1. places without protection 3 Maintenance 3 1 Hydraulic Oil The oil mass shall be checked every month It is recommended to use 32 hydraulic oil GB11118 89 Its kinematical viscosity is 32cSt at 40 and the total quantity is about 1 3 liters The hydraulic oil shall be changed every 12 months 3 2 Daily Check The daily check can effectively find faults and defects Please check the following before operation 1 Check the stacker for scrape bend distortion and crack 2 Check the oil tank for oil leakage 3 Check whether the voltage of the storage battery is normal 4 Check whether the wheels are flexible 5 Check whether the brake is safe and reliable 6 Check whether all the screws and nuts are tight Warning Be sure not to use the stacker if there is any fault or defect 3 3 Lubrication Lubricant oil shall be injected to each lubricating point each month Lubricating points 1 Mandrels and bearings of the wheels Lubricating oil 2 Connecting pins and shafts Lubricating oil 3 Rollers and shafts Lubricating oil 4 Chains and chain wheels Lubricating oil 5 Oil nipple Lubricating oil 3 4 Operation 4 1 How to Use the Brake Note When the stacker does not move please brake to avoid accidents The brake is installed on the left side of the steering wheel 1 Press the brake pedal to brake 2 Lift the brake pedal to release 4 2 Fork Lift Fall 1 Avoid overloading and
2. try to use the stacker within the rated load 2 The load should be at least distributed onto 80 percent of the platform area It is forbidden to place a load on either side or on the front edge of the platform When the forks of the stacker are used to transport and stack pallets please dismount the panel on the forks 3 Turn the emergency start button onthe control platform clockwise connect the power supply and operate the lift button in the centre of the control platform and the forks will rise release the button and the forks will immediately stop rising press the fall button and the forks will fall and release the button the forks will immediately stop falling Warning Never put any part of the body below the panel and the forks 5 Charging of Storage Battery 5 1 When the voltage of the storage battery is lower than 10V the battery shall be charged 5 2 This stacker uses the maintenance free storage battery which does not involve adding water until the service life of the storage battery ends in the normal condition 5 3 The ambient environment shall be dry well ventilated and 4 away from sparks during the charging 5 4 To charge please pull out the charger plug on the left side of the stacker insert the plug into the socket with the specified voltage and pull out the charger plug after the full charge indicator light on the panel goes on 5 5 The storage battery shall be charged once each week when the s
3. use this stacker on slopes or oblique surfaces 2 5 This stacker shall never be used to carry personnel to avoid injuries because of fall 2 6 It is strictly forbidden to touch the part of the roller operation area on the handle when the goods are lifted 2 Never put the feet in front of the steering wheel to avoid injuries caused by the falling object 2 8 Irrelevant personnel shall be at least 6 m away from the stacker when the stacker lifts or transports goods Personnel shall be strictly forbidden to stand below the fork 2 9 The goods weight shall be evenly distributed on both forks whenever possible It is prohibited to load only one fork or place the center of gravity of the goods beyond both forks 2 10 Please dont move the stacker when it rises After loading goods please lower the forks to a lower position before moving to avoid injuries caused by falling objects 2 11 Overload shall be avoided 2 12 It is strongly recommended to check the battery power before use Please immediately recharge the battery in the case of low power During the charging the ambient environment shall be dry well ventilated and away from Sparks 2 13 The stacker shall be protected from rain and water Please put it in a dry place after use and lower the forks to the lowest position 2 14 Repair and maintenance shall be carried out in accordance with the service manual 2 2 15 Operators shall use the stacker carefully in other special
4. 12V
5. Operating Manual EPS04 SMS 001_EN EPS04 Series Power Platform Stackers Note Please be sure to read and understand this manual and all warning labels on the power stacker before using It Welcome to use our EPS Series Power Platform Stackers Made of special purpose profiles our stackers feature aesthetic exterior design durability and simple operation For your safety and correct operation please be sure to understand this manual and all warning marks on the Stackers Note All the parameters here are as of the publishing date of this manual We reserve the right to change our products without a prior notice For the latest product parameters please contact us 1 Technical Parameters Lift height mm 1200 1500 Fork dimension 650 110 650 110 ee m s Lowest Fork Height LowestForkHeight mm 985 seo Gy s Speed Fulllosd mms 0 w Fal pete speed Full load Storage battery DC12V DC12V 60AH e Pump station motor DC12V DC12V 700W foe 2 Safety Instructions 2 1 Before using the platform stacker the operator must read and understand this manual and all warning signs on the stacker to prevent personal injuries or damage caused by improper operation 2 2 No untrained or unauthorised personnel should be allowed to operate this platform stacker 1 2 3 Please examine this stacker before use in particular the status of the wheels the brake the rollers and the storage battery 2 4 Do not
6. higher position for an Inject hydraulic oil Inject hydraulic oil Replace the hydraulic oil Turn the emergency button clockwise Charging the battery Fasten the wiring terminal Replace the parts Replace the large piston rod or the oil tank body Please lower the forks to the lowest position when you do not use the crane and make sure to lubricate the piston rod in time extended period of time Replace the release The release valve of the valve of the pump hydraulic pump station is station worn or damaged and thus can t be opened 5 Oil leakage Sealing parts are aged or Replace the parts damaged Replace the parts Some parts are broken The relief valve is unable to Replace the hydraulic Forks lower itself be shut tightly due to impure oil hydraulic oil Sealing parts are aged or Replace the parts damaged Replace the parts Release valve is damaged 7 Storage battery Storage battery is damaged Replace the parts can t be charged Charging plug gets loose Insert it tightly Note It is strictly forbidden to repair the stacker without authorization or training 8 Schematic Diagrams of Electric and Hydraulic System 8 1 Electric Schematic Diagram FUl Element Number Element Name u Storage battery FUO Fuse Motor Emergency stop switch Voltmeter 8 2 Schematic Diagram of Hydraulic System G1 4 0 7KW
7. tacker is out of use for a long time and each charging shall last at least two hours 5 6 The voltage displayed on the indicating gage shall be lower than 16V during the charging 5 7 It is strictly prohibited to use the stacker during the charging 6 Control Platform Emergency Button Up Button Voltmeter Down button 6 1 Emergency Button When you press down this button the power supply of the pump station motor will be disconnected when you turn it clockwise again the power supply of the motor will be connected again 6 2 Voltmeter This meter displays the voltage of the storage battery 5 When the displayed voltage is below 10V the storage battery must be charged 6 3 Up Down Buttons These buttons are used to control the rise or fall of the forks 7 Troubleshooting Fault Cause Countermeasures The reach can t the forks maximum height The forks can t be raised Pump station motor can t run The forks can not Low hydraulic oil level No hydraulic oil Hydraulic oil is impure Emergency button is not switched on Low voltage of the storage battery Wiring terminal of the power line gets loose Motor contactor is damaged Uneven center of gravity of goods or overloading causes deformation of the large piston rod or the oil tank body The forks are rusted and hard long term exposure to air to move due to when the platform stays in the