Home
        Product Manual - Formula Sound
         Contents
1.      E  Timer adjustment pre set  M  Terminals to connect level 2 selector switch     F  Level 1  normal  adjustment pre set  N  Terminals to connect remote reset switch     G  Level 2 adjustment pre set   see M  to select  P  Terminals to connect low voltage contactor     Q  Fire alarm connection     R  Terminals to connect mains coil contactor    S  Connection for a mains warning lamp  60 Watts max   T  Mains Input Terminals    U  Bottom mounting holes    V  Voltage selector   Slide switch     W  Isolated relay contacts           www formula sound co uk    TITLE   SENTRY MK2   version 3          DETAILS OF TERMINALS AND OPTIONS    DRG No  879                LOCATED BENEATH REMOVABLE COVER  DATE 30 11 2011   ISSUE R6             FUSE  10 x 38mm HRC Type gl 32 Amp                   O                                                          O   amp    amp    amp                                                                 OBX  coil  2O       O  amp   B   amp    amp                             Control voltage  from    SENTRY LITE    DRG 425PCB  Ref  J                                      d OON 0     LOW VOLTAGE INTERFACE CIRCUIT BOARD                        bel                                                                          O    ORENS                      DISCONNECT POWER BEFORE REMOVING COVER  THIS UNIT SHOULD ONLY BE INSTALLED    amp  MAINTAINED BY A SUITABLY QUALIFIED PERSON  THIS EQUIPMENT MUST BE EARTHED     TO ENSURE SAFE OPERATION OF THIS UNIT AND THE EQUIPME
2.  are where visitors will place them   the maximum allowable level is  determined by the environmental health officer but will typically be either a level just audible in a  neighbours premises or a set level at the boundary of the premises     With the music at the maximum allowable level adjust the Sentry  Adj 1  to be between    warning    and     Over limit    on the display     Note  Reducing the amount of sound escaping from a venue will generally increase the sound level  the venue is allowed to operate at  doors  windows  direction and mounting of speakers all affect  sound levels from a venue     FORMULA SOUND LTD    UNIT 23  STADIUM BUSINESS CENTRE  NORTH END ROAD   WEMBLEY   MIDDLESEX   HA9 OAT    TEL  44  0  208 900 0947   FAX  44  0  208 903 8657  Email info formula sound com  www formula sound com    DISCONNECT POWER BEFORE REMOVING COVER                                      OLTSGE SELECT                                                                                              OPTIONAL  ONTACTO          CAUTION MAINS VOLTAGE CONNECTIONS                                         A  Internal  External  Measuring microphone selection  H  Reset switch connector    B  External measuring microphone connection terminals  J  Terminals for the connection of external Led indicators etc     C  Phantom power selector for external microphone  K  Security loop connection  Link if not used     D  Weighting response selector   measuring microphone  L  Output for a Slave Display
3.  ensure that  the earth is also connected  The mains consumption is approximately 1 amp at 240V  a5 amp  lighting feed could be utilised  Connect via an isolating switch or removable plug socket arrangement  so that the unit can be isolated when necessary     For use on 120V the consumption will be approximately 2amps    ENSURE THAT THE MAINS SUPPLY IS NOT THE SAME AS THAT CONTROLLED BY THE  CONTACTOR     Warning Lamp    Provision to switch a mains warning lamp to a maximum of 60VA is provided  The lamp can be of  any style considered suitable but must have a maximum consumption of 60VA  60 watts   It is  connected to the mains outlet terminals labelled  warning lamp   Alternatively a relay or contactor  may be used to switch other lamps as required  Good wiring practice should be observed     Remote Reset  Detail on page 12    Setting the Permissible Volume Level    Adjustment of allowable noise level is made by adjusting the pre sets ADJ 1 and ADJ 2  These are  located beneath the removable cover at the left hand end of the unit  They are 10 turn pre sets to  provide fine adjustment  ADJ1 sets the normal operating level  ADJ 2 sets the level for a second  threshold  Level 2  which can be initiated remotely  An indicator on the front panel will show when  level 2 is selected  Take care when making adjustments and use a small screw driver  Try to make    9    adjustments when the noise level is displayed on the bar graph meter as you will be able to see the  changes displayed
4.  for day and night or  weekdays weekends then a switch  or timer  may be used to change to a second setting     Sentry MK 2  ENVIRONMENTAL NOISE CONTROL SYSTEM    Features    e A choice of internal microphone  supplied factory fitted as standard  or external microphone  with  or without phantom power  may be selected  External microphone not included     e A choice of weighting filters  A  C  BASS  or no weighting filter  LIN     e Two sound level thresholds may be set  level 1  default  and level 2  Switching from level 1 to  level 2 can be done on a switch or a timer    e Security loop  eg for fire alarm or fire doors    e Anti tamper microphone circuitry is incorporated with a front panel indicator    e Dual mains voltage operation is standard  internally switchable    e Case provides easy connections via cable entry knock outs and screw terminals   e Fire alarm interface   e Pair of isolated relay contacts   e Large display plus ability to power mains 60W warning light   e Will drive low voltage or mains contactor   e Slave display option   e Remote reset option  push button or keyswitch    e Factory set to about 20 seconds just over limit before tripping   e AT1 option allowing sound levels to be controlled    General Detail   Any function that can be controlled by a relay or switch can be controlled by the Sentry  These may  include disconnecting loudspeakers  switching passive attenuators to reduce system volume or acting  as the trigger into an active attenuator syste
5.  if the Mic tamper or Security loop indicators are illuminated     Security loop    The security loop feature is provided on two terminals behind the removable cover plate  while the  two terminals are linked the Sentry will operate but if the link is broken  for more than half a second   the Sentry will trip     This feature can be used as in any circumstance that the Sentry is required to be tripped  eg fire  doors can be fitted with a magnetic relay so that if the fire doors open the relay breaks the circuit and  the Sentry is tripped     A front panel LED indicator will show SECURITY LOOP if the link between the two terminals is    broken and the Sentry will trip the contactor  the Sentry will not reset until the link is restored  LED  indicator off      Time levels exceed limit before the Sentry trips  The period of time that noise  over limit  is tolerated before the unit trips out is variable over the range    of 10   70 seconds  A pre set is provided to adjust this should it be necessary   the factory setting is  approx  20 seconds     Fire alarm interface   The fire alarm interface option allows the Sentry to be interfaced to a fire alarm  the interface can be  set to accepted a trigger of voltage applied  up to 24V   voltage removed  contacts closing or contacts  opening  Factory setting is    voltage applied        Isolated contacts    A pair of relay contacts that are normally open and close when the unit trips allow other equipment to  be switched if required  co
6.  on the meter     The adjustment pre sets have a slipping clutch at the end of travel to prevent damage  But this can  cause confusion if the pre set is at the end of travel as it then appears to do nothing  this is not  usually a problem once you know about it      The actual sound pressure level  SPL  at which the unit operates can only be determined by  measuring the noise level using a calibrated sound pressure level meter and adjusting the unit  accordingly  Play music at the maximum required level  monitor with SPL meter  and adjust ADJ1 so  the    LIMIT    LED   s  right hand of display  are going on and off  A small increase in the music level will  now trip the system after about 20 seconds  level 1 is now set  Repeat for level 2 if the second level  is also to be used     Alternatively the unit may be adjusted using trial and error but this should be used only as a  temporary measure or last resort  Measuring the sound level and setting to a limit agreed with the  local area official is the only recommended method     An internal measuring microphone is fitted which will be suitable for most applications but should the  need arise an external microphone can be connected  The external microphone may be a moving  coil type  capacitor or electret  Microphone phantom power is provided and may be selected as  required  Select a microphone with the required frequency response and polar response   Please  telephone our technical department if help is required      NOTES   
7. 0082 1 BS EN 50081 1  PRODUCT TYPE    SENTRY MK2  The CE mark was first applied in 1995    Signed    B  J  Penaligon General Manager    Attention    The attention of the specifier  purchaser  installer  or user is drawn to the fact that good wiring practice must be  observed when connecting the above equipment  Good quality connectors and screened cables must be used  for all audio connections  Twin screened cables should be used for all balanced lines     THIS EQUIPMENT MUST BE EARTHED  CONSULT THE USERS MANUAL FOR TECHNICAL DETAILS       
8. ALLATION  1  Remove lid of unit by removing the screws  amp  pull off the lid earthing connector    2 Decide on fixing position  amp  the required 20mm conduit entries  The entries  are plugged with plastic bushes which can be removed with a screwdriver   There are two small diameter plugged holes on the left hand side which may be useful  for the low voltage control cable   Grommets are included to bush any holes that are used     3  The box should be fixed to a suitable surface using the four base mounting holes   A template is included to assist in fixing     4  Make electrical connections to the unit refering to the drawing  A suitable means  of isolating the unit should be provided to allow any maintenance to be undertaken  safely     5  ENSURE THAT THERE IS ADEQUATE SEPARATION BETWEEN LOW VOLTAGE CABLES  AND MAINS WIRING     6  Reconnect the lid earthing lead  refit the lid and securely fasten   Test for satisfactory operation  Include all tests detailed in the wiring regulations                                      www formula sound co uk       DRG No                    DATE          FORMULA SOUND LIMITED  UNIT 23  STADIUM BUSINESS CENTRE  NORTH END ROAD  WEMBLEY  MIDDLESEX  HA9 OAT  TELEPHONE  44  0 208 900 0947 FAX  44  0 208 903 8657  www formula sound co uk email info formula sound co uk    E U  CERTIFICATE OF CONFORMITY    We declare that the products listed conform to the following directives and standards  89 336 EEC amended by 92 31 EEC and 93 68 EEC    BS EN 5
9. NT CONNECTED  TO IT READ THE FOLLOWING AND TAKE THE APPROPRIATE ACTION     Installation and connection should only be carried out by a suitably qualified person  and in accordance with local wiring regulations  In the UK strict adherence to  BS7671  IEE Regulations  is essential  All low voltage wiring should be segregated  from mains voltage wiring  unless cables are adequately insulated     The unit should be connected to a single phase supply of nominally 220 240Vac    The fuse fitted is a 10mm x 38mm gl type of 32A rating  a lower current rated   fuse may be fitted if required    If a fuse needs replacing ensure the type  size  amp  rating is correct  In the event of   fuse failure  investigate the cause of failure before replacing the fuse    POWER SHOULD BE DISCONNECTED WHILE FUSES ARE CHECKED OR REPLACED     DESCRIPTION    This unit is essentially a single pole normally open switch  It allows a low voltage  output from the Sentry Lite to control up to 32amps of mains power  The control voltage  is about 12V dc  It is designed for European single phase supplies nominally  220 240Vac  The unit has an internal fuse to protect the contactor  amp  outgoing cabling     The unit should not be used free standing  it must be securely fixed before use    It is only suitable for use indoors  The unit should not be installed in an atmosphere  subject to high humidity  high temperatures or excessive pollution    These units are not designed for use in a domestic environment    INST
10. SENTRY MK2    SOUND LEVEL CONTROL    USERS MANUAL       Sentry MK 2  ENVIRONMENTAL NOISE CONTROL SYSTEM  FUNDAMENTALS    Noise nuisance legislation requires sound levels to be controlled within limits  for licensed premises it  is increasingly a condition of licensing that equipment to control sound levels is in place     Where artists  such as DJ   s or Bands  bring in their own sound equipment the only way to control  sound levels is to control the mains power ring used for the sound equipment     Installing a contactor into the mains power ring  requires qualified electrician  used to supply power to  the sound equipment and using a Sentry MK2 to monitor sound levels and control the contactor  provides control of maximum music levels     The Sentry is designed to monitor sound levels and provide a trigger when a preset sound level is  exceeded  this trigger will normally be used to trip a contactor removing the mains power supply to  the music system  When the Sentry trips the contactor there is a short  about 3 seconds  delay  before the system can be reset  before pushing the reset button always check that it is safe to do so   eg amps turned down so no sudden surge      The Sentry should be mounted opposite the performing area where the performers can see it  It  should be mounted on a solid wall away from doors and some distance from where speakers will be  mounted  If the Sentry is to be mounted on a wooden or plasterboard wall an external microphone is  likely to be 
11. connections  Contact Formula Sound if you are unsure     Led Indicators    Outputs are provided for remote led indicators    MIC TAMPER  LEVEL 2  WARNING  RESET  REQUIRED  If more than two leds are to be connected they share a common terminal  Led current  limiting resistors are not required  Leds may be connected directly  These outputs are also sufficient  to drive a contactor with low voltage interface if required     Timer Adjustment    The period of time that noise  over limit  is tolerated before the unit trips out is variable over the range  of 10   70 seconds  If adjustment is required locate the timer pre set from Drg No 879 and adjust with  a small terminal screwdriver as required  You may have to wait up to 70 seconds for the timing  capacitor to discharge before new timer settings will take place     11    Fire alarm interface    The fire alarm interface jumpers setting the mode of operation are located beneath the display panel   To access first switch off power to the unit  open the perspex display cover and remove the screws  from the display panel  Drop the display panel forward a couple of inches and reach in to release the  ribbon cable connector attaching the display assembly to the main unit     The fire alarm interface connector and settings are located top right corner  on the PCB there is a  legend    FIRE ALRM        To set the mode of operation first set the jumpers for voltage sensing or contacts sensing     VOLTS  SENSE    and    CONT SENSE      If 
12. ency cut off etc  Magnetically operated reed switches of the type used in intruder alarms are  most convenient for this application on doors or a simple emergency switch  If this facility is not  required a wire link must be connected to allow the Sentry to work normally   see Drg No 879   A  front panel indicator shows if the security loop is opened     Tampering    If you find that you have problems with unauthorised persons security screws are available to  replace the cover retaining screws  a special key is also supplied for the fitting and removal of  these screws  Contact FORMULA SOUND sales office for more details     Internal Settings    Several optional settings are available internally  These are shown on drawing Drg No 879     Internal External Microphone Selection and Phantom power    This is accomplished by the position of three jumper plugs on pin headers  Take care to move  jumpers and ensure that they connect correctly  The positions are shown on drawing Drg No 879     Weighting Selection    The position of jumper plugs select the response on the measuring microphone  The positions are  shown on the P C B  Ensure that the jumpers are seated correctly     Special weighting options are possible   contact Formula Sound for further details     External Microphone connection    A 3 way terminal strip is provided for the connection of a remote microphone  The microphone  should be low impedance  balanced and good quality twin screened cable should be used for the  
13. ing the unit to the wall     Use No  10 or 12 screws with round heads 1 5   88mm  minimum length  Brick or masonry walls will  require drilling and plugging in the usual manner     First remove the cover below the display to expose the bottom mounting screw holes  these are  located in the bottom corners of the case  Fit the top centre screw 30 mm down from the required top  case position  leave this screw approx  1 5mm proud of the mounting face     The unit may now be suspended on this screw while the two bottom mounting screw positions are  marked out  ensure that the unit is captive on the screw head so it cannot fall   Fit the bottom two  mounting screws     Check that the unit is secure  cannot fall  and is not loose on the screws     In high risk areas security screws should be utilised to prevent the unit from being removed     Wiring For Applications Controlling the Mains Power     All mains wiring must be installed in accordance with IEEE Regulations  If after reading these    instructions you are not sure how to proceed you should seek help from a qualified    Overview    The Sentry provides outputs to control a contactor or relay which in turn will control the mains supply   This strategy allows the Sentry to be mounted in the most suitable position for noise measuring whilst  the mains switching equipment  the relay or contactor  can be mounted in the most convenient  position for switching the mains power  fuse cupboard  etc      A 32amp fully fused boxed contac
14. lf the unit is to be used in an entertainment venue to control a band or disco use a meter  with either a linear scale or  C  weighting response     The frequency response of the measuring circuit of the Sentry may be selected to be  Linear  Flat  response     C     conventional C scale   Bass  LP filter   300Hz 12dB per octave slope  or A weighting   see Drg No 879      A  weighting is a frequency response curve that resembles the human ear response  It is much more  sensitive in the mid 500Hz   5 kHz region  It is not recommended for entertainment venues as it is  less sensitive to the bass regions and bass regions travel most and annoy neighbours more  Most  industrial applications will need A weighting     SECURITY LABELS ARE PROVIDED  THESE SHOULD BE FITTED TO COVER  THE SCREW HEADS HOLDING THE REMOVABLE COVER IN PLACE AND WILL  REVEAL ANY UNAUTHORISED ATTEMPT TO CHANGE THE THRESHOLDS    ALWAYS FIT SECURITY LABELS AFTER ADJUSTMENTS HAVE BEEN MADE   EXTRA LABELS ARE AVAILABLE FROM FORMULA SOUND IF REQUIRED     Remember that the acoustic characteristics of a venue will change depending on the number of  people in it  Our experience has shown that it is always advisable to take readings when the venue is  in use  It would be a wise precaution to allow in your costings for a site visit during opening hours to  take measurements and make final adjustments     Security Loop    Provision to connect a security loop is provided  This may be required for fire doors alarm or  emerg
15. m as well as operating a contactor to remove the power  supply    The Sentry may also be used as a Stand alone display unit indicating sound pressure levels or in  industrial applications to switch on warning lamps or illuminated signs advising the use of ear    defenders when the safe noise level is exceeded     Our technical department is always on hand to advise when unusual applications are encountered     Operation    The Sentry features a large bar graph VU meter with 23dB range to give a good visual indication of  the noise level in a venue     While the meter is operating in the green section  with even an occasional peak into the red  there is  no cause for concern  Factory set the Sentry has about 20 seconds delay when limit is just exceeded  before power is removed to allow performers time to reduce sound levels     The Sentry will operate within the range 80dB   120dB and may be pre set to anywhere in this range   Provision is included to operate at 2 different levels  for instance at different times of day  This  selection can be performed manually or automatically by a time switch  A front panel indicator shows  when level 2 is selected     If a mains warning lamp is connected it will operate at the same point as the two red sections of the  meter  These are labelled  WARNING      If the noise level is high enough to light the  OVER LIMIT  section of the meter  three red sections   the noise has exceeded the allowable limit  If this is allowed to continue for mo
16. n display is a grey connector strip  see drwg 879 later in manual      To connect LED   s and switch a 5 core wire is required  low voltage dc and low current   a 6 core  microphone cable would be suitable     Connect the    RESET SWITCH    terminals to the Sentry terminals marked    N     Remote reset switch   on drwg 879     12    Connect the LED terminals to the Sentry terminals marked    J     LED INDICATORS  on drwg 879   note LED COMMON is connected to the Sentry terminal marked    EARTH        Contactor  Details of the contactor are shown on drawing 755 towards the back of the manual     AT1 option    An optional add on is available which can manage sound levels  the AT1 connects to the Sentry and  provided the audio is signal is routed through the AT1 before going to the system amplier s  the  Sentry and AT1 will control levels just below the threshold that the Sentry has been set to     Remote display option    A remote display option is available  this is mounted in an identical box but contains only the Sentry  display circuitry and connects to the    Slave display    terminals     Summary    The Sentry will monitor sound levels and provide a trigger when a set sound level has been exceeded  for about 20 seconds  typically the trigger will be used to operate a contactor     In an audio application  music  the Sentry will normally be used where performers bring in their own  equipment  the mains power supply for this equipment will be put under the control of the Se
17. ntacts can be normally closed if required      Timer option    A timer option is available allowing the setting of two different levels at different times of the day or  week  The timer may for example be set to switch to level 2 at 11pm which may be a quieter level     This option is factory fitted  although an external version will be available in the near future  contact  Formula Sound for details     Counter option    The counter option counts the number of times the Sentry has tripped  This option is factory fitted     Mounting Position    The Sentry should be mounted on a flat solid surface preferably where it can be seen by the persons  affected by its use  D J   band  etc   and away from doors  It should be located in a position where it  cannot be tampered with  e g  A minimum of 8 feet  2 5 metres  from the floor  ideally on a wall  facing the sound source  It is not necessary to have a microphone suspended above the band or  dance floor  If the Sentry can hear the sound source above the background noise the unit can be  calibrated accordingly     Avoid positions that are too close to the sound source e g  in a typical concert room with the stage  area at one end the Sentry should be positioned centrally away from the stage at a minimum  distance equal to the stage width  If there is more than one source of sound  e g  several instruments  in a band the Sentry should ideally be at a position equal distance from each instrument   see Fig1     Ideal Position        Se
18. ntry by  means of a mains contactor  Where mains power is to be controlled the mains ring s  are identified  and a contactor s  are installed  by a qualified electrician  to control those rings     In an industrial application the Sentry may be used to indicate ear defenders are required or remove  power to a piece of machinery  An    A    weighting filter will often be used in this situation     The Sentry should be mounted on a solid wall  away from doors and opposite the source of the  sound  The display should be visable to performers or machine operators  If the Sentry cannot be  mounted on a solid wall away from doors then an external microphone can be used     Two levels may be set  eg day and night or weekdays and weekends may require different levels    switching between levels may be done by switch  keyswitch or timer     There is a choice of filters  for music either Linear or Bass will be used  Bass tends to travel and  therefore is a greater cause of noise nuisance  and for industrial    A    weighting should be used     The fire alarm interface allows the Sentry to be interfaced with the fire alarm  The security loop may  be used to trip the system if fire doors are opened     Adding a Formula Sound AT1 to the Sentry can allow the music level to be controlled providing the  music can be routed through the AT1 beofre going to the amplifiers     A simple method of setting the level for a music venue is to play music at the maximum allowable  level  ensure speakers
19. ntry l    At least 2 5m  From Floor level    Fig 1  Distance    A    should never be less than distance    W        Poor Positioning    Position  B   Sentry   EEN Sentry  Better position Poor positio    Fig 2  In Fig 2 the instruments Y  amp  Z will appear louder to the Sentry than instruments W  amp  X  Moving the  Sentry back away from the stage to position  B  will minimise the problem    In order to help solve difficult location problems provision is now included to connect a remote  microphone to the Sentry MK2  See Drg No 879 for more details     7    Cable Entry and Fixing    Read this section fully before proceeding    Customising the box  Cable entry knock outs are provided on the rear and bottom faces of the unit   using the rear cable entry   s can result in a very neat installation  Select the cable entry positions to  be used and remove the appropriate knock outs   A small flat blade screwdriver on the perimeter of  the hole will assist prizing out the blanking plugs   Remove any sharp edges that may damage  cables or use protective grommets  not supplied    NOTE    Use a separate cable entry for mains connections  Always keep low voltage cables away  from mains cables and connections     Fastening the unit  The unit is secured to a wall by 3 screws  not supplied   The top centre screw  locates in a key hole slot on the back of the unit     The Sentry will require a mains power supply that is not controlled by the contactor  this should be in  place before fasten
20. ovable cover plate  below the display    Non reusable security labels are supplied with each unit to help detect unauthorised tampering     Level 2    Level 2 is selected by shorting the 2 marked terminals on the Sentry grey connector strip  Switch may  be via switch or relay etc  the timer option is detailed below  The allowed level at weekends or  evenings may be different so the level 2 facility allows a quick switch     Opening windows and or doors allows more sound out of a venue  setting level 1 about 6dB lower  than level 2 and using magnet relays on doors windows as the level 2 switch means running at level  2  louder  as long as doors windows shut and dropping to level 1 if opened     4    Remote reset options    Remote reset controls are available in either push button or keyswitch format  the reset control can  then be mounted as desired eg behind the bar or in the managers office     Mic Tamper    With Int ernal  mic rophone  selected the internal microphone is monitored for tampering  if Ext ernal   mi crophone  is selected the external microphone is monitored for tampering  A front panel LED  indicator will show MIC TAMPER if the microphone has been tampered with and the Sentry will trip  the contactor  the Sentry will not reset until MIC TAMPER indicator is off     If Mic tamper is illuminated with Internal microphone selected the internal microphone is probably  damaged and you will need to contact your installer or Formula Sound     The Sentry will switch off
21. re than the set time  period  about 20 seconds factory set  the unit will trip and remove the power to the contactor or relay   Visual indication of this is provided above the reset button     When the unit is first powered up the RESET indicator will be lit   wait for a few seconds and press  the reset button  The Sentry will now be reset and ready for normal operation     The action of the timing circuit means that continually exceeding the limit even for short periods may  eventually trip the unit     The unit has to be manually reset to restore power and this will only be possible after a short time   The reset time is determined by the amount by which the unit is driven over limit  e g  tripping the unit  by just exceeding the limit will result in a short period of a few seconds before reset is possible   Tripping the unit by grossly exceeding the limit will require a longer period before reset is possible     NOTE  It is important that a check is made before the unit is reset   Check that it is safe to do so  eg are amps turned down      Audio systems generally need to be powered up in a specific order  In an audio system comprising  of different components amplifiers  mixers  etc  a general rule is to switch power amplifiers off first  and on last to avoid possible loudspeaker damage  Therefore a band or D J  may need to turn off  amplification equipment to protect loudspeakers before the power is restored     All connections and adjustments are located beneath the rem
22. required as wooden plasterboards are prone to vibration which will be picked up by the  internal microphone     In a basic installation a permanent power feed is required to the Sentry which then supplies the  control voltage to the contactor to hold it in  when the sound level exceeds the set level for about 10  seconds or more the Sentry triggers the removal of the control voltage to the contactor  The contactor  opens and the mains supply to the music system is removed     If you are using our Contactor use the low voltage output from the Sentry which is the first  two terminals on the grey connectors  You can use thin low voltage cable  bell wire alarm cable    etc  the current requirement is very low  this connects to the two terminals on the printed circuit board  located at the end of the contactor case  The polarity is not critical     DO NOT CONNECT MAINS INTO THE PRINTED CIRCUIT BOARD CONNECTORS WITHIN THE  CONTACTOR CASE     When power is applied to the Sentry the reset light will be lit and no contactor control voltage will be  present  Resetting the unit will cause the light to go out and the contol voltages to be present     The allowable noise level must be adjusted on site by using the multi turn pre set labelled  ADJ 1 at the bottom left of the circuit board usually 1 2 turns up or down from the factory setting will  provide more than enough adjustment for most applications     The Sentry can have two levels set  if for example  the allowed level is different
23. the fire alarm is applying or removing a voltage then set for    VOLTS  SENSE     if the fire alarm is closing or opening contacts set for    CONT SENSE        If voltage sensing is selected next set voltage applied or voltage removed     V A    or    V R          If contact sensing is selected set for contacts normally closed or contacts normally open  located by  legend    CONTACTS     and    N C     or    N O          Replace the display  the ribbon cable connector is keyed so ensure it goes it the correct way round  if  you feel any resistance when pressing home the connector it may be in the wrong way round      Switch the Sentry on and reset it  perform a fire alarm test to ensure the Sentry trips when the fire  alarm operates     Remote Reset    A remote reset facility can be added by connecting a momentary action push button or key switch   Site this in a Manager s office or behind the bar or other suitable location     Formula Sound offer both remote push button  074P  and remote keyswitch  074K  options in a grey  plastic lighting style surface mount box  Connection of either 074P or 074K is as follows     Open the remote reset box and the connections are on the back of the front panel as shown below     LED COMMON  VE  l     e   e  WARNING LED  VE    el       RESET  SWITCH    RESET REQUIRED                The box contains LED   s that show if the Sentry is tripped  reset required  or if the sound level is near  the limit  warning      Behind the panel below the mai
24. tor with low voltage interface has been designed for use with the  Sentry and is available from Formula Sound Ltd     The Sentry also provides connections to use a mains coil contactor with a maximum coil consumption  of 60VA     Installation    In the room that is to be controlled identify all mains sockets and establish which mains ring  or rings   they are on  Select and install a suitable contactor in that mains ring  if there is more than one ring  you will require as many contactors as there are rings  Ensure the contactor is adequate for the  power rating of the ring s      A 32amp fully fused boxed contactor with low voltage interface has been designed for use with the  Sentry and is available from Formula Sound Ltd  also a dual version is available from Formula Sound  which will control two 32 amp rings     In very large installations  it is a simple matter to make 1 contactor control many others  of whatever current rating is required     Connect the contactor control back to the Sentry using appropriate cable and connections depending  on the type of contactor used     Connections    All connections to the Sentry are located beneath the lower removable front cover  below the  display   On this cover is also mounted the reset button which connects to the printed circuit board  via a 2 pin plug  and temporarily may be easily disconnected   See Drg No 879 for more details     Connect the Sentry to a suitable mains outlet using the terminals labelled    Mains In    and
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
Sr. Proprietário Parabéns! Você acaba de adquirir um  Kodak PX 135-36 Plus-X Pan Black & White  TAFCO WINDOWS NU2-352S-I Installation Guide  ノンエアー式 バータイプイオナイザ  V7 Ultra Slim Folio Stand for iPad, Orange  iss phone 21M取扱説明書  Page 1 Page 2 3規格 (ー) 周波数範囲 ー ー 8~ー 3 6MHz (2  CONDITIONS DE LOCATION (AGB  Eureka 3670G Use and Care Manual    Copyright © All rights reserved. 