Home

SYSTEM 816 PROGRAMMING GUIDE Chapter 1 Summarize

image

Contents

1. lt 100mA lt 1 5W lt 650mA 12V DC12V 15V 315MHZ 10 55 C 40 70 2 5 kgs 255mm X 235mm X 70mm 159mm X 138mm X 33mm Page 2 of 16 SYSTEM 816 PROGRAMMING GUIDE Chapter 2 Installation and Connection 2 1 Wiring Diagram 2 1 1 Wiring diagram on main board System 816 Wiring Diagram 0000 O Status Light Record Chip Wireless Receiver Module JP1 DIRECT CONNECT Reset Note Wired 8 zone expand 00 port can be expanded The 2 7K EOL RESISTOR from 8 wired zones to end of circuit iai 00 AUX Vol 14VDC ees 00 AUX Max output current 1000mA GND Earth Line End 1 BEI f 1 73 if 75 CND 26 A bod AC ALL Nt a Ay ey ei KEY N DTA J PN A A A ed N ii QM 8 SATAY W IEL I Te EL lal ana tt mi Extemal 12VDC z Cea a sealed 16 5vAC gt j a Bee lead acid a Speaker Montor z re L VD i eypad il pi 220VAC 14VDC Output T J Telephone f indicator LED will light on when working normally Z1 Z8 means 1 8 zone 2 1 2 Wiring diagram of expand board 9 16 Wired Zone Expand Wiring Diagram Plug In Zone Expand Port Of Main Board CGOUOD O00000 OQOO00O0 010 0100 Z9 GND 210 211 GND 212 213 GND Z144 Z15 GND Z16 0009090009000909 09 Page 3 of 16 SYSTEM 816 PROGRAMMING GUIDE Z9 Z16 means 9 16 zone 2 1 3 8 zones Expand module Z9 Z16 means 9 16 zone It must connect 2 7K resistors connecting is the same with Z21 Z8 Set expanded 9 16 wired zones O
2. ARM Zone Light 3 Emergency Key 4 Number Key Shortcut Key F ARM F2 Home ARM F3 Pause F4 Confirm Key Page 7 of 16 SYSTEM 816 PROGRAMMING GUIDE Specification 1 Function Indicator Light Power Supply Communication Signal Status ARM Setting Indicate the working status of the System Function Displa Explanation Indicator Light ii AC Power Supply Normal P A ual AC Power Supply Break on Dialing and Sending message Status the line is busy FF The line is not in use a Signal from Wireless Detector Received Communication OFF Normal Status o A Normal Status ON Keypad Work Normal on OFF Keypad Failure _ _ _ _ _ _ _ ono ARM Zone Light 1 2 3 14 15 16 Display the Zone Status Display Oo Explanation o SO ON ARM Activated Training Status ready to Train wireless detector Zone Indicate the Zone disarm after Alarm but the alarm status hasn t been stopped Slow Flash Wired Zone bad connection the Circuit is Open or Short 1 Second Zones in Effect on ARM Status 8 Emergency Key A B C 24 hours Alarm Status can be defined as Fire Alarm Robbery Alarm Emergency Call No indicator no sound If telephone preset it will dial the number when alarm the communication light will on 4 Number Key 1 2 3 4 5 6 7 8 9 0 For password and program set use Shortcut Key F1 F2 F3 F4 Easy to operation with One Key
3. F4 Factory setting 0 8 lines output corresponding requirement 00 means siren following 01 16 is corresponding Zone alarm output 17 means Zone alarm output 18 means press emergency A key 19 means ARM 20 means DIS ARM 21 means ARM with output and DIS ARM without output Remote control of module output approach state approach 1 8 expresses 1 8 roads state 1 opens output 2 closes the output for example in the state by remote control 1 1 That opens the first output 1 O expression being closed down or opens the first output 4 36 Record Search Operating press 99 2 F4 into the searching emergence Record method X X 3 0 KHK K OK OX 3K number days things Chour minute Things 01 16 is fire regions alarm 30 is alarm set 40 is alarm deserved Under the searching emergence press F3 to find the next one Page 16 of 16
4. Set successfully the buzzer will sound a long Di the Indicator LED will light on 3 Exit Operation Or exit automatically after 30 seconds 4 Status Exit successfully the buzzer will sound a long Di the indicator LED will light off Or exit automatically after 30 seconds the buzzer will not sound indicator LED off The following 4 5 4 35 for all operations must be set up in the state setting success of the buzzer blew out setting is not successful would be short Di three times to be set up after the setting from the state in order to carry out normal operations 4 5 Change Installer Password Format 30 New Installer Password 6 bites F4 Confirm Key 4 6 Wireless Detector Training Function 1 Format 20 zone number 2 bites F4 Confirm Key Zone number is from 01 16 Corresponding zone LED will light on 2 Set Code Press remote controller or activate the detector to send signal to alarm panel The signal LED will light up when the alarm panel received the signal and saved to the specified zone indicating the alarm panel the signal Press F4 Confirm Key the corresponding zone LED light off MEANS The host memory to the address of the wireless signal THEN THE detector was triggered will host the reception to identify the corresponding address of the wireless signal the corresponding report to the police standoff 4 7 Delete Wireless Detectors Format 21 zone number 2 bits F4 Confirm Key Zo
5. 00MM copper core wire from the keypad to alarm panel is up to 150 meters 4 keypads can be connected in series Note After the programming being in progress to the host is finished please spring with lead plane JP1 place to keep the jumper wire cap down batch away to prevent others from carrying out operation on your host and enhance the security of the host 1 3 Features High speed digital communication compatible ADEMCO4 2 CID digital communication protocol Send alarm signal to alarm center With eight way output module can be customized output Linkage output remote control output mainly USED IN linked with the monitoring control home appliances Lamp exactly see 4 35 Different programmable settings such as alarm sounds zone types recording monitoring remote controlling telephone number phone line Check and etc Page lof 15 SYSTEM 816 PROGRAMMING GUIDE Compatible with wired and wireless function 1 group 6 bits primary passwords 15 groups subsidiary setting passwords are available to improve security 6 groups of phone number and 3 group alarm center phone number could be set When the alarm activated it could repeat dialing the numbers 8ARM modes exit ARM boundary ARM single zone ARM delay ARM remote ARM compel ARM remote ARM and preset time ARM 6 DISARM modes single zone DISARM keypad password DISARM long distance DISARM time DISARM remote setting DISARM DISARM when
6. F1 EXIT ARM F2 Boundary ARM Only when boundary Zones Preset F3 Detector Low Vol Quirt Pause F4 Confirm Key Buzzer Sound In this operation different buzzer sound indicates different meaning Long Sound Remote Control or Keypad operation received Long Sound 1 Sound Zone Alarm minute Short Sound __ Sound per press the Keypad Short Sound 3 Invalid Input or Remote Control Operation times Short Sound Delay ARM Started or Delay Zone Activated the sound will end till per 3 seconds the delay time is over Page 8 of 16 SYSTEM 816 PROGRAMMING GUIDE 3 4 ARM ARM means the system is in arm condition and ready to response the alarm signal by detectors in corresponding defence zone If arm successfully the buzzer send a long beep the light in corresponding zone is on for 1 sencond and the ARM indication light is on If arm failed the buzzer send three short beep and ARM indication light is off and user should check if any defence zone is triggered or in open circuit condition or the system is in ARM condition If there is an ARM Delay the system will exit the delay after inputs ARM dictate and short sound every second till delay time is over It will not send alarm before some zone is activated 3 4 1 Leaving Taking ARM All Zones except Side Road or Screened Zones start Alarm Status if any zone activated the system will take relevant reaction dial the alarm center preset telephone number or local polic
7. MIK the POSITIVE should be connected to MIK and the negative should be connected to ground wire GND 2 Installation of Keypad 2 1 Opening of the keypad use a screwdriver to open the plastic hole of the back cover upside of the keypad 2 7 2 Connection of the keypad SEE PICTURE use a copper core wire to Keypad Wri Ng DIA gram connect the keypad with connector of alarm panel The wire from the keypad to TEMPER alarm panel is up to 150 meters 4 keypads can be connected in series to avoid destroy of keypad the anti temper port could be connected to the terminal of alarm panel Connect to related terminal on main board Address umpper 2 3 Keypad address no address jumper means NO 1 keypad insert address jumper 1 means NO 2 keypad insert address jumper 2 means NO 3 keypad insert address jumper 3 means NO 4 keypad 2 4 Close the cover when the connection is finished 2 8 Installation when wireless zones only If you want to use the wireless zones only connect the wired zones with the ground wire GND by 2 7K resistors in short connection keep close of the wired zones Note Make sure the all the connections are correct before power up the alarm panel Avoiding any opposite connection short connection of power line siren line and detector power line avoiding short connection of detector power line and signal line Page 6 of 16 SYSTEM 816 PROGRAMMING GUIDE Chapter 3 System
8. lines telephone format Format 77 line number 50 56 F4 line number correspond 50 56 33 6 Format Format O 1 2 is center O CID 1 available program 4 2 5 user s telephone 6 Protection telephone 7 Removal telephone Format after reset 0 is 0 1 6 line is 5 4 16 Set Report Output Format 33 0 1 ARM or DIS ARM 0 1 program 0 1 low battery 0 1 main panel start F4 1 open 0 close Factory Setting 1 34 0 1 AC power cut off 0 1 AC power recovery 0 1 save 0 1 save F4 Factory setting is 1 Status O No Output 1 Output Factory Setting 1 Output 4 17 Set ABC Key Format 67 0 1 F4 Confirm Key 0 means close ABC key 1 means start ABC key Factory setting is 1 4 18 Remote Control On Off Format 71 status F4 Confirm Key Status 0 Remote Control Off 1 Remote Control On Factory Setting 0 Off Page 14 of 16 SYSTEM 816 PROGRAMMING GUIDE 4 19 Set Remote Control Ring Time Format 72 Time F4 Confirm Key Time 1 9 times Factory Setting 8times 4 20 Remote Telephone no password Option Format 74 status F4 Confirm Key Status 0 need user password 1 no need user password factory setting is O 4 21 Choose Alarm Receiver Control Format 75 status F4 Confirm Key status 0 Press 1 to receive Alarm sound 1 Receive Alarm sound after 5 seconds or press 1 4 22 Set Telephone Line Check
9. 3 46 hour 2bits minute 2 bits F4 3 Preset time disarm Set Mode see4 3 47 hour 2bits minute 2 bits F4 Page 15 of 16 1 alarm 1 sound dis alarm 2 sounds 0 no sound reset won t SYSTEM 816 PROGRAMMING GUIDE 4 28 Set Time modify Coefficient Format 48 Coefficient 00 99 F4 Status reset coefficient is 50 make coefficient up if time is too quick more than 50 make coefficient down if time is too slow less than 50 Note That the time coefficient is adjusted the system time and the current time of the second deviation difference between the coefficient of each interval 1 150S 4 29 Set Alarm if AC power down Format Press 62 0 1 F4 1 sound 0 no sound 4 30 Set Open Close of Anti Jumper alarm function Format Press 63 0 1 F4 1 open 0 close Factory Setting 0 4 31 Set Keypad wire break inspection Format Press 64 0 1 F4 1 open 0 close Factory Setting 0 4 32 Set Center Precision Format Press 65 precision value 1 bite F4 value O 9 Factory Setting 6 4 33 Set Center Signal Time Format Press 66 Signal time 1 bite F4 time 0 9 Factory Setting 6 4 34 Set Dial Rounds Format Press 69 dial rounds 1 9 F4 Factory Setting 9 4 35 Set Output Module Format 8 lines output time 35 Line Number 1 8 Seconds 4 bites F4 Seconds 0000 9999 seconds Factory setting 60 seconds 8 lines output requirement 36 Line Number 1 8 Requirement 1 2 bites Requirement 2 2 bites
10. ARM press 2 to disarm stop dial the following phone number after ARM started press 3 to start Remote Monitor press 8 to Return end monitor press 7 change recorded sound press 8 exit press 4 start siren press 5 exit siren and return to control status Note Remote Control Status is different from the 1 2 3 of Hang on operation Page 10 of 16 SYSTEM 816 PROGRAMMING GUIDE 3 8 Record Record the alarm sound by another preset phone or mobile phone Differentiate to receive the police sound recording and the dialling mark sound recording 3 8 1 After receiving the warning sound recording while receiving the warning sound used by the state of long range 7 to amend the methods for recording audio 7 by telephone or cell phone microphone to record the contents of the need to tell 10 20 seconds 8 from the recording according to the 6 player has a good voice recording hang up to determine the correct For re recorded after playing according to the 7 was recorded the operation can be repeated until satisfied with this 3 8 2 dial up record 3 8 2 The dialling mark sound recording 1 Keypad Input Installer password Factory Setting 666666 F4 Confirm Key Start Set Status 71 1 F4 Start Remote Control Status 72 2 F4 Set Ring time as 2 times Exit Set Status 2 Record Use another preset phone or mobile phone dial the number of alarm system after connect
11. Factory Setting is 8 times after connected Input User Password after a long sound Di Access to Remote Control Status 3 6 1 Remote ARM Disarm In remote control status input 1 to start ARM Status if succeed you will hear a long sound Di if not succeed you will hear 3 short sound input 2 to disarm if Succeed you will hear a long sound Di if not succeed you will hear 3 short sound 3 6 2 Remote Monitor In remote control status press 3 then you can hear the instant sound from the zones press 8 to return 3 6 3 Remote control to siren In remote control status press 4 start siren press 5 exit siren 3 Set Receive Alarm by Telephone when the alarm connected the phone or mobile phone user can remote control the system by phone or mobile phone There are 3 methods as following 3 7 1 Dial up then pick up alarm Press 3 start directly Remote Control Status 3 7 2 It can also be programmed as See 4 21 after connected say Hello to receive recorded sound after twice record and indicate sound Du input user password to remote control status or program to automatically say Hello after indicate sound Du after enter the user password see4 20 directly Remote Control Status 3 3 Dial up then pick up alarm press 2 hang up Host stop dial up Remote Control Status Start control status by using telephone or mobile phone press 1 to start
12. N OFF 1 Insert the expand module Factory setting inserted 2 Start setting mode see 4 3 3 Format 79 status F4 Confirm key Status 0 9 16 zones OFF 1 9 16 zones ON Factory setting 0 4 Exit see 4 4 Note The reduction can not return to the factory necessary to manually set 2 1 4 8 way output module that GON SWOD SON NC4 COM4 NO4 90N 99W09 99N Wiring Block pI oo a n LON LWOO LON NC2 COM2 NO2 80N 809 89N NC1 COMI NOI i _ Power DATA CND nett O Lamp i BUS Power Wiring Block Together 8 way output module with the keyboard connect to the keyboard port It can customize the output ROADS and OUTPUT methods Exactly see 4 35 Linkage widely used in monitoring control of home appliances and other Page 4 of 16 SYSTEM 816 PROGRAMMING GUIDE fields 2 2 Connection of Power supply 2 2 1 Connection of transformer input AC220V 2 red wires connecting directly Transformer AC16 5V 2 black wires output terminal will connect AC terminal AC1 and AC2 2 2 2 DC12V storage battery connection The black wire should be connected to negative of battery 2 3 Connection of Wired Detector 2 3 1 Connection of signal wires of wired detector N C CONNECTING N O CONNECTING There are two connection way to avoid destroy Detector SignalEnd Detector Signal End cutoff or short connection see picture 1 NORMALLY CLOSED Connecting a 2 7K EOL resistor in series to the
13. On Off Format 78 Status F4 Confirm Key status 0 No Check 1 Check Alarm when the line was cut Check 4 23 Set Programmable4 2 Code for different Alarm Center Factory Setting 0 No Format 8 01 16 alarm code 2 bites F4 Set Zone number 1 16 8 17 set alarm code 2 bites F4 8 18 set alarm code 2 bites F4 8 19 set alarm code 2 bites F4 8 20 set alarm code 2 bites F4 8 21 set alarm code 2 bites F4 8 22 set alarm code 2 bites F4 8 23 set alarm code 2 bites F4 8 24 set alarm code 2 bites F4 8 25 set alarm code 2 bites F4 8 26 set alarm code 2 bites F4 8 2 7 set alarm code 2 bites F4 Set Alarm Code Set Dis alarm Code Set A key Code SetB key Code SetB key Code Set Self inspection Code Set Programmed Code Set System Startup Code Set AC power recovery Code Set AC power break Code Set Low Battery Code 4 24 Set interval time of Self inspection Report Format Press 41 time 2 bites F4 confirm key Time 00 99 hours 00 means cancel report of Self inspection 4 25 Set Alarm Sound time Format Press 42 time 2 bites F4 confirm key Time 00 40 Alarm time 00 40 x 30 second Factory setting 02 means 02 x 30 60seconds 4 26 Set Siren Sound of Alarm and Dis Alarm Format Press 61 0 1 F4 change setting 4 27 Preset Time Arm Disarm Setting 1 Preset time arm Set Mode see4 3 45 hour 2bits minute 2 bits F4 2 Preset time disarms Set Mode see4
14. Operation 3 1 System Operation The main usage of the alarm system is to prevent illegal intruder from your home or office or to get help in emergency When you are leaving your office or home make sure all the windows and doors are locked Set ARM by remote controller or keypad of alarm panel the system will be in guard status If any alarm zone is activated the following circs will happen 3 1 1 If host has siren linked and the defence zone is in sound alarm condition there will be hooter from siren and beep from keypad on spot 3 1 2 Alarm panel will send the alarm to control center by dialing the telephone if set to send the alarm to control center 3 1 3 If telephone number is set it will dial the preset numbers in turn after switching to a telephone receiving alarm control see 3 7 operation 3 1 4 Zone LED will keep light on in alarm status till eliminate its alarmmemory 3 2 Operation of Remote Controller Remote Controller DIS ALARM DIS ALARM Status Set ARM Leaving taking ARM f BOUNDARY Home ARM BOUNDARY Zone Alarm Status Emergency Emergency when a Hijack or emergency call DIS ALARM Fast press twice Key of the Remote Controller Note BOUNDARY ARM will be in effect only when BOUNDARY Zone was set 3 3 Keypad Panel and Indicator LED Light ime Saw 129939 45 6 7 B AM Oo 9 1011 12 13 14 15 16 Communication Sonal Sel Parts Name 1 Function Indicator Light 2
15. SYSTEM 816 PROGRAMMING GUIDE Thanks for choosing System 816 Multi Function Alarm Control Panel We suggest you reading carefully this guide operating this system strictly on the standard procedure System 816 is suitable for most circumstances and convenient for using no matter its appearance function or operation We hope this Guide could answer most of your questions when using the system Chapter 1 Summarize 1 1 Summarize System 816 takes advanced microprocessor as its core technology So it has the advantages of high integration very good stability flexible function and convenient use 1 2 Attentions before usage Get approval from local police office before presetting the police phone number as the alarm phone number Ensure the system is in the correct installation then connect AC power supply with the panel Only suitable for DC 12V 7AH sealed lead rechargeable storage battery be cautious to connect red positive line with positive terminal and black negative line with negative terminal The incorrect connection will cause damage of main panel Rechargeable current lt 1 5A Avoid metal parts or hand contact to the electronic parts on the circuit when install the lines Must use 2 7K resistor short unused wired zone Mark wires to avoid miss connection when using too many wired zones Cut off all AC power supply battery and telephone line before maintenance Short JP1 when reset main panel The 1
16. UIDE 4 11 Set User Code Alarm Center Code Format 31 4bites User code F4 Confirm Key Delete User Code 32 F4 Confirm Key Alarm allocate 4 bites network code FOR THE alarm center Note Don t use this operation if without network 4 12 Set ARM Delay Time Format 40 Time F4 Confirm Key Time O0O0 255 seconds 4 13 Set ALARM Time Format 43 Time F4 Confirm Key Time O0O0 255 seconds 4 14 Set Telephone Number 1 Central number establishment Format 50 Telephone Number F4 Confirm Key Don t use this operation if without network Delete telephone number in alarm center 50 F4 Confirm Key 2 user alarm telephone number establishment Format 5 Phone number of group 1bites Telephone F4 Confirm Key Phone number of group 1 6 express 1 6group telephone 3 Users report to the police phone number deleted Format 5 Phone number of group 1bites F4 Confirm Key 4 set the phone number inside to outside Format 5 phone number a few groups one number to machine that is outside to play inside for an additional funding of the phone numbers such as 0 or 9 F3 phone number F4 Phone number of group 1 6 express 1 6group telephone Note Dial according to cycling in proper order when giving an alarm If the host cannot receive confirmation signal to do more than dial up 10 Centre dialing is not affected after withdrawing from a defended position the dialing giving an alarm stops immediately 4 15 7
17. connecting alarm 8zone modes instant zone delay zone 24 hours zone boundary zone fire alarm zone gas zone check zone and BY PASS zone Remote control function external monitor monitoring from long distance Built in voice module 10 20seconds record voice alarm function Set the alarm delay time and siren yelp time Search record of emergency Remote controller can be used to set alarm DIS ALARM emergency alarm and other operation Operate from keypad easily and convenient Phone line malfunction indication function system will alarm when phone line is cut off or short The alarm dialling is in priority Backup DC 12V 7AH sealed lead rechargeable battery support work when AC power cut off Watch dog function to avoid system down Remark Pull out the jumper head in JP1 of the main panel after finishing program for the main panel which can prevent other person operate the main panel and improve security 1 4 Configuration Main configuration Metal box Keypad LED display 1pc User Manual 1pc Accessories bag Wireless receiver parts 1 5 Main specification Power supply Stand by consume current Power Alarm output current Output voltage Wireless receiver frequency Working temperature Working Humidity Weight Metal box size Keypad size 1pc transformer and main board inside 1pc phone line 1 bag terminal resistance 1 pc antenna AC220V 10
18. e Operation Press F4 Key or press on remote controller to set ARM 3 4 2 BOUNDARY ARM also named Home ARM when a BOUNDARY AR M start alarm status non BOUNDARY ARM will not activate alarm 1 Operation Press F2 Shortcut Key or press on Remote Controller to set ARM Boundary arm see4 9 3 4 3 Set Single Zone ARM DIS ARM the specified zone start alarm status the other zones will not activated alarm Operation Set single zone ARM Zone Number 01 16 F Shortcut Key Set single zone DIS ARM Password 6 bites Zone Number 01 16 F4Shortcut Key 3 4 4 Fast alarmed set it can be operated direct without time late Operating press F 1 3 4 5 Set compelled ARM Password F1 Note Boundary ARM and Single Zone ARM can be set at the same time or turn to EXIT ARM if ARM not stopped 3 5 Disarm DIS ALARM Status 1 Operation User Password 6 bites F4 Confirm Key Factory User Password 123456 or press key on Remote Controller 2 Disarm Succeed ARM Indicate Light off if the system refuse the dictate the Buzzer will short sound 3 times or system has already disarm Page 9 of 16 SYSTEM 816 PROGRAMMING GUIDE 3 6 Remote Control When System is set as Remote Controllable See 4 18 Factory Setting non remote control use a preset phone or mobile phone to remote control the alarm system to ARM disarm record or monitor Ring time when dial the preset phone Set in Step 4 19
19. ed input user password Factory Setting 123456 7 Speak what you want to record to telephone or mobile phone the recorded sound will play automatically after 12 seconds or press 8 exit recording press 6 paly the finished recorded sound then hang up If need new record sound press 8 exit then press 7 stat new record sound till it s satisfied 3 Confirm Record Dial the phone or mobile phone after connected press 1 key on the phone or mobile phone to receive sound if need revised please repeat above Step 2 4 After record keypad input installer password Factory setting 666666 F4 Confirm Key Start Set Status 71 0 F4 End Remote Control Status 72 8 F4 Set Ring time as 8 times Exit Set Status 3 9 DIS ALARM Stop the flashing status of alarm indicator LED light stop sending messages to alarm center 1 Operation User password 6bites F4 Confirm Key User Password Factory Setting 123456 Or press key on the remote controller to DIS ALARM 2 If succeed the buzzer will long sound Di the indicator LED light off 3 10 BY PASS Zone Checking Press F1 the zone LED will light on no more than 1 second Page 11 of 16 SYSTEM 816 PROGRAMMING GUIDE Chapter 4 System Settings 4 1 Basic Settings from Factory mine syste 7 Note Function 1 to 12 will resume factory settings after RESET 4 2 Reset 1 Operation 951753082 F4 Confirm Key 2 Status Reset succes
20. ne number is from 01 16 Note If the deleted detectors activated the indicate LED on main board will not light on 4 8 Set Zone Type and Output Alarm Sound 1 Operation Zone number 2 bites Zone type 1 bite Siren status 1 bite F4 Confirm Key Zone number 01 16 indicates 1 16 zone Zone Type 0 Instant Alarm zone 1 Fire Alarm Zone 2 Emergency Zone 3 Delay Alarm zone 4 24 Hours Alarm zone 5 Test Zone at least 2 times alarm in 30 seconds 6 Gas Alarm Zone 7 BY PASS zone 8 Door alarm Zone in ARM status if door is open in DIS ALARM status if door is closed factory setting is Q 1 2 4 6 zone type is 24 hour ARM status not effected by ARM or DIS ARM operation Siren Speaker status 0 alarm without sound 1 sound alarm factory setting is 1 4 9 Set Boundary Arm Format 19 Zone number 2 bites 0 1 0 close 1 open F4 Zone number 01 16 4 10 Door function set Format 60 Zone Number 1 bite 0 1 F4 confirm key zone number 1 8 0 open 1 close Factory setting is 0 when Zone indicate Door ALARM Zone ring function is normal in DIS ARM status defense zone is normal in ARM status Note Eighth of the defense area for the fixed doorbell defense area if the eighth settings standoff for the doorbell when the defense area Will not be withdrawn and security arrangements to prevent the impact of a defended position Page 13 of 16 SYSTEM 816 PROGRAMMING G
21. sfully the buzzer will sound a long Di all the indicator LED will light on for 1 second Note JP1 jumper on the main board must be short connected before this operation 4 3 Change user Password 1 Change Primary password Primary password 6 bites 08 F4 Confirm Key the setting indicate LED on input new primary password 6 bites F4 Confirm Key after the buzzer sound a long Di the indicator LED light off new primary password is in effect Primary password 123456 2 Increase Subsidiary Password Primary password 6 bites 08 F4 Confirm Key the setting indicate LED on input subsidiary password number 2 bites F4 Confirm Key subsidiary password number 01 15 means 15 groups subsidiary password number sequent number the corresponding LED light on Input subsidiary password 4 bites F4 Confirm Key after the buzzer sound a long Di new subsidiary password is in effect 3 Delete subsidiary password Primary password 6 bites 08 F4 subsidiary password number To delete the current sub code number F4 F4 loud buzzer Bell son of a successful password to delete 4 X Exit setting status or automatically exit after 30 seconds Note Subsidiary password available for to be opposite exit ARM boundary ARM Page 12 of 16 SYSTEM 816 PROGRAMMING GUIDE 4 4 Set Mode 1 Operation Installer password 6 bites F4 Confirm Key Factory Installer Password is 666666 2 Status
22. terminal detector of the lt Sie CNI 2 K loop of each zone connecting the other end of the resistor to the signal terminal of wired 7n GND Zn GND detector One of the signal connector should Alam Panel Zone Pore Alam Panel Zone Pore be soldered to the resistor The other end of resistor should be connected to the other signal terminal of detector by corresponding signal wire and then connected to GND port of main board 2 NOMORMALLY OPENED Connecting a 2 7K resistor in parallel connection to the terminal detector of the loop of each zone 2 3 2 Connection of power of Wired Detector connecting the POSITIVE of wired detector to the AUX port connecting the negative to the ground wire GND port 2 3 3 Connecting the unused zones with 2 7K EOL resistor connection otherwise the corresponding indicator light will keep lighting so that the ARM cannot be set Note Mark wires to avoid miss connection when using too many wired zones 2 4 Connection of Siren Speaker Siren Speaker Port The POSITIVE of siren speaker should be connected to BELL end of alarm panel the negative should be connected to the ground wire GND 2 5 Connection of Telephone Line Phone Communication Port The exterior line should be connected to LIN1 LIN2 TEL1 and TEL2 should be connected to the telephone Page 5 of 16 SYSTEM 816 PROGRAMMING GUIDE 2 6 Connection of Sound Monitor Sound Monitor Port The signal line should be connected to