1. INSIZE www insize com OPERATION MANUAL ISM CL150 Cold Light Illuminator lt INSIZEY lt INSIZEY User Manual This user manual is for users of ISM CL 150 series cold light illuminator To ensure the safety obtain optimum performance and to familiarize yourself fully with the use of this cold light illuminator we recommended that you study the instruction manual carefully Improper handing or neglect of the instruction could result in bodily injury or damage to the equipment Retain this instruction manual in an easily accessible place near the work desk for future reference Due to technical advancement the design of this illuminator is subject to improvement without notice The following safety symbols are found on the instrument Study the meanings of these symbols and always use the instrument in the safest manner Safety Symbols CAUTION The symbol is on the side surface of the power supplier Neglect of the symbol could result in bodily injury or damage to the instrument HOT SURFACE The symbol is on the lamp house cover During use the lamp and its periphery become very hot so should not be touched with bare hands HIGH TEMPERATURE lt INSIZEY Contents lSalebPiecaulioni gt coi ua ci i all 3 OV UNO o di la dei 4 2A ocio nie alli 4 2 2 Light GUIDE Assembly coeso aaa 5 2 3 Using the Instrument nah inni 5 3 Parts Replacement P_i 7 3 FUSE Replace MENE nn f 3 2
2. Lamp Replacement ooien T 4 Troubleshooting Guide iii 9 5 Maintenance and Storage Lilli 9 Mes WAV MINUS VAIN CS ile 9 0200000 ari 10 5 3 scheduled Check 00 eee ella 10 6 SPECINCAlionNe celata 10 lt INSIZEY 1 Safety Precaution 1 1 Purpose This instrument is only for illumination 1 2 No disassembly Do not disassemble any part of the equipment except those permitted as this may result in reduced performance electric shock bodily injury or damage to the equipment If there is any trouble do not hesitate to contact with the supplier please 1 3 Check the input voltage Make sure the input voltage accords with the required value before connecting the power cord Fig 1 1 FUSE TISUN 54 2404 TSI 1 4 Use specified power cord Always use the specified lamp and power cord Improper lamp and power cord may result in damage to the equipment or fire hazard Cold light T H lamp 21V 150W 1 5 Storage To prevent unnecessary trouble do not lay the equipment in a moist place If water is splashed onto to the illuminator turn off main switch at once to the o state disconnect the power cord and wipe off water with a dry cloth Make sure the equipment is placed in relatively independent room If foreign matter enters into the power supplier short circuit may be caused INSIZE 1 6 Precaution This illuminator is a precision instrument Handle it with care please Sudden or severe impact may resu
3. disconnect the equipment before lamp replacement e Make sure that the latch plate is pressed down and clicked is heard when the lamp house cover is laid back after lamp replacement INSIZE e The lamp would become quite hot during operation do not touch it with bare hands just after the lamp turned off e Make sure that the lamp is cooled down before lamp replacement To avoid burns do not touch the lamp during operation e To avoid fire hazard do not lay such things as scrim paper or other flammable solvents near the lamp 4 Troubleshooting Guide 4 1 Lamp does not light No power supply check the power cord connection 2 Lamp is not mounted properly mount the lamp properly Lamp is burned out replace the lamp Fuse is burned out replace the fuse Input voltage is improper check the voltage 4 2 Lamp is burned out frequently 1 Lamp of wrong type is used replace with a specified one 2 The input voltage is wrong select the right voltage 4 3 The illumination is not bright enough 1 Lamp of wrong type is used replace with a specified one 2 Light control is not adjusted properly adjust the light control 4 4 Lamp flickers Breadboard is burned out replace breadboard send it to the supplier to repair 2 Bad connection connect it properly 5 Maintenance and Storage 5 1 Maintenance Do not attempt to use organic solvents to clean the equipment or it will cause fad
4. ing or writing shed For intractable dirt wipe it away with gauze slightly moistened with a little scour INSIZE WARNING Be sure that the equipment is disconnected before cleaning and not used until the surface is dry 5 2 Storage The equipment should be stored properly Wrong handling or storage may exert a malignant influence on the equipment performance The storage should satisfy following conditions Do not subject the equipment to direct sunlight high temperature or humidity Lay the equipment in a clean place Do not place the equipment on vibrated bench which would reduce the performance Lay the equipment on a sturdy level table which can support the weight of the equipment 5 3 Scheduled Check In order to keep optimum performance scheduled check for the equipment is necessary About scheduled check contact with the supplier pls Specifications 1 Lamp Cold Light T H Lamp 21V 150W 2 Fuse T250V 5A 3 Standard Voltage 115V 230V 4 Outfit Double Light Guide 500mm
5. lt in damage to the equipment e Grip the handlebar when moving the equipment 2 Operation 2 1 Structure Main structure of power supplier is shown in Fig 2 1 and Fig 2 2 Switch of Lamp House fever Handie Bar Lighf Control Potentiometer AE Receptacle lt INSIZEY 2 2 Light Guide Assembly Insert light guide adapter into the light guide socket on the power supplier and then tighten two clamping screws as shown in Fig 2 3 Do not exert excessive force on the screws so as to avoid damage to the light guide Light Guide Socket Clamping Screw Light Guide Adapter ight Guide Fig 2 3 2 3 Using the illuminator ale Check the input voltage and choose the proper one by voltage selector switch on the rear panel of the power supplier Fig 2 4 11 3 Make sure that the main switch power is turned off in o state Fig 2 5 Before using rotate the light control to MIN Fig 2 5 Connect the power cord plug to the AC receptacle on the rear panel of the power supplier 2 4 then insert the power cord plug into the wall outlet Fig 2 4 Turn on the main switch and rotate the light control to adjust illumination intensity to a proper extent Fig 2 5 The illumination center can be adjusted by regulating light guide Note Different shape for light guide of different model INSIZE light Control Potenfiometer Fig 2 5 lt INSIZEY e The
6. power cord is vulnerable when bent or twisted Never subject it to excessive force Always use the supplied power cord If it is lost or damaged choose the same specification power cord please e Turn on the main switch to verify that the fan can work well Otherwise the heat can not be expelled properly which could result in damage to other parts In this case turn off the power switch right now and contact with the supplier to change the fan 3 Parts Replacement 3 1 Fuse Replacement Fig 3 1 Make sure that the main switch is set to off o state and the power cord is unplugged before fuse replacement Rotate the broken fuse Qout of the fuse holder with screwdriver and replace with a new one e Rated value for the fuse T250V 5A 3 2 Lamp Replacement Fig 3 2 Fig 3 3 Make sure that the main switch is turned off and the lamp is cooled down before lamp replacement cooling time 10 15 minutes Rotate the switch of lamp house cover Qand take the cover out In the lamp house trip the throw rod in the arrowhead direction so that the lamp can be jacked up Then unplug the lamp receptacle and take the lamp out Now replace with a new lamp INSIZE Fig 3 2 Fig 3 3 Fig 3 4 e As shown in Fig 3 4 during the lamp replacement when lamp house cover is taken out the latch plate would spring thus the power supply is automatically cut off However for the sake of safety it is preferable to