Home

© 2014 Koninklijke Philips N.V. All rights reserved

image

Contents

1. reset Red LED on remote will Start blinking Luminaire will turn OFF and then turn back ON to indicate reset Frequently asked questions My luminaire group is at low light level and does not respond to SpaceWise remote buttons Luminaire may in open group state close the group by referring to instructions in step 4c My luminaires are not turning off at night Ensure the luminaire group is in locked operational state Refer to instructions in step 4e to lock the luminaire group Some luminaires do not react with rest of the group on off command Luminaires are not properly grouped with the rest of group Reset the luminaire by following the instructions in step 7 Then re group the luminaire by referring to instructions in step 4 My luminaires do not turn on If luminaires are in manual on mode they may have been turned off by accessory wall switch Try turning on using the switch Luminaires can also be accidentally turned off by remote in unlocked state Refer to instruction in step 4e to lock the group Technical Support For technical support on this product contact Philips Lighting Electronics N A 10275 W Higgins Road Rosemont IL 60018 Customer care Please refer to the contact number printed on the specification sheet of the purchased luminaire
2. group and remote will press daylight daylight start blinking While the remote is Red LED on blinking select remote will stop blinking A V Then press send This will move the e light output setting End of step by one step Lock the group refer to step 4e After locking lighting group is operational at selected light level Note that the default setting is Medium To get to high go one step up To get to Minimum go two steps down Medium Will move light output setting from default to High of 88 to 100 Medium Will move light output setting from default to Low of 88 to 77 Low to Will move light output setting from default Minimum of 77 to 66 If unsure about light output selection step up to the highest setting and observe the subtle reduction in light level each time you activate lower settings 7 Trouble Shooting A Factory reset will restore the luminaire to its default state and all the group configuration settings will be deleted Reset operation can be used to bring any wrongly configured luminaire back to its original factory reset condition Unlock the group refer to step 5a Group will be unlocked for further operation 10 Philips Lighting Controls Point to any of the luminaires in the group and press reset Once LED stops blinking with remote still pointing to any one of the luminaires in the group and press send
3. PHILIPS 2014 Koninklijke Philips NV All rights reserved Philips reserves the right to make changes in specifications and or to discontinue any product at any without notice or obligation and will not be liable for any co from the use of this publication philips com luminaires 03 15 12NC 443580099050 Print 30194 Philips Lighting North America Corporation 200 Franklin Square Drive Somerset NJ 08873 Tel 855 486 2216 lit PHILIPS Lighting Controls f al SpaceWise d 4 Quick start ouide Wireless lighting control solutions from Philips Getting Starteo Installation and configuration of luminaires with SpaceWise technology Fixtures must be installed by a qualified electrician in accordance with all national and local electrical and construction codes and regulations 1 Confirm all components received Luminaires Poe SpaceWise d j remote Instructions Luminaire installation instructions In luminaire box Accessory installation In accessory box Additional information can be found at www philips com spacewise SpaceWise User Manual SpaceWise Design Guide 2 Philips Lighting Controls Determine luminaire orientation L TI Ensure sensor is facing away from window Ensure sensors from adjacent luminaires are not positioned next to one another Install luminaires per manufacturer installation instructio
4. d off c All the luminaires in the group will go to 50 light level All the luminaires in the group will turn ON and OFF together If any luminaires in the group do not turn ON OFF they are not part of the group Go back to step 4a to add the luminaires back in to the group Lock the group 4e 6 Point to any of the luminaires A in the group and press lock N Wait for LED to EUR stop blinking 0 apx 10 seconds then press send Philips Lighting Controls Il RedLEDon 4 O remote will Start blinking The luminaire will FLASH twice and group will turn OFF and ON once for Daylight calibration Group is ready for normal operation 5 Choose an application mode Choose the desired application mode per group Behavior varies for each application See the SpaceWise Design Guide for more details Application ON OFF behavior Mode Open Office Auto ON Auto OFF 24 Open Office Manual ON Auto OFF 25 Private Office Meeting room Auto ON Auto OFF 1 Private Office Meeting room Manual ON Auto OFF 3 Corridors and Stairwells Auto ON Auto OFF 26 Unlock the group Da Point to any of the luminaires in the group and press unlock N Wait for LED to stop blinking apx 10 seconds then press send Red LED on remote will start blinking Red LED on 0 remote will stop blinking O The luminaire will FLASH twice and group light le
5. ns Plan luminaire wireless groups When configuring open plan offices with the SpaceWise Remote large groups of 30 50 luminaires are recommended to maintain the lighting aesthetics of the space Smaller groups may turn off more frequently than desired SpaceWise remote 4 OG 30 C CG 60 F Qo group O O O pO NO A link mode test 100h PHILIPS Philips Lighting Controls 4a Ab Create a group Grouping is required to initiate system functionality and dimming behaviors The Luminaire s have to be in a factory new state to group them AN together If changes were previously made on the luminaires then perform a factory reset as per the instructions in step 7 before proceeding Open Group Point remote to Luminaire will dim any luminaire down to 5 and press Open once N Make sure the button is pressed only once Pushing multiple times can create multiple networks which can cause undesired operation Add luminaires to group Walk to the next Added luminaire will luminaire to be dim down to 5 added to the group point to the luminaire and press add Repeat step for adding all the luminaires in the group Close group 4c Point to any of the luminaires added in the group and press close c Ad Verify the group Point to any of the luminaires in the group and press on an
6. vel will go to 50 5b Set application mode 8 Point to any of the luminaires in the group and press mode While the LED is still mode Il RedLEDon 4 O remote will start blinking blinking red enter the number for the preferred mode see list at step 5 Point to any of O The luminaire will the luminaires FLASH twice and in the group group light level will press send Lock the group refer step 4e After locking lightin go to 50 to 8 group is operational in selected mode If unsure about mode selection or remote blinking status then wait for the remote blinking to stop and redo step 5b 6 Change maximum light Choice of max light output per group output will be influenced by existing conditions such as partition height reflectances light level preference and energy goals Light output setting Max light output options High 100 Medium Default 88 Low 77 Minimum 66 Philips Lighting Controls 6a Set light output per group Unlock the group refer to step 5a Group will be unlocked for further operation To select light output settings use the up and down arrows to change between high medium low and minimum Light level can be altered one step at a time The daylight button must be pressed to initiate a new change after every end of step For each step up or down Point to any luminaire Red LED on 2 in the

Download Pdf Manuals

image

Related Search

Related Contents

Télécharger - SodaStream – Espace presse  Possible-4  Descarga Manual de Instrucciones  Tiago Cruz - Repositório Institucional da Universidade Católica  Samsung SGH-E300 Manual de Usuario  TELEVISOR A LCD MANUAL DE SERVICIO  「KA 808」取扱説明書  鷹グC 取扱説明書  Automation for gates and doors  RayBio® Human Follistatin ELISA Kit  