image

Contents

1. ILLUMINATION LEVEL THRESHOLD Perform steps 1 4 from the previous table section 1 choose the operation mode 1 Press and enter the gt menu 2 scrolling find F PA lt gt mode 3 Press and while keeping gt lt gt Set the value in the button pressed set the range required value then blinking dot 0 175 blinking dot release the button when the setting is done 4 Press calibration of the lt gt illumination level pr NOT RECOMMENDED TO MAKE ANY CHANGES ON THIS STEP This function allows to perform precise calibration of the illumunation level It it is really necessary to calibrate the illumination level turn the Luxmeter ON and expose to equally lightened surface or wall Make sure that there are no undesired shadows on it Then set the the values shown on Luxmeter into the RN 16TM according to the point 3 of section 5 6 VIEW OF THE PREPROGRAMMED TIME SCHEDULE Perform steps 1 4 from the previous table section 1 choose the operation mode 12 1 Press and enter the menu 2 By scrolling find SCAN 4 mode SCAN 3 Press and enter the CLOC Automatic view of the parameters menu followed by exit to the initial indication g 5 5 m 9 Action 5 Indication 5 Action Indication o m m 7 CHANGING THE SET OF PARAMETERS 1 Press and enter the menu 2 Press 3 By scrolling find SE
2. Save and Exit Select LOWER voltage threshold Press and while keeping button pressed set the required lower voltage threshold then release the button when the setting is done blinking dot 4 Set lower voltage threshold value in the range 150 210 blinking dot Press and save the selected value in the device memory Save and Exit 4 Press calibration of the present voltage RECOMMENDED TO MAKE ANY CHANGES ON NOT THIS STEP This function allows to perform precise calibration to the curtain power supply circuit If there is strong requirement it s possible to change calibration voltage when having voltmeter connected in parallel and setting the value shown on the voltmeter 9 Press and while keeping button pressed set the required value then release the button when the setting is done blinking dot lt gt Set the voltage shown on voltmeter 1 1 10 Press and save the 2 selected value in the device memory Save and Exit 2 5 5 Action 5 Indication 5 Action Indication o m a ATTENTION The turn ON OFF delay time values are set in tenths of second i e value 10 to the right from dot mean one second and etc 11 Select dH 10 item 4 turn OFF time delay in case overvoltage detected blinking dot 12 P
3. 1 4 item in the menu 4 Press and while keeping gt lt gt Press 5 times to 2 button pressed set the change the value required value then blinking dot blinking dot release the button when the setting is done 5 Press and Exit the menu 4 8 TO DELETE CURRENT SET OF ADJUSTMENTS 1 Perform steps 1 2 of the L 1 section 7 2 Press and while keeping Press 5 times to button pressed delete Ed delete all settings the settings then blinking dot release the button 3 Press and Exit the menu 4 JH E BIE ATTENTION While making changes in time schedule the numeration of the settings doesn t change so when viewing them on the display there will be shown all settings made those that are valid and the deleted not active events settings also To set the time schedule for the RN 16TM it s recommended to prepare first such a table and then to preprogamm the device Tum ON Turn ON comments Turn OFF No No Turn OFF comments Event Ne 2 198 5 WIRING DIAGRAMMS VARIANT A IF THE POWER LOAD IS LESS THEN 16A 3 5 KW THE RELAY MAY OPERATE WITH THE LOAD DIRECTLY VARIANT B IF THE POWER LOAD IS MORE THEN 164A 3 5 KW THE RELAY MUST OPERATE WITH THE POWER LOAD USING THE ADDITIONAL MAGNETIC CONTACTOR THAT WILL COMMUTATE ANY REQUIRED POWER LOAD 1 RN 18TM ro 3 4 2 3 NOTES TERMIN
4. 5 minutes Il Mode U present voltage level correct to the nearest tenth 221 5 Volts Ill Mode letter F space illumination level IF 35 illumination level 35 IV Mode HU time and voltage values are shown one after another divided by dashed line heas gnus V Mode FU illumination level and voltage level are shown one after another divided by dashed line F35 FE Ras E The User may create 2 different independent sets of parameters SP1 SP2 and may delete any of these sets if necessary Thus the client may save in the device memory 2 different settings for curtain cases Output terminals of the RN 16TM may commutate the power load up to 3 5 kW 164 If total power load connected to the RN 16TM is more than 3 5 kW 164 then it will be necessary to commutate the required power load with a use of appropriate contactor 3 magnetic starter The RN 16TM should operate with the magnetic coil of contactor and thus the required power load will be turned ON OF Please kindly note that the contactor is not a part supplied along with the RN 16TM 1 1 2 2 117 ff i ON Para 2 LO ee Ii 1 1 6 a I IIUI ES 4 gt 4 RN 16Tm m 16A fa 9 4 Li 5 p 52 A 1 green LED indicates the ON state of relay 2 green red LED signal indicates the input voltage presence 3 light sens
5. ALS 3 AND 4 MAY BE USED IN THE SIGNALIZATION CIRCUITS 14 6 STORAGE AND SHIPPING CONDITIONS The RN 16TM in manufacturer package should be stored in enclosed rooms at from 45 to 475 C and exposed to no more than 80 of relative humidity when there are no fumes in the air that exert a deleterious effect on package and the RN 16TM material The Buyer must provide the protection of the timer against mechanical damages in transit 7 WARRANTY AND CLAIMS CONDITIONS Novatek Electro Ltd company warrants a trouble free operation of the RN 16TM device within three years from the date of sale on condition that following terms are provided the proper connection the safety of the inspection quality control department seal the integrity of the case no traces of opening cracks spalls etc
6. NOVATEK ELECTRO LTD Research and Manufacture Company NOVATEK Electro RN 16TM LIGHT SENSITIVE MULTIFUNCTIONAL Ae 4 DAILY WEEKLY TIMER num 9 SERVICE MANUAL www novatek electro com Die 1 APPLICATION Multifunctional relay RN 16TM hereinafter RN 16TM performs the following functions Programmable real time switch daily weekly timer MIN MAX voltage relay Light sensitive photo relay Voltage indicator The RN 16TM is designed for Turning ON OFF the power load equipment according to the time schedule preset by the user Turn OFF home used or industrial single phase 240V 50Hz power load equipment in case the unallowable voltage fluctuations are detected When the voltage returns back to normal parameters the device will automatically turn ON the power load equipment with the user defined time delay Turn ON OFF the power load according to the curtain illumination level that the user may set Relay works 3 basic operation modes 1 1 and 2 mixed modes IV V 1 H daily weekly timer Il MIN MAX voltage relay Ill F photo relay IV HU daily weekly timer with voltage control function V FU photo relay with voltage control function Depending on the preset operation mode the LED display of the RN 16TM indicates the following information please see article 6 on Figure1 current time in format hours blinking point minutes 16 hours 4
7. e time setting min not exceed 1 Maximal number of events per day 60 Include ON a 30 SWITCHING o dee Ee det c 30 Events per Week oorpore eu 60x7 420 Endurance to the voltage absence retention of settings when supply voltage is absent no less than 1 month Protection degree relay IP40 terminal IP20 Commutation life for the output contacts under load 16A no less than operations 100 000 under load 5A no less than operations 1 000 000 Power consumption under load VA not more than 3 0 Weight not more than kg 0 150 Dimensions mm 50x88x65 Operating temperature C from 10 to 55 Storage temperature C from 20 to 70 3 GENERAL DESCRIPTION The mains power supply 240V 50Hz should be connected to 1 1 2 2 terminals of the RN 16TM For wiring convenience terminals 1 1 are the one connection point and 2 2 terminals another connection point Output contacts have changeover relay 3 4 In a time of exploitation of relay a strap is set 5 6 This strap is connect the internal accumulator of reserve clock motion For warehousing of device it is recommended to take off this strap that will substantially increase lifetime of accumulator Power load is being connected using terminals 3 4 Output contacts characteristics terminals 3 4 4 5 Max current Max power when Max Max long term Max c
8. e to set 1 7 values Monday 1 Tuesday 2 Wednesday 3 Thursday 4 Friday 5 Saturday 6 Sunday 7 A equal time schedule for all days of a week B equal time schedule for working days Monday Friday C equal time schedule events for weekend days Saturday Sunday To give the power supply to the RN 16TM it s necessary to connect mains voltage wires to 1 1 and 2 2 input contact terminals ATTENTION All connections of terminals should be performed strictly according to safety regulations and in the absence of voltage in the mains So before wiring make sure that the wire terminals are not under voltage Eon To every operation mode there is a curtain set of the items in menu shown on display please see Figure 1 point 6 To view all those items it s necessary to press 9 button and then scroll the parameters by pressing 9 button MODE MENU INDICATION H U F HU FU F PA Kindly remember that maximal number of events in H mode is 60 30 Turn ON events and 30 turn OFF events Number of ON OFF events is not necessarily the same Notes To set the time it s necessary to input all digits including 0 For example 7 35 morning time should be set as 07 35 After setting the schedule of events for RN 16TM it s necessary to connect the power load to the output contacts of RN 16TM ATTENTION In order to prevent possible electric shock all the connections of the power load sh
9. ge disappeared and then recovered back only on Wednesday at 6 00 in the morning So when voltage disappeared contacts 3 4 opened As soon as the power load restore and return back to normal values RN 16TM will turn ON the power load again but according to the preprogrammed schedule of operation So at 6 00 when the power return it will turn ON the power load and at 8 00 in the morning that will turn it OFF according the schedule 4 FIRST STARTUP PROCEDURES AND OPERATION ALGORHYTM For preservation of working capacity of an inner clock when disappearance of voltage it is necessary to establish a strap 5 6 Figure 1 Preliminary start up procedures include the following steps esetting of the current time and the day of a week esetting the schedule of events exact time values and days of a week when the power load should be turned ON and turned OFF as per users requirements esetting the voltage tripping thresholds for MIN MAX allowed voltage values esetting the delay times to turn ON for UPPER LOWER voltage thresholds esetting the autoreclosing time delay esetting the level of illumination if necessary If in the menu some parameter or event is seen blank then the event or parameter in not set When setting the time event schedule it s possible to adjust the following parameters turn ON time d01 x turn OFF time CLOC current time where 01 is number of event ON OFF x days of a week it s possibl
10. lue in the dAY 1 menu range 1 7 that corresponds to the actual day of a week 5 Press and enter the b Set the value from 0 menu to set the current Lac to 2 to that hour blinking tens corresponds to of hours current hour position 6 Press and set the lt gt Setthe value from 0 current hours to 9 to that blinking hours corresponds to position current hour 7 Press and set current b Set the value from 0 minutes to 5 that blinking _ tens corresponds to of X minutes current tens of position minutes 8 Press and set current b Set the value f mints E ie hat conesponds blinking to current of minutes minutes position 9 Press and Exit the menu 2 Loc if the time was set DEDOS successfully 4 SETTING THE TIME SCHEDULE 1 Perform steps 1 3 of the previous section 3 CLOC 2 Select E01 item 4 3 Press and set the day of b Set the day ofa a week week 1 7 A b c 4 Press and set time to Repeat Steps 5 8 turn ON the power load Ls of section 3 2 8 Action 5 Indication 5 Action Indication o m a 5 Press and exit the menu 4 lt gt Set the next turn ON time if necessary To set the time program for all next turn ON events it s necessary to perform 2 5 points of section 4 6 Select 401 item 4 7 Perform steps 3 5 of the section 4 lt Exit the menu 5 SETTING THE
11. mmed in the RN 16TM to enter the menu for adjustment of parameters events current time setting menu time setting for turn ON time setting for turn OFF setting for the required day of the week menu to set the voltage threshold values upper voltage threshold setting lower voltage threshold setting time delay to turn OFF when high voltage detected if voltage is more than upper voltage threshold value time delay to turn OFF when low voltage is detected if voltage is less than lower voltage threshold value time delay to turn OFF when high voltage is detected if voltage is more than upper voltage threshold value 6 illumination level threshold setting Important notes Quality of the mains voltage power supply doesn t influence on the preprogrammed operation schedule of the RN 16TM So after the normalization of the voltage parameters power load will be turned ON again but according to the time schedule preset by the user If mains voltage was absent not more than 1 month device was disconnected for 30 days all the parameters and settings will be safely kept in the RN 16TM memory Output contacts of the relay will be kept in a cold initial state For example RN 16TM was preprogrammed such a way that every day of a week it turn ON the power load at 22 00 and then at 8 00 in the morning of next day it turns the power load OFF Let s assume that at 22 30 on Monday mains volta
12. or photodiode 4 menu control buttons gt entry into menu parameter input save the parameter and menu exit lt gt scrolling buttons 5 8 wiring terminals 6 seven segment indicator display 7 green LEDs to indicate the operation mode of the relay 9 strap of internal accumulator set at the use of relay during storage to take off a strap FIGURE 1 Controls description and dimension diagrams 2 TECHNICAL PARAMETERS Rated voltage V 240 Lowest voltage level sufficient for the RN 16TM operation V 140 Highest permissible voltage V 320 Tripping voltage thresholds V Lower threshold teet 150 210 Upper threshold 230 320 Adjustment accuracy for the voltage tripping thresholds V 1 Illumination level adjustment range Lx 0 175 4 Voltage measurement accuracy V doesn t exceed 1 Voltage hysteresis returning ratio V 5 Illumination level hysteresis returning ratio 12 Adjustable reaction time delay to Max Min voltage interruptions sec 0 9 9 Autoreclosing time delay the RN 16TM will automatically close the 0 9 9 contacts turn ON the power load as soon as the tripping parameters return to normal values sec Fixed reaction time to changes in illumination level sec 12 Accuracy of the time clocks seconds per day not exceed 3 Accuracy to adjust schedul
13. ould be performed according safety regulations and on the de energized RN 16TM To preprogram the RN 16TM according to the desired mode of operation and input the required time schedule it s necessary to follow the steps shown in the table below in table example values of parameters are shown and the User may change them as per requirements a E S 2 Action 5 Indication 5 Action Indication o m a 1 TO SET THE REQUIRED MODE OF OPERATION 1 Press and enter the menu 2 Press lt gt Choose the operation mode 3 Press again and while keeping button pressed choose the required blinking dot operation mode bdd ills TI TI ic 4 Press 42 lt To exit menu press 2 times ET 2 TO SET MIN MAX VOLTAGE THRESHOLDS AND TIME DELAY SETTINGS Perform steps 1 4 from the previous table section 1 choose the operation mode es 2 9 Action 5 Indication 5S Action Indication N co n 1 Press end enter the menu 2 By scrolling buttons find lt gt U PA mode Press and while keeping 5 lt gt Set upper voltage blinking dot Press and choose upper voltage threshold button pressed set the required upper voltage threshold then release the button when the setting is done B BIE blinking dot threshold value in the range 230 320 Press and save the selected value in the device memory
14. ress and while keeping gt b Set the desired value button pressed set the required value then blinking dot blinking dot release the button when the setting is done 13 Press and save the 42 selected value in the device memory Save and Exit 14 Select dL 90 item lt gt 41 90 turn OFF time delay in case 5 blinking dot undervoltage detected 15 Press and while keeping gt lt gt Setthe desired value button pressed set the peus dL 95 required value then blinking dot blinking dot release the button when the setting is done 16 Press and save the selected value in the dL 95 device memory Save blinking dot and Exit 17 Select dE 50 item 4 turn ON time delay blinking dot 18 Press and while keeping 4 button pressed set the required value then blinking dot blinking dot release the button when the setting is done 19 Press and save the 42 55 42 Press and exit the selected value in the linking dot menu device memory Save and Exit 3 CURRENT TIME SETTING 10 Perform steps 1 4 from the previous table section 1 choose the operation mode 1 Press and enter the menu T a S g icut 9 Action S Indication 5 Action Indication o a a 2 By scrolling the menu 4 items find H PA 3 Press and enter the Loc 4 Press and enter the GAY lt gt Set the va
15. urrent under U 250V contacts are Switch safe voltage under U 30V A C closed power A C D C D C 0 4 5A 5000VA 4000VA 380 150 V 5A Cosq 1 0 16A zi5is If the RN 16TM detects the unallowable OVER UNDER voltage then it will turn OFF the power load by opening the contacts 3 4 and in case of using the contactor that will turn OFF the power for the magnetic coil of the contactor and thus disconnect any required equipment As soon as voltage parameters restore and return back to normal values RN 16TM will automatically turn ON the power load within the preset autoreclosing time delay Present status of the relay ON OFF states of the output contacts are indicated by green LED light ON in the left upper corner of the front panel Figure 1 point 1 Current operation mode of the RN 16TM is marked by green LEDs F U H on the front panel Figure 1 point 7 All the adjustments and parameter settings could be subdivided into two groups BASIC and PARAMETER settings BASIC SETTINGS to set the operation mode F H of the RN 16TM to set the operation mode and curtain user required set of parameters there are 2 independent sets of parameters programs that the user may keep in the device memory SE 1 to choose one of the available set of parameters SP1 or SP2 CL 1 to clear delete current set of parameters PARAMETER SETTINGS to view the events parameters preprogra