Gree Cozy GWH18-24-28k Dreds Installation

image

Contents

1. 2 The drain hose should be bound at the bottom 9 Hang the Indoor Unit 1 Put the bound pipes in the wall pipe and then make them pass through the wall hole 2 Hang the indoor unit on the wall mounting frame 3 Stuff the gap between pipes and wall hole with sealing gum 4 Fix the wall pipe As show in Fig 16 5 Check if the indoor unit is installed firmly and closed to the wall As show in Fig 17 Indoor Outdoor Wall pipe Z Fig 16 Sealing gum Lower hook of wall mounting frame A Note Do not bend the drain hose too excessively in order to prevent blocking 47 8 6 Installation of Outdoor Unit 1 Fix the Support of Outdoor Unit select it according to the actual installation situation 1 Select installation location according to the house structure 2 Fix the support of outdoor unit on the selected location with expansion screws AN Note 1 Take sufficient protective measures when installing the outdoor unit 2 Make sure the support can withstand at least four times the unit weight 3 The outdoor unit should be installed at least 3cm above the floor in order to install drain joint As show in Fig 18 4 For the unit with cooling capacity of 2300W 5000W 6 expansion screws are needed for the unit with cooling capacity of 6000W 8000W 8 expansion screws are needed for the unit with cooling capacity of 1O000W 16000W 10 expansion screws are needed Drain vent CE
2. 5 The place with sulfureted gas 6 Other places with special circumstances 2 Indoor Unit 1 There should be no obstruction near air inlet and air outlet 2 Select a location where the condensation water can be dispersed easily and won t affect other people 3 Select a location which is convenient to connect the outdoor unit and near the power socket 4 Select a location which is out of reach for children 5 The location should be able to withstand the weight of indoor unit and won t increase noise and vibration 6 The appliance must be installed 2 5m above floor 7 Don t install the indoor unit right above the electric appliance 8 The appliance shall not be installed in the laundry 3 Outdoor Unit 1 Select a location where the noise and outflow air emitted by the outdoor unit will not affect neighborhood 2 The location should be well ventilated and dry in which the outdoor unit won t be exposed directly to sunlight or strong wind 3 The location should be able to withstand the weight of outdoor unit 4 Make sure that the installation follows the requirement of installation dimension diagram 5 Select a location which is out of reach for children and far away from animals or plants If it is unavoidable please add fence for safety purpose Installation and Maintenance 9 8 4 Electric Connection Requirement 1 Safety Precaution 1 Must follow the electric safety regulations when insta
3. drill head electric drill 6 Torque wrench open end wrench inner hexagon spanner ps 9 Pressure meter 12 Soldering appliance refrigerant container Installation and Maintenance 90edsS 43 Drainage pipe EE OE RB RER SRRRERRERRROE Space to the wall Gane sea JOO au 0 BoedS 8 1 Installation Dimension Diagram 8 Installation Service Manual Space to the wall Installation and Maintenance Service Manual Installation Procedures Start installation Preparation before installation Read the requirements select installation Prepare tools for electric connection location Select indoor unit Select outdoor unit installation location installation location Install the support of outdoor unit select it according to the actual situation Install wall mounting frame drill wall holes Connect pipes of indoor Fix outdoor unit unit and drainage pipe Connect wires of indoor unit Install drai
4. mounted frame As show in Fig 1 Wall Wall Mark in the middle of it 7 Level meter S Nspace Space Yo the to the wa wall som above 150mm 150m N E Left 55 70mm Fig 1 Rear piping hole Right 2 Open a piping hole with the diameter of 55 70mm on the selected outlet pipe position In order to drain smoothly slant the piping hole on the wall slightly downward to the outdoor side with the gradient of 5 10 As show in Fig 2 Outdoor Indoor 055 070mm Fig 2 A Note 1 Pay attention to dust prevention and take relevant safety measures when opening the hole 2 The plastic expansion particles are not provided and should be bought locally 4 Outlet Pipe 1 The pipe can be led out in the direction of right rear right left or rear left As show in Fig 3 2 When selecting leading out the pipe from left or right please cut off the corresponding hole on the bottom case As show in Fig 4 L i S Za Left Rear left Fig 3 Left Right Cut off the hole Fig 4 46 55 70mm Rear piping hole Service Manual 5 Connect the Pipe of Indoor Unit 1 Aim the pipe joint at the corresponding bellmouth As show in Fig 5 2 Pretightening the union nut with hand 3 Adjust the torque force by referring to the following sheet Place the open end wrench on the pipe joint and place the torque wrench on the union nut Tighten the
5. the liquid valve and gas valve and the nut of refrigerant charging vent 2 Connect the charging hose of piezometer to the refrigerant charging vent of gas valve and then connect the other charging hose to the vacuum pump 3 Open the piezometer completely and operate for 10 15min to check if the pressure of piezometer remains in 0 1MPa 4 Close the vacuum pump and maintain this status for 1 2min to check if the pressure of piezometer remains in 0 1MPa If the pressure decreases there may be leakage 5 Remove the piezometer open the valve core of liquid valve and gas valve completely with inner hexagon spanner 6 Tighten the screw caps of valves and refrigerant charging vent As show in Fig 28 Liquid valve Gas valve K valv FE Q Refrigerant charging QA Valve cap vent K YST 1 SD Nut of refrigerant en 4 WA Piezometer o O i O MG D P Charging vent one Ltr 7 Vacuum pump Inner hexagon Fig 28 2 Leakage Detection 1 With leakage detector Check if there is leakage with leakage detector 2 With soap water If leakage detector is not available please use soap water for leakage detection Apply soap water at the suspected position and keep the soap water for more than 3min If there are air bubbles coming out of this position there s a leakage Installation and Maintenance 9 8 8 Check after Installation and Test Operation 1 Check after Installation Check ac
6. union nut with torque wrench As show in Fig 6 4 Wrap the indoor pipe and joint of connection pipe with insulating pipe and then wrap it with tape As show in Fig 7 Open end wrench Union nut 1 Pipe joint Union nut Pipe Torque wrench Pipe z a ae Fig 5 Indoor pipe Fig 6 Ww Insulating pipe Fig 7 Refer to the following table for wrench moment of force Hex nut diameter mm Tightening torque N m 15220 9 52 30 40 45 55 60 65 70 75 6 Install Drain Hose 1 Connect the drain hose to the outlet pipe of indoor unit As show in Fig 8 2 Bind the joint with tape As show in Fig 9 Drain hose Outlet pipe tape Fig 9 Outlet pipe AN Note 1 Add insulating pipe in the indoor drain hose in order to prevent condensation 2 The plastic expansion particles are not provided As show in Fig 10 Drain hose eam cat m Insulating pipe Fig 10 9 Installation and Maintenance Service Manual 7 Connect Wire of Indoor Unit 1 Open the panel remove the screw on the wiring cover and then take down the cover As show in Fig 11 Panel Screw Fig 11 Wiring cover 2 Make the power connection wire go through the cable cross hole at the back of indoor unit and then pull it out from the front side As show in Fig 12 3 Remove the wire clip connect the power connection wire to the wiring terminal a
7. C Chassis rain ese Outdoor drain joirt At least 3cm above the floor oe Fig 18 Fig 19 2 Install Drain Joint Only for Cooling and Heating Unit 1 Connect the outdoor drain joint into the hole on the chassis 2 Connect the drain hose into the drain vent As show in Fig 19 3 Fix Outdoor Unit 1 Place the outdoor unit on the support 2 Fix the foot holes of outdoor unit with bolts As show in Fig 20 Foot holes Handle Screw Foot holes Fig 20 Fig 21 4 Connect Indoor and Outdoor Pipes 1 Remove the screw on the right handle of outdoor unit and then remove the handle As show in Fig 21 2 Remove the screw cap of valve and aim the pipe joint at the bellmouth of pipe As show in Fig 22 gas valve Fig 22 3 Pretightening the union nut with hand 4 Tighten the union nut with torque wrench 48 Service Manual Refer to the following table for wrench moment of force Hex nut diameter mm Tightening torque N m 15 20 9 52 30 40 45 55 60 65 70 75 5 Connect Outdoor Electric Wire 1 Remove the wire clip connect the power connection wire and power cord to the wiring terminal according to the color fix them with screws As show in Fig 23 F boelie I Ilow blue black yellow green epee brown blue I brown Indoor Unit Note The wiring connect is for reference only please refer to t
8. Service Manual Part Installation and Maintenance 7 Notes for Installation and Maintenance Safety Precautions Important Please read the safety precautions carefully before installation and maintenance The following contents are very important for installation and maintenance Please follow the instructions below e The installation or maintenance must accord with the instructions eComply with all national electrical codes and local electrical codes ePay attention to the warnings and cautions in this manual eAll installation and maintenance shall be performed by distributor or qualified person eAll electric work must be performed by a licensed technician according to local regulations and the instructions given in this manual eBe caution during installation and maintenance Prohibit incorrect operation to prevent electric shock casualty and other accidents A N Warnings Electrical Safety Precautions 1 Cut off the power supply of air conditioner before checking and maintenance 2 The air condition must apply specialized circuit and prohibit share the same circuit with other appliances 3 The air conditioner should be installed in suitable location and ensure the power plug is touchable 4 Make sure each wiring terminal is connected firmly during installation and maintenance 5 Have the unit adequately grounded The grounding wire can t be used for other purposes 6 Must apply protective acce
9. are the unit should not be carried by only one person if it is more than 20kg 3 When installing the indoor unit and outdoor unit a suffi cient fixing bolt must be installed make sure the installation support is firm 4 Ware safety belt if the height of working is above 2m 5 Use equipped components or appointed components dur ing installation 6 Make sure no foreign objects are left in the unit after fin ishing installation Refrigerant Safety Precautions 1 Avoid contact between refrigerant and fire as it generates poisonous gas Prohibit prolong the connection pipe by welding 2 Apply specified refrigerant only Never have it mixed with any other refrigerant Never have air remain in the refrigerant line as it may lead to rupture or other hazards 3 Make sure no refrigerant gas is leaking out when installation is completed 4 If there is refrigerant leakage please take sufficient measure to minimize the density of refrigerant 5 Never touch the refrigerant piping or compressor without wearing glove to avoid scald or frostbite Improper installation may lead to fire hazard explosion electric shock or injury 41 42 Service Manual Main Tools for Installation and Maintenance 1 Level meter measuring tape 4 Electroprobe 7 Electronic leakage detector 10 Pipe pliers pipe cutter 2 Screw driver 5 Universal meter 8 Vacuum pump 11 Pipe expander pipe bender 3 Impact drill
10. ccording to the color tighten the screw and then fix the power connection wire with wire clip As show in Fig 13 blue black brown yellow Connect to outdoor unit Wiring board Fig 13 4 Put wiring cover back and then tighten the screw 5 Close the panel AN Note 1 All wires of indoor unit and outdoor unit should be connected by a professional 2 If the length of power connection wire is insufficient please contact the supplier for a new one Avoid extending the wire by yourself 3 For the air conditioner with plug the plug should be reachable after finishing installation 4 For the air conditioner without plug an air switch must be installed in the line The air switch should be all pole parting and the contact parting distance should be more than 3mm Installation and Maintenance 9 8 Bind up Pipe 1 Bind up the connection pipe power cord and drain hose with the band As show in Fig 14 2 Reserve a certain length of drain hose and power cord for installation when binding them When binding to a certain degree separate the indoor power and then separate the drain hose As show in Fig 15 3 Bind them evenly 4 The liquid pipe and gas pipe should be bound separately at the end Indoor and outdoor power cord Fig 14 Drain hose Connection pipe Band Fig 15 Indoor power cord AN Note 1 The power cord and control wire can t be crossed or winding
11. cording to the following requirement after finishing installation installed firmly emit noise It may cause insufficient cooling refrigerant leakage test heating capacity pipeline sufficient water dripping Is water drained well water dripping Is the voltage of power supply according to the It may cause malfunction or voltage marked on the damage the parts nameplate a Is electric wiring and 5 It may cause malfunction or pipeline installed damage epas correctly Is th i tf a It may cause electric leakage securely Does the power cord It may cause malfunction or follow the specification damage the parts Is there any obstruction It may cause insufficient cooling in air inlet and air outlet heating The dust and sundries caused It may cause malfunction or 10 aan during installation are damaging the parts removed 1 The gas valve and liquid P ___ It may cause insufficient cooling 11 valve of connection pipe heating capacity are open completely 2 Test Operation 1 Preparation of test operation e The client approves the air conditioner installation e Specify the important notes for air conditioner to the client 2 Method of test operation e Put through the power press ON OFF button on the remote controller to start operation e Press MODE button to select AUTO COOL DRY FAN and HEAT to check whether the operation is normal or not e f the ambient temperatu
12. he actual one 2 Fix the power connection wire and power cord with wire clip AN Note 1 After tightening the screw pull the power cord slightly to check if it is firm 2 Never cut the power connection wire to prolong or shorten the distance 6 Neaten the Pipes 1 The pipes should be placed along the wall bent reasonably and hidden possibly Min semidiameter of bending the pipe is 10cm 2 If the outdoor unit is higher than the wall hole you must set a U shaped curve in the pipe before pipe goes into the room in order to prevent rain from getting into the room As show in Fig 24 The drain hos xX can t raise upwards Fig 25 Fig 24 UO D 5 gt O 7 D A Note 1 The through wall height of drain hose shouldn t be higher than the outlet pipe hole of indoor unit As show in Fig 25 2 Slant the drain hose slightly downwards The drain hose can t be curved raised and fluctuant etc As show in Fig 26 e Installation and Maintenance Service Manual 3 The water outlet can t be placed in water in order to drain smoothly As show in Fig 27 VA ae Se x xX The drain hose can t be fluctuant wl D O G Cor xX The drain hose The water outlet can t be placed gt f can t be fluctuant in water The water outlet can t be fluctuant Fig 27 Fig 26 8 Vacuum Pumping and Leak Detection 1 Use Vacuum Pump 1 Remove the valve caps on
13. lling the unit 2 According to the local safety regulations use qualified power supply circuit and air switch 3 Make sure the power supply matches with the requirement of air conditioner Unstable power supply or incorrect wiring may result in electric shock fire hazard or malfunction Please install proper power supply cables before using the air conditioner Air switch capacity 18 24K 4 Properly connect the live wire neutral wire and grounding wire of power socket 5 Be sure to cut off the power supply before proceeding any work related to electricity and safety 6 Do not put through the power before finishing installation 7 For appliances with type Y attachment the instructions shall contain the substance of thefollowing If the supply cord is damaged it must be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid a hazard 8 The temperature of refrigerant circuit will be high please keep the interconnection cable away from the copper tube 2 Grounding Requirement 1 The air conditioner is first class electric appliance It must be properly grounding with specialized grounding device by a professional Please make sure it is always grounded effectively otherwise it may cause electric shock 2 The yellow green wire in air conditioner is grounding wire which can t be used for other purposes 3 The grounding resistance should comply with national electric safe
14. nage joint of outdoor unit only for cooling and heating unit Bind up pipes and hang the indoor unit Make the bound pipes pass through the wall hole and then connect outdoor unit Connect pipes of outdoor unit Connect wires of outdoor unit Neaten the pipes Vacuum pumping and leakage detection Check after installation and test operation Finish installation Note this flow is only for reference please find the more detailed installation steps in this section 44 9 Installation and Maintenance Service Manual 8 2 Installation Parts Checking Indoor unit 8 Sealinggum Outdoor unit 9 Wrapping tape Comecon nipe 10 Suppor of outdoor unit Wall mounting Drainage plug cooling frame and heating unit Connecting Owner s manual cable power cord remote controller Wall pipe a AN Note 1 Please contact the local agent for installation 2 Don t use unqualified power cord 8 3 Selection of Installation Location 1 Basic Requirement Installing the unit in the following places may cause malfunction If it is unavoidable please consult the local dealer 1 The place with strong heat sources vapors flammable or explosive gas or volatile objects spread in the air 2 The place with high frequency devices such as welding machine medical equipment 3 The place near coast area 4 The place with oil or fumes in the air
15. re is lower than 16 C the air conditioner can t start cooling 49
16. ssories such as protective boards cable cross loop and wire clip 7 The live wire neutral wire and grounding wire of power supply must be corresponding to the live wire neutral wire and grounding wire of the air conditioner 8 The power cord and power connection wires can t be pressed by hard objects 9 If power cord or connection wire is broken it must be replaced by a qualified person Installation and Maintenance D 10 If the power cord or connection wire is not long enough please get the specialized power cord or connection wire from the manufacture or distributor Prohibit prolong the wire by yourself 11 For the air conditioner without plug an air switch must be installed in the circuit The air switch should be all pole parting and the contact parting distance should be more than 3mm 12 Make sure all wires and pipes are connected properly and the valves are opened before energizing 13 Check if there is electric leakage on the unit body If yes please eliminate the electric leakage 14 Replace the fuse with a new one of the same specification if it is burnt down don t replace it with a cooper wire or conducting wire 15 If the unit is to be installed in a humid place the circuit breaker must be installed Installation Safety Precautions 1 Select the installation location according to the require ment of this manual See the requirements in installation part 2 Handle unit transportation with c
17. ty regulations 4 The appliance must be positioned so that the plug is accessible 5 An all pole disconnection switch having a contact separation of at least 3mm in all poles should be connected in fixed wiring 6 Including an air switch with suitable capacity please note the following table Air switch should be included magnet buckle and heating buckle function it can protect the circuit short and overload Caution please do not use the fuse only for protect the circuit 8 5 Installation of Indoor Unit 1 Choosing Installation location Recommend the installation location to the client and then confirm it with the client 2 Install Wall mounting Frame 1 Hang the wall mounting frame on the wall adjust it in horizontal position with the level meter and then point out the screw fixing holes on the wall 2 Drill the screw fixing holes on the wall with impact drill the specification of drill head should be the same as the plastic expansion particle and then fill the plastic expansion particles 45 in the holes 3 Fix the wall mounting frame on the wall with tapping screws ST4 2X25TA and then check if the frame is firmly installed by pulling the frame If the plastic expansion particle is loose please drill another fixing hole nearby 3 Install Wall mounting Frame 1 Choose the position of piping hole according to the direction of outlet pipe The position of piping hole should be a little lower than the wall