Home
Line Seiki
Contents
1. this device near machines that emit strong electromagnetic fields or objects that store static electricity Do not drop or subject this device to strong impact Do not use or store this device where it will be exposed to water or in places with wet conditions Do not use or store this device where it can be exposed to high temperature and high humidity See the battery case markings to ensure that the batteries are properly installed Do not attempt to disassemble or modify this device When using the device via USB power avoid excessive movement to ensure that the device will not be disconnected and power will not be lost The unit is shipped with protective seal on the display This manual was last revised May 13 2015 4DK5003A Contents are subject to change even without prior notice All Rights Reserved Copyright 2015 LINE SEIKI CO LTD
2. DK 3000 SERIES MANUAL INSTRUCTION MANUAL DK 3005C Thank you for purchasing our product DK 5005C Please confirm that you have the correct device by checking the product label Please read this instruction manual carefully before using this device to ensure correct usage Please keep this instruction manual for future reference E INTRODUCTION DK 5005C is an electronic tally device which logs the count values of five 5 count keys and the total count at a preset log interval Logs are saved with a corresponding timestamp and a collection of logs stored is called a Record It has a built in calendar clock for timestamp X Important This device requires DK 5000 Mieruzzo Software to view Record details The software runs on Windows 7 8 or 8 1 OS Please use a micro B to A USB cable to connect the DK 5005C device to a computer The companion software enables user to download delete and save data from the device toa computer The software also enables real time display of the device on a computer Mi POWER SUPPLY The device can be powered through three power supply options The list below shows the power supply options according to priority of usage gt 5 5mm DC Jack 9V 50mA X gt USB Power 5V 100mA gt 4pcs AAA Battery X Please use Line Seiki AC DC Power Adapter for DK 5000 sold separately to power the device via DC jack Upon initial connection to a power supply or resumption of power the device will pe
3. Holding down SUB and also holding down these keys will continuously decrement the values being edited Note While SUB is held down the SUB icon will appear on the upper right corner of the display MEMORY CAPACITY The device memory can save up to 250 records which is achieved when only a maximum of 192 logs are made per record through the log interval MEM A memory low indicator 1 will be blinking twice every 5 seconds when the size of memory used is 80 or more MEM Fi A memory full indicator will be blinking when 100 of memory is used po LL X Important When memory is full starting a new Record will erase the oldest Record to free up memory space for the new Record created Location of Records will shift and Memory No will change accordingly When memory is full and device is in Count Mode saving a new log that requires additional memory space will erase the oldest Record to free up memory space While erasing a Record the device will show a Record Data to Clear message and logging of count key press is temporarily disabled W SPECIFICATIONS Display 4 Digit 0 9999 Internal 5 Digit 0 99999 6 Digit 0 999999 0 C 50 C non freezing 35 85 RH non condensing 10 C 60 C non freezing 70 H x 170 W x 25 D mm Approx 130g accessories not included CE RoHS For more details please visit our website at http www lineseiki com N ATTENTION Operation Do not use
4. This is the default operation mode Standby Mode is indicated by the displayed text Standby The TIME icon and the current time is also shown on the upper left side of the display Logging of count key press is disabled in this mode By pressing the corresponding key combination of F with 1 2 3 or 4 other operation modes can be accessed from Standby Mode By holding down Count Mode can be enabled See KEY OPERATION for details Count Mode Count Mode is indicated by the displayed count values for each count key and the total count The QTIME icon and the current time is also shown on the upper left side of the display Coo 1004 Count key presses are recognized in this mode and interval logging is enabled The individual count values and the total count value are updated with every press of corresponding count key By pressing the corresponding key combination of F with 1 2 3 or 4 other operation modes can be accessed from Count Mode By holding down Standby Mode can be enabled See KEY OPERATION for details Setting Mode There are three Setting Modes a Date amp Time Setting b Device ID Setting c Log Interval Setting When accessed from Standby Mode Date amp Time Device ID and Log Interval can be viewed and edited respectively When accessed from Count Mode editing is disabled See KEY OPERATION for details Memory Recall Mode This mode enables viewing of all saved Rec
5. de and logging is enabled The display will show 0 count value 1 The Record will be a collection of data logs composed of count values and corresponding Timestamp Data logs will be saved in the Record periodically at a preset log interval While in Count Mode hold down for 1 second again to end recording of data The Record will be terminated and saved with corresponding count values and End Timestamp 2 The Memory No indicated by MEM will increment by 1 everytime a new Record is saved 3 While saving the display will blink twice showing the Memory No and corresponding Timestamp then the count values saved KEY 2001 4 After saving the device will enter Standby Mode and data recording is disabled Note The Record End Timestamp will be used to identify Records in Memory Recall Mode and as Record Name when data is downloaded on the companion software COUNT KEYS Count Mode While in Count Mode press 1 2 3 4 or 5 to increment the count values of corresponding count keys Note Make sure to push the count keys properly to avoid missed count or SUB KEY Count Mode Hold down SUB and press 1 2 3 4 or 5 to decrement the count values of corresponding count keys Setting Mode Hold down SUB and press 1 2 3 4 or 5 to decrement values being edited such as Year Month Day Hour Minute or Device ID digit values
6. e e sync device time to computer system time e change Device ID The software also has an Acquire Present function which enables the current count values on the device to be displayed on the computer Please refer to the DK 5000 Mieruzzo Software User Manual for more details When the device is connected to the software the icon will appear on the upper right corner of its display E LABELS D o o BALAB ii A One Boot a Mo OOD OOOD ggaBag 99 Clock Memory No Display Key 2 Count Display 0 Count Key 3 Date Time Icon 1 Subtract Key Subtract Icon Strap Hole Battery Warning Icon Function Key Software Link Icon USB 2 0 Port 5 5 mm DC Jack 5 Total Count Display 8 Power Key Mi KEY OPERATION POWER KEY Power On Off To switch ON hold down POWER for 1 second The default power up display is Standby Mode showing the text Standby on the display To switch OFF hold down POWER for 3 seconds When switching off from Count Mode the Record will be ended and saved before switching off F KEY Date amp Time Setting Hold down F and press 1 to enter the Date amp Time Setting Mode The display will show the Date and Time value in the format below YYYY MM DD hh mm The Year Month Day Hour or Minute values can be incremented by pressing 1 2 3 4 or 5 Holding down 1 2 3 4 or 5 will continuously increment the
7. e no data will be displayed While clearing the memory device will show All Data to Clear Press 5 to select No No Record will be deleted and the device will return to Memory Recall Mode Press F to leave Memory All Clear Mode Note Memory All Clear Mode is disabled when Count Mode is active Make sure to keep the device powered while clearing memory or deleting Records to avoid risk of data corruption Log Interval Setting Mode Hold down F and press 4 to enter the Log Interval Setting Mode The display will show the interval logging options Press 1 to select Reset Logging Type With this Logging Type count values will be reset to 0 after saving a data log Press 2 to select Continuous Logging Type With this Logging Type count values will not be reset to 0 after saving a data log Press 4 or 5 to increment the Hour or Minute value of the Log Interval respectively Holding down 4 or 5 will continuously increment the Hour or Minute value respectively Press F to leave Log Interval Setting Mode Note x The default settings are Logging Type is set to Continuous and Log Interval is set to 00 15 hh mm Editing of log interval settings are disabled when accessed from Count Mode Start End Record While in Standby Mode hold down for 1 second to start recording of data A Record will be created with corresponding Start Timestamp The device will enter Count Mo
8. ords on the device memory Memory Recall Mode is indicated by MEM icon and the 4 digit Memory No shown on the upper left side of the display Please note that misuse of this device may lead to injury to the user or damage to the device Please observe all safety precautions and warnings in ATTENTION this instruction manual Customer Service CD LINE SEIKI CO LTD Head Office 37 7 Chuo cho 2 Chome Meguro ku Tokyo JAPAN 152 0001 Contact TEL 03 3716 5151 FAX 03 3710 4552 E mail webtrade line co jp URL http www lineseiki com Memory No represents the memory location of the Record displayed When a Record is deleted the memory location of each Record shifts and Memory No is changed accordingly There are two display modes available for viewing stored Records a Timestamp Display b Count Value Display Timestamp Display mode will show the date and time when the Record is saved Count Value Display mode will show the individual count values and the total count Memory Recall Mode also provides an option to clear all Records saved in the device memory See KEY OPERATION for details WE SOFTWARE This device works with DK 5000 Mieruzzo Software The software is downloadable for free from the Line Seiki website The software enables the user with the following functions e download the data from the device e export the downloaded data to a XLS or CSV file e delete records stored in the devic
9. rform the start up routine blinking all LCD segments for 2 7 seconds After the start up routine the device will proceed to Date amp Time Setting Mode to set the device Date amp Time See KEY OPERATION for details X Important Calendar clock will not update when there is no power supply available Make sure that there are batteries installed before disconnecting both DC jack and USB power supply to maintain calendar clock function When DC jack or USB power is connected power is not supplied from the batteries and battery charge will not be drained When operating only on batteries Alkaline type batteries can provide at least up to 200 hours of Operation under normal operating condition CG icon will appear on the upper right corner of the display to indicate a low battery condition C4 icon will blink continuously under following conditions gt when battery is almost empty gt when no battery is installed while the device is powered by DC jack and or USB If all power supplies are removed the last device Date amp Time will be stored in a temporary memory If device is in Recording Mode Record will be saved When the device is powered ON again it will resume operation in Date amp Time Setting Mode using the last saved Date amp Time values See KEY OPERATION for details WE OPERATION MODES This device has four main operation modes namely Standby Mode Count Mode Setting Mode Memory Recall Mode Standby Mode
10. se values respectively Press F to leave the Date amp Time Setting Mode Note Editing of Date amp Time is disabled when accessed from Count Mode F KEY KEY Device ID Setting Hold down F and press 2 to enter the Device ID Setting Mode The display will show the Device ID a 3 digit user programmable number which is used to identify different DK 5000 devices Each digit of the Device ID can be incremented by pressing 3 4 or 5 Holding down 3 4 or 5 will continuously increment each digit Press F to leave the Device ID Setting Mode Note Editing of Device ID is disabled when accessed from Count Mode or when there is an active connection to the companion software Memory Recall Hold down F and press 3 to enter Memory Recall Mode The display will show the Memory No and Timestamp of the newest Record saved If there is no Record available the display will show no data Press 1 to display the next Record Press 2 to display the previous Record Press 3 to toggle Timestamp Display mode Press 4 to toggle Count Value Display mode Press 5 to enter Memory All Clear Mode Press F to leave the Memory Recall Mode Memory All Clear When in Memory All Clear Mode the display will show the All Clear options Hold down 4 for 1 second to select Yes All Records will be deleted and device will return to Memory Recall Mod
Download Pdf Manuals
Related Search
Related Contents
SuperReport Pro User Manual - e-Node CardioPerfect™ Resting ECG Quick Start Guide Basic "取扱説明書" Sony VGN-AX570G Security Features Guide ー圓取扱説明書 nt 9010 - Alarms BC LATEX source from word processors Setting up the butts Operating Instructions Vertical T-BoxRelay User`s Manual Copyright © All rights reserved.
Failed to retrieve file