Home
FL 1000
Contents
1. mains 5 Surface mounting 1 Attach to surface using two screws not supplied in the baseplate holes 6 Installing in closed compartments Requirements Enough space to allow natural heat transmission through surfaces Surfaces should not be insulated Air volume per light generator minimum 0 03 m Ventilation holes per light generator with min 20 cm air inlet and min 20 cm air outlet Inlet and outlet ventilation holes opposite each other Max ambient temperature 45 C Measuring temperature see Troubleshooting Min 100 mm 7 Installing adjacent light generators Requirement min 100 mm distance between adjacent light generators in order to ensure sufficient heat transmission m lt lt a S i l T 8 Mounting filters Colour filters not supplied CTC filters not supplied 1 Unscrew the plastic front part from the light generator 2 Assemble the filter and bracket 3 Mount the assembled filter in the detached front part 4 Screw the front part on to the light generator ied i 9 Mounting diffusion adaptors Not supplied 1 Remove the screw 2 Mount the diffusion adaptor 3 Insert and tighten the screw ot A 10 10 Spare parts Model designation LED FL 1000 module excl cooling EN LED FL 1000 module excl cooling US LED FL 1000 module incl cooling EN LED FL 1000 module incl cooling US Cooler SynJet Philips 25W CC 220 240 V P
2. FL 1000 LED light generators for use with fibre optic lighting User manual Mounting and installation instructions Item no 99082079 39 09 2013 0122 0050 0122 1050 0122 0053 0122 1053 0122 2050 0122 3050 0122 3053 0122 0040 0122 1040 0122 2040 0122 3040 FL 1000 B 1 3000 K FL 1000 B 2 3000 K FL 1000 B 1 3000 K CRI 90 FL 1000 B 2 3000 K CRI 90 FL 1000 B 1 US 3000 K FL 1000 B 2 US 3000 K FL 1000 B 2 US 3000 K CRI 90 FL 1000 B 1 4000 K FL 1000 B 2 4000 K FL 1000 B 1 US 4000 K FL 1000 B 2 US 4000 K RRoblon Contents 1 Introduction 2 Product overview 3 Technical data 4 Installation 5 Surface mounting 6 Installing in closed compartments 7 Installing adjacent light generators 8 Mounting filters 9 Mounting diffusion adaptors 10 Spare parts 11 Accessories 12 Troubleshooting 1 Introduction Roblon FL 1000 light generators are designed for use indoors with glass or PMMA fibre in all installation set ups including in closed compartments Follow the installation instructions correctly in order to ensure Safe operation enhanced functionality extended lifetime for components uninterrupted illumination 2 Product overview FL 1000 light generator Q28 gt 9 harness adaptor Allen key Power cord User manual FL 1000 B 1 FL 1000 B 2 FL 1000 B 1 US FL 1000 B 2 US 3 Technical data Light port Fibre type Total power consumption 350 mA Total power consumption 700 mA Supply
3. hilips 35W CC 120 277 V Description LED module no cooling B 1 LED module no cooling B 1 US LED module with cooling B 2 LED module with cooling B 2 US SynJet Z Flow 65 Driver US 11 Accessories CTC Filter A 500K CTC filter 0126 1000 CTC Filter A 900K CTC filter 0126 1002 CTC Filter A 1200K CTC filter 0126 1001 Colour Filter FL 1000 yellow Yellow colour filter 0126 1004 Colour Filter FL 1000 green Green colour filter 0126 1005 Colour Filter FL 1000 blue Blue colour filter 0126 1006 Colour Filter FL 1000 red Red colour filter 0126 1007 Diffusion Adaptor Diffusion Adaptor 0126 1003 11 12 Troubleshooting Trace the problem Solution S No light Is the power on Turn the power on Is the power cord connected Connect the power cord properly properly Is the light generator too hot Check it is installed according to the instructions Switch generator off Let it cool for 15 minutes Try again fis the LED working Replace the LED Cooling system is running Is the light generator too hot Check it is installed according to but no light B 2 and B 2 the instructions Switch US generator off Let it cool for 15 minutes Try again Light switches on and off Is the light generator too hot Check it is installed according to the instructions Switch generator off Let it cool for 15 minutes Try again B 2 and B 2 US Light output has Has the light been dimmed via a Inc
4. rease brightness using dimmer diminished dimmer switch switch Is the light generator too hot Check it is installed according to the instructions Switch generator off Let it cool for 15 minutes Try again REE onrithtinctewcoth Dry with lint free cloth a T Dry with lint free cloth Ambient temperature max 45 C Measured 50 mm from light generator Surface temperature max 73 C Measured 15 mm from edge on top of light generator when it has been running for min 1 hour Measure surface temperature here e Measure ambient temperature here Roblon Roblon Lighting Tel 45 9620 3300 Nordhavnsvej 1 Fax 45 9620 3399 9900 Frederikshavn info roblon com Denmark www roblon com Roblon accepts no responsibility for possible errors in printed and electronic material Roblon reserves the right to alter or discontinue products without notice 2012 Roblon A S
5. voltage Applied LED Light source lifetime CCT nominal CRIg Ra typical value Protection rating Driver type Driver lifetime Dimmable Thermal protection Cooling system Noise level Ambient temperature Material Dimensions L x H x W Driver size Lx H x W Weight Safety 9 or 28 mm PMMA Glass 13 W B 1 25 W B 2 120 277 V 50 60 Hz Lumileds LUXEON S 50 000 hours 3 000 K 85 IP20 External electronic 50 000 hours Trailing edge 1 10V US models Automatic decrease Natural convection B 1 Synjet B 2 N a B 1 18 dB A B 2 20 C to 45 C AlMgSiPb 6262R POM 155 x 86 x 70 mm B 1 190 x 86 x 70 mm B 2 188 x 46 x 32 108 x 77 x 30 US models 0 5 kg B 1 0 7 kg B 2 CE RoHS WEEE UL pending CB pending 4 Installation 1 For use with 9 harness Mount the 28 gt 9 harness adaptor on the common end Tighten the screw with the Allen key 2 Insert the common end fully in the light port 3 Tighten the screw on the light port 4 1 10V dimming US model See Dimmer selection guide for FL 1000 models on www roblonlighting com Choose a compliant dimmer Connect dimmer cable red wire to the corresponding terminal in accordance with dimmer instructions Connect dimmer cable black wire to the corresponding terminal in accordance with dimmer instructions 5 Ensure all installation and ventilation requirements are met 6 Connect the supply cord to the