1. Power input Port UP LINK from network switch or midspan or option DC power supply Power consumption less than SW without PD loading Input PSE SW3GI11CN PSE SW3G42CN PSE SW3G44DN 12V 0 190A 0 190A 0 190A 24V 0 104A 0 104A 0 104A 48V 0 061A 0 061A 0 061A 56V 0 056A 0 056A 0 056A Power efficiency 80 at full load 48V typical Operating temperature 20 C 70 C Operation humidity 90 relative humidity non condensing Storage temperature 40 C 85 C Dimension 40mm H x118mm W x90mm D available for DIN RAIL Mounted 14 MSTRONIC CO LTD
2. 802 3af operation The input voltage must be in the range of 50 to 57 VDC if running for 802 3at operation If the PSE SW3G44DN is not powered in above designated input voltage it will only functioning as an Ethernet switch without PoE output For PSE SW3G42CN The input voltage must be in the range of 36 to 57 VDC if input from rear terminal the input voltage must be in the range of 42 to 57VDC if it from port 3 PoE input If the PSE SW3G42CN is not powered in above designated input voltage it will only functioning as an Ethernet switch without PoE output For full load operation make sure your power supply may offer 60W for 2x 24V 1A PoE ports MSTRONIC CO LTD User s Manual MSE PSE SW3 series Input Voltage REAR Model Input Voltage UP LINK Output voltage 802 3af at Isolated 12 57VDC PSE SW3G11CN 12 57VDC No input 12 57VDC As input voltage non regulated 12 57VDC 12 57VDC As input voltage non regulated 12 57VDC Higher voltage output REAR or UPLINK 36 57VDC PSE SW3G42CN 36 57VDC 24VDC regulated 42 57VDC 24VDC regulated 42 57VDC 24VDC regulated 42 57VDC PSE SW3G44DN 42 57VDC 42 57VDC As input voltage non regulated Yes 42 57VDC 42 57VDC As input voltage non regulated Yes 42 57VDC Higher voltage output REAR
3. Powered via 2 data pairs 1 2 3 6 or 4 5 7 8 Blanking are all acceptable Off No power is detected on this port Power wiring The PoE switch family includes 3 models be used for 2 different ranges of input voltage as full range voltage 12 to 57VDC P N PSE SW3GI11CN A8VDC typical 42 to 57VDC P N PSE SW3G44DN amp PSE SW3G42CN 48VDC typical switches allow powered by another PoE source 42 57VDC on port UP LINK For PoE operation make sure your power supply may offer at least 40W for 2x 802 3af PoE port or 80W for 4x 802 3at PoE port If powered on rear terminal please make sure the input current don t over 10A if powered on port UP LINK make sure the input current don t over 2Amp The port 1 amp 2 will deliver DC power over the Ethernet cable the connection as Data pair A on line and 2 Data pair B on line 3 and 6 Data pair C plus V on line 4 and 5 Data pair D plus V on line 7 and 8 MSTRONIC CO LTD User s Manual MSE PSE SW3 series The port UP LINK may get DC power over the Ethernet cable the connection as Data pair A plus V V on line 1 and 2 Data pair B plus V V on line 3 and 6 Data pair C plus V V on line 4 and 5 Data pair D plus V V on line 7 and 8 The terminal block on rear panel should be wiring as FG Vin Vint E Frame Ground DC supply For PSE SW3G44DN The input voltage must be in the range of 44 to 57 VDC if running for
4. for descriptions of each LED indicator If a port LED is off go back and check for connectivity problems between that port and the network device connected 10 MSTRONIC CO LTD User s Manual MSE PSE SW3 series Network Application The PoE Switch can receive power from PoE midspan and provide power to the PD which follows the IEEE 802 3af at standard in the network The PoE Switch can be installed in a more appropriate position for better performance to extend Ethernet to 200 meters The following figure is an example of a network application for PoE Switch PSE SW3G PoE Switch K Ce Network Wireless LAN Network VoIP Phone Camera Access Point Camera MSTRONIC CO LTD User s Manual 3 Model Information MSE PSE SW3 series Input Voltage Input Voltage Model Output voltage 802 3af at Isolated REAR UP LINK 12 57VDC PSE SW3G11CN 12 57VDC 12 57VDC No No non regulated 24VDC PSE SW3G42CN 36 57VDC 42 57VDC No No regulated 42 57VDC PSE SW3G44DN 42 S7VDC 42 S7VDC Yes No non regulated AC DC Adapter Option MS A150 18 MS A150 24 MS A150 48 Maximum output 18VDC 7 5A 24VDC 6 25A 48VDC 3 125A Related model PSE SW3G11CN PSE SW3G11CN PSE SW3G11CN PSE SW3G42CN PSE SW3G44DN MSTRONIC CO LTD 12 User s Manual MSE PSE SW3 series 4 Technical Specifications Standards Ports Transmission speed Swi
5. functions of each LED indicator Front panel detail MSTRONIC CO LTD User s Manual MSE PSE SW3 series POWER LED LED STATUS Description Power Green LED ON when power input DC IN on rear panel or port UP LINK on front panel has valid power supplied Red The indicator only been used on PSE SW3G11CN LED ON when the following warning condition happened Power input under voltage Vin lt 10V Power input over voltage Vin gt 59V PoE over current 2A per port the indicator is unused on PSE SW3G44DN and PSE SW3G42CN Off No power supplied SWITCH LED the right indicator on RJ45 LED STATUS Description P1 P2 amp UP LINK Green A network device is detected 1000Mbps Link Act but no communication activity is detected Green This port is transmitting to or receiving Blinking package from another device at 1000Mbps Yellow A network device is detected 10Mbps or 100Mbps but no communication activity is detected Yellow This port is transmitting to or receiving Blinking package from another device at 1OMbps or 100Mbps Off No device is detected MSTRONIC CO LTD User s Manual MSE PSE SW3 series PoE LED the left indicator on RJ45 P1 P2 Yellow A valid Powered Device PD is detected PoE and delivering power on this port Off No PD is detected on this port Yellow Powered via all 4 data pairs UP LINK PoE Yellow
6. MSE PSE SW3G 3 Port PoE Switch amp Extender Repeat Ethernet and PoE USER S MANUAL MSTRONIC CO LTD User s Manual MSE PSE SW3 series 1 General Information eseeeekRSSEEEKSSRREEEEEEEERRREEEEEEEEEREREE EEN 3 2 Hardware DeSCription cccccsssessssceesesesssneneeeeensesseneeees 3 LED INGIC LTE 3 Power VV UN EEN 5 Ethernet Port MNHA nate te Ah thE ALAN tei as 8 isd BA e ln Le EG 10 NOT WONKA DPIC ANON EE 11 3 Model Iptortattebt ugeet eege 12 4 Technical Specification csccscsseseeseesseesseseesseesesees 13 2 MSTRONIC CO LTD User s Manual MSE PSE SW3 series 1 General Information The PoE Power Over Ethernet Switch family provide two 10M 100M 1000M TX ports with PoE PSE function plus one 10M 100M 1000M TX up link port with PoE PD function It allow powered from PoE power souring equipment PSE and deliver power to PoE powered device PD which is compliant with IEEE802 3af and IEEE802 3at standard to receiver and deliver both of Ethernet data and DC power through the traditional UTP or STP cable The PoE Switch can extend Ethernet data and DC power up to 200 meters This manual will help you install and maintain the PoE switch Installation of the PoE switch is very easy and you will begin to operate as soon as you are powered up 2 Hardware Description LED Indicator There are 8 LEDs on the PoE switch to indicate the status of power and signal The following section describes the
7. d device The Link Act LED green or yellow will light up when the cable is correctly connected Refer to the LED Indicator section for descriptions of each LED indicator If a port LED is off go back and check for connectivity problems between that port and the network device connected The maximum cable length for 10 100 1000BaseT with Cat 5 twisted pair cables is typically 100m 328 ft MSTRONIC CO LTD User s Manual PD Port Wiring MSE PSE SW3 series Port 1 amp 2 provide PoE inject function with maximum 35W ability to power up the powered device use the straight through or cross over Ethernet cable The PoE switch follows the IEEE802 3af Alternative B mode connector assignment The following table shows pin assignment of alternative A and B for the Power Source Equipment Alternative A Alternative A Alternative B Conductor MDI X MDI All 1 Negative Vport Positive Vport 2 Negative Vport Positive Vport 3 Positive Vport Negative port 4 Positive Vport 5 Positive Vport 6 Positive Vport Negativen Vport 7 Negative Vport 8 Negative Vport Be sure the twisted pair cable is bound with the standard RJ 45 pin especially the pin 4 5 7 and 8 If the RJ 45 is bound with the wrong pin number PoE switch will not recognize the PD and won t deliver DC power to PD The yellow PoE LED will light up when the cable is correctly connected Refer to the LED Indicator section
8. or UPLINK Yes MSTRONIC CO LTD User s Manual MSE PSE SW3 series Ethernet Port Wiring The PoE switch family supports one RJ 45 uplink port UP LINK with PoE PD and two RJ 45 ports port 1 amp 2 with PoE PSE with automatic MDI MDI X crossover auto sense the speed and duplex for 10Base T 100Base TX or 1000Base T connection Automatic MDI MDI X crossover allows you to connect to other devices switches hubs or workstations etc without regard to using straight through or crossover cabling Port 1 amp 2 provides Power over Ethernet function that delivers DC power through the data pairs C amp D pair 4 5 and pair7 8 to the PD Port UP LINK provides Power Device function that receive power from 4 pairs or 2 pairs Ethernet cable The following tables describe the wiring diagram of straight through and crossover cabling That crossover cables simply cross connect the transmit lines at each end to the receive lines at the opposite end Straight through Cabling Pin 1 Pin 1 Pin 2 Pin 2 Pin 3 Pin 3 Pin 6 Pin 6 Pin 4 Pin 4 Pin 5 Pin 5 Pin 7 Pin 7 Pin 8 Pin 8 MSTRONIC CO LTD User s Manual MSE PSE SW3 series Cross over Cabling Pin 1 Pin 3 Pin 2 Pin 6 Pin 3 Pin 1 Pin 6 Pin 2 Pin 4 Pin 7 Pin 5 Pin 8 Pin 7 Pin 4 Pin 8 Pin 8 Connect an Ethernet cable into any switch port and connect the other side to your attache
9. tch technology Protocols Flow control Data transmission rate Address table Connect PoE port Maximum PoE power PSE disconnect mode MSTRONIC CO LTD IEEE802 3 IEEE802 3u standards IEEE802 3ab 10 base T 100base TX 1000base T 3 ports with PoE 2 PSE amp 1 PD support auto crossover amp auto polarity 1000Mbps 1000base T 100 Mbps 100base TX 10 Mbps 10base T Auto negotiation store and forward CSMA CD TEEE802 3x full duplex back pressure half duplex 1488000pps for1000base T 148800pps for 100base T 14880pps for 10base T 1K MAC address table self learning RJ 45 Port 1 amp 2 PSE auto power management Pin assignment data pair A 1 2 data pair B 3 6 data pair C plus V 4 5 data pair D plus V 7 8 Port 3 UPLINK 4 pairs PD PSE SW3G42CN PSE SW3G44DN Port 1 amp 2 PSE SW3G44DN IEEE802 3af 16 8W TEEE802 3at 35W PSE SW3G11CN Current limited 2A PSE SW3G42CN 24V 1A Port 3 UPLINK 90W 802 3at 2 event classification DC disconnect 13 User s Manual MSE PSE SW3 series PoE auto detection TEEE802 3af amp IEEE802 3at 2 event classification signaling PoE protection Over temperature over current over under voltage LEDs Link Activity Green ON Green Blinking 1000Mbps Yellow Yellow Blinking 10M 100Mbps PoE Yellow port 1 amp 2 ON PD detect Port 3 ON 4 pair power Blinking 2 pair power POWER Green normal Red alarm

Download Pdf Manuals

image

Related Search

Related Contents

Philips T980 User's Manual  Planar Systems SL3250  KULINARISK Micro-ondas comb c/ar forçado  model 605 / 606 - North Star Engineered Products  SIMNRA User's Guide - Max-Planck  Exodus User Manual  DVD Player  Philips eSATA cable SWN2175  Philips MIS-F, 200, 100 User's Manual  USER MANUAL - Kramer Electronics  