Home

User Manual

image

Contents

1.
2. White backlight Press and hold the 9 key Release when the desired brightness is reached Brightness level 1 10 is displayed on the LCD during adjustment 0 AY HOME ARMED 2 ARMED _ gt pees Pra 45678 aattlll 10 Levels Red backlight Saturn Keypad has a unique high visibility flashing RED backlight mode which is triggered by any alarm event The red backlighting is designed to be especially visible to alert you that an alarm event has occurred and is present in the alarm memory Adjust LCD brightness Red backlight Press and hold the 7 key Release when the desired brightness is reached Brightness level 1 10 is displayed on the LCD during adjustment eee A O Give ONMEDA 2 Y Sring P Thaeanee T mmtlli 10 Levels agem 8 aF ome Red backlight options The flashing red backlight option has three methods of operation selectable by options 1 to 3 Press and hold the 8 key Release when the desired option 1 2 or 3 is reached Red backlight Options mr 1 Red backlight is cleared by any keypress Default 2 Red backlight flashes until the Alarm Memory icon is cleared Red backlight is disabled SATURN OPERATION Special Key Functions These Double Key functions are only available when the Saturn keypad is used with D8x D16x panels V6 and later Not applicable to previous panel versions Panic Alarm 1 Press the two Panic keys together for PANIC a
3. E To operate Saturn double key 2 Press 1E 5E to turn an option ON or OFF functions press and hold the matching 1E ON enables double key PANIC keys for at least 1 5sec In normal 2E ON enables double key FIRE operating mode only keypad pairs are 3E ON enables double key MEDICAL disabled in programming mode 4E ON enables Entry Chime in Day mode RELATED OPTIONS Used to announce entry in Day mode P61E 5E 8E Keypad PANIC outputs 5E ON enable Chime in Saturn keypads P75E 2E Report MEDICAL alarms Used to announce entry in Monitor mode P75E 3E Report PANIC alarms P75E 4E Report FIRE alarms L LF CORPORATION NS at es oy Certified System www ness com au MADEN IN N55 AUSTRALIA C NESS SATURN KEYPAD INSTALLATION amp OPERATION NOTES Revision 1 Document Part Number 890 405 For the products 106 108 WHT Saturn Keypad White 106 108 BLK Saturn Keypad Black 106 108 OMT Saturn Keypad Ocean Mist COPYRIGHT NOTICE All rights reserved No part of this publication may be reproduced transmitted or stored in a retrieval system in any form or by any means electronic mechanical photocopying recording or otherwise without the prior written permission of Ness Ness reserves the right to make changes to features and specifications at any time without prior notification in the interest of ongoing product development and improvement 2011 Ness Security Products Pty Ltd ABN 28 069 984 372
4. INSTALLATION amp OPERATION INEZ Product part number Document part number Image Saturn keypad White Saturn Keypad 106 108 WHT Saturn Keypad White 106 108 BLK Saturn Keypad Black 106 108 OMT Saturn Keypad Ocean Mist 890 405 Architecturally designed premium keypad Glossy glass look fascia High Contrast LCD icon display White and Red LCD backlighting Red LCD backlighting for alarm memory Satin finish tactile buttons Laser etched graphics Adjustable keypad beep volume Adjustable LCD brightness Adjustable blue keypad backlighting Supports D8x D16x V6 panels To release the keypad from the base push the two locking lugs at the bottom QO THOME ARMED ARMED 2 of the keypad and lift the keypad out and 12345678 Ara 9 10 11 12 13 k To fit the keypad to the base align the OK D z ta wis Oe top locating lugs then swing the keypad RYTON THES Seine MEY OT down to lock the bottom lugs Accessories supplied 1 x 4 wire loom 2 x Low profile self tapping screws 2 x Low profile machine screws 4 x Gel crimp connectors IMPORTANT NOTE To achieve an extremely low profile this premium keypad is designed with close internal tolerances Push lugs with a Use only the Low Profile flat screwdriver to screws provided Larger release keypad screw heads may damage the circuit board and invalidate your warranty 2 x mounting holes to suit single gang wall bracket saddle Cable ent
5. larm Press O O and hold the keys for at least 1 5sec 2 If programmed by the installer the Panic keys are also used to turn AUX outputs ON or OFF See D8x D16x V6 Installation Manual P141E P144E To operate AUX1 press 11 to turn on press 11 to turn off To operate AUX2 press 22 to turn on press 22 to turn off To operate AUX3 press 33 to turn on press 33 to turn off To operate AUX4 press 44 to turn on press 44 to turn off Fire Alarm Press the 1 amp 3 keys together for FIRE alarm Press and hold the keys for at least 1 5sec Medical Alarm Press the 4 amp 6 keys together for Medical alarm Press and hold the keys for at least 1 5sec NOTE Fire Alarm and Medical Alarm are disabled by default See P126E control panel programming SATURN PROGRAMMING For the Installer Programming Programming option P126E in the D8x D16x V6 and later control panels enable the Saturn KP Panic Medical and Fire alarms as well as the Chime mode Saturn can also be used with previous versions of D8x D16x panels but these Saturn options will not be available 2E O D8x D16x PANEL KEYPAD OPTIONS PROGRAM MODE LEVEL The Saturn keypad has keypad pairs for Panic Installer Program mode NessComms Fire and Medical alarms and special chime V5 3 or later modes These program options are available only in FACTORY DEFAULT All a z D8x D16x V6 and later NOTES TO PROGRAM e One or all options can be enabled 1 Press P126
6. ry Recess cutout 47mm x 76mm INSTALLATION Se Wiring Keypad should be wired to the control panel using minimum 7 020 security cable Up to three Saturn keypads can be connected per control panel as long as the maximum current draw for all detectors and keypads is below 500mA Maximum allowable cable distance is 100m including cable to all keypads Wire additional keypads in star configuration to the control panel Saturn Keypad REAR D8x D16x Main Board Crimp connectors Supplied SATURN OPERATION Unique Features Adjustable White LOD back lighting Adjustable red LCD backlighting for Alarm Memory Stylish and elegant J Key pairs for Panic Fire glass look fascia ane aes amp Medical alarms Satin finish buttons Adjustable keypad beep with tactile click volume Adjustable blue keypad backlighting Low installation profile Adjust Chime Volume Press and hold the 0 key Release when the desired volume is reached A short beep will be heard at the highest level atti 10 Levels Adjust Key Beep Volume Press and hold the P key Release when the desired volume is reached A short beep will be heard at the highest level cattfl 10 Levels SATURN OPERATION Adjust Keypad Backlight Brightness Press and hold the 6 key Release when the desired brightness is reached A short beep will be heard at the highest level calli 10 Levels Adjust LCD brightness