Home
Solid State Logic C100 HD
Contents
1. Page 12 m TL TE Es T TE Ts TE 115 8000S EIC Tel 0008 ES c a O 24 L 6 gt 6 2 2 E gt D da 0 A 9 S 24 EERE L 2 8 LE De 1 L O m 21 1
2. mais GNE ig 188 188 XGA TCPAP 1 8 XGA s L USB Ce Hoi sea LUN Ethernet Hub Switch Facility s TCP IP Network Console Connector Panel lo lo Page 26 Section 5 Installation Wiring Blackrock to Console Surface Connection Network Cables The Blackrock processor is equipped with two separate network connections Both use standard RJ45 termination and cabling but are different protocols so must be kept separate at all times The first is labelled SSL and is reserved for the connections to the console control surface and the optional redundant Blackrock processor The second connection is a standard TCP IP Ethernet port which should be linked to a PC within the facility s internet network This machine can then be used for project backup software updates and for SNMP status reporting and maintenance support The SSL network connection is t
3. 0 0 9 0 9 0 9 9 O MORSE 30 Stagebox Page 20 Section 4 System Components MORSE System option The MORSE MOdular Resource Sharing Engine system provides a cost effective scalable solution for the sharing of local or remote audio I O and managing control data The system is specifically designed for on air reliability and features optional redundancy on all data links and fault tolerant proprietary software The system comprises a central router to which remote stageboxes and consoles may be connected via optical MADI links to provide a resource sharing solution The router is available as a 3U rack with up to 24 individual links available or as a 6U rack with up to 48 links Stageboxes can be connected to the router so that any I O signal is then able to be allocated to any Blackrock processor connected to the router If however resource sharing is not a requirement stageboxes can be directly connected to the processor Each stagebox can each be fitted with up to 56 channels of I O Plug in modules a
4. Y T x bs AES tu 1 OO lt imc HD L Solid State Logic LEFT RIGHT SOUND Meter Input Connectors Lj BO D ecce CIOOHDS Installation Guide Page 40 Section 5 Installation Wiring Meters and Phasescope The Centre Section of the CIOOHDS console is fitted with two off analogue moving coil meters The meters supplied as standard are VU scale but PPM versions can be specified In addition the Master Section can also be fitted with an LCD phasescope Three standard phasescope types are available to order the DK Technologies MSD600C 5 1 or MSD600M or the RTW10830 SurroundMonitor The RTW 10830 has eight digital input signals with loop through outputs and eight analogue input signals plus remote control port Note that two of the analogue input signals will be split inside the console and also be used to feed the left and right mechanical meters The MSD600C 5 1 phasescope has inputs for 6 digital signals 3 AES EBU pairs plus a serial diagnostic port The MSD600M uses the same display panel as the 600C meter but has slots at its rear into which a range of input and output inte
5. Appendix A Specifications Notes Excludes connectors cables Depending on I O fitted Maximum Typical 10 AC only Approximately Variable speed fans Page 49 unused Wordclock Duplex LC fibre multimode 25 way D type male Unit gt lt 2 2 53 Value 7 665 19 449 344 17 21 500 350 100 240 5 6 2 3 0 95 45 55 45 60 IEC male RJ45 100 baseT BNC 750 25 way D type female Remote Chassis Condition Case only without rack ears 5 Mic cards Mic 2 analogue digital card Range Maximum over voltage range Thermal current trip No fuses Front Rear Power in and 2 Network Sync out Madi 1 4 GPI Input GPI Output Parameter Height Width Depth Weight f Heat Dissipation Voltage Current Power Factor Fusing Noise Connectors RIO units must be supported on rack shelves Do not rely on the rack ears alone Connectors Viewed From Wiring Side Socket A N I V 8 7 6 5 4 3 2 1 gt zzrmxcr 87654321 d 2 x ee 1 S 2 6 Connectors Viewed From Wiring Side Plug C O 12345678 A B D E F ka K N P
6. 12345678 Connectors Viewed From Wiring Side 29mm x 69mm Dimensions CIOOHDS Installation Guide Appendix B Connector Details 70 19 x 60mm approx 8 2mm typical XLR 3 Pin imensions D Cable Dia Pinout for balanced audio Screen Ground Hot ve Cold ve 55 x 15mm approx 8mm typical Hood 68 Pin Pin 2 Pin 3 D Type Multipin ZB NU 25 way Dimensions Cable Dia DL 96 Pin Page 50 Appendix C Connector 515 Appendix C Connector Pinouts Connector Pinouts CI00HDS Console TB Out Location Connector panel Connector Type XLR 3 pin male Pin Description Notes Chassis screen 2 signal 3 signal Meter Inputs 6 Location Connector Panel Connector Type 25 way D type male Pin Description Notes VU or PPM only Notes 0 Circuit input Left meter Input I4 Circuit input And Left VU PPM meter 2 2 15 Circuit 2 input Input 2 3 Circuit 2 input And Right VU PPM meter 16 4 Circuit 3 input Right meter Input 3 17 Circuit 3 input 5 18 Circuit 4input Input 4 6 Circuit 4 input
7. HDS Installation Guide CIOOHDS Installation Guide Solid State Logic SOUND VISION C100 HDS Digital Broadcast Console Installation Guide Version 1 1 0 82BCBGOIB Solid State Logic SOUND VISION Begbroke Oxford England OX5 IRU 44 0 1865 842300 320 West 46th Street 2nd Floor New York NY 10036 USA 1 1 212 315 5757 Wilshire Blvd Suite 401 Los Angeles 90036 USA 1 1 323 549 9090 3 55 14 Sendagaya Shibuya Ku Tokyo 151 0051 Japan 81 0 3 5474 1144 7 bis rue de la Victoire le Blanc Mesnil Paris 93150 France 33 0 1 48 67 84 85 Via Timavo 34 20124 Milano Italy 39 0 39 2328 094 Visit SSL at URL http www solid state logic com Solid State Logic Rights reserved under International and Pan American Copyright Conventions C100HD C100HDS C200HD C300HD Blackrock RIO NetBridge Solid State Logic and SSL are trademarks of Solid State Logic All other product names and trademarks are the property of their respective owners No part of this publication may be reproduced in any form or by any means whether mechanical or electronic without the written permission of Solid State Logic Oxford England As research and development is a continual process Solid State Logic reserves the right to change the features and specifications described herein without notice or obligation E amp OE Page I 46 47 48 49 50 51
8. 19 7 Circuit 5 input Input 5 20 Circuit 5 input 8 2 Circuit 6 input Input 6 9 Circuit 6 input 22 10 Circuit 7 input Input 7 23 Circuit 7 input Il 24 Circuit 8 input Input 8 12 Circuit 8 input 25 13 Note If both the RTW phasescope and mechanical meters are fitted refer to the RTW circuit allocations Page 51 CIOOHDS Installation Guide Meter Inputs Digital Location Connector panel Connector Type 25 way D type female Pin Description Notes MSD600C 5 I Notes RTW10830 Circuit input AES EBU in 1 2 AES EBU out 7 8 14 Circuit input 2 n c 15 Circuit 2 input AES EBU in 3 4 AES EBU out 5 6 3 Circuit 2 input 16 4 Circuit 3 input AES EBU in 5 6 AES EBU out 3 4 17 Circuit 3 input 5 n c 18 Circuit 4 input AES EBU out 2 6 Circuit 4 input 19 7 Circuit 5 input AES EBU 7 8 20 Circuit 5 input 8 n c 21 Circuit 6 input AES EBU in 5 6 9 Circuit 6 input 22 10 Circuit 7 input AES EBU in 3 4 23 Circuit 7 input Il n c 24 Circuit 8 input AES EBU in 1 2 12 Circuit 8 input 25 13 n c Diagnostics and Control Connector panel 9 way D type female Phase Scope Location Connector Type Pin Notes MSD600 Notes 0 Chassis Switch common 6 Mode 2 Rx Data Select 7 Memo 3 Tx Data Gain 8 Reset 4 Shift 9 5 Connector will
9. EFEERERER O FEERERRR HEH E 121 2 OTI i i 51 FE Q d 7 s Enid Ll cn O i e i CT EEE 5 a gt a Lo Er if 3 le 8551933920 tO EFEEEEEER nu 1 8 al 8 Vo FERRE nO 9 d eu e is DE ERERERERS ird Lo lic fh iO i do 82227127 E z m ULI 2222 77 44 h Q BI 4 JA BO 4 20333333 5 tO 1 dida CM x EEEEEEEER 1 O N 1 604 22222 1 5 vale 1 EFFEERERIE i i CIOOHDS Channel Bay Layout CIOOHDS Installation Guide Section 4 System Components Section 4 System Components This section provides greater detail about the main units in the system See Appendix A for specifications and Appendices B and C for connector details and pinouts CIOOHDS Console Each console control surface will consist of the Centre Section and can be specified to have from 16 to 64 channel faders in groups of
10. Ugl el ug s Redundant Blackrock with Dual RIO _ 126 channels or 62 channels with redundant link CIOOHDS Installation Guide FF mm DAT j HITS PIAF gu bu Page 44 Section 5 Installation Wiring Remote I O RIO Chassis and Blackrock Processor On Air Redundancy In its simplest implementation a C100 HDS will have a single Blackrock processor and a single RIO unit connected by fibre MADI cables with a bandwidth of up to 254 bi directional audio channels plus control and status data This arrangement does not offer any hardware redundancy if either unit or any of the cables between them is lost However it can be expanded and configured to provide several levels of redundancy for the audio interface audio connection and processor core to suit a facility s particular requirements Redundant RIO link To pr
11. I I I Blackrock Processor SSL I 2 Service d 0 i lt gt File Management and Terminal Access Direct i 1 0 LA 1 1 0 0 e UTI t ICE m i 0 Network lt gt File Management and Firewall Terminal Access Network Internal Network External Network Page 36 Section 5 Installation Wiring File Management In order to manage and update the Blackrock s operating software it will be necessary to have access to a computer with an Ethernet connection The computer selected can be an existing machine within the facility connected remotely via an Ethernet switch it would be an advantage if the computer used was in the same room as the Blackrock processor Alternatively a computer may be connected via a direct Ethernet link note that the cable used for this arrangement will need to be of a crossover variety Connection should be made to the TCP IP port IP Address To initially determine the IP address of the Blackrock motherboard s TCP port it will be convenient to have access to
12. The CIOOHDS system is CE compliant Note that the majority of cables supplied with SSL equipment are fitted with ferrite rings at each end This is to comply with the current regulations and these ferrites should not be removed If any of the console metalwork is modified in any way particularly the addition of holes for custom switches etc this may the adversely affect the CE certification status of the product FCC Certification C This equipment has been tested and found to comply with the limits for a Class digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Instructions for Disposal of WEEE by Users in the European Union The symbol shown here which is on the product or on its packaging indicates that this product must not be disposed of with other waste Instead it is the user s responsibility to dispose of their waste equipment by handing it over to a designated collection point for recycling of waste elect
13. 8 Note A group of 8 faders and controls and its frame is termed a bay Refer to page 46 for frame dimensions The number of physical faders fitted to a console surface does not limit the number of processing channels available this is determined solely by the quantity of DSP resource fitted to the Blackrock processor DSP processing is available in quantities of 64 96 or 128 channels Each console channel bay comprises four individual sections Faders Channel Control tile Master Channel tile and TFT meter panel The Master Channel tile provides physical access to all operational controls and can be assigned to any of the channels in the console As a minimum it is only necessary to have one Master Channel tile fitted to a console as this can be used to access any DSP channel specified although for convenience and additional flexibility Channel Master tiles can be fitted to any bay Fitting a Master Channel to either side of the Centre section will allow full channel control to be retained even if one of the two console control cables becomes disconnected The Centre Section is always fitted with two analogue mechanical meters these are VU scale as standard but can be specified to be PPM Additionally there is space available into which a 6 or 8 channel LCD phase scope can be fitted There are three types available 10830 analogue plus digital MSD600C 6ch digital or the MSD600M modular customisable Not
14. Cards are available with the following functions 24 channel analogue I O 64 channel digital with either fibre or copper connection and 12 channel microphone input Cards can be fitted in any combination Cards must be installed starting with slot one directly below the Interface card and added in order See the following page for I O card details Unused slots must be fitted with a blanking panel supplied to maintain the correct airflow through the rack Fibre Connection RIO units are connected to the Blackrock processor using duplex fibre optic cabling The connectors required at each end are duplex LC type flat end not APC The fibre interfaces are available in two versions singlemode and multimode The fibre specification chosen determines the maximum distance that the cable can be run without loss of data Singlemode and multimode interfaces and connectors are almost identical in appearance but are operationally incompatible the standards must not be mixed within a system Generally singlemode cables are coloured yellow and multimode cables are coloured orange Unless specified otherwise the RIO and Blackrock interface adaptors will be fitted with the multimode version Console systems are supplied with one 2m multimode fibre cable for each RIO to Blackrock link It is the responsibility of the facility to provide longer or additional fibre cables necessary to connect the Blackrock processor to the RIO units Stan
15. VGA monitor and USB keyboard these should be connected to the Blackrock motherboard s VGA and USB ports Once booted the motherboard will be running a Linux graphical desktop Present on the desktop will be an application called Terminal Run the application and type the command my_blackrock followed by the Return key The application will respond with the IP addresses of both the internal SSL console network and the internet TCP IP addresses Remote Diagnostics The external access to the Blackrock processor via an IP network allows access to remote diagnostics using SNMP Many of the console s and Blackrock s operating parameters are available to allow monitoring and interrogation Page 37 Analogue CIOOHDS Installation Guide Talkback System CIOOHDS Console RIO Rack oY Centre Section Master tile I IL 05 Internal GAIN COMPRESSION o Mic Talkback Output per x Cet 1 card Console Connector Panel DD 22 Bm Gane ODODO M o Talkback Output Page 38 Section 5 Installation Wiring Talkback and Oscillator Talkback Connection The C100HD
16. VISION LEFT RIGHT Page 42 Section 5 Installation Wiring User Option Switches The meter panel in the Centre section is fitted with 16 switches which are available for user defined functions The switches are linked to the console s macro system so that each switch assigned to a range of internal console functions They can also be programmed to operate a relay closure on the RIO Interface card The lower four positions are fitted with physically latching switches This enables them to be used for internal switching functions such as external TFT input switching see page 23 It is possible to engrave custom labels for user option switches contact SSL s Project Engineering Department for details It is the responsibility of the facility to ensure that all cabling required to enable correct operation user option switches is installed prior to the console being commissioned Page 43 Blackrock with Single 060 254 channels or 126 channels with redundant links Blackrock with dual RIO SASS AS pece 254 channels or 126 channels with redundant links 071 SE emu LE e CI Redundant Blackrock ff ae Z Sr 126 channels 2 or 62 channels with redundant link
17. can be used for direct connection of an analogue XGA monitor to facilitate file management and backup functions Serial Port RS232 D9 female for serial connection to Probel routers to facilitate router name transfer CPU and DSP This single PCie card performs all the system DSP and processing functions be specified as one of three versions to support 64 96 or 128 full function channels at 48kHz simultaneously Processors specified with less than 128 channels can be subsequently expanded via a license upgrade The DSP card is fitted with the following connectors Network 1 amp 2 Console network output connectors Connector Net must be linked to the built in hub Sync in BNC input connector for system reference A feed of sync must be supplied The following are suitable sources Analogue Video black amp burst or composite Wordclock or AES3 id 750 USB SSL Service use only Mezzanine 1 amp 2 A Madi interface card fitted with four off SFP fibre sockets Each of these sockets can be equipped with a duplex LC fibre interface adapter for connection to a remote I O unit Each Madi port provides up to 647 audio channels The fibre multiplexers fitted as standard are the 50 125 multimode version which will function at cable lengths of up to 550m 9 125 singlemode multiplexers which can function at distances of up to 2km are available to order at additional cost One mezzanine card ports 1 4 is included as standa
18. control surface and the Blackrock processor rack are fitted with auto sensing power supplies and will function at any voltage from 100 to 240 volts without adjustment The console is supplied with detachable IEC type mains leads These leads are 2m in length and the cable diameter is approximately 6mm The free end of each lead is unterminated and will need to be connected to a suitable outlet beneath the console CI 00HDS systems are supplied as standard with dual redundant power supplies for on air use so is therefore fitted with two separate IEC mains input connectors The inrush current present when powering the console can be significant typically ten times the steady current so the use of slow or motor rated fuses circuit breakers is recommended See Appendix A for equipment specifications The console power rating label will be located between the two mains input connectors beneath the rear of the console Computer for File Management and Software Updates It will be necessary to have access to a computer with an Ethernet interface to be able to update the Blackrock s system software and also to archive or backup operator projects SNMP status information is also available over the IP network The machine used for communication with the Blackrock can either be connected via the facility s Ethernet network or can be a direct Ethernet connection Note that if connecting directly then the cable must be of the c
19. facility engineers Instructions for installing these cables are found on pages 25 to 35 of this manual Cables that may be required for the connection of ancillary functions meters talkback or any custom switching etc are NOT supplied by SSL and will need to be provided by the facility Refer to pages 38 to 41 for cabling information Services Provided by SSL Commissioning All CI00HDS systems include on site commissioning by an SSL engineer This is usually expected to take from 2 to 4 days depending on system size configuration and options Large systems or consoles split for shipment may require an additional 1 2 days of commissioning time You will be contacted by your local SSL office or agent shortly before delivery to arrange a commissioning date Training Three days of standard operator training are provided with each CIOOHDS system If required this is scheduled to take place immediately following the commissioning period and is usually carried out by the commissioning engineer A further day of advanced operator training is available at additional cost On site maintenance training is also available at additional cost Training duration can be either one day for a basic overview or two days to progress to a more advanced level Training should be requested at the time of order For all training we recommend that no more than five persons attend each session If the use of an interpreter is necessary the training peri
20. screen to match the standard operating level for the facility When assigning analogue card output channels as insert sends the routing system will automatically assign the same input channel number as the corresponding return It is therefore necessary to physically wire outboard equipment so that circuit allocation follows this arrangement Page 31 Digital 1 0 Card AES EBU Input Connectors 25 pin D type female AES EBU Output Connectors 25 pin D type female LJ AES EBU IN AES EBU OUT CIOOHDS Installation Guide Page 32 Section 5 Installation Wiring 1 0 Digital Input Output Card 1100 SSL ref 942XF The digital input card provides 32 balanced AES EBU signal pairs of input and output All circuits are accessed via 25 pin D type female connectors All inputs and outputs are balanced at 1100 and cables with the correct matching impedance must be used Refer to Appendix C for the connector pinout for this card Mating connector kits can be ordered for the card When assigning digital card output channels as insert sends the routing system will automatically assign the same input channel number as the corresponding return It is therefore necessary to physically wire outboard equipment so that circuit allocation follows this arrangement 1 0 Digital Input Output Card 750 SSL ref 942 This version of the Digital card is externally
21. the Blackrock processors must be linked together using a single crossover type Ethernet lead Refer to page 37 for further details of configuring the PC for file transfer and project backup If for either system a MORSE router has been specified then this must also be linked to the SSL network and can optionally be linked to the TCP IP network Page 27 0000000000000000 CIOOHDS Installation Guide Blackrock Rear Panel 9 9 6 2 ML 9 9 9 9 551 USB n POS a Sync Input connector RIO MADI Ports 0 RUNNING LOCKED SYNC POWER O O O ETHERNET Page 28 Section 5 Installation Wiring Sync Source The Blackrock processor must be provided with a source of sync input in order to function Suitable sources of sync are Video black burst or composite Wordclock AES3id unbalanced The sync input provides internal 750 termination RIO MADI Fibre Links The Blackrock processor
22. trims 8 channel bay add subtract Contoured side trims 32 channels with 2 legs 8 fader bay add subtract Additional leg 32 channels 8 fader bay add subtract Range 32ch max over voltage range 48ch max over voltage range No user accessible fuses Fanless Power in Main Backup Network control 1 5 USB in 1 2 USB out 1 2 Meters Phasescope in Analogue Phasescope in Digital T B audio output Parameter Height Height adjustment Width Depth Weight Heat Dissipation Voltage Current Power Factor Fusing Noise Connectors Notes Excludes connectors cables Shared between two PSUs 10 AC only Maximum Approximately Two PSUs operating Two PSUs operating NR NR Value 2 89 19 449 429 14 200 100 240 2 1 0 9 0 95 50 55 IEC male RJ45 100 baseT BNC 750 Duplex LC fibre multimode HDI5 female CIOOHDS Installation Guide Blackrock Processor Condition Case only without rack ears Range Maximum over voltage range Thermal current trip No fuses Front Rear Power in and 2 Network TCP IP Sync in Madi 4 5 8 Video out Parameter Height Width Depth Weight 1 Heat Dissipation Voltage Current Power Factor Fusing Noise Connectors 1 Blackrock processors must be supported on rack shelves Do not rely on the rack ears alone Page 48
23. via relay closure and are accessed via 25 pin D type female connectors Mating connector kits are available to order Both the input and the output circuits are fully isolated from the RIO electronics On output connectors there is a protected source of 15V available an a 0 reference is available on input connectors The input and output signals can be either latching or momentary this is individually assigned in software using the touch screen When set to momentary the input signal trigger duration must be greater than 50mS When used for discrete track arming with associated tally the tally must return to the same number input as the arming output signal ie the tally for GPI Out will be on GPI In 1 The switch closure is by DIL relay Contact rating is 100Vdc 125Vac 100mA max Do not use the output contacts to directly switch capacitive or reactive loads always use an external relay with a suitable contact rating O Contact A GPI Output circuit Contact The input is triggered by an or DC voltage between 4V and 30V The current drawn approximately 0 GPI in 2 1 g Input A gt GPI Input circuit En 1 Page 35 CIOOHDS Installation Guide NetBridge Installation C100HDS Console TCP IP Network I I I SSL Console Network E I I I I I I I I I I I I
24. 40V without adjustment The mains rating label is located adjacent to the earth bolt on the power inlet panel b Connect both the Blackrock s IEC mains leads to appropriate mains supplies Refer to the notes above for suitable supply provision lt Console Address is only necessary to refer to the console address switch setting if more than one CIOOHDS console is being connected to the same Ethernet network The address switch is located on the console connector panel it is a 16 position rotary switch Its function is to identify different consoles connected to the same Ethernet network The default setting for this switch is If a second console is added to a network then the switch should be set to the 2 position and subsequent positions for additional consoles Address 0 is not used Console Address Switch Default setting Page 25 CIOOHDS Installation Guide Control Surface Wiring Diagram Single Blackrock 2 x 0 5m Network cable Blackrock Rear Panel 0000000000000000 Facilitys TCP IP Network 2 x Console Network cables SSL Network TCP IP Network Console Connector Panel Control Surface Wiring Diagram Redundant Blackrock Im Network cable
25. 53 57 59 Contents Introduction Safety Considerations Safety Warnings CE FCC WEEE Certification and Directives Pre Installation Information Services Provided by SSL Physical amp Structural Requirements Console Service Access Diagram Blackrock and RIO Service Access Diagram Technical Requirements System Components Console Frame The Blackrock Processor Remote I O Rack RIO RIO I O Cards MORSE option Script Tray option Loudspeaker Shelf option TFT Video Switcher option Phasescope option Installation Detail Power Supplies Console Connection Console ID Address Sync Source MADI Link Connections MicAmp Card Analogue Card Digital Card RIO File Management Talkback and Oscillator Mechanical Meters and Phasescope Wiring User Option Switches Redundancy Options Appendices Console Footprint Equipment Specifications Console Blackrock RIO Connector Details Connector Pinouts Console RIO Audio Interfacing Environmental Specification A m CIOOHDS Installation Guide Section Introduction The object of this manual is to provide purchasers of the CIOOHDS Console Blackrock processor and RIO stageboxes with information in the following areas Safety considerations Installation requirements Items supplied Main components and optional items Installation Physical assembly Electrical connections and cablin
26. G7 14 D6 6 G8 15 D7 E7 F7 16 D8 E8 F8 17 LI KI JI 18 L2 K2 J2 19 L3 K3 HI 20 L4 K4 H2 21 L5 K5 H7 22 L6 K6 H8 23 L7 K7 J7 24 L8 K8 J8 Page 54 Appendix Connector Pinouts Notes Pin 13 unused 942 DIO 25 way D type female Cold Screen 12 25 23 9 22 20 8 6 19 17 5 3 16 14 2 AES EBU In 1 8 9 16 17 24 25 32 Location Connector Type Hot 24 10 21 7 18 4 15 amp WN N m a N N N o N N D a m ES e m 0000 6000 66000 66000 66000 66000 N Page 55 For 75 card version A 9000 OOOO m o m e 4 N N a N N 3 0000 0000 N N e AES EBU Out 1 8 9 16 17 24 25 32 Location 942 DIO Connector Type 25 way D type female Cct Hot Cold Screen Notes 24 12 25 Pin 13 unused 2 10 23 3 21 9 22 4 7 20 8 5 18 6 19 6 4 17 5 7 15 3 16 8 I 14 2 AES EBU IN 5 ie s nob 0 0 0 0 0 0 00 1 J p lt 25 32 17 24 AES EBU OUT DO 0 0 CES T i v 25 32 17 24 HO Digital 1 Card 942 BNC Breakou
27. MADI connections feed each of the Blackrock cores When MADI link redundancy is configured the system is resilient enough to allow loss of up to 4 MADI connections and one complete Blackrock core without any loss of console capability or audio Any MADI links not used for connection to an SSL RIO may be used instead for connection to any other MADI equipment including other manufacturers Routers and interfaces that comply with the AESIO specification for MADI This includes redundant links to those pieces of equipment that support this mode of operation Page 45 Page 46 01359 1 60 20 61 0 fesodold 240 61 jeeus 29 2 6 Aq quello sjeuueu ZE SCHOOLO 1491003 21801 311 Console Footprint Drawing CIOOHDS Installation Guide Appendix Specifications Notes Add 36mm each side Approximately Approximately 10 AC only Approximately Page 47 Value Unit 1006 mm 0 10 mm 1431 mm 285 mm 72 mm 926 mm 123 kg 26 kg 6 5 kg 400 W 80 W 100 240 V 32 1 A 5 1 1 9 0 95 IEC 3 pin male 10 RJ45 100 7 USB A female USB B female 25 way D type male 25 way D type female XLR 3 way male Appendix A Specifications CIOOHDS Console Condition To top of meter trim 32 channels with flat end
28. S console contains a built in talkback microphone and amplifier The microphone is located on the Centre Section master tile adjacent to the main monitor pot The Mic amp circuit features an inbuilt compressor and the output signal is balanced and at line level The TB output signal is available on an XLR 3 pin male mounted on the console connector panel It will be necessary to install a single balanced audio cable between the talkback output connector on the console and the analogue input DL connector in the RIO The circuit chosen can then be assigned as the talkback source via the console s routing system Oscillator Connections The CIOOHDS features an inbuilt software oscillator This signal can be assigned to any output without additional cabling Alternatively an external oscillator either analogue or digital mono or stereo may be used In this instance one or two circuits should be allocated on the appropriate input card these signals can then be allocated via the touchscreen Refer to Appendix C for connector pinouts It is the responsibility of the facility to ensure that any cabling necessary to make use of the talkback and oscillator functions is installed prior to the console being commissioned Page 39 Phasescope Digital Inputs female _ Phasescope and VU Analogue Input male 0 9 PSU1 PSU2 Centre Section Meter Panel Space for phasescope
29. ation for connection of balanced to unbalanced equipment is to isolate unbalanced connections by using a balancing transformer Balanced Unbalanced One screen connected to chassis Recommended OV Chassis Page 57 CIOOHDS Installation Guide inch 25 4mm exactly Im 3 3 roughly mile 1 600m roughly IKg 2 2 Pounds roughly Page 58 Appendix E Environmental Specifications Page 59 5 to 30 Deg C 20 to 50 Deg 15 Deg C Hour 20 to 80 5 to 90 29 Deg C non condensing lt 0 2 G 3 100Hz lt 0 4 G 3 100Hz lt 2 G l0mSec Max lt 10 10mSec Max 0 to 3000 m 0 to 12000 m Operating Non operating Max Gradient Operating Non operating Max wet bulb Operating Non operating power off Operating Non operating Operating Non operating Appendix E Environmental Specification Temperature Relative Humidity Vibration Shock Altitude Above sea level CIOOHDS Installation Guide Page 60
30. be fitted to one spare cutout on connector panel 01 03 Refer to console specification manual for actual location Page 52 Appendix Connector Pinouts Page 53 RIO Interface card GPI Inputs 1 12 13 24 25 way D type male Notes 12B Location Connector Type Description Input Input Input Input Input Input Input Input Input Input Input Input Input Input Input Input Input Input Input Input Input Input Input Input 0V Pin 20 21 22 23 24 25 GPI Outputs 1 12 13 24 RIO Interface card 25 way D type female Notes 450mA total across all connectors 12B Location Connector Type Description Output Output Output Output Output Output Output Output Output Output Output Output Output Output Output Output Output Output Output Output Output Output Output Output 15V Pin 20 21 22 23 24 25 Connector Pinouts RIO CIOOHDS Installation Guide Analogue I O Card 944 1 Analogue In Out 2 2 Location 944 Analogue Card Connector Type DL96 female ee Cct Hot Cold Screen Notes AI BI CI All other pins unused 2 B2 C2 so 3 A3 B3 C3 iun 4 A4 B4 C4 HER 5 A5 B5 C5 9 6 A6 B6 C6 7 A7 B7 C7 8 A8 B8 C8 9 DI EI FI 10 D2 E2 F2 Il D3 E3 12 D4 E4 G2 13 D5 ES
31. cted to either the SSL or TCP IP networks Page 29 CIOOHDS Installation Guide Micamp Input Card Analogue I O Card ANALOGUE IN 1 24 Ok Analogue Input Connector DL96 female Mic Input Connectors XLR 3 female ANALOGUE OUT 1 24 9 9g 1 a EEE QU UU en Analogue Output Connector DL96 female Page 30 Section 5 Installation Wiring 1 0 SSL ref 968 Each micamp input card provides 12 high quality microphone circuits The inputs are accessed via standard XLR 3 female connectors Refer to Appendix C for the connector pinouts SSL is able to supply mating connectors if requested at additional cost It is always highly recommended that the 48V phantom power is switched off via the console control surface before connecting any microphones 1 O Analogue input output Card SSL ref 944 The analogue card provides 24 circuits of electronically balanced input and output These circuits are accessed via Canon DL 96 way female connectors mating connectors are available to order Refer to Appendix C for the connector pinouts The default line up level for analogue I O is 008 5 18dBu This level may be globally altered and can range from 9dBu to 24dBu The value can be adjusted from a setup
32. ctors on the power input panel beneath the rear of the console Mains Isolation and Over Current Protection An external disconnect device switch is required for this equipment which must be installed according to current wiring regulations A detachable power cord if fitted to this equipment is a suitable disconnect device otherwise an approved disconnect switch is required the rating of which is defined in the product specification Appendix A and on the equipment itself An external over current protection device is required to protect the wiring to this equipment which must be installed according to the current wiring regulations The fusing or breaking current is defined in the product specification In certain countries this function is supplied by use of a fused plug Some units specifically those fitted with PSU Redundancy utilise multiple power sources This is clearly marked on the equipment The finished installation must also be clearly marked to ensure that all sources of power are removed before servicing work begins Physical Safety The console surface is too heavy for one person to move ensure sufficient manpower is available when positioning the console Take particular care when removing a fully populated RIO chassis from the equipment rack If the console trim is removed for any reason then there may be sharp edges exposed on the frame metalwork Page 4 Section 2 Safety Considerations CE Certification
33. dard Cable specification Maximum cable length Note Multimode LC LC duplex 50 125 550m 1 800ft Default fitment Singlemode LC LC duplex 9 125 2 000m 6 560ft Cost option Page 17 Page 18 Digital Card Analogue 1 0 Card Mic Input Card 24 1 ANALOGUE OUT poo Gero 7005520 85 Of 9 88886 5 1 OJ 00005050 5985855 Ole AES EBU IN CIOOHDS Installation Guide Section 4 System Components RIO Micamp Card The microphone input card provides 12 input channels accessible via standard XLR 3 pin female connectors The card has been specifically designed to operate in a broadcast environment and meets recognised performance standards The card is fitted with RF input filtering a high speed analogue limiter and features high input CMRR Phantom power is available RIO Analogue 1 0 Card The analogue card provides 24 channels of balanced line level input and output At least one analogue card will need to be included if analogue monitor amplifiers are being used The connectors used for input and output are Canon 6 types Mating connector kits and a contact crimp tool can be supplied as cost options Refer to
34. dix E contains the environmental specification for SSL equipment Cable Ducting Cable ducting will be required between the console and the Machine room as well as to any outboard racks and the recording areas The ducting provided should be of sufficient size such that approximately 50mm x 35mm is available for console surface connection This should be sufficient for the analogue and digital cabling for metering and the T B Mic etc in addition to the console connections The connectors for all control and interface cables are located beneath the console s Centre Section The connector panels are orientated so that cables will exit downwards at the rear of the desk It is not possible to route cables through the console legs The mains input connectors are located on a separate panel This panel is normally positioned in the bay to the left of the Centre Section Service Access Access to all electronic assemblies within the frame is from either the front or above the console The power supplies are located in the knee panel area There are PCB assemblies located behind the channel TFT meter screens To remove a TFT screen it will be necessary to remove the top trim This trim is secured using screws along the rear of the top edge If the console is being built into restricted space as in some mobile installations then allow sufficient clearance above the top trim for access to the fixing screws Clearance for service access will als
35. e that the console frame is supplied without moulded side arms as standard to reduce the overall width Contoured side arms are available but need to be specified as an option These will add 72mm to the overall console width A dxf CAD drawing of the 32 channel frame layout be downloaded from the CIOOHDS area of SSL s website Page 13 0 0000000000000000 Blackrock Processor Front Blackrock Processor Rear Mezzanine cards 2 Network switch Madi x 4 USB 8 7 6 5 5 4 3 2 T NET 1 2 SYNC USB XGA SSL TCP IP USB n DAW Sync Serial XGA USB SSL In Port SSL TCP IP Network Network Network CPU and DSP Motherboard Rear View CIOOHDS Installation Guide 9 Page 14 Section 4 System Components The Blackrock Processor The Blackrock processor is a 2U high 430mm deep excluding connectors rack unit The unit is based on an industry standard industrial PC chassis running 55175 operating software There no 3rd party licensing requirements Behind the removable front pan
36. el are one or two swappable SATA drives the filters for the cooling fans and a protected mains switch At the rear of the rack are the removable PSU units the console network and terminal connections the optical Madi ports for I O and a serial port Power supplies The unit is fitted with two removable power supplies either of which is capable of powering the Blackrock chassis so as to provide fault redundancy The units are autoranging and are fitted with a standard IEC male connector for mains input Motherboard This card is the processor for the system files and for project storage and also functions as the interface for remote diagnostic servicing and storage capability when connected to an IP network The Motherboard is fitted with the following connectors TCP IP Network network connection will need to be connected to the facility s TCP IP Internet service to facilitate remote diagnostics SNMP project backup and system file management SSL Network Console network connection must be linked to the built in hub Note that the SSL network is used to transfer control surface data which is not TCP IP protocol Do not combine this network with the TCP IP network DAW Reserved for the implementation of IP MIDI Not currently available USB 1 amp 2 Standard peripheral USB can be used for direct connection of a keyboard and mouse to facilitate file management XGA Standard analogue video output combined with above
37. g System options Specifications and Physical dimensions Pinouts of standard connectors The information provided by this manual is relevant to all of the versions of the CI00HDS Those aspects of the CIOOHDS system which may be subject to specific customisation Master Channel layout and meter panel as examples will be documented in the Custom Specification information for a specific console The Custom Specification information which details the actual console as built will be found in Section 10 of the console s Service Manual Page 2 Section 2 Safety Considerations Section2 Safety Considerations This section contains definitions and warnings and practical information to ensure a safe working environment Please take time to read this section before undertaking any installation work Definitions Maintenance maintenance must be carried out by fully trained personnel Note It is advisable to observe suitable ESD precautions when maintaining electronic assemblies Non User Adjustments Adjustments or alterations to the equipment may affect the performance such that safety and or international compliance standards may no longer be met Any such adjustments must therefore only be carried out by fully trained personnel Users This equipment is designed for use solely by engineers and competent operators skilled in the use of professional audio equipment Environment This p
38. he front of the RIO making it suitable for installation into equipment racks where space is limited The unit is cooled from front to back using temperature controlled low noise fans so space for ventilation must be provided behind the rack A standard 600mm rack provides adequate ventilation space RIOs can be fitted with one or two removable power supplies A single PSU unit has sufficient capacity to supply a fully fitted RIO thus full PSU redundancy can be achieved by fitting two units Below the power supplies is space for six plug in cards The uppermost slot is always fitted with the RIO Interface Card This card is fitted with four fibre MADI interface ports for connection to the Blackrock processor Note that although each MADI link has capacity for 64 channels at 48kHz the first link is limited to 62 audio channels because two channels are reserved for sync and status information the remaining three links can access all 64 channels of bi directional audio data The maximum I O capacity for a single RIO unit is therefore 254 audio channels The interface card is also equipped with 24 channels of general purpose opto isolated input and 24 outputs are available via relay closures Refer to page 35 for contact ratings A sync output connector is included which provides a feed of the system s Wordclock reference 1 0 Daughter Cards Below the interface card are five available slots into which a range of input output cards can be fitted
39. he only data link required between the Blackrock processor and the CIOOHDS console The recommended configuration is to use two separate data cables in parallel Single Blackrock Systems a Connect the two off 0 5m network cables supplied to the Blackrock rear panel as shown opposite b Connect the two off console network cables supplied as shown opposite Length will be as specified at time of order c Connect the Blackrock TCP IP port to the Ethernet network port of a suitable PC If using a direct connection then a network cable of the crossover type will be necessary If the connection is via a standard network switch or hub then standard pin pin cables can be used Refer to page 37 for further details of configuring the PC for file transfer Systems with Redundant Blackrock a Connect the two off 0 5m network cables supplied to both the master and redundant Blackrock rear panels as shown opposite b Connect the two off console network cables supplied to each Blackrock processor as shown opposite Length will be as specified at time of order c Connect the supplied Im SSL network cable between both Blackrock processors d Connect the TCP IP ports from both Blackrock processors to an Ethernet hub or switch not supplied The PC being used for project backup etc will need to be connected to the same network Alternatively If a PC is not being used or a hub switch is not available then the TCP IP ports of
40. iagram opposite shows the location of these connectors Script Tray The script tray is an 8 channel wide movable transparent panel which fits over a channel bay It has rollers fitted to allow it to move along the length of the desk The script tray does not require modifications to the console and can be added to existing consoles Loudspeaker Shelf A flat secure shelf is available for the positioning of loudspeakers monitors etc Each shelf is 400mm wide by 253mm deep A shelf is securely attached by locating under the front of the top trim and then screws are used to fix to the console s back panel TFT External Input This option adds an input switcher to any of the channel bay TFT screens so that it can then be switched to display the signal from an external XGA 1024x768 video input The switchover may be effected either by a GPI closure triggered from a free button or by one of the unused latching switches located on the meter panel see page 43 Because it is necessary to install additional hardware within the console frame when adding this option a maximum of three of the four channel screens on the 32 channel console can be modified LCD Phasescope The Centre Section of the console has space reserved specifically for an LCD phasescope surround monitor Three versions of phasescope are available to order RTW10830 which features 8 channels of digital and 8 channels of analogue input with loop through outputs the DK A
41. identical to the 1100 version apart from its designation number The Impedance of each input and output circuit however is now 75Q and unbalanced for correct matching to installations using co axial cabling A separate BNC interface panel is available as a cost option This panel is 2U high and is fitted with 64 chassis mounted BNC plugs 32 input and 32 output One metre length D25 D25 interconnecting looms are provided A 3m loom is available to order at additional cost These looms must not be extended as the signals are unbalanced doing so will give rise to errors in the data When assigning digital card output channels as insert sends the routing system will automatically assign the same input channel number as the corresponding return It is therefore necessary to physically wire outboard equipment so that circuit allocation follows this arrangement Page 33 CIOOHDS Installation Guide GP 1 0 RIO Interface Card IN 13 24 OUT 13 24 IN 1 12 OUT 1 12 CE 0000000000000 77 0 0 0000000000 FN KA 000000000000 KZ 000000000000 GPI Input Connectors GPI Output Connectors 25 way D type Male 25 way D type Female Page 34 Section 5 Installation Wiring GPI 1 0 The Interface card fitted to each RIO unit is equipped with 24 circuits of GPI I O Each input is opto isolated and is accessed via 25 pin D type male connectors Outputs are
42. is supplied with four MADI ports as standard but may be expanded to provide eight ports as shown opposite The RIO unit is always equipped with four ports Connections between the Blackrock and RIO units are made using industry standard multimode 50 micron duplex LC fibre cable assemblies Multimode fibre is suitable for cable runs of up to 550m Suitable fibre cable assemblies are widely available from cable suppliers Singlemode fibre multiplexers can be specified for the Blackrock and RIO as a cost option These will require matching singlemode connectors and cable assemblies Singlemode cable is suitable for distances of ub to 2km The first MADI connection between the Blackrock and any RIO will provide 62 channels of bi directional audio two channels are used to transfer sync and status information Subsequent connections added to the same RIO will extend the capacity by 64 channels for each lead A maximum of four RIO units can be connected to a Blackrock processor For additional security a redundant fibre link can be connected between the Blackrock nd the RIO The backup fibre cables should be connected to the port directly above the primary port and 5 2 and 6 etc RIO Sync Output The Sync connector fitted to the front of the RIO interface card provides an output of Wordclock at the system s clock rate RIO Ethernet The Ethernet connector on the RIO interface card is non functional so does not need to be conne
43. ms are available as an option for installations where the console is freestanding The console surface is connected to its processing rack using two standard Ethernet cables These cables provide all the data for control metering and touchscreen display information These cables are supplied with each system Cable sets are available in 10 15 20 25 50 and 100m standard lengths 100m is the maximum distance between the console and its computer rack Refer to Appendix A for weights and power consumption information Rack Mounting Equipment Blackrock and RIO All audio processing functions are provided by a separate 2U rack mounted computer unit referred to as the Blackrock system s DSP resource Madi interfacing and file handling is all contained within the Blackrock unit Connections made to the rear of the rack Systems may be specified to have processor redundancy for on air or critical operations These systems will feature a second Blackrock chassis unit so an additional 2U of rack space will be required All input and output for the CI00HDS is made using remote input output racks referred to as RIOs A RIO is 7U rack mounting unit with slots for up to five plug in I O cards Each RIO is connected to the Blackrock processor using industry standard fibre Madi cables A 19 equipment rack will almost certainly need to be provided into which the Blackrock and or RIO units can be mounted Note that when locati
44. nection Any mains powered item of SSL equipment that is supplied with a 3 core mains lead whether connectorised or not must always have the earth wire connected to the mains supply ground This is the safety earth and grounds the exposed metal parts of the racks and cases and should not be removed for any reason Mains Supply and Phases To ensure safe operation of this equipment connect only to an ac power source that contains a protective earthing PE conductor This equipment is designed for connection to single phase supplies with the neutral conductor at earth potential category TN or TT and is fitted with a protective fuse in the live conductor only This equipment is not designed for use with live and neutral connections reversed or where the neutral conductor is not at earth potential IT supplies This equipment should not be connected to a power system that switches open the return neutral lead when the return lead also functions as the protective earth PE All mains powered assemblies must be connected to the same mains phase In particular note that as PSU redundancy is standard the two input leads must NOT be connected across different phases of a 3 phase supply Mains cables will be coded with either of the following colour schemes 2 LIVE Brown Black NEUTRAL Blue White EARTH Yellow Green Green The ratings label which details the console power requirements is located adjacent to the mains inlet conne
45. ng remote RIO units that all connections are made to the front See page 10 for service clearance diagrams The SSL MORSE Router and remote Stageboxes may also be specified to form part of the CI00HDS system These are either 3U or 6U rack units Blackrock and RIO units must be supported on shelves fitted to the equipment rack and not solely by the rack ears Acoustic Isolation The Blackrock processor is fitted with cooling fans and is expected to be housed in a separate machine room Adequate noise isolation should exist between the machine room and control room recording areas The RIO chassis is fitted with low noise fans and requires a lower degree of noise isolation Noise figures for individual units are given in Appendix A Page 7 CIOOHDS Installation Guide Connector Panels and Power Supplies Mains Panel Connector panel 1 8 9 16 Master Section 17 24 25 32 Top Trim access Power Supplies Connector panels Refer to page 46 for console dimensions Page 8 Section 3 Pre Installation Information Air Conditioning Requirements Air conditioning will almost certainly be required for both the Machine and Control rooms in order to maintain the temperature and humidity to within the required levels Power dissipation figures for console control surface and equipment rack are listed in Appendix A Appen
46. o be required in front of and behind the rack into which the Blackrock processor is installed so that cards can easily be removed See the drawing on page 10 for minimum clearances Page 9 CIOOHDS Installation Guide Blackrock Processor Chassis side view Showing Clearances 85 429 DNS 4 11 9 00000000000000000000 Removable Clearance for cabling Front Panel RIO Chassis side view Showing Clearances 100 344 270 i i YO Card Clearance for air vent Front Dimensions in mm Page 10 Section 3 Pre Installation Information Technical Requirements Sync Source The Blackrock Processor requires a feed of sync in order to operate Video Wordclock AES3id can used as the sync reference The video sync requirement is 750 IV pk pk black and burst The standard can be either PAL 625 line 50Hz NTSC 525 line 59 94Hz or 60Hz Composite sync may also be used Tri level sync cannot be used Other studio peripherals digital recorders routers editors and picture recorders will also require a feed of video sync Depending on the studio configuration a suitable video distribution amplifier may also be required The Blackrock processor does not provide internal sync generation or distribution Power Connections Mains Input Voltage amp Current Both the console
47. od may need to be extended at additional cost Note that travel and subsistence costs are not normally included For further information please contact SSL s training department at support solid state logic com Warranty All systems normally include 13 months warranty from date of shipment This does not include consumable items such as magnetic media disks etc Further details may be found in SSL s Conditions of Trading printed on the reverse of all SSL invoices Page 6 Section 3 Pre Installation Information Physical Requirements Console Control Surface The console control surface consists of a single Master section usually called the Centre Section and channel bays containing 8 faders each Consoles can be specified to have from 24 to 64 channels so the size and weight will vary considerably dimensioned footprint drawing showing the channel layout for a specific console control surface can be provided by SSL s Project Engineering Department See page 46 for the drawing of a standard 32 channel footprint Consoles can be built with a split point at any 8 channel profile The console can then be separated at this point into smaller sections to simplify installation into client s premises split console will require additional commissioning time reassembly will be by SSL engineers The side panels of the console are flat to reduce the overall width and to simplify the location of adjoining furniture Contoured side ar
48. otect against the possible loss of a RIO fibre cable both of the MADI cables between the RIO the and Blackrock processor can be configured to have a redundant spare which will automatically become the backup for the primary fibre cables This configuration provides a maximum audio channel count of 126 between the RIO and Blackrock including the redundant links Dual RIO units If a second RIO rack is required for additional I O this can be accommodated without restricting the capacity of a first RIO Adding a second Mezzanine card to the Blackrock core will provide sufficient MADI ports for four ports to link to each RIO pictured If the Blackrock is fitted with a single Mezzanine card only two MADI ports will be available to connect to each RIO Redundant Blackrock Processor For mission critical reliability a second Blackrock processor can be used as a redundant spare and connected to a single RIO if that is all the audio I O that is required This will allow the console to continue in the unlikely event that the primary Blackrock processor is lost Note that the RIO must now connect to each Blackrock using only two MADI fibres thereby limiting the number of audio channels to 126 without redundant link or 62 channels with redundant link Redundant Blackrock Processor and Dual RIO units In this scenario the limited I O capacity of a system with Blackrock redundancy and one RIO can be expanded with a second RIO unit Two of each RIO s four
49. page 54 for the DL pinout RIO Digital 1 0 Card The digital I O card is available in two versions 1100 and 750 Both types provide 64 channels 32 AES EBU pairs of digital input and output The 1100 card provides balanced output signals whereas the 750 card is unbalanced for correct matching to coaxial cables Sample rate conversion is available on every input so the card can accept input rates from 32kHz to 96kHz The connectors are all D 25 type females and mating connectors can be supplied as a cost option A breakout panel is available for the 750 card This panel converts the I O card s D 25 connectors to chassis BNC plugs and can be ordered with Im or 3m interconnecting leads Do not attempt to extend the panel interface leads beyond the 3m maximum as doing so could increase the risk of data corruption Page 19 CIOOHDS Installation Guide 0 0 MORSE Router 00 00 5 8 1 1 888 888 588 888 8 888 888 888 99 3 888 888 88 888 8 888 8 888 1 88899 oC jo 00
50. rd and a second card ports 5 8 can be specified to provide access to up to 512 I O channels T The signal capacity of the first Madi link connected to any RIO is reduced to 62 as two channels are reserved for control and status information This restriction does not apply to subsequent links connected to the same RIO Page 15 VF CIOOHDS Installation Guide RIO Rack front view 00 LOCKED O DATA 3 ETE 5 RUNNING POWER ANALOGUE OUT IN 13 24 OUT 13 24 AES EBU IN 25 32 ANALOGUE IN Page 16 Section 4 System Components Remote I O Rack RIO All console audio input and output signals are provided by separate input output racks These racks are referred to as RIOs The RIO is a 7U high 344mm deep 19 rack unit Each RIO requires its own mains power supply and fibre optic cable connection to the Blackrock processor A maximum of four RIOs can be connected to each C100 system All plug in cards and connectors are accessed via t
51. re available for Microphone level input line level analogue I O AES MADI and SDI A 2nd redundant power supply can be fitted Stageboxes are connected to the router or console using one or two duplex optical MADI links The fibre links between the Blackrock and the MORSE router are available as multimode type only The morse fibre connector standard is duplex SC Blackrock to MORSE fibre leads are therefore LC SC duplex multimode The MORSE system is more fully described in a separate SSL document Morse Specification Guide part number 82565 Page 21 CIOOHDS Installation Guide Location of Console Bellypanel Connectors Connections to Blackrock Processor 2 USBoutl USB in 2 USB out 2 Net 5 O 0 b b 0 1 DI D2 D3 TB out XI Unused Digital Analogue Spare Spare Spare Spare Meters Meters Console In In ID Page 22 Section 4 System Components System Options External Keyboard There is an inbuilt software keyboard included in the C100 system this is accessed via the centre section touch screen Alternatively an external USB computer keyboard and or USB mouse trackball may be connected to the audio connector panel using the connectors provided USB and USB 2 The d
52. rface cards can be fitted Cards are available in different combinations of analogue and digital I O It is therefore important to discuss individual requirements with SSL s Project Engineering Department prior to order some combinations of I O may not be able to be accommodated due to limited connector availability The inputs to the meters are accessed via two 25 pin D type connectors mounted on the connector panel The analogue inputs use a male connector and the digital inputs use a female Cable connections to the meters and phasescope will need to be run between the RIO and the Console Both balanced analogue and 1100 digital cables may be necessary depending on configuration These cables are not supplied by SSL The signals used to feed the meters could be paralleled from the console main output busses or independent feeds from the appropriate output card Refer to pages 51 and 52 for the meter connector pinouts It is the responsibility of the facility to ensure that all cabling required to enable correct operation of the VU and phasescope meters is installed prior to the console being commissioned Page 4I CIOOHDS Installation Guide User Definable Macro Switches Macro switches momentary SS Macro hardwire switches latching O PSU1 PSU2 N 324 2 Mi e LE ERO C 1 O O Ke HD L Solid State Logic SOUND
53. rical and electronic equipment The separate collection and recycling of your waste equipment at the time of disposal will help to conserve natural resources and ensure that it is recycled in a manner that protects human health and the environment For more information about where you can drop off your waste equipment for recycling please contact your local city office your household waste disposal service or where you purchased the product Page 5 CIOOHDS Installation Guide Section 3 Pre Installation Information Physical installation of the console is normally carried out by a specialised transportation company In some cases this will have been arranged by the local SSL office in other cases by the facility Before the console is installed all building work should be completed and the environment MUST be clean otherwise the warranty will be rendered invalid Before commissioning can take place the following must be completed Air Conditioning installed tested blown through and working Lighting installed and tested Cable Trunking installed Wall and floor finishes completed Power Distribution installed and tested Cables installed and tested Monitor loudspeakers installed and working Other utilities telephone water etc available The cables that run between console and processor can be shipped in advance of the console in a separate kit the pre install kit These cables should be installed by the
54. roduct is a class A product intended to form an integrated component part of a professional audio recording mixing TV radio broadcast or similar studio wherein it will perform to specification providing that it is installed according to professional practice Electrical Safety Warning When installing or servicing any item of SSL equipment with power applied when cover panels are removed HAZARDOUS CONDITIONS CAN EXIST These hazards include High voltages High energy stored in capacitors High currents available from DC power busses Hot component surfaces Any metal jewellery watches bracelets neck chains and rings that could inadvertently come into contact with uninsulated parts should always be removed before reaching inside powered equipment Installation Instructions Voltage Selection and Fusing All CI00HDS systems use auto ranging power supplies These are designed to operate at input voltages the range 0 to 240VAC 10 so do not require setting to suit the local supply If where fitted it is ever necessary to replace a blown mains fuse then always use the correct rating and type of replacement If a correctly rated fuse continues to blow then a fault exists and the cause should be investigated or the unit returned to SSL for repair replacement as appropriate Details of mains settings and correct fuse ratings can be found in Appendix A of this manual Page 3 CIOOHDS Installation Guide Safety Earth Con
55. rossover type The computer used must have SSH terminal client installed PuTTY for example if using a PC Macintosh users can use The Terminal utility included with OSX The Blackrock does not support wireless networking Grounding A standard system should not require any additional grounding over and above that supplied by a correctly installed mains supply All rack unit chassis are permanently bonded to mains earth mains earth connection via the mains inlet must be provided If due to the quality of the mains wiring within an installation it is deemed necessary to improve upon the mains earthing a chassis ground connection point is provided as follows Console chassis ground can be accessed via a stud located on the mains power connector panel All audio connectors both analogue and digital have their screen pins connected directly to the chassis at the point of entry to comply with AES EBU EMC grounding standards Page 11
56. t Panel OOOO a o gt N 0000 O CIOOHDS Installation Guide This page is intentionally mostly blank Page 56 Appendix D Audio Interfacing Appendix D Audio Interfacing All analogue audio inputs and outputs are electronically balanced The screen pins are all directly connected to the chassis at the point of entry to comply with AES EBU grounding and EMC recommendations Balanced Circuits It is strongly recommended that balanced connections are used wherever possible using high quality screened cable The following diagram shows the recommended connection with both screens connected to the chassis Balanced Balanced 8 Both screens connected to chassis Recommended Chassis Chassis On some older items of equipment the screen connection may still be referenced to the circuit OV rather than the chassis In these cases it may be advantageous to disconnect the screen at this connection Note however that this practice will degrade the EMC performance Balanced Balanced One screen connected to chassis Chassis OV Connecting to Unbalanced Equipment Connecting to unbalanced equipment can be much more problematic It is quite likely that induced RF earth currents will become referenced to the audio 0 which will give rise to audible hum and buzz The recommend
57. udio MSD600C with 6 channels of digital input and the MSD600M which can accommodate varying input and output options by using plug in modules The RTW and the MSD600C units are provided in standard configurations The MSD600M meter can be adapted to suit specific applications so its installation options should be discussed with 55175 Project Engineering department Page 23 Console Mains Inlet Panel e Gf d ME l ATO CIOOHDS Installation Guide 9 Page 24 Section 5 Installation Wiring Section 5 Installation Wiring This section provides the information necessary to connect the system components Power Supply Connections a Connect both the console s IEC mains leads to a suitable mains supply outlet These leads are supplied unterminated to simplify connection to the facility s preferred distribution system For live transmissions work it is recommended that one of the power feeds should be from an uninterruptable source THE MAINS SAFETY EARTH MUST BE CONNECTED THE TWO POWER SOURCES MUST NOT BE FROM DIFFERENT PHASES OF A 3 PHASE SUPPLY The console is fitted with auto ranging power supplies which will accept mains voltages which range from 100 to 2
Download Pdf Manuals
Related Search
Related Contents
Facturation des travaux de traduction commandés par la PHIL 15D Manual de instalación WS Remote Solution DTS Logging Data User Guide D GB NL E S I P MHC-S9D Digitus DB-600103-010-W mobile phone cable Panasonic Workio DP 取扱説明書 メガオイルポンプ ご使用前に必ずご確認ください PRÉSENTATION NOUVEAUTÉ Copyright © All rights reserved.