INSTALLATION AND USER`S MANUAL
Contents
1. Installation manual EKO LIGHTSYSTEMS The ADR is a motion sensor system for turning on lights Movement is detected using a pyroelectric infrared sensor PIR The PIR reacts to changes in temperature patterns People and animals radiate heat If they enter or move within the range of the ADR motion sensor the heat patterns change within this range The ADR detects this and interprets it as motion It remains activated until the source of the heat leaves the area or stops moving INSTALLATION AND USER S MANUAL Veko 2010 Schagen Version 0 LIGHTSYSTEMS INTRODUCTION The ADR is designed so that it does not immediately switch off when it no longer senses any motion it uses a so called delay switch The motion sensor has a timer which resets each time it detects movement When the timer runs out the lights are switched off The ADR is equipped with a twilight switch which enables the system not to switch on the lights if the amount of daylight exceeds a certain level This level can be set using a potentiome ter Installation manual 130 140 EKO LIGHTSYSTEMS ADRs are suitable for mounting in ceilings and are available in both a recessed version ADRI and a surface mounted version ADRO Both have a detection angle of 130 to 140 This equates to a diameter of 6 to 7 metres from a ceiling height of 2 5 metres The optimal ceiling height is 2 5 to 3
2. metres The higher the ceiling the less sensitive the motion sensors will be Caution The sensitivity of the motion sensor deteriorates towards the outer edge of its range EKO LIGHTSYSTEMS PLACEMENT The ADR functions optimally in the centre of the room taking into account the following factors that may have a negative effect on its operation e Avoid direct air currents e g from a heater or air conditioning unit e Avoid direct radiation from infrared sources such as incandescent lamps and halogen bulbs and reflected sunlight off water or reflective surfaces for instance e Ideally the horizontal distance from the device to the entrance to the room should be at least 2 5 metres CEILING MOUNTING Remove the sensor unit from its casing Check that the connector is properly mounted it will click when pushed Cut a circle with a diameter of 73 mm in the ceiling Push the springs up with both hands and guide the casing through the hole in the ceiling Release the springs If the ceiling is soft put reinforcement under the spring Put the detector into the ceiling ring Turn to the right until the bayonet fitting locks Potentiometers can be set before installation and can also be adjusted later to the desired setting Installation manual CONNECTION Before you connect the ADR turn the mains off Standard connection Connect phase L to the brown wire the switch wire S to the bl
3. Ensure that the wires are connected according to the colour coding Comply fully with the technical specifications of the equipment Do not use cold start switches if the ADR is likely to switch on the lighting more than twice in a 24 hour period The ADR is not certified for use as an alarm system Installation manual Fault Lighting is not switching on Lighting is switching on unnecessarily Lighting is switching off unnecessarily Lighting on permanently Lighting is not switching off when there is sufficient daylight TROUBLESHOOTING Possible cause No current Twilight value not yet reached Bulb defective Switches on after loss of current Sudden change in heat patterns e g printer fan air conditioning etc within detection range No detection within set delay time Person is outside detection range The detector is higher than 3 metres No current Switch is overridden by installation switch Heat patterns within detection range are constantly changing Never switches off with sufficient daylight Solution a check mains a adjust settings t replace t wait a choose a better site a lower sensitivity a choose longer delay a choose a better site a use more detectors a set the delay to longer a use more detectors i choose longer delay a mount the detector lower a reset mains t turn switch off t choose a better site E leave the room and wait until the delay
4. ack wire and neutral N to the blue wire The order of connections in Figures B and C is the same as in Figure A If the current to the ADR is switched on the lighting will always be switched on alalelal O F F Do not apply version B if inductive T yo lighting is used such as conventional pre switching equipment Do not use cold start switches if the ADR is likely to turn the lights on more than twice a day Connecting several ADRs in parallel for large rooms Installation manual SETTINGS 1 Delayed off switch The ADR has a rheostat delay switch that can be adjusted using a potentiometer Only use the shortest delay setting potentiome ter fully to the left to test the ADR and the installation Caution Do not set the delay switch to less than 5 minutes for vapour lamps Short switch times have a negative effect on the lifespan of these lamps because they are not given enough time to warm up Motion detection SAFETY Before you connect the ADR the current must be turned off Only certified electricians are permitted to work on 230V current All installation instructions must be followed If in doubt consult VEKO lightsystems technical service department
5. switch time passes SETTINGS 2 Twilight switch The ADR comes with a twilight switch This ensures that the lighting is not turned on if there is sufficient daylight in the room If this is the case and the daylight level drops below the set value while the room is still occupied the lighting will turn on If the lighting is on and the amount of daylight rises above the set value the lighting will stay on This prevents unnecessary switching on and off Turn clockwise for higher twilight value and counter clockwise for a lower twilight value A higher twilight value means that more daylight is required to stop the lights from turning on Adjust the potentiometer to max to turn the twilight switch off altogether sy AZS Onset of twilight aes TECHNICAL SPECIFICATIONS Nominal voltage 230 V 10 50 Hz Maximum continuous 6 A at cos p 1 power 2 A at cos 0 4 Usage switched on off lt 0 5W lt 4W PIR detection angle All round 130 140 Switched off time delay 5 sec 30 min motion Ambient temperature 0 40 C Appliance class IP20 veko CE Rev 0 December 2010
Download Pdf Manuals
Related Search
Related Contents
Partner Tech P53-675DWA User's Manual Honeywell XYR 5000 Wireless Acoustic Signal Transmitter User PDFファイル - 医薬品医療機器総合機構 Logitech K200, SE FT 0127122 Action Verte Lessive poudre concentrée 10kg User Manual for Virtual Bank's Transaction Portal Table Topfield TF 5100 CI Satellite TV System User Manual PSC estradosso Copyright © All rights reserved.