Home
Linak
Contents
1. 31 DP1C Desk Panel DP1U Desk Panel 6 DPF1K Desk Panel DPF1M Desk Panel 32 DPT Desk Panel 179 9 WDPL fitting for desk 49 5 33 CBD4 278 247 3 8 8 4 3 2 1 B B wu AC in 5 S CBD5 1 59 a Tw 34 DECLARATION CONFORMITY LINAK A S Smedeveenget 8 DK 6430 Nordborg hereby declares that LINAK Actuator System composed Control Box s CBD4 CBD5 And Linear Actuator s 31xxxH xxxxx50S 084 085 DB6 087 089 and Lifting Column s 012 DL4 DL5 DL6 DL7 DL8 DL9 0110 DL11 And Desk Panel s DP1C DP1K DP1T DPB DPF DPBK DP1L DP1V DPAK DPH1K WDPL1 complies with the EMC Directive 2004
2. E 16 Illegal push on key Release all buttons and activate valid button button combination 23 Electrical connection of the DB4 DL4 system The DESKPOWER system is to be connected as shown on figure 7 Each DB4 is to be connected to the sockets on the control box by means of the motor cables which have an 6 pin plug in each end Finally the mains cable is to be mounted and power switched on wm Please note that the control box must only be connected to the voltage stated on the label CBD4 CBD5 with earth The CBDA CBD5 earth cable to be mounted on the desk construction typically the top frame in a way that ensures good electrical contact The function of the earth cable is to earth the desk and ground static electricity The earth connection does not protect other electrical products If the power cable is damaged it has to be replaced by an authorised CBD4 CBD5 with mains cutoff LINAK service centre to avoid any danger Hook for cable relief Mains cable 7 The cable can both be placed to the left or right on the DL4 Control dongle DUDB Figure 7 24 Initialisation of the DESKLINE DB4 DL4 parallel systems The DESKPOWER system is initialised by pressing the down button once or twice and holding it down until the DB4 DL4 runs into end stop It will then automatically run approx 5 mm out again and hereafter slowly run in again Only release the down button when the movement has completel
3. 6832 7070 Fax 55 11 6832 7060 E mail linakbrasil ig com br www linak com br CANADA LINAK Canada Inc Phone 1 905 821 7727 Fax 1 905 821 4281 E mail info linak ca www linak ca CZECH REPUBLIC LINAK C amp S S R O Phone 420581741814 Fax 420581702452 E mail ponizil linak cz www linak cz DENMARK LINAK DANMARK A S Phone 45 86 80 36 11 Fax 45 86 82 90 51 E mail linak linak silkeborg dk www linak dk FINLAND LINAK OY Phone 358 10 841 8700 Fax 358 10 841 8729 E mail linak linak fi www linak fi FRANCE LINAK FRANCE S A R L Phone 33 0 2 4136 3434 Fax 33 0 2 4136 3500 E mail linak linak fr www linak fr GERMANY LINAK GmbH Phone 49 6043 9655 0 Fax 49 6043 9655 60 E mail info linak de www linak de INDIA LINAK A S India Liaison Office Phone 91 80 2299 6533 Fax 91 80 2224 3863 E mail info linak in gt www linak in IRELAND LINAK UK Limited Phone 44 0 121 544 2211 Fax 44 0 121 544 2552 E mail stephen linak co uk www linak co uk ITALY LINAK ITALIA S r l Phone 39 02 48 46 33 66 Fax 39 02 48 46 82 52 E mail info linak it www linak it JAPAN LINAK K K Phone 81 45 533 0802 Fax 81 45 533 0803 E mail linak linak jp www linak jp MALAYSIA LINAK A S Asian Representative Office Phone 60 4 210 6500 Fax 60 4 226 8901 E mail info linak asia com gt www linak asia com NETHERLANDS LINAK Actuator Syste
4. Fax 57 1 282 1684 E mail servicioalcliente memltda com co www memltda com co INDONESIA PT HIMALAYA EVEREST JAYA Phone 6 221 544 8956 65 Fax 6 221 619 4658 1925 E mail hejplastic div centrin net id IRAN Bod Inc Phone 98 21 88527255 Fax 98 21 88514037 E mail mail bod ir www bod ir MEXICO ILSA S A de Phone 52 55 5388 3960 Fax 52 55 5388 3966 E mail linak ilsamexico com www ilsamexico com RUSSIAN FEDERATION 000 FAM Phone 7 812 3319333 Fax 7 812 3271454 E mail purchase fam drive ru www fam drive ru SINGAPORE SERVO DYNAMICS PTE Ltd Phone 65 6844 0288 Fax 65 6844 0070 E mail servodynamics servo com sg www servo com sg SOUTH AFRICA Industrial Specialised Applications CC Phone 27 11 312 2292 or 27 11 2077600 Fax 27 11 315 6999 www stabilus com SOUTH KOREA UNITEK ENG Phone 82 2 567 0888 Fax 82 2 3453 1177 E mail unitekeng unitekeng co kr www unitekeng co kr UNITED ARAB EMIRATES Mechatronics Phone 971 4 267 4311 Fax 971 4 267 4312 E mail mechtron emirates net ae www mechatronics ae For contact details on other countries please visit wwww linak com or contact LINAK INTERNATIONAL Fax 45 74 45 90 10 E mail info linak com www linak com The user is responsible for determining the suitability of products for a specific application LINAK A S takes great care in providing accurate and up to date
5. Guidance We recommend that our products be disassembled as much as possible and divided into different waste groups for recycling or combustion For example waste can be sorted into metals plastics cable scrap combustible material and recoverable resources Some of these main groups can be further divided into subgroups e g metal can be divided into steel aluminium copper and plastic can be divided into ABS PA PE PP As an example the table below breaks down the different components in LINAK products to various recycling groups Product Components Recycling group Columns Spindle and motor Scrap Actuator Plastic housing Plastic recycling or combustion Cable Cable scrap or combustion PCB boards Electronics scrap Control Box PCB boards Electronics scrap Plastic housing Plastic recycling or combustion Cable Cable scrap or combustion Transformer Metal scrap Handset Plastic housing Plastic recycling or combustion Control Cable Cable scrap or combustion PCB board Electronics scrap By now almost all our casted plastic parts are supplied with an interior code for plastic type and fibre contents if any Main groups of disposal Product main Metal Cable Electronics Plastic recycling Comments groups Scrap scrap scrap or combustin DB4 X X X X DL4 X X X X CBD4 CBD5 X X X X DPXX X X X WDPL X X X 27 Disposal of batteries Details reg
6. can emit waste heat into the surroundings There are no ventilation holes to consider the CBD emits heat through the surface The plug must be visable when the CBD is mounted so that the supply to the CBD can be disconnected at replacement if any The mounting screws on the control box must be fastened with a max torque of 1 Nm The mounting surface to which the control box is attached should have a surface evenness of better than 0 5 mm Operation of the DP The Desk Panel is used to operate the DESKLINE system The DP is available in a number of versions DPA DPB DP1K DP1L DP1U DP1V DPF1K for single parallel drive without memory and DP1U DPF1M for single parallel drive with memory 3 memory positions The two arrow buttons are used for single parallel drive and the last four buttons for memory drive 4 Desk up m Desk down 1 2 3 LS Memory 1 Memory 2 Memory 3 Store memory Single parallel drive lt The arrow buttons start the DL4 DB4 The function is only activated when holding down the button Memory drive 1 2 3 Memory 1 2 and 3 start a memory drive the channel s drive to a preprogrammed position Store memory 5 e 5 5 e Within two sec push either 1 2 3 DPB Desk Panel DP1K Desk Panel DP1L Desk Panel DP1U Desk Panel DPF1M Desk
7. information on its products However due to continuing developments in order to improve its products LINAK products are subject to frequent modifications and changes without prior notice Therefore LINAK cannot guarantee the correct and actual status of said information on its products While LINAK uses its best efforts to fulfil orders LINAK cannot for the same reasons as mentioned above guarantee the availability of any particular product Therefore LINAK reserves the right to discontinue the sale of any product displayed on its website or listed in its catalogues or other written material drawn up by LINAK All sales are subject to the Standard Terms of Sale and Delivery for LINAK A S For a copy hereof please contact LINAK 2 LINAK A S reserve the right to make technical alterations Copyright O LINAK 2009 04 MA M9 02 152 i WE IMPROVE YOUR LIFE
8. the same time either desk up or desk down this will adjust the light intensity Initial press will show the current setting Keep the 1 button pressed during the whole sequence while adjusting up or down Keep a button pressed for more than 800 msec then the button will auto repeat every 100 msec Releasing all buttons stores the new setting Adjusting the light timeout Possible light timeouts are 0 15 sec and off Adjustment procedure Press the 3 button and at the same time either desk up or desk down this will adjust the light timeout Initial press will show the current setting Keep the 3 button pressed during the whole sequence while adjusting up or down Keep a button pressed for more than 800 msec then the button will auto repeat every 100 msec Releasing all buttons stores the new setting Errors Below please find the possible errors which can be displayed The errors will only be displayed when a button is pressed The display blinks while showing the er ror E16 overrules any other error as the detection is registered only in the display and no message is sent to the control box Diagnostic errors The CBD4 version 1 86 or later can send up to 6 different diagnostic error codes at the same time The diagnostic error codes will overrule error states except E16 Diagnostic errors will only appear as long as the button is pressed The dis play will blink EXX and will toggle through the diagnostic errors and send the
9. 108 EC according to following standards EN 61000 4 2 1995 1 2 61000 4 3 2006 EN 61000 4 4 2004 EN 55022 1998 A2 Class B and complies with Low Voltage Directive 2006 95 EC according to the standard EN 60335 1 2002 A1 A11 A12 A2 Household and similar electrical appliances Safety Part 1 General requirements Additional information The system does also comply with the standards DS EN 61000 6 1 2002 Electromagnetic compatibility EMC Part 6 1 Generic standards Immunity for residential commercial and light industrial environments DS EN 61000 6 3 2002 Electromagnetic compatibility EMC Part 6 3 Generic standards Emission standard for residential commercial and light industrial environments Date 2009 04 03 Signature 222 3 John Kling LINAK APPLICATION POLICY The purpose of the application policy is to define areas of responsibilities in relation to applying a LINAK product defined as hardware software technical advice etc related to an existing or new customer application LINAK products as defined above are applicable for a wide range of applications within the Medical Furniture Desk and Industry areas Yet LINAK cannot know all the conditions under which LINAK products will be installed used and operated as each individual application is unique The suitability and functionality of the LINAK product and its performance under varying conditions application vibration load humid
10. BD5 MADE BY LINAK AS DENMARK NOT TO REOPENED BY UNAUTHORI PERSONNEL N The label is printed LINAK 3 La bel for DPA directly on the DPA WE IMPROVE YOUR LIFE Item CBD5P00020A 009 Date 2006 05 09 Uin 230V 50 Hz Pin 500W U Out 18 VDC Op 10 2 min 18 min Label for DPB S W P N 0077429 Ver 1 00 directly on the DPB Lenga CAUTION Not to be opened by unauthorized personne 0 123456 0003 Label for DLA Power Rate 18V 7 3 Amp D le 10 Max 2 min 18 min uty pk and AN po 1zsase 0001 Label for WDPL WE IMPROVE YOUR LIFE WDPL1000 000001 40 05 09 P O 123456 0000 S W P N 0077006 Ver B1 11 MADE BY LINAK DENMARK 4 NOT TO BE OPENED BY UNAUTHOR 280 29 DRAWING APPENDIX DESKLINE DESKPOWER DB4 DL4 System DL4 26 18 CENTER R64 852 CENTER R6 4 80202 L7 m ES o o 4 3 40 E a 3 00 um fn P DETAIL A 98 0 3 560 2 552 05 SEE DETAIL Standard cable length Approx 50 mm Stroke 675 2 mm DB4 For circular guidance Min inner dimension of the smallest profile is 286 mm p 30 DPA DPB
11. BD5 monitors the current consumption on each channel using a special algorithm If the current consumption on one channel is increased more than a predefined slope a collision is assumed and all channels are stopped immediately and all DL DB s will start to run in the opposite direction approx 50 mm This return drive is done automatically and continues with or without any control key pressed for max 2 5 sec The anti collision sensitivity is different in up and downward direction Upwards the force is approx 20 kg Downwards the load will be approx 40 kg the load on the DL DB the desk what is on top of the desk The 40 kg are needed to activate the anti collision function Situations where the anti collision does not work There are situations where the anti collision will not be activated These situations are f the collision happens during the initialisation phase f the collision happens within the first 1000 msec or after the control button has been released f the collision happens between the floor and the table and the load on the desk the weight of the legs are lower than 40 kg f the collision happens over too long time e g if the collision is with a soft object 26 Disposal of LINAK s products As LINAK s customers often ask us how our products can be disposed of or scrapped we have prepared this guidance that enables a classifi cation to different waste fractions for recycling or combustion
12. DESKLINE IMPROVING ERGONOMICS DESKPOWER DB4 DL4 systems LINAK 3 WE IMPROVE YOUR LIFE Contents Preface Safety instructions Before installation reinstallation or troubleshooting Before start up During operation Repairs Manufacturer s declaration Misc on the DESKLINE DESKPOWER system Warranty Maintenance ERE UP The DESKLINE DESKPOWER System iiipin daaa efe p kinase AREE EXE EN IER dana Mounting guidelines for the DESKPOWER DB4 system Mounting guidelines for the DESKPOWER DL4 system Mounting guidelines CBD4 CBD5 Operation of the DPXX Operation of the DP1C Operation of the DPT Mounting of the DPT Operation of the WDPL Calibrating the WDPL Electrical connection of the DBA DLA system Initialisation of the DESKPOWER DB4 DL4 parallel systems Anti Collision Disposal of LINAK s products Labels Drawing appendix Addresses We are delighted that you have chosen a product from LINAK A S LINAK systems are high tech products based on many years of experience in the manufacture and development of actuators electronic control boxes controls and chargers We are also constantly improving our products to meet customer requirements This User Manual will tell you how to install use and maintain your LINAK DESKLINE products We are sure that the DESKLINE products will give you many years of problem f
13. E repairs must only be carried out by authorised LINAK workshops or repairers as special tools must be used and special gaskets must be fitted Lifting units under warranty must also be returned to authorised LINAK workshops Warning A If any of the DESKLINE products are opened there will be a risk of subsequent malfunction Warning The DESKLINE systems do not withstand cutting oil Manufacturer s declaration Implementation with regard to the Community legislation on machinery Directive 98 37 EC attachment II B A S subsidiaries or representatives see back cover prohibit that actuators are put into service until the machinery into which the actuator is to be incorporated has been declared in conformity with the provisions of all relevant Directives Bent Jensen LINAK A S Misc the DESKLINE DESKPOWER system Warranty There is 36 months warranty on the DESKLINE products DB4 DL4 CBD4 CBD5 DP DPA and DPB against manufacturing faults calculated from the production date of the individual products see label LINAK A S warranty is only valid in so far as the equipment has been used and maintained correctly and has not been tampered with Furthermore the system must not be exposed to violent treatment In the event of this the warranty will be ineffective invalid For further details please see LINAK A S ordinary conditions of sale Maintenance Clean dust and dirt on the outside of the sys
14. Panel 13 Operation of the DP1C DP1C cannot be used on the CBD4 with mains cut off Description The DP1C is equipped with a display and memory and is compatible with the CBD4 Advanced software 077402 ver 1 66 or later The DP1 is only available as a 1 channel version for operation of the parallel channels up and down The actual height of the desk is shown in the display The display is of the LED type with a yellow light and 10 mm high digits Desk up Desk down Store memory s e fees Memory 1 Memory 2 Memory 3 Normal operation To run the desk up or down press the UP or DOWN button and keep it pressed until the desk reaches the desired height The display will count up or down while running and after stop it will continually show the current height of the desk Changing between cm and inches Keep the S button pressed for approx 4 sec and the reading will change from the current setting The default setting depends on the type chosen Store a memory position When pressing the store button the display will flash S for 3 sec Within the 3 sec press memory button 1 2 or 3 The display will acknowledge by show ing S1 S2 or S3 for 1 sec To abort a store sequence press the UP or DOWN but ton while the S is flashing or wait the 3 sec until the display automatically returns to show the height of the desk Drive to a stored posi
15. WDPL is connected to the control box under your table Control box WDPL WDPL fitting for desk Figure 11 Display layout WDPL Flashing when activated IN Error Squeeze Store Inch sign US clock E at mode I PM 88 4 digits for height Desk III User Position and clock mode Active in clock and height mode 19 Calibrating the WDPL For the WDPL to function correctly you have to calibrate your system This has to be done before using the WDPL You only have to do this once Action Display view 1 Switch between cm and inch Press and hold and then press 58 Desk User 2 Measure the height from desk to floor If only one desk is connected go to point 4 68 3 Press o and then press Q or Q to select desk Desk User I If only one desk is connected it is not possible to select Desk II or Ill 4 Press and hold and then press WV to adjust the height in the display Example The display will switch from e g 68 to 69 70 71 etc when amp is pressed and held and then is pressed and e g 68 to 67 66 etc when Gen is pressed and held and then V is pressed 5 When the wanted height is shown in the display press and hold and then D The reference height of the desk will now be stored in the Desk User control box When the reference height i
16. a person who is responsible for the safety of these persons Moreover children must be under surveillance to ensure that they do not play with the product ate It is important for everyone who is to connect install or use the systems to have the necessary information and access to this User Manual ud If there is visible damage on the product it must not be installed ate The appliance is not intended for use by young children or infirm MP persons without supervision ate Young children should be supervised to ensure that they do not play MP with the appliance Before installation reinstallation or troubleshooting Stop the DB4 DL4 Switch off the power supply and pull out the mains plug Relieve the DB4 DL4 of any loads which may be released during the work Before start up Make sure that the system has been installed as instructed in this User Manual Make sure that the voltage at the control box is correct before the system is connected to the mains System connection The individual parts must be connected before the control box is connected to the mains See the User Manual for LINAK actuators if necessary During operation f the control box makes unusual noises or smells switch off the mains voltage immediately Take care that the cables are not damaged Unplug the mains cable on mobile equipment before it is moved Repairs In order to avoid the risk of malfunction all DESKLIN
17. arding safe disposal of used and leaking batteries Batteries should be disposed in accordance with appropriate federal state and local regulations LINAK recommends that used or leaking batteries are disposed through local recycling system Please do not throw used or leaking batteries in normal household waste or in nature This will cause damage to the enviroment How to deal with leaking batteries Leaking batteries should be disposed as described above If leaking batteries are discovered in the product the batteries must be removed at once to minimise damage to the product If leaking batteries are left in the product it might become defect It is recommended to use plastic gloves when handeling leaking batteries The contents of a leaking batteries can cause chemical burns and respiratory irritation If exposed to the contents of a leaking battery please wash with soap and water If irritation persists please seek medical attention In case of eye contact please flush eyes thoroughly with water for 15 minutes and seek medical attention 28 Label for CBDA Label for DBA LINAK F3 WE IMPROVE YOUR LIFE Item CBD4C00030A 309 Date 2006 05 09 Uln 230V 50Hz PIn 600W U Out 18 VDC Op 10 Max 2 min 18 min S W P N 0077402 Ver 1 66 rengo Label for DP CAUTION Not to be opened by unauthorized personnel 0 123456 0000 WE IMPROVE YOUR LIFE Item DP1000 000001 P O 129460 0000 E Label for C
18. he mounting screws on the DP DPA or DPB must be fastened with a M max torque of 1 Nm is mounted with a conical dovetail bracket female On the cross ate bar the counterpart of this bracket must be mounted male This bracket E can be ordered at LINAK When mounting the bracket onto the crossbar you must be careful to mount the brackets perpendicular to the crossbar and that the centre dis tance of the bracket fits exactly with the centre distance of the legs in the top frame bore of the desk oblong holes in the top frame give adjustable centre distance When the crossbar is mounted onto the legs it must be tightly fixed with a plastic hammer to obtain the maximum stability The bracket has to be fully welded in both ends not through the holes in the bracket the bracket will bend Do not mount extra brackets in a way that deforms the profiles When designing the desk top frame and placing the control box you have to choose a design a placement that ensures there is no risk of squeezing at the crossbar 11 Mounting guidelines CBD4 CBD5 The control box is to be fastened with 4 screws 3 screws for CBD5 with a head diameter between 8 and 10 mm Out of regard for the tension surface 10 mm is preferable See drawing appendix for placing of mounting holes and the space the CBD takes up CBD4 Control box CBD5 Control box The CBD must not be packed in heat insulating material but must be placed so that it
19. he wanted height is obtained 6 Press and then 1 O or 1 Desk User Position II The position is now stored in the control box To store a new memory position on the same desk go through points 3 to 6 again If the buttons are not activated for 15 sec the clock function will appear in the display 22 Switch to a stored memory position Quick setu On the back of the WDPL you will find a quick guide for storing a memory position Example p Action Display view 1 Press 3 Press and hold 2 Press O or Q until the wanted user is shown in the display O until all desks have reached their memory position The display will show the height of the moving desk for about 15 sec Desk User III Flashing Desk I User Position Position is flashing digits counting from 117 to 88 When the desk has reached the new height position it will stop flashing If the buttons are not activated for 15 sec the clock function will appear in the display Troubleshooting At errors the error code appears from the display The error segment flashes 1 Hz Error Description of the error Trouble shooting code E 01 Position lost Initialize E 02 Overload in upward direction Remove heavy objects from the desk E 03 Overload in downward direction Remove objects that prevents downwards operation
20. ity temperature frequency etc can only be verified by testing and shall ultimately be the responsibility of the LINAK customer using any LINAK product LINAK shall be responsible solely that the LINAK products comply with the specifications set out by LINAK and it shall be the responsibility of the LINAK customer to ensure that the specific LINAK product can be used for the application in question FACTORIES CHINA LINAK Shenzhen Actuator Systems Ltd Phone 86 755 8610 6656 Fax 86 755 8610 6990 E mail sales linak cn gt www linak cn DENMARK LINAK A S Group Headquarters Guderup Phone 45 73 15 15 15 Fax 45 74 45 80 48 Fax Sales 45 73 15 16 13 E mail info linak com gt www linak com SLOVAKIA LINAK Slovakia s r o Phone 421 517563 414 Fax 421 517563 410 E mail jpGlinak sk gt www linak com USA LINAK U S Inc North and South American Headquarters Phone 1 502 253 5595 Fax 1 502 253 5596 E mail info linak us com gt www linak us com SUBSIDIARIES AUSTRALIA LINAK Australia Pty Ltd Phone 61 3 8796 9777 Fax 61 3 8796 9778 E mail sales linak com au gt www linak com au AUSTRIA LINAK GmbH Phone 43 2746 21036 Fax 43 2746 21044 wwww linak at BELGIUM amp LUXEMBOURG LINAK Actuator Systems NV SA Phone 32 0 9 230 01 09 Fax 32 0 9 230 88 80 E mail info linak be www linak be BRAZIL LINAK do Brasil Com rcio de Atuadores Ltda Phone 55 11
21. m to the LINBUS in the CBD For detailed error description and codes please see the appropriate CBD software description Only working with the DP1C from production date 1 february 2006 and onward Error no Description E01 The desk has an unknown position and needs to be initialised E02 Overload upwards has occurred E03 Overload downwards has occurred E16 Illegal keys pressed 15 Operation of the DPT For safety reasons the DPT has a locking function I If the DPT is locked only a bar is lightning in the display To unlock the ud control press 5 for 1 sec When the DPT is unlocked the height will be shown in the display Now the DPT is active for 2 5 seconds When press ing one of the keys you can do your adjustment Hereafter the DPT will be active for 5 seconds but when there are no activations made within the mentioned time slot the DPT will go in to locking mode again Also if you press S for unlocking too long the DPT will unlock but immediately lock again The Touch Desk Panel is used to operate the DESKLINE systems The DPT is divided into parallel and memory drive The two arrow buttons are used for parallel drive and the last four buttons for memory drive Desk up Desk down Store memory uic 1 2 wji N Memory 3 Normal operation To run the desk up or down press the or v butto
22. mounting bracket for the crossbar is mounted on the largest profile The cable is led out at the top of the small profile This means that the column must always be mounted with the largest profile downwards m c ld Screw length Min B 10 mm Max B 15 mm B Figure 1 ate The mounting of the bottom part is analogue to the top part shown in Figure 1 k Table top lt Absorbing material Min desk height Height of the DL4 in the lowest position Y Floor level Figure 2 A suitable desk height in the lowest position can be obtained mounting the lifting unit on a 6 8 mm bottom plate by means of 4 pcs of M6 countersinked screws We recommend you to use screws of min quality 8 8 The thrust moment must not exceed 10 Nm in the top and bottom plate thread 10 Figure 3 Example of how to mount a 2 parallel DESKLINE DESKPOWER DB4 DL4 system ate LINAK recommends that the DESKLINE DESKPOWER DL4 system should z be used in push applications Placement of a monitor directly above the motor may cause malfunction ate of the monitor Magnets inside the motor may interrupt the picture on M the monitor depending on the distance and type of monitor If this is the case the problem may be solved by placing an iron plate tube or another magnetic material somewhat larger than the profile between the motor and the tabletop ate T
23. ms B V Phone 31 76 5 42 44 40 Fax 31 76 5 42 61 10 E mail infoGlinak nl www linak nl NEW ZEALAND LINAK New Zealand Ltd Phone 64 9580 2071 Fax 64 9580 2072 E mail nzsales linak com au www linak co nz NORWAY LINAK Norge AS Phone 47 32 82 90 90 Fax 47 32 82 90 98 E mail info linak no www linak no POLAND LINAK Polska Phone 48 22 500 28 74 Fax 48 22 500 28 75 E mail dkreh linak com gt www linak pl SPAIN LINAK Actuadores S L Phone 34 93 588 27 77 Fax 34 93 588 27 85 E mail linakact linak es gt www linak es SWEDEN LINAK Scandinavia Phone 46 8 732 20 00 Fax 46 8 732 20 50 E mail info linak se www linak se SWITZERLAND LINAK AG Phone 41 43 388 31 88 Fax 41 43 388 31 87 E mail info linak ch gt www linak ch TAIWAN LINAK A S Taiwan Representative Office Phone 886 2 250 80296 Fax 886 2 2508 3604 E mail info linak com tw gt www linak asia com TURKEY LINAK A S Turkey Representative Office Phone 90 312 4726338 59 Fax 90 312 4726635 E mail vozen linak com tr www linak com tr UNITED KINGDOM LINAK UK Limited Phone 44 0 121 544 2211 Fax 44 0 121 544 2552 E mail sales linak co uk www linak co uk DISTRIBUTORS ARGENTINA NOVOTEC ARGENTINA SRL Phone 54 11 4303 8900 89 Fax 54 11 4032 0184 E mail info novotecargentina com www novotecargentina com COLOMBIA MEM Ltda Phone 57 1 334 7666
24. n Error Codes The DPT has capability of displaying error codes for diagnostic feedback Below are possible feedback errors which can be displayed by the DPT The error codes will only be displayed when a button is touched in unlocked mode The display will blink while showing the error E16 overrules any other error since the detection is registered only in the display and no message is sent to the control box For detailed error description and codes please see the appropriate CBD software description Error no Description E01 The desk has an unknown position and needs to be initialised E02 Overload in upwards direction has occurred E03 Overload in downwards direction has occurred E16 Illegal keys are pressed 17 Mounting of the DP1T The hole in the table top has to be made according to the drawing The DPT is mounted in the hole and the two screws on the back side are fastened with a maximum torque of 40Ncm If you do not have a torque screw driver please tighten gently and not more until you can feel a slight resistance Do not use electrical tool Please note d Frame Mounting the DPT into the table top should be done at the end user so the product won t be exposed to any stress which can destroy the product when transported For countersink versions the technician must ensure that the acrylic plate is not put under pressure which will push the acrylic plate out of place The sc
25. n and keep it pressed until the desk reaches the desired height The display will count the height as the table is moving and will continually show the height of the desk after stopping Storing a memory position Touch the S button the display will flash S for sec While the 5 is displayed touch the memory button 1 2 or 3 The display will acknowledge by showing S1 S2 or S3 for 1 sec To abort a store sequence press the A or v button while the S is flashing or wait the 3 seconds until the display automatically returns to show the height of the desk Drive to a stored position Press memory button 1 2 or 3 and the system will start driving to the desired memory position Keep the button activated until the position is reached The display will count the height as it is driving to the memory position Customizing the DPT digital display Adjust the display to show the correct height The DPT will show 68 cm or 24 5 inches as the height of the desk as the default setting It may be necessary to adjust the displayed height due to different thick nesses of desktops etc when the DPT is delivered from the factory To adjust the display touch the S button and the or v button at the same time until the display shows the actual height of the desk Changing between cm and inches Touch the S button for approximately 4 seconds and the unit of measurement will change on the display The default setting depends on the type chose
26. ree operation Before our products leave the factory they undergo full function and quality testing Should you nevertheless experience problems with your systems you are always welcome to contact our service departments or service centres LINAK subsidiaries and distributors all over the world have authorised service centres which are always ready to help you LINAK provides a warranty on all its products This warranty however is subject to correct use in accordance with the specifications maintenance being done correctly and any repairs being carried out at a service centre which is authorised to repair LINAK products Changes in installation and use of LINAK systems can affect their operation and durability Changes must therefore only be made by agreement with LINAK A S and are made at your own risk LINAK A S Safety instructions A Safe use of the system is possible only when the operating instructions are read completely and the instructions contained are strictly observed Failure to comply with instructions marked with the NOTE symbol may result in serious damage to the system or one of its components Persons who do not have the necessary experience or knowledge of the product products must not use the product products Besides persons with reduced physical or mental abilities must not use the product products unless they are under surveillance or they have been thoroughly instructed in the use of the apparatus by
27. rews which are delivered with the product must be used If they have gone lost there shouldn t be chosen new screws which are longer than 12 mm otherwise top and bottom will disconnect If the product has visible damages it shouldn t be mounted The product is IP30 the customers can be sure that fluids dust will not enter the product The front it selves is closed by the acrylic plates adhesive foil Cable release is specified for max 5 kg Remember to remove the protection foil SECTION A A Countersink Min 5 45 Operation of the WDPL The batteries Wired WDPL Install 3 x 1 5 V batteries type AA The batteries are used as a backup of the clock function if the CBD is disconnected from the mains Figure 9 When the batteries are mounted the display will show the clock function in hh mm The clock has to be adjusted See adjusting the clock on page 21 Low battery Change batteries at weak contrast in the display or when the display shows strange symbols misinformation This does not influence the function of the WDPL it is exclusively a sign that the batteries are to be replaced The WDPL will also work without batteries because it will be powered by the control box The WDPL will also work on CBD4 CBD5 with mains cutoff The clock will only be shown if you have battery backup The cable from the
28. s stored the digits will be switched off for 1 sec and back on again If the buttons are not activated for 15 sec the clock function will appear in the display It is not necessary to repeat calibration when changing batteries 20 Adjusting the clock Example Action Display view 1 Press the clock button using a ball pen 24hr mode European time mode is default can be changed to 12hr mode US time mode Changing time mode press AY or WV Press the clock button again to confirm time mode using a ball pen 2 Press A or We adjust hh 3 Press the clock button again to confirm hh 4 Press A or V to adjust mm 5 Press the clock button again to confirm mm Flashing m tebe Flashing T F amp gt 5 a Switches to PM if hh 11 mm is flashing The clock is now activated 21 Store a memory position 3 users can store 3 memory posistions each The connected desks max 3 are to be adjusted individually one at a time Quick setup On the back of the WDPL you will find a quick guide for storing a memory position Example Action Display view 118 If only one desk is connected go to point 4 1 Press 2 Press O or until the wanted desk is shown in the display 3 Press 4 Press Q 1 1 until the wanted user is shown in the display 5 Press Nor V until t
29. st be connected to the middle profil Must be fixed in the bottom plate Figure 3 DB4 fixing points A The guidances must be secured against rotation A The DB4 must not be activated when it is not mounted in guidance due to the risk of squeezing ic We recommend to mount the DB4 so that the upper rail is fastened to Sag the side with the highest moment load Side slides must be adapted so that the DB4 is parallel with the profiles and so that there is an easy slide fit between the DB4 and the inner profile Bugs must be twisted opposite each other in an angle of approx 8096 The friction in the guidance must be max 150 200 N The weight of the top frame the desktop must be larger than the total friction in the guidances Fastening of the DB4 in the middle profile must be strong enough to manage the maximum friction on the middle profile e Customer guidances must be built into the desk with regard to the conditions described in the DLA section Fixing point upper rail The side with the highest moment Figure 4 Example of how to mount the DB4 system ic LINAK recommends that the DESKLINE DB4 system should be used in sag push applications Placement of a monitor directly above the columns may cause malfunc uu tion of the monitor Magnets inside the motor may interrupt the picture on the monitor depending on the distance and type of monitor Mounting guidelines for the DESKPOWER DL4 system The
30. tem at appropriate intervals and inspect them for damage and breaks Inspect the connections cables and plugs and check for correct functioning as well as fixing points ate The cleaners and disinfectants must not be highly alkaline or acidic wu pH value 6 8 Description of the DESKLINE DESKPOWER system Each DESKLINE DESKPOWER actuator column is equipped with a motor and parallel memory drive is ensured by means of software in the CBD4 CBD5 that also takes account of an oblique load on the desk Soft start and stop are also part of this software which ensures a soft start and stop when adjusting the desk Application of the DESKLINE DESKPOWER system Irrespective of the load the duty cycle 10 6 min hour or max 2 min at continuous use stated in the data sheets must NOT be exceeded as this will result in a superheating of the motor and control box Exceeding the duty cycle will result in a dramatic reduction of the life of the system The DESKPOWER system range contains following products 1 control box CBD4 CBD5 DB4 or DL4 1 4 1 exchangeable mains cable motor cables 1 4 1 DP1U DPF1M if memory function is required DP1CAWDPL DPT if memory function and display is required or 1 DPA DPB DP1K DP1L DP1V DPFK Desk Panel without memory Mounting guidelines for the DESKPOWER DB4 system For detailed information on how to mount the DB4 please contact LINAK Sliding point in the inner profile Mu
31. tion Version with GO memory Press memory button 1 2 or 3 The display will flash GO1 GO2 or GO3 for 3 sec Within the 3 sec press the UP or DOWN button and keep it pressed until the desk stops in the stored position Both the Up and the Down but ton will activate memory drive Although e g the memory position is higher than the actual height it will drive upwards when you press the Down button While running to a memory position the display will Show GO1 GO2 or GO3 and when it stops in the stored position the height of the desk will be shown Releasing the UP or DOWN button will abort the memory drive The display will show the height of the desk Version with standard memory Press memory button 1 2 or 3 and the system will start driving to the wanted 14 memory position Keep the button pressed until the position is reached The display will show the actual height during the memory run Adjust the display to show the correct height It may be necessary to adjust the display due to different thicknesses of desktops etc when the DP is delivered from the factory The DP will show 68 cm or 24 5 inches default setting height of the desk At the same time press the Store button and step UP or DOWN until the display shows the correct height Adjusting the light intensity of the LED display Possible light settings are 0 off 25 2596 50 5096 75 75 100 100 Adjustment procedure Press the 1 button and at
32. y stopped ate If the button is released before the sequence is complete then the M initialisation is interuppted and must be started again from the beginning It is sometimes necessary to press the down button twice to start the initialisation this is because the system can be in different modes when the initialisation starts There will be a 1 25 sec delay If an error situation occurs at the end stop positions or DB4 DL4 are changed to another stroke length then CBD4 CBD5 has to be initialised again The first two times the system runs into the outward end stop it will automatically run approx 3 mm back in inward direction e 5 mm The CBD5 can control the DB4 and the DLA in 2 parallel and 3 parallel while the CBD4 can control the DB4 and the DL4 in 2 3 and 4 parallel so that the desk is always kept horisontal 25 Anti Collision only for DL4 DL6 DL9 and DL11 The function anti collision is a new option for the standard CBDA CBD5 advanced control box software version 1 66 and later A system with anti collision can limit material damages on a desk if a collision with a solid object should occur Enabling the anti collision To enable the anti collision function a little plug called a dongle must be mounted in one of the 2 control ports The function is only active when the dongle is mounted If you remove the dongle again you disable the function Method of operation When the DL DB s are running the CBD4 C
Download Pdf Manuals
Related Search
Linak linak desk linak actuators linak bed linak desk control linak standing desk linak battery linak us linak motor linak control box linak dl6 linak dk-6430 nordborg linak la31 linak la25 linak hoyer lift linak bed remote linak la12 linak desk control manual linak cbd6sp00020a-109 linak dl2 linak louisville ky linak la37 linak deskline linak standing desk manual linaker orthodontics tucson