Home
User Manual
Contents
1. Recommended values MinSpeed MaxSpeed MotorType Wiring Halfstep Power Power moving Stopped Lunatico 10 8 unipolar Lunatico Optional 100 0 RoboFocus 5 unipolar rf moonlite Optional 100 0 FeatherTouch 3 bipolar lunatico Optional 100 0 Typ DC 50 50 DC lunatico No 100 0 Tarsier users manual rev 1 1 9 21 11 2013 Tarsier users manual rev 1 1 10 21 11 2013
2. current position before switching it off This can be accomplished simply by pressing Menu long press before switching it off until the message position saved is displayed b Saving the fully racked in position in the list It may be convenient to store this position as one the first of the goto points in the controller Doing so it won t be needed to save the position everyday just the first one and packing to go back home will be faster Beware however if you plan to use temperature compensation and the temperature is stored with that position this will void the algorithm as it will believe that point to be a valid focus point for that temperature A trick for this to work not fooling the temperature compensation press the direction buttons until the focuser is fully racked in x carefully unplug the motor so the temperature sensor is also removed in general it is not recommended hot plugging just be careful this time 2 wait a few seconds until the temperature reading disappears from the main screen it will be replaced by No temp please be patient until the No temp is fixed on the screen it may take a while as the temperature readings are averaged 2 now long press Ok to save the point to the list 2 Also long press Menu to store the position as the one it will start from on power up You can now go to the Saved points menu option to check the curr
3. number should be related to the length in steps of your CFZ critical focus zone I suggest to use 1 2 the CFZ Low accuracy steps e number of steps a normal press of the lt lt and gt gt buttons will imply Motor type e used to select unipolar stepper default bipolar DC or even step direction interface Wiring e Lunatico default Lunatico reversed motion RF Moonlite RF Moonlite reversed Backlash e backlash of the setup in steps Halfstep e true or false to drive the motor in full default steps or halved ones Power while moving of the input power to be applied to the motor while in motion PWM Power while stopped Tarsier users manual rev 1 1 6 21 11 2013 e same as before while the motor is stopped defaults to 0 only change if very sure of what you re doing v Reset position e sets current position as 0 then cleans the saved points list and also updates the power on position to 0 m Backlight v adjust the brightness of the screen m Contrast v adjust the contrast of the screen m Volume v adjust the volume of the key click Tarsier users manual rev 1 1 7 21 11 2013 A few final notes a About focuser position when storing the telescope If you want your goto points or your absolute temperature tracking parameters that is when you select from saved point to work between sessions then it is important that the Tarsier memorizes the
4. Seletek Tarsier Users manual Tarsier users manual rev 1 1 1 21 11 2013 The Seletek Tarsier has been designed to assist in the task of focusing a telescope in those situations where a computer is not desirable or available While it will not perform auto focusing functions it will make the task of focusing much easier as it will drive almost any kind of motor from inexpensive DC ones to high accuracy stepper ones as you won t touch the focus knob the scope will not vibrate thus making the process faster and more accurate focus positions can be permanently stored for a repeatable positioning of the imaging train it includes a display to make the process much easier and last if a careful calibration is done it will track the temperature as the session progresses and will automatically move the focuser to the correct position avoiding the need to manually refocus every time Setup For the device to operate you will have to supply k a 12V DC power supply standard power jack positive inside a suitable motor coupled to your telescope focuser either a stepper one any of the Seletek focuser motors and plates apart from motors by Technical Innovations Moonlite FeatherTouch Lakeside These motors will use the DB9 connector of the Tarsier 2 or an inexpensive DC one from Orion Rigel systems or many others These ones will connect to the mono audio jack of the Tarsier Optionally an e
5. ased on the temperature drift from this moment Press Menu to leave the temperature compensation mode no other buttons will have any effect while active v from saved point the controller will understand the scope is NOT correctly focused and will first move to the position matching the current temperature then apply corrections based on the temperature drift from this moment This feature is the most powerful to users with a fixed imaging train as if the focuser is not moved manually disengaging the motor at any time the can be up and running in no time Press Menu to leave the temperature compensation mode no other buttons will have any effect while active v Parameters will simply display the parameters calculated for the current set of points showing the slope and the offset Tarsier users manual rev 1 1 5 21 11 2013 m Motor configuration SUBMENU v v Minimum speed e specify the minimum speed of the motor in milliseconds step Maximum speed e specify the maximum speed of the motor in milliseconds step Note as it is specified in ms step the value for min speed should be higher than the value for max speed High accuracy steps e this number defines the number of steps that the focuser will move when the buttons lt or gt are pressed normally will wait for the temperature correction algorithm before applying any actual movement So basically this
6. e internal list Tarsier users manual rev 1 1 5 21 11 2013 So far we can already operate our Tarsier no configuration is needed in many cases and our focusing experience has already improved compared to a fully manual operation Take make the most of the Tarsier however it is recommended to keep reading From the MENU we will access quite a few options m Saved points m Jemperature compensation SUBMENU v from current point v from saved point v parameters m Motor configuration SUBMENU Minimum speed Maximum speed High accuracy steps Low accuracy steps Motor type Wiring Backlash Halfstep Power while moving Power while stopped Reset position IISISISSISISSISISSSS m Backlight m Contrast m Volume Pressing OK at any option will go down in the MENU pressing MENU will go up until back to the main screen Tarsier users manual rev 1 1 4 21 11 2013 Detailed description of options m Saved points Access to the list of saved positions use the direction keys to navigate OK to perform a goto to the displayed point ong press of OK to delete the point The points with stored temperature reading will be used for the temperature compensation algorithm Menu to go back m Temperature compensation SUBMENU more on temp comp Later v from current point the controller will understand the scope is already correctly focused and will start applying corrections b
7. ent position was saved with no temperature attached c About temperature compensation in general The accuracy of this approach will depend on motor and focuser quality and on the thermal 1 The other way of applying temperature compensation focusing first will always be available whatever the focuser position as long as you don t change the focal length of the setup Tarsier users manual rev 1 1 8 21 11 2013 behavior of the telescope With a good stepper motor not with a DC one and a decent focuser if you are careful setting it up you ll be surprised of the results In order to maximize the possibilities of success you should remember that It is recommended to place the temperature sensor in contact with the OTA covered in such a way that no wind affects the reading Usually the tubes shrink with the fall of temperature of the night So it is better to do the first focusing outwards pulling out the focuser to do it match with small compensation motions that will also be outwards A good backlash calibration will be of real help in case the motor has to change direction And of course and foremost a careful selection of points as perfectly focused as possible and good temperature readings Last for those curious even if the temperature is displayed in approx Celsius degrees no decimal places it is stored in the system in 1 37 degree increment far more than enough for the purpose of focusing
8. xternal temperature sensor again compatible with all other Seletek models Tarsier users manual rev 1 1 2 21 11 2013 Operation of the Tarsier One powered we ll be presented with the main screen pas where we can see the actual position of the motor 0 If we have installed the optional temperature sensor the current temp in C will also be displayed First please note the buttons can be pressed in two ways a normal one button pressed and released in a few tenths of a second and a ong one if the button is kept pressed for longer So going to business the buttons will operate in the following way Menu normal press gt access the MENU Jong press gt save the current position see later in the manual gt and lt gt move to either direction in a slow way that lt meaning normal press the motor will move a small number of steps you can define that number from the MENU ong press it will move continuously at the slowest speed defined until the button is released gt gt and lt lt gt same as before but faster PE Sn normal press the motor will move a higher number of steps you can also define that number from the MENU long press it will move continuously accelerating from the slowest speed defined to the fastest one OK Jong press gt the current position and temperature if available will be stored in th