Contents

1. FS 41 45 The OUT2 and OUT3 outputs low current up to 50mA are programmable and each of them can serve one of the fifteen functions 0 not used 1 signaling of alarm to be cleared e g visual signaling 2 keypad alarm 3 READY status 4 armed status 5 indicator of AC battery or telephone line trouble 6 AC loss indicator 7 battery trouble indicator 8 telephone line trouble indicator 9 GROUND START signal 10 telephone line relay 11 monostable output MONO 12 bistable output Bl 13 RESETTABLE power 14 DURESS alarm 15 monitoring acknowledgement The number of output function corresponds to the number programmable in the FS 48 and FS 50 service functions to determine the output function The OUT2 and OUT3 outputs control the ground negative terminal of termination resistance The power supply outputs for the detectors AUX and keypad KPD have a common time delay cut out limiting the current consumption from the power supply by the external devices to 400mA All the outputs are protected against inductive loads and impulse interference LED KEYPADS In the LED keypads basic information concerning the system status is provided by means of light emitting diodes LED for detailed description see the user manual Displayed are the status of zones and system supervision alarm information on power supply status detection of emergency situation and operation i
2. e entry delay 30 seconds for zone 1 e zone 1 Z1 entry exit line EOL violation will generate chime signal in the keypad e zones 2 to 4 22 Z4 instant EOL may not be violated during arming e zone 5 Z5 24h tamper line EOL e sensitivity of all zones 480 ms e OUT1 output audible alarm duration 60 seconds shorted to ground during alarm assigned to all zones e OUT2 output visual alarm duration until cleared e OUT3 output failure indicator for AC supply battery or telephone e monitoring disabled e downloading disabled The above settings can be restored by using the FS 74 service function restart settings except for the service and user access codes which are restored by the FS 75 function restart codes Installation Guide 21 TECHNICAL DATA Main board supply voltage access o A Ne hoi ho ae oa acs Sak Saad aos AC 17 24V Main board current consumption 2 42 0 al Walia alia di 70mA Keypad current consumption min max cocoooccccccccccccccnnnanonanononnnnnnnnnnnnnnnnnnnnnnnos 35mA 85mA Power supply rated voltage ooooooccccccccccccccocoooccncncccnnnnnnnnnnncnnnnncnnnnnnnnnnannnnnnos DC 13 6 13 8V Total capacity of power SUD ases 1 2A Standby power supply recommended battery 12V 7Ah Battery Charging cuirrentya6 atari ode 350mA Battery OM I CIQHE LS LL aires oro es 3 15A delay Battery cut off VOM AC a a a ol a ne 9 5V 0 3V Number of progr
3. Assign codes to the events which are to be reported by by the control panel e g using the FS 57 function program the zone alarm codes 7 Enable monitoring FS 10 Option 1 REMOTE PROGRAMMING DOWNLOADING In order to facilitate its programming the CA 5 control panel has been equipped with a DOWNLOADING feature which enables a computer to be used for programming and control of the security system The programming may be effected directly through the control panel RS 232 port with TTL standard signals or by means of a modem through the telephone line terminals TIP and RING MODEM Interfacing with the computer by means of the modem can be performed in two ways either in the remote mode by means of the telephone cable network or in the local mode In both cases the computer must be equipped with a modem The local mode of programming can be entered by connecting the modem directly to the properly polarized TIP and RING telephone terminals of the control panel see Figure 3 The telephone line must be disconnected from the control panel CA 5 CONTROL PANEL SO666666666060666666 S6666 per OUT1 OUT2 OUT3 AUX KPD DTACLK COM Z1 Z2 COM Z3 Z4 COM Z5 TIP RING T 1 R 1 AUX 12V To modem Resistor 2200 Figure 4 Polarization of telephone line terminals in order to activate local communication with the computer NOTE Some modems require a capacitor of at least 1uF to be connected in the circuit to separate the const
4. for some of the security system consumers e g APS 15 APS 30 manufactured by SATEL Table 1 at the end of this manual shows an example of estimated balance of current consumption by the system and an example of battery selection Two emergency power supply wires connect the red one to the battery terminal and the black one to the battery terminal The battery circuit is protected with a WTA T 3 15A fuse The JP1 RESET pins make it possible to start the service mode without entering any service code This function can be disabled by the installer with the software means see FS 9 Option 1 The RS232 TTL connector is intended for programming the alarm system parameters from the computer As the control panel sends and receives a TTL standard signal OV 5V the RS ports of the panel and the computer must be connected with a special cable manufactured by SATEL The cable includes a converter changing the signal into a standard corresponding to the RS 232 connector in the computer 12V 12V The data can be transmitted through the cable in both directions NOTES e The connector may only be used when programming the panel Never leave the RS cable permanently attached e Do not short or touch the pins with your fingers e Prior to connecting the cable the installer should remove the electrostatic charge e g by touching a grounded equipment faucet heater etc with the top of his hand Installati
5. panel The list of service functions as well as the method of introducing and changing of system parameters by means of the keypad have been described in a separate instruction called PROGRAMMING LIST If the service code is unknown as its contents was previously changed it is necessary to carry out the procedure of entering the service mode from the pins This procedure is presented together with the description of service functions in the Programming List NOTE Blinking of all LEDs and sound signals given at the same time by the keypad indicate that there is a faulty connection no communication with the control panel the cable connections must be checked If the suggested procedure turns out to be unsuccessful the option to enter the service mode from the pins must have been disabled in the control panel by software means If this is the case it is necessary to carry out another procedure which would unblock the control panel and restore the factory settings see description of the FS 9 service function in the Programming List 18 Alarm Control Panel CA 5 SATEL After completing the procedure exit the service mode using the FS 0 function and call the service mode again this time from the keypad entering the factory access code 1 2 3 4 5 and accepting it with the key Re entering the service mode by the control panel means that the equipment operation is correct and programming of all necessa
6. the housing It is advisable to make sure that the plug when pressed does not slip out from the opening During installation of the housing be careful so as BESSI not to damage the wires which will be passed through the hole in its back panel Figure 6 When the housing is secured you can install the control panel main board and proceed to making the connections BEND ASIDE wu a Y lt a Z wu m CONNECTION OF POWER SUPPLY It is required that the control panel be permanently connected to the mains power Therefore prior to starting the work on the system cabling make yourself familiar with the electrical installation of the site and select a circuit which is permanently alive to power the control panel The circuit is to be protected with an appropriate fuse CAUTION The control panel is power supplied from the 230V AC mains Carelessness or wrong connection may result in electric shock and pose a threat to life Therefore exercise particular caution when connecting the control panel In the process of installation and connection of the control panel the cable to be used for mains supply must not be alive Description of electrical connections to the CA 4 5 6 OBU housing The AC power supply unit encased in the plastic box is fully electrically isolated from the metal housing Connect the 230V alternating voltage leads to the transformer terminals marked AC 230V Connect the output voltage wi
7. A 5 SATEL LCD S LCD L KEYPAD The LCD S LCD L keypad works in conjunction with the CA 5 panels having software in version 1 03 or later It performs identical functions as the LED keypad The liquid crystal display 2x16 characters facilitates the system communication with the user and the installer The LCD S LCD L keypad can be connected in parallel with the LED type keypads or with other LCD keypads There are available two version of LCD keypads CA 5 KLCD L and CA 5 KLCD S that differ in the dimension and the size of display ANTI TAMPERING CONTACT BUZZER TERMINALS FOR WIRES Figure 3 CA 5 KLCD S keypad board MONITORING The CA 5 control panel can transmit information on the system status to a monitoring station to one or two telephone numbers in various transmission formats The control panel will dial the second number of the station when the first number is busy or the station does not confirm reception of the code Irrespective of which number is reached by the control panel all events are transmitted It is possible to send information on the events concerning arming disarming zones alarms tampering as well as system events Information can be sent to the station in one of the fifteen transmission formats including the Contact ID Owing to analysis of the commutation signals the CA 5 control panel controls the process of establishing connection with the station which in case of high occupancy o
8. ET 16 TELEPHONE LINE SWITCH cool ia dai aii 16 STARTING THE CONTROL PANEL sunnnnnnnnnnnnnnnnnnnnnnnnnnsnnnsnesse 17 DEOADTONPROGRAM iremen M SR RS Sn ne nine Sune DEA Si St si ont tn nent 18 PROGRAM CONFIGURATION TO ESTABLISH COMMUNICATION WITH THE CONTROL PANEL 18 DEFAULT SETTINGS cccssssssssrsessesssssssrsesscsrsessessrsessessssessessssessessssessesersesscsersesscssssnssesensessesscsessesscsesenssesensesessenees 20 TECHNICAL DATA csssssssssesssssrsessessrsessessssessessrsesscssssessessesessasessesscssesessasensessasessessasessessessesessesesessessesessessessesesesers 21 GENERAL The CA 5 alarm control panel is an advanced microprocessor based device designed for burglary and assault signaling systems It is characterized by a high programming flexibility which facilitates its use in systems which have to meet special requirements The device is equipped with a reliable pulse type power supply of high efficiency and with a telephone communicator dialer It is designed to be operated by means of remote keypads connected with a four wire line and is capable of being programmed by means of a computer and the DLOAD10 program working in the WINDOWS environment BASIC FUNCTIONAL CAPABILITIES 5 zones with programmable operating modes Compatibility with any detectors NO NC in various configurations without resistance or with a single or a double parametric resistor 3 signal outputs serving the following p
9. F Tes AZ MODEM Zoltrix FM VSP56i3 e3 on Coml nitializina DK AT B1E0V1Q0N0S37 3 ATBIEOVIQON0S37 3 AT S0 059 157 120510 255 ATS0 059 157 120510 255 cd 7 OK MODEM READY gt vsx _X Carca Connect remote local CAS hardware Figure 13 Dialog windows of the DLOAD10 program 115200 20 Alarm Control Panel CA 5 SATEL In order to start communication through the RS port or modem you should follow the procedures set forth in the section REMOTE PROGRAMMING DOWNLOADING After correct initialization of the operation close the configuration windows and click on the icon or select the MODEM command from the COMMUNICATION menu The program will open a window enabling a connection to be made and will prompt further procedures The control panel type is recognized automatically after establishing connection or it can be selected through the File menu Calling the downloading function with the communication established the hal icon can speed up the subsequent process of uploading changes made to the panel software DEFAULT SETTINGS The control panel is preprogrammed for work in the following configuration e service code 12345 e master code 1234 e panel communication code 3736353433323130 e computer communication code 3031323334353637 e number of rings before answer 2 e exit delay 30 seconds e keypad alarm duration 30 seconds
10. INSTALLATION GUIDE c 0 QO O 5 joa c O O hom lt x Satel GDANSK POLAND ca5i_e 06 04 A WARNINGS Due to safety reasons alarm system should be installed by qualified personnel only Telephone terminals of the panel should be connected to PSTN lines only Connecting to ISDN lines may lead to damage of the equipment Because alarm system may contain hazardous items its components should be kept out of reach of unqualified personnel In order to avoid the risk of electric shock read carefully this manual before proceeding to installation Any connections should be made in deenergized state only i e with power supply disconnected In the event of service operations consisting in fuse replacement they must only be carried out after disconnecting the supply voltage For the replacement use only the fuses which have identical parameters as the original ones It is recommended that the manufacturer s required housings and power supply units be used Making any construction changes or unauthorized repairs is prohibited This applies in particular to modification of assemblies and components CAUTION It is impermissible to connect a fully discharged battery voltage on terminals without a load less than 11V to the alarm panel To avoid hardware damage fully discharged or never used battery should be charged initially using proper charger The batteries used in the alarm systems contain lead The ol
11. ammable zones se 5 Number of programmable outputs ss 2 Current carrying capacity of OUT1 alarm output 3 15A Current carrying capacity of OUT2 and OUTS outputs eee eeeeeeeeeeeeeeeeeeeeeeees 50mA Control panel operation temperature range 0 55 Table 1 Example of panel power supply load estimation battery selection No Loads Max current Mean current consumption 1 Main board CA 5 70mA 70mA 2 Keypad output AUX and 5 detectors 400mA 200mA 3 Output OUTI 3 15A 0 5A 4 Outputs OUT 2 and OUT3 2 x 50mA 50mA 5 Battery charging current 350mA Total max current consumption by the system with XI 70mA 400mA 100mA 350mA 920mA no alarm signaling YAmax 1 25x 0 07x12 0 4x12 3 15x0 25 0 1x0 25 Battery selection based on max and mean current 8 1Ah consumption by the system assumed duration of power trouble 12h assumed 1 alarm with 15 min YAn 1 25x 0 07x12 0 2x12 0 5x0 25 0 1x0 25 0 25h duration of signaling 4 2Ah Recommended standby power supply battery 12V 7 5Ah Assumed current consumption by a single detector 20mA In case where the capacity of the power supply is exceeded the current is supplied by battery NOTES e It is impermissible to connect a fully discharged battery voltage on terminals without a load less than 11V to the alarm panel To avoid hardware damage fully discharged or never used battery should be charged initially using p
12. ant voltage polarizing the control panel telephone input 8 Alarm Control Panel CA 5 SATEL Having initialized the modem in the DLOAD10 program see Section STARTING THE CONTROL PANEL and having selected the CONNECT locally command activate the FS 77 service function in the control panel When the communication is established download the control panel data and then proceed to download the events program parameters etc The remote mode of programming can be reached by establishing the telephone connection between the service computer and the control panel Initialization of the communication through the telephone line is possible in three modes 1 The computer calls the alarm control panel which having answered the call exchanges communication passwords with the computer If they are correct the control panel confirms reception of the remote programming order hangs up and calls the computer back to the number pre programmed in the control panel Before calling back the control panel notifies the monitoring station on starting the programming process 2 The computer calls the control panel and after handshaking the control panel proceeds directly to data exchange This simplified mode of establishing connection can be reached when no computer telephone number is entered on the control panel The monitoring station will be notified after communication with the computer is ended 3 Establishing communication on the control
13. ation with the input voltage of 17 24V_AC The control panel is fitted with an advanced pulse type power supply of high energy efficiency and operational reliability the correct functioning of which requires however that the input voltage at the maximum load of the transformer by the control panel never drop below 16V AC The control panel power supply current efficiency 1 2A is fitted with voltage stabilization system the voltage value of 13 6V 13 8V is factory set during production process and should not be changed battery status monitoring system with optional disconnection of the battery if discharged during testing the processor reduces the power supply voltage to about 10 5V and the consumers are powered from the battery The testing takes place every 4 minutes and lasts for less than twenty seconds If the battery voltage drops down to about 11V the control panel will report a trouble In case of the voltage fall to 9 5V the control panel will cut off the battery in order to prevent it from being completely discharged and damaged Attention should be paid so as not to cause overloading of the control panel power supply in the security system It is advisable to make a load balance for the power supply The total current inputs for the consumers detectors keypads and the battery charging current may not exceed the power supply capacity In case of a higher electric power demand an additional power supply can be used
14. d batteries must not be thrown away but disposed of as required by the existing regulations European Directives 91 157 EEC and 83 86 EEC Latest EC declaration of conformity and product approval certificates can be downloaded from our Web site www satel pl CONTENTS GENERAL AAA essence encens eneneseenensene nee 2 BASIC FUNCTIONAL CAPABILITIES cscsssssssssssssssessssssessessssessssessessssessessssessessssssessesessessssessesessossessssessesessesees 2 CONTROL PANEL CHARACTERISTICS cccssssssssssssssssssssersssessersesessessssessessesessessesesessssesessesessessesessesseseesessesess 3 ZONES Suu o a 3 OU UTRUTSE Sn pi ina 3 LED KEY PADS sini adit eatin ota id 4 LCDS CCDE KEYPAD usan 6 MONITORING aa ent nor E ERE EEE AERO ESE E E ee ates Same tien RE OR SAG Re aes 6 MONITORING PERSONAL NOTIFICATION siennes 7 REMOTE PROGRAMMING DOWNLOADING iii 7 MODEM st ati repair in eee ee 7 RS 2322R ORL A NOA 9 INSTALLATION OF THE CONTROL PANEL cccssssssssssssssssssesscssssessessssessessssessessssesscssssessessesessessssessessssossesessesees 9 DESCRIPTION OF MAIN BOARD nono n ran nen nono anno n enr Dn NR On A ne nn nn nn EEE naar cnn RS n 9 CONNECTION OF POWER SUPPLY neonin a ee a a r E AE Rodin fete op 11 CONNECTION OF KEY PAD tos iia 12 CONNECTION OF DETECTORS ini de inner EEE RESE 14 CONNECTION OF SIGNALING DEVICES siennes 14 CONNECTION OF TELEPHONE EINE rras oee r SRE I E E EEE EERE A dee AEE a O
15. dem is necessary i e disabling the function of transmission standard negotiation and forcing operation with the rate of transmission of 300 Bps The program installation consists in running the setup exe program from a floppy disk delivered with the control panel After installation the program should be launched Access to the program is protected with an access code After installation of the program the access code is 1234 and can be changed in any string of 16 alphanumeric characters As long as the code has its factory form pressing the ENTER key without entering any code will start the program with the default access code 1234 Having started the program perform the configuration and initialize the RS 232 port or the modem by means of which the control panel will be programmed The further step can be selection of the control panel type CA 5 and starting of connection remote or local To facilitate using the program and programming the control panel parameters itself a HELP system is provided The system is accessible from the HELP menu or after pressing the F1 key from the computer keyboard In order to get an immediate access to more detailed information it is necessary to select the desired element in the program window by moving the mouse pointer onto it and clicking the left mouse button and then press the F1 key PROGRAM CONFIGURATION TO ESTABLISH COMMUNICATION WITH THE CONTROL PANEL In order to start conf
16. ected in parallel the TMP anti tampering contacts should be connected in series and the other keypad wires in parallel IMPORTANT If one of the system zones has been programmed as 24H TAMPER and used for protection of the system elements against tampering thus creating an anti tampering circuit violation of such a zone will trigger no alarm if the control panel is in the service mode If the control panel gives an alarm at the moment of exiting the service mode it can mean violation of the anti tampering line opening of one of the contacts CA 5 CONTROL PANEL oO Beeeessseeesessssss SSSss ae OUT1 OUT2 OUT3 AUX KPD DTACLK COM Z1 Z2 COM Z3 Z4 COM Z5 TIP RING T 1 R 1 TO ANTI TAMPERING CIRCUIT Sees KPD DTA CLK COM LCD KEYPAD Figure 8 Connection of LCD keypad to the CA 5 panel 14 Alarm Control Panel CA 5 SATEL CONNECTION OF DETECTORS Z5 programmed as 24H TAMPER CA 5 CONTROL PANEL 98888 i Pe OUT1 OUT2 OUT3 AUX KPD DTACLK COM Z1 Z2 COM Z3 Z4 COM Z5 TIP RING T 1 R 1 2x1 1kO NC NC TMP TMP COM 12V GND TMP TMP C NO 12V NC NC TMP TMP COM 12V NC NC TMP TMP COM 12V S66666 S66666 SSSSgsSs S666606 2EOL NO EOL EOL NO or for for or 2EOL NC NO NC NC AQUA AQUA AQUA AQUARING AQUARING AQUARING INDIGO INDIGO INDIGO Figure 9 Example of connecting 4 detectors in various configurations with ZS anti tampering circuit NOTE The real system anti tampering circuit should a
17. elay controlled visual signaling A 16 Alarm Control Panel CA 5 SATEL CA 5 CONTROL PANEL OUT2 programmed as Alarm to be cleared SO6666666660666666 SIA O a OUT1 OUT2 OUT3 AUX KPD DTACLK COM Z1 Z2 COM Z3 Z4 COM Z5 TIP RING T 1 R 1 O Triggering the audible and visual alarms in the signaling device when the outputs OUT1 and OUT2 are shorted to ground TO ANTI TAMPERING CIRCUIT GND 12V STO STA SAB SAB SS6S666 To ensure proper operation of the signaling device it is necessary to connect the bias SPLZ 1011 resistors to STA and STO inputs in the signaling device Signaling device ae Figure 11 Example of connecting the SATEL SPLZ 1011 signaling device OUTI audible signaling OUT2 visual signaling CONNECTION OF TELEPHONE LINE If the security system utilizes the control panel telephone communicator for remote programming or monitoring it is necessary to connect telephone line to the control panel It should be connected to a connector situated on the right side of the printed board In order to ensure proper operation of the dialer the control panel must be directly connected to the line connectors designated as TIP and RING and any other devices telephone telefax after the control panel connectors designated as T 1 and R 1 Such a connection will make it possible for the control panel to fully engage the line for the time of calling which prevents the monitoring function f
18. f the line considerably reduces the time between occurrence of the event and sending the information to the monitoring station Repeated dialing attempts are made immediately on discovering the busy signal as a result of which the connection is established many times faster than through the devices which wait for a specific signal during a pre determined time and only repeat the dialing attempt on discovering that the signal has not occurred Installation Guide 7 MONITORING PERSONAL NOTIFICATION The CA 5 panel monitoring function can be used for telephone notification of events taking place in the security system e g alarm or AC power failure Short audible signals characteristic of transferring data to the monitoring station will be heard in the telephone handset In order to initiate telephone messaging by means of audible signals the alarm control panel must be programmed as follows 1 Enter the control panel service mode 2 Call in the FS 76 function and delete all the monitoring codes 3 Using the FS 52 amp FS 53 functions program the telephone numbers to which the audible information on events is to be sent If the first number is busy the control panel will dial the second number 4 Select the 0 no handshake data transmission format in the FS 54 amp FS 55 functions 13 Ademco Slow without confirmations 5 By means of the FS 56 function set any four character control panel identifier e g 1111 6
19. iguration click on the icon the Configuration window will be opened The Port RS 232 tab enables the port number to be selected during direct Installation Guide 19 programming through the RS port of the control panel If the control panel is to be programmed by means of the modem select the Modem tab and click on the Details button Having opened the Modem window select the corresponding modem type from the list or click on the Change button and enter the data according to the documentation of your modem Clicking on this button will also allow you to change the communication port number or the rate of transmission The y Test button permits checking the modem operation with the program it opens a window containing information on the modem initialization Port RS 232 Modem Data y A Beith Beis Boma Zoltrix FM SP56i3 e3 eo Details Gon 2 Gon 4 Com G Dialing Tone IV Dial tones control Reset command jatz Initializing Baud Rate 300 C i200 g ZAG Speaker 4800 C Off f Auto C On TEOVIQONOS37 3 C 600 C Cc c c 18200 Volume 1 120510 255 oa 1152110 Answering Operation gt After 2 rings Auta y Y Chanae Change M A Test_ Manual Manual B dla Y OK X Cancel Port AS 232 Comi C Com3 C Coms C Com2 C Com 4 C Comb Zoltrix FM Y SP56i3 e3 R Modem ready
20. lso include the anti tampering contacts of keypad signaling devices control panel housing etc The circuit connected to the one parameter configured zone EOL is to be closed with a 2 2 kQ resistor In case of two parameter zone the detector output is to be closed with two 1 1 kQ resistors This type zones 2EOL allow the control panel to simultaneously monitor the status of detector and its anti tampering contact see Figure 9 The NO and NC detectors in two parameter configuration can be connected in the identical way it is only important to indicate to the control panel what type of detector is connected to the zone 2EOL NO or 2EOL NC The same is the case with the detectors having no parameter The AUX output is intended to be used for powering the detectors Separation of the detector power supply ground and the input line ground permits eliminating the adverse effect of the wiring resistance Assuming that the cable is not very long and that it has just one detector connected it is possible to make the installation simpler by leading the power supply ground wire GND and the signal ground wire in one conductor CONNECTION OF SIGNALING DEVICES Where signaling devices are used that give alarm when power supply is switched on the of signaling device power supply should be connected to the control panel OUT1 Installation Guide 15 terminal and the signaling device ground to the control panel OUT1 terminal In this
21. mode one independent signaling device can be set Where signaling devices with internal battery of their own are employed the OUT1 output should be used to power the signaling devices the signaling device ground should be connected to the control panel COM terminal and the triggering signals should be provided by the OUT1 output and the OUT2 and or OUT3 low current outputs Triggering alarm in the signaling devices must be effected with OV voltage by shorting the control input NOTE The polarization of outout OUT1 can be reversed FS 9 option 4 and then it operates in a different way than the low current outputs OUT2 and OUT3 do active state terminal OUT1 cut off no COM normal state terminal OUT1 shorted to COM The OUT2 and OUT3 outputs can be utilized to control the relays switching on any signaling devices or other equipment The relays can be directly connected to the outputs as shown in Figure 10 which presents connection of the SPL 2010 visual signaling device It should be borne in mind that these outputs can be loaded with a maximum current of 50mA OUT2 programmed as Alarm to be cleared CA 5 CONTROL PANEL Q SSSSSSSSSSSEEESSS 22228 e a OUT1 OUT2 OUT3 AUX KPD DTACLK COM Z1 Z2 COM Z3 Z4 COM Z5 TIP RING T 1 R14 TO ANTI TAMPERING CIRCUIT SO SA SAB S66666 Signaling device SPL 2010 Figure 10 Example of connecting the SATEL SPL 2010 signaling device OUTI audible signaling OUT2 r
22. n programming mode The way of keypads operation should be determined when programming the control panel FS 6 8 Provision is made for bypassing some functions for instance the option to trigger special alarms quick arming and determining which audible signals are to be transmitted by the keypad It is possible to signal the exit delay or the entry delay times zone violation with the chime option and alarm signaling The keypad illumination can be turned on permanently or activated automatically by pressing any key or alternatively by violating any zone when the system is in the armed mode The keypads have an individual NC type anti tampering contact TMP which opens after opening the enclosure or separating it from the base and which is to be included in the system anti tampering circuit The control panel checks the keypad for its presence in the system through the data bus DTA signal control Installation Guide 5 Description of terminals TMP anti tampering ANTI TAMPERING contact terminals CONTACT COM ground DTA CLK keypad data bus KPD power supply input 12V BUZZER KEYPAD CONTROL PANEL KPD Wire connections TERMINALS FOR WIRES DTA CLK COM Anti tampering contact terminals Vv Figure 1 CA 5 KLED M keypad board TERMINALS FOR WIRES AA ANTI TAMPERING CONTACT BUZZER Figure 2 CA 5 KLED S keypad board 6 Alarm Control Panel C
23. n the control panel main board O00 O lija O CA 5 RESET a a O Cc 1O F2 FS ases 500 EL TTL Bo YU o Eo est gt SSSS8 5858550505008 66666 E i OUT1 OUT2 OUT3 AUX KPD DTACLK COM Z1 Z2 COM Z3 Z4 COM Z5 TIP RING T 1 R 1 O 5W0 1QJ TO BATTERY RED BLACK ie Figure 5 View of CA 5 control panel main board version CASP V3 2 BOARD TERMINALS AC module power supply inputs 17 24V AC Z1 to Z5 zones OUT1 signaling output current carrying capacity 3 15A OUT2 OUT3 control panel programmable outputs current carrying capacity 50mA DATA CLK keypad bus terminals KPD keypad power supply output AUX detectors power supply output COM ground protective terminal ground connect to protective circuit only TIP RING external telephone line terminals T 1 R 1 internal telephone line terminals telephone set connection 10 Alarm Control Panel CA 5 SATEL The DIALER LED is lit up during telephone messaging by the control panel and blinks during pulse dialing Situated next to the LED is an adjustable resistor lts setting should not be changed since it would cause incorrect work of the dialer loss of the capability of dialing in the DTMF system and monitoring in the Ademco Ex i Contact ID formats The AC terminals are intended for the supply of alternating voltage from the mains transformer The control panel power supply is suitable for oper
24. of voltage on the telephone line Non volatile memory for the last 255 events Non volatile memory for all parameters and the last control panel status return to the status from before power supply was disconnected Installation Guide 3 CONTROL PANEL CHARACTERISTICS ZONES The CA 5 control panel has 5 zones all of them on the main board The control panel accept any detectors connected in the NC NO EOL 2EOL NC and 2EOL NO configuration The two parameter configuration 2EOL allows the control panel to simultaneously control the detector and its anti tampering circuit while using one pair of wires The zones can serve the following functions in the system 0 entry exit 1 interior delay 2 instant 3 counting to 2 throughout the monitoring time as determined by the entry delay 4 24h panic 5 24h fire 6 24h tamper 7 arming disarming alarm clearing 8 perimeter zone armed since entering the access code and confirming it with the key i e arming the partition Violation of this zone during countdown of the exit delay will trigger an alarm The number of zone function corresponds to the number programmable in the FS 26 30 service functions to determine the type of zone reaction The reaction time for each zone can be programmed from 0 016 s to 4 08 s FS 16 20 For the zones types 0 1 and 3 individual delay times can be set FS 31 35 For each zones it is possible to de
25. on FS 4 computer telephone number it is not necessary but provides higher protection against unauthorized access by the telephone line FS 5 number of rings before answer where the communication is to be initialized from the computer FS 11 option 1 if the DWNL function is to be initialized from the outside by the service computer e Cable connection telephone or local of the control panel with the computer modem e Launching the DLOAD10 program and initializing the modem operation e Setting identical communication passwords options and number of rings in the security system with those pre programmed in the control panel Installation Guide 9 RS 232 PORT The alarm control panel can be programmed through the RS serial port by means of a special cable designed for programming the CA 5 control panel In order to begin programming enter the Communication menu and select Connect locally with then select the control panel type CA5 RS 232 Start the FS 78 service function in the control panel Conformity is required between the communication codes of panel and computer FS 2 and FS 3 programmed in the control panel and included in the DLOAD10 program data INSTALLATION OF THE CONTROL PANEL DESCRIPTION OF MAIN BOARD The control panel main board contains electronic components sensitive to electric charges Prior to installation these charges must be removed During installation avoid touching any elements o
26. on Guide 11 e lt is recommended that the cable be connected first to the control panel connector and then to the computer connector The CA 5 main board enables an electric shock protection circuit grounding to be connected The protective cable terminal is designated by the symbol The neutral wire of the 230V AC mains supply must not be connected to it If the site has no separate electric shock protection circuit this terminal must be left free The telephone line must be a four wire line so that the control panel can be connected before the other devices telephone telefax etc CAUTION Do not send telephone signals and alarm system signals by one multicore cable This may result in a damage to the system in case of a high voltage punch through from the telephone line The CA 5 control panel should be installed in enclosed spaces with a normal humidity of air It can be mounted in the CA 6 OBU housing with a transformer designed for operation with the control panel power supply which permits installation of a battery with 7Ah capacity Before the housing is secured to the base it is necessary to mount inside the housing plastic distance plugs which are intended for subsequent installation of the main board In case the plugs tend to slip out the catches fixing the plug in the housing need to be slightly bent aside Figure 6 When inserting the plug press in the central part of the head firmly in so that it is blocked in
27. oned order the battery first then the 230V alternating voltage CAUTION As the control panel has no isolating switch to disconnect the mains supply it is important that the owner or the user of the security system be informed on how the system is to be disconnected from the mains e g by indicating the fuse which protects the control panel supply circuit CONNECTION OF KEYPAD The CA 5 control panel interfaces with SATEL made LED and LCD type keypads The keypad should be connected to the system with a four wire line using the COM KPD DTA CLK connectors on the control panel Where typical conductors are used the cable length can be up to 200m Provision is made for connecting additional keypads in parallel to the others Each keypad should be connected to the control panel by means of a separate cable If this is the case activation of the programming mode service or user one from any keypad will block the operation of the other keypads Installation Guide 13 CA 5 CONTROL PANEL o Bgesssssesessesees SeSe y _4gv OUT1 OUT2 OUT3 AUX KPD DTA CLK COM Z1 Z2 COM Z3 Z4 COM Z5 TIP RING T 1 R 1 TO ANTI TO ANTI LED M KEYPAD TAMPERING TAMPERING CIRCUIT CIRCUIT TMP TMP COM DTA CLK KPD TuPTHPCOM Du md Dt LED S KEYPAD Figure 7 LED keypads connection to the control panel The anti tampering contact NC of the keypad should be connected with the system anti tampering circuit Where two keypads are conn
28. panel side by means of the O function called by the master user or the service Having called the function the control panel dials the computer telephone number pre programmed with the FS 4 service function and after completion of the programming notifies the monitoring station Initialization of the connection by the computer can be disabled In order to reduce the telephone connection costs the transmission can be repeatedly suspended In case of a new connection the control panel does not inform the monitoring station of the remote programming as this is only done before the first call back Instead after receiving the communication termination command information on completion of the remote programming is sent to the station After suspending communication on the computer side the control panel is waiting four hours for a call even when the automatic call answering function is disabled If the communication is not terminated with the end but with the suspend command the information on terminating the communication is registered in the event memory and after four hours sent to the monitoring station Communication with the computer requires e The following to be programmed in the control panel FS 2 control panel password the identifier which allows the program to recognize the security system FS 3 computer password the identifier which allows the control panel to recognize computer authorized for communicati
29. res of the transformer secondary winding to the AC 18V terminals on the control panel main board A A 12 Alarm Control Panel CA 5 SATEL Connect the wire of the electric shock protection circuit to the terminal block provided next to the transformer and marked with the ground symbol This circuit should also be connected to the control panel protective terminal STARTING PROCEDURES FOR THE CONTROL PANEL POWER SUPPLY 1 Connect the emergency power supply wires to the corresponding battery terminals the red one to the battery plus the black one to the minus The control panel will not start on connecting the battery alone without the mains power connected however it will keep on working in case of the 230V AC voltage trouble provided it was started before 2 Switch on the 230V AC mains supply the control panel gets started Connection of the power supplies in the prescribed order will permit correct functioning of the power supply unit and the control panel electronic safety devices thus avoiding damage to the security system elements caused by possible installation faults IMPORTANT e Never switch on the control panel power supply until all the remaining connections are completed e f it is necessary to completely disconnect the control panel power supply the 230V alternating voltage should be disconnected first then the battery Re connection of the power supply is to be performed in the above menti
30. rom being blocked by lifting the handset Additionally the telephones connected after the control panel do not signal the dialing by the control panel CAUTION e Telephone terminals of the panel should be connected to PSTN lines only Connecting to ISDN lines may lead to damage of the equipment e System installer should give the necessary information on the way of connection with telephone network to system owner TELEPHONE LINE SWITCH The control panel has been fitted with the telephone line switch function which improves the efficiency of monitoring The function is served by the type 10 Telephone line switch output Where two telephone lines are available at the site this output can directly control the relay to switch over the telephone line connected to the TIP and RING terminals The output gets activated if problems occur with sending the code to both telephone numbers of the monitoring station The function works in the following way e The control panel dials the first number of the monitoring station in order to send the event code If it fails to send the code the other number of the station is dialed Installation Guide 17 e If connection to the second number fails the control panel switches over the telephone line and dials again the first number of the station When the problem recurs the control panel redials the second number e f the code is still not received by the station the control panel returns
31. roper charger e The control panel power supply unit has been designed for work with lead batteries or other batteries with a similar charging curve European Directives 91 157 EEC and 83 86 EEC A ATTENTION An efficient security system does not prevent burglary assault or fire from happening however it diminishes the risk that such a situation will cause no alarm or notification Therefore the SATEL Company recommends that operation of the whole security system be regularly tested SATEL sp z 0 0 ul Schuberta 79 80 172 Gdansk POLAND Tel 48 58 320 94 00 info satel pl www satel pl
32. ry parameters may be commenced A trouble with entering the service mode by hardware method points to incorrect performance of the above mentioned procedures DLOAD10 PROGRAM Delivered together with the control panel the DLOAD10 program is designed for programming the control panels CA 5 CA 6 CA 6 plus CA 10 and CA 10 plus as well as the radio controllers RX2K and RX4K from acomputer Furthermore the program makes possible creation of documentation for the security systems sets of settings for various configurations patterns which facilitate programming new systems sets of events for each system as well as remote control of the control panel identical as by means of the keypads The program is designed for IBM PC AT compatible computers It works in any computer hardware configuration in the WINDOWS 9x ME 2000 XP environment It is recommended that the program be installed on the computer hard drive The control panel communicates with the computer via the RS 232 TTL link or a telephone line For the telephone communication with the panel the program uses a modem controlled by one of the COM ports external or internal compatible with the HAYES AT Command standard Communication with the CA 5 control panel is possible in the BELL 103 standard at rate of 300 Bps As the control panel only transmits data at a speed of 300 bauds the modem must support this rate of transmission Usually a suitable configuration of the mo
33. termine four codes of events to be sent to the monitoring stations FS 57 58 i FS 60 61 The zone can be selectively bypassed with the user function 4 OUTPUTS The CA 5 is fitted with 3 signal outputs and 2 power supply outputs The OUT1 output high current fuse 3 15A is a specialized alarm output It is intended for connecting an audible signaling device This output has two terminals OUT1 and OUT1 Activation of the output is effected by grounding the OUT1 terminal It is possible to alter the way of work of terminal OUT 1 FS 9 option 4 Selection of the option Polarization OUT1 reversed makes in nonactive state the output OUT1 to be shorted to ground and in active state to be cut off The OUT1 terminal serves the function of a power supply output with 3 15A F2 fuse The control panel monitors the F2 fuse condition and signals its trouble The following parameters can be programmed for the output e alarm signaling time FS 47 e burglary alarm signaling delay FS 46 The output is designed to signal the burglary and fire alarms The installer can select the identical signaling mode for the fire alarm and for the burglary alarm FS 9 however the signaling delay if any will only apply to the burglary alarm The installer can activate the signaling of arming disarming and alarm clearing on the OUT1 output FS 9 4 Alarm Control Panel CA 5 SATEL The OUT1output can be assigned to selected control panel zone
34. to the first telephone line deactivates the type 10 output and repeats the whole cycle of dialing the station numbers OUT2 programmed as Telephone line switch CA 5 CONTROL PANEL O O OOOO O O O OO S6666 AC AC OUT1 OUT2 OUT3 AUX KPD DTACLK COM Z1 Z2 COM Z3 Z4 COM Z5 TIP RING T 1 R 1 TELEPHONE Figure 12 Connection of two telephone lines to the control STARTING THE CONTROL PANEL After all electrical connections are made and their correctness checked you can proceed to start the system It is recommended to begin the work with the control panel with no signaling devices connected These can be connected after programming parameters is completed and operation of the realized security system tested After the power is switched on the keypad will report readiness for work with four short beeps followed by a long one If the panel starts alarming the ALARM LED is on and the keypad makes a continuous sound it usually means that a tamper alarm has been triggered by incompatibility of factory settings with parameters of the connected detectors To clear the alarm enter the MASTER access code 1234 and press Then enter the factory service code 12345 and accept it with the key the control panel will enter the service mode The PROGRAM LED will come on and will be lit up continuously and the keypad will start emitting a short beep every 3 seconds At this moment you can proceed to programming the control
35. urpose a one high current alarm output OUT1 protection 3 15A a two OC type programmable outputs OUT2 OUT3 current carrying capacity 50mA designed for direct control of the functioning of relays Pulse type power supply of 1 2A capacity fitted with overloading and short circuit protection 2 power supply outputs for detectors and keypad with a protection of 400mA Built in telephone communicator for a sending information to a monitoring station using one of the two telephone numbers 2 remote programming from a computer fitted with modem Built in RS 232 TTL link enabling the control panel to be directly programmed from the computer Operation by 6 users 6 access codes including that of the Master Service access code which enables the system parameters control panel program ming to be changed and some of the user functions called up Operating the control panel from remote independent keypads which offer the following features a real time status display for all of the control panel armed zones 2 a number of system arming procedures full silent with no exit bypassing a capability to control the locks lighting and other equipment a capability to activate the PANIC FIRE and HELP alarms a functional check of the mains and emergency power supply Electronic control systems a battery condition with optional isolation of discharged battery a fuses and wiring condition and keypad presence a presence