1. 42 dBm 15 W peak for 2 us Semiconductor thermocouple 1 6 30 kHz 100 kHz 1 2 100 kHz 300 kHz 1 1 300 kHz 4 2 GHz Provided with sensor 0 5 at 25 C between 10 and 20 dBm Improves by a factor of 10 for each lower range Provided with sensor Uncertainty provided with sensor 0 01 Precision N type male 50 Q 87 mm long 33 5 mm dia 140 g 56912 900 t specifications involving APC 7 and type N connectors above 18 GHz are not traceable to national standards as these do not exist at present http www ifrinternational com Wa Counters amp Power Meters EMPL 3 Power Sensors 6910 Series Medium Power Thermocouple Power Sensors continued FREQUENCY RANGE 10 MHz 26 5 GHz 10 MHz 40 GHz 10 MHz 46 GHz 30 kHz 3 GHz POWER RANGE 30 dBm to 20 dBm 30 dBm to 20 dBm 30 dBm to 20 dBm 30 dBm to 20 dBm 1 uW to 100 mW 1 uW to 100 mW 1 uW to 100 mW 1 uW to 100 mW MAX RF INPUT 25 dBm 300 mW CW 25 dBm 300 mW CW 25 dBm 300 mW CW 25 dBm 300 mW CW 42 dBm 15 W peak for 2 us 42 dBm 15 W peak for 2 us 42 dBm 15 W peak for 2 us 42 dBm 15 W peak for 2 ms SENSING ELEMENT Semiconductor thermocouple Semiconductor thermocouple Semiconductor thermocouple Semiconductor thermocouple VSWR 10 MHz 40 MHz 1 58 10 MHz 40 MHz 1 58 10 MHz 40 MHz 1 4 30 kHz 100 kHz 40 MHz 100 MHz 1 15 40 MHz 100 MHz 1 15 40MHz 100 MHz 1 15 100 kHz 300 kHz 100 MHz 2 GHz 1 1 100 MHz 2 GHz 1 1 1
2. A ruggedized solution for microwave power and frequency measurements in the field HM Combined Frequency Counter and Power Meter in one unit HM Iwo models available 10 MHz to 20 GHz 10 MHz to 46 GHz WE Large easy to read screen allows simultaneous display of both power and frequency measurements W Built in DVM for AGC voltage measurements WE Designed for use in the field weighing only 4 9 kg 10 8 Ib and battery operated M Supported by the full range of IFR power sensors IFR s Counter Power Meter CPM is a portable combination of three instruments a Microwave Frequency Counter true Power Meter and Digital Voltmeter A compact instrument with internal rechargeable battery ruggedized case and carrying strap it can be used up a tower on a roof top or at a field site Digital microwave radios are commonly installed for network access to mobile radio cell sites and quick installation of business communications The CPM is the ideal instrument for installation and maintenance engineers working on these systems Designed for Field Use The CPM weighs 4 9 kg 10 8 Ib including battery which makes it ideal for taking up radio towers or carrying on to http www ifrinternational com CPM 20 46 Counter Power Meter iiit tei mi exposed roof top sites A supplied accessory pouch contains and protects all the required accessories The rechargeable battery gives three hours of continuous operation B
3. These stable and accurate power sensors operate at frequencies up to 46 GHz They are for use with the 6960B and 6970 Power Meters as well as the CPM 20 40 Counter Power Meter and the 6910 6920 amp 6930 series 6200B series Microwave Test Set High Measurement Accuracy High measurement accuracy over a wide frequency range is ensured by low input VSWR the result of innovative design Fully Interchangeable The sensors are fitted with precision connectors They have a multiway socket for cable connection to the Power Meter and are interchangeable Small and Lightweight The small size and light weight of these sensors makes them very adaptable for use anywhere without requiring additional mechanical support Rugged Construction Rugged mechanical construction makes 6910 series Medium Power Thermocouple Power Sensors FREQUENCY RANGE POWER RANGE 10 MHz 20 GHz 30 dBm to 20 dBm 1 uW to 100 mW MAX RF INPUT 25 dBm 300 mW CW 42 dBm 15 W peak for 2 us SENSING ELEMENT VSWR Semiconductor thermocouple 1 25 1 1 30 MHz 2GHz 1 18 2 GHz 16 GHz 1 28 16 GHz 18 GHz 1 4 typical LINEARITY FACTOR Provided with sensor Accuracy CALIBRATION FACTOR Provided with sensor Accuracy Resolution RF CONNECTOR SIZE amp WEIGHT ORDER CODES 0 01 Precision N type male 50 Q 56910 900 10 MHz 30 MHz 18 GHz 20 GHz T 0 5 at 25 C between 10 and 20 dBm Improves by a factor of 10 for
4. of 10 for each lower range Provided with sensor Uncertainty provided with sensor 0 01 Precision N type male 50 Q 93 mm long 33 5 mm dia 190g 56932 900 T2 92 mm connectors mate non destructively with 3 5 mm and SMA connectors ttt specifications involving 2 92 mm connectors above 40 GHz are not traceable to national standards as these do not exist at present FREQUENCY RANGE POWER RANGE MAX RF INPUT Sensing element VSWR LINEARITY FACTOR Accuracy CALIBRATION FACTOR Accuracy Resolution RF CONNECTOR SIZE amp WEIGHT ORDER CODES 6930 Option 002 Comprises standard 6930 plus calibrated precision 10 dB attenuator 10 MHz 18 GHz 5 dBm to 44 dBm 0 3 mW to 25W 45 dBm 30 W CW 60 dBm 1 kW peak for 2 us Semiconductor thermocouple 1 2 10 MHz 8 GHz 1 25 8 GHz 12 4 GHz 1 35 12 4 GHz 18 GHz Provided with sensor 2 to 6 between 35 and 44 dBm Improves by a factor of 10 for each lower range Provided with sensor Uncertainty provided with sensor 0 01 Precision N type male 50 Q 228 mm long 64 mm dia 533g 56930 002 6932 Option 002 Power Sensors 10 MHz 40 GHz 15 dBm to 30 dBm 30 uW to 1W 33 dBm 2 W CW 45 dBm 32 W peak for 2 us Semiconductor thermocouple 1 12 10 MHz 100 MHz 1 1 100 MHz 2 GHz 1 15 2 GHz 12 4 GHz 1 2 12 4 GHz 18 GHz 1 25 18 GHz 26 5 GHz 1 43 26 5 40 GHz vers 001 1 55 26 5 40 GHz vers 002 Provided with se
5. Storage Humidity Range Up to 93 RH at 40 C Shock and Vibration MIL T 28800 for class 3 Drop Test IEC 68 2 32 Overall Instrument Protection IEC 529 rating IP 523 EMC and Safety Conforms with the limits specified in the following standards Emissions EN55011 1991 AS NZS2064 1 2 Immunity CISPR11 EN50082 1 1992 AS NZS4252 1 Safety EN61010 1 UL3111 1 lEC801 2 1991 IEC801 3 1984 IEC801 4 1988 IEC 1010 1 CSA C22 2 No 1010 1 Versions and Accessories When ordering please quote the following ordering number information Ordering Number CPM 20 CPM 46 Option 001 41690 616 41700 788 43113 022 28541 213 43169 039 43138 663 23443 874 46882 335 54311 219 54311 134 54351 027 43113 022 54464 001 46880 084 56910 900 56911 900 56912 900 56913 900 56914 001 56914 002 56914 003 56919 900 56920 900 56923 900 56924 001 56924 002 56924 003 56930 900 56932 900 56934 001 56934 002 56934 003 56930 002 56932 002 Version 10 MHz to 20 GHz Counter Power Meter 10 MHz to 46 GHz Counter Power Meter Replaces DTCXO with TCXO Supplied with Accessory pouch Carrying strap Rechargable battery Universal AC adapter battery charger Power lead for charger Vehicle DC supply lead 1 5 m power sensor cable DVM BNC adapter Operating Manual Accessories 20 GHz standard counter cable 1 5 m SMA m to SMA m Adapter N m to SMA f 40 GHz counter cable
6. each lower range Uncertainty provided with sensor 87 mm long 33 5 mm dia 140g 10 MHz 20 GHz 30 dBm to 20 dBm 1 uW to 100 mW 25 dBm 300 mW CW 42 dBm 15 W peak for 2 us Semiconductor thermocouple 1 25 10 MHz 30 MHz 1 15 30 MHz 2 GHz 1 18 2 GHz 16 GHz 1 28 16 GHz 18 GHz 1 4 typical 18 GHz 20 GHz t Provided with sensor Provided with sensor Uncertainty provided with sensor 0 01 APC 7 50 Q 87 mm long 33 5 mm dia 140 g 56911 900 0 5 at 25 C between 10 and 20 dBm Improves by a factor of 10 for each lower range RF Power Sensors pr q ie pa wy a them ideal for both bench and field use Minimum down time is ensured by using a pre calibrated field replaceable RF sensing assembly Unit lifetime is enhanced by high overload capabilities Seventeen different sensors are currently available covering a range of frequencies from 30 kHz to 46 GHz Type N APC 7 MPC 3 5 and 2 92 mm connectors are available from 70 dBm 100 pW to 44 dBm 25 W A 75 Q sensor is also available For the 40 GHz sensors 6914 6924 and 6934 a waveguide 22 transformer is optionally available By ordering version 7 002 the transformer 54417 002 is supplied as well as a calibration table to give both accurate waveguide and coaxial measurements The calibration information is traceable to national standards 30 kHz 4 2 GHz 30 dBm to 20 dBm 1 uW to 100 mW 25 dBm 300 mW CW
7. 0 5 m 2 92 mm m to 2 92 mm m Spare battery Desktop battery charger Service Manual Power Sensors Standard 30 dBm to 20 dBm 10 MHz to 20 GHz Type N 10 MHz to 20 GHz APC 7 30 kHz to 4 2 GHz Type N 10 MHz to 26 5 GHz MPC 3 5 mm 10 MHz to 40 GHz 2 92 mm 10 MHz to 40 GHz 2 92 mm plus waveguide 22 coax transition and calibration table 10 MHz to 46 GHz 2 92 mm 75 Q 30 kHz to 3 GHz Type N Low power 65 dBm to 20 dBm 10 MHz to 20 GHz Type N 10 MHz to 26 5 GHz MPC 3 5 10 MHz to 40 GHz 2 92 mm 10 MHz to 40 GHz 2 92 mm plus waveguide 22 coax transition and calibration table 10 MHz to 46 GHz 2 92 mm High power 10 MHz to 18 GHz 15 to 35 dBm Type N 30 kHz to 4 2 GHz 15 to 35 dBm Type N 10 MHz to 40 GHz 15 to 30 dBm 2 92 mm 10 MHz to 40 GHz 15 to 30 dBm 2 92 mm plus waveguide 22 coax transition and calibration table 10 MHz to 46 GHz 15 to 30 dBm 2 92 mm 10 MHz to 18 GHz 5 to 44 dBm Type N 30 kHz to 4 2 GHz 5 to 44 dBm Type N 60dBm for 6923 and 6924 http www ifrinternational com A range of 17 power sensors available for use with 6200B series MTS CPM 6960B and 6970 power meters M Wide frequency coverage 30 kHz to 46 GHz WE Power levels from 70 dBm 100 pW to 44 dBm 25 W E 50 Q and 75 Q sensors Mi Low VSWR reduces measurement uncertainty WE Linearity correction data supplied E Field replaceable RF assembly WE High overload capability
8. 00 MHz 2 GHz 1 1 300 kHz 2 GHz 2 GHz 12 4 GHz 1 15 2 GHz 12 4 GHz 1 15 2 GHz 12 4 GHz 1 2 typical 2 GHz 3 GHz 12 4 GHz 18 GHz 1 21 2 4 GHz 18 GHz 1 43 12 4 GHz 33 GHz 18 GHz 26 5 GHz 1 43 18 40 GHz vers 001 3 6 40 GHz 46 GHzttt 1 55 26 5 40 GHz vers 002 LINEARITY FACTOR Provided with sensor Provided with sensor Provided with sensor Provided with sensor Accuracy 0 5 at 25 C between 10 0 5 at 25 C at 100 mW 0 5 at 25 C at 100 mW 0 5 at 25 C between 10 and 20 dBm Improves by a decreasing by 0 005 per mW decreasing by 0 005 per mW and 20 dBm Improves by a factor of 10 for each lower range factor of 10 for each lower range CALIBRATION FACTOR Provided with sensor Provided with sensor Provided with sensor Provided with sensor Accuracy Uncertainty provided with sensor Uncertainty provided with sensor Uncertainty provided with sensor Uncertainty provided with sensor Resolution 0 01 0 01 0 01 0 01 RF CONNECTOR MPC 3 5 mm male 50 Q MPC 2 92 mm male 50 QT MPC 2 92 mm male 50 QT Precision N type male 75 Q SIZE amp WEIGHT 80 mm long 33 5 mm dia 140g 88 5 mm long 33 5 mm dia 140g 88 5 mm long 33 5 mm dia 89 mm long 33 5 mm dia 140g 140g ORDER CODES 56913 900 56914 001 56914 003 56919 900 56914 002 includes waveguide 22 coax transition and cal table Supplied with Adapter part no 23443 822 for Adapter part no 23443 822 Adapter part no 23443 822 Adapter part no 23443 842 for connection b
9. atteries can be charged from either the supplied AC adapter or a vehicle supply Battery life is continuously monitored and the display shows the percentage life remaining As accessories a spare battery and desktop charger are available The display uses transflective LCD technology which has an integral backlight This means that it can easily be read both outdoors in direct sunlight and indoors in low light The user interface makes operation fast simple and reliable Measurements are swiftly configured connections are clearly marked and results are easy to read Accuracy Despite being lightweight and portable there is no compromise in accuracy The standard reference oscillator is a DTCXO digitally controlled temperature compensated crystal oscillator A DTCXO has no warm up time and is ready to make accurate measurements immediately after switch on saving both time and battery life Power measurement accuracy is guaranteed through the use of the standard IFR 6900 series of power sensors These sensors have excellent return loss specifications which minimize mismatch errors in power measurements Calibration and linearity factors unique to each sensor can also be entered into the CPM to ensure the best accuracy at all times An integral O dBm 50 MHz power reference is used for sensor calibration ensuring measurement accuracy and traceability to national standards Fully Featured Two versions of the CPM are ava
10. ensor 0 01 Precision N type male 50 Q 228 mm long 64 mm dia 533 g 56932 002 numbers 44991 008 44991 009 44991 010 44991 011 44991 012 44991 013 44991 014 44991 015 44991 224 44991 225 http www ifrinternational com Calibrated Front End Field Replacement Modules For 6910 Power Sensor For 6911 Power Sensor For 6912 Power Sensor For 6913 Power Sensor For 6919 Power Sensor For 6920 Power Sensor For 6930 Power Sensor For 6932 Power Sensor For 6914 Power Sensor For 6934 Power Sensor EMPL 5 Power Sensors IFR Americas Inc 10200 West York Street Wichita Kansas IFR Ltd Longacres House Norton Green Road Stevenage Herts 67215 8999 USA E mail info ifrsys com SG1 2BA United Kingdom E mail info ifrinternational co uk Tel 1 316 522 4981 Toll Free USA 1 800 835 2352 Fax 1 316 522 1360 Tel 44 0 1438 742200 Freephone UK 0800 282 388 Fax 44 0 1438 727601 As we are always seeking to improve our products the information in this document gives only a general indication of the product capacity performance and suitability none of which shall form part of any contract We reserve the right to make design changes without notice All trademarks are acknowledged Parent Company IFR Systems Inc IFR Ltd 1999 http WWW ifrinternational com Part no 46891 065 Revision A
11. etween 6913 and for connection between 6914 for connection between 6914 connection between 6919 and 0 dBm Power Reference and 0 dBm Power Reference and 0 dBm Power Reference 0 dBm Power Reference t2 92 mm connectors mate non destructively with 3 5 mm and SMA connectors 6920 Series High Sensitivity Diode Sensors FREQUENCY RANGE 10 MHz 20 GHz 10 MHz 26 5 GHz 30 kHz 40 GHz 10 MHz 46 GHz POWER RANGE 70 dBm to 20 dBmt 70 dBm to 20 dBmt 70 dBm to 20 dBmt 70 dBm to 20 dBmt 0 1 nW to 10 uW 0 1 nW to 10 uW 0 1 nW to 10 uW 0 1 nW to 10 uW MAX RF INPUT 26 dBm 300 mW CW 26 dBm 300 mW CW 26 dBm 400 mW CW 26 dBm 300 mW CW 30 dBm 1 W peak for 2 us 30 dBm 1 W peak for 2 us 30 dBm 1 W peak for 2 us 30 dBm 1 W peak for 2 us SENSING ELEMENT Shottky barrier diode Shottky barrier diode Shottky barrier diode Shottky barrier diode VSWR 1 4 1 2 10 MHz 40 MHz 1 4 10 MHz 40 MHz 1 58 10 MHz 40 MHz 1 4 1 2 10 MHz 40 MHz 1 2 40 MHz 10 GHz 40 MHz 100 MHz 1 15 40 MHz 100 MHz 1 15 40 MHz 100 MHz 1 35 10 GHz 18 GHz s 100 MHz 2 GHz 1 12 100 MHz 2 GHz 1 12 100 MHz 2 GHz 1 4 typ 18 GHz 20 GHztt 2 GHz 8 GHz 1 33 2 GHz 18 GHz 1 33 2 GHz 18 GHz 8 GHz 18 GHz 1 51 8 GHz 33 GHz 15 18 GHz 33 GHz 18 GHz 26 5 GHz 1 95 26 5 40 GHz vers 001 1 95 33 GHz 40 GHz 1 97 26 5 40 GHz vers 002 3 6 40 GHz 46 GHzttt LINEARITY FACTOR Provided with sensor Provided with sensor Provided with sensor P
12. ilable CPM 20 measures frequencies from 10 MHz to 20 GHz and CPM 46 from 10 MHz to 46 GHz through a single input Power sensors cover the frequency range 30 kHz to 46 GHz and when used with a CPM measure 60 dBm to 44 dBm 25 W The frequency counter has relative frequency and frequency offset modes for frequency drift and frequency conversion measurements A limits function enables frequency to be measured against a specification with pass fail annunciator in the display Resolution is user settable from 1 Hz to 1 MHz CPM is designed for radio link testing The power meter features pass fail limits dB rel power offset and duty cycle modes An analog peaking meter is displayed for tuning and adjusting power levels A built in DVM complements the frequency counter and power meter Radio M Counters amp Power Meters CPM 20 46 1 O 2 crm 20 46 CPM 20 46 links are often aligned by monitoring the receiver AGC voltage The DVM with its clear 10 mV resolution readout and analog peaking meter is ideally suited to this task Specification Frequency Measurement Frequency Range 10 MHz to 20 GHz 10 MHz to 46 GHz Sensitivity 10 MHz to 20 GHz 20 dBm typ below 20 MHz 20 GHz to 26 5 GHz 20 dBm 26 5 GHz to 40 GHz 15 dBm 40 GHz to 46 GHz 10 dBm Input Connector Precision Type N f CPM 20 Precision 2 92 mm f CPM 46 Input Impedance 50 Q Nominal Maximum Input 10 MHz to 46 GHz 10 dBm ty
13. nsor 1 to 5 between 25 and 30 dBm less on other ranges Provided with sensor Uncertainty provided with sensor 0 01 MPC 2 92 mm male 50 Qt 87 mm long 33 5 mm dia 150g 56934 001 56934 002 includes waveguide 22 coax transition and calibration table Adapter part no 23443 822 for connection between 6934 and 0 dBm Power Reference Ordering 10 MHz 46 GHz 15 dBm to 30 dBm 30 uW to 1 W 33 dBm 2W CW 45 dBm 32 W peak for 2 us Semiconductor thermocouple 1 12 10 MHz 100 MHz 1 1 100 MHz 2 GHz 1 15 2 GHz 12 4 GHz 1 2 12 4 GHz 18 GHz 1 25 18 GHz 26 5 GHz 1 43 26 5 GHz 40 GHz 2 3 40 GHz 46 GHzttt Provided with sensor 1 to 5 between 25 and 30 dBm less on other ranges op ap od pa ap A o 09 T aD Provided with sensor Uncertainty provided with sensor 0 01 MPC 2 92 mm male 50 Qt 87 mm long 33 5 mm dia 150g 56934 003 Adapter part no 23443 822 for connection between 6934 and 0 dBm Power Reference Power Sensor Pre Comprises standard 6932 plus calibrated precision 10 dB attenuator 30 kHz 4 2 GHz 5 dBm to 44 dBm 0 3 mW to 25W 45 dBm 30 W CW 60 dBm 1 kW peak for 2 us Semiconductor thermocouple 1 2 30 kHz 4 2 GHz Provided with sensor 2 to 6 between 35 and 44 dBm Improves by a factor of 10 for each lower range Provided with sensor Uncertainty provided with s
14. on 4 digits wa Units dBm dBW pW nW uW mW W kW Features Limit checking Duty cycle dB Relative Power offset Analog Meter Correction Linearity Factor Calibration Factor Auto Calibration Ability to calibrate against a O dBm 1 mW 50 MHz power reference Auto Zero Removes DC offset from gain stages and power sensor Noise Floor after Auto Zero 6910 series lt 30 dBm 6920 series lt 65 dBm 6930 series lt 15 dBm Power Reference Frequency 50 MHz 0 10 MHz Power Level O dBm 1 mW Uncertainty 0 7 traceable to National Standards Accuracy 1 2 worst case for one year Output Connector N f 50 Q Adapters are supplied with 75 Q 3 5 mm and 2 92 mm power sensors Digital Voltmeter Voltage Range O V to 10 V DC only protected to 40 V Accuracy 2 5 of reading Resolution 10 mV Connector 4 mm banana sockets Impedance 6 MQ in parallel with 100 pF ve terminal connected to chassis via 10 kQ resistor LCD 1 4 VGA transflective with backlight Terminal Interface Connector 9 pin D male RS 232 DTE compatible Power Requirements DC Input Vehicle Supply or AC Adapter 10 V to 28 V 32 VA max Rechargable Battery 3 hours continuous operation minimum Recharge Time lt 4 hours 285 mm width 130 mm height 210 mm depth 4 9 kg 10 8 Ib Environmental Operating Temperature Range O to 45 C Storage Temperature Range Excluding Battery 40 to 70 C
15. ower Reference and 0 dBm Power Reference Lower limit is 65 dBm 0 3 nW when used with 6970 amp 60 dBm when used the Counter Power Meter t Lower limit is 65dBm 0 3 nW when used with Counter Power Meter tt specifications involving type N connectors above 18 GHz are not traceable to national standards as these do not exist at present ttt specifications involving 2 92 mm connectors above 40 GHz are not traceable to national standards as these do not exist at present a MOVO http www ifrinternational com 6930 Series High Power Thermocouple Sensors FREQUENCY RANGE POWER RANGE MAX RF INPUT SENSING ELEMENT VSWR LINEARITY FACTOR Accuracy CALIBRATION FACTOR Accuracy Resolution RF CONNECTOR SIZE amp WEIGHT ORDER CODES Supplied with 10 MHz 18 GHz 15 dBm to 35 dBm 30 uW to 3 W 37 dBm 5 W CW 50 dBm 100 W peak for 2 us Semiconductor thermocouple 1 1 10 MHz 2 GHz 1 18 2 GHz 16 GHz 1 28 16 GHz 18 GHz Provided with sensor 1 to 5 between 25 and 35 dBm Improves by a factor of 10 for each lower range Provided with sensor Uncertainty provided with sensor 0 01 Precision N type male 50 Q 93 mm long 33 5 mm dia 190g 56930 900 30 kHz 4 2 GHz 15 dBm to 35 dBm 30 uW to 3W 37 dBm 5 W CW 50 dBm 100 W peak for 2 us Semiconductor thermocouple 1 1 30 kHz 4 2 GHz Provided with sensor 1 to 5 between 25 and 35 dBm Improves by a factor
16. p below 20 MHz Damage Level 27 dBm Resolution User selectable 1 Hz to 1 MHz Measurement Time 1 Hz Resolution gt 1 Hz Resolution CPM 20 CPM 46 a25 lt 250 ms FM Tolerance 20 MHz peak to peak for gt 1 kHz rate AM Tolerance Any index as long as minimum level does not fall below sensitivity at 20 kHz rate Amplitude Discrimination 20 dB for signals gt 400 MHz Accuracy 1 Hz Resolution Frequency standard error 25 Hz 10 MHz to 20 GHz Frequency standard error 50 Hz 20 GHz to 46 GHz 10 MHz Frequency Standard Features Limit checking Relative frequency Frequency offset Frequency hold Temperature Stability DTCXO standard Better than 5 in 108 O to 50 C TCXO option 001 Better than 1 in 10 O to 50 C Ageing DTCXO standard 0 3 ppm year TCXO option 001 1ppm year External Frequency Standard Input 10 MHz 0 7 to 5 V p p sine or square wave into 1 kQ nominal AC coupled BNC female Power Measurement Frequency Range Sensor Dependent 30 kHz to 46 GHz Power Range Sensor Dependent 65 dBm 0 31 nW to 44 dBm 25 W Power Sensors Supported 6910 series 30 dBm to 20 dBm 6920 series 65 dBm to 20 dBm 6930 series 15 dBm to 35 dBm 6930 series opt 2 5 dBm to 44 dBm Power Accuracy After calibration using O dBm power reference 0 2 dB Measuring a signal in the centre of the power sensor dynamic range from a source with return loss better than 14 dB Resoluti
17. rovided with sensor Accuracy 1 at 25 C between 30 1 at 25 C between 30 and 1 at 25 C between 30 and 1 at 25 C between 30 and 20 dBm Improves by a 20 dBm Improves by a factor of 20 dBm at 23 C and 20 dBm at 23 C factor of 10 for each lower range 10 for each lower range CALIBRATION FACTOR Provided with sensor Provided with sensor Provided with sensor Provided with sensor Accuracy Uncertainty provided with sensor Uncertainty provided with sensor Uncertainty provided with sensor Uncertainty provided with sensor Resolution 0 01 0 01 0 01 0 01 RF CONNECTOR Precision N type male 50 Q MPC 3 5 mm male 50 Q MPC 2 92 mm male 50 Qt MPC 2 92 mm male 50 Qt SIZE amp WEIGHT 104 mm long 33 5 mm dia 87 mm long 33 5 mm dia 88 5 mm long 33 5 mm dia 88 5 mm long 33 5 mm dia 180 g 180 g 150g 150g ORDER CODES 56920 900 56923 900 56924 001 56924 003 56924 002 includes waveguide 22 coax transition and calibration table Supplied with Precision Attenuator part no Precision Attenuator part no Precision Attenuator part no Precision Attenuator part no 23448 873 23448 873 23448 873 23448 873 30 dB 0 05 dB at 30 dB 0 05 dB at 30 dB 0 05 dB at 30 dB 0 05 dB at 50 MHz at 25 C 50 MHz at 25 C 50 MHz at 25 C 50 MHz at 5 C Adapter part no 23443 822 for Adapter part no 23443 822 for Adapter part no 23443 822 connection between 6923 and connection between 6924 and for connection between 6924 0 dBm Power Reference 0 dBm P
Download Pdf Manuals
Related Search
Related Contents
ARAMS Market Portal Application User Guide June 2015 Nov 2013 Samsung GT-E2210L manual do usuário(TIM) obdtoolshop.co.uk - OBD Diagnostic Tools eShop Samsung 24" tippklassi LED monitor koos eriti õhukeste servadega Kasutusjuhend Shure SM81-LC microphone Minox Bl 8x52BR Consignes de sécurité importantes Guía de Inicio Rápido Nikon D3300 + 18-55 VR II + SD 4GB Copyright © All rights reserved.