation check There is no check needed Just install the redistributable package The package itself checks which Redistributables need to be installed Info CANoe CANalyzer Redistributables Package for 32 bit operating systems has to be uninstalled before you install the 64 bit package The 32 bit package can be identified by its product code FF9E31CF F433 48FD 989E A6E9A3FCFC01 Installation Install the CANoeCANalyzerRedistributable x64 msi packet before installing the CANoe CANalyzer MSI packet on 64 bit operating systems 2 9 MSXML 6 0 Parser and SDK Prerequisites MSXML 6 0 Parser and SDK SP1 or MSXML 6 0 Parser and SDK SP1 Security Update KB933579 need to be installed to use CANoe CANalyzer Installation check On Windows Vista and later the MSXML 6 0 SP1 Parser and SDK is already installed To check if the MSXML 6 0 Parser and SDK is
13. e instances of one product 16 The MSI setup is able to install both Vector CANalyzer and Vector CANoe to the same machine For this purpose the MSI setup contains different embedded transforms These embedded transforms must be executed in any case in order to set the product name correctly The selected name will be displayed in the Add Remove Programs dialog When installing you need to specify the product you want to install gt For Vector CANalyzer use CANalyzerTransform mst gt For Vector CANoe use CANoeTransform mst Only the transforms mentioned above are supported You can only use the transform for the product for which you received license information installation key The Vector CANoe CANalyzer MSI setup does not enable you to install an arbitrary number of instances of the same product on one PC However a limited set of product codes is mentioned in the Setup ini file that comes with the installation package For each product code there is an entry in Setup ini Instanceldl Instanceld 1 ProductCode F041B692 0ED2 41B7 8457 25E918271439 Version 1 4 Vector Informatik GmbH Administration Manual CANoe CANalyzer MSI Setup Settings Those product codes can be used to install multiple versions of the product by using them for instance transformation Every product code in Setup ini can be used for either installing CANoe or installing CANalyzer Be aware that you have to manage all sub
14. for your ordered CANalyzer 20 Version 1 4 Vector Informatik GmbH Administration Manual CANoe CANalyzer MSI Setup Further Installations Creating an own transform mst for the command line For both examples above the installation is executed on the command line setting various public properties In case an own transform mst should be created to install CANoe and or CANalyzer you have to set the respective properties as shown for the command line Therefore create a transform for CANoe e g MyCANoeTransform mst and one for CANalyzer e g MyCANalyzerTransform mst and set the following properties in the Property table In case the respective property is not yet available in the Property table insert it and set the desired value Info Property names are case sensitive For both installations Property Value VSETUPKEY_CUSTOMER lt customer gt VSETUPKEY_SERIALNUMBER lt serialnumber gt VSETUPKEY_LICENSEKEY lt licensekey gt CANalyzer installation Property Value ProductCode F041B692 0ED2 41B7 8457 25E918271439 This is the value from Instanceld1 defined in Setup ini MSINEWINSTANCE 1 Info When installing CANoe or CANalyzer you also have to apply the embedded transform CANoeTransform mst and CANalyzerTransform mst respectively beside your own generated transform For this example the command line then has to be set as follows CANoe installation msiexec i CANoe CANalyzer msi T
15. he Microsoft Visual v7 2 SP1 C 2008 redistributables package installed Installation check To verify that the Microsoft Visual C 2008 redistributables are installed check if the software with the following product code is installed 9A25302D 30C0 39D9 BD6F 21E6EC160475 Installation To install the Microsoft Visual C 2008 redistributables silently use the following command vcredist_x86 vs2008 SPl exe q 2 13 Microsoft XNA 2 0 Redistributables Installation check To verify that the Microsoft XNA 2 0 redistributables are installed check if the software with the following product code is installed 245F6C7A 0C22 4DE0 8202 2AAA620A1D3A Installation The Microsoft XNA 2 0 Redistributables are provided as a Windows Installer Package You can install it using the package xnafx20 redist msi Vector Informatik GmbH Version 1 4 11 Setup Prerequisites Administration Manual CANoe CANalyzer MSI Setup 2 14 Microsoft DirectX February 2010 Redistributables Installation check Installation 12 There is no way documented by Microsoft for checking the installation state of the Microsoft DirectX February 2010 Redistributables A check is done by the installation routine of these redistributables itself Hence it is recommended to always execute the installer To install the Microsoft Visual C 2008 redistributables silently use the following command DXSetup exe silent Note that all f
16. iles required for installing the Microsoft DirectX February 2010 Redistributables can be found in a subfolder directx feb2010 redist Version 1 4 Vector Informatik GmbH Administration Manual CANoe CANalyzer MSI Setup Settings 3 Settings In this chapter you find the following information 3 1 Customizable Properties page 14 3 2 Selectable Applications page 16 3 3 Transforms page 16 Vector Informatik GmbH Version 1 4 13 Settings Administration Manual CANoe CANalyzer MSI Setup 3 1 Customizable Properties Properties for using The MSI setup was created to ease the deployment of CANoe CANalyzer in large IT software deployment networks via software deployment systems To support this the options that can be systems Public properties 14 changed in the user interface setup are represented by public properties Note that CANoe and CANalyzer are complex software utilities whose correct execution depends on some settings you might want to change Only change the settings available through the properties described in the following table otherwise a correct setup execution can not be guaranteed The following table lists the public properties and their meaning as well as their standard or predefined values respectively Note In case one of the following public properties shall be set to a customized value the respective property and its value gt have to be either directly provided on the msiexec command line or
17. k GmbH Administration Manual CANoe CANalyzer MSI Setup 2 Setup Prerequisites In this chapter you find the following information 2 1 2 2 2 3 2 4 2 5 2 6 2 7 2 8 2 9 2 10 2 11 2 12 2 13 2 14 Overview Windows Installer 3 1 Visual Basic Runtime 6 0 SP3 NET Framework 3 5 SP1 Windows Updates for NET Framework 3 5 SP1 Visual J 2 0 Redistributables CANoe CANalyzer Redistributables CANoe CANalyzer Redistributables for 64 Bit Operating Systems MSXML 6 0 Parser and SDK Microsoft Visual C 2005 SP1 Redistributable Common Controls Microsoft Visual C 2008 Redistributable Microsoft XNA 2 0 Redistributables Microsoft DirectX February 2010 Redistributables Vector Informatik GmbH Version 1 4 Setup Prerequisites page 8 page 8 page 8 page 8 page 9 page 9 page 10 page 10 page 10 page 11 page 11 page 11 page 11 page 12 Setup Prerequisites 2 1 Overview Prerequisites Setup programs Administration Manual CANoe CANalyzer MSI Setup Several prerequisites must be met in order to install and or use CANoe CANalyzer Those prerequisites will be listed in the following sections Please ensure that every client meets these prerequisites before installing CANoe CANalyzer You can find the setup programs for all prerequisites in the setup directory on your CD under CANoe Redist 2 2 Windows Installer 3 1 Prerequisites Windows Installer 3 1 or later is needed in order to install CANoe CANalyzer
18. lently use the following command dotnetfx35 spl exe lang enu q norestart It is recommended to install either the German or the Japanese language pack for NET Framework 3 5 SP1 on German respectively Japanese systems To install it silently use the following command gt German dotnetfx35langpack x86de exe q norestart gt Japanese dotnet fx35langpack x86ja exe q norestart Please note that there are different installation packages for x86 and x64 systems The samples above are valid for x86 systems The installation packages for x64 systems are called dotnetfx35langpack_x64de exe respectively dotnetfx35langpack x64ja exe Note The NET Framework 3 5 SP1 is delivered with Windows 7 You must use Turn Windows features on or off in the Control Panel to install or configure Microsoft NET Framework 3 5 SP1 For more information on this see http social msdn microsoft com Forums en US netfxsetup thread 35d348e5 192e 4fa2 a45a c1c2175ce111 Please note that also the language packs cannot be installed on Windows 7 Updates for NET Framework 3 5 SP1 After installing the Net Framework 3 5 SP1 it is recommended to immediately install also the update KB959209 in order to address a set of known application compatibility issues This update consists of several files which are provided for each relevant target system See http support microsoft com kb 959209 en us for details It is assumed that there is a strategy for instal
19. licensekey gt Set the values for lt customer gt lt serial number gt and lt license key gt and provided from Vector for your ordered CANoe CANalyzer installation Since CANoe is already installed a new instance has to be installed using an instance transform msiexec i CANoe CANalyzer msi TRANSFORMS InstanceId1 mst CANalyzerTransform mst MSINEWINSTANCE 1 VSETUPKEY CUSTOMER lt customer gt VSETUPKEY SERIALNUMBER lt serialnumber gt VSETUPKEY LICENSEKEY lt licensekey gt q MSINEWINSTANCE 1 Specifies that a new instance will be installed TRANSFORMS Instanceldl mst CANalyzerTransform mst Applies the embedded transforms Instanceld1 for installing a new instance and CANalyzerTransform for setting the product name to CANalyzer Choosing Instanceld1 mst will set the product code for your CANalyzer installation as specified in Setup ini in the section Instanceld1 Info All instance transforms Instanceld1 Instanceld100 are embedded transforms i e when selecting an instance transform set a prior to the desired transform VSETUPKEY CUSTOMER lt customer gt VSETUPKEY SERIALNUMBER lt serialnumber gt VSETUPKEY LICENSEKEY lt licensekey gt Set the values for lt customer gt lt serialnumber gt and lt licensekey gt and provided from Vector
20. ling Windows updates on your client computers and that there are rules on how such Windows updates shall be applied Thus no further information on this topic is given here 2 6 Visual J 2 0 Redistributables Prerequisites Installation check Installation The Visual J 2 0 Redistributables need to be installed in order to use CANoe CANalyzer To check if the Visual J 2 0 Redistributables are installed please check if the following registry key is present HKEY LOCAL MACHINE SOE TWARE Microsoft Visual JSharp Setup Redist v2 0 50727 If this registry key exists the Visual J 2 0 Redistributables are installed To install the Visual J 2 0 Redistributables silently use the setup program vjredist exe with the following command vjredist exe q a c install q It is recommended to install either the German or the Japanese language pack for NET Framework 2 0 SP1 if needed To install it silently use the following command vjredist LP exe q a c install q Vector Informatik GmbH Version 1 4 9 Setup Prerequisites Administration Manual CANoe CANalyzer MSI Setup 2 7 CANoe CANalyzer Redistributables Prerequisites Some CANoe CANalyzer Redistributables need to be installed to use CANoe CANalyzer These Redistributables do not bring their own setups so that they are integrated in one single Windows Installer packet Installation check There is no check needed Just install the redistributable package The pa
21. riction of warranty 1 2 4 Support You need support Vector Informatik GmbH has ISO 9001 2008 certification The ISO standard is a globally recognized quality standard We reserve the right to change the contents of the documentation and the software without notice Vector Informatik GmbH assumes no liability for correct contents or damages which are resulted from the usage of the user manual We are grateful for references to mistakes or for suggestions for improvement to be able to offer you even more efficient products in the future You can get through to our hotline at the phone number 49 711 80670 200 or you send a problem report to the CANoe Support 1 2 5 Registered Trademarks Registered trademarks All trademarks mentioned in this user manual and if necessary third party registered are absolutely subject to the conditions of each valid label right and the rights of particular registered proprietor All trademarks trade names or company names are or can be trademarks or registered trademarks of their particular proprietors All rights which are not expressly allowed are reserved If an explicit label of trademarks which are used in this user manual fails should not mean that a name is free of third party rights gt Outlook Windows Windows XP Windows 2000 and Windows NT are trademarks of the Microsoft Corporation gt CANoe and CANalyzer are trademarks of Vector Informatik GmbH Version 1 4 Vector Informati
22. sequent operations on the product instance yourself E g when installing multiple instances of Vector CANoe you need to take care to use the correct instance s product code when uninstalling one of them Vector Informatik GmbH Version 1 4 17 Administration Manual CANoe CANalyzer MSI Setup Further Installations 4 Further Installations In this chapter you find the following information 41 Silent Installation Example page 20 4 2 Service Pack Installation page 22 Prerequisites Silent Update 4 3 Update of 7 5 Pre Release page 22 44 Hardware Installation page 22 Vector Informatik GmbH Version 1 4 19 Further Installations Administration Manual CANoe CANalyzer MSI Setup 4 1 Silent Installation Example Silent Installation Installing CANoe and CANalyzer on the same machine silently example p Installation sequence First CANoe then CANalyzer Command line only CANoe installation msiexec i CANoe CANalyzer msi TRANSFORMS CANoeTransform mst VSETUPKEY CUSTOMER lt customer gt VSETUPKEY SERIALNUMBER lt serialnumber gt VSETUPKEY LICENSEKEY lt licensekey gt q TRANSFORMS CANoeTransform mst Applies the embedded transform CANoeTransform for setting the product name to CANoe The shows that the transform to be applied is embedded in the MSI VSETUPKEY CUSTOMER lt customer gt VSETUPKEY SERIALNUMBER lt serialnumber gt VSETUPKEY LICENSEKEY lt
23. talled on the machine you can specify the instance to be updated by adding the parameter n Product Code Info The parameter n Product Code must not be set in case you want to update a CANoe CANalyzer installation which was installed using the base product code The base product code is defined in the file Setup ini in the section Startup 4 3 Update of 7 5 Pre Release Technical The pre release version of CANoe CANalyzer 7 5 is technically a different product Information than CANoe CANalyzer 7 5 in terms of the product codes used Silent Update To update the CANoe CANalyzer 7 5 pre release version you first have to remove the pre release installation After this you have to install the CANoe CANalyzer 7 5 with the same properties as the pre release was installed Note that you need to provide your license information again The license information of the pre release version is still valid with CANoe CANalyzer 7 5 4 4 Hardware Installation Installation The drivers for Vector hardware interfaces are not installed via the Windows Installer setup At the moment there are no Windows Installer installations available for Vector hardware drivers You have to ensure that the drivers for the used Vector hardware are installed on the target machines 22 Version 1 4 Vector Informatik GmbH Administration Manual CANoe CANalyzer MSI Setup 5 Appendix A Address Table Vector Informatik GmbH Vector CANtech Inc Vector Fr
24. uro gu 222 12 Seoul 152 848 Republic of Korea Phone 82 2 8070 600 Fax 82 2 8070 601 mailto info kr vector com http www vector com VecScan AB Theres Svenssons Gata 9 417 55 G teborg Sweden Phone 46 31 7647600 Fax 46 31 7647619 mailto info se vector com http www vector com Version 1 4 Administration Manual CANoe CANalyzer MSI Setup O Vector Informatik GmbH Get more Information Visit our Website for gt News gt Products gt Demo Software gt Support gt Training Classes gt Addresses www vector com vector

Download Pdf Manuals

image

Related Search

Related Contents

Manual Caixas Acusticas PHT510    Português  Powermate VP0880467 Parts list  Wireless Smart On/Off Switch User`s Manual  EFI™ VUTEk GSLXr 3M™ Superflex UV Inks    CERASMART, CERASMARTMODUL, SUPRAPUR  Swann SW244-DWM User's Manual  維持管理要領書  

Copyright © All rights reserved.
Failed to retrieve file