1. Blood B Ketone Test Strips Control Solutions Data Management System ART20287_Rev A Man indd 3 4 Downloaded from www Manualslib com manuals search engine Setting Up the Meter Enter Setup Mode Start with the meter off no test strip inserted df Jp Press and hold until of and J appear This indicates the beeper is turned on X del X and JJ indicate the beeper is turned off Beeper Press J or gt to change the beeper setting Press Q to save the beeper setting and move to set time 11 17 10 3 01 PM Time Date Format p ma The hour flashes Press J or P until the correct hour appears Press Q to save in 5 The date format flashes Press lt Q or P to change the date format Press to the hour and to move to set minutes save the date format and to move to the measurement units Month Da The minutes flash Press lt or P until the correct minutes appear Press to y save the minutes and to move to set date mn i 5 tu Day Month Date 2 o g The year flashes Press J or gt until the correct year appears Press Q to save the IMPORTANT Please check that the correct time and date is set before year and to move to set month z Hs Year f you use the meter for the first time This will help you keep records of amp The month flashes Press or gt until the correct month appears Press to when you monitor and will help you and your healthcare professional amp in save the month and
2. ART20287_Rev A Cvr indd 1 2 Abbott Diabetes Care 666 Doncaster Road Doncaster 3108 Victoria Australia ABN 95000 180 389 1800 801 478 Abbott Laboratories M Sdn Bhd Abbott Diabetes Care No 22 Jalan Pemaju U1 15 HICOM Glenmarie Ind Park 40150 Shah Alam Selangor Malaysia 03 5569 1919 Abbott Laboratories N Z Ltd Ground Floor Bldg D 4 Pacific Rise Mount Wellington P O Box 22 801 Otahuhu Auckland New Zealand 0800 106 100 Abbott Laboratories Pakistan Ltd Abbott Diabetes Care Opposite Radio Pakistan Transmission Hyderabad Road Landhi Karachi Pakistan 021 35100321 Abbott Laboratories Singapore Pte Ltd Abbott Diabetes Care 1 Maritime Square 12 09 Harbour Front Centre Singapore 099253 1800 272 2881 IVD FreeStyle and other brand marks are trademarks of Abbott Diabetes Care Inc National Phytopharma Joint Stock Company 24 Nguyen Thi Nghia District 1 Ho Chi Minh City Vietnam 08 910 6640 ext 849 Abbott Laboratories Abbott Diabetes Care 102 E De Los Santos Ave Madison Street 1554 Mandaluyong Metro Manila Philippines 02 7028577 02 7028578 Abbott Diabetes Care Ltd Range Road Witney Oxon 0X29 0YL UK in various jurisdictions 2010 Abbott ART20287 Rev A 11 10 Downloaded from www Manualslib com manuals search engine User s Manual Cc Abbott 11 1710 2 40 PM Definition of Symbols These symbols are associated with your m
3. 45 ART20287_Rev A Man indd 45 11 17 10 3 01 PM Downloaded from www Manualslib com manuals search engine
4. Blood B Ketone Results sai Downloaded from www Manualslib com manuals search engine MediSense or Optium Glucose and Ketone Control Solutions Important Control Solution Testing Notes Performing a Control Solution Test Managing Your Results Viewing Test Results in Memory Viewing Blood Glucose Averages Transferring Results to a Computer Error Messages E 1 to E 9 What It Means What To Do Troubleshooting eisi a EA 36 Maintaining the Meter Replacing the Battery Cleaning the Meter Storing the Meter Specifications 3 55 cscs austepokueendaaad tae oacamsr Pensa nanaseeatadaaneaeGe 42 RePGPON COS 53 5505 625 tis seisuit ss nananngeceSdolanamhaneatiaadiadadebepadgacanaarind 45 11 1710 3 01 PM amp Intended Use outside the body only in vitro diagnostic use for self testing or professional use in the management of diabetes Use for measuring blood glucose from samples taken from the forearm upper arm base of the thumb or fingers Test blood glucose in fresh whole blood samples Test blood B Ketone 8 hydroxybutyrate in fresh whole blood samples from fingers only IMPORTANT Use only FreeStyle Optium blood glucose test strips and FreeStyle Optium blood B Ketone test strips Other test strips may produce inaccurate results ART20287_Rev A Man indd 1 2 Downloaded from www Manualslib com manuals search engine IMPORTANT See test strip instructions for use for more informatio
5. a logbook Turn Off the Meter Use the opened foil packet to remove the used test strip This turns off the meter Discard the used test strip correctly Note You can also press and hold for at least 2 seconds to turn off the meter The meter also turns off after 60 seconds of inactivity 20 11 1710 3 01 PM amp Understanding Blood B Ketone Test Results High Blood B Ketone Results The meter displays results in mmol L The unit of measurement is preset You cannot change this setting IMPORTANT The meter displays results from 0 0 8 0 mmol L Consult your healthcare professional before changing your diabetes medication programme amp Blood B Ketone is expected to be below 0 6 mmol L High blood B Ketone may be caused by illness fasting vigorous exercise or uncontrolled blood glucose levels Repeat a blood B Ketone test using a new blood B Ketone test strip when e HI appears on the display e Your result is unusually high e You question your result e Your blood B Ketone result is 0 0 mmol L but your blood glucose is higher than 16 7 mmol L 300 mg dL 21 ART20287_Rev A Man indd 21 22 Downloaded from www Manualslib com manuals search engine Meter Contact your healthcare professional for Result is between 0 6 1 5 mmol L and your blood glucose result is Higher than 16 7 mmol L Higher than 300 mg dL Result remains 0 6 1 5 mmol L or becomes Higher than 1 5 mmol L Hi A
6. appear next 25 ART20287_Rev A Man indd 25 26 Downloaded from www Manualslib com manuals search engine The Apply Sample symbols and fl also appear Press T to mark the test as a control solution test and a will appear if performing a B Ketone control solution The appears The meter is now ready for you to apply control solution to the test strip IMPORTANT The test result will be saved to memory as a blood glucose or blood B Ketone result if not marked as a control solution test This may affect your blood glucose averages Apply Control Solution to the Test Strip Shake the control solution bottle to mix the solution Apply a drop of control solution to the white area at the end of the test strip in the area shown The control solution is drawn into the test strip Hold the control solution drop to the white area until the meter beeps if sound is on and the status bar appears on the display This indicates the test strip has obtained enough control solution 26 11 1710 3 01 PM amp o The countdown appears on the display as the meter checks the glucose or n B Ketone level m Note Do not remove the test strip from the meter or disturb the test strip during the H countdown U inne 05 If the countdown does not start remove and discard the used test strip turn off GOB es the meter and try again with a new strip SD mmol View the Result The meter beeps if sound is on when
7. enter test mode a test strip contact Customer Service E No coding required 1 Check that you are using the correct test strip for amp or this meter See test strip instructions for use to Test strip may be damaged verify your strip is compatible with this meter used or the meter doesnot 2 Repeat the test using a test strip for use with No battery is installed 1 Install battery with facing up ete our meter ae i recognise it y Battery is installed incorrectl 9 3 If the error reappears contact Customer Service o y E A Meter error 1 Turn off the meter Dead battery 1 Replace battery Reset date and time if 2 Repeat the previous testing steps necessary or 3 If the error reappears contact Customer Service 35 36 ART20287_Rev A Man indd 35 36 amp 11 1710 3 01 PM Downloaded from www Manualslib com manuals search engine Ue Blood sample is too small 1 See test strip instructions for use for iy Defective meter or test strip 1 Remove the used strip and discard it not start after re application instructions not start after correctly applying the 2 If the countdown still does not start remove applying the Repeat the test using a new test strip blood sample the used strip and discard it correctly blood sample 3 Repeat the test using a new test strip 4 Ifthe test still does not start contact Customer Service 3 If the test still does not start contact Customer Service Sample applied af
8. is turned on Do not use the meter if the display check screen does not exactly match the example Contact Customer Service See Testing Your Blood Glucose section for more information 29 ART20287_Rev A Man indd 29 30 Downloaded from www Manualslib com manuals search engine lL sH 349 12 10 DDB ae 5 Your most recent result with time and date if set it was obtained appears next The following symbols indicate the type of result Blood glucose result Blood B Ketone result lt lt Glucose control solution result ody Ketone control solution result Press to review the previous result Repeat this for each result you wish to review Note To exit meter memory at any time press and hold Appear on the display when there are no previous results to view Press gt to return to a previously reviewed result Repeat this for each result you wish to review Note To exit meter memory at any time press and hold 30 11 1710 3 01 PM amp Viewing Blood Glucose Averages While in memory press Q Your 7 day average appears Note n number of results included in your 7 14 or 30 day average IMPORTANT Set the date and time before testing to be able to review averages Averages do not include glucose and B Ketone control solution results blood B Ketone results and results that do not show time and date Control solution
9. removing it from its foil packet e Use each test strip only once Downloaded from www Manualslib com manuals search engine j m Do not use expired test strips they may produce inaccurate results a The expiry date is the last day of the month if only the month and year E g Expiry date are shown March 31 2012 Do not use a wet bent scratched or damaged test strip Do not use the test strip if its foil packet has a puncture or tear in it Note See test strip instructions for use for operating range and more information on limitations of use Test Site IMPORTANT Wash your hands and the test site with warm soapy water to ensure accurate results Thoroughly dry your hands and the amp X test site To warm the site apply a warm dry pad or rub vigorously for a few seconds Note Avoid areas near bones areas with lots of hair and squeezing the puncture site Bruising may occur at alternate sites but will disappear quickly If bruising occurs consider selecting another site Finger tip testing is different to alternative site testing Adjust the lancing device accordingly for testing site See lancing device instructions for use for more information Fingertips 11 1740 3 01 PM Alternative Sites Performing a Blood Glucose Test Obtaining a blood sample from alternative sites forearm upper arm and base of Open the foil test strip packet at the notch and tear down to remove the the thumb is
10. results not marked as control solution tests may cause averages to be inaccurate lt appear on the display when there are no current averages to view LO blood glucose test results appear in averages as 1 1 mmol L 20 mg dL H blood glucose test results appear in averages as 27 8 mmol L 500 mg dL Press to view the 14 day average Press to view the 30 day average Press to return to the 7 day average or Press 1 to return to the memory screen Press and hold Q to turn off the meter The meter turns off after 30 seconds of inactivity 31 32 ART20287_Rev A Man indd 31 32 amp 11 1710 3 01 PM Downloaded from www Manualslib com manuals search engine 33 Transferring Results to a Computer Transferring test results to a computer requires a compatible data management system For more information please go to our website or contact Customer Service Error Messages a E Ese The temperature is too hot or too cold for the meter to work correctly Meter error ART20287_Rev A Man indd 33 34 Move the meter and test strips to a location where the temperature is within the test strip operating range See test strip instructions for use for the appropriate range Wait for the meter and test strips to adjust to the new temperature Repeat the test using a new test strip If the error reappears contact Customer Service Turn off the meter Repeat the previous testing ste
11. the result appears on the display The test is complete examples shown The result is stored in memory as a control solution gue a Ti result or you can write it in a logbook as a control result appears with the result if performing a B Ketone control solution test 27 ART20287_Rev A Man indd 27 28 amp Downloaded from www Manualslib com manuals search engine Compare the control solution result to the range printed on the blood glucose or blood B Ketone test strip instructions for use The result should fall within the range Causes of out of range results include e The meter and test strips may not be working correctly Repeat the test with a new test strip Follow the testing instructions carefully Contact Customer Service if the result is still outside the printed range Turn Off the Meter Use the opened foil packet to remove the used test strip This turns off the meter Discard the used test strip correctly Note You can also press and hold for at least 2 seconds to turn off the meter The meter also turns off after 60 seconds of inactivity 28 11 1710 3 01 PM amp WEE Tiree Ol Cr icy Meter memory stores up to 450 events control solution blood glucose and blood Ketone results and other meter information The most recent events appear first Viewing Test Results in Memory Start with the meter off no test strip inserted Press to turn the meter on This display always appears when the meter
12. use Check your ketones When you have an illness When your blood glucose is above 16 7 mmol L 300 mg dL When you are experiencing unusual blood glucose results When you and your healthcare professional feel it is necessary 15 16 ART20287_Rev A Man indd 15 16 amp 11 1710 3 01 PM Downloaded from www Manualslib com manuals search engine Test Site IMPORTANT Wash your hands with warm soapy water to ensure accurate results Thoroughly dry your hands To warm the site apply a warm dry pad or rub vigorously for a few seconds Note Avoid squeezing the puncture site Fingertips Use only fingertip blood samples for blood B Ketone testing Performing a Blood B Ketone Test i Open the foil test strip packet at the notch and tear down to remove nl the test strip Insert the Test Strip With the contact bars 3 black lines facing up insert the test strip into the meter until it stops This turns on the meter Note The meter turns off after 3 minutes of inactivity Remove and reinsert the unused test strip to restart the meter 17 ART20287_Rev A Man indd 17 18 Downloaded from www Manualslib com manuals search engine 130 i25 This display always appears when the meter is turned on Do not use the meter if the display check screen does not exactly match the example Contact Customer Service See Testing Your Blood Glucose section for more information Time and date if set
13. 1 Schade DS Eaton RP Metabolic and clinical significance of ketosis Special Topics in Endocrinology and Metabolism 1982 4 1 27 2 Wiggam MI O Kane MJ Harper R Atkinson AB Hadden DR Trimble ER Bell PM Treatment of diabetic ketoacidosis using normalization of blood 3 hydroxybutyrate concentration as the endpoint of emergency management Diabetes Care 1997 20 1347 1352 3 Harano Y Kosugi K Hyosu T Suzuki M Hidaka H Kashiwagi A Uno S Shigeta Y Ketone bodies as markers for Type 1 insulin dependent diabetes and their value in the monitoring of diabetes control Diabetologia 1984 26 343 348 4 Ubukata E Diurnal variation of blood ketone bodies in insulin dependent diabetes mellitus and non insulin dependent diabetes mellitus patients The relationship to serum C peptide immunoreactivity and free insulin Ann Nutr Metab 1990 34 333 342 5 Luzi L Barrett EJ Groop LC Ferrannini E DeFronzo RA Metabolic effects of low dose insulin therapy on glucose metabolism in diabetic ketoacidosis Diabetes 1988 37 1470 1477 6 Hale PJ Crase J Nattrass M Metabolic effects of bicarbonate in the treatment of diabetic ketoacidosis Br Med J 1984 289 1035 1038 7 Directive 1999 45 EC of the European Parliament and of the Council of 31 May 1999 concerning the approximation of the laws regulations and administrative provisions of the Member States relating to the classification packaging and labelling of dangerous preparations
14. 1710 3 01 PM amp 43 Test strips Control solution Assay Method Assay Range Blood glucose Blood B Ketone Control Solution Range Blood glucose Blood B Ketone Functions Blood glucose testing Blood B Ketone testing Memory Glucose averaging Control solution marking and testing ART20287_Rev A Man indd 43 44 See test strip instructions for use See control solution instructions for use Amperometric electrochemistry See blood glucose test strip instructions for use See blood B Ketone test strip instructions for use See blood glucose test strip instructions for use See blood B Ketone test strip instructions for use 450 events 7 14 and 30 day Downloaded from www Manualslib com manuals search engine Beeper Display Light Data Port Operating Range Meter temperature System temperature Meter relative humidity System relative humidity System altitude On When countdown starts and ends On Stays on during countdown turns off 30 seconds after results appear Stays on while transferring results to a computer Yes 10 to 50 C 50 to 122 F See operating range of the test strip you are using See test strip instructions for use 10 to 90 non condensing 10 to 90 non condensing Clinical testing demonstrates that altitudes up to 2 195 metres 7 200 feet above sea level do not affect results 44 11 1710 3 01 PM amp References
15. al immediately Check blood B Ketone if checking ketones is part of your diabetes management programme 14 11 1710 3 01 PM amp Meter Tes Your Blood B Ketone Important Testing Notes H Severe high blood glucose Repeat the test with a new test strip If the Pepearenenrecuicicaa hod result is HI contact your healthcare professional tam Use the meter within the test strip operating range Higher than There may be a problem immediately Eee mee e Use the test strip immediately after removing it from the foil packet 27 8 mmol L with the test strip Check blood B Ketone if checking ketones is part E g Expiry date Use each test strip only once Higher than of your diabetes management programme March 31 2012 500 mg dL Do not use expired test strips they may produce inaccurate results The expiry date is the last day of the month if only the month and ear are shown Note If you see the error messages E 3 or E 4 consult y the Error Messages section in this user s manual Do not put urine on the test strip amp Do not use a wet bent scratched or damaged test strip amp a Do not use the test strip if its foil packet has a puncture or tear in it IMPORTANT Contact your healthcare professional if you have symptoms that do not match your test result and you have followed Note See test strip instructions for use for operating range and more information on the instructions in this user s manual limitations of
16. appear next f HE and the Apply Sample symbols O appear indicating the meter is ready for you to apply a sample to the test strip Obtain a Blood Sample Select a test site Use the lancing device to obtain a blood sample See lancing device instructions for use for more information 18 11 1740 3 01 PM amp Apply Blood to the Test Strip Bring the blood drop to the white area at the end of the test strip The blood is drawn into the test strip IMPORTANT If the countdown does not start you may not have applied enough blood to the test strip See test strip instructions for use for re application instructions If the countdown still does not start remove the used strip and discard it correctly Start a new test with a new test strip Hold the blood drop to the white area until the meter beeps if sound is on and the status bar appears on the display This indicates the test strip obtained enough blood The countdown appears on the display as the meter checks your B Ketone level Note Do not remove the test strip from the meter or disturb the test strip during the countdown 19 ART20287_Rev A Man indd 19 20 Downloaded from www Manualslib com manuals search engine ca m Li DB mmol L B25 View the Result The meter beeps if sound is on when the result and appears on the display The test is complete example shown The result is stored in memory or you can write it in
17. eter The European Battery Directive requires separate LOT Batch code collection of spent batteries aiming to facilitate recycling and to protect the environment The batteries in this product should be removed and Catalogue number disposed in accordance with local regulations for separate collection of spent batteries Caution This packaging is capable of being recycled Consult instructions for use Manufacturer Do not drink Temperature limitation Do not reuse Use by In vitro diagnostic medical device Date of manufacture STERILE R Sterilised using irradiation lancets only ansi Ee Serial number ART20287_Rev A Man indd 1 11 17 10 3 01 PM Downloaded from www Manualslib com manuals search engine Table of Contents ART20287_Rev A Man indd 23 Intended Use w Monitoring System Kit Contents 0 ccc cece cece eee eens Setting Up the Meter Enter Setup Mode Beeper Time Date Time Format Date Format Measurement Units AnuuubDS Testing Your Blood Glucose Important Testing Notes Test Site Alternative Sites Performing a Blood Glucose Test Understanding Blood Glucose Test Results 13 Low and High Blood Glucose Results 13 Testing Your Blood B Ketone 16 Important Testing Notes 16 Test Site i sscns races 17 Performing a Blood B Ketone Test Bas F a Understanding Blood B Ketone Test Results a21 High
18. eter may prompt you to reset the time and date See Setting Up the Meter in this user s manual Note Test results will be not be lost even if the meter loses its time and date settings Press and hold to turn the meter on If the meter does not turn on check to 40 11 17 10 3 01 PM amp Cleaning the Meter Avoid getting dirt dust blood control solution or liquid in the meter test strip port Clean the outside of the meter using a damp cloth and mild soap Healthcare Professionals Acceptable cleaning solutions include 70 isopropyl alcohol or A mixture of 1 part ammonia 9 parts water or A mixture of 1 part household bleach 9 parts water IMPORTANT Do not try to clean the test strip port amp Do not pour liquid into the test strip port or onto the buttons Do not immerse the meter in water or other liquid 41 ART20287_Rev A Man indd 41 42 Downloaded from www Manualslib com manuals search engine Storing the Meter Store the meter in the carrying case provided Specifica Size Length Width Weight Power Source Battery Life Memory Storage Temperature Meter 7 47 cm Top 5 33 cm Bottom 4 32 cm Depth 1 63 cm 40 to 46 grams 1 CR 2032 Lithium coin cell battery Approximately 1 000 tests Up to 450 events including control solution blood glucose and blood B Ketone results and other meter information 25 to 55 C 13 to 131 F 42 11
19. n about sample types Potential infection risk Healthcare professionals performing blood tests with this system on multiple patients must always wear gloves and should follow the infection control policies and procedures approved by their facility Read the instructions in this user s manual Failure to follow instructions will cause incorrect results Practise the testing procedures before using the meter Follow your healthcare professional s advice when testing blood glucose levels and blood B Ketone levels Observe caution when using around children Small parts may constitute a choking hazard How Your FreeStyle Optium Blood Glucose Monitoring System Works When you insert a test strip into your meter the Apply Sample message shows on your meter s di window When a blood sample or control solution sample is applied to the test strip the glucose isplay or B Ketone reacts with the chemicals on the test strip This reaction produces a small electrical current that is measured The result shows on your meter s display window IMPORTANT Avoid getting dust dirt blood control solution water or any other substance in the meter s test strip port 11 1710 3 01 PM amp Monitoring System Kit Contents Monitoring System Kit contains e Meter e User s Manual Carrying Case Logbook e Warranty Card Your Kit may also contain Blood Glucose Test Strips e Lancets e Lancing Device Items not included
20. ppears when result is Higher than 8 0 mmol L High blood B Ketone A problem requiring medical assistance may be occurring You may be at risk of developing diabetic ketoacidosis DKA Very high blood B Ketone or There may be a problem with the test strip sick day management instructions Contact your healthcare professional immediately Repeat the test with a new test strip If the result is HI contact your healthcare professional immediately 22 11 1740 3 01 PM K2 ense or Optium Glucose and Ketone Control Solutions Important Control Solution Testing Notes Use only MediSense or Optium Glucose and Ketone control solutions with the meter Replace the cap securely on the bottle immediately after use IMPORTANT When you open a control solution bottle for the first time count forward 90 days and Cults this date on the control Do not use control solution past the expiry date solution bottle using a pen that won t smear or wipe off Throw D Aa atl E away any remaining solution after this date to ehscrele NYE or ou Grills Miele conte So uton Do not swallow or inject the control solution Control solutions may be used with either glucose or B Ketone test strips Do not use the control solution as eye drops Use control solution To practise testing without using your own blood IMPORTANT Control solution results should fall within the control solution range printed on the test strip instruction
21. ps If the error reappears contact Customer Service Downloaded from www Manualslib com manuals search engine a EH Esa The blood glucose level may be too low to be read by the system or There may be a problem with the test strip The blood glucose level may be too high to be read by the system or There may be a problem with the test strip Blood was applied to the test strip too soon p Review the testing instructions Repeat the test using a new test strip If the error reappears contact your healthcare professional immediately Repeat the test using a new test strip If the error reappears contact your healthcare professional immediately Review the testing instructions Repeat the test using a new test strip If the error reappears contact Customer Service 34 11 1710 3 01 PM amp Message __Whatit Means What To Do Troubleshooting E 5 Meter error 1 Check that you are using the correct strip for this meter See test strip instructions for use to verify your strip is compatible with this meter 2 Repeat the test using a test strip for use with The meter Test strip is not inserted 1 With the contact bars 3 black lines facing your meter Gh 55 correctly or fully into the up insert the test strip into the meter until it 3 If the error reappears contact Customer Service test mode meter stops This turns on the meter after inserting 2 Ifthe meter still does not
22. s for use Check that the lot number printed on the test strip packet and instructions for e When you are unsure of your blood glucose or blood B Ketone test results is a po RR Aa Si To confirm that the meter and test strips work together correctly Contact Customer Service for information on how to obtain control solutions e Repeat the test if control solution results are outside this range Stop using the meter if control solution results are continually outside the range printed on the test strip instructions for use Contact Customer Service IMPORTANT Control solution results do not reflect your blood glucose or blood Ketone level 23 24 ART20287_Rev A Man indd 23 24 amp 11 1710 3 01 PM Downloaded from www Manualslib com manuals search engine Performing a Control Solution Test Open the foil test strip packet at the notch and tear down to remove the test strip Insert the Test Strip With the contact bars 3 black lines facing up insert the test strip into the meter until it stops This turns on the meter Note The meter turns off after 3 minutes of inactivity Remove and reinsert the unused test strip to restart the meter This display always appears when the meter is turned on Do not use the meter if the display check screen does not exactly match the example Contact Customer Service See Testing Your Blood Glucose section for more information BBBm 88 88 0 40 2 5 Time and date if set
23. subject to limitation Contact your healthcare professional before test strip beginning alternative site testing pul e Alternative site results may differ from fingertip results when blood glucose ob levels change rapidly e g after eating a meal or taking insulin or during or after exercise 5 Use alternative sites before or more than two hours after you eat a meal take Insert the Test Strip insulin or exercise With the contact bars 3 black lines facing up insert the test strip into the meter A 1 ane until it stops This turns on the meter D bood les fi i Lae her Pa Note The meter turns off after 3 minutes of inactivity Remove and reinsert the unused o not E loo eae s rom a E wi ae test strip to restart the meter D Urea You think your blood glucose is low or changing rapidly amp You have been diagnosed with hypoglycaemic unawareness Alternative site results do not match the way you feel e You are within two hours of eating a meal taking insulin or exercising Tro C 7 This display always appears when the meter is turned on Forearm Do not use the meter if the display check screen does not exactly match the l example Contact Customer Service il E See Testing Your Blood Glucose section for more information 56 58 88 08 0 30 2 5 Time and date if set appear next 9 10 ART20287_Rev A Man indd 9 10 amp 11 1710 3 01 PM Downloaded from www Manualslib com manuals search engine The Apply Sample s
24. ter meter 1 Remove the used strip and discard it turns off correctly 2 Review the testing instructions 3 Repeat the test using a new test strip 4 Ifthe test still does not start contact Customer Service 37 38 ART20287_Rev A Man indd 37 38 11 1710 3 01 PM Downloaded from www Manualslib com manuals search engine Maintaining the Meter Replacing the Battery The meter comes with a CR 2032 lithium coin cell battery installed It provides power for about 1 000 tests E Appears on the display when the battery is low e Causes the display light to fail to turn on D H When appears you may still use the meter and the results will be accurate The display light will not work Replace the battery immediately amp 94g 1026 When appears alone the meter is not usable The meter turns off automatically Replace the battery immediately 1 Gently push the battery cover in and up to remove it 39 ART20287_Rev A Man indd 39 40 Downloaded from www Manualslib com manuals search engine If the meter includes a plastic tab pull on the tab to remove the battery If the meter does not include a plastic tab push the battery upward to remove it Insert a new CR 2032 lithium coin cell battery facing up Slide the battery cover into place until it clicks Note Dispose of used batteries correctly see that the battery was installed correctly If meter turns on the m
25. the used test strip This turns off the meter Discard the used test strip correctly Note You can also press and hold Q for at least 2 seconds to turn off the meter The meter also turns off after 60 seconds of inactivity 12 11 1710 3 01 PM amp Understanding Blood Glucose Test Results Low and High Blood Glucose Results The meter displays results in mmol L or mg dL The unit of measurement is preset You cannot change this setting IMPORTANT The meter displays results from 1 1 27 8 mmol L 20 500 mg dL Low or high blood glucose results can indicate a potentially serious medical condition General Lower than 2 8 mmol L Low hypoglycaemic Repeat the test with a new test strip even Lower than 50 mg dL if you do not feel that you have low blood glucose Higher than 16 7 mmol L High hyperglycaemic Repeat the test with a new test strip even Higher than 300 mg dL if you do not feel that you have high blood glucose 13 ART20287_Rev A Man indd 13 14 Downloaded from www Manualslib com manuals search engine Meter iN LU Appears when result is Lower than 1 1 mmol L Lower than 20 mg dL Appears with result which is Higher than or equal to 16 7 mmol L Higher than or equal to 300 mg dL Severe low blood glucose or There may be a problem with the test strip Blood glucose level is high Repeat the test with a new test strip If the result is LO contact your healthcare profession
26. to move to set day make informed decisions about your care You must set the time and tu The day flashes Press lt Q or gt until the correct day appears Press A to save the date to review averages Month Day day and to move to set time format Measurement Units Time Format mmol L The unit of measurement set by the factory appears You cannot change this mg dL setting Contact Customer Service for more information a an 7 Note Ifusing the 12 hour time format AM and PM appear Press to return to set beeper or press and hold Q to turn off the meter The time format flashes Press lt or P gt to change the time format Press to save the time format and to move to set date format 24 Hour Format ART20287_Rev A Man indd 5 6 amp 11 1710 3 01 PM Downloaded from www Manualslib com manuals search engine Important Testing Notes This display always appears when the meter is turned on cat SD rro ASi You should check that your meter matches the example you AA see here exactly every time your meter turns on v M Do not use the meter if the display check screen does not exactly match the example X If the screen does not match the meter may show an incorrect result Please contact Customer Service ARAA ABAR T Ase exe mawa E g Expiry date March 31 2012 ART20287_Rev A Man indd 7 8 Use the meter within the test strip operating range e Use the test strip immediately after
27. ymbols and Fl appear next indicating the meter is ready for you to apply a sample to the test strip Obtain a Blood Sample Select a test site Use the lancing device to obtain a blood sample See lancing device instructions for use for more information amp A Ji Apply Blood to the Test Strip Bring the blood drop to the white area at the end of the test strip The blood is drawn into the test strip P IMPORTANT If the countdown does not start you may not have applied enough blood to the test strip See test strip instructions for use for re application instructions If the countdown still does not start remove the used strip and discard it correctly Start a new test with a new test strip 11 ART20287_Rev A Man indd 11 12 Downloaded from www Manualslib com manuals search engine mmol L ou 949 2 10 Hold the blood drop to the white area until the meter beeps if sound is on and the status bar appears on the display This indicates the test strip has obtained enough blood The countdown appears on the display as the meter checks your glucose level Note Do not remove the test strip from the meter or disturb the test strip during the countdown View the Result The meter beeps if sound is on when the result appears on the display The test is complete example shown The result is stored in memory or you can write it in a logbook Turn Off the Meter Use the opened foil packet to remove