Home
AVer F70W User Manual
Contents
1. Sa oa V lt 75m a Qu Anti glare Sheet The anti glare sheet is a special coated film that helps eliminate any glare that maybe encountered while displaying very shiny objects or glossy surfaces such as magazines and pictures To use simply place the anti glare sheet on top of the shiny document to reduce reflected light External Memory Storage AVerVision F70W supports an external SD memory cardfor more image capture and audio amp video recordings AVerVision F70W can detect when there is an external storage media and automatically switch to the last detected storage If no external storage is connected all captured still images will be saved in the built in memory Note Generally you can use the F70W to do video recording for as long as you would like depending on how much SD Card memory is being used up to 32GB Recording is done in 1080p 30fps into an MP4 format A one hour recording could generate a file as large as 1 2 to 1 5 gigabyte Gb of disc space The system will automatically truncate the video file into multiple files once the size reaches 2Gb of space For instance if your 3 hour video recording takes up to 3Gb of space you will have 2 video recorded files being generated the first one 2Gb and the second file 1Gb for a total of 3Gb Insert an SD Card Insert the card with th
2. 39 39 a 39 ON 39 CR 39 40 External Storage 40 Using the RS 232 E T 40 Connect to the Computer 5 232 nennen nennen nsns nans 40 RS 232 Cable 5 2 2 2 21 2 40 RS 232 Transmission 5 2 4 2 1 41 RS 232 Communication Format pp 41 RS 232 Send Command Table pp 42 RS 232 Get Command 47 Troubleshooting 48 Limited Warranty 52 Package Contents Make sure the following items are included in the package WiFi Dongle Software amp Manual CD gA a Power Adapter 12V 3A c 0 eo A ee The power adapter will vary depending on the standard power outlet of the country where it is sold AVerVision 70 Remote Control batteries included Optional Accessories AVer Microscope Adapter Carrying Bag Anti glare Sheet 28mm amp 34mm Rubber Coupler Get Familiar with the AVerVision F70W fig 1 1 Function 1 Camera head Contain the camera sensor 2 Camera lens Focus the image in the camera 3 LED light Provi
3. 24 Navigate the Menu and Submenu pp 25 luco 25 25 CON 25 Auto Image 4 26 27 White 27 E9160 27 ease 28 wie T 28 OA 28 vele sisi MNT 29 29 IST 30 ET 30 ee 30 30 aj 30 ules Un 31 Interval 31 31 F e simol c E T a 31 WU 31 mile NER ___ ___________ 32 32 74 TROUPE 32 TIBS SIE AT eea 32 7 7 PasSsWord pp 33 TOBC 18 AR 33 Machine Name pp 33 N 35 TEM 35 Shs E ET 35 35 SEE DO 35 PROC 35 36 M Hn 36 ED 37 Sde SD ee ES 37 ____________________ eee 37 Slige Bre Eee 37 COST 37 Ge 37 Transfer Captured Images Videos to a 38 Ia 39 OS
4. 1 IMAGE Press MENU button on the remote or control panel 2 Press gt lt to toggle between tabs 3 Press and to choose a selection in the menu list 4 Press to make a selection 5 Use and 4 to adjust the setting make selection 6 Press to enter submenu 7 Press MENU to close the OSD menu Brightness Auto Image Auto Image Adjust brightness level manually between 1 and 64 Contrast Adjust the contrast level manually between 1 and 32 under bright and dark environments 25 Auto Image Brightness Contrast Mode E Color Auto Image Brightness Contrast Mode Effect Auto Image Brightness Contrast Mode Auto Image Mode Select from the various image display settings Text adjust the contrast along the edges making text appear more visible Graphics adjust the gradient of image Microscope automatically adjust optical zoom for microscopic viewing Effect Convert the image into positive true color monochrome black and white or negative Mirror Select to flip the image in Camera mode Advanced Select to set the Auto Image Exposure and White Balance settings Auto Image Select ON or OFF to automatically adjust the white balance and exposure setting and correct the color and exposure compensation 26 Menu Scre
5. Timer Start Pause Stop timer and set the timer duration The timer automatically counts up after the count down reaches zero to show the elapsed time Even when you switch between Playback PC or Camera modes the timer will continue Capture Select to set the capture resolution quality type and interval settings Resolution Select the capture size In 2M setting the capture resolution size is 1920 X 1080 Quality Select the capture compression setting 30 Interval Embedded Embedded Camera Interval Embedded Embedded Camera Interval Embedded Embedded lt 4 capture Single capture one picture only Continuous capture successive pictures Interval Set the time interval for continuous capture The length can be set up to 600 sec 10 min Storage Change the storage location Audio amp video recording can only be saved in SD memory card Format Format to delete all the data in the selected memory USB to PC Camera can be used as a computer webcam or with our bundled software to record video and capture still image Storage transfer the captured pictures videos from the memory to computer hard disk 31 Function Flicker Select between 50Hz or 60Hz Some display devices cannot handle high refresh rates The imag
6. 1412161230 Default Restore all the settings into original factory default English 1024x768 SD Card Profile 1 Profile 1 Execute 4 1 Execute Playback Embedded Execute Embedded Execute WW Embedded Execute Embedded Execute PLAYBACK OFF Embedded Execute Slide Show Display all captured still pictures in an automated slide show The video file will be skipped Interval Set the interval before displaying the next picture The length can be set up to 100 sec Slide Show Effect Select the slide show transition effect Li Slide image Split Vertical Out Checker down Split Horizontal In Blinds Current Storage Select the source of the images Delete All Permanently delete all the data in selected memory source A Warning Message will appear Select YES to continue and NO to stop formatting the storage 2 Transfer Captured Images Videos to a computer This enables you to transfer the captured image from the built in memory or SD toa computer The instruction below MUST be read and followed BEFORE connecting the USB cable 1 MUST set the USB to PC as STORAGE before connecting the USB cable Interval Embedded Embedded Storage 60Hz 2 When Mass Storage Start appears at the lower right corner of the presentation screen you may now connect the USB cable 3 Upon connecting the USB cable the sys
7. to standard 100 240 power outlet The unit automatically goes into standby mode once the power is connected Press o to turn Wall outlet Power adapter Connect to Computer USB Locate the USB port of the computer or laptop and connect it to the PC port of the AVerVision F70W pA USB cable Connect to a Computer with HDMI Input interface Locate the HDMI output port of the computer of laptop and connect it to HDMI in port of AVerVision F70W Make sure the TV RGB switch is set to RGB display computer image press button on the control panel remote control to switch AVerVision F7OW to computer mode For laptop to output display image use the keyboard command FN F5 to switch between the display modes For different command please refer to your laptop manual Connect External Microphone Plug a 3 5mm mono microphone to port The built in microphone on control panel will be disabled when an external microphone is connected The rec
8. To back to WiFi page select OK and press e Machine Name Give a name for the DocCam Use button move to Machine Name and press to call out on screen keyboard Then Use A V 4 gt amp to enter the name This name will be an identity in Sphere application for user to recognize 33 Function Connect Aver Mac Address 04 4f aa 5b a9 d4 IP Address 192 168 20 12 Language m Change and select a different language 1024 768 SD Card Output Display e Set the resolution to display the image on screen This a selection will be disabled in TV output mode 80 Copy image from the built in memory to SD English 1024x768 SD Card Profile 1 Profile 1 Execute Execute Save Setting Save current setting in the selected profile number Only effect mode brightness and contrast settings can be saved English Output Display 1024x768 Backup SD Card Profile 1 Profile 1 Execute Execute Recall Setting Restore the setting back to the selected profile number English 1024x768 0 Card Profile 1 etting 4 1 Profile 1 Information Execute Default Execute 95 Function Information Display the product firmware version information 1024x768 80 Card Profile 1 3 1 0000 07 ASH OBOCPODW DWR 1501211459 OBOCPODW DWS 1501201950
9. rights reserved All rights of this object belong to AVer Information Inc Reproduced or transmitted in any form or by any means without the prior written permission of AVer Information Inc is prohibited All information or specifications are subject to change without prior notice NOTICE SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT PRIOR NOTICE THE INFORMATION CONTAINED HEREIN IS TO BE CONSIDERED FOR REFERENCE ONLY WARNING TO REDUCE RISK OF FIRE OR ELECTRIC SHOCK DO NOT EXPOSE THIS APPLIANCE TO RAIN OR MOISTURE WARRANTY VOID FOR ANY UNAUTHORIZED PRODUCT MODIFICATION THE MARK CROSSED OUT WHEELED BIN INDICATES THAT THIS PRODUCT MUST NOT BE DISPOSED OF WITH YOUR OTHER HOUSEHOLD WASTE INSTEAD YOU NEED TO DISPOSE OF THE WASTE EQUIPMENT BY HANDING IT OVER TOA DESIGNATED COLLECTION POINT FOR THE RECYCLING OF WASTE ELECTRICAL AND ELECTRONIC EQUIPMENT FOR MORE INFORMATION ABOUT WHERE TO DROP OFF YOUR WASTE EQUIPMENT FOR RECYCLING PLEASE CONTACT YOUR HOUSEHOLD WASTE DISPOSAL SERVICE OR THE SHOP WHERE YOU PURCHASED THE PRODUCT Remote Control Battery Safety Information Store batteries in any cool amp dry place Do not dispose used batteries in domestic waste Dispose batteries at special collection points or return to stores if applies Remove the batteries if they are not in use for long period of time Battery leakage and corrosion can damage the remote control dispose batteries safely Do not mix and us
10. AVor WWW aver com AVMer Vision F 0W User Manual Federal Communications Commission Statement Class NOTE This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by tuning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio television technician for help Class A ITE Class A ITE is a category of all other ITE which satisfies the class A ITE limits but not the class B ITE limits Such equipment should not be restricted in its sale but the following warning shall be included in the instructions for use Warn
11. users will see the live image of the DocCam Setting AVerVision F70W This section provides useful tips on how to adjust the AVerVision F70W to meet your needs Storing and Handling The gooseneck design allows you to freely bend the arm and store the camera head in the camera holder Once you have properly secured the camera head to the camera holder you may use the arm to carry AVerVision 70 Shooting The shooting area can view an area of 330x250mm 4 3 size portrait paper If the camera head is in upright position press ROTATE on the control panel or remote control to rotate the image in 180 Auto Image Overhead Light Press LAMP button on the control panel or remote control to turn on and off light Infrared Sensor Aim the remote control at the infrared sensor to operate the unit Mounting the F70W on a Flat Surface Measure and mark the horizontal of 75 mm from the center line distance between the holes on the flat surface as describe in the illustration below Use 2 pieces of M4 0 screws for 6 mm holes and secure the F70W on the flat surface m 11
12. Ox 9 8 7 6 DOA HUC E ET ET ET ET EJ ON OA AO N gt e 9876 RI 5 232 Transmission Specifications Start bit 1 bit Data bit 8 bit Stop bit 1 bit Parity bit None X parameter None Baud rate Communication speed 9600bps RS 232 Communication Format Send Device Code 1 Byte Type Code 1 Byte Data Length Code 1 Byte Data 0 Code 1 Byte Data 1 Code Data 2 Code 1 Byte Receive Device Code 0x53 1 Byte BE Code RS 232 Send Command Table RS 232 Get Command Table Format Send Device Type Length Send Device Type Length Data Receive Data CheckSum Data Receive Data CheckSum Power On Command Get WB Red Value 0x52 OxOB 0x03 0x01 0x52 0x01 0x02 0x53 0x01 0x00 0x53 0x5B 0x5A 0x52 OxOB CD 0 01 RS 232 Send Table RS 232 Get Command Table RS 232 Send Command Table RS 232 Send Table TI ES 5 232 Send Command Table Send Format 0x52 0x03 Data 0 Data 1 Data 2 0x53 CheckSum 1 Success Receive Format 0x53 0x00 0 02 2 0x00 0x52 CheckSum 4 Abnormal Receive Format 0x53 0x00 0x01 3 0x52 CheckSum 5 1 CheckSum xor 0x03 xor Data 0 xor Data 1 xor Data 2 xor 0x53 2 Receive data OXOB Not Command
13. STORAGE ww wa PROFILE RECALL PROFILE 2 PROFILE RECALL PROFILE 3 SLIDESHOW OFF 0x34 0x00 0x00 Ox6f ouau pnest om oo 0 Function Data 0 Data 1 Data 2 CheckSum ZOOM 0 46 0 00 0 00 1 ZOOM 0 47 0 00 0 00 1 0 48 0 01 0 00 0 12 5 232 Get Command Table Send Format 0x52 0x01 Data 0 0x53 CheckSum Receive Format 0x53 0x01 ReData 0 0x52 ReCheckSum 1 1 ReCheckSum xor 0x01 xor ReData 0 xor 0x52 2 Power Status Receive Data 0x51 OxFF 0x01 0x51 5 Function Data 0 CheckSum ReData 0 Red value Blue Value OSB Value 0 255 OFF 2 0 CAMERA MODE Display Status 0x06 5 1 PLAYBACK 2 PC 1 PASS THROUGH Video Output Status 0 HDMI 1 TV Brightness Value Value 1 64 Troubleshooting This section provides many useful tips on how to solve common problems while using the AVerVision F70W General have set up the AVerVision F70W and checked all the connections as specified in the manual but cannot get a picture on the preferred presentation screen 1 Once the power is connected the unit is set to standby mode Press the POWER button to turn on 2 f your display output device is on TV or any analog device please switch the TV RGB dip switch to TV The picture on the presentation screen is distorted or the
14. adapter into this port 2 WiFi Dongle port For WiFi dongle connection 3 HDMI In port Connect an external HDMI source as an input via this port Output the video signal from the main system on an LCD monitor or 4 HDMI Out port 4 LCD DLP projector with HDMI interface using HDMI cable 5 TV Out port Connect the AVerVision F70W to any display device with TV output Connect to a USB port of a computer with a USB cable and use 6 Mini USB port AVerVision F70W as a USB camera or transfer the captured images from the memory source to computer Left Panel fig 1 4 Name Function 1 Set system to standby mode 2 MIC port Connect a 3 5mm plug microphone The built in mic will be disabled when an external MIC is connected to this port Connect to an amplified speaker to playback recorded audio amp video clip RS 232 port Reset The RS 232 jack is used to connect to computer serial port or to any control panel or for centralized control if desire 3 4 Speaker port Control 15 16 17 18 19 N RECORDING CAP DEL FREEZE STOP PLAYBACK AVerVision fig 1 5 Name Function 1 POWER Turn the unit on standby mode 2 o Switch between USB mode and WiFi mode 3 CAMERA Switch the video signal be
15. are blocked F70W cannot access the Wi Fi Please check with your local MIS to unblock Below is a list of ports to look out for 50 I ve done everything listed F70W still does not connect Solution Test your Wi Fi with our Wi Fi tool to check compatibility Please follow these steps 1 2 6 Connect two wireless devices PC iPad or Android to the same Wi Fi network Install WiFi Test Tool by AVer Information Inc on both devices a For PC Download the WiFi Test Tool here b For iPad Download the WiFi Test Tool by AVer Information Inc in the App Store search AVer c For Android Download the WiFi Test Tool by AVer Information Inc in the Google Play Store search AVer Run the WiFi Test Tool on both devices and enter the Remote Device IP of the other device this is the devices IPv4 address Press Start on both devices to begin the test If the test passes your Wi Fi is compatible with the F70W and should have problems connecting If the test fails you may have to change some settings in your router for the F70W to connect Please call our tech support and let us know the error log that is generated from the WiFi Test Tool in order for us to help you troubleshoot the problem Please refer to this demonstration of the WiFi Test Tool if you need help running the test http youtu be v7WjHAFgWFc can see my F70W in the list but cannot see the live view when select the F70W There may be s
16. image is blurry 1 Reset all changed settings if any to the original manufacturer default setting Press MENU then go to SYSTEM gt Default and select YES in the OSD menu 2 Use the Brightness and Contrast menu functions to reduce the distortion if applicable 3 f you discover that the image is blurry or out of focus press the Auto Focus button on the control panel or remote control There is no computer signal on presentation screen 1 Check the cable connections among the display device AVerVision 7 and your PC 2 Connect your PC to the AVerVision F70W first before you power on your computer For notebook repeatedly press FN F5 to toggles between display modes and display the computer image on the presentation screen For different command please refer to your laptop manual The presentation screen does not show the exact desktop image on my PC or Notebook after toggle from Camera to PC mode 1 Return to your PC or Notebook place the mouse on the desktop and right click choose Properties choose Setting tab click on 2 monitor and check the box Extend my Windows desktop onto this monitor 2 Then go back one more time to your PC or Notebook and place the mouse on the desktop and right click again 3 This time choose Graphics Options then Output then Intel amp Dual Display Clone and then choose Monitor Notebook 4 After you follow these steps you should be able to see th
17. is installed operated maintained and used in accordance with AVer specifications Specifically the warranties do not extend to any failure caused by i accident unusual physical electrical or electromagnetic stress neglect or misuse ii fluctuations in electrical power beyond AVer specifications iii use of the Product with any accessories or options not furnished by AVer or its authorized agents or iv installation alteration or repair of the Product by anyone other than AVer or its authorized agents Disclaimer of Warranty EXCEPT AS EXPRESSLY PROVIDED OTHERWISE HEREIN AND TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW AVER DISCLAIMS ALL OTHER WARRANTIES WITH RESPECT TO THE PRODUCT WHETHER EXPRESS IMPLIED STATUTORY OR OTHERWISE INCLUDING WITHOUT LIMITATION SATISFACTORY QUALITY COURSE OF DEALING TRADE USAGE OR PRACTICE OR THE IMPLIED WARRANTIES OF MERCHANTABILITY FITNESS FOR A PARTICULAR PURPOSE OR NONINFRINGEMENT OF THIRD PARTY RIGHTS Limitation of Liability IN NO EVENT SHALL AVER BE LIABLE FOR INDIRECT INCIDENTAL SPECIAL EXEMPLARY PUNITIVE OR CONSEQUENTIAL DAMAGES OF ANY NATURE INCLUDING BUT NOT LIMITED TO LOSS OF PROFITS DATA REVENUE PRODUCTION OR USE BUSINESS INTERRUPTION OR PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES ARISING OUT OF OR IN CONNECTION WITH THIS LIMITED WARRANTY OR THE USE OR PERFORMANCE OF ANY PRODUCT WHETHER BASED ON CONTRACT OR TORT INCLUDING NEGLIGENCE OR ANY OTHER LEGAL THEORY
18. 0x03 8 ID error 0 01 CheckSum error 0x02 Function fail 0x04 4 CheckSum 0x00 xor 0x02 xor 2 xor 0x00 xor 0x52 5 CheckSum 0x00 xor 0x01 xor 3 xor 0x52 6 Standby Mode Receive Data lt 0x51 OxFF 0x01 OxOB 0x51 4 Power On Mode Data No Data Return 7 Standby Mode Data 0x51 0x00 0x01 OxOB 0x51 Ox5B Power On Mode Receive Data 0x53 0x00 0x02 OxOB 0x00 0x52 Ox5B Function Data 0 Data 1 Data 2 CheckSum 001 001 0x00 ob TIMER START oa TIMER PAUSE 0x08 0 01 0 00 0 52 TIMER STOP 0x08 0x02 0 00 0 51 qmesrme _ TIMER SET TIME 0 08 0 03 120 1 Function Data 0 Data 1 Data 2 CheckSum PLAYBACK DELETE PLAYBACK FULL SCREEN MIRROR OFF 0 00 0 00 0 55 MIRROR ON ROTATE O OxOF 0x00 0x00 0x54 EFFECT COLOR 0x10 0x00 0x00 Ox4b EXPOSURE AUTO 0x13 0x00 0x00 0x48 WHITE WHITE BALANCE BLUE DECREASE BLUE DECREASE 0x16 0x01 0x00 FORI WHITE BALANCE RED INCREASE WHITE BALANCE RED DECREASE 0 00000 60Hz 0 18 0 01 0 00 0 42 SPOTLIGHT OF SPOTLIGHT ON Function Data 0 Data 1 Data 2 CheckSum VISOR ON Ox1D 0x01 0x00 0x47 VISOR SHADE 50 dark OF 0x01 0 23 0 00 0 00 0 78 VOL INC 0 26 0 00 0 00 Ox7d Function Data 0 Data 1 Data 2 CheckSum RESOLUTION 1280 800 4 PN CONNECT MASS
19. E ER ER ESERESERERERER ERU ERE EI 777 52 Connect SSID Aver Address 04 4f aa Sb a3 d4 IP Address 192 168 20 12 Toggling between WiFi mode and USB to Mode The F70W HDMI output is always on however the camera can only be put into either USB to computer mode when the USB cable is connected to a computer or WiFi mode When the WiFi button on the front panel of the camera is not toggled the camera is always in USB to PC mode whenever the cable is connected to the computer However once the WiFi button is toggled assuming the WiFi setting is complete and correct the camera goes into WiFi mode and will disconnect the existing USB connection to the computer In WiFi mode you can still connect to the camera via Wireless Streaming through the AVer PC MAC software or Tablet computer Connect F70W with a Tablet Device This function allows the user to stream present annotate record and share live images via a tablet device The following instruction figures use an iPad as an example 1 Please make sure the 7 and tablet are connected to the same AP on your WLAN network 2 Install Sphere application on the tablet Run Sphere application In Sphere user will see the DocCams that Sphere has found 4 Select the DocCam and select Start to make a connection 5 After connection is successful
20. EVEN IF AVER HAS ADVISED OF THE POSSIBILITY OF SUCH DAMAGES AVER S TOTAL AGGREGATE LIABILITY FOR DAMAGES OF ANY NATURE REGARDLESS OF FORM OF ACTION SHALL IN NO EVENT EXCEED THE AMOUNT PAID BY YOU TO AVER FOR THE SPECIFIC PRODUCT UPON WHICH LIABILITY IS BASED Governing Law and Your Rights This warranty gives you specific legal rights You may also have other rights granted under state law These rights vary from state to state For warranty period please refer to the warranty card
21. d and microscope adapter are on the same side to connect and twist clockwise for the arrows to meet and lock Connect F70W to WLAN The F70W can connect to your WLAN network me WiFi function 1 Press Menu button RECORDING gt CAP DEL FREEZE STOP PLAYBACK AVerVision F70W 2 Select WiFi setup page WiFi connect fail Current Status USB Mode Connect to PC Only Machine Name WirelessCam 3 Select Connect and press WiFi connect fail Current Status USB Mode Connect to PC Only Machine Name HirelessCam 4 n AP setting submenu select SSID AP that the F70W has found on your WLAN Press and use to select Press to confirm the selection 5 Enter the Password of selected AP Use V move to the Password column and press to call out on screen keyboard to enter the password Note Show Password is enabled by default User can see the password while entering 6 After entering password select Connect and press to make a connection with selected AP To disconnect WiFi connection select Disconnect and press e To memorize the AP account enable Remember Me function By default this function is enabled 7 When AP information is displayed the connection is successful Connect WiFi scan successful Remember Show Password vie LA LE E
22. de light to enhance the lighting condition 4 Flexible arm Provide adjustable viewing coverage 5 Left panel Connections for RS 232 microphone speaker and reset button 6 Control panel Easy access to various functions 7 IR sensor Receive remote control commands Connections for power RCA external display device WiFi dongle HDMI input HDMI output and USB to PC Connections for the camera head holder SD card TV RGB display output switch and antitheft Kensington security lock compatible slot 10 Built in MIC Record audio when recording video clip The recorded sound will be in monophonic 8 Rear panel 9 Right panel Right fig 1 2 Function 1 Camera Holder Hold the camera head for storage 2 50 slot Insert the SD card with the label facing up 3 TV RGB switch TV switch to output display video from RCA to HDMI OUT 4 Antitheft Slot Attach a Kensington compatible security lock or antitheft device Rear Panel HDMI OUT TV OUT USB Lo 1 2 3 4 fig 1 3 Function 1 DC12V Connect the power
23. e contact facing down until it reaches the end To remove the card push to eject and pull the card out The supported SD card capacity is from 1GB to 32GB FAT32 We recommend using SDHC card with class 6 or above for high quality recording wats f lt Ug Fc SD Card 50 There 5 tabs the OSD menu IMAGE PRESENTATION SETTING WIFI SYSTEM In Playback mode you can access PLAYBACK OSD menu to enable the Slide Show feature and modify Slide Show interval and transition setting if desire For TV output the RESOLUTION will be disabled in SETTING menu list PRESENTATION Spotlight Execute Brightness Contrast Visor Execute Split Screen Execute Mode Effect Mirror Advanced Auto Image Focus PRESENTATION SETTING WiFi Capture Quality 4 1 Connect Storage Embedded WiFi connect fail Format Embedded USB to Camera Current Status 188 Mode Connect to PC Only Flicker Machine Name WirelessCam SETTING SYSTEM PLAYBACK Language 4 English Slide Show Interval Output Display 1024x768 Backup SD Card Effect Current Storage Save Setting Profile 1 Delete All Execute Recall Setting Profile 1 Information Execute Default Execute SYSTEM PLAYBACK 24 Navigate the Menu and Submenu Brightness Contrast Mode Effect Mirror Advanced
24. e old and new batteries Do not mix and use different types of batteries alkaline standard carbon zinc or rechargeable nickel cadmium Do not dispose batteries in a fire Do not attempt to short circuit the battery terminals Table of Contents Package 1 Optional Accessories ee 1 Get Familiar with AVerVision F70WV ee 2 3 3 ER 4 Corin Pan 5 Remote Control pe 7 Making Connections pp 10 Set the TV RGB Switch Setting 10 Connect to a Monitor or LCD DLP Projector with HDMI Output interface 10 Connetti to bm mm 11 Connecting the Power 11 Connect to a Computer via 12 Connect to a Computer with HDMI Input interface 12 Connect an External pp 13 Connect an Amplified Speaker pp 13 Connect to a pp 14 Connect F70W to WLAN ee 15 between WiFi mode and USB to PC 17 Connect F70W with a Tablet Device ee 17 Setting Up AVerVisiOn FLOW ee 19 and Handling RR LEES 19 SOO ING 20 Overhead NECI 21 mirar d Senso sed 21 Mounting the F70W on Flat Surface pp 22 SNC OU euin UE 22 External Memory Storage 4 23 23 edil
25. e same desktop image on your PC or Notebook as well as on the presentation screen F70W Wi Fi connection shows None the OSD menu Press Menu go to the Wi Fi setting page to connect and select Rescan to have the system re scan the airwaves again There s still no SSID detected on the F70W after re scanning Please check the WiFi Dongle and make sure it is properly inserted into the F 0W Make sure when the system is started the dongle emits a blue light Otherwise please check the WiFi Router to make sure it is running You may have to check with your local system administrator to determine the nature of the problem and call AVer tech support The F70W is connected to my PC via the USB cable but I still can t see the live image on Sphere2 Please check the F70W onboard keypad and make sure the WiFi LED i is turned off if itis showing a constant blue color please press pp to turn it OFF Then re open Sphere2 and select the camera from the Visualizer icon as indicated in the picture below Visualizer AVer Classroom Technology Solutions Enhancing 1 1 Curriculum and Device Management 2015 Winter Spring j T 2 E The F70W is streaming to my iPad and PC but am experiencing live video that is not smooth eg missing frames There are a lot of possible variables affecting the WiFi performance o Please check and use the 5G bandwidth on your WiFi router i
26. e selected picture video Playback mode Making the Connections Before making connection make sure the power of all devices are turned off If you not sure on where to connect simply follow the illustrated connections below and also refer to the user manual of the device you are connecting the AVerVision F70W with Set the TV RGB Switch Setting The TV RGB switch determines the display output selection Switch it to RGB right to output signal using HDMI connection and TV left to output signal using RCA connection see fig 1 2 ft 3 Switch TV OUTPUT VIDEO IN Connect to a Monitor or LCD DLP Projector with HDMI Output interface Locate the HDMI input port of the display device and connect it to HDMI out port of AVerVision F70W Make sure the TV RGB switch is set to RGB HDMI monitor HDMI cable LCD DCP projector Connect to TV Locate the Video input port of the TV or Video equipment i e VCR to record your presentation and connect it to RCA jack of RCA cable m m ic qm 3 cable optional WA VIDEO Television VCR Connecting the Power Connect power adapter 12V 2
27. e will flicker a couple of times as the output is switched to another refresh rate Interval Embedded Embedded Camera WiFi Menu Screen Function Me Select enter Password of AP and make connection with selected Select AP Press to expend AP list that F7OW has detected on you LAN network Use A and buttons to move to the AP that you want to select Press to confirm WiFi Connect WiFi scan successful Remember Me Show Password WiFi Connect SSID Aver Mac Address 04 4f aa 5b a9 d4 IP Address 192 168 20 12 Current Status USB Mode Connect to PC Only Machine Name 4 HirelessCam Enter Password Use button move to password column Press to call out on screen keyboard Use A V 4 amp to select the password Use the Back key to delete unwanted characters When is done select Enter to complete If you want check password during enter password mark Show Password option AP Setting Password Connect Disconnect Remember Show Password Connect AP Use button move to Connect and press to start connection When connection is successful the AP information is displayed SSID Aver Mac Address 04 4f aa 5b a9 d4 IP Address 192 168 20 12 To disconnect select Disconnect and press To remember this AP account mark Remember Me
28. elect to run cancel the Spotlight Press to move to the next selection Shade set the opacity level of the area outside the box The shaded area will completely turns black when it is set to level 100 Press to move to the next selection Color select the Spotlight frame color Press to move to the next selection 15 SPOTLIGHT OK press for the setting to take effect If you select ON the frame will appear and blink use A V 4 8 gt buttons to adjust the frame size and press to set the desired size and OFF will close the submenu To turn off Spotlight press again 16 SPLIT Divide the screen into two side SCREEN displays the live image from the built in camera and the other side displays 8 thumbnail size picture video from the memory 17 MODE Select from 3 type of modes Text adjust the contrast along the edges making text appear more visible Graphics adjust the gradient of image Microscope automatically adjust fig 1 6 optical zoom for microscopic viewing 18 TIMER Call the Timer submenu Select to Start Pause Stop the timer countdown and set the timer duration gt OK 19 5 Playback mode Play Pause video playback 20 LAMP Turn the overhead light on off 21 BRIGHTNESS Adjust the brightness 22 DEFAULT Reset to factory default setting 23 DEL Delete th
29. en Function Exposure Select the exposure setting AUTO automatically adjust the camera exposure and the amount of light required MANUAL manually adjust the exposure level The exposure can be adjusted up to 99 White Balance Select the White Balance setting for various light conditions or color temperature AUTO automatically adjust the white balance MANUAL manually adjust the red and blue color level The color level can be adjusted up to 255 Focus Manually adjust the focus Presentation Function LEM HE Spotlight Spotlight overlays a frame on the presentation screen You can move the Spotlight around the presentation screen using the 4 amp gt buttons Select Execute to call the Spotlight submenu ON OFF select to run cancel the Spotlight Press to move to the next selection Shade the opacity level of the area outside the box The shaded area will completely turns black when it is set to level 100 Press to move to the next selection Color select the Spotlight frame color Press to move to the next selection press for the setting to take effect If you select ON the frame will appear and blink use 8 gt buttons to adjust the frame size and press to set the desired size and OFF will close the submenu Visor Visor covers the presentation screen The upper part of the presentation
30. f supported The F7OW supports 2 4GHz 5Ghz and up to the 802 11ac standard e If you use the Sphere2 software go to the Sphere2 Options gt WirelessCam bit rate setting and toggle the setting down to perhaps 1 24Mbps using less bandwidth You have similar options available on the iPad or Android tablet AVer app Power Network LED light is steady and able to see IP address screen as assigned by my Wi Fi router but my F70W is not detected by the software 1 Make sure your computer tablet is connected to the same Wi Fi networks same SSID as the F70W If it not may need to use the IP search method to connect the F70W the IP address See 2 below If it is not convenient to open the access ports You can still connect to the F70W the IP address of the F7OW Screen below shows where you would punch in the IP of the F70W Sphere2 Options Image White WirelessCam settings Choose type of WirelessCam L IP search for WirelessCam Eka Flicker 50Hz 9 60Hz Adding TabCam to Wi Fi network Advanced setting WirelessCam s bit rate setting 0 16 mbps 4 8 mbps Always check if there is a new WirelessCam firmware for update x 8s 3 Security software firewall anti virus installed on your computer be blocking communication between the F70W computer tablet Your Wi Fi router also may be blocking some TCP UDP ports When these ports
31. ing This is a class A product In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures CE Class A EMC This product is herewith confirmed to comply with the requirements set out in the Council Directives on the Approximation of the laws of the Member States relating to Electromagnetic Compatibility Directive 2014 30 EU Warning This is a Class A product In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures to correct this interference DISCLAIMER No warranty or representation either expressed or implied is made with respect to the contents of this documentation its quality performance merchantability or fitness for a particular purpose Information presented in this documentation has been carefully checked for reliability however no responsibility is assumed for inaccuracies The information contained in this documentation is subject to change without notice In no event will AVer be liable for direct indirect special incidental or consequential damages arising out of the use or inability to use this product or documentation even if advised of the possibility of such damages TRADEMARKS AVer is a trademark owned by AVer Information Inc Other trademarks used herein for description purpose only belong to each of their companies COPYRIGHT 2015 AVer Information Inc
32. interruptions or that the Product is suitable for your purposes Your exclusive remedy and the entire liability of AVer under this paragraph shall be at AVer s option the repair or replacement of the Product with the same or a comparable product This warranty does not apply to a any Product on which the serial number has been defaced modified or removed or b cartons cases batteries cabinets tapes or accessories used with this product This warranty does not apply to any Product that has suffered damage deterioration or malfunction due to a accident abuse misuse neglect fire water lightning or other acts of nature commercial or industrial use unauthorized product modification or failure to follow instructions included with the Product b misapplication of service by someone other than the manufacturer s representative c any shipment damages such claims must be made with the carrier or d any other causes that do not relate to a Product defect The Warranty Period of any repaired or replaced Product shall be the longer of a the original Warranty Period or b thirty 30 days from the date of delivery of the repaired or replaced product Limitations of Warranty AVer makes no warranties to any third party You are responsible for all claims damages settlements expenses and attorneys fees with respect to claims made against You as a result of Your use or misuse of the Product This warranty applies only if the Product
33. lue Camera can be accessed wirelessly now Increase the image magnification in camera and picture playback mode Solid Green Battery is over 40 Solid Orange Battery is between 20 40 Solid Red Battery is between 20 5 Flashing Red Battery is lower than 5 Solid Red Power plug is connected and battery is charging Solid Green Battery is fully charged OFF Power plug is not connected Remote Control The remote control requires two 2 AAA size batteries Supplied make sure batteries are installed properly before use You can access all the features of AVerVision F70W with the remote 1 POWER Turn the unit on 2 CAMERA Camera mode displays the video signal from the built in camera 3 RECORD Start Stop audio amp video recording Video recording can only be saved either in a SD memory card 4 CAPTURE Capture still image in Camera mode In continuous capture mode press this button again to stop 5 VISOR Call the Visor submenu Visor covers part of the presentation screen and allow presenter to reveal the material as desire In the Visor submenu the following options are available fig 1 6 OK ON OFF select to run cancel the Visor Press to move to the next selection Shade set the opacity level of the covered area The shaded area will completely turns black when it is set to level 100 Pres
34. ome signal strength issues with the Wi Fi connection Please go through the following steps 1 If your WiFi supports 5GHz radio please connect to the 5GHz instead of the more crowded 2 4GHz There may be other devices using your Wi Fi network at the same time Bandwidth usage packet loss and other connection elements may cause the poor video quality If you are connected via the Sphere2 PC MAC software reduce the bandwidth usage by toggling the bandwidth setting Sphere2 Options gt WirelessCam gt WirelessCam bitrate Settings Sphere2 Options WirelessCam settings Choose type of WirelessCam Limited Warranty For a period of time beginning on the date of purchase of the applicable product and extending as set forth in the Warranty Period of AVer Product Purchased section of the warranty card Information Inc AVer warrants that the applicable product Product substantially conforms to AVer s documentation for the product and that its manufacture and components are free of defects in material and workmanship under normal use You as used in this agreement means you individually or the business entity on whose behalf you use or install the product as applicable This limited warranty extends only to You as the original purchaser Except for the foregoing the Product is provided AS IS In no event does AVer warrant that You will be able to operate the Product without problems or
35. orded audio will be in monophonic sound Microphone Connect an Amplified Speaker Plug a 3 5mm plug amplified speaker to Xx port Only the audio from the video playback is supported We recommend connecting an amplified speaker to the Audio output port Take caution when using earphones Adjust the volume down on the remote to prevent hearing damage due to loudness Amplified speaker Connect to Microscope Connect the AVerVision F7OW to a microscope enables you to examine microscopic objects on a big screen 1 For the eyepiece we suggest using 6 Change the image display mode to Microscope Press MENU gt select IMAGE tab gt select MODE gt select microscope and press e Aim the camera head at the farthest point and press AUTO FOCUS Adjust the focus of the microscope Select the appropriate rubber coupler size for the microscope eyepiece and insert it in the microscope adapter Remove the microscope eyepiece from the microscope and connect it to the microscope adapter with the rubber AS Microscope coupler inserted Fasten the 3 bolts until the adapter secures eyepiece AM Microscope eyepiece 15 5mm eye relief or higher Attach the microscope adapter to the AVerVision camera head Then connect it to the AVerVision and microscope Make sure the arrow the camera hea
36. s to move to the next selection OK press for the setting to take effect If you select ON upper part of the presentation screen is slightly exposed Use the 4 amp gt buttons to reveal more of the covered area and OFF will close the submenu VISOR To turn off Visor press 5 again 6 ROTATE Rotate the image by 180 in Camera mode and Playback mode 7 MENU Open and exit the OSD menu 8 46 and zoom in image above digital zoom level in both live and playback mode Select options in OSD menu Use A amp V to increase and decrease the video playback volume Use 48 to play the video backward and forward Move the Spotlight frame and Visor screen cover 9 AUTOFOCUS Adjust the focus automatically 10 ZOOM Increase decrease the image magnification in camera and picture playback mode 11 ZOOM RESET Reset zoom level to 100 12 PLAYBACK View the captured picture video from the memory in 16 thumbnail images fig 1 6 13 PC 1 2 PC mode displays the video signal m from the HDMI input port of F7OW 14 FREEZE Freeze live images STOP Stop video playback 15 SPOTLIGHT Call the Spotlight submenu Spotlight overlays a box frame on the presentation screen You can adjust the box size and move it around In the Spotlight submenu the following options are available ON OFF s
37. screen is slightly exposed Use the A V 4 8 buttons to reveal more of the covered area Select Execute to call the Visor submenu PRESENTATION Execute Execute Execute PRESENTATION Execute Execute Execute In the Visor submenu the following options are available Visor ON OFF select to run cancel the Visor Press to move to the next selection Shade set the opacity level of the covered area The shaded area will completely turns black when it is set to level 100 Press to move to the next selection OK press for the setting to take effect If you select upper part of the presentation screen is slightly exposed Use the A V 4 amp gt buttons to reveal more of the covered area and OFF will close the submenu Split Screen Divide the screen into two parts Half of the screen displays the 8 thumbnail images and the other half display the image from the AVerVision F7OW camera Select the display location of the 8 thumbnail playback images Select OFF to cancel Split Screen Left Right Top Below Select the thumbnail playback screen location and show the thumbnail playback screen at the corner of the screen to recall the captured image from the memory in Camera mode Select OFF to cancel PIP Lower Upper Left Upper Right Lower 29 SETTING 4 Quality Embedded Embedded
38. tem automatically detects the new removable disk You can now transfer the captured image s from the F70W built in memory to the computer hard disk Technical Specifications Image Optics Auto Manual Compatibility Wireless Security Supports WEP AES TKIP and AES TKIP 802 1x Power DC 12V 3A 100 240V 50 60Hz 16 8 Watts lamp off 18 Watts lamp on Lighting Input Output HDMI Output HDMI s Speaker Phone Jack Dimension Operating 380mm 200mm 525mm 2mm include rubber foot Folded 305mm x 230mm x 73mm 2mm include rubber foot Weight 2 65 kg about 5 84165 External Storage Secure Digital 7 SDHC 1 32GB 32 Using the RS 232 Interface AVerVision F70W can be controlled using a computer or any centralized control panel through RS 232 connection The command code for RS 232 is provided for the system integrator to be able to incorporate it with the system program Connect to the Computer RS 232 Locate the RS 232 port of the computer and connect it to RS 232 jack of RS 232 cable 5232 cable not supplied RS 232 Cable Specifications Make sure the RS 232 cable matches the cable specification design PC COM Port p O osse RXD DSUB 9P male TXD AVerVision RS 232 Port TXD RXD DSUB 9P Female 543 2 4 ES SG O O O O QO DSR O O 0 0 RTS CTS 5432 1 p O O Xr
39. tween camera and computer from the HDMI IN port 4 Reduce the brightness of live view 5 LAMP Turn the overhead light on off 6 FREEZE STOP Pause or resume image display in Camera mode Stop audio amp video playback in Playback mode 7 4 8 gt Select options in OSD menu Use amp to increase and decrease the video playback volume Use 4 amp to play the video backward and forward Move the Spotlight frame and Visor screen cover 8 MENU Open and exit the OSD menu 9 RECORDING Start Stop audio amp video recording Audio and video recording can be saved on a SD card only See External Memory Storage 10 e Adjust the focus automatically Make a selection in Playback mode and OSD menu Start Pause video playback 11 CAP DEL 13 ao 15 indicator 16 me 18 Battery 19 Capture picture in Camera mode In continuous capture mode press this button again to stop Delete the selected picture video in Playback mode Increase the brightness of live view View amp playback captured still images and video files Decrease the image magnification in camera and picture playback mode Solid Red Standby Flashing Red Power on Solid Green HDMI output Solid Orange TV output Flashing Orange Search for Access Point Solid Blue Connected to Access Point Flashing B
Download Pdf Manuals
Related Search
Related Contents
JRX118SP User Guide Digitus KVM Switch 1User - 4PCs User Manual Important Safety Precautions MANUEL D`UTILISATION Ma retraite Manual de Operação e Manutenção うまい米作りの手引き Copyright © All rights reserved.
Failed to retrieve file