1. PB 2200 4200 Series Ae User s Manual Rev Original FCC Notes This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions manual may cause interference to radio communications It has been tested and found to comply with limits for a Class A digital device pursuant to subpart J of Part 15 of FCC Rules which are designed to provide reasonable protection against interference when operated in a commercial environment Operation of this equipment in a residential area is likely to cause interference in which case the user at his own expense will be required to take whatever measures to correct the interference Warranty Limits Warranty terminates automatically when any person other than the authorized technicians opens the machine The user should consult his her dealer for the problem happened Warranty voids if the user does not follow the instructions in application of this merchandise The manufacturer is by no means responsible for any damage or hazard caused by improper application About This Manual Posiflex has made every effort for the accuracy of the content in this manual However Posiflex will assume no liability for any technical inaccuracies or editorial or other errors or omissions contained herein nor for direct indirect incidental consequential or otherwise damages including without limitation loss of data or profit
2. Direct drive type Posiflex cash drawers Model numbers coded as CR 3100 CR 3200 CR 4000 or CR 4210 Programmable Keyboard Various types of Posiflex programmable keyboards Most recommended KB 6000 KB 6200 series or KB 6600 Bar Code Scanner Short range type near contact and long range type 250 mm for CD 3830 CCD scanners POS printer Posiflex 9 pin dot matrix impact printer or Posiflex thermal printer of RS232 serial interface parallel interface USB interface or even wireless interface SYSTEM BOX CONTENTS When you receive the system box you will find it contains several items e PB system unit e This user s manual e Recovery CD for preloaded OS or Posiflex Product Information CD for driver utilities without OS e Optional components installed to system unit as ordered e Main power cord 1 piece for PB 4200 only e Power adaptor with power cord 1 set for PB 2200 only Part 5 INSTALLATION GUIDES IMPORTANT Please do not connect the power cord or turn on the main unit until you have fully read the installation guides and followed the instructions TECHNICAL ENHANCEMENTS Applicable technical enhancements in PB series include serial COM port power supply settings RTC battery replacement VGA port power supply setting DRAM upgrades and adding a half length PCI adapter card in PB 4200 this item is possible only when no powered USB port option installed All these technical enhancement operations require purchase of applic
3. NO Push The electric charged device come into the Spring area of the main unit Please also note Buttons on that not to touch any component or 5 ble insid Both Sides ca a eu and Raise ease first disconnect every The Rear Part cable from the main unit and prepare enough space in front of the PB system and lay a piece of clean soft clothe of appropriate size there to of Top Cover Part 16 prevent damage With the back cable cover opened push in the circled spring button in the above picture on both sides of chassis and raise the rear edge of the top cover Apply some mild maneuver if there is already a pole display mounted Cleaning for Side Ventilation Use vacuum cleaner to remove any dust or threads accumulation away from outsides of both ventilation grids on chassis exposed after removal of the front cover as in pictures below and close back the top cover when done u Side Ventilation Grids on Chassis Part 17 Part 20
4. chassis as indicated by the hollow arrow in the right picture Front Cover Release Opening Chassis Bottom View Please then pull the bottom side of front cover forward to release the bottom hooks of front cover from the chassis as indicated by hollow arrow in left picture Part 15 Now pull the left side of front cover down a little to free it from the main cover as in the right picture It may be required to push the power switch down to completely remove the front cover Power Switch Cleaning for Front Ventilation Use vacuum cleaner to remove any dust or threads accumulation away from both the ventilation holes on front cover and ventilation grids on chassis exposed after removal of the front cover Front Ventilation Grids on Chassis Ventilation Holes on Front Cover Replacing Front Cover Follow the opposite procedure as removing the front cover to replace the front cover in position Please make sure the all hooks on front cover is well positioned into chassis Please remember to check that the power switch is at Off position before power and signal connection Accessing Side Ventilation Grids The operation to further clean the side ventilation grids requires much more highly technical maneuver Therefore careful attentions must be taken throughout the further cleaning operations below When the main unit is opened there must be no liquid spill no electro conductive material
5. integrated design it has retained many of the secure features of a traditional ECR and has avoided the wiring spaghetti associated with more traditional PC solutions This Open Standard Architecture ensures that this terminal can use the PC application software and development tools that are now inexpensively available and abundant The terminal may be used as a self content unit or as one of several terminals in a network system controlled by a back office computer through the integrated network interface Versatile options besides the basic model selection can apply to it too There are various options applicable internally including an UPS function module with cash drawer port PB 4200 only UPS battery and Pole mount VFD customer display through powered COM port CF memory card reader or powered USB ports The external options cover even much wider range including Wireless LAN Cash drawer POS printer Bar code scanner Programmable keyboard etc Part 3 THE STANDARD FEATURES CPU Celeron 2 0 GHz or P4 2 4 GHz or up for PB 4200 AMD NX1100 for PB 2200 HDD 40 GB or above for PB 4200 20 GB or above for PB 2200 RAM 256 MB upgradeable to 2 GB max for PB 4200 128 MB upgradeable to 2 GB max for PB 2200 Ethernet Networking The standard network port works with both 10 Base T and 100 Base T Serial Ports In PB 4200 system there are 4 serial ports and COM1 is shared by the direct driven cash drawer port if exists In PB 2
6. will be distinguished by the software command AC POWER for PB 4200 only The power supply or power adaptor operating voltage must be checked to support the city power supply specification This must be done WITHOUT any connection to the AC power Part 9 The power supply cable should first be connected to the power inlet but NOT the wall socket This cable should be consolidated with other cables and come out of the connection area through the bottom opening of the chassis OPERATING SYSTEM RECOVERY The operating system exists in the HDD in top of the system unit Once the software system on HDD collapses it is possible to restore the operating system onto a physically intact HDD with use of the Recovery CD that comes with the preloaded operating system Please follow the instruction from your system integrator for system software restoration Follow the instructions below for operating system recovery only if your system integrator does not advise otherwise For the PB system preloaded with Windows system on HDD Posiflex provides recovery CD delivered with the hybrid terminal for the preloaded operating system The System Integrator shall take care of software restoration after OS recovered Use a Posiflex supplied USB interface external CDROM drive for such action Other brand CDROM drive may require its specific driver different from what supported in the recovery CD Please use the recovery CD in rescue operation on
7. 200 system there are 2 serial and COMI is shared by the direct driven cash drawer port and the UPS function For both PB systems each COM port is capable of providing independently a 5 V DC or a 12 V DC supply All these DC supplies are achieved through internal jumper setting and they are all defaulted to give no DC supply at delivery Parallel Port Each PB system is equipped with a parallel port that supports SPP EPP ECP VGA Port There is a VGA connector for connection of external monitor with 12 V DC power supply potential through jumper setting change included CR Port 1 port can be used to control 1 or 2 Posiflex printer drive type cash drawers UPS function module required for PB 4202 built in for PB 2202 USB Ports The PB 4200 series is equipped with 3 USB type A connectors and the PB 2200 series is equipped with 6 USB type A connectors for connection of USB Universal Serial Bus devices Modem Ring Up LAN Or Alarm Wake Up The PB series can be turned on automatically upon an incoming COM port Modem call or LAN status or data packet received on LAN or a preset time day week month UPS function optional module for PB 4202 built in for PB 2202 The most advanced UPS functions to safeguard the POS operation against intermittent power failure with another option UPS battery careless touch on the power switch unmanned remote account consolidation operation etc battery itself is an option Accidental power off protection The p
8. able Technical Manual from Posiflex or consultation from Posiflex authorized dealers and should be handled only by a qualified technician NON USER INSTALLABLE OPTIONS When the PB system is ordered with options like expanded system memory 2 HDD CF memory card reader slot powered USB ports PB 4200 only or UPS function module PB 4200 only the option s is are already installed in the system delivered Therefore no more installation is required However please note that when the powered USB ports option is installed adding a half length PCI extension card will no longer be possible HALF LENGTH PCI EXTENSION CARD If the PB system is not installed with the powered USB ports option PB 4200 only adding a half length PCI extension card is possible However the whole operation will involve cautiously accessing the interior of the system replacing the slot window metal plate applying the card and installing its driver Therefore only a computer expert can perform this operation on his own risk MAIN CONNECTION AREA The PB series is constructed for very easy maintenance Press inward both plastic buttons at lower rear corners on both sides of the system unit circled in right Push This Button picture to release the lower part and also The One of back cable cover Please note on The Other that there are 2 plastic hooks on Side to Open top cover holding the back cable Cable Cover cover as marked on upper part of the picture Care
9. ce Attempt to recharge a dead battery is dangerous lt gt A separate battery monitor is not required for this series DAILY MAINTENANCE GUIDE For regular cleaning of the PB systems please use only soft haired brush or dry soft cloth You may use moist soft cloth to remove stains when necessary Apply only proper amount of mild neutral detergent for obstinate stains Please note that never use Acryl dissolving solvent or Polycarbonate dissolving solvent Part 2 MN BRIEF INTRODUCTION THE USER S MANUAL The purpose of this manual is to guide the user in the initial installation and general use of the Posiflex PB 2200 4200 series of POS terminals It does not explain any application software that may be supplied with it We intend to provide our customers with all technology advantages available by evolving the product design to incorporate appropriate changes and improvements So some detail differences may exist between this manual and the equipment supplied For more detailed or technical information please refer to the CD ROM disc associated or consult our authorized dealers or visit our web site http www posiflex com tw or http www posiflex com THE PRODUCT The Posiflex range of PB 2200 4200 terminals have been designed and manufactured to meet the high end demand on POS systems It incorporates all the advances of PC technology within a rugged housing designed for use in a hostile retail environment By providing an
10. ckage from the system unit Please follow the Installation Guide in package of the option The customer display will occupy one COM port or one USB port However before installing an integrated customer display option on a PB system please have a qualified electronics technician to set up power supply to the customer display in the COM port used if the pole display is of RS232 interface and to neutralize the power supply once the customer display is to be removed from that port AUDIO PORT The audio output port must be connected to either the earphone or a pair of speakers with booster or amplifier if used When the audio amplifier option is installed there will be an internal speaker inside the main unit with amplifier constructed on the internal PCI riser card PROGRAMMABLE KEYBOARD OPTION All types of Posiflex programmable keyboards can be applied in PB system Most recommended models are KB 6000 KB 6200 series and KB 6600 Just connect it to the PS 2 KB port in the main connection area The application of the keyboard requires no software driver and is free from any software compatibility issue The system integrator can program the content of the keyboard for the application software following the technical guidance of Posiflex keyboard programming utilities BARCODE SCANNER OPTION Modern barcode scanners applied in POS business are of KB interface type Most of them provide both a male and a female PS 2 KB connector Therefore i
11. ction module option is installed in PB 4200 However it is recommended that the Posiflex CR 3100 or CR 3200 or CR 4000 or CR 4100 or CR 4210 be used for best compliance The PB system will directly control the cash drawer using the cash drawer port CR both to operate the opening mechanism and to monitor the drawer open status Both functions may be accomplished under software control of the COMI serial port Use the cable supplied with the CR 3X00 4X00 cash drawer Part No CCBLA 180 for connection to the CR port in PB system This cable has a 6 pole plug at one end and an 8 pole plug at the other The 8 pole plug should be inserted into the connector marked signal cable from POS Printer at the rear of the cash drawer The 6 pole plug should be inserted in the connector marked CR found in the main connection area in the system The user may also use the optional 2 in 1 cash drawer control cable CCBLA 238 to control 2 cash drawers in 1 port It has a 6 pole plug at one end and two pole plugs at the other The 6 pole plug should be inserted in the connector marked CR found in the main connection area in the system Each 8 pole plug should be inserted into the connector marked signal cable from POS Printer at the rear of one of the cash drawers The cable lengths for the two 8 pole plugs are different Use the shorter one for the original cash drawer CR1 and use the longer one for the extended cash drawer CR2 that
12. fully release the back cable cover from the hooks to show the main connection area Note Never press the 2 springs on the metal walls as cross marked in the picture Carelessly pressing on these 2 springs could cause damages The user shall be responsible for such kind of damage Even the maintenance technician must always pay attention to always disconnect all power and cable connections before pressing the 2 springs and not to cause any damage either in the top cover opening operation after pressing the 2 springs or by leaving or spilling any improper materials inside after the opening operation POWER ADAPTOR for PB 2200 only The power connector resides in the lower left corner of main connector area Please make sure that the cable from the power adaptor is inserted into the power connector of PB system in the correct orientation as illustrated in right drawing The manufacturer is not Fr E o responsible for any damage caused by improper orientation of this connection Please check that for straight type power plug the arrow mark on the plug is at top side of the plug For right angled power plug if the arrow mark is on its end it should be pointing up If the arrow mark is on one side of the right angled power plug it should be on the right as in the drawing Please also check that the city power supply specification from the wall socket is within the operation range of the power adaptor UPS BATTERY OPTION When the PB sy
13. he beep will go rather fast when the UPS battery approaches a fully discharged condition to remind the operator that power will soon finish In few seconds the whole system will soon be automatically turned off In case the AC power resumes during the usage of the battery power the battery operation will keep on for few seconds before the AC supply is confirmed stable CUSTOMER DISPLAY The optional customer display PD 2601 or PD 7321 mounted on a pole at rear corner of PB system can be turned horizontally for best viewing effect in application FAN CONTROL In the preloaded OS for this PB system there is an embedded function that can keep on monitoring the interior temperature and the fan revolution rate and regulating each required fan power to gain maximum ventilation effect with lowest possible noise This function is disabled by default at delivery The user can decide to engage this function by clicking Start gt Programs gt Posiflex Tools gt Posiflex Fan Control to pop up a window like the right picture Click Enable then Apply to engage this function Apply Cancel in background This function will remain Fan Control Setting Enable Disable Part 14 operating even after system restart To disable this function you have to pop up this window again and click Disable then Apply and restart the system If system hang due to CPU overheat occurs please review t
14. he ventilation condition and environment temperature check if the fan is stuck by contaminants such as dry grease or threads and try to correct the situation when the system is off and cooled down You may power up the system again after the system cooled down and trouble cause removed However if the trouble remains please consult your dealer for possibly fan replacement on worn out USB There are three for PB 2200 and six for PB 4200 standard USB female connectors in the rear room All support the Universal Serial Bus Specification standard 2 0 and also 1 1 If for any reason though very unlikely in ordinary practice these ports have to be limited as USB 1 1 only please enter BIOS setup and go to Integrated Peripherals then SiS OnChip PCI Device and disable the item USB 2 0 Supports If the powered USB ports option is installed in the PB 4200 system please be sure to insert the USB device always to the exactly correct type of the connector VENTILATION MAINTENANCE To keep this equipment in orderly service following maintenance should be performed on a regular basis Removing Front Cover Please first remove any power and signal connection to this equipment Please then check at the bottom side of the chassis that there is a gap between the bottom side of front cover and the chassis at the left corner of front cover Pull the front cover out from this opening to release the left side hook of front cover from the
15. igned for the PB system when the 12 volt DC power is supported Consult your dealer if you have any doubt Note 12 volt DC power is available on pin 9 of the VGA connector and is supported by the UPS function if the UPS function module option with UPS battery is installed The video memory of this port shares from the system memory The video memory size can be set in the BIOS CMOS setting to match the user s application Serial Port COM1 If all PB 2200 and the PB 4200 installed with the UPS function module option a COMI terminator will also be supplied Please always occupy COM serial port by a suitable serial device or this terminator If this port is left vacant or connected with something like a mouse the power switch management and the cash drawer control when UPS function module option is installed may fail to work correctly An RS232 MODEM is not applicable to this port It is recommended to use COM2 3 or 4 instead in PB 4200 and use COM2 instead in PB 2200 Part 12 POWER ON OFF CONTROL The PB terminal implements electronic power control such that the main power to the system may be controlled by many methods as below 1 Hardware power switch 2 Software OFF command 3 Automatic power ON control 4 Emergency power OFF Switching from OFF to ON requires a normal supply of the AC power Hardware Power Switch This button is located at bottom front corner of right side as in right picture and can be used to turn the s
16. keep monitoring for the preset conditions and turn on the system when the preset conditions are met Please note that if the PB system is improperly turned off before a complete boot up procedure the above preset power on control functions will Part 13 be disabled until next turning off after a complete boot up Emergency Power Off In case of serious system halt due to any reason the system could fail to be powered off through normal means Press and hold the Power ON OFF Switch for Emergency Power Off Release the switch after the system powered off It will take about 4 seconds if no UPS function module installed and it takes about 10 seconds if the module installed If there appears to give a special coded beep tone in the pattern short long short long short prior to the system power off in this process please remove the AC power and wait for few minutes to allow the hardware registers to reset If there is no such beep AC removal is not required Then you may restart the system and take remedial action against the precious failure UPS Function When the UPS function module and a functioning UPS battery are installed this function can be automatically enabled if the machine is operating on the preloaded OS from the manufacturer When the external power is interrupted during system operation with the UPS function enabled the system will give periodical beep to indicate the status of system working on battery power T
17. ly Using it otherwise may wipe out whatever stored in the HDD All upgrade devices drivers needed for manual installation in usual way are available in the subfolder drivers in OS recovered HDD and the latest versions of these required drivers will be available on our web http www posiflex com or http www posiflex com tw Now please follow instructions from your system integrator for software recovery after OS recovery and driver installation OPERATING SYSTEM INSTALLATION This product is a highly professionalized equipment The installation of an OS into a machine without any preloaded OS could constitute major difficulty for average user who either has barely limited technical knowledge of this professionalized equipment or is insufficiently equipped with necessary facilities to accomplish such a task Therefore installation of an OS into a system without preloaded OS is highly discouraged Posiflex shall not be responsible for any technical support to questions arisen due to non preloaded OS Part 10 USING THE PB SYSTEM BEFORE POWER ON A Check List It is very important that you check the following operational points Ventilation This terminal must NOT be operated in an environment with restricted ventilation There must be at least 25 mm air clearance around any top or side ventilation holes with a free flow of air around the unit at ALL times for the installation Operating Environment The equipment mu
18. oaded OS for a PB series with UPS function module either by option for PB 4200 or by default for PB 2200 ttt there is a built in utility Posiflex Power Switch ET ka ws pets Manager that will indicate the UPS battery status of Fe the battery When an installed UPS battery is found CH ej O Part 11 to be disabled or when pop up warning message like this picture appears please replace the used up UPS battery at power off as soon as possible Emergency treatment The battery is constructed maintenance free and leakproof Its storage space in PB system also provides very good protection as long as the ambient temperature remains below 30 C and the ventilation of the PB system remains free However should any accident happen and the sulfuric acid from the battery spills on skin or dothing wash immediately with water If the acid comes in contact with eyes rinse eyes with large amount of clean water and see a doctor immediately A larger external battery may be connected to give an extended operation Please check your dealer about this capability when required WARNING If there are any signs of over charging or leakage of electrolyte please contact your dealer immediately VGA Display Port The VGA port in the PB terminal can support a 12 volt DC power to the external monitor through the VGA signal cable This may cause permanent damage to any other monitor not designed to use this facility Please use only a Posiflex monitor des
19. ower switch is safely located at one side and this power switch can be defined as a ON switch only through software command UPS function module required for PB 4202 built in for PB 2202 THE OPTIONAL ITEMS Note Underlined items below must be installed prior to delivery from factory Attempt to apply them by end users is either too difficult or is likely to cause damages Italic items below are stand alone peripheral devices a DRAM Memory Expansion Upgrade up to 2GB max Part 4 b c d e f g h i j D m n 0 p 2 HDD 2 5 IDE interface Compact Flash Memory Card Slot Type I Powered USB Port for PB 4200 only 2 ports for 12 V and 24V support each separately Selecting this option will deny the PCI slot extension Audio Amplifier and Internal Speaker This option can be available only in systems equipped with PCI riser card of revision C or later Customer display Pole mount 2 x 20 VFD display Wireless LAN Adaptor inside back cable cover IEEE 802 11b g Preload OS Win 2000 Win XP pro or WEPOS LCD monitor 12 1 LM 7112 without touch panel or TM 7112 with touch panel UPS Function Module with CR Port for PB 4200 series only UPS Battery 2 3 AH 12V lead acid maintenance free battery 2 in 1 Cash Drawer Control Cable Cable CCBLA 238 when added to the optional CR port of the PB series can be used to control two Posiflex printer drive type cash drawers Cash drawer Printer
20. s P N 14420900010 Part 1 ALERT TO OUR HONORABLE CUSTOMERS Please always read thoroughly all the instructions and documents delivered with the product before you do anything about it Don t take any premature action before you have a full understanding of the consequences This product contains inside a Lithium battery and maybe also a sealed type Lead acid battery if the UPS battery option is ordered Please always follow local environmental protection laws regulations for disposal of used batteries and always replace only with battery of same type O If you have an UPS battery installed in the product lt gt Temperature above 40 C must be strictly avoided as it could cause termination of battery life and unexpected result even if the battery is not in work lt gt Do not power off the system just by shutting off the AC power leaving the battery supporting the whole system till completely exhausted Repeatedly using it up or improper maintenance reduces the battery life dramatically lt gt Always fully recharge the battery at least once every 3 months if the battery is not connected Always disconnect the UPS battery from the system if the system is to be left OFF for more than 72 hours to prevent possible damage Only connect the UPS battery back right before you are going to re power on the system lt gt Replace the battery as soon as the monitoring software indicates the battery is out of servi
21. s resulting from the furnishing performance or use of this material This information is provided as is and Posiflex Inc expressly disclaims any warranties expressed implied or statutory including without limitation implied warranties of merchantability or fitness for particular purpose good title and against infringement The information in this manual contains only essential hardware concerns for general user and is subject to change without notice Posiflex reserves the right to alter product designs layouts or drivers without notification The system integrator shall provide applicative notices and arrangement for special options utilizing this product The user may find the most up to date information of the hardware from web sites http www posiflex com or http www posiflex com tw All data should be backed up prior to the installation of any drive unit or storage peripheral Posiflex will not be responsible for any loss of data resulting from the use disuse or misuse of this or any other Posiflex product All rights are strictly reserved No part of this documentation may be reproduced stored in a retrieval system or transmitted in any form or by any means electronic mechanical photocopying or otherwise without prior express written consent from Posiflex Inc the publisher of this documentation O Copyright Posiflex Inc 2005 All brand and product names and trademarks are the property of their respective holder
22. st not site in direct sunshine near a heater or in a damp and must be free from contaminants like dust smoke or fume The equipment must not be operated or stored in extremes of both temperature and humidity moisture Operating range PC to 35 C and up to 80 relative humidity non condensing max wet bulb 26 C Power Supply The operating voltage of the power supply should be checked to confirm that it is set within the range of the local power supply The power cable the power outlet and any power fusing arrangements must conform to local safety regulations UPS Battery option General care The UPS battery is consumable beyond product warranty Please definitely observe the alerts in beginning of this manual If the equipment is to be powered off for more than few days please always disconnect the battery from the system Reconnect it and turn on the system to recharge the battery for 1 2 hours every 3 months for temperature lower than 30 C Recharge for 1 2 hours every month for temperature over 30 C Temperature above 40 C must be strictly avoided as it could cause termination of battery life and unexpected result even if the battery is not in work The UPS battery can support basically the data preservation and smooth running of the system during intermittent or few minutes 2 6 min depending on loading and battery condition power failure if the UPS function module option is installed Battery replacement In the prel
23. stem is installed with the UPS battery with also an option of UPS function module the UPS battery is in the carton at delivery Please take it out and place it in the battery compartment at center upper part of the connection area indicated as upper rectangle in picture at right Connect the cable to its connector in the main connection area UPS Battery Compartment UPS Battery Connector beneath the battery compartment in PB 4200 PB 4200 or beside the power connector in PB 2200 only when the system is about to power up UPS Battery Compartment for operation Always disconnect the UPS battery when the system is to be left powered off for more than few days Please pay particular attention to the environment requirement for UPS battery in next chapter USING THE PB SYSTEM UPS Battery Connector PB 2200 Part 7 WIRELESS LAN OPTION When the wireless LAN option is ordered with the PB system this option is already installed in the delivery inside the back cable cover with its cable connected to one of the USB port This cable must be disconnected first if installed whenever the back cable cover is opened for any operation CUSTOMER DISPLAY OPTION When the PB series is ordered with the customer display option the customer display together with the pole for installing them to corner of back cable cover will be delivered in separate pa
24. t can be connected either to the bottom of the Posiflex programmable keyboard with the cable fit into the strain relief groove or in between the PS 2 KB port of the system unit and the Posiflex programmable keyboard The only consideration is that in programming stage of the programmable keyboard nothing including the barcode scanner should come in between the system and the programmable keyboard However this should be no problem in application phase When a KB interface barcode scanner is installed in PB series a Part 8 connection of a normal PS 2 keyboard or the Posiflex programmable keyboard could become obligatory by some OS Therefore if there will be no keyboard installed for such OS it is advisory to use an USB interface type barcode scanner instead of the PS 2 KB interface type PRINTER OPTION There are many models of Posiflex POS printers that can be applied in PB system These printers cover several interface technologies Please connect the printer to a COM port the LPT port or an USB port in the main connection area depending on the printer model and then connect its power adaptor It is also possible to control a Posiflex wireless POS printer by connecting a separately purchased wireless Dongle to one of the COM ports in PB system CASH DRAWER OPTION The RJ11 connector in main connection area of a PB system can be used for controlling most of the common cash drawers available on the market only if the UPS fun
25. ystem on and off alternatively if no UPS function module installed When this function module is installed this hardware switch can also be programmed to be an ON only switch through software command so that when this switch is accidentally pressed during system turned on the system just remains on and unaffected Software Off Command The system may also be shut down under software control if the UPS function module is installed Please just follow the arrangement by your system integrator for this capability Automatic Power On Control The system may also turn on according to some preset conditions such as Modem Ring Up and Alarm Clock Wake Up or LAN Wake Up To utilize Modem Ring Up or Alarm Clock Wake Up function the user should enter the CMOS setup by pressing Del key at system boot up choose for PM Wake Up Events in Power Management Setup and make the Ring Power Up Control enabled for Modem Ring Up or select the Power Up by Alarm for Alarm Clock Wake Up Save the configuration and exit the CMOS setup program The Preset Power On Control will then be ready after a normal power off For LAN wakeup an operating caller system connected through LAN to the system is required It also requires a qualified networking technician to check the LAN chip ID of the PB system for the caller system to wake it up When the PB system is turned off after a successful boot up the preset automatic power on functions will