Contents

1. a If the alarm is not acknowledged before the next recording interval the status signal light turns red Figure 8 38 Plant state Current overall state e Last event 2007 08 04 09 41 35 Alarm is switched on Please acknowledge Alarm off Illustration 8 38 Activated Alarm The reaction time of the relay can be up to 5 minutes This can lead to a slight delay in notification of the alarm contact If the alarm is not cancelled within allowed time interval the status display will turn to red The acknowledgement of an alarm is tracked in configuration events Example of an event notification if a relay is connected A arm relay has been deactivated 8 8 Reports Reports provide a variety of graphic data evaluations representing power and yield in relation to occurred inverter events It is possible to switch between days and months C00410334 01 49 8 Working with ComLynx Weblogger 268 Reports Daily power of entire plant Daily power of plant vi Daily yield of inverters Daily overview of each inverter yield Monthly yield for entire plant Monthly plant yield Yearly yield for entire plant Yearly yield of plant and inverters Illustration 8 39 Overview of Evaluations A variety of representations are possible in accordance with the desired evaluation period Daily power of entire plant The total power of all inverters is represented here in a line diagram
2. Daily yield of inverters The individual yields of all inverters are represented here in a bar chart Monthly yield of entire plant The total yield per month of all inverters is repre sented here in a bar chart Yearly yield of entire plant The total yield per year of all inverters is represented here in a bar chart Depending on the report group it is possible to choose between days and months The various evaluations can be viewed and configured individually for cyclical messaging To open the event group click on the header row of the group All data recorded up to this point will automatically be displayed in the diagrams by the system Depending on the individual report type the report generation can be influenced by different se lection possibilities which will be shown on the time axis as either a line graph or bar chart Additionally all events are indicated in chronological order below the diagram As in the monitoring log the most recent events are indicated here first 50 C00410334 01 Events are recorded as follows Danfoss 8 Working with ComLynx Weblogger Timestamp Date and time of the event Event Event report 0 3 0 25 0 2 0 15 0 1 Interruptions Events Timestamp 2006 09 18 11 40 13 2006 09 18 11 47 29 2006 09 18 11 47 33 2006 09 18 11 48 10 2006 09 18 11 50 29 2006 09 18 11 50 35 2006 09 18 11 51 27 2006 09 18 11 51 34 2006 09 18 12 54 03 2006 09 18 14 00 09 200
3. Illustration 8 10 Editing E mail Parameters The following settings can be made here Parameter Description SMTP server Simple Mail Transfer Protocol server outbox server this information can be requested from your Internet provider see below or LAN administrator Login Internet provider s user name Password Password assigned by the Internet service provider For security reasons every password character is displayed as an asterisk Sender address Sender s e mail address used for authenticating the SMTP server An unknown sender address can cause e mail delivery to fail Authentication type Authentication SMTP on the account information of the email will be given by the internet provider Note As authentication type exclusively SMTP Authentication is sup ported E mails can also be exchanged via free mail providers A prerequisite for e mail exchange here is an SMTP server on the side of the email service provider Attention Not every provider offers this service free check whether fees are charged for e mail accounts such as Premium Plus Extra Professional etc Well known Free mail and Online Services The most well known free mail providers are listed below GMX Incoming mail server Outgoing mail server User name Special features gmx net IMAP imap mail gmx net GMX customer number or GMX e mail address use of the customer number is recom
4. Illustration 5 1 IP Entry Internet Explorers In case the device has to be configured to another IP address the network settings of the PC have to be aligned to those of the ComLynx Weblogger in order to apply changes accordingly i A note should be made of the previous settings of the PC in order to restore them PC Settings Start gt Control panel gt Network connections gt right click on the LAN Local Area Con nection connection and choose Properties gt right click gt properties 12 C00410334 01 Danfoss 5 First Installation Local Area Connection Properties General Authentication Advanced Connect using EJ Intel PRO 1000 PL Network Conn This connection uses the following items mt as Packet Scheduler iPass Protocol IEEE 802 1 3 5 1 0 Interet Protocol TCP IP Install Uninstall Properties Description Transmission Control Protocol lnternet Protocol The default Wide area network protocol that provides communication across diverse interconnected networks C Show icon in notification area when connected Notify me when this connection has limited or no connectivity Illustration 5 2 LAN Connection Properties Select Internet Protocol TCP IP gt Press Properties button gt IP address 192 168 1 191 or the IP address allocated by the administrator Sub network mask 255 255 255 0 Internet Protocol TCP IP Properties General You can get IP set
5. The ComLynx Weblogger can be accessed via a Web browser e g Firefox or Internet Explor er Version 6 or above 8 2 User Rights Access Rights ComLynx Weblogger offers two access levels settings are performed exclusively at the adminis trator level Guest access Guests are able to read but not write all information and data Administrator access Additionally the Admin administrator is able to edit settings For this purpose those with Admin rights need to be authenticated with a username and password Authentification required User admin Password Illustration 8 1 Administrator Login By default the user and password are both set to admin prior to delivery Attention To avoid unauthorised access by a third party the password must be changed im mediately after the first login see Chapter 8 5 6 Clicking on Login establishes the connection 8 3 Web Interface ComLynx Weblogger s main page provides an overview of the selected plant s operational status C00410334 01 23 8 Working with ComLynx Weblogger Danfoss 24 ComLynx Weblogger an gt Plant state ComLynx Weblogger gt Monitoring gt Reports gt Configuration gt Download plant information Description Datenlogger Owner PowerLynx A S plant state Current overall state Last event gt 2007 06 25 11 57 37 n u n2 2 Irradiation Illustration 8 2 Web interface Pla
6. All sensors detected by the system can be viewed and individually configured in the Sensor menu The Search function permits an easy scanning for the sensor module Configuration Sensors Sensor module Search Illustration 8 26 Search Sensor Modules By default theComLynx Sensor Interface sensor module with address 81 is found and calibrated The calibration value of each individual sensor can be entered here it is specified by the sensor manufacturer and can be found on the sensor 40 C00410334 01 2 2 Configuration Sensors Sensor module Sensor modules Sensor Interface Illustration 8 27 Overview Sensors 8 Working with ComLynx Weblogger Clicking on the ComLynx Sensor Interface option opens the related settings window Configuration Sensor module Edit Address 81 Sensor Interface Name e g Plus module Group Status active Sensor Environment temperature sensor PT1000 Module temperature sensor PT1000 Spectron 100 m Impulse counter Power acquisition using transducer 0 20mA Illustration 8 28 Editing ComLynx Sensor Interface connected Calibration value 0 x C 0 x C 73 4 mv at 1000w m2 1000 Impulses kwh 90000 W at 20mA Delete removes the ComLynx Sensor Interface from the system Note the infor mation provided under automatic network scan The following settings can be made here C00410334 01 41 8 Working with Com
7. DHCP My settings Host name Domain name IP address 192 168 1 190 Broadcast address Subnet mask 255 255 255 0 Standard gateway ONS server 192 76 144 66 Cancel Illustration 8 6 Editing Network Settings C00410334 01 27 8 Working with ComLynx Weblogger Danfoss The following settings can be made here Parameter Description Host name e g My Host Domain name Name of domain Ask your network administrator for the domain name Note The following settings are obtained automatically with DHCP IP address Default entry 192 168 1 190 Broadcast address IP address for communicating with all computers in a network Subnet mask Default entry 255 255 255 0 Standard gateway IP address of the Internet gateway This address can be requested from your network administrator DNS server This parameter can be requested from your network administrator I Default network settings for Internet access via a modem e Standard Gateway lt empty gt QO e DNS server 192 76 144 66 8 5 2 Modem Under Moder you enter modem and dialling parameters such as modem type PIN access number login name and password etc necessary for dialling into the Internet Configuration Modem Modem type Standard modem Baud rate 57600 Additional modem configuration Access number Ow0192658 Login name MSN Password wet Te Number of rings 2 until call acceptance Internet dialin disabled switc
8. DK 6400 S nderborg Denmark declare under our sole responsibility that the product ComLynx to which this declaration relates is in conformity with the following directive s standard s or other normative document s provided that it is used according to our instructions 89 336 EEC EMC Directive 73 23 EEC Low voltage Directive Conformance is tested according to the following standards e EN 55011 and EN 55022 9 98 Class B e EN 50082 part 1 Date iH ee Uffe Borup Senior manager Technology 1 200 Z Issued by Arthur Philiposian a LY Girt fs w Approved by 1 1 C00410334 01 Danfoss Solar Inverters A S Jyllandsoade 28 DK 6400 S nderborg Denmark Tel 45 7488 1300 E mail solar inverters danfoss com C004 1 033401 www solar inverters danfoss com Danfoss can accept no responsibility for possible errors in catalogues brochures and other printed material Danfoss reserves the right to alter its products without notice This also applies to products already on order provided that such alterations can be made without subsequential changes being necessary in specifications already agreed All trademarks in this material are property of the respective companies Danfoss and the Danfoss logotype are trademarks of Danfoss A S All rights reserved C00410334 01 Rev date 2008 07 08
9. pop3 web de IMAP imap web de Outgoing mail server User name smtp web de User name Special features Yahoo mail Uses SMTP authentication or POP3 before SMTP Outgoing mail server Incoming mail server op mail yahoo de smtp mail yahoo de User name Special features User name Uses SMTP authentication To make use of POP3 and SMTP you first need to register with Yahoo directly Free access via POP3 and SMTP is only possible for mail accounts registered with Yahoo Deutschland i e the domain of your Yahoo Address is yahoo de Addresses in the yahoo com domain come at an extra charge Details not guaranteed This information should be verified by the service providers Available online services registration necessary are listed below T Online Incoming mail server pop t online de Outgoing mail server User name mailto t online de Any Special features Freenet Incoming mail server Any user name and password are permissible these parameters can even be left out com pletely provided that you have logged in via T Online mx freenet de POP3 and IMAP User name Outgoing mail server mx freenet de username freenet de Special features Uses SMTP authentication Details not guaranteed This information should be verified by the service providers 8 5 5 System Time The System time indicates the current time in
10. Download The download function makes it possible to view and save data locally C00410334 01 53 8 Working with ComLynx Weblogger Danfoss 54 Download Plant data Plant sum Data Timestamp Power Income today Measured income Irradiation Irradiation income today Period 2007 02 26 to 2007 04 13 Record size 396 KB Inverter details Timestamp Serial number Power Income today Temperature Grid voltage Grid current Data Frequency PV voltage 1 PV current 1 PV voltage 2 PV current 2 PV voltage 3 PV current 3 Operating mode DC Modules Event Module Period 2007 02 26 to 2007 04 15 Record size 6 7 MB Sensor data Data Timestamp Serial number Environment temperature Module temperature Irradiation Income today Power Period 2007 02 26 to 2007 04 15 Record size 505 KB Plant events Data Timestamp Event type Event Period 2007 02 26 to 2007 04 13 Record size 858 KB Illustration 8 43 Overview of Available Download Records Plant sum Contains values for the total income today power recording time stamp as well as irradiation and irradiation income today Inverter Details Provides detailed information on each selected inverter Sensor Data Contains detailed information and recording time stamp of the sensors on each selected value Plant events Lists events details warnings and errors The download page displays all the information available in ComLynx Web
11. Power 3394 W Income today 10 706 kwh Temperature 72 C Grid voltage 735 V Grid current 15 159 4 Frequency 50 03 Hz P voltage 1 304 7 V P currentl 46 201 4 P voltage 2 284 7 V P current 2 6 701 4 P voltage 3 0 P current3 Operating mode GRID DC Modules 2 Event OK Module Illustration 8 32 Inverter Status ComLynx Weblogger registers the inverter data described below Parameter Unit Description Name Inverter description Time stamp dd mm yyyy hh mm ss __ Time stamp Serial number The serial number of the current inverter Power W Current production 0 65 kW Income today Wh Daily yield 0 4000 MWh Temperature eC Internal inverter temperature 120 120 C Grid voltage Grid voltage 0 250 V Grid current mA Grid input current 0 65 A Frequency Grid frequency 0 100 00 Hz PV voltage 1 V DC module 1 input voltage 0 6500 0 V PV current 1 DC module 1 input current 0 65 A PV voltage 2 V DC module 2 input voltage 0 0 65 A PV current 2 DC module 2 input current 0 6500 0 V PV voltage 3 V DC module 3 input voltage 0 0 6500 0 V 3 gt PV current 3 Operation mode DC module 3 input current 0 65 A Operating mode GRID DC module Inverter type 0 255 Event Error code 0 255 Module Error code of delivering module 0 255 Note Z Additional information on inverters is provided in the related manufacturer s manual Status
12. The time stamp cannot be deactivated Click on Downlfoad to start the download process Download can take a few seconds As soon as it is complete a separate window appears for opening or saving the file This window can be used to save the data file to your local hard disk or view Open it directly with the associated program Note Z File download might be prevented by pop up blockers in Internet Explorer Firefox and or firewall software Note the respective program supplier s usage instructions and options C00410334 01 55 9 Technical Data Danfoss 9 Technical Data ComLynx Weblogger Processor Industrial PC CPU AMD SC520 133 MHz Flash BIOS 64 MB RAM RTC Main Memory 64 MB RAM Operating System Linux COM Ports 1x RS485 on terminal strip 1x RS485 RJ45 double socket Interfaces LAN Ethernet 10 100 full duplex Modem or GSM connection SUB D9 EasyLan Signals Internal loudspeaker LEDs for indicating events 7 green 1 red 3 LEDs on the multipoint connector Data Storage Compact Flash type I adapter inside the housing for operating system and data storage Housing 2 part non ventilated metal housing for carrierrail mounting IP20 Weight 800g net without accessories and cable Environment humidity Indoors Switch cabinet Operating Tempera Minimum 0 50 C ture Dimensions 175mm x 155 mm x 45 mm W x H xD including rear carrier rail adapter and multipo
13. and diagrams automatic distribution via e mail HTTP Internet Display of current plant status instantaneous values Download of measurement data for further processing Dynamic language switchover for users ComLynx Weblogger is operated fully via a web browser like the Internet Explorer or Firefox One decisive advantage of the ComLynx Weblogger System is that the system s intelligence is within the ComLynx Weblogger and therefore directly at the plant This is what makes independent on site monitoring possible The diagram below provides an overview of system components C00410334 01 5 3 ComLynx Weblogger Description Danfets Acquisition of parameters such s as AC DC of PV fields as an option for further investigation in case of issues s a Inverter communication g Direct monitoring of inverter data up to 50 inverters More inverter Automatic dispatch of Yield reports Event notifications p Email Direct control via web browser _ Z Illustration 3 1 System Overview 3 2 Scope of Delivery Scope of delivery for the ComLynx Weblogger includes ComLynx Weblogger Terminator plug for RS485 inverter bus 256MB Compact Flash memory card installed in the device with pre configured ComLynx Weblogger software Plug in power supply unit Cable length 1 5 m Input 100 240VAC Output 12 V 2A 75 x 43 x 34 mm pre mounted on the terminal strip Crossli
14. configuration modified 2006 07 28 14 00 02 Automatic network scan was performed 2006 07 28 09 41 35 Plant details configuration modified 2006 07 28 14 00 05 Automatic network scan was performed 2006 07 28 10 00 06 Automatic network scan was performed 2006 07 28 14 00 02 Automatic network scan was performed Illustration 8 35 Overview of Monitoring Log Clicking on Back invokes the monitoring overview again Event Notification Monitoring Editing Functions Several icons are available for editing the event notification Notifications can either be activated deactivated directly in the overview using the symbols or in the settings When you move the mouse over any one of the icons a tool tip describing the related function appears Bi Change settings message activation intervals e mail transmission Activate alarm only visible with a deactivated alarm Deactivate alarm only visible with an activated alarm Edit Settings Notification settings e mail dispatch can be configured here C00410334 01 268 8 Working with ComLynx Weblogger Configuration System event Notification active Description General system events such as reboot Frequency daily BA Recipient alarm contact Alarm C Email My email notification Illustration 8 36 Reporting of Events and Event Groups via E mail Under Description you can edit the event group s short description clicking on Save applies the changes
15. immediately to the overview The event group s name cannot be changed Notification can be activated by marking the corresponding check box the notification interval can be specified in the Frequency field These values depend on the event group and the reaction holding time configured in 8 5 10 The reaction period refers to ComLynx Weblogger s alarm time the set interval ap plies exclusively to the event report A Recipient can be configured as in 8 5 7 message recipients Permissible intervals for event groups are listed below Event Immediately Immediately Hourly Daily Weekly Group without re and hourly minder reminder Configura X X X tion events System X X X events Inverter X X events 1 No daily X 2 X ield Low daily X 2 X yield Inverter fail X 2 X ure Communica X X tion error System mes X X sage 1 Reaction holding time 2 Daily check at 6 pm reports are issued later C00410334 01 47 8 Working with ComLynx Weblogger Danfoss 8 7 2 48 Immediately Immediately following a reaction period if necessary no reminder without reminder of a currently registered event is issued after that Immediately Immediately followed by hourly reminders as long as the event is and hourly reminder still registered Hourly On every hour a check is made as to whether events in the event group occurred in the previous hour New event
16. low levels of solar irradiation If the plant s total income falls short of the minimum level no energy comparison or alarming takes place Installed peak power The maximum power must be entered manually in the corre sponding field Wp A value of 0 deactivates monitoring of the inverter s income The maximum power can be set individually for each inverter in 8 5 11 Configuration Inverters Evaluation is performed as described below Each inverter s daily income is divided by the maximum power of its installed solar modules An inverter s relative income is determined as follows Relative income Energy per day kWh installed power kWp The relative income is compared with the remaining inverters output If the percentage deviation exceeds the set minimum value an alarm is issued An income comparison is only performed if two or more inverters are active Reaction holding time Additionally the time interval to alarm issue reaction holding time can be set for the inverters immediately alarm issued immediately after event It is possible to send alarms via e mail For that purpose a message recipient 8 5 7 needs to be created and activated Settings for monitoring e mails are described in 8 7 C00410334 01 Danfoss 8 Working with ComLynx Weblogger False alarms due to seasonal and weather related factors such as snowfall and twi light are not to be ruled out 8 5 11 Inverter Under In
17. 1 1 Contents Danfoss Language Options O O U U f 25 Configuration i l f ae C f 26 Network x L 26 Modem o C 28 E mail Service 2 I LI 29 Well known Free mail and Online Services I C r r r r 30 System Time 8 o t t 1 31 Passwords 33 Message Recipient Y Y O 33 Plant Details x r 35 Webportal O I t t 36 PV Plant 37 Inverter C r Y 5 39 SEMSOTS 7 4444 C U U U 40 System Language 4 4 t L r C 42 Plant Status x r 43 Monitoring 8 x tC C 45 Event Notification Monitoring Editing Functions 46 E mail Messages x I 88 Ia C 48 Notification of Alarm C Ct C C f f f f 49 Reports 8 t t r C C 49 Reports Editing Functions x tr r r rr f 51 E mail Messages x 8 r rr U 53 Download x 8 r tl 53 9 Technical Data YO 56 10 Disposal le l al a CL l lL C C 57 11 Declaration of Conformity 2 o fl 58 2 C00410334 01 2 1 About This Manual 1 About This Manual This manual provides detailed product information and instructions on how to u
18. 6 09 18 14 16 47 2006 09 18 14 17 02 2006 09 18 14 50 02 2006 09 18 14 50 09 Illustration 8 40 Report Reports Daily yield of inverters Daily overview of each inverter yield 2006 v 12 v ol x kHh Inverter2 s Invertert Inverter3 Events System restarted at 2006 09 18 11 38 02 Inverter SN 44440QH4905 found at address 1 1 2 Inverter SN 22220QH2005 found at address 1 1 33 Inverter 444400H4905 AC Module reports error U GRID Inverter 44440QH4905 configuration modified Inverter 22220QH2005 configuration modified Inverter 44440QH4905 configuration modified Inverter 22220QH2005 configuration modified Inverter 444400H4905 AC Module reports error U GRID Automatic network scan was performed Inverter 44440QH4905 configuration modified Inverter 22220QH2005 configuration modified Communication lost to Inverter 44440QH4905 Communication lost to Inverter 22220QH2005 8 8 1 Reports Editing Functions As in the monitoring section several icons are available for editing the report groups here Noti fications can either be activated deactivated directly in the overview using the symbols or in the settings When you move the mouse over any one of the icons a tool tip describing the related function appears Change settings message activation intervals e mail transmission Activate evaluation only visible with a deactivated evaluation 3 Deactivate evaluation only visible with an activate
19. 92 168 2 1 File Edit View Favorites Tools Help Q Back f x F g P Search r Favorites Address http 192 168 2 1 Illustration 6 13 IP Entry Internet Explorers C00410334 01 21 7 Mounting 2 7 1 Mounting The ComLynx Weblogger is intended for mounting indoors or in switch cabinets It may be moun ted horizontally or in a suspended state with connections facing downwards on mounting rails or on a wall with the brackets provided see below Attention Like all other electronic devices ComLynx Weblogger needs to be protected against moisture especially condensation Illustration 7 1 Wall Bracket The ComLynx Weblogger is hung on the mounting bracket by locking the screws on the rear of the device into the sockets on the bracket When attaching the device care should be taken that the cable can be easily attached from below avoiding strain on the cable Attention The unit should be firmly attached to a wall using raw plugs to avoid risk of falling and being damaged To avoid damage to the device the wall bracket should be fixed using raw plugs Mounting outdoors is only permissible inside suitable switch cabinets protection level IP65 Connection or removal of any cables wires should only be done when the device is switched off 22 C00410334 01 Danfoss 8 Working with ComLynx Weblogger 8 Working with ComLynx Weblogger 8 1 Working with ComLynx Weblogger
20. ComLynx Weblogger This value can be adjusted manually or synchronised via NTP time server systems Although an NTP time server is set as default it can be modified individually Ad dresses can be found on the Internet NTP Network Time Protocol standard for synchronising clocks in computerised C00410334 01 8 Working with ComLynx Weblogger 31 8 Working with ComLynx Weblogger Danfoss 32 Configuration System time System time Dienstag 27 Februar 2007 15 36 38 Time zone GMT 01 00 Amsterdam Berlin Berne Rome Stockholm Paris Server time replication enabled ntp1 ptb de Edit Illustration 8 11 System Time Information System time configuration can be changed with ea t Admin access is necessary See Chapter 8 3 1 Configuration System time Edit Date 2006 11 30 Time 14 FG Time zane GMT 01 00 Amsterdam Berlin Berne Rome Stackholm Paris Server time replikation activate Time server ntpi ptb de Foniy reoticated with an active moden Connection Save Cancel Illustration 8 12 Editing System Time Manual adjustment of the Date and Time is directly possible Attention Use caution when changing system time A time difference of more than 10 mi nutes can lead to problems with the data which has already been recorded Additionally you can set a 7ime zone although it does not influence the system time Per mitting a dis
21. Lynx Weblogger 268 Parameter Description Address 81 Name ComLynx Weblogger Group Here you can individually define groups The sensor module is dis played in accordance with their group affiliation Status By marking this check box the sensor can be set to Active and scanned accordingly by the system status monitor Inactive sensors are auto matically hidden from view External temperature Gives an Offset delta value for the correction of the external temper ature Module temperature Gives an Offset delta value for the correction of module temperature Irradiance sensor Selection of sensor type The calibration value indicates the voltage generated by the sensor when an irradiance of exactly 1000 W m is attained This value is nor mally noted on the irradiance sensor The default setting is 75 mV Pulse counter Indicates the number of pulses generated by the yield counter per kWh The default value here is 1000 i e the yield count increases by 1 kWh every 1000 pulses Power transformer The calibration value indicates the maximum plant power to which 20mA corresponds on the output 8 5 13 System Language The Standard language of the ComLynx Weblogger is set to English on production but can be individually set for each system Configuration System language System language German Edit Illustration 8 29 System Language The language option can be changed with Ea t Admin access is nece
22. MAKING MODERN LIVING POSSIBLE ComLynx Weblogger User Manual DANFOSS SOLAR INVERTERS Danfoss Contents Contents 1 About This Manual gt gt eee 3 2 Safety Instructions 2 ee 4 3 ComLynx Weblogger Description O gt 5 System Overview 5 Scope of Delivery x C t C C C 6 Recommended Accessories I I 44 r 7 Connections O V Y C 7 Terminal Strip 8 poley x 2 r r f 8 Signals and Operational Indicators on the Device 8 LED Display on Top of the Device 8 LED onthe Terminal Strip x 8 Audio Signals 9 Compact Flash Memory Card 2 4 4 4 4 r Y Y U 9 4 Description of ComLynx Sensor Interface 10 System Overview _ 4 Y U 10 Sensors i i i Y C 10 Data Bus and Power Supply x C r r U f 11 5 First Installation 20 12 6 Connection and Start up sss 15 Connection via LAN Interface or Modem 15 Connection to the Inverter Network 15 Electrical Mains Connection U U r r YY f f 16 Switchon r Y Y C 16 ComLynx Weblogger Connections 7 I 4 4 4 Y 16 Via Direct Connection 2 I 4 444 r C fff f 16 Network Connection 8 rr U U U 17 Via Remote Access Analog ISDN GSM etc 7 4 4 f f rf 17 7 Mounting C 22 Mounting a 22 8 Working with ComLynx Weblogger i o 23 Working with ComLynx Weblogger eee 23 User Rights Access Rights J 444 r f 23 Web Interface 23 Sub menu Editing Functions 25 C00410334 0
23. access is that the Dial Out Switch is in the on position This switch can be found on the rear of ComLynx Weblogger unit see Chapter 3 4 The current position of the switch can be seen on the overview of the modem configuration To avoid unforeseen costs it is advised to deactivate the internet access as soon as it is no longer required If Internet connection is deactivated no messages can be sent Standard modem settings for Internet connection via MSN Dial in number 0193670 Login msn easysurfer eco de Password msn Dial in number for extensions Additional modem commands ATX3 Dial in number 00193670 8 5 3 E mail Service Under E mail service you specify mail server settings for exchanging e mails Parameters here include SMTP server login password and sender address and authentication type Configuration Email SMTP server smtp mail com Login max mustermann musteradresse com Password Sender muster musteradresse com SMTP authentication enabled Edit Illustration 8 9 Overview of E mail Service C00410334 01 29 8 Working with ComLynx Weblogger Danfoss 8 5 4 30 E mail service configuration can be changed with edit Admin access is necessary See Chapter 8 3 1 Configuration Email Edit SMTP server smtp mail com Login myname myaddress com Password coocoo Sender address myname myaddress com SMTP authentication switch on
24. ax Mustermann musteradresse com E mail addresses are allocated by the provider or online services such as free mail see Chapter 8 5 4 Status Via activating deactivating the checkbox the message recipient can be set to active inactive Note Recipients already configured can be deactivated temporarily e g for vacation periods Recipient s language Language of the e mails to be sent to the recipient Mandatory field Short E mail Electronic sending receiving of messages Unlike in Emails important information is only submitted in the subject of the message This allows the forwarding of the message as SMS text message to a mobile phone Example Day yield Plant name 2007 03 20 34 340 kWh Settings for sending a short e mail can be found in type E mail Alarm Contact To connect sirens and lamps For this the alarm contact has to be connected to the relay output of the ComLynx Weblogger see Chapter 3 4 34 C00410334 01 Danfoss 8 Working with ComLynx Weblogger Configuration Message recipient Edit Type alarm contact Name Alarm Alarming period Status active Illustration 8 17 New Alarm Contact Parameter Description Type Alarm contact Name Recipient s name e g 10 minute alarm Alarm Period The duration of the connected sirens lamps can be set here The alarm contact will switch off automatically after the chosen dura tion or can be switched off manually with Alarm C
25. ccess via modem no preliminary IP settings are necessary at the PC Generally for the first use of the ComLynx Weblogger it is necessary to identify inverters This can be done via the Web interface under Configuration Inverter see Chapter 8 5 11 6 5 1 Via Direct Connection A connection must be established to a LAN interface of a local PC via a crosslink cable see Chapter 6 Enter the IP address into a web browser to open the ComLynx Weblogger start page This is the IP address of the device 192 168 1 190 in delivery status or the IP address allocated by an administrator 16 C00410334 01 Panett 6 Connection and Start up File Edit View Favorites Tools Help QO Back v x B g P Search S f Favorites Address http 192 168 190 Illustration 6 5 IP in Delivery Status Entry into Web Browser For faster access the IP address can be saved in Favourites of your chosen web browser 6 5 2 Network Connection ComLynx Weblogger must be connected to the network via a patch cable and after connection of the network cable can be invoked by entering the IP address in a Web browser as with direct connection The address used is the IP address of the device 192 168 1 190 in delivery status or the address configured in the initial installation see Chapter 5 6 5 3 Via Remote Access Analog ISDN GSM etc If ComLynx Weblogger is to be used with a modem a connection between the PC and ComLy
26. d evaluation C00410334 01 51 8 Working with ComLynx Weblogger Danfoss Edit Settings Notification options e mail dispatch can be configured here Configuration Daily power of entire plant Notification IY active Description Daily power of plant Frequency daily v Recipient Email My email notification Save Cancel Illustration 8 41 Reporting of Evaluations via E mail Under Description you can edit the event group s short description clicking on Save applies the changes immediately to the overview The name of the event group cannot be changed Notification can be activated by marking the corresponding check box the notification interval can be specified in the Frequency field Recipients can be configured as in 8 5 7 message recipients Permissible intervals for report groups are listed below Evaluation Group Hourly Daily Weekly Daily power X X Daily yield X X Monthly yield X X Yearly yield X Hourly On every hour an updated report together with occurred events is is sued Daily Every day at 00 00 hours an updated report together with occurred events is issued Weekly Every Monday at 00 00 hours an updated report together with occurred events is issued Activate Deactivate Notification pa Activate at De activate Clicking on the relevant icon will activate or de activate the alarm Checking or unchecking
27. details on sensors connected to the ComLynx Sensor Interface can be viewed by clicking on Sensors in the navigation menu 44 C00410334 01 Danfoss 8 Working with ComLynx Weblogger Plant state Sensors System time 2007 04 16 14 37 06 Name Sensor Interface Timestamp 2007 04 16 14 37 03 Serial number 81 Environment temperature C Module temperature Irradiation W m Income today 0 000 kWh Power W Illustration 8 33 Sensor Status 8 7 Monitoring The monitoring menu provides an overview of all system events according to category All events are listed in detail and can be configured individually for cyclical notification Monitoring Configuration events Configuration changes new message recipient System event General system events such as reboot CI System details Advice error messages Inverter events Events reported by inverter GI No daily yield Inverter without daily yield Low daily yield Yield deviation of the inverter from the averaged daily plant yield too high Inverter failure Inverter wasn t reachable ALL DAY T Illustration 8 34 Overview of Monitoring Configuration Events Provides information on modified configurations newly created and modified message recipients deactivated alarms and re starts Example Message recipient my recipient myaddress com was added System Events Provides information such as system starts Internet access e
28. for connecti i us e g for cting a mad GND Paay kam Dis sensor module GND l l B COM3 RS485 in Optional interface e g for con O A terface necting a large display O pe o GND D IN1 For connecting an error detector gt Q IN1 Floating input switching voltage 12 24 GND VDC OK1 IN1 IN1 For outputting error messages Relay output max switching voltage 48 OK1 OK1 VDC OK1 3 5 Signals and Operational Indicators on the Device 3 5 1 LED Display on Top of the Device 1 Inverter event 2 Stand by system operational 3 Inverter communication 4to 8 Current power sum The power sum of the LED display will be calculated on basis of the max input value of the inverters 100 per numbers of LED Since the so far indicated unit power is very low increased display values may occur initially In order to prevent this the max input power can be entered manually for each inverter see Chapter 8 5 10 U In order to check the functioning of the LED display all LEDs will light briefly on D start up 3 5 2 LED on the Terminal Strip Data Yellow on Modem communication active Internet Red on Modem can establish link independently internet dial in Power Green on Power supply OK Weblogger via modem gt Dial Out LED on Active dial out results in telecommuni i The Dial Out switch is used to enable disable independent dial out by ComLynx cat
29. formation Settings such as host name system name see Chapter 8 5 1 and system time chapter 8 5 5 can be made in the related sub menus Details are provided in the subsequent chapters Information on hardware and memory is updated automatically by ComLynx Weblogger and can not be edited If no system or component configuration is desired skip the following items and continue directly from plant status Chapter 8 6 8 5 1 Network Under Wetwork settings such as host name domain name IP address broadcast address subnet mask standard gateway and DNS server are predefined 26 C00410334 01 268 8 Working with ComLynx Weblogger Configuration Network Settings via DHCP disabled Host name Domain name IP address 192 168 1 190 Broadcast address Subnet mask 255 255 255 0 Standard gateway ONS server 192 76 144 66 Edit Illustration 8 5 Overview of Network Information Options here include own settings default or DHCP settings to be requested from the LAN ad ministrator DHCP settings employ different IP addresses DHCP Dynamic Host Configuration Protocol dynamic allocation of IP addresses To avoid serious connectivity problems with ComLynx Weblogger these parameters should only be edited in consultation with your network administrator Network configuration can be changed with edit Admin access necessary see Chapter 8 3 1 Configuration Network Edit
30. h setting Illustration 8 7 Overview of Modem Information Modem configuration can be changed with edit Admin access necessary see Chapter 8 3 1 Configuration Modem Edit Modem type Standard modem GSM modem Baud rate 57600 Additional modern configuration PIN if using GSM must be entered when using a GSM modem otherwise no connection will be established Access number Ow0192658 Login name MSN Password eee Number of rings 2 until call acceptance Illustration 8 8 Editing Modem Parameters 28 C00410334 01 268 8 Working with ComLynx Weblogger The following settings can be made here Parameter Description Modem type Type of the employed modem Baud rate Maximum transmission rate of the connected modem Additional modem com Configuration command for modem operation with software flow mand control PIN for GSM GSM PIN code This code can be requested from the provider If a GSM modem is being used this code is a prerequisite for estab lishing connections Access number Number of the target computer provider e g 0w0192658 The w generates a pause during dialling If extensions are in use do not forget to specify an exchange num ber This number is usually 0 as shown in the example above Login name User name e g MSN Password Password Number of rings Number of rings until the modem automatically takes the call A prerequisite for Internet
31. int connector Alarm Contact Potential free Output max 48VDC Electricity Supply 12 24 VDC power supply typically 5 7 W via an external plug in power supply unit 56 C00410334 01 Danfi 10 Disposal 10 Disposal Disposal of Waste Equipment by Users in Private Households in the European Union This symbol on the product or on its packaging indicates that this product must not be dis posed of with your other household waste Instead it is your responsibility to dispose of your waste equipment by handing it over to a designated collection point for the recycling of waste electrical and electronic equipment The separate collection and recycling of your waste equipment at the time of disposal will help to conserve natural resources and ensure that it is recycled in a manner that protects human health and the environment For more information about where you can drop off your waste equipment for recycling please contact your local city office your household waste disposal service or the shop where you purchased the product C00410334 01 57 11 Declaration of Conformity Danfets 11 Declaration of Conformity 58 2 2 Danfoss Solar Inverters A S Jyllandsgade 28 DK 6400 S nderborg Denmark CVR no 26 84 36 26 Tel 45 7488 1300 Fax 45 7488 1301 E mail solar inverters danfoss com Homepage www solar inverters danfoss com EU DECLARATION OF CONFORMITY Danfoss Solar Inverters A S Jyllandsgade 28
32. ion charges for the operator 8 C00410334 01 a 3 ComLynx Weblogger Description 3 5 3 Audio Signals ComLynx Weblogger emits an audio signal to acknowledge that power is on Apart from that an audio signal is only used in case of an error as on a PC 3 6 Compact Flash Memory Card A 256 MB Compact Flash memory card is used as a storage medium by ComLynx Weblogger Approximately 50 MB of memory are needed by the system ComLynx Weblogger does not func tion without an installed Compact Flash memory card Attention The internally installed Compact Flash memory card should only be changed by an authorised dealer C00410334 01 9 4 Description of ComLynx Sensor Interface Danfi 4 Description of ComLynx Sensor Interface 4 1 System Overview Weather climate and environmental data also serve to qualitatively assess a solar plant s features To measure variables such as directional irradiance module temperature and input electrical en ergy optional sensors can be installed on the PV system and scanned tested by an external analogue digital converter called ComLynx Sensor Interface This sensor module is able to register 1x 0 150mV 2x PT1000 1x pulse and 1x 0 20mA thus permitting measurements of environment data module temperature irradiance and power through transformer RnR ee PET TTT IE sip it ik ie it it if ik it ie it AN PT1000 Z Environmental j XQ te
33. logger in the following order Logged data fixed entries in the case of events Period the time period in which data has been logged Record size KB or MB the size of the file containing the logged data KB or MB Clicking on the header of a log invokes the corresponding download form This page again displays additional details on the log type Depending on the selected type the download form displays a list comprising data columns Download Plant summary pata Timestamp Power Income today Measured income Irradiation Irradiation income today Period 2006 11 20 to 2006 12 01 Record size 79 KB from 2008 s a4 20 File type Cl GZIP compressed Download Cancel Illustration 8 44 Download Form Example Plant Summary C00410334 01 268 8 Working with ComLynx Weblogger The following download criteria can be defined Desired period in days All data records logged within this period are downloaded Desired data columns This does not apply to the plant summary which is downloaded in a fixed data format Desired file format A choice of txt text csv comma separated values and xml XML file is available here Additional choice of GZIP compression which allows a quicker data download e g when dealing with large data volumes or a slow modem connection Note Z Modern browsers e g Internet Explorer from Version 5 0 decompress GZIP files automati cally
34. mended Uses SMTP authentication or POP3 before SMTP depending on your account configuration IMAP is only available at ProMail and TopMail rates Google mail Incoming mail server pop googlemail com SSL port 995 Outgoing mail server smtp googlemail com SSL port 465 or 587 User name username googlemail com Uses SMTP authentication POP3 and SMTP are SSL encrypted Special features SMTP server runs on port 465 or 587 POP3 server runs on port 995 standard port for POP3 via SSL C00410334 01 Hotmail 2 2 Lycos mail This e mail provider does not offer any POP3 or SMTP services An account requiring payment can be used to access mail via HTTP mail protocol in Outlook and or Outlook Express The HTTP mail address is http services msn com svcs hotmail httpmail as Incoming mail server Outgoing mail server op premiummail lycos de smtp premiummail lycos de User name Special features Complete Lycos e mail address Uses SMTP authentication POP3 and SMTP are only available at extra charge To avoid payment you can access your Lycos account via HTTP mail As a registered user of The Bat e mail program however you can use POP3 and SMTP freeof charge In this case though you will receive e mail advertisements from Lycos partners The HTTP mail address is http webdav lycos de httpmail as WEB DE FreeMail Incoming mail server POP3
35. mperature PT1000 Power Transformer kos Pulse counter itt pulse kWh Directed irradiation Inverter data bus Up to 50 inverter Sensor Interface Analogue digital converter EasyLan field bus Illustration 4 1 System with a Connected ComLynx Sensor Interface 4 2 Sensors 10 The following sensors may be installed via the ComLynx Sensor Interface Irradiation sensor 0 150mV mono polycrystalline or amorphous With or without temperature measurement Module temperature sensor PT1000 C00410334 01 a 4 Description of ComLynx Sensor Interface Environment temperature sensor PT1000 Impulse generator Digital Input Passive 12V 24V Transformer for power 0 20 mA output proportionally to the power The correct function of additional sensors cannot be guaranteed 4 3 Data Bus and Power Supply To connect the ComLynx Sensor Interface the data bus and power supply must be connected to ComLynx Weblogger Uin 12 24v 01 D Illustration 4 2 ComLynx Sensor Interface Connection The GND 04 EasyLan 03 data bus and Uin 12 24V 01 power supply must be routed to the corresponding terminals PIN on the strip see also to Chapter 3 4 1 For the connection to a separate plug in power supply unit see the Quick Guide of the ComLynx Sensor Interface The irradiation sensor cable should generally NOT be extended as this may lead to gross errors in measuremen
36. nk Ethernet PC connection cable 2 m Assembly kit Assembly adapter hat rail clamp screw set 3 screws and dowels for fastening CD with manuals in English German French Spanish and Italian Quick Guide in English German French Spanish and Italian C00410334 01 Danfoss 3 ComLynx Weblogger Description 3 3 Recommended Accessories Modem network e Analogue DEVELO Microlink 56k i ISDN DEVELO Microlink ISDN i GSM Siemens MC35i Terminal WLAN D Link Netgear ComLynx Sensor Interface The connection of Sensors to the ComLynx Weblogger can only be achieved via the ComLynx Sensor Interface The sensor module must be ordered additionally from the manufacturer 3 4 Connections 3 4 1 Connections ComLynx Weblogger is equipped with the connections described below Illustration 3 2 ComLynx Weblogger connections 1 Power supply terminal strip EasyLan field bus RS485 data interface 1 relay output for event message contact and 1 floating input 2 Serial interface for modem 3 3 LEDs for indicating operational statuses red yellow green 4 Dial out and function switches function switch not yet assigned 5 RS485 data interface RJ45 double socket for inverter connection 6 LAN Ethernet interface C00410334 01 7 3 ComLynx Weblogger Description Danfoss 3 4 2 Terminal Strip 8 pole PIN Function Description GND GND 12 24 V Voltage supply i EasyLan Field bus e g
37. nt picture A picture can be loaded optional see Chapter 8 5 8 Plant information This item provides prior configured information such as a short description and operator details A individually editing is possible see Chapter 8 5 8 Plant status This item indicates the time stamp date time of the last event clicking on it directly invokes the monitoring page Also shown is a status light indicating the PV plant s current state Green Plant operations OK Yellow One inverter is faulty no communication no network feed Red At least 30 of all inverters are faulty no communication no network feed Alarm confirmation The alarm confirmation is to deactivate an alarm contact which is only indicated with an active relay Alarm details can be found in Monitoring Chapter 8 6 activate deactivate alarm Current plant power A line diagram indicates the PV plant s current daily power The power of individual inverters are displayed along a time axis Evaluation details are provided in 8 7 If an irradiation sensor has been connected to ComLynx Weblogger the irradiance is also indica ted C00410334 01 8 3 1 268 8 Working with ComLynx Weblogger H H n2 140 1200 ize 1000 a 800 D on 4 400 20 200 0 E i i i 0 4 00 7 00 10 00 13 00 16 00 19 00 22 00 29 Novenber 2886 Illustration 8 3 Plant Power with Radiance Sensor Note Z Pictures reaching a size of 200 x 200 pixels or more can be pri
38. nted out by clicking on the corresponding toolbar icon if active refer to the description of the toolbar in the user manual of Internet Explorer The left part of the web interface shows the main menu from where all submenus can be invoked including Plant status Plant status inverter power groups total power of the PV plant current sensor values etc Monitoring Events system inverter configuration and general system failures etc Reporting Graphic reports power yield etc with optional messaging Configuration System and component configuration default settings apply during initial commissioning Download Data transfer to PC TXT CSV XML Details on individual functions are provided in the subsequent chapters Sub menu Editing Functions Settings and changes are performed in the sub menu of the selected function Click on Edit to enter the required settings If you have not yet logged in as an authorised user you have to register as administrator Setting changes are performed exclusively at the administrator level see Chapter 8 2 Click on Cance to discard new data and restore the previous settings Click on Save to save new data and overwrite the previous settings Changes to the system and component configuration are logged as events by the monitoring function see Chapter 8 6 In both cases the editing window then closes automatically click on Edit once again to perform fur
39. nter a phone number Hew Connection Wizard Phone Number to Dial What is your ISP s phone number Type the phone number below Phone number You might need to include a 1 or the area code or both If you are not sure you need the extra numbers dial the phone number on your telephone If you hear a modem sound the number dialed is correct Illustration 6 11 Entry of a Phone Number Internet server Next gt User name and password are not necessary Finish creation of the connection The number can now be dialed Connect Dial up Connection User name Password Save this user name and password for the following users Dial v Illustration 6 12 Connection Establishment If an ISDN modem is used in conjunction with a normal modem on ComLynx Weblogger s side appropriate drivers need to be installed for modem emulation In the case of AVM Fritz cards including USB versions this option must be post installed from the AVM software CD refer to AVM ISDN analogue modem V32 BIS If an ISDN modem is used in conjunction with another ISDN modem on the ComLynx Weblogger s side both sides must be linked via an X 75 operating mode However in this case communication via normal modems is not possible 20 C00410334 01 Panett 6 Connection and Start up When the network connection is configured and set the ComLynx Weblogger start page can be opened via a modem with the IP http 1
40. nx Weblogger via the telephone network must be established Start gt Control panel gt Network connections gt Create new connection Connect to the Internet Hew Connection Wizard Network Connection Type What do you want to do Connect to the Internet so you can browse the Web and read email Connect to the network at my workplace Connect to a business network using dial up or VPN so you can work from home a field office or another location Set up a home or small office network Connect to an existing home or small office network or set up a new one Set up an advanced connection Connect directly to another computer using your serial parallel or infrared port or set up this computer so that other computers can connect to it Illustration 6 6 Connection to the Internet C00410334 01 17 6 Connection and Start up a Setup up my connection manually Hew Connection Wizard Getting Ready The wizard is preparing to set up your Internet connection How do you want to connect to the Internet Choose from a list of Internet service providers ISPs For a dial up connection you will need your account name password and a phone number for your ISP For a broadband account you won t need a phone number Use the CD I got from an ISP Illustration 6 7 Manual Connection Setup Connect using a dial up modem Hew Connection Wizard Internet Connection Ho
41. onfirmation 8 6 3 Status Setting or removing the check mark will activate deactivate the alarm contact Click on Edit Figure 8 5 to enter new settings and overwrite old ones see Chapter 8 3 1 this does not apply to the message recipient type After being saved once the message recipient type can no longer be changed For this purpose you need to create a new message recipient 8 5 8 Plant Details Under Plant details you can define and modify settings for the main page Apart from creating a plant picture you can specify a name description owner and other plant related details Configuration Plant information Show on Welcome page F Plant picture choose new picture Browse recommended size 500x300 pixels format IPG Plant information Name Web logger LAB mandatory field Description Datalogger Owner Danfoss A S Illustration 8 18 Editing the Main Page The plant picture can be activated deactivated via a checkbox To enable graphic display the checkbox Show on welcome page needs to be marked and an image file needs to be uploaded C00410334 01 35 8 Working with ComLynx Weblogger 268 Click on Browse and then on Open to upload a locally saved graphics file complying with the prerequisites mentioned here Click on Save to display the image on the main page If an image does not comply with the graphics prerequisites
42. play of locations within the selected time zone this option relies on the time value entered beforehand Defined time zones are listed below Time Zone Cities excerpt GMT Greenwich Mean GMT Casablanca Monrovia Dublin Edinburgh Lisbon UT Universal London UTC Universal Coordinated WET Western European CET Central European GMT 01 00 Amsterdam Berlin Bern Rome Stockholm Paris EET Eastern European GMT 02 00 Athens Istanbul Minsk Cairo Jerusalem CAT Central Africa Time SAST South Africa Standard Time EAT East African GMT 03 00 BT Baghdad Baghdad Moscow Nairobi MSK Moscow Time GMT 12 00 To synchronise with the time server check the server time replication option Once a modem connection is active the system time is compared with the time server s value C00410334 01 2 2 8 Working with ComLynx Weblogger Time server synchronisation depends on connection settings and the conditions listed below Time Connection Condition 5 am daily Network con Correct DNS and gateway settings see Chapter 8 4 1 nection After successful Modem link connection set up Connection needs to be established by ComLynx Weblogger Switchover to and from daylight savings takes place automatically 8 5 6 Passwords Under Passwords you manage passwords for system administration The administrator s pass word can be changed here Configuration Password
43. s Administrator Edit Illustration 8 13 Passwords Time Information Password configuration can be changed with alt Admin access is necessary See Chapter 8 3 1 Configuration Passwords Edit Username Administrator Password Password confirmation Illustration 8 14 Editing Password The password must have between 6 and 16 characters 8 5 7 Message Recipient Under Message recipient you manage the recipients of reports and events monitoring Configuration Message recipient Name Type Status My email notification Email active Edit Alarm alarm contact active Edit New Illustration 8 15 Overview of Message Recipients Click on Wew to create a new recipient set the recipient status to Active Inactive as required C00410334 01 33 8 Working with ComLynx Weblogger Danfoss Individual dispatch options can be edited in the Monitoring Chapter 8 6 1 and Reports Chapter 8 7 sections There are various types of message recipients E mail Electronic sending receipt of messages Configuration Message recipient Edit Type Email u v Narne My ernail notification Email address myname myaddress com Status active Recipient Language English Illustration 8 16 New E mail Recipient The following settings can be made here Parameter Description Type E mail Name Recipient s name e g My name E mail address Recipient s e mail address in the Internet e g M
44. s are compiled and reported together with the remaining registered events Daily Once daily at 00 00 hours a check is made as to whether events in the event group occurred the previous day New events are compiled and reported together with the remaining registered events Weekly At 00 00 hours on every Monday a check is made as to whether events in the event group occurred in the ast seven days New events are compiled and reported together with the remaining reg istered events Activate Deactivate Alarm Activate De activate Clicking on the relevant icon will activate or de activate the alarm Checking or un checking the check box in the settings will be automatically undertaken by the system Current status is shown by the following colours Black Active alarm Grey Inactive alarm I All functions for editing event groups remain enabled even after alarm deactivation E mail Messages Events are reported via e mail in accordance with the message and recipient settings E mail language is the same as that set for the message recipient The structure is equal for all sent messages only the content is individually arranged From Sender address e mail service To Message recipient Subject Event group system name time stamp start end of last events Event group system name time stamp start end of last events List of event messages C00410334 01 Danfoss 8 Working
45. se ComLynx Weblogger Important information in the manual is identified by means of various symbols shown below Attention The attention symbol indicates an item whose disregard may result in damage to equipment and or harm to persons Information thus marked must be observed on all accounts Information The Information symbol indicates supplementary information the observance of which by the user leads to improved performance Additional information for the user This document incorporates the latest version at the time of printing It is subject to changes required by new functions and improvements The names of products and companies mentioned in this document may be protected trademarks C00410334 01 3 2 Safety Instructions Danfoss 2 Safety Instructions Readers of this manual are assumed to be familiar with regulations and guidelines concerning electrical installations and their connection to the mains power network Particular attention must be paid to general safety regulations for working with electrical installations Please observe the safety instructions below to prevent injury to persons and damage to connec ted equipment Contact with electrically conductive parts can be life threatening even after their disconnection from the mains network Installation should only be performed in the de energised state Do not use metallic pointed sharp instruments to access the hou
46. sing s interior E Prevent cables and terminals from being exposed The power connection must be equipped with a fuse and earthing The power plug must be accessible at all times Qualified personnel only must perform maintenance Equipment must only be operated at the rated supply voltages 12 24 VDC correct polarity A suitable power supply unit is included in the scope of delivery Equipment must be installed only in protected dry environments Note Z Observe the manufacturer s instructions regarding the handling of power supply units espe cially switching units Observe the manufacturer s instructions regarding the handling of inverters Mechanical modifications to equipment including installation of bores will result in damage and invalidate all guarantee claims 4 C00410334 01 268 3 ComLynx Weblogger Description 3 ComLynx Weblogger Description 3 1 System Overview A system for acquiring processing evaluating and distributing system related information ComLynx Weblogger is a concept based on many years of experience It is designed especially for monitoring processes at regenerative power plants The system incorporates the following func tions Detailed query and storage as well as continuous evaluation of inverter data Monitoring of yield events and power Issue of e mail alarms on occurrence of incidents issue of error messages configurable Preparation of reports
47. ssary See Chapter 8 2 1 Configuration System language Edit Set system language English Save Cancel Illustration 8 30 Editing System language A new language can be chosen via the drop down menu and saved The new language will func tion after a time out or new session see Chapter 8 3 42 C00410334 01 268 8 Working with ComLynx Weblogger 8 6 Plant Status The plant status is a dynamic dialog in which current inverter data are scanned and listed in a tabular overview The plant s current status is indicated here this includes current power and event of each individual inverter This table provides brief details on active in Plant state Inverter I I verters settings including serial number day System time 2006 11 30 13 36 19 yield output power and time of last data re quest Inactive inverters are not displayed in the Inverter1 plant status window Related settings are de Inverter2 scribed in 8 5 11 Inverter3 The Refresh function can be used to re scan offline Inverter4 inverter status and update system time Power W Day yield kWh Refresh Illustration 8 31 Plant Status An inverter s status details can be viewed by clicking on the corresponding Inverter name e g Inverter1 C00410334 01 43 2 2 8 Working with ComLynx Weblogger Plant state Inverter System time 2008 05 27 12 55 27 Name 440 Timestamp 2002 03 27 12 55 16 Serial number O44000P0608
48. t data Very long cables to the temperature sensor distort measurement values A 10 metre long copper cable with a cross section of 0 25 mm generates a measurement error of approximately 0 5 C on a PT 1000 temperature sensor If no voltage source is connected e g for irradiance the factory wiring needs to be modified see Chapter 8 5 11 Drift voltages at the open measurement input would be interpreted and recorded as operational sensor values by the data logger C00410334 01 11 5 First Installation Danfoss 5 First Installation This section can be skipped if the ComLynx Weblogger s to be operated only via its modem Analogue ISDN except GSM interface remote data transmission If the ComLynx Weblogger is to be integrated into a local area network LAN it first needs to be checked with a network administrator if the delivery status IP address is already occupied in the same network Should this be the case a new IP address has to be requested from the network administrator and then has to be adapted via direct connection in the device and PC The delivery status IP address of the device is set to LAN IP address 192 168 1 190 network mask 255 255 255 0 see Chapter 3 4 point 6 With this IP address entered into a web browser the ComLynx Weblogger homepage opens File Edit View Favorites Tools Help Back QJ x a N y Search ie Favorites Address http 192 168 190
49. ter Network Connection to the inverters is established in accordance with the inverter data bus types ee ee Connection to an inverter via a standard com mercial RJ45 network cable RJ45 terminator is included in the scope of delivery Illustration 6 3 Network Cable RJ 45 Terminator C00410334 01 15 6 Connection and Start up Danfi Attention RJ45 double sockets for inverter communication should not be mistaken for RJ45 LAN sockets identified by 2 LEDs 6 3 Electrical Mains Connection Power supply via a plug in power supply unit Illustration 6 4 Plug in Power Supply Unit The power supply is to be connected by means of the plug in power supply unit 12 V included in the scope of delivery ComLynx Weblogger typically has a power consumption of 5 7 W Attention Connection to the mains supply must only be established after installation of the hardware and all other cables 6 4 Switch on ComLynx Weblogger is ready for operation approximately 60 seconds after connection to the mains power supply To ensure that all LEDs are functioning correctly all LEDs will light briefly The unit is now ready 6 5 ComLynx Weblogger Connections Before connecting a network cable an initial installation is necessary Here the IP address needs to be checked and eventually adjusted in the device which is a prerequisite for the communica tions between ComLynx Weblogger and PC For remote a
50. th ComLynx Weblogger An unsuccessful data transfer will be logged as an event in ComLynx Weblogger Monitoring The following settings are possible Parameter Description Serial number Serial number of the ComLynx Weblogger The Serial number together with the portal code are needed for the data transfer Portal code Password needed for the data upload to the Webportal The portal code is received when registering at www meteocontrol de The serial number of the ComLynx Weblogger is needed when creating the portal account Data transfer A data transfer interval can be specified Status By checking unchecking the data transfer is activated deactivated Permissible intervals for the data transfer are Hourly Every hour a data transfer of the logged data is issued Daily Once a day at 00 00 a data transfer of the logged data is issued A prerequisite for the data transfer is a valid and active Webportal account at www meteocon trol de Information and details can be requested from Danfoss 8 5 10 PV Plant Under PV plant you can individual edit and view details on the entire plant including the moni toring options set for the alarm system Configuration PV Plant Nominal power of plant 20 kwp Supervisory options Inverter failure enabled Income deviation 10 of mean value Minimum income for 1 kWh per day income comparison Alarming time 30 minutes Edit Illustration 8 21 Overvie
51. the check box in the settings will be automatically undertaken by the system Current status is shown by the following colours Black Active alarm Grey Inactive alarm q All functions for editing event groups remain enabled even after alarm deactivation 52 C00410334 01 268 8 Working with ComLynx Weblogger 8 8 2 E mail Messages E mail is sent to the user as part of every evaluation E mail language is the same as that set for the message recipient The structure is equal for all sent messages only the content is individually arranged From Sender address e mail service To Message recipient Reference Evaluation system name time stamp day month year Report system name time stamp day month year Diagram Line diagram or bar chart depending on the evaluation type Timestamp logged event if available Day power System name 2006 10 19 H H n2 10000 1200 1000 800 600 4 00 7 00 10 00 6 00 19 00 22 00 13 00 1 19 October 2006 Day yield 4 38 kwh No malfunctions events Illustration 8 42 Example of Report Notification E mails whose delivery failed as a result of incorrect addressing for instance are logged in the system messages Incorrect addresses should be rectified as soon as possible Should several people require simultaneous information it is recommended to use a distribution list e g support testaddress com 8 9
52. the previous graphics setting is retained Graphics prerequisites Less than 300 KB Format jpg Recommended size 500 x 300 pixel format jpg Click on Add text and then fill the Description max 200 characters and 7ext max 30 char acters fields to create a new row of details You can click on Add text repeatedly to add any required number of new rows to the current one Clicking on Save displays the created rows of information on the main page Text can be formatted by means of HTML tags Deleting the contents of a row and clicking on Save deletes the row 8 5 9 Webportal 36 Under Webporta the dial up parameters for the data transfer from the ComLynx Weblogger to the Webportal can be configured Configuration Webportal Serial number CK9181P0907 Portal code EETRTEF Data transfer daily transmission at midnight Status activated gt Edit Illustration 8 19 Overview Webportal The Webportal settings can be changed with dit Admin access is necessary See Chapter 8 2 1 Configuration Webportal Edit Serial number CK9181P0907 Login for Webportal transfer Portal code Data transfer daily transmission at midnight Status active Save Cancel You receive the portal code by registering at meteocontrol de Please have the serialnumber of the weblogger ready Illustration 8 20 Edit Webportal Settings C00410334 01 268 8 Working wi
53. ther modifications i For the use of some functions Java Script needs to be enabled For details please D consult your browser s manual 8 4 Language Options The Web interface of the ComLynx Weblogger offers a choice of languages which can be indi vidually configured for each session C00410334 01 25 8 Working with ComLynx Weblogger Danfoss The language of choice for the user interface is chosen by clicking on the relevant national flag and will revert to standard language setting at the end if each session or a period of inaction on the user interface of approximately 10 min Details of the configuration of the Standard Language Options can be found in Language Options Chapter 8 5 13 8 5 Configuration Clicking on Configuration provides an overview of the ComLynx Weblogger current system pa rameters and other information such as free and used harddisk space Compact Flash card as well as main memory From here you can perform settings in further sub menus for network Internet access e mail etc Configuration System information System name ComLynx Weblogger Host name ComLynx Linux kernel 2 4 28 System is running since 0 day s System time 2007 06 25 16 01 26 Hard disk capacity 237MB total 130MB free 39 used Main memory 61MB total 39 used Serial number 0050C229F123 Software version 1 0 14 Hardware version 1 2 Illustration 8 4 Overview of System In
54. tings assigned automatically if your network supports this capability Otherwise you need to ask your network administrator for the appropriate IP settings Obtain an IP address automatically Use the following IP address IP address 192 168 1 192 Subnet mask 255 255 255 0 Default gateway Use the following DNS server addresses Preferred DNS server Alternate DNS server Illustration 5 3 TCP IP Connection Properties Confirm your settings with Ok C00410334 01 13 5 First Installation Danfoss Under network configuration see Chapter 8 5 1 enter the new IP address User and access rights see Chapter 8 2 must be observed here i Details of the configuration of the network settings must be observed and if neces amp sary checked by an administrator see Chapter 8 5 1 14 C00410334 01 Panett 6 Connection and Start up 6 Connection and Start up 6 1 Connection via LAN Interface or Modem ComLynx Weblogger is operated exclusively from a web browser Internet Explorer from Version 6 or Firefox with access via a LAN interface or modem dial up i a ttl eatin nora LAN Ethernet connection via patch cable or direct connection via cross link cable scope of delivery Illustration 6 1 Cross link Cable Modem connection RS232 SUB D9 COM1 Modem Dial in IP 192 168 2 1 Illustration 6 2 Modem Connection 6 2 Connection to the Inver
55. vents and system incidents Example System was restarted on 2006 07 27 15 16 03 System Details Important or special events e g problems with mail dispatch Example A mail could not be sent Couldn t connect to mail gmx net Inverter Events Events reported from the inverters such as monitoring status overvoltage overtemperature and grid failure Example Inverter1111111 DC module 1 reports error U PV C00410334 01 45 8 Working with ComLynx Weblogger Danfoss 8 7 1 46 No Daily Yield No daily yield check takes place daily at 6 pm Settings and descriptions are provided in 8 4 9 PV plant Example No daily yield from inverter1111111 Low Daily Yield Low daily yield comparison takes place daily at 6 pm Settings and descriptions are provided in 8 4 9 PV plant Example Yield deviation for inverter1111111 100 Inverter Failure If an inverter wasn t reachable for a whole day the check is made daily at 6 pm Settings and descriptions are provided in 8 4 9 PV plant Example Failure of inverter1111111 for the whole day To open the event group click on the header row of the group All events recorded up to this point will automatically be displayed by the system All occurred events are indicated here in chronological order The most recent events are shown first Events are recorded as follows Time Date and time of the event Event Event report Timestamp Event 2006 07 28 15 12 55 Network
56. verter you can view and individually configure all inverters detected by the system You can also search for new inverters here Configuration Inverter Inverter network Inverter Search Inverter Wechselrichter1 Wechselrichter2 Wechselrichter3 Wechselrichter4 Illustration 8 23 Overview of Inverters The inverter Search function permits easy scanning for all operational enabled inverters also known as scanning and is necessary for working with the ComLynx Weblogger Configuration Inverter Inverter network Inverter Illustration 8 24 Inverters Search A search can be renewed at any time all newly found inverters are included in the search log Clicking on the serial number of an inverter opens the related settings window Configuration Inverter Edit Inverter serial number 222000H0705 A Inverter description Wechselrichter 2 e g Inv1 Inverter group Inverter status active Monitoring active max power input 1608 Wp Illustration 8 25 Editing Inverter Settings C00410334 01 39 8 Working with ComLynx Weblogger Danfoss Delete removes the inverter from the system Note the information provided under automatic network search The following settings can be made here Parameter Description Inverter serial number Assigned by the manufacturer this serial number cannot be changed Inverter description Unique description for the inverter compulsor
57. w do you want to connect to the Internet This type of connection uses 4 modem and a regular or ISDN phone line Connect using a broadband connection that requires a user name and password This is a high speed connection using either a DSL or cable modem Your ISP may refer to this type of connection as PPPoE Connect using a broadband connection that is always on This is a high speed connection using either a cable modem DSL or LAN connection It is always active and doesn t require you to sign in gt Illustration 6 8 Connection Using a Dial up Modem 18 C00410334 01 222 6 Connection and Start up Select a modem Hew Connection Wizard Select a Device This is the device that will be used to make the connection You have more than one dial up device on your computer Select the devices to use in this connection Modem Standard 33600 bps Modem COM2 mf Modern Standard 56000 bps Modem COM1 Illustration 6 9 Modem Selection If only one modem has been installed no list of modem choices will appear Enter a name Hew Connection Wizard Connection Name What is the name of the service that provides your Internet connection Type the name of your ISP in the following box ISP Name The name you type here will be the name of the connection you are creating Illustration 6 10 Entry of a Name Internet Server C00410334 01 19 6 Connection and Start up a E
58. w of PV Plants Settings can be changed with Ea t Admin access is necessary See Chapter 8 3 1 C00410334 01 37 8 Working with ComLynx Weblogger Danfoss 38 Configuration PV plant Edit Nominal power of plant eu kwp Supervisory options Inverter failure activated failure gt 24h Comparison yi patrons 10 of mean value usual 10 Minimum income for 1 kWh per day usual 10 of max day income comparison income Reaction holding tina 30 minutes v Illustration 8 22 Editing PV Plant Parameters The Supervisory options options are used to configure the inverter alarm parameters Inverter failure If Inverter failure is activated an alarm is issued on a failure of any inverter An inverter is assumed to have failed if it does not communicate with ComLynx Weblogger for an entire day Income deviation An alarm is issued if an inverter supplied insufficient energy compared with the remaining inverters on the previous day This is attributable to soiling partial failure of solar cells or a faulty inverter circuit The Income deviation field is used to specify a percentage of the mean value serving as a basis for evaluating yield The settings below must be performed for yield deviation Income deviation Percentage deviation of an inverter s income from the expected share Minimum income for comparison A minimum income can be specified to avoid in correct alarming on days with
59. with ComLynx Weblogger Subject Configuration events system name 2006 10 15 14 00 11 2006 10 19 16 55 25 Configuration events System name 2006 10 15 14 00 11 2006 10 19 16 55 25 2006 10 16 2006 10 16 2006 10 16 2006 10 16 2006 10 16 2006 10 16 14 15 17 11 16 16 00 15 rag 55 So O5 11 So bar 2i 10 ag Automatic network scan was performed PY plant configuration modified System time configuration modified Manual network search was performed Message recipient Alarm added Message recipient My email notification added Illustration 8 37 Example of Configuration Notification E mails that cannot be delivered as a result of incorrect addressing for instance are logged in the system messages Incorrect addresses should be rectified as soon as possible Should several people require simultaneous information it is recommended to use a distribution list e g support address com 8 7 3 Notification of Alarm If a device has been connected to the alarm contact of the ComLynx Weblogger the message recipient 8 5 7 alarm contact needs to be set up activated and selected as message receiver If an alarm is triggered an alarm confirmation appears on the main page of the ComLynx Weblogger which can either be acknowledged by pressing the alarm off button or will automat ically be deactivated by the system after the alarm duration 8 5 7 has passed
60. y entry Special char acters or blank spaces are not permissible here Note The descriptions are used for the inverter reference in the re ports Inverter group Here you can individually define an inverter group One or more groups can be specified e g group 1 group 2 etc Inverters are displayed in accordance with their group affiliation Inverter status The inverter monitoring can be set to active inactive via activating deactivating the checkbox Monitoring The alarm function for monitoring excessively low daily income can be activated deactivated here also refer to Chapter 8 5 10 Max input power The maximum power calculated so far is indicated here which can be entered manually or overwritten automatically from the system if a higher value is registered Mandatory field Inverter settings must be performed individually for each connected inverter Automatic network scan At 10 00 am and 2 00 pm every day the system commences a network scan This permits ComLynx Weblogger to search for connected inverters Inverters not yet registered are added automatically to the configuration event log see also Chapter 8 6 I Deleted inverters with an active status are added again automatically during the network search procedure Deactivating the Inverter status check box can prevent this 8 5 12 Sensors Additional sensors can be connected and scanned via the ComLynx Sensor Interface

Download Pdf Manuals

image

Related Search

Related Contents

OPERATING INSTRUCTIONS INSTRUCCIONES DE OPERACION    Samsung 18.5英寸 高光泽黑色 LED 液晶显示器 用户手册  Magnasonic MDVP455 Projector Accessories User Manual  Trousse de dépistage d`un trouble mental chez la clientèle  Finisar FTLX0071D4BNL network transceiver module  L`EXTERMINATEUR PM - 57 POUDRE INSECTICIDE  the Kosmos mininova User Manual.  Chief RSA027 project mount  Liquid chromatography quadrupole time-of  