Home

PDF/PMINISW Final manual-1 - Orion Air Conditioning And

image

Contents

1. COMPULSORY FIXING POINTS MINIMUM DISTANCE FROM CEILING E EXTRA FIXING POINTS TO USE IF THE WALL IS NOT SOLID S Q 726 62 62 62 62 62 62 EE zin E Bg Le e i si t e e F 9 N F HOT AIR e AIRINTAKE HOLE e DISCHAGE 12 8 v X PJ d E md 2 Remark 160MM TWO COMPULSORY 1 60 FIXING POINTS FOR INDOOR PIPE ADAPTORS 26 ci 28 DRAINAGE HOLE E i 241 _ MINUMUM DISTANCE u i All Dimensions are in MM SAN rawing paper size A1 1 2 Template Fasten the template to the wall once the following guidelines have been oe checked Do not drill any holes until you are 100 confident that there are no obstacles in the area you wish to drill and there are no obstructions which could be hidden by the construction of the wall for example Electrical wiring water amp gas pipes or supporting lintels or beams Ensure that a spirit level is used as the unit must be level e Follow the installation instructions amp measurements in full 3 Drilling the Wall Please note If you are drilling the hole above ground floor level please ensure that the outside area is supervised until drilling has been completed AND OUTLET HOLES This operation should be carried out using the proper tools diamond tip
2. The manufacturer cannot be held liable for damage caused to property or injury to persons or animals due to incorrect installation regulation and maintenance or improper use This air conditioner contains R407C refrigerant at the end of its life the disposal of this air conditioner must be in accordance with the strict regulation governing the recycling of this product please operate with caution during the disposal Please contact your local authority for regulatory advice DO NOT switch on before having totally assembled the air conditioner and before installing in its correct operating position C IMPORTANT SAFETY INSTRUCTIONS Always place the unit on an even level surface An opening in a window in portable version only or wall is required to accommodate the exhaust hose to expel the hot air Ensure the unit is connected to an earthed power supply of the correct rating Refer to the rating label located at the back of the unit The unit will cool when the room temperature is between 18 C 32 C depending on the thermostat setting DO NOT use this unit for functions other than those described in this instruction manual DO NOT tilt the unit DO NOT cover or obstruct the appliance s inlet and outlet grilles Your air conditioner has been designed to be used only in the home office and similar conditions and should not be used for any other purpose This unit is for indoor use only Never unplug the air conditioner while
3. installed b Plug the Power Cord into the power outlet socket C Turn on the unit by pressing the ON OFF Button on the control panel d Press the MODE Button until the og appears on the VFD display NOTE The unit operates at low fan speed during dehumidifying The unit cools room slightly during dehumidification Keep the windows and the doors closed to aid the effectiveness of the unit in removing moisture from the room The unit will not perform dehumidification when the room temperature is lower than 61 3 Fan Operation a Plug the Power Cord into the power outlet socket b Turn on the unit by pressing the ON OFF Button on the control panel Press the MODE Button until 96 appears the VFD display Select the fan speed by pressing the FAN Button O NOTE When the unit is running in fan mode the exhaust duct is inoperative and is not required 4 Heating Operation a Plug the Power Cord into the power outlet socket Turn on the unit by pressing the ON OFF Button on the control panel c Press the MODE Button until AK appears on the VFD display Press the button UP or DOWN until the desired room temperature appears on the VFD The temperature ranges from 16 C 31 C e Select the fan speed by pressing the Fan button It is recommended to use the low fan NOTE When activating the heat pump the unit will shut off for 3 5 minutes before starting the heating operation For
4. P5 Air exhaust hose P6 Adapter for window panel P7 Adjustable window panel P8 Butter fly screw x 2 P9 Screwx4 P10 Insulated sleeve Schuko to UK converter plug This Schuko to UK converter plug is used in this product Refer to UK plug wiring instruction section for regular UK plug wiring F WALL MOUNTING INSTALLATION INSTRUCTIONS Positioning the air conditioner e To obtain maximum performance OUTDOOR from your unit it must be correctly positioned Please following the guidelines and instructions below in full as failure to do so could cause potential installation problems e air conditioner must be installed on an exterior wall that __ has access to the outside and a minimum of 2 meters free Zn clearance to allow good airflow NE e The unit must be fitted 4 INDOOR following the template with space to the top bottom and sides of the unit The wall on which the unit is installed must be sturdy and able to withstand the weight of the unit After determining the best place for installation as described above please check to ensure that the wall can be drilled without causing damage to the fabric of the building If necessary obtain professional advice to ensure that no damage is done to power supply or water pipes Please also ensure that there are no obstacles on the outside of the wall which may interfere with the performance of the unit
5. after it is thoroughly dried d Ifthe filter is damaged or unusable order a new filter by calling your local service agent or supplier 2 Case a Keep the unit from being exposed directly to the sun to prevent colour fading b Clean the surface with a damp cloth Dry it with a soft towel 3 Storing the Unit for an Extended Period of Time or Transporting a Empty water by unplugging the water drainage stop at the back towards the bottom of the unit b Unplug the unit c Theunit should be stored in a cool dry place K TROUBLE SHOOTING Please check the following items before asking for repairing PROBLEMS CAUSES SUGGEST SOLUTIONS The unit does not work Power supply fault 1 Not plugged in 1 Plug in correctly 2 Faulty plug or socket 2 Change the plug or socket 3 Fuse broken 3 Replace fuse The unit stops running Timer is set or room Close the timer or reset temp automatically temperature is lower than set temperature In cooling mode no cooling 1 Room temperature is 1 This is normal air coming out lower than set temperature 2 There is frost on the 2 The unit is defrosting and it surface of evaporator will run when the defrosting is finished The remote control does 1 Exhausted batteries 1 Change the batteries not work 2 Batteries incorrectly 2 Re install the batteries installed correctly The unit does not work for Protection of the unit Wait for approx 3 minutes and 3 minutes wh
6. be pushed firmly against the wall Carefully inspect the installation to ensure that the insulating back panel fits firmly against the wall and there are no gaps at the back of the air conditioner LIFT IT UP HERE A F s LIFT IT UP HERE G ASSEMBLY INSTRUCTION FOR MOBILE ONLY only available in combi model If combi model is purchased the mobile accessories are included 1 Castors kit Two sets of castors system provided e Lift up the unit carefully DO NOT TURN THE UNIT UPSIDEDOWN e Fitthe tongue of the Castor Frame in the square hole on the bottom of the base plate Screw the castor frame on the back panel of the unit with the butter fly screw Tongue Location of Square hole Butter fly screw 2 Window Kits Note Your window kit has been designed to fit most standard vertical and horizontal window applications However it may be necessary for you to improvise modify some aspects of the installation procedures for certain types of windows Please refer to measurements i inl Window slider kit minimum 72cm maximum 1 40cm Window slider kit minimum 72cm maximum 140cm 3 Hose and grille Screw the Metal Grille P2 to cover the right hole on the back of the unit Screw the Unit Flange P3 to cover the left hole on the back of the unit Select a suitable location make sure you have easy access to an electrical Socket e Remove the hose window exhaust adapter and window
7. it is working this could damage the electronic circuits DO NOT use the appliance in a wet room such as a bathroom or laundry room to avoid the risk of electrical shocks DO NOT bend or crush the warm air exhaust hose in portable version only DO NOT sit or place articles on the appliance DO NOT use the appliance with wet or damp hands DO NOT let chemical substances come into contact with the appliance DO NOT use the appliance in the presence of flammable substances or vapours such as alcohol insecticides petrol etc DO NOT use the plug to start and stop the appliance ALWAYS use the intended control panel to start and stop the unit ALWAYS turn off the appliance when it is not in use and remove the mains plug from the socket outlet ALWAYS turn the unit off and remove the mains plug before cleaning carrying out maintenance or moving location Do not pull the electrical cable or place it near a source of heat always unroll it completely to avoid dangerous overheating If the power cord becomes damaged the service agent or a similarly qualified person must replace it in order to avoid a hazard The filter must be used with the product at all times when removing it for clearing always turn the unit off and unplug the mains plug from the Socket Do not operate the unit with a damaged power cord or plug after it malfunctions has been dropped or damaged If the power cord is damaged it must be replaced by the manufacturer or a
8. or core bit drills with high twisting torque and adjustable rotation speed e Fasten the template to the wall taking care to check the distance from the floor and or ceiling and keep horizontal by using a spirit level Use a pilot drill to mark the centre of each core hole to be drilled Use a core boring head having a diameter of 135mm to drill the two holes for intake and outlet air e Itis recommended that the holes must have a slight downward inclination of 3 5 degrees to prevent any backflow of water from the pipes Drainage The unit produces condensate that has to be extracted to enable the unit to operate correctly It is necessary to drill a hole through the wall measuring 30mm in diameter in the position shown in the template Drainage occurs by gravity For this season it is essential for the drain line to have a minimum downward inclination of at least 396 throughout its length 3 Fastening the bracket e Drill the holes for anchoring the fastening bracket to the wall using the 6 holes showed in black on the template If the wall is not sturdy enough it is advisable to use extra anchor bolts using the holes showed in grey on the template e The anchor bolts provided require 8mm holes the wall should be inspected to determine if provided bolts are sufficient No liability can bee accepted by the manufacturer or his agent in case of underestimation of the structural consistency of the anchorage made at the time of inst
9. qualified service engineer to avoid a hazard Closely supervise any children and pets when unit is in use Energy Saving Tips Blocking of the filter reduces the efficiency of the air and increases its power consumption by up to 696 Avoid opening doors frequently Each person present in a room provides between 100 Watts and 150 Watts of heat Consequently the more people there are in a room the less effective the unit will be in cooling To ensure the optimal efficiency of the unit we advise you to keep doors and windows closed and to take into account the surface of the walls and windows exposed to the sun Avoid the use of adapter plugs multiple sockets and or extension leads If their use is necessary ensure they conform to current safety standards Before starting the appliance check that it is correctly earthed according the legislation in force in the country concerned READ AND SAVE THESE INSTRUCTIONS D BS PLUG WIRING Wiring Instructions Should it be necessary to change the plug please note the wires in the mains lead are coloured in accordance with the following code BLUE NEUTRAL BROWN LIVE GREEN AND YELLOW EARTH As the colours of the wires in the mains lead of this appliance may not correspond with the coloured markings identifying the terminals in your plug proceed as follows 1 The BLUE wire is the NEUTRAL and must be connected to the terminal which is marked with the letter N or coloure
10. PREM I AIR 8000BTU AIR CONDTIONER COOLING amp HEATING Model PMINISW8W PMINISW8C CSI PLEASE READ THIS INSTRUCTION MANUAL BEFORE OPERATING AND KEEP SAFE FOR FUTURE REFERENCE CONTENT E Product description 8 9 F Wall mounting installation instruction 10 14 G Assembly instruction for mobile unit only available 15 16 in combi model Operating instructions 17 21 Operation using remote controller J Maintenance K Trouble shooting L Service amp warranty A SPECIFICATION PMINISW8C o o a ap Dehumidifying Capacity 25 Net Weight KG not includes accessories 2 Dimension 465 765 235 iw Notes 1 Cooling capacity is measured at ambient temperature Dry bulb 27 C Wet bulb 19 C Indoor and outdoor the same Heating capacity is measured at ambient temperature Dry bulb 20 o Wet bulb 15 Indoor and outdoor the same B BEFORE USE Transport amp store the unit in an upright position only Leave it in an upright position for at least 3 hours before first use DO NOT dispose of any packaging until the installation of the air conditioner is completed After having removed the packing check that all the content is intact and complete See list of accessories In the event of missing parts contact your retailer This air conditioner has been designed to cool or heat the air of a room and should only used for the purpose
11. allation 4 Installation of vent tubes After drilling the holes the plastic pipes supplied with the air conditioner need to be fitted through them The pipe with a diameter 130mm hot air discharge has to be fitted in the right hole The length of the pipes should be matches to the thickness of the wall Fit the plastic pipe into the hole and fasten the flange with 2 M4 screws on the wall Please use the same instructions to fit the left hand tube air intake pipe using the supplied pipe with a diameter of 120mm The tube diameter is slightly smaller than that carried out using the 135mm nominal diameter core drill Please centre the pipe into the hole in the wall and insulate and seal using polyurethane foam to prevent air and humidity penetration Fit the drainage pipe into the pre drilled hole and seal as above A further extension pipe can be fitted if necessary 5 Remove the screws on the filter Please remove the 2 screws before fastening the unit on the bracket 6 Fitting the unit on bracket After checking again that the fastening bracket is securely fastened to the wall and that any necessary preparations for electric connection and condensate drainage have been made tilt the unit slightly towards you to aid the operation of fastening the unit onto the bracket Fit the drainage pipe that protrudes from the back of the unit which is then inserted in the drainage hole The air conditioner can now
12. by press SWING button once To stop press the SWING button again Horizontal air flow direction can be adjusted manually TIME ON To program the timer press TIME ON button until the VFD display shows a flashing O gt I to set automatic ON time while the unit is ready TIME OFF Press TIMER OFF button and the VFD display will show a flashing O to set automatic OFF time while the unit is running 10 HR Press to set the desired hour setting 11 MIN Press to set the desired minute setting NOTE ALL SETTINGS CAN BE VIEWED ON THE REMOTE DISPLAY J MAINTENANCE Note Make sure power is off and the plug is pulled out of the power outlet before performing any maintenance activities 1 Clean or replace filter If the air filter is blocked with dust the airflow volume will reduce is recommended that the filter be cleaned at least once every two weeks a Pull up the filter from the filter compartment in the back of the unit For portable unit please remove the 2 screws on the filter first before remove filter to clean REMOVE THE 2 SCREWS FOR GLEAN THE FILTER ry yy TF Ai ed at ial ad JRE 1 B or eF E j 1 d D E i Lu ER X PUSH THE 2 HANDLES TO TAKE OFF THE FILTER b Wash the air filter by immersing it gently into warm about 400C water with a neutral detergent Rinse the filter and dry it thoroughly in a shaded place c Replace the filter back into the filter compartment
13. d BLACK 2 The BROWN wire is the LIVE and must be connected to the terminal which is marked with the letter L or coloured RED 3 The GREEN YELLOW is the EARTH and must be connected to the terminal which is marked with the letter E or e or coloured GREEN OR GREEN YELLOW 4 Always ensure that the cord grip is positioned and fastened correctly If a 13A BS 1363 fused plug is used it must be fitted with a 13A fuse If in doubt consult a qualified electrician Wiring for a 13 Amp Plug BS1363 Please note The Earth Terminal is marked with the letter E or Earth Symbol E PRODUCT DESCRIPTION ree lege optional NN using in mobile version onl ee using in mobile version only 4 Control panel 11 _ Air exhaust 5 Handles 12 6 Dust filter Drainage hole 7 Hanging holes for wall mount 14 Caster bracket hanging hole brackets using in mobile version only Standard accessories A1 Remote control A2 Fix head with manual adjust louvre Pre installed A3 User manual A4 Drain hose 5 Rubber plug Batteries not included Wall mounted kit W1 Wall bracket W2 Pipe flange W3 Air intake pipe dia 120mm W4 External grating W5 Hot air discharge pipe dia 130mm W6 Template for wall drilling W7 Extension condensate hose W8 Screw kit Mobile kit optional P1 Castors assembly P2 Metal grille P3 Unit flange P4 Air exhaust hose connector
14. en switched the unit will start on Error code E2 in VFD Failure of the indoor sensor Change the indoor display temperature sensor Error code E3 in VFD Protection of cooling mode display display sensor display motor display or missing display Error codes are for information only Advise your local service agent as appropriate L SERVICE amp WARRANTY e Do not operate the unit with a damaged cord or plug after the unit malfunctions or has been dropped or damaged e For your convenience record the complete model number and product name located on the Product Identification Plate the date you purchased the product and attach your purchase receipt docket as proof of purchase To ensure your product is covered by warranty the complete faulty product together with your purchase receipt should be returned to your retailer ONE 1 YEAR LIMITED WARRANTY Save This Warranty Information EHS International Ltd Guarantees this product free from defects in materials and workmanship for a period of one 1 year Should this unit be operated under conditions other than those recommended at voltages other than the voltage indicated on the unit or any attempts made to service or modify the unit will render this WARRANTY VOID The product you buy may sometimes differ slightly from illustration This warranty is in addition to and does not affect your statutory rights Should you have a problem with th
15. is product please call our Help Desk on 0870 742 5021 This product has been manufactured to comply with EEC Directives 2006 95 EG and 89 336 EEC Waste electrical products should not be disposed of with household waste Please recycle where facilities exist Check with your Local Authority or retailer for recycling advice f HS FHC Internatianal t EE EHS Manchester M17 1RN EHS 05 08
16. l the VFD display shows a flashing 1 to set Automatic Off time while the unit is running Press Timer button and the VFD display will show a flashing 97 to set Automatic On time while the unit is in ready state Press either UP or DOWN buttons to set the clock to the required turn off time or turn on for1 hour by pressing once The adjustable time range is 1 hour to 12 hours The light will flash for 3 seconds to activate the timer which has been programmed programmed Press the TIMER button again to cancel the setting OPERATION USING CONTROL PANEL 1 Cooling Operation a If using in mobile mode ensure that the exhaust duct is correctly installed b Plug the Power Cord in to the power outlet socket C Turn on the unit by pressing the ON OFF Button on the control panel d Press MODE Button until BRS appears on the VFD display e Press UP or DOWN until the desired room temperature appears on the VFD The temperature ranges from 16 C 31 C f Select desired fan speed by pressing the FAN Button NOTE During hot days the unit will cool off the room most efficiently by setting the temperature at the lowest and the fan speed at the highest Reducing the length of the exhaust duct and insulating the exhaust duct and keeping direct sunlight to a minimum will also improve the cooling efficiency 2 Dehumidifying Operation a If using in mobile mode ensure that the exhaust duct is correctly
17. panel kit install the flexible hoses insert the end of the hose with the round connector turn the connector clockwise on the Unit Flange Screw the window exhaust adapters on hoses by turning them clockwise e Insert the air outlet window exhaust adapter into the hole of the window panel kit Adapter for window panel n Air exhaust hose Connect of air exhaust hose Adjustable window panel Unit Flange Metal Grill 4 Filter screws Please fasten filter screws if it is removed in wall installation Always fasten the filter in portable Only remove it in cleaning H OPERATION INSTRUCTIONS CONTROL PANEL TH an ER 5 i aari H METTE AUS I UL ELI Control Panel Functions 1 On Off otarts or Stops the Unit 2 Mode Select the functions of the unit for Auto Mode NZ Cooling Mode Dehumidifying Mode Fan Mode 96 Heating Mode 7 5 Fan Speed Control Piddi Select the fan speed for High Medium Low The fan speed can be visually distinguished by the speed of the digital air segments progressing out from the windmill fan image on the VFD display Temperature Select the desired temperature by pressing either UP or DOWN button when using the unit in cooling or heating function The VFD flashes to display the desired temperature during setting it displays the room temperature after 5 seconds TIMER Press TIMER button unti
18. rn to the originally set figure g When in dehumidify mode the temperature will not be changed NOTE In exceptional conditions of low temperature and high humidity condensate may accumulate at a rate faster than it can be discharged The symbol ET will appear in the control panel In order to restart the unit it is advised that the drain port is utilized You should use a container of at least 1 5ltr capacity to collect the condensate This normally applies when used in mobile mode OPERATION USING REMOTE CONTROLLER 1 Remove the cover from the back of the remote control Insert two AAA dry cell batteries batteries included Insert the power plug into an outlet Always point the remote control signal transmitter toward the unit when operating Make sure that the signal path is not obstructed The maximum distance at which signals can be received is 8M Remove the batteries if the unit is not going to be used for an extended period of time N o o A CHANGE IN THE FUNCTION IS USUALLY INDICATED BY A BEEP 8 DO not abuse the remote control 9 Do not place the remote control in a location that is exposed to direct sunlight or next to a heating unit or other heat source 10 Do not use rechargeable batteries because they differ from standard dry cell batteries in shape dimension and performance 11 Be sure to replace the batteries with two new batteries of the same type IMPORTANT At the end of
19. the portable type when the unit is running on heating mode stretch out the air exhaust hose to their full length and wrap the insulated sleeve around the hose and secure with the Velcro Do this before installing the exhaust hose into the air outlet ports on the back of the unit 5 Auto Operation a Turn on the unit by pressing the ON OFF Button on the control panel b Press the MODE Button until the X appears on the VFD display C Select the fan speed by using FAN button During AUTO mode the unit operates at heating mode when the room temperature is below 20 C It operates at dehumidifying mode when the room temperature is between 20 C to 26 6 C operates in cooling mode when the room temperature is above 26 6 C You may use the timer with the AUTO mode 6 Sleep Mode This Mode is available when using Remote control a he air conditioner is in operation b Press SLEEP Button the appears on the VFD c he fan motor of indoor unit runs in low speed d When in cooling mode during the first two hours the temperature will be increased 1 C per hour The unit will then operate at 2 C higher than the originally set figure for 6 hours The temperature will then return to the originally set figure e When in heating mode during the first 2 hours temperature will be decreased 1 C per hour Then temperature will be keeping at 2 C Lower than the original set figure for 6 hours The temperature will then retu
20. their life dispose of the batteries according to Local Authority regulations Do not dispose of batteries with your normal household rubbish Chock set button Reset button Remote control real time clock instructions 1 Open the battery cover of the remote control and press the CLOCK button with a pencil or pen 2 Press the HR button and MIN button and adjust the correct time 3 Press the CLOCK set button again and close the batter cover 4 The display will show the correct time 5 Clock Time settings HR and MIN To set the hours press HR button once the time will add 1 hour continue to press this button the clock will add by 1 hour until extended 11 hours then will change to PM or AM and return to 0 12 00 To set the minutes press MIN button once the clock will add 1 minute continue to press this button and the clock will add by 1 minute until extended to 59 minutes the return 00 TO RESET ALL FUNCTIONS ON THE REMOTE CONTROL PRESS THE RESET BUTTON WITH A PENCIL OR PEN REMOTE CONTROL FUNCTIONS 1 2 ON OFF Starts or otops the Unit WARMER Agjust to desired warm temperature COOLER Agjust to desired cool temperature MODE Select the functions of the unit for Auto Mode Cooling Mode Dehumidifying Mode Fan Mode and Heating Mode FAN Select the fan speed desired High Medium and Low SLEEP To set the unit for sleep mode SWING To start swinging air louvers vertically