1. solar mom m m SC 10 MPPT User Manual ELECTRICAL SPECIFICATIONS Flooded 14 5V 29V Sealed 14 2V 28 4V Peak 250W Output Power constant 200W 229V constant 150W 14 5V 0 04A Important Use only PV systems with open circuit voltage below 55V amp a minimum Vwe of 17V for 12V and 34V for 24V Charging Use wires suitable for at least 15A but if wire runs are over 3m then larger wires are recommended to limit voltage drop and losses Install the unit in a dry place out of direct sunlight and away from flammable liquids or gases Battery fuse BF is always required and must be located as close to the battery as possible its sizing depends on the wire size and load ratings Typically a 15A 24V fuse would do OPT solar Before connecting battery always check battery and PV panel polarity When used with panels over 150W 12V or 200W 24V the SC 10 MPPT MUST be fitted with the PVF fuse Locate this fuse as close as possible to the MPPT A 10A 60V fuse is recommended For optimal power output the following panel combinations are recommended 12V Charging 2 x 12V Battery Panels connected in series Total Voc 242V amp Vmr 32V 1 x 24V Battery Panel Total Voc 242V amp Vmr 32V 1x48 Cell Grid Panel Total Voc 28V amp Vue 23V 1x 54 Cell Grid Panel Total Voc 32V amp 26V 1 x 52 Cell Grid Panel Total Voc 31V amp Vue 25V 1 x 60 Cell Grid Panel Total Voc
2. 36V amp Vmr 29V 1 x 72 Cell Grid Panel Total Voc 244V amp Vue 36V 24V Charging 1 x 72 Cell Grid Panel Total Voc 44V amp Vue 36V Note This unit can be directly power without a battery a 12VDC motor or pump of up to 100W General Information Green LED flashing battery charging and all normal Red LED flashing battery voltage low below 0 9 of nominal voltage This MPPT is designed to auto detect 12V and 24V battery systems and select a suitable charge regime The absorption phase is entered following a low battery condition and is maintained for approx 1 5 hours This MPPT has a built in multilevel over temperature protection to improve product reliability while maximising output power availability The SC 10 MPPT will efficiently charge 12V batteries from 24V panels The panel voltage limits for the SC 10 MPPT are Maximum open circuit voltage below 55V Minimum Maximum Power Point at the maximum operating temperature must be above 17V for 12V batteries and 34V for 24V batteries to ensure full power If used this fuse is optional locate the output fuse OF as close to the MPPT as possible 15A 24VDC rating Settings And Configurations The SC 10 MPPT factory default setting is for sealed lead acid batteries Maximum charge voltage 14 2V and float voltage 13 4V and auxiliary switch Load configured in Low Voltage Disconnect mode The various operating modes can be configured with a combination
3. of the REN and Load R C of the front plastic cover and the switches of the rear plastic cover Always insure that the switch is set for the correct battery type The REN and Load R C are either left unconnected Insure they are insulated from any other point or grounded shorted to the PV amp bat 1 All Night DDS 2 LVD 3 6 Hour DDS 4 Vented Batteries 5 Flooded Batteries 2 8 mm mms REN Grounded Enable Remote Load Control amp Disable DDS amp LVD Floating Disable RLC amp Enable DDS amp LVD Load R C Grounded Load Disconnected Floating Load Connected Note If the REN is floating the Load R C has no effect Basic Wiring With Permanent Load Connection Note First start up may take up to one minute PY Panel EEH EEE HH Rear View Charger 000000 BF Battery Vented Battery Wiring With Dawn To Dusk Switch DDS The DDS option is intended to power loads during darkness only This feature will not trigger during short periods of low light The maximum DDS load current is 10A continuous or 20A transients The DDS can be set to 6 hours or all night 3 8 OPTI Sc ar mou mm mms PV Panel TITITILLLLLLLI 6666060 5 SSeS eee tpi 8 Hour DDS Set Up Rear view Of Charger gno PES ERE EE DDS Lo BAT AA MPPT D Ag i Hour DOS Set Up Vented Battery L L ID LIC LI Battery L
4. remote load connection and disconnection via the REN Load R C When the Load R C is grounded the load is disconnected otherwise the load is connected To configure this mode the REN must be grounded This option overrides the LVD or DDS function but has the same load limitations of 10A continuous or 20 transient 1 NN Please ensure that your MPPT has been correctly configured DDS amp BAT settings for your application Refer to the Settings and Configurations section for more information 6 8 solar mou mme m ms MPPT FAQs Q What is an MPPT MPPT stands for Maximum Power Point Tracker and is a specialised converter designed to maintain the PV voltage at the level in which it delivers maximum power to the load or battery The nominal panel output power can only be ensured with the use of an MPPT Q What are the GSL MPPTs advantages compared to standard solar regulators 1 Suitable for new lower cost high efficiency grid type panels since the MPPT can efficiently charge the batteries from relatively high voltage say 12V batteries from 36V MPP panels 2 Less interference and more accurate voltages during absorption and float What output can expect from a 150W or 200W MPPT 1 The maximum bulk charge current with a 12V battery and 150W panel is approximately 12A so you can expect about 40AH per day which is a 40W load for about 10 hours 2 The maximum bulk charge curren
5. OAD DOSE 6 Aour 005 Se1 Up Sealed PV Panel All Might DDS Set Up Rear View CH Charger AI Night ODS Set Up Sealed Baltery Wiring With Low Voltage Disconnect LVDO L The LVD option disconnects the load when the battery voltage drops below 0 85 of nominal voltage to protect the battery from damage The load reconnects when the battery voltage exceeds 0 9 of nominal voltage This feature will not trigger during short transients LVD load is 10A continuous or 20 transient 4 8 OPTI Solar PV Panel Wiring With Critical And Non Critical Loads Critical loads are generally light loads which are powered under any condition Non critical loads are loads which can be disconnected to ensure maximum on time for critical loads as well as to extend the life expectancy and reliability of the system The non critical load can be set up as LVD DDS 6 hours or DDS all night with the same DDS configuration detailed earlier PY Panel Load gy 7 Critical Load 5 8 OPT Solar Wiring The Remote Alarm The remote alarm is a normally low 5V digital signal that goes high when the battery voltage drops below 0 9 of nominal voltage the LVD disconnects or over temperature trips It has a 5mA source capability and can be used to remotely monitor system status CONI P5 or P6 Buzzer LED CON P3 us Wiring With Load Remote Control This option enables the
6. d its designed to comply with local and international EMI standards however some interference is still possible If interference occurs first try and reorient the aerial or move the sensitive equipment away from the MPPT wires Ensure the MPPT chassis is grounded Grounding a battery terminal may also help and finally you can try adding ferrite clamps 7 8 mor nem PE a MECHANICAL SPECIFICATIONS Drawing amp Dimensions oO D o 8 IBLERANLE mmt Lmcn It z UNIT meLieich Connector Types amp Pin Assignments Connctor Connector Type Pin Signal Number Number Pin 1 Pin 2 LOAD DINKLE EHK381V or Equivalent Pin 3 Pin 4 BAT Pin 5 Pin 6 PV amp BAT Pin 7 Pin 8 PV JST S 3B PH K S or Equivalent Remote Alarm Load Remote Control Mating Connector JST PHR 3 or Equivalent REN 8 8
7. t with a 24V battery and a 200W panel is about 8A so you can expect about 30AH which is a 40W load for about 15 hours Q Why are MPPT used mainly in high power systems Until now and despite their overwhelming advantages MPPTs have been excluded from low power systems because of cost The new MPPT specifically designed for low power makes economic sense even in small systems What sort of batteries should 1 use 1 A deep cycle battery is a must due to the cyclical nature of solar systems with a recommended battery capacity of at least 60AH 2 A larger battery will not only give longer run time during low light but also will be able to avoid available PV power being unstored such as when the battery reaches the float stage Q How does PV temperatures affects charge current Temperature increase brings down the PVs maximum power point voltage reducing the MPPTs current gain available In principle at 25C it is possible to achieve 3096 gain but at 40C A more realistic average temperature about 20 is still available Q What happens at low PV currents The MPPT will outperform the conventional regulator above 496 of nominal panel power Below 496 6W in a 150W panel the MPPT will have a slightly lower output current than a non MPPT Q Is interference possible and If so what do I do MPPTs produce far less interference than conventional solar regulator during the absorption and float stages that is during most of its operating time an