Home
        DT1000, DT2000, & DT8000
         Contents
1.   Place Lane  etc  For example if 4 cars are racing and lane 3  finishes first followed by 4  1  and 2  then the LCD will read    341 2     Pressing RESET or   lt SPACE gt  will clear the LCD and the timer will be ready to time the next race  The DT8000 serial  port transmits the finish order and elapsed times for all cars  The data sent by the serial port is  formatted as 7 bit ASCII characters that can be interpreted by any terminal type program such as  Windows 95   s_    Hyper Terminal     Refer to Section 4 for details on configuring your PC for  communicating with the DT8000  The data sent from the DT8000 to the PC will be similar to the  following  where the data is provided as 1    Place Lane  1  Place Time  2  Place Lane  2    Place  Time etc  The following illustrates the data that might be received if four lanes are in use     DT8000 NewBold Products    12 5455 22 9831 33 7745 43 8224  12 6790 33 1288 23 2092 43 5644    32 8820 13 5109 43 5134 23 6202    3  Installation Procedure    Tools Required To Install   Before you get started with your installation  you will need to gather a few hand tools and related    items required to test and operate the DTX000  The required items are     1  Hand held Drill  amp  3 8 inch drill bit   2  Wire cutters or scissors   3  Light source  typically 1  60 75W Incandescent Bulb for every 3 4  stop sensors    4  Fine Tipped Punch or Nail  optional     The DTX000 timer  start switch  and stop sensors are used on the pinewood derby r
2.  again  the DTX000 will display a single  dash over the    1      designation  Press RESET again to enter the timing mode     The timing starts when the start switch moves and will stop when the car passes over the stop  sensor  The LCD will then display the elapsed time with a resolution of 0 1 ms  Press RESET on  the DTX000 box or the space bar  lt SPACE gt  on your PC to clear the LCD and begin a new race     An example time display on the LCD is   2 5135    Using the Optional Computer Interface   DT1000  DT2000  amp  DT8000     This time is also transmitted by the DTX000 serial port connected to an RS 232 port on a  Personal Computer  PC   The time is sent to the PC using 7 bit ASCII characters that can be  interpreted by any terminal type program such as the    Hyper Terminal    program  part of the  Windows 3 1 95 98 Operating System  Refer to Section 4 for details on configuring your PC for  communicating with the DTX000     The data sent from the DTX000 to the PC is similar to the following   DT8000 shown   DT8000 NewBold Products    2 5315  3 1022    2 9673  lt  Most recent time  Mode 2   DT2000  amp  DT8000 models     The DTX000 times two lanes when in Mode 2     The DTX000 automatically enters this mode when stop sensors are found connected to sensor  inputs  1 and 2 and all other sensor inputs are left open     After turning the power on  the user should press RESET to clear the Self test display  After this  RESET  the LCD will display    2 LANES    to indicate t
3.  however you think is best  We suggest using the supplied cable ties    and cable mounts to attach the cables to the bottom of your track and routing them to the  DTX000 display in a bundle if possible     4  Operation    General   As mentioned in Section 2  at power up the DTX000 will turn on the LED and all segments of the  8 digit LCD  The user should press the    RESET    button to clear this initial state  The DTX000  then determines the number of stop sensors connected to the handheld unit  Once the software  makes this determination an operational mode is set  Once set  this mode cannot be changed  except by powering down  removing or connecting additional sensors and reapplying the  DTX000   s power     If you plan to use the PC interface  you should configure the PC   s terminal program and connect  the DTX000 to the PC prior to applying power to the DTX000  There is no problem with making  this connection after power up  but your PC will miss the initial information sent from the DTX000   Refer to the end of this section for information on how to configure your terminal program     Mode 1 Operation  DT1000  DT2000  amp  DT8000    In Mode 1  the LED will turn on once the Start Switch moves and turns off when the car crosses  the finish line  After the car finishes the DTX000   s LCD will display the elapsed time and the PC if  connected will also display the elapsed time  The LCD will hold this time indefinitely until the user  presses the    RESET    button  After t
4.  to NewBold Products   NewBold Products will repair and return the equipment via Priority Mail or FedEx Ground  Faster  shipping is available at actual cost  Warranty repairs are not applicable for modified or damaged  equipment     90 Day Return Policy    If for any reason  you are not satisfied with your equipment purchase  you may return it within 90  days of purchase for a full refund  excluding shipping charges   Once equipment is received and  inspected we will issue a refund  This return policy does not apply to any modified or damaged  equipment     12    
5. Installation and Operating  Instructions for the    DT1000  DT2000   amp  DT8000    Pinewood Derby  Finish Line and Timer    Software Version 4 0  DT8000   Software Version 2 0  DT1000  amp  DT2000     11 20 05    NewBold Products  Atlanta GA    www newboldproducts com          1  Introduction    Thank you for purchasing the DTX000  Pinewood Derby Timer  Whether you   re a Scout  Royal  Ambassador  Awana  or in another group  we hope you find the DTX000 helpful in developing  your cars and conducting your race events  This manual refers to the    Pinewood Derby     PWD   race event  We realize that many groups have different names for the event  but for simplicity we  will use what seems to be the predominant name  This manual provides information for three  models  DT1000  DT2000  and DT8000  Features specific to a particular model are noted in the  sections that follow     NewBold Products began designing and building PWD timers in 1996  initially a simple one lane  timer  primarily for developing fast cars  That first timer became a marketed product  the DT1000   The DT8000 was our second PWD timer and represents a dramatic increase in product capability  and performance while maintaining the same affordability that became our trademark with the  DT1000  NewBold Products believes that high quality and low cost is possible through using a  standard configuration regardless of the application     Your DTX000 timer will fit any track from 1 to 8 lanes regardless of length or 
6. acetrack as  shown in Figure 1  The incandescent light doesn   t need to be placed too close to the track   probably 3 6 feet above the track is sufficient depending on ambient light conditions     Installing the 9V Battery  To install the 9V battery you will need to remove the back cover from the handheld unit  Remove    the six machine screws that hold the two halves together  Remove the back cover and install the  9V battery into the black battery holder near the bottom of the circuit card  Replace the cover and  install the six machine screws     Using the 9V Wall Adapter  The wall adaptor that NewBold Product sells is a 2 1mm plug  9VDC output adapter with the    center conductor having the Positive polarity  Warning  Using a wall adapter with the  incorrect polarity will damage your timer making it inoperable     Incandescent  i Garter Peg Light Source    Finish TE  Line      w  Sensors N  a  l  Software Options Gable to Cables to   gt  F    Gop Sensors    Hyperemninal    free  Gart Switch      RaceVIEW sills    DeroyMaster            Gart Lever     re  w  Switch                        Serial Cable  DB9F to DB9M    DTX000 Timer  Figure 1  Timer  Switch  and Sensors    Installing the Stop Sensor s   see Figure 2    To begin your installation  decide where you will place the stop sensor s   They should be  located at your track   s finish line normally 32 feet from the starting line and also as close to the  centerline of each lane as possible  Note that not all tracks ar
7. ane to finish as well  or timeout after 9 9999 seconds     After all cars have finished  the DT8000   s LCD will display the finishing order by lane number   The PC if connected will display the finish order and elapsed times for all lanes  The LCD will  hold with this information indefinitely until the user presses the    RESET    button  After the user  presses    RESET    the DT8000 will clear the LCD and wait for the Start Switch to move  This cycle  repeats continuously     Configuring Your PC   s Terminal Program  DT1000  DT2000  amp  DT8000     The DTX000 sends data to your PC at 1200 baud  with 7 data bits  no parity  and 2 stop bits   You should also turn flow control    OFF        If you are using the Windows 95 operating system on your computer you likely have the terminal  program    Hyper Terminal     This program can be found under  lt Start gt    lt Programs gt     lt Accessories gt    lt Hyper Terminal gt   Once you have started this program  go to  lt File gt    lt New  Connection gt   The program will prompt you for a name  you could call the session    DTX000    or  whatever you prefer  After giving a name  you will have a phone number dialog box  From this  dialog box edit the    Connect Using    box to say    Direct to Comx     Where Comx is Com1  Com2   etc  The serial port for many PCs will be Com1  but this varies  After entering your Com port and   lt OK gt   you will see a Comx Properties dialog box  At this box enter the connection properties as  Bi
8. e 32 feet in length  but 32 feet is  probably the most common  Regardless of length  it is important that each sensor be equal  distance from the starting line to avoid errors in timing and finish order     Important  The stop sensor has a polarity  therefore it will only  operate when connected in one way  Connect the sensor to the  handheld unit so that the STRIPED wire or COPPER color wire is on  the TOP wire  the wire closest to the front of the timer should have       the stripe   Cars Sop  Guide Rail Sensor  i      rr         El    l gSensorCable  l    3 8  Diameter  Track   Sde Wew Drilled Hole    re     f le      FF i  j lane A                  t lane B 2 i     4   i  Finish Line  Track   Top Vew    Figure 2     Sensor Installation    The sensor diameter is 0 38     Once you have measured and marked the locations for the stop  sensors  use a fine tipped punch or nail to make a starting indention  This will help keep the drill  bit well centered when you begin to drill  You should consider using a smaller drill bit to make a     pilot    hole  This pilot hole will keep the larger drill bit more precisely on your center mark     If this is going to be a permanent installation you can glue each sensor in place using epoxy  a  hot glue gun or other suitable glue  If you plan to use the DTX000 on multiple tracks you  probably want to make the sensor installation more temporary  using a weak glue or tape  Also  you may not need any glue at all if your sensors fit snugly int
9. f you have very low times such as  0 2000 seconds  this indicates your light source is too low  Move the light source 3 6 inches  closer to the stop sensors and retest  Test using 1 or 2 lanes only  to verify the elapsed time  without using a computer     11    7 4 Timer does not appear to stop  Recommendation  You may have too much light over the  sensor  Back the light off some and try again  See section 7 1 for how to adjust the lighting     7 5 Serial interface not sending data to computer  Recommendations     1  Verify that the cable is well connected to both the timer and PC   2  Confirm that the cable is a    straight through    or 1 1 cable  this means that pin 2 connects  to pin 2  pin 3 to pin 3 etc     3  Make sure that the serial port is configured properly if using Hyperterminal or Procomm  4  Verify that the connector you are using on your PC is really the Comm port you think it is   to test this  disconnect the PC interface cable at the DTX000 end  short pins 2 and 3   together and using Hyperterminal  type information on the keyboard  this info should be   echoed back to your PC   s monitor if you have selected the correct Comm port   5  Verify that your PC is not running any background applications that may be interfering  with the Comm port  such as Palm Desktop applications  Under Win 95 98 the right side  of the task bar shows programs that are resident in memory  some of these may need to  be closed to allow your PC to talk to the Comm port    7 6 DerbyMa
10. g technologies to enhance your race event  Perhaps  one of the most important benefits of using consumer electronics for your display is that most of  these solutions can be implemented at zero cost to your group     These solutions are presented for information only and they do not have to be implemented  exactly as described here  In fact we expect that these ideas will only be a starting point for your  group  Let us know how you implement your display and we ll provide this information in future  manuals     Disclaimer  NewBold Products does not formally endorse any of the following  products  manufacturers or distributors expressly  but we are suggesting a few  possible products as a starting point  These products are available from  reputable dealers and manufacturers and have their own respective warranties  etc     VGA to NTSC Converter    NTSC is the standard video format that TVs use in North America  Converters are widely  available which convert your PC   s VGA signal to an NTSC signal that can then be displayed on  any TV  Several VGA to NTSC converters are mentioned in the following paragraph  By sending  your VGA signal through a converter and to a big screen TV  such as a 27    or larger you can  provide a very large real time display system for your race  You could also split the NTSC signal  and run two TVs  one on each side of your track or one at the starting line  one at the finish line   Total cost   lt   100  using loaned or rented TVs     Potential Sol
11. hat two stop sensors were found  After  pressing RESET again  the LCD will display two dashes in the    1      and    2    locations  After  pressing RESET again  the DTX000 will enter the timing mode     Timing starts when the start switch moves and continues until both cars have crossed the finish  line  passing over the stop sensors      The LCD will first display the winning car   s lane number and the elapsed time for that car  For the  first place car  the lane number will be shown in the far left digit directly above the label that reads  4 Sho  For example if the car in lane 2 finishes first  the LCD display might read   2 2 5135    After displaying the winning lane   and elapsed time  the user should press RESET or  lt SPACE gt   to display the a place lane number and elapsed time  The second place lane number is  displayed on the LCD in the second digit of the display  directly above the label that reads roe  Pressing RESET or  lt SPACE gt  again will clear the LCD and the timer will be ready to time the  next race     Using a Computer to Display Finish Order and Times     If you would like to display and perhaps save the race results  you can see this information by  using the DTX000 serial port  It will display the finish order and elapsed times for both cars     The data sent by the serial port is formatted as 7 bit ASCII characters that can be interpreted by  any terminal type program such as Windows 95   s    Hyper Terminal     Refer to Section 4 of this  manua
12. he microcontroller and the timing    hardware that measures your car   s elapsed time  The frequency stability of this oscillator is      100 ppm  For a measured time of 2 5 seconds  the actual or    true    time may be 2 5     0 00025  seconds  However  the frequency stability is specified over a    10 to  70 C temperature range   Since the DTX000 normally operates over a confined temperature range of 15 to 30 C  the  working frequency stability is much better      20 ppm  This translates to a measurement error of      0 00005  This is very good since it is one half of the DTX000   s time resolution     7  Troubleshooting    7 1 Cars are not stopping timer  Recommendations  Check the lighting  Adjust the lighting  away from the timer  so that the sensors are not found when timer is switched on  Then  move the lighting closer to the track in 6 or 12    increments  continue turning the timer on and  pressing reset to see if all lanes are recognized  Stop moving the light closer once all lanes  are found  Minimize unnecessary ambient lighting if this seems to be a problem  Flash  photography is not a problem with the DTX000     7 2 Stop sensors are not found  Recommendations  verify that enough light is present over the  sensor  60W for every 3 4 lanes   also make sure you are using an incandescent type of  light  Verify that the sensors are plugged into the handheld unit with the correct polarity      copper facing up    7 3 Timing or start stop seem erratic  Recommendation  I
13. he user presses    RESET    the DTX000 will clear the LCD and  wait for the Start Switch to move  This cycle repeats continuously     Mode 2 Operation  DT2000  amp  DT8000     In Mode 2  the LED will turn on once the Start Switch moves and turns off after both cars cross  the finish line for lanes 1 and 2  After both cars have finished  the DTX000   s LCD will display the  winning car   s lane number and the elapsed time for that lane  After the user presses    RESET     the LCD will display the second place car   s lane number and elapsed time  The PC if connected  will display the finish order and elapsed times for both lanes  The LCD will hold with this  information indefinitely until the user presses the    RESET    button  After the user presses     RESET    a second time  the DTX000 will clear the LCD and wait for the Start Switch to move   This cycle repeats continuously     Mode 3 Operation  DT8000 only    In Mode 3  the LED will turn on once the Start Switch moves and turns off after all cars have  crossed the finish line  In this mode  the number of lanes in use can be any number from 3 to 8  and the stop sensors can be connected to any position at the 18 pin header  For example the  user can have 4 lanes connected to DTX000 connections for lanes 3  4  and 6  and 8  The  DTX000 will wait for these four lanes to finish  Important  Only connect stop sensors for those  lanes in use  Having additional sensors connected will cause the DTX000 to wait for the  additional l
14. implement your large screen display for little or no cost     Large Computer Monitor    10    Many computer users are using fairly large monitors  such as 17     19     or even 21     These  monitors may be large enough for some applications to serve as your large group display     LCD Projector  borrow from local company or rent  Very LARGE Display    Some members of your group may be able to borrow an LCD Projector from work for your race  event  These LCD Projectors take a VGA or SVGA monitor signal and project it onto a wall or  screen  These projectors have the advantage of making a very large display  useful for extremely  large groups  They may also be available as a rental item from your local computer store  This is  becoming perhaps the most popular way to display race results     6  Specifications    Power Consumption   The Handheld unit operates from a 9V battery or AC adaptor  Typical alkaline batteries provide  about 580 mAh of current to 4 8V  at which point the battery should be replaced  The current  required by the DTX000 varies depending upon how many stop sensors are connected  The  current requirements and approximate battery life assuming an alkaline battery are provided  below                                  of Lanes Current  mA  Baitery Life  Hrs    1 24 6 22   2 27 2 19 8  3 29 8 18 1  4 32 4 16 6  5 35 0 15 4  6 37 6 14 4  7 40 2 13 4  8 42 8 12 6                   10 24 MHz Crystal Oscillator  The DTX000 uses a 10 24 MHz Crystal Oscillator to run t
15. l for details on configuring your PC for communicating with the DTX000     The data sent from the DTX000 to the PC will be similar to the following where the data is  provided as 1   Place Lane  1  Place Time  2  Place Lane  2 Place Time  Each new race that  is run will have a new set of times incrementally displayed on the computer screen  The times  displayed on the bottom row are the most recent results   DT2000 shown     DT2000 NewBold Products    12 5455 22 9831  12 6790 23 1288    22 8820 13 5109    Mode 3   DT8000 only     Mode 3 is for installations where 3 or more lanes are to be used  up to a maximum of 8  The  DT8000 automatically enters this mode when stop sensors are connected to 3 or more sensor  inputs  All unused sensor inputs should be left open  After turning the power on  the user should  press RESET to clear the Self test display  After this RESET  the LCD will display    X LANES    to  indicate that stop sensors were found on X Lanes  where X 3 to 8  After pressing RESET again   the LCD will display a dash in the location where each sensor was found  After pressing RESET  again  the DT8000 will enter the timing mode     Timing starts when the start switch moves and continues until all cars have crossed the finish line   passing over the stop sensors  or the elapsed time is  gt  9 9999 seconds  Once the last car has  finished  the LCD will display the finishing order for all cars  The LCD data is formatted to display  from left to right  1  Place Lane  2  
16. lane spacing and  can be used on tracks of different groups without any modification  To accomplish this  the  DTX000 automatically determines the track configuration and adjusts to provide the maximum  information possible  A serial port connection interfaces to virtually any PC and does not require  any custom software  The DTX000 is a software driven device  making the basic system  flexible and inexpensive  While control and display functions are software based  all critical  timing operations are performed in hardware to ensure precision        FEATURES               Timing accuracy to resolution of 0 1 ms   0001 sec      Maximum time of 9 9999 seconds     8 Digit Liquid Crystal Display  LCD      Provides elapsed time and finish order for 1 to 8 lanes  depending on model      Configurable for use on ANY track regardless of length or width     PC Interface  connects to any PC serial port     PC Interface can be used with virtually any PC and NO custom software is required    PC can reset timer  by pressing space bar  lt SPACE gt   PC sends 20h to DT8000     Single configuration regardless of number of lanes in use       Automatically determines lanes in use and selects the correct operating mode     Simple and easy to learn user interface       ABOUT THIS MANUAL    The DTX000 Users Manual contains the information that you need to install and operate the  system and to conduct your Pinewood Derby event  If you are reading this document on your  computer  you can use the bl
17. o your drilled holes     Cable ties and cable holders are provided with your timer  You can position the cable holders on  the bottom or sides of your track and use the adhesive back to attach them  The cable ties can  then be used to bundle your wires together for a neater installation     The stop sensors are provided with 10 foot wire lengths  so the DTX000 handheld unit should be  located about 5 6 feet up from your finish line and several feet away from the track     Installing the Start Switch  see Figure 3    Typically the starter   s lever is implemented in a variety of ways  The start switch can be mounted  to the side of the track with screws  epoxy  hot glue etc  The exact implementation is dependent  on your particular track design  The start switch needs to be installed so that the switch opens  when the starting lever of your track moves to start the race  Also be sure to move the lever  quickly so that cars are not leaning on the Starting Peg as it moves forward  If you impede the  car   s progress with the Starting Peg  the elapsed times can vary from race to race  dependent on  the speed at which the lever is moved  The start switch is supplied with a 40 foot cable length     Garting Peg  x    Qart Witch  Closed Pior to Sart         Install using  wood  screws epoxy  etc  L e    may require a small Bi Qarters Lever  standoff block of wood to   position switch under lever       Figure 3     Start Switch Installation    Routing Cables  You can route your cables
18. on 2 hardware and later    6  AC adaptor connection  allows use of a 9V wall adaptor in place of 9V battery      Version 2 hardware and later   7  18 pin Header     connections for start switch and stop sensors 1 8   8  DB9 Female     connection for PC interface  mates with DB9 Male connector     Turning on the DTX000  Self Test and Selecting the Correct Operating Mode     1  Turn the power on by moving the    Power    switch up     2  The handheld unit now performs a Self Test  It turns on all segments of the LCD and turns  on the LED to allow the user a check of all the displays     3  Once the Self Test is complete  press the RESET button to clear the display and the LED  At  this point  the DTX000 automatically determines how many stop sensors are connected and  which operating mode you will be using     IMPORTANT NOTE  A sensor is only    found    present for a given lane if adequate light is present  on the sensor for that lane  The LCD will display the number of lanes found i e     3 LANES     If no  lanes are found  the LCD will display     This indicates the error situation where no  stop sensors are found present  If this error is displayed  the user should check the stop sensor    connections and light sources  Make sure all sensors are plugged into the unit and make sure all  lights are placed closely above the sensors  Then turn the power off and back on using the  On Off switch  Make sure the correct number of lanes is displayed before continuing        4  Once 
19. ster Problems  Please refer to in program help documentation found when running  DerbyMaster or contact Enterprising Ideas at 1  972  394 0381 or on the web at  www derbymaster com    7 7 RaceVIEW Problems  Please refer to the in program help documentation found when  running RaceVIEW or contact RaceVIEW at 1  860  514 4017 or on the web at  www raceview com    7 8 Grand Prix Race Manager Problems  Please refer to the in program help documentation  found when running Grand Prix Race Manager or contact Lisano Enterprises at 1  303  362     1300 or on the web at www grandprix software central com gprm     8  Contacting NewBold Products  Warranty and Return Policies    We would very much like to HEAR from YOU regarding the DTX000 and how you used it for your  car preparations and race event  Thanks for your input     Send us email  feedback newboldproducts com  Call us  1 866  NEW BOLD or  678  352 0084 Fax   678  352 1444    Mail  NewBold Products  1200 Oakhaven Drive  Roswell  GA 30075    6  Year Parts  amp  Labor Warranty    NewBold Products provides a six year warranty for all equipment  starting from date of purchase  and covering parts and labor  If you believe your equipment needs warranty repair contact us to  let us know the nature of the problem and so that we can resolve it over the phone if possible  If  the problem cannot be corrected over the phone we will request the equipment be returned to us  for repair  The customer is responsible for shipping the product back
20. the number of lanes is found and is correct  the user should press RESET     5  After pressing RESET a second time  the LCD displays on which lanes sensors were found   A dash is illuminated for each sensor found  For example if you have a 6 lane track and only  5 sensors are found the LCD might show the following               to indicate that sensors  were found connected to inputs for lanes 1  2  3  5  and 6  This allows the operator to quickly  identify a problem connection   DT2000 models have 2 lanes max  and DT1000 models use  a single lane     6  Press RESET again to enter timing mode     The DTX000 will enter one of three timing modes  based on the number of lanes found  present     Mode 1    1 Lane is Present  DT1000  DT2000  amp  DT8000   Mode 2    2 Lanes are Present  DT2000  amp  DT8000   Mode 3    3 to 8 Lanes are Present  DT8000 only     When the DTX000 enters timing mode  the LCD will be blank and the LED will be off     Mode 1   DT1000  DT2000  and DT8000 models     In Mode 1  the DTX000 times a single lane  This mode can be used for car development prior to  race events and for conducting single lane time trials     For this mode to work  the stop sensor must be connected to sensor input  1 and all other sensor  inputs should be left open  After turning the power on  the user should press RESET to clear the  Self test display  After this RESET  the LCD will display     1 LANE    to indicate that the stop  sensor was found on for Lane  1  After pressing RESET
21. top Sensors  amp  cables  10 foot length standard     1 stop sensor shipped standard for DT1000    2 stop sensors shipped standard with DT2000    3 stop sensors shipped standard with DT8000  Five Cable Mounts  amp  Cable Ties    Some orders may contain additional equipment such as Stop Sensors  for tracks with 4 or more  lanes   PC Interface cable  AC adapter  Carrying Case and Race Management Software  Note  that the PC Interface cable is a standard DB9 Male to DB9 Female cable with a    straight through     or 1 1 configuration  available from most computer and electronics stores  Race Management  Software such as DerbyMaster and RaceVIEW    is available to enhance the use of the DTX000   s  PC interface  NewBold Products is a distributor for DerbyMaster software from Enterprising  Ideas  while RaceVIEW is available for purchase from Wilson Associates  www raceview com      2  Functional Description    Unit Display  Interfaces and Controls     The DTX000 system is comprised of the handheld unit  start switch  and stop sensor s   The  handheld unit has eight  8  areas of interest  These items are     1  8 Digit LCD     displays finish order and or elapsed time depending upon mode    2  Green LED     when on  indicates that the DTX000 is timing a race    3  Reset Button     used to clear Self Test displays and to reset prior to a new race    4  On Off Switch     turns on power to DTX000    5  Low Battery LED     Red LED above power switch turns on when battery is low    Versi
22. ts per second   1200  Data bits   7  Parity   none  Stop bits   2  Flow control   none  Once  you have setup your session you can save it as    DTX000    or another name and each time you  use the DTX000 you can startup Hyper Terminal and simply load this file  If you are using  another communications program such as ProComm you can make a similar setup file  only the  steps will vary slightly     Note on Font sizes  When using the Hyper Terminal program  or others  you can change the font  size as required  For the best results  especially for large group displays as in Section 5  you  may want to adjust your font so that your results for a single race fill the majority of the screen   s  width  This works particularly well for setups with less than 5 lanes     5  Large Group Displays    NewBold Products has designed the DTX000 to be as affordable as possible and yet provide  maximum performance and flexibility  Yet for some Pinewood Derby events the race results need  to be displayed so that large groups can all view the information in    real time     This real time    feedback adds excitement to the entire event  Because each group will have unique  requirements  NewBold Products has included in this section a number of display alternatives     During the late 90   s  the consumer electronics industry has made large screen TVs  large  computer monitors  and camcorders affordable to nearly everyone  It is the intention of this  section to make the best use of these existin
23. ue hyperlinks to jump between sections  You should read the entire  manual to fully understand and properly use the DTX000  At a minimum you should read  sections 2  3  and 4     Section 2 provides a functional description of the DTX000 describing connections  LCD display   start switch  Personal Computer interface  and a description of each operational mode     Section 3 provides installation information to guide you through installing the start switch  stop  sensors and placing the DTX000 handheld unit     Section 4 describes how the user will use the DTX000 for each mode and specifics on how the  unit interfaces to a PC     Section 5 is our    Large Screen Displays    section describing a number of very low cost ways to  display both the Finish Order and Elapsed Times for large crowds at a Pinewood Derby event   You can use equipment you already have to create an impressive race time display for the  audience     Section 6 describes a few of the more important specifications of the DTX000 product family and  is provided primarily for the more technical reader interested in product details     Section 7 is our Troubleshooting section     Section 8 describes  warranty  return policies and ways to contact us   RECEIVING YOUR SHIPMENT    Your order was carefully packed and inspected prior to shipment  Along with this manual  your  order should contain at a minimum     DTX000 Handheld unit  DURACELL 9V battery installed   Starting Switch  amp  cable  40 foot length standard   S
24. utions  Note  All of these converters allow you to run your VGA monitor and one or  more televisions simultaneously  They also all require your television to have either a video or S   video input  most newer television have both   Refer to your television   s documentation to  confirm that it has this type of video input available     PCConnection  1 800 800 0009  www pcconnection com   1  Part    28607  Mfg  Focus Enhancements Inc   Model  Tview Micro  Cost   89 95   Features  VGA In  Composite  RCA  or S Video out  also VGA out  NTSC  640 x  480  24 bit color    2  Part    49057  Mfg  Focus Enhancements Inc   Model  Tview Silver  Cost   139 95   Features  Similar to Tview Micro except for 800 x 600 resolution    3  Part    46511  Mfg  Avermedia Inc   Cost   139 95  Features  VGA In  Composite or  S Video out also VGA Out  1024 x 768 resolution     Jameco Electronics  1 800 831 4242  www jameco com  1  Part    105208  Mfg  Avermedia Inc   Cost  89 95  Features  VGA In  NTSC or  PAL out also VGA out  640 x 480 resolution   2  Part    150447  Mfg  Maruda  Cost   89 95  Features  VGA In  NTSC or PAL  output  640 x 480 resolution     Laptop with NTSC Output    A number of laptops  several made by Compaq  come standard with a video output intended to  drive the video input of a Television or video monitor  The laptop   s video output can be used to  drive a large Television  perhaps 27    or larger  If you have a member of your group with this type  of laptop you may be able to 
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
Origin Storage 250GB TLC SATA  - DEFICIENT VII - annar diagnóstica  Epson 4056 Printer User Manual  Mode d`emploi Stratify  取扱説明書 ドライブレコーダー TEDVR11  書類提出期限は成約日を含む7日以内です。※  XE-A137/A147 Operation-Manual DE  MANUAL T38 V2 081205  Yuvarlamalı kanal açma  2 - CONRAD Produktinfo.    Copyright © All rights reserved. 