1. Command Prompt Then you could enter the word ping followed by a space then the IP address to check whether it works or not Note Computer and the converter should in the same subnet 10 www widmx com ArtNet POE User Manual 2 2 2 Setby WEB 1 Open a web browser on the computer that is connected to the converter Enter the IP address of the converter into the address bar and press Enter key Your browser will attempt to connect to the converter s configuration page B 192168 17 B ArtNet Configuration ArtNet to DMX 2 Universe output or input RDM functionality Model l rtNet 1024 Name DMX ART IP Address 192 168 1 Netmask 255 255 255 0 Gateway 192 168 1 100 MAC Address 00 1a 19 00 91 08 Firmware Ver ART F112 Password Subnit 11 www widmx com ArtNet POE User Manual 2 Enter your password to access the configuration page The default password is WiDMX And then you could access to the configuration page and change the parameter as per you requirement z 8 Mipy 192 168 17 cgiogin p e B ArtNet Web Console ArtNet Network Settings Ports Settings Restore Factory 255 255255 0 T me ten Logout 12 www widmx com ArtNet POE User Manual 2 3 Test Art Net ArtNet POE has two operating modes Output m
2. W Macro Preset EZ Scope KB Time Code Rdm Node List Change Log Diagnostics 14 www widmx com ArtNet POE User Manual 3 Click the Preset button to enter the DMX output page Select Art Net Manual gt Enter the IP address of the Art Net converter gt Select the Sin Uni gt Click On Then the computer will start to transfer Art Net signal and convert it into DMX signal You can also move the slider to control the channels Dee rest D Pipe Settings Pipe 2 Protocol Manual IP 192 168 001 007 Sub Uni Ben 1 z Output gt u Off On 15 www widmx com ArtNet POE User Manual 3 Applications When the Art Net Converter receives the signal via WiFi or from the Art Net controller it would convert the Art Net signal into DMX signal Therefore it is a perfect way to send and receive DMX universes or to connect multiple lighting controllers via Ethernet especially for lighting equipment that does not have an Art Net protocol 16 www widmx com ArtNet POE User Manual 4 Maintenance Please storage and use the device within required temperature Device may damage if the temperature is too high or too low The device is not water proof Please keep the item and its accessories dry Please do not use it in bathroom or other place with high humidity Do not let water or other liquid seep into the device or it may be damaged Do not p
3. 2 2 1 Set by 0 7 2 2 2 Set by 11 2 3 TEST 2 13 3 16 4 MAINTENANCE 17 Safety Information Please keep the product far away from the heat It should be away from the heater radiator or any other heat source Heat will damage and break the product even worse it may start a fire Please shutdown the product where there are slogans like Explosion Zone May Burst Area and Turn off the wireless transceiver or somewhere such as Hospital Gas Station and Airport It may bring trouble for some medical electronic equipment like hearing aid and cardiac pacemaker and 50 on Please follow the warning notes and safety instructions Please use the attached power adapter It might damage the device if using unapproved power adapter Statement We will keep improving and developing our products We reserve the right to modify and to improve the described item in this document without notice in advance Unless otherwise provided by applicable laws we do not make any type or implied warranties to the accuracy reliability and content of it including but not limited to the warranties of merchantability and the purposes of specific application any case we do not take responsibility on the loss of data property and revenue or any special inci
4. Art Net Converter ArtNet POE User Manual Version 1 0 Thank you for choosing ArtNet POE converter ArtNet POE converter uses standard Art Net Protocol providing bidirectional conversion between Art Net and DMX It provides user friendly configuration tools to read and set parameter It is Power over Ethernet which provides both data and power connections in one cable so equipment doesn t require a separate cable for each need What s more it supports the Remote Device Management RDM protocol facilitating the remote control and modification of parameter of light fixture By this protocol user could access to the fixture on software via network ArtNet POE converter supports automatic IP configuration protocol DHCP and BOOTP or settings via a web browser With ArtNet POE ezConfig program users could active the online lighting application easily within few steps It is user friendly that users could finish the Setup within 30 seconds Complete instructions and product features please read this manual or visit our website at www widmx com Content SAFETY 2 STATEMENT 00000000000000 3 1 INTRODUCTION 0000000000000000 000000 00000 4 1 1 FEATURES esse 4 1 2 5 5 1 3 PACKINGL IS 222228222205 5 2 OPERATING GUIDE 6 2 1 GONNECT LIE 6 2 2 PARAMETER CONFIGURATION 7
5. dental consequential or indirect damages whether the loss caused by any reason The availability of particular products may vary by region Please contact with your local dealer www widmx com ArtNet POE User Manual 1 Introduction 1 1 Features ArtNet POE converter uses standard Art Net Protocol providing bidirectional conversion between Art Net and DMX It is Power over Ethernet PoE which provides both data and power connections in one cable so equipment doesn t require a separate cable for each need What s more it supports the Remote Device Management RDM protocol Standard Art Net protocol 32 bit ARM Processor DMA transfer without delay Adaptive MDI MDIX through crossover cable can work Built in WDT ensure long term stable and reliable work Through ezConfig or web browser to read and set the parameter www widmx com ArtNet POE User Manual 1 2 Specifications e Rate 10 100 Mbps adaptive to MDI MDIX e Connector 8 RJ45 EtherCon e Magnetic Isolation Protection Built in 1 5 KV e Power DC 5 V or POE e Dimension 80 x 70 x 46 mm 1 3 Packing Lis Delivery includes 1 ArtNet POE Converter 1 2 Power 1pcs 3 User Manual 1 www widmx com ArtNet POE User Manual 2 Operating Guide 2 1 Connect 1 Connect the ArtNet POE converter to the computer directly with a RJ45 cable or connect both of them to the Network Switch or Ethernet HUB With th
6. e Auto MDIX technology both through crossover cable can work Note If the Network Switch does not support the PoE it should be powered by 5V DC 2 In normal operation the LNK ACT status indicator would turn on when the data package is transferring the indicator would flash If it is connected to the 100 Mbps network the Speed status indicator would turn on Otherwise it will turn off 3 Connect the converter to the fixture with a DMX cable www widmx com ArtNet POE User Manual 2 2 Parameter Configuration ArtNet POE converter could read and set the parameter by searching via ezConfig or web browser 2 2 1 Set by ezConfig 1 Download the ezConfig the configuration program from our company website Open the ezConfig application Its initial screen is just like the following picture 8 ezConfig ArtNet www widmx com ArtNet POE User Manual EEE Click tho search button it will do a web search to find the MAC addresses of the linked Art Net Converters Choose one of the MAC addresses in the MAC address list and then you could read and set the parameters Read Click the Read button to show the current setting of the Art Net Converters It will read the parameters of the chosen MAC address You could choose another Art Net Converters in the MAC address list to read its parameters Choose one of the MAC addresses and then you could set the parameters as for your requirement Afte
7. lace and use the device in dusty place Please use a soft slightly moist cloth to clean the outer case Never use alcohol acetone or other similar solvent to clean it Please do not attempt to take apart the device and repair it by yourself If the device is detected please contact with the dealer as soon as possible 17
8. ode and Input mode In the Output mode the status indicator of its corresponding DMX port would turn red while in the Input mode turn green In the output mode Art Net signal that is transferred via Ethernet would convert to DMX512 signal in input mode DMX512 signal would convert to Art Net signal and then transfer via Ethernet ArtNet POE converter is a compatible product that supports the software application and controllers that use the Art Net protocol Here take DMX Workshop as an example to test its output 1 Open the DMX Workshop software and then select the Network Interface Card If the computer only one Network Interface Card this window will not appear 13 www widmx com ArtNet POE User Manual IP Address Configuration 052 ArtNet FailOver Available NICs Host Address 192 168 1 100 Netmask 255 255 255 0 Host Address 0 0 0 0 Netmask 0 0 0 0 Host Address 0 0 0 0 Netmask 0 0 0 0 Host Address 0 0 0 0 Netmask 0 0 0 0 Host Address 0 0 0 0 Netmask 0 0 0 0 Host Address 192 168 1 2 Netmask 255 255 255 0 Host Address 127 0 0 1 Netmask 255 255 255 0 Select Network Interface Card Refresh 2 Click OK button and it will have the following interface Transmit Receive Art Net Time MIDI Help Transmit Dmu ReceiveDmx RDM MIDI Data Capture AN Dynamic Data Grid Stress ESI MIDI Rx Network
9. r you are finishing the setting click the Write button to save the parameters of the Art Net converter Click the Exit button or to press the Esc Key to close the ezConfig configuration program www widmx com SET UP ArtNet POE User Manual 1 Follow the guidance of 2 1 and connect the Art Net converter properly Run the ezConfig configuration program and click the Search button to find the Art Net Converters When the program finds the Art Net converter it will show its MAC address in the MAC address list BB ezConfig ArtNet MAC ADORESS Ver ART FII2 MAC ADORESS LST PC PADORESS 192 168 1 100 NETWORK SETTING P MODE OEM CODE 00430 10 Custom P onc PADORESS 192 188 1 7 SUBNET MASK 255 GATEWAY 192 188 1 100 SHORTNAME DUXART LONG NAME www wiam com Search Read PORT 5 PORT Port NUM Net Address Sub Address Port Universe Port 2 Universe Port 3 Universe Port 4 Universe 27 Duxs 2 Bremius 92 mans 12 Ree 40 or www widmx com ArtNet POE User Manual 2 Choose one of the MAC addresses in the MAC address list Then you could read and write the parameter of the chosen converter After you have set the parameter you could click the Read button to check whether it is saved 3 After setting you could open the command prompt 0 test the setting In Windows select Start gt Programs gt Accessories gt