        AV90 Thermo anemometer instruct_AV90 Thermo anemometer
         Contents
1.  display the average air velocity  reading and number of points measured  The anemometer can recorded a total    of 8 points at one time  and calculate the average for the last 8 points     5  Press and hold down the MULTI POINT button or press the RESET button  for 2 seconds to exit and erase recorded readings  or press  HOLD  button to    exit but not erase recorded readings     SPECIFICATIONS AND FEATURES      Portable digital Thermo Anemometer     Simultaneous display of both temperature and air speed     Memory of maximum  minimum and average record for both temperature  and wind speed   D  Air velocity average for multiple points   E  Auto power off function     F  2 meter coiled cable and mounting nut for long extension     GENERAL    Low battery indication  The eel is displayed when the battery voltage drops    below the operating level    Accuracy  Stated accuracy at 23  C   5  C   lt 80  relative humidity  Operating environment  0  C to 50  C at  lt 75  relative humidity  Storage environment   20  C to 55  C at  lt 80  relative humidity  Battery  Standard 9V battery  NEDA 1604  IEC 6F22 006P   Battery Life  200 hours typical with carbon zinc battery  Dimensions  770 H  x 65 5 W  x 35mm D    Weight  390g including battery and probe    MAX MIN Record Mode  Press MIN MAX button to enter the MIN MAX Recording mode  In this  mode  the automatic power off feature    C   F button  amp  UNIT buttons are    disabled  and the measurement period will be set to 2 seconds     Pu
2. OLD key again cancels DATA    HOLD mode  causing hygrometer to resume taking measurements     C   F Scale and Imperial Metric Unit Change    The default setting for measurements is metric units  The temperature scale is  displayed in either degrees Celsius    C  or degrees Fahrenheit    F   To change    the temperature scale  press the   C   F button   Air velocity is displayed in either metric or imperial measurements     To change the air velocity scale  press the UNIT button  In degrees Celsius   C    press UNIT button to cycle between m s  meters per second   Km h  Kilometers    per hour  and Knots     Martindale Electric will carry out routine calibration  on a chargeable basis  if the  instrument is returned  carriage paid  to the address on the final page of this    document  Alternatively  a chargeable collection and return service is available     Repair  amp  Service  There are no user serviceable parts in this unit  Return to Martindale Electric  Company Ltd if faulty  Our service department will promptly quote to repair any    faults that occur outside the warranty period     Storage Conditions   The unit should be kept in warm  dry conditions away from direct sources of  heat or sunlight  with the battery removed and in such a manner as to preserve  the working life of the unit  It is strongly advised that the unit is not kept in a tool    box where other tools may damage it     Warranty   Faults in manufacture and materials are fully guaranteed for 2 years from 
3. THERMO ANEMOMETER    MARTINDALE          OELECTRIC    Trusted by professionals    mode  press the HOLD key to stop the recording of readings  all values are  frozen  press again to restart recording  Press and hold down the MIN MAX  button for 2 seconds  or press the RESET button to exit and erase recorded    readings     2 sec    16 sec  Average Mode   Pressing the 2sec 16sec button sets the measurement period to 2 seconds    AVG 2  is displayed in the lower left hand side corner of the display  The first  reading will hold for two seconds and flash  2  on the display  and then update  every two seconds with average for the last two seconds  The default setting for  the measuring period is 2 seconds  Pressing the 2sec 16sec button again sets  the measurement period to 16 seconds   AVG 16  is displayed in the lower left  hand side corner of the display  The first reading will hold for sixteen seconds  and flash  16  on the display  and then update every two seconds with average    for the last sixteen seconds     Multi Point Average Mode  1  Place the probe head in the area where air velocity is to be measured   Press the HOLD button to take the measurement and enter the data hold mode     The anemometer holds the reading     2  Press the MAX MIN button  The second display will show a count  This    number represents the point that is being recorded   3  Repeat this process until all desired points have been measured and recorded     4  Press the MULTI POINT button  This will
4. date  of invoice and will be rectified by us free of charge  provided the unit has not  been tampered with and is returned to us with its housing unopened  Damage  due to dropping  abuse or misuse is not covered by the guarantee  Nothing in    these instructions reduces your statutory rights     In degrees Fahrenheit    F   press the UNIT button to cycle between ft m  feet per    minute   mph  miles per hour  and Knots     MAINTENANCE    Battery Replacement  1  Power is supplied by 9V  NEDA 1604  IEC 6F22  battery     2  The        appears on the LCD display when a replacement is needed  To  replace the battery  remove the two screws from the back of the meter and lift off    the battery cover   3  Remove the battery from the contacts   4  Remove battery when the unit is to be stored or unused for long periods     5  Do not store unit where it may be subjected to high levels of temperature or    humidity     Cleaning    Periodically wipe the case with a damp cloth  Do not use abrasives or solvents     Martindale Electric Company Ltd was founded in 1928 and  manufactures a large range of electrical test equipment        16th Edition Testers     All In One Testers      Calibration Equipment      Continuity Testers     Electrician   s kits      Full Calibration  amp  Repair Service     Fuse Finders      Digital Clamp Meters     Digital Multimeters     Microwave Leakage Detectors     Motor Maintenance Equipment     Non trip loop testers      Pat testers  amp  Accessories     Phas
5. e rotation      Proving units     Socket Testers       Thermometers  amp  Probes     Test Leads      Voltage Indicators         Specialist Metrohm testers  4  amp  5kV     Specialist Drummond testers    Martindale Electric Company Limited  Metrohm House  Penfold Trading Estate  Imperial Way  Watford  WD24 4YY   Tel   44  0 1923 441717 Fax   44  0 1923 446900    E mail  sales   martindale electric co uk          Website  www martindale electric co uk    E EO     Martindale Electric Co  Ltd  2004       
6. sh MIN MAX key to cycle through the MAX  maximum   MIN  minimum      MAX  MIN  maximum minus minimum  and AVG  average  readings  In this    2    TEMPERATURE    Temperature Scale  Celsius or Fahrenheit user selectable   Temperature Sensor  NTC   Measurement Range   20  C to 60  C    4  F to 140  F   Measurement rate  1 times per second    Resolution  0 1  C      Accuracy   1 0  C  20  C to 0  C  45  C to 60  C   0 5  C 0  C to 45  C   2 0  F  4  F to 32  F  113  F to 140     1 0  F 32  F to 113  F    Air Velocity   Mounting Nut  1 4  x 20  Operating Temperature    Meter  0  C to 50  C  32F to 122  F   Vane  0  C to 60  C  32F to 140  F     WIND VELOCITY    Units Resolution Threshold Range    m s 0 01 0 3 0 0 30 0  ft min 1 60 0 0 5900  knots 0 1 0 6 0 0 58 0  mph 0 1 0 7 0 0 67 0  Km h 0 1 1 1 0 0 108 0    Accuracy   3 FS       OPERATING INSTRUCTIONS    Power Switch    Slide power switch to APO position   APO  will be indicated on the display  The  Auto Power Off mode turns the meter off automatically when it is not used for 10  minutes  When auto power off happens  turn the switch to OFF  Slide the power    switch to APO position to turn on the power again    Back Light   Press  XY  button to turn the Back Light on  To turn the Back Light off press again   DATA HOLD    Press the HOLD key to enter the Data Hold mode  the   H   indicator is displayed   When DATA HOLD mode is selected  the anemometer holds the present readings  and stops all further measurements  Pressing the H
    