Home

Service Manual - Heritage Parts

image

Contents

1. 9 Delfield DIFFERENTIAL Na CUT IN 346 T KNOB CONTROLLED lt x For customer service call 800 733 8829 800 773 8821 Fax 989 773 3210 www delfield com 7 F18 Series Service and Installation Manual Condensing Unit Assembly 1 5 HORSE POWER KEY DELFIELD See below for receiver tank part Used F18WC39 47 52 amp 60 MEDIUM TECUMSEH PART COND PART 3526747 AEA9415ZXAEC2A540 2 DESCRIPTION 1 5 H P med condensing unit 3526762 AE570AT 907 J7 compressor 8200EMBJ30 relay start 85PS110C76 capacitor 8300MRTN96 overload protector 810M006B45 50837 coil condenser motor fan condenser ch gt 51561 blade fan 51080 receiver tank Refrigerant charges gas refrigerant 404A 16 07 For customer service call 800 733 8829 800 773 8821 Fax 989 773 3210 www delfield com 1 4 HORSE POWER MEDIUM KEY 6 Condensing coil requires periodic cleaning Used On 185 39 52 amp 60 F18WC68 78 87 amp 95 F18MC39 52 amp 60 F18DC52 and F18RC52 DELFIELD TECUMSEH PART PART 3526745 AEA94227XAEC20462 2 DESCRIPTION 1 4 H P med condensing unit 3526768 AE590AT 900 J7 compressor 820RR12E72 relay start 85PS165C27 capacitor 8300MRTN28 overload protector 810M006B45 50837 coil condenser motor fan condenser 51561 blade fan 51080 receiver ta
2. NUMBER DOORS CU FT SQ FT HORSE POWER PHASE AMPS LOAD BTU TD Remote Freezer Base F18FR35 1 19 5 58 2 56 1 3 115 60 1 10 0 943 160 F18FR50 2 19 12 21 5 12 1 2 115 60 1 10 0 1471 160 F18FR58 1 19 amp 1 27 15 6 51 3 4 115 60 1 10 0 1844 160 F18FR66 2 27 17 79 7 9 3 4 115 60 1 10 0 2020 160 F18FR76 2 32 21 28 9 64 3 4 115 60 1 10 0 2437 160 MODEL OF STORAGE SHELF AREA VOLTS HERTZ BTU EVAP CAP NUMBER DOORS CU FT SQ FT HORSE POWER PHASE AMPS LOAD BTU TD Self Contained Freezer Base F18FC43 1 19 5 58 2 56 1 3 115 60 1 10 0 943 1558 F18FC62 2 19 12 21 5 12 1 2 115 60 1 12 0 1471 1776 F18FC70 1 19 amp 1 27 15 6 51 3 4 115 60 1 16 0 1647 2713 F18FC78 2 27 17 79 7 9 3 4 115 60 1 16 0 1824 2713 F18FC88 2 32 21 28 9 64 3 4 115 60 1 16 0 2045 2713 A 5 15P NEMA plug is used on F18FC43 amp F18FC62 A 5 20P NEMA plug is used on F18FC70 F18FC78 amp F18FC88 C Delfield For customer service call 800 733 8829 800 773 8821 Fax 989 773 3210 www delfield com 5 F18 Series Service and Installation Manual Installation Location Be sure the location chosen has a floor strong enough to support the total weight of the cabinet and contents A fully loaded 72 long model may weigh as much as 1500 pounds Reinforce the floor as necessary to provide for maximum loading It is very important to allow for proper air flow both inside and outside Avoid hot corner
3. 2 high mk7 000 aew 0040 000 aew 003k RF700110 000 333 0036 264 018 0036 264 018 0037 3234504 3234492 19 2 high mk7 000 aew 0041 000 aew 003l RF700111 000 333 0037 264 018 0038 3234504 3234492 5 6 7 8 9 10 11 Refrigerator Freezer Drawer front Drawer front Drawer front Drawer front Gasket Mullion Mullion assy assy top assy middle assy bottom 32 low profile 000 315 0033 000 315 003b 000 328 0033 na na na 1701197 27 low profile 000 315 0032 000 315 003a 000 328 0032 na na na 1701196 24 low profile 000 315 0031 000 315 0039 000 328 0031 na na na 1701195 19 low profile 000 315 0030 000 315 0038 000 328 0030 na na na 1701194 32 3 high mk7 000 315 0033 000 315 003b na 000 328 0037 000 328 0033 000 328 003b 1701197 27 3 high mk7 000 315 0032 000 315 003a na 000 328 0036 000 328 0032 000 328 003a 1701196 24 3 high mk7 000 315 0031 000 315 0039 na 000 328 0035 000 328 0031 000 328 0039 1701195 19 3 high mk7 000 315 0030 000 315 0038 na 000 328 0034 000 328 0030 000 328 0038 1701194 32 2 high mk7 000 315 0037 000 315 003f 000 327 0033 na na na 1701193 27 2 high mk7 000 315 0036 000 315 003e 000 327 0032 na na na 1701192 24 2 high mk7 000 315 0035 000 315 003d 000 327 0031 na na na 1701191 19 2 high mk7 000 315 0034 000 315 003c 000 327 0030 na na na 1701190 Complete cartridge assembly includes cartridge drawer boxes drawer fronts and mullion 264 018 0038 Divider bar can also be used in all drawer boxes for 1 6 size pan applications
4. C Delfield For customer service call 800 733 8829 800 773 8821 Fax 989 773 3210 www delfield com 1 3 F18 Series Service and Installation Manual Door Assembly Low Profile DELFIELD KEY PART DESCRIPTION XMK00005 complete door assy 19 18 75 x 15 72 XMK00006 complete door assy 24 23 75 x 15 72 XMK00007 complete door assy 27 26 75 x 15 72 1701187 gasket door 19 1701188 gasket door 24 1701189 gasket door 27 handle snap in 7 not replaceable 3234214 hinge door top LH bottom RH 3234218 hinge door top RH bottom LH 3234391 hinge door L shaped 9321107 bushing nylon hinge pin Used on F18SC F18SR F18MC amp F18MR NOTE Indicate if door is left or right hinged when ordering Cc 14 For customer service call 800 733 8829 800 773 8821 Fax 989 773 3210 www delfield com Delfield F18 Series Service and Installation Manual Door Assembly Mark 7 DELFIELD PART DESCRIPTION XMK00001 complete door assy 19 18 75 x 25 72 XMK00002 complee door assy 24 23 75 x 25 72 XMK00003 complete door assy 27 26 75 x 25 72 XMK00004 complete door assy 32 31 75 x 25 72 1701183 gasket door 19 1701184 gasket door 24 1701185 gasket door 27 1701186 gasket door 32 3234255 handle snap in 7 3234072 hinge door top LH bottom RH 3234073 hinge door top RH bottom LH 3234391 hinge door L shaped 9321107 b
5. Door Assembly XMK00109 Evaporator Assembly XMK00120 Louver Assembly 2183347 Cord Plug Assembly 3526731 Condensing Unit 3526752 Compressor 3977983 32 Wire Shelf F18RC91 000 402 0041 10 pan hinged removable cover 000 402 0045 12 pan hinged removable cover XMK00003 27 Door Assembly XMK00108 Evaporator Assembly XMK00109 Evaporator Assembly XMK00120 Louver Assembly 2183347 Cord Plug Assembly 3526731 Condensing Unit 3526753 Compressor 3978014 27 Wire Shelf F18RR SERIES STANDARD PARTS XMK00109 Evaporator Coil Assembly 1701000 Cutting board pin 2190154 Rocker switch 3234266 Right end pan cover hinge 3234282 Left end pan cover hinge 3234290 Plastic plug shelf support 3234292 Double pan cover hinge 3234645 Leg 3516103 Solenoid coil spade term 3516102 Solenoid valve 3516135 Hanging 4 thermometer 9321040 Stud spot 9321041 Acorn Nut for Pan cover hinge 9321132 Long stud dog point 9321374 Salad pan cover hinge pin ADDITIONAL PARTS F18RR44 SERIES 000 402 0041 Removable 10 pan hinged cover XMK00001 19 Door Assembly XMK00109 Evaporator Coil Assembly 2194201 Rail Thermostat 3977984 Wire shelf 19 F18RR52 SERIES 000 402 0045 Removable 12 pan hinged cover XMK00001 Door assembly 19 XMK00003 Door assembly 27 2194201 Rail Thermostat 3977984 Wire shelf 19 3978014 Wire shelf 27 F18RR60 SERIES 000 402 003X Removable 8 pan hinged cover SMK00776 Center divider bar XMK00003 27
6. 14 14 17 05 18 68 21 30 STORAGE CU FT SHELF AREA SQ FT 5 12 6 51 7 9 9 64 10 29 11 85 SHELF AREA SQ FT Self Contained Refrigerated Reduced Height Rail F18DC52 F18DC60 F18DC68 F18DC82 F18DC91 F18DC99 2 19 1 19 amp 1 27 2 27 2 32 1 19 amp 2 27 3 27 9 49 11 81 14 14 17 05 18 68 21 30 5 12 6 51 7 9 9 64 10 29 11 85 PANS 10 12 16 18 18 22 OF PANS 12 14 18 20 22 24 RECOMMENDED HORSE POWER 1 4 1 3 1 3 1 2 1 2 3 4 HORSE POWER 1 4 1 3 1 3 1 2 1 2 3 4 VOLTS HERTZ PHASE 115 60 1 115 60 1 115 60 1 115 60 1 115 60 1 115 60 1 VOLTS HERTZ PHASE 115 60 1 115 60 1 115 60 1 115 60 1 115 60 1 115 60 1 AMPS 3 0 3 0 5 0 5 0 5 0 5 0 AMPS 10 0 12 0 12 0 14 0 14 0 16 0 BTU DESIGN LOAD BASE RAIL 547 441 625 529 703 617 800 794 962 882 1032 970 BTU LOAD BASE RAIL 547 529 625 617 703 794 800 882 962 1058 1032 1147 EVAP CAP BTU TD 120 19 120 23 120 26 120 32 240 36 240 39 BTU SYSTEM CAP BASE RAIL 1903 1061 2314 1121 2314 1544 3097 1648 3807 1839 5286 2191 A 5 15 NEMA plug is used on F18RC52 F18RC60 amp F18RC68 5 20 NEMA plug is used on F18RC82 F18RC91 amp F18RC99 For customer service call 800 733 8829 800 773 8821 Fax 989 773 3210 www delfield com 9 Delfield F18 Series Service and Installation
7. 515 794 120 31 C SRA aaa O a VOLSHERIZ BTUDESI N SYSTEM CAP NUMBER DOORS CU FT PANS HORSE POWER PHASE AMPS BASE RAIL BASE RAIL Self Contained Refrigerated Mega Top Salad Tables F18MC39A 1 19 4 11 6 1 4 115 60 1 10 0 280 265 1903 925 F18MC39D 1 19 4 11 12 1 4 115 60 1 10 0 280 529 1903 1156 F18MC52A 2 19 6 94 6 1 4 115 60 1 10 0 444 265 1903 925 F18MC52D 2 19 6 94 12 1 4 115 60 1 10 0 444 529 1903 1156 F18MC52E 2 19 6 94 18 1 4 115 60 1 10 0 444 794 1903 1321 F18MC60A 1 19 amp 1 27 8 69 6 1 4 115 60 1 10 0 515 265 2314 864 F18MC60D 1 19 amp 1 27 8 69 12 1 4 115 60 1 10 0 515 529 2314 1141 FI8MC60E 1 19 amp 1 27 8 69 18 1 4 115 60 1 10 0 515 794 2314 1361 FI8MC60F 1 19 amp 1 27 8 69 24 1 4 115 60 1 10 0 515 1058 2314 1540 5 15 plug is used self contained units CZ Delfield For customer service call 800 733 8829 800 773 8821 Fax 989 773 3210 www delfield com 3 F18 Series Service and Installation Manual Specifications MODEL OF SHELFAREA OF RECOMMENDED VOLTS HERTZ BTU DESIGN EVAP CAP NUMBER DOORS SQ FT PANS HORSE POWER PHASE AMPS BASE RAIL BTU TD Remote Refrigerated Salad Top Tables F18SR31A 1 19 2 56 6 1 4 115 60 1 3 0 280 265 120 F18SR44A 2 19 5 12 6 1 4 115 60 1 3 0 491 441 120 F18SR44B 2 19 5 12 8 1 4 115 60 1 3 0 491 441 120 F18SR44C 2 19 5 12 10 1 4 115 60 1 3 0 491 441 120 F18S
8. 726 0351 800 737 0351 615 259 4100 FAX serves TN AL i 44792 Helm Plymouth MI 48170 880 828 4454 734 451 2043 734 451 3215 FAX serves MI IN WI OH 1177 Kamato Road Mississauga Ontario LAW1X4 800 427 6668 800 361 7745 FAX serves Canada 12 Performance Refrigeration Parts 9923 S W 178th St Vashon WA 98070 888 872 2465 206 463 1772 206 463 4431 FAX serves AK HI ID MT OR WA Delfield 980 S Isabella Rd Mt Pleasant MI 48804 0470 U S A 989 773 7981 or 800 733 8821 Fax 989 773 3210 www delfield com Delfield reserves the right to make changes in design or specifications prior notice 2001 the Delfield company All rights reserved Printed in the U S A DM18 10 02
9. Assembly 32 Shown dt E 7 2 gt p o A lt 2 High Mark 7 3 High Mark 7 Low Profile Delfield 9 F18 Series Service and Installation Manual Cartridge Style Drawer Systems See page 12 for blow out model diagram 1 2 3 4 Refrigerator Freezer Cartridge only Drawer box Divider Intermediate Intermediate Cartridge assy Cartridge assy fronts no mullions Bar s Left Track Right Track 32 lo profile 000 aew 0030 000 aew 003a RF700100 000 333 0034 264 018 0032 264 018 0034 3234504 3234492 27 lo profile 000 aew 0031 000 aew 003b RF700101 000 333 0035 264 018 0033 3234517 3234509 24 lo profile 000 aew 0032 000 aew 003c RF700102 000 333 0036 264 018 0036 264 018 0037 3234504 3234492 19 lo profile 000 aew 0033 000 aew 003d RF700103 000 333 0037 264 018 0038 3234504 3234492 32 3 high mk7 000 aew 0034 000 aew 003e RF700104 000 333 0034 264 018 0032 264 018 0034 3234504 3234492 27 3 high mk7 000 aew 0035 000 aew 003f RF700105 000 333 0035 264 018 0033 3234517 3234509 24 3 high mk7 000 aew 0036 000 aew 003g RF700106 000 333 0036 264 018 0036 264 018 0037 3234504 3234492 19 3 high mk7 000 aew 0037 000 aew 003h RF700107 000 333 0037 264 018 0038 3234504 3234492 32 2 high mk7 000 aew 0038 000 aew 003i RF700108 000 333 0034 264 018 0032 264 018 0034 3234504 3234492 27 2 high mk7 000 aew 0039 000 aew 003j RF700109 000 333 0035 264 018 0033 3234517 3234509 24
10. Compressor 3977983 Wire shelf 32 F18DC91 000 402 0041 Removable hinged 10 pan cover 000 402 0045 Removable hinged 12 pan cover XMK00001 19 Door Assembly XMK00003 27 Door Assembly XMK00108 Evaporator Coil assy W Solenoid XMK00109 Evaporator Coil Assembly XMK00120 Complete Louver Assembly 3526731 Condensing Unit 3526752 Compressor 3977984 Wire shelf 19 3978014 Wire Shelf 27 F18DC99 SMK00776 Center divider bar 000 402 0045 Removable hinged 12 pan cover XMK00003 27 Door Assembly XMK00108 Evaporator Coil assy W Solenoid XMK00109 Evaporator Coil Assembly XMK00120 Complete Louver Assembly 3526731 Condensing Unit 3526752 Compressor 3978014 Wire Shelf 27 F18DR SERIES STANDARD PARTS 1701000 Cutting board pin 2190154 Rocker switch 2194201 Rail Thermostat 3234282 Left end pan cover hinge 3234266 Right end pan cover hinge 3234392 Double center hinge pan cover 3234290 Plastic support shelf 3234645 Leg 3516101 Filter dryer 3516102 Solenoid valve 3516135 Thermometer 3516225 Expansion valve rail 9321041 Acorn Nut for Salad pan Cover pin 9321132 Long dog point stud 9321136 Cutting board pin 9321374 Salad pan cover pin hinge ADDITIONAL PARTS F18DR44 000 402 0041 Removable hinged 12 pan cover XMKO00001 19 Door Assembly XMK00009 Evaporator Coil Assembly 3977984 19 Wire Shelf F18DR52 000 402 0045 Removable hinged 12 pan cover XMKO00001 19 Door Assembly XMK00003 27 Door
11. Year Protection Plan or applicable Delfield Service Labor Contract the Original Purchaser agrees and acknowledges that no other warranties are offered or provided in connection with or for the unit or any other part thereof In no event will Delfield be liable for special incidental or con sequential damages or for damages in the nature of penalties 9 Delfield F18 Series Service and Installation Manual Additional Four Year Protection Plan for Motor Compressor only Installation Delfield Model Serial Date In addition to the Standard Year Warranty on the Motor Compressor contained in the above listed Delfield product the Unit The Delfield Company Delfield also agrees to repair or exchange with similar or interchangeable parts in design and capacity at Delfield s option the defective Motor Compressor contained in the Unit the Motor Compressor or any part thereof for the Original Purchaser only at any time during the four 4 years following the initial one 1 year period commencing on the date of installation for the Original Purchaser Failure of the Original Purchaser to register the registration card containing the Original Purchasers name address date of installation model number and serial number of the Unit containing the Motor Compres sor within 30 days from the date of installation shall void this warranty This additional warranty is only available if the M
12. cover XMK00005 19 Lo Profile Door Assembly XMK00007 27 Lo profile door assembly F18SC60D SERIES 000 402 003T Removable 6 pan hinged cover XMK00005 19 Lo Profile Door Assembly XMK00007 27 Lo profile door assembly F18SR SERIES STANDARD PARTS XMK00109 Coil assembly solenoid 1701000 Cutting board pin 2183348 Cord plug assembly 2190154 On Off Switch 2193927 Pressure control 3234266 Right pan cover end hinge 3234282 Left end pan cover hinge 3234392 Double Center pan cover hinge 3234645 Leg 3516135 Hanging 4 thermometer 3516225 Expansion valve 9321041 Chrome plated acorn nut 9321136 Holding for cutting board pin 9321374 Salad pan cover pin hinge ADDITIONAL PARTS F18SR31A amp F18SR44A SERIES 000 402 003T Removable 6 pan hinged cover XMK00005 19 Lo Profile Door Assembly F18SR44B SERIES 000 402 003X Removable 8 pan hinged cover XMK00005 19 Lo Profile Door Assembly F18SR44C SERIES 000 402 0041 Removable 10 pan hinged cover XMK00005 19 Lo Profile Door Assembly F18SR52A SERIES 000 402 003T Removable 6 pan hinged cover XMK00005 19 Lo Profile Door Assembly XMK00007 27 Lo Profile Door Assembly F18SR52B SERIES 000 402 003X Removable 8 pan hinged cover XMK00005 19 Lo Profile Door Assembly XMK00007 27 Lo Profile Door Assembly F18SR52C SERIES 000 402 0041 Removable 10 pan hinged cover XMK00005 19 Lo Profile Door Assembly XMK00007 27 Lo Profile Door Assembly F18SR52D SERIES 000
13. cutting board pin 9321374 Salad pan cover pin hinge ADDITIONAL PARTS F18RC52 000 402 0045 Hinged Removable Cover XMK00001 19 Door Assembly XMK00109 Evaporator Coil Assembly XMK00118 Louver Assembly 2183348 Cord plug assembly 3526745 Cond Unit 3526768 Compressor 3977984 Wire shelf 19 F18RC60 000 402 003X 8 pan hinged removable cover 000 402 003T 6 pan hinged removable cover SMK00776 Center divider bar XMK00001 19 Door Assembly XMK00003 27 Door Assembly XMKO00109 Evaporator Assembly XMK00118 Louver Assembly 2183348 Cord plug assembly 3526746 Condensing Unit 3526750 Compressor 3977984 19 Wire Shelf 3978014 27 Wire Shelf For customer service call 800 733 8829 800 773 8821 Fax 989 773 3210 www delfield com 1 7 F18 Series Service and Installation Manual F18RC68 000 402 003X 8 pan hinged removable cover 000 402 003T 6 pan hinged removable cover SMK00776 Center divider bar XMK00003 27 Door Assembly XMK00109 Evaporator Assembly XMK00118 Louver Assembly 2183348 Cord plug assembly 3526746 Cond Unit 3526750 Compressor 3978014 27 Wire Shelf F18RC72 000 402 0041 10 pan hinged removable cover 000 402 003X 8 pan hinged removable cover XMK00003 27 Door Assembly XMK00109 Evaporator Assembly XMK00120 Louver Assembly 2183347 Cord Plug Assembly 3526731 Condensing Unit 3526752 Compressor 3978014 27 Wire Shelf F18RC82 000 402 0041 10 pan hinged removable cover XMK00004 32
14. door assy 3978014 27 Wire Shelf F18SC SERIES STANDARD PARTS XMK00109 Coil assembly solenoid XMK00118 Louver Assembly 1701000 Cutting board pin 2190154 on off switch 2194201 Rail Thermostat 2194536 Thermostat 3234266 Right pan cover end hinge 3234282 Left end pan cover hinge 3234392 Double Center pan hinge 3234645 Leg 3516135 Hanging 4 thermometer 3516225 Expansion valve 9321041 Chrome plated acorn nut 9321136 Holding for cutting board pin 9321374 Salad pan cover pin hinge ADDITIONAL PARTS F18SC39A SERIES 000 402 003T Removable 6 pan hinged cover XMK00005 19 Lo Profile Door Assembly F18SC39B F18SC52B 000 402 003X Removable 8 pan cover XMK00005 19 Lo Profile Door Assembly F18SC52A SERIES 000 402 003T Removable 6 pan hinged cover XMK00005 19 Lo Profile Door Assembly F18SC52C SERIES 000 402 0041 Removable 10 pan hinged cover XMK00005 19 Lo Profile Door Assembly F18SC52D SERIES 000 402 0045 Removable 12 pan hinged cover XMK00005 19 Lo Profile Door Assembly F18SC60A SERIES 000 402 003T Removable 6 pan hinged cover XMK00005 19 Lo Profile Door Assembly XMK00007 27 Lo Profile Door assembly 1 8 For customer service call 800 733 8829 800 773 8821 Fax 989 773 3210 www delfield com F18SC60B SERIES 000 402 003T Removable 6 pan hinged cover XMK00005 19 Lo Profile door assembly XMK00007 27 Lo profile door assembly F18SC60C SERIES 000 402 003T Removable 6 pan hinged
15. 16135 Thermometer 3516101 Filter dryer 3516225 Expansion valve Rail 9321041 Acorn Nut for pan cover hinge 9321132 Dog point stud 9321136 Cutting Board Pin 9321374 Salad pan cover pin hinge ADDITIONAL PARTS F18DC52 000 402 0045 Removable hinged 12 pan cover XMK00001 19 Door Assembly XMK00109 Evaporator Coil Assembly XMK00118 Complete Louver Assembly 3526745 Condensing Unit 3526768 Compressor 3977984 Wire shelf F18DC60 000 402 003T Removable hinged 6 pan cover 000 402 003X Removable hinged 8 pan cover SMK00776 Center divider bar XMK00001 19 Door Assembly XMK00003 27 Door Assembly XMK00109 Evaporator Coil Assembly XMK00118 Complete Louver Assembly 3526746 Condensing Unit 3526750 Compressor 3977984 Wire shelf 19 3978014 Wire shelf 27 F18DC68 000 402 003X Removable hinged 8 pan cover XMK00003 27 Door Assembly XMK00109 Evaporator Coil Assembly XMK00118 Complete Louver Assembly 3234392 Double hinge pan cover 3526746 Cond Unit 3526750 Compressor 3978014 Wire shelf 27 F18DC72 000 402 003X Removable hinged 8 pan cover 000 402 0041 Removable hinged 10 pan cover XMK00003 27 Door Assembly XMK00109 Evaporator Coil Assembly XMK00120 Complete Louver Assembly 3526731 Condensing Unit F18DC82 SMK00776 Center divider bar 000 402 0041 Removable hinged 10 pan cover XMK00004 32 Door Assembly XMK00109 Evaporator Coil Assembly XMK00120 Complete Louver Assembly 3526731 Condensing Unit 3526752
16. 27 F18WR87 SERIES XMK00003 Door assembly 27 3978014 Wire Shelf 27 F18 Series Service and Installation Manual For customer service call 800 733 8829 800 773 8821 Fax 989 773 3210 www delfield com 1 9 F18 Series Service and Installation Manual Wiring Diagram Refrigerated Base Work Tables F18WC L1 3 ONDE SWITCH ON 115 VOLT MODELS ONLY 12 L2 IS THE NEUTRAL PRESSURE CONTROL EVAPORATOR FAN S POWER CORD PROVIDED ON SELF CONTAINED MODELS Wiring Diagram netrigerated Base amp Reduced Rail Tables F18MC F18SC F18BC amp F18RC L1 BASE ON 115 VOLT MODELS ONLY L2 IS THE NEUTRAL O SWITCH L2 CONDENSING UNIT POWER CORD PROVIDED ON SELF CONTAINED MODELS NOTE with LiquiTec same drawing but remove receptacle for optional fan package Only on LiquiTec o d SOLENOID VALVE 20 SWITCH E T STAT Not on LiquiTec SC RECEPTACLE FOR OPTIONAL FAN PACKAGE For customer service call 800 733 8829 800 773 8821 Fax 989 773 3210 www delfield com Delfield F18 Series Service and Installation Manual Wiring Diagram Freezer Base Work Tables F18FC ON OFF SWITCH CONDENSING UNIT BLACK ____ Mi PRESS T SC SWITCH PURPLE ORANGE DEFROST HEATER DOOR FRAME HEATER MULLION HEATER C Delfield For customer service call 800 733 8
17. 402 0045 Removable 12 pan hinged cover XMK00005 19 Lo Profile Door Assembly XMK00007 27 Lo Profile Door Assembly 9 Delfield F18WC SERIES STANDARD PARTS SMK00039 Louver XMK00107 Evaporator Coil Assembly 1701000 Cutting board pin 2183348 Cord plug assembly 2193927 Pressure control 3234290 Plastic plug shelf support 3234645 Leg 3516135 Hanging 4 thermometer 9321041 Chrome plated acorn nut 9321132 Long stud dog point 9321136 Holding for cutting board pin 9321374 Salad pan cover pin hinge ADDITIONAL PARTS F18WC39 SERIES SMK00039 Louver Assembly XMK00001 Door assembly 19 3526747 Condensing Unit 3526762 Compressor 3977984 19 Wire Shelf F18WC47 SERIES SMK00039 Louver Assembly XMK00003 Door assembly 27 3526747 Condensing Unit 3526762 Compressor 3978014 27 Wire Shelf F18WC52 SERIES SMK00039 Louver Assembly XMK00001 Door assembly 19 3526747 Condensing Unit 3526762 Compressor 3977984 19 Wire Shelf F18WC60 SERIES SMK00039 Louver Assembly XMK00001 Door assembly 19 XMK00003 Door assembly 27 3526747 Condensing Unit 3526762 Compressor 3977984 19 Wire Shelf 3978014 27 Wore Shelf F18WC68 SERIES SMK00039 Louver Assembly XMK00003 Door assembly 27 3526745 Condensing Unit 3526768 Compressor 3978014 Wire Shelf 27 F18WC78 SERIES SMK00039 Louver Assembly XMK00004 Door assembly 32 3526745 Condensing Unit 3526768 Compressor 3977983 32 Wire Shelf F18WC87 SERIES SMK00039 Louver Asse
18. 6 0304 00 coil condenser 085 7031 01 control high pressure 083 0102 00 blade fan 571 0431 00 receiver tank Refrigerant charges gas refrigerant 404A 4807 Delfield Refrigerant charges gas refrigerant 404A 56 oz For customer service call 800 733 8829 800 773 8821 Fax 989 773 3210 www delfield com 9 F18 Series Service and Installation Manual Coil Assembly refrigerators DELFIELD PART K00036 DESCRIPTION pan drip evap coil refg K00011 coil back coil side AMK00012 5 K00285 3516173 bracket mounting fan evap coil guard fan 6 38 dia lexan 3516095 AMK00013 coil evap coil front 3516172 2162691 o co ola ajo blade fan 5 56 CCW lexan clear motor fan 115V 3516273 3516103 valve expansion 1 4 hi R 404A solenoid coil 3516102 2194536 1 0 For customer service call 800 733 8829 800 773 8821 Fax 989 773 3210 www delfield com solenoid valve thermostat XMK00107 EVAPORATOR COIL ASSEMBLY Coil assembly is standard with above parts less solenoid coil solenoid valve and thermostat Unit F18WC XMK00108 EVAPORATOR COIL ASSEMBLY Coil assembly is standard with above parts less the thermostat Unit F18DC91 amp 99 Fi8DR79 amp 97 F18RC91 amp 99 F18WR79 amp 87 XMK00109 EVAPORATOR COIL ASSEMBLY Coil assembly is standard with above parts less the
19. 829 800 773 8821 Fax 989 773 3210 www delfield com 2 1 F18 Series Service and Installation Manual Standard One Year Warranty one year parts 90 days labor The Delfield Company Delfield warrants to the Original Purchaser of the Delfield product herein called the Unit that such Unit and all parts thereof will be free from defects in material and workmanship under normal use and service for a period of one 1 year from the date of shipment of the Unit to the Original Purchaser or if the Original Purchaser returns the warranty card completely filled out including the date of installation within thirty 30 days of receipt of the Unit one 1 year from the date of installation During this one year warranty period Delfield will repair or replace any defec tive part or portion there of returned to Delfield by the Original Purchaser which Delfield determines was defective due to faulty material or workmanship The Original purchaser will pay all labor crating freight and related costs incurred in the removal of the Unit of defective component and shipment to Delfield except that during a period of either ninety 90 days from the date of shipment of the Unit to the Original Purchaser or if the Original Purchaser returns the warranty card com pletely filled out including the date of installation within thirty 30 days of receipt of the Unit ninety 90 days from the date of installation Delfield will pay all re
20. AA 201 DESCRIPTION 1 2 H P low condensing unit 3526752 JS35C1E CAA 959 welded compressor 040 0001 54 relay quick connect 3526760 RS43C1E IAA 958 compressor 040 0102 00 relay current 014 0008 64 capacitor starting 071 7004 01 overload protector 050 0276 00 motor fan 066 0273 00 coil condenser 014 0008 57 capacitor starting 071 0329 15 overload protector 050 0259 10 motor fan 066 0303 00 coil condenser 083 0133 00 blade fan 577 0346 01 receiver tank 085 7031 01 control high pressure 083 0130 00 blade fan 577 0346 02 receiver tank Refrigerant charges gas refrigerant 404A 3207 Used On F18DC99 and F18RC99 3 4 HORSE POWER MEDIUM DELFIELD COPELAND KEY PART PART 3526732 FJEM A075 CAA 244 DESCRIPTION 3 4 H P med condensing unit 3526753 JS55C1E CAA 959 welded compressor 040 0001 60 relay Refrigerant charges gas refrigerant 404A 4007 Used On F18FC70 78 amp 88 3 4 HORSE POWER LOW DELFIELD COPELAND KEY PART PART 3526712 FJAF A075 CAA 201 DESCRIPTION 3 4 H P low condensing unit 014 0008 61 capacitor starting 071 7004 00 overload protector 3526761 RS64C1E CAA 959 welded compressor 040 0001 60 relay 050 0244 01 motor fan 066 0304 00 coil condenser 014 008 74 capacitor starting 071 0127 43 overload protector 083 0102 00 blade fan 571 0431 01 receiver tank 050 0244 01 motor fan 06
21. Assembly XMK00109 Evaporator Coil Assembly 3526752 Compressor 3977984 19 Wire shelf 3978014 Wire shelf 27 3978014 27 Wire Shelf 1 6 For customer service call 800 733 8829 800 773 8821 Fax 989 773 3210 www delfield com F18DR60 SMK000776 Center divider bar 000 402 003T Removable hinged 6 pan cover 000 402 003X Removable hinged 8 pan cover XMK00003 27 Door Assembly XMK00109 Evaporator Coil Assembly 3978014 Wire shelf 27 F18DR70 000 402 003X Removable hinged 8 pan cover XMK00004 32 Door Assembly XMKO00109 Evaporator Coil Assembly 3977983 Wire shelf 32 F18DR79 SMK00776 Center divider bar 000 402 0041 Removable hinged 10 pan cover XMK00001 19 Door Assembly XMK00003 27 Door Assembly XMK001028 Evaporator Coil Assembly w solenoid XMK00109 Evaporator Coil Assembly 3977984 19 wire shelf 3978014 27 wire shelf F18DR87 SMK00776 Center divider bar 000 402 0041 Removable hinged 10 pan cover 000 402 0045 Removable hinged 12 pan cover XMK00003 27 Door Assembly XMK001028 Evaporator Coil Assembly w solenoid XMKO00109 Evaporator Coil Assembly 3977984 Wire shelf 19 3978014 Wire Shelf 27 F18FC SERIES STANDARD PARTS XMK00061 Coil assembly freezer XMK00065 Evap condensate pan and heater 2193927 Low pressure control 2194046 Fan delay defrost control limit 2194199 Heating cond evap element 2194151 Defrost timer 2194235 Heater safety switch 3234290 Plastic support shelf 3234645 Leg 3516101 Fi
22. Assembly XMK00007 D 32 Lo Profile Door Assembly F18MR SERIES STANDARD PARTS XMK00109 Evaporator Coil Assembly 1701000 Cutting board pin cap 2190154 On Off switch 2194201 Thermostat rail 3234266 Right end pan cover hinge 3234282 Left end pan cover hinge 3234392 Double Center cover hinge 3234645 Leg 3516135 Thermometer 3516225 Expansion valve 9321136 Holding for cutting board pin 9321374 Salad pan cover pin hinge 9321041 Chrome plated acorn nut ADDITIONAL PARTS F18 Series Service and Installation Manual F18MR31A amp F18MR44A 000 402 003G 6 Pan Cover XMK00005 19 Lo Prof F18MR44D 000 402 003 12 pan h XMK00005 19 Lo Prof F18MR52A amp F18MR52D ile Door Assembly inged removable cover ile Door Assembly 000 402 003G Hinged Removable 6 pan Cover XMK00005 19 Lo Prof XMK00007 27 Lo Prof F18MR52E 000 402 003K 18 pan XMK00005 19 Lo Prof XMK00007 27 Lo Prof ile Door Assembly ile Door Assembly hinged removable cover ile Door Assembly ile Door Assembly F18RC SERIES STANDARD PARTS 1701000 Cutting board pin 2190154 On Off switch 2193927 Pressure control 3234266 Right pan cover end hinge 3234282 Left pan cover end hinge 3234290 Plastic plug shelf support 3234392 Double Center cover hinge 3234645 Leg 3516101 Filter dryer 3516135 Hanging 4 thermometer 3516225 Expansion valve 9321040 Stud spot 9321041 Chrome plated acorn nut 9321132 Long stud dog point 9321136 Holding for
23. Delfield s MARK modular equipment F18 SERIES Service and Installation Manual Please read this manual completely before attempting to install or operate this equipment Notify carrier of damage Inspect all components immediately See page 2 Refrigerated Work Tables Salad Tables amp Freezer Bases Effective Date October 2002 F18 Series Service and Installation Manual Contents JH SEerial Number Location SERIAL NUMBER 2 RECEIVING amp INSPEGTING_ u ua 2 SPECIFICATIONS at s a anna anam sasaqa asss 3 5 INSTALLATION 6 OPERATION tt tee fco eee tread cic 6 GARE AND CLEANING ctor retenti 7 PRESSURE CONTROL SETTINGS 7 CONDENSING UNIT ASSEMBLY 8 9 MULLION COIL ASSEMBLY REFRIGERATED 10 MULLION COIL ASSEMBLY FREEZER 11 DRAWER ASSEMBLY LOW PROFILE REFR 2 amp 3 HIGH 12 CARTRIDGE STYLE DRAWER SYSTEMS 13 DOOR ASSEMBLY LOW PROFILE ees 14 DOOR ASSEMBLY MARK 7 15 LOUVERED DOOR ASSEMBLY 15 REPLACEMENT PARTS LISTS 16 19 WIRING DIAGRAMS seen 20 TROUBLESHOOTING REFERENCE 21 WA
24. Manual Specifications MODEL OF STORAGE SHELF AREA OF RECOMMENDED VOLTS HERTZ BTU DESIGN LOAD EVAP CAP NUMBER DOORS CU FT SQ FT PANS HORSE POWER PHASE AMPS BASE RAIL BTU TD Remote Refrigerated Reduced Height Rail F18RR44 2 19 9 49 5 12 10 1 4 115 60 1 3 0 547 441 120 19 F18RR52 1 19 amp 1 27 11 81 6 51 12 1 3 115 60 1 3 0 625 529 120 23 F18RR60 2 27 14 14 7 9 16 1 3 115 60 1 5 0 703 617 120 26 F18RR70 2 32 17 05 9 64 18 1 2 115 60 1 5 0 800 794 120 32 F18RR79 1 19 amp 2 27 18 68 10 29 18 1 2 115 60 1 5 0 962 882 240 36 F18RR87 3 27 21 30 11 85 22 3 4 115 60 1 5 0 1032 970 240 39 MODEL OF STORAGE SHELF AREA OF VOLTS HERTZ BTU LOAD BTU SYSTEM CAP NUMBER DOORS CU FT SQ FT PANS HORSE POWER PHASE AMPS BASE RAIL BASE RAIL Self Contained Refrigerated Reduced Height Rail F18RC52 2 19 9 49 5 12 12 1 4 115 60 1 10 0 547 529 1903 1061 F18RC60 1 19 amp 1 27 11 81 6 51 14 1 3 115 60 1 12 0 625 617 2314 1121 F18RC68 2 27 14 14 7 9 18 1 3 115 60 1 12 0 703 794 2314 1544 F18RC82 2 32 17 05 9 64 20 1 2 115 60 1 14 0 800 882 3097 1648 F18RC91 1 19 amp 2 27 18 68 10 29 22 1 2 115 60 1 14 0 962 1058 3807 1839 F18RC99 3 27 21 30 11 85 24 3 4 115 60 1 16 0 1032 1147 5286 2191 A 5 15P NEMA plug is used on F18RC52 F18RC60 amp F18RC68 5 20P NEMA plug is used on F18RC82 F18RC91 amp F18RC99 MODEL OF STORAGE SHELF AREA RECOMMENDED VOLTS HERTZ BTU EVAP CAP
25. R52A 1 19 amp 1 27 6 51 6 1 4 115 60 1 3 0 532 529 120 F18SR52B 1 19 amp 1 27 6 51 8 1 4 115 60 1 3 0 532 529 120 F18SR52C 1 19 amp 1 27 6 51 10 1 4 115 60 1 3 0 532 529 120 F18SR52D 1 19 amp 1 27 6 51 12 1 4 115 60 1 3 0 532 529 120 MODEL OF SHELFAREA 0 VOLTS HERTZ BTU DESIGN BTU SYSTEM CAP NUMBER DOORS SQ FT PANS HORSE POWER PHASE AMPS BASE RAIL BASE RAIL Self Contained Refrigerated Salad Top Tables F18SC39A 1 19 2 56 6 1 4 115 60 1 10 0 280 265 1903 745 F18SC39B 1 19 2 56 8 1 4 115 60 1 10 0 280 353 1903 867 F18SC52A 2 19 5 12 6 1 4 115 60 1 10 0 444 265 1903 745 F18SC52B 2 19 5 12 8 1 4 115 60 1 10 0 444 353 1903 867 F18SC52C 2 19 5 12 10 1 4 115 60 1 10 0 444 441 1903 971 F18SC52D 2 19 5 12 12 1 4 115 60 1 10 0 444 529 1903 1061 F18SC60A 2 19 amp 1 27 6 51 6 1 4 115 60 1 10 0 515 265 2314 667 F18SC60B 2 19 amp 1 27 6 51 8 1 4 115 60 1 10 0 515 353 2314 798 F18SC60C 2 19 amp 1 27 6 51 10 1 4 115 60 1 10 0 515 441 2314 916 F18SC60D 2 19 amp 1 27 6 51 12 1 4 115 60 1 10 0 515 529 2314 1023 A 5 15 NEMA plug is used on self contained units MODEL NUMBER Remote Refrigerated Reduced Height Rail F18DR44 F18DR52 F18DR60 F18DR70 F18DR79 F18DR87 MODEL NUMBER OF DOORS 2 19 1 19 amp 1 27 2 27 2 32 1 19 amp 2 27 3 27 OF DOORS STORAGE CU FT 9 49 11 81
26. R60 2 27 18 85 7 90 1 4 115 60 1 3 0 768 120 F18WR70 2 32 20 59 9 64 1 4 115 60 1 3 0 869 120 F18WR79 2 27 amp 1 19 23 05 10 29 1 4 115 60 1 6 0 1050 240 F18WR87 3 27 25 83 11 85 1 4 115 60 1 6 0 1131 240 MODEL OF STORAGE SHELF AREA VOLTS HERTZ BTU BTU NUMBER DOORS CU FT SQ FT HORSE POWER PHASE AMPS LOAD SYSTEM Self Contained Refrigerated Work Tables F18WC39 1 19 6 99 2 56 1 5 115 60 1 8 0 383 1462 F18WC47 1 27 9 77 3 95 1 5 115 60 1 8 0 465 1462 F18WC52 2 19 11 52 5 12 1 5 115 60 1 8 0 605 1462 F18WC60 1 19 amp 1 27 14 31 6 51 1 5 115 60 1 8 0 686 1462 F18WC68 2 27 18 85 7 90 1 4 115 60 1 10 0 768 1462 F18WC78 2 32 20 59 9 64 1 4 115 60 1 10 0 869 1994 F18WC87 2 27 amp 1 19 23 05 10 29 1 4 115 60 1 10 0 1050 2261 F18WC95 3 27 25 83 11 85 1 4 115 60 1 10 0 1131 2261 5 15P NEMA plug is used on self contained units MODEL OF STORAGE X OF RECOMMENDED VOLTS HERTZ BTU DESIGN EVAP CAP BTU TD NUMBER DOORS CU FT PANS HORSE POWER PHASE AMPS BASE RAIL BASE RAIL Remote Refrigerated Mega Top Salad Tables F18MR31A 1 19 441 6 1 4 115 601 30 280 265 120 12 F18MRA4A 2 19 6 94 6 1 4 115 60 1 30 444 265 120 12 F18MR44D 2 19 6 94 12 1 4 115 601 3 0 444 529 120 22 F18MR52A 1 19 amp 1 27 8 69 6 13 11560130 515 265 120 12 FI8MR52D 1 19 amp 1 27 8 69 12 1 3 115 601 30 515 529 120 22 F18MR52E 1 19 amp 1 27 8 69 18 1 3 115 601 30
27. RRANTIES i eret thia oett tts 22 23 AUTHORIZED PARTS back cover The serial number on all self contained F18 Series refriger ated work tables and freezer bases is located on the electri cal specifications tag affixed inside the compressor section next to the pressure control On remote refrigerated bases with doors the tag is inside the unit on the coil side On remote refrigerated bases with draw ers the tag is affixed to the drawer divider On remote freezer bases the tag is located on the inside back of the unit Always have the serial number of your unit available when calling for parts or service A complete list of authorized Delfield parts depots is shown on the back cover of this manual 2002 The Delfield Company All rights reserved Reproduction without written permission is prohibited Delfield is a registered trademark of The Delfield Company Receiving and Inspecting the Equipment Even though most equipment is shipped crated care should be taken during unloading so the equipment is not damaged while being moved into the building 1 Visually inspect the exterior of the package an skid or container Any damage should be noted and reported to the delivering carrier immediately 2 f damaged open and inspect the contents with the carrier 3 In the event that the exterior is not damaged yet upon opening there is concealed damage to the equipment notify the c
28. arrier Notification should be made verbally as well as in written form 4 Requestan inspection of the concealed equipment This should be done within 10 days from receipt of the equipment 5 Check the lower portion of the unit to be sure legs or casters are not bent 2 For customer service call 800 733 8829 800 773 8821 Fax 989 773 3210 www delfield com 6 Also open the compressor compartment housing and visually inspect the refrigeration package Be sure lines are secure and base is still intact 7 Freight carriers can supply the necessary forms upon request 8 Retain all crating material until an inspection has been made or waived Uncrating the Equipment First cut and remove the banding from around the crate Remove the front of the crate material use of some tools will be required If the unit is on legs remove the top of the crate as well and lift the unit off the skid If the unit is on casters it can be rolled off the skid 9 Delfield F18 Series Service and Installation Manual Specifications MODEL OF STORAGE SHELF AREA RECOMMENDED VOLTS HERTZ BTU EVAP CAP NUMBER DOORS CU FT SQ FT HORSE POWER PHASE AMPS LOAD BTU TD Remote Refrigerated Work Tables F18WR31 1 19 6 99 2 56 1 5 115 60 1 3 0 383 120 F18WR39 1 27 9 77 3 95 1 5 115 60 1 3 0 465 120 F18WR44 2 19 11 52 5 12 1 5 115 60 1 3 0 605 120 F18WR52 1 19 amp 1 27 14 31 6 51 1 5 115 60 1 3 0 686 120 F18W
29. ce to allow any hood s vent s or Unit s if necessary to be brought into the building Delfield will not be responsible for structural changes or damages incurred during installation of the Unit or any exhaust system Delfield shall not be liable in any manner for any default or delay in performance hereunder caused by or resulting from any contingency beyond Delfield s control including but not limited to war governmental restrictions or restraints strike lockouts injunctions fire flood acts of nature short or reduced supply of raw materials or discontinuance of the parts by the original part manufacturer Except as provided in any Additional Four Year Protec tion Plan if applicable and the Service Labor Contract if applicable the foregoing is exclusive and in lieu of all other warranties whether written or oral express or implied This warranty supersedes and excludes any prior oral or written representations or warranties Delfield expressly disclaims any implied warranties of merchant ability fitness for a particular purpose of compliance with any law treaty rule or regulation relating to the discharge of substances into the environment The sole and exclu sive remedies of any person relating to the Unit and the full liability of Delfield for any breach of this warranty will be as provided in this warranty Other than this Delfield Standard One Year Limited Warranty any applicable Delfield Additional Four
30. denser cleaner may be required Cleaning door gaskets Door gaskets should be cleaned as required to maintain their ability to seal properly Do not use sharp tools or knives to scrape the bellows as this may tear the gasket and eliminate its ability to seal A soft bristle brush and solution of soap and water should be all that is required to keep the gaskets clean Do not use full strength degreasing agents on the gasket because they could cause the gasket to become brittle and crack Consistent cleaning of the coil will enhance the A Operation of the unit by reducing energy consump tion as well as extend the life of the compressor NOTE Preventing blower coil corrosion To help prevent corrosion of the blower coil store all acidic items such as pickles and tomatoes in sealable containers Immediately wipe up all spills of items Pressure Control Settings Factory recommended low pressure control settings are HFC 404A refrigerators 85 cut in and 65 cut out to maintain approximate interior temperature of 38 F Differential setting of 20 HFC 404A freezers 32 cut in and 8 cut out to maintain approximate interior temperature of 0 F to 5 F Differential setting of 247 HFC 404A refrigerators with LiquiTec Rail 207 cut in and 107 cut out to Differential setting of 107 Temperature control for LiquiTec Rail 25 F cut in and 18 F cut out Pressure control settings are measured in pounds not fahrenheit NOTE
31. e shelf 3978014 27 Wire shelf F18FR66 SERIES XMK00004 32 Door Assembly 3977983 32 Wire shelf F18FR76 SERIES XMK00004 32 Door Assembly 3977983 32 Wire Shelf 9 Delfield F18MC SERIES STANDARD PARTS XMK00005 19 Lo Profile Door Assembly XMK00109 Evaporator Coil Assembly XMK00118 Louver Assembly 2183348 Cord plug assy 2190154 On Off Switch 2193927 Low pressure control 3234266 Right end pan cover hinge 3234282 Left end pan cover hinge 3234392 Double center hinge pan cover 3234645 Leg 3516101 Filter dryer 3516135 Thermometer 3526745 Cond Unit 3526768 Compressor 9321041 Chrome plated acorn nut 9321136 Holding for cutting board pin 9321374 Salad pan cover pin hinge ADDITIONAL PARTS F18MC394A Series 000 402 003G 6 Pan Cover XMK00005 19 Lo Profile Door Assembly F18MC39D Series 000 402 0031 12 Pan Cover XMKO00005 19 Lo Profile Door Assembly F18MC524A Series 000 402 003G 6 Pan Cover XMK00005 19 Lo Profile Door Assembly F18MC52D Series 000 402 0031 12 Pan Cover XMK00005 19 Lo Profile Door Assembly F18MC52E Series 00 402 003K 18 Pan Cover XMK00005 19 Lo Profile Door Assembly F18MC60A Series 000 402 003G 6 Pan Cover XMKO00005 19 Lo Profile Door Assembly XMK00007 B 32 Door Assembly F18MC60D Series XMK00005 19 Lo Profile Door Assembly XMK00007 D 32 Door Assembly 000 402 0031 12 Pan Cover F18MC60E Series 000 402 003K 18 Pan Cover XMK00005 19 Lo Profile Door
32. lated labor costs Delfield will pay the return costs if the Unit or part thereof was defec tive The term Original Purchaser as used herein means that person firm association or corporation for whom the Unit was originally installed This warranty does not apply to any Unit or part thereof that has been subjected to misuse neglect alteration or accident such as accidental damage to the exterior finish operated contrary to the recommendations specified by Delfield or repaired or altered by anyone other than Delfield in any way so as to in Delfield s sole judgement affect its quality or effi ciency This warranty does not apply to any Unit that has been moved from the location where it was originally installed This warranty also does not cover the refrigerator drier or the light bulbs used in the Unit The warranty is subject to the user s normal maintenance and care responsibility as set forth in the Service and Installation Manual such as cleaning the condenser coil and is in lieu of all other obligations of Delfield Delfield neither assumes nor authorizes any other person to assume for Delfield any other liability in connection with Delfield s products Removal or defacement of the original Serial Number or Model Number from any Unit shall be deemed to release Delfield from all obligations hereunder or any other obligations express or implied Parts furnished by suppliers to Delfield are guaranteed by Delfie
33. ld only to the extent of the original manufacturer s express warranty to Delfield Failure of the Original Purchaser to receive such manufacturer s express warranty to Delfield Failure of the Original Purchaser to receive such manufactur ers warranty shall in no way create any warranty expressed or implied or any other obligation or liability on Delfield s part in respect thereof 22 For customer service call 800 733 8829 800 773 8821 Fax 989 773 3210 www delfield com If shipment of a replacement part is requested prior to the arrival in the Delfield factory of the part claimed to be defec tive the Original Purchaser must accept delivery of the replacement part of a C O D basis with credit being issued after the part has been received and inspected at Delfield s plant and determined by Delfield to be within this warranty Under no condition does this warranty give the Original Pur chaser the right to replace the defective Unit with a complete Unit of the same manufacturer or of another make Unless authorized by Delfield in writing this warranty does not permit the replacement of any part including the motor compressor to be made with the part of another make or manufacturer No claims can be made under this warranty for spoilage of any products for any reason including system failure The installation contractor shall be responsible for building access entrance and field conditions to insure sufficient clear an
34. lter dryer 3516135 Thermometer 9321040 Spot stud 9321132 Long dog point stud ADDITIONAL PARTS F18FC43 SERIES SMK00039 Clip on Louver XMK00001 19 Door Assembly 2183348 Cord plug assy 3526710 Condensing Unit 3526749 Compressor 3977984 Shelf 19 F18FC62 SERIES SMK00039 Louver Assembly XMK00001 19 Door Assembly 2183348 Cord plug assy 3526711 Condensing Unit 3526749 Compressor 3977984 19 Wire shelf 9 Delfield F18FC70 SERIES SMK00041 Louver Door Assembly XMK00001 19 Door Assembly XMK00003 27 Door Assembly 2183347 Cord Plug Assembly 3526712 Condensing unit 3526761 Compressor 3977984 19 Wire shelf 3978014 27 Wire shelf F18FC78 SERIES SMK00041 Louver Assembly XMK00003 27 Door Assembly 2183347 Cord Plug Assembly 3526712 Condensing unit 3526761 Compressor 3978014 Wire shelf F18FC88 SERIES SMK00041 Louver Assembly XMK00004 32 Door Assembly 2183347 Cord Plug Assembly 3526712 Condensing unit 3526761 Compressor 3977983 Wire shelf F18FR SERIES STANDARD PARTS XMK00061 Coil assembly freezer 2194046 Fan delay defrost control limit 2194151 Defrost timer 2194235 Heater safety switch 3234290 Plastic support shelf 3234645 Leg 3516135 Thermometer 9321040 Spot stud 9321132 Long dog point stud ADDITIONAL PARTS F18FR35 and F18FR50 SERIES XMK00001 Door Assembly 3977984 19 Wire shelf F18FR58 Series XMK00001 19 Door Assembly XMK00003 27 Door Assembly 3977984 19 Wir
35. mbly XMK00001 Door assembly 19 XMK00003 Door assembly 27 3526745 Condensing Unit 3526768 Compressor 3977984 19 Wire Shelf 3978014 27 Wire Shelf Delfield F18WC95 SERIES SMK00039 Louver Assembly XMK00003 Door assembly 27 3526745 Condensing Unit 3526768 Compressor 3978014 27 Wire Shelf F18WR SERIES STANDARD PARTS 1701000 Cutting board pin 3234290 Plastic plug shelf support 3234645 Leg 3516135 Hanging 4 thermometer 9321040 Stud spot 9321041 Chrome plated acorn nut 9321132 Long stud dog point 9321136 Holding for cutting board pin 9321374 Salad pan cover pin hinge ADDITIONAL PARTS F18WR31 SERIES XMK00001 Door assembly 19 XMK00109 Evaporator Coil Assembly 3977984 Wire shelf 19 F18WR39 SERIES XMK00003 Door assembly 27 XMK00109 Evaporator Coil Assembly 3978014 Wire shelf 27 F18WR44 SERIES XMK00001 Door assembly 19 XMK00109 Evaporator Coil Assembly 3977984 Wire shelf 19 F18WR52 SERIES XMK00001 Door assembly 19 XMK00003 Door assembly 27 XMK00109 Evaporator Coil Assembly 3977984 Wire shelf 19 3978014 Wire Shelf 27 F18WR60 SERIES XMK00003 Door assembly 27 XMK00109 Evaporator Coil Assembly 3978014 Wire shelf 27 F18WR70 SERIES XMK00004 Door assembly 32 XMK00109 Evaporator Coil Assembly 3977983 Wire shelf 32 F18WR79 SERIES XMK00001 Door assembly 19 XMK00003 Door assembly 27 XMK00108 Evaporator Coil Assembly 3977984 Wire Shelf 19 3978014 Wire Shelf
36. nk Refrigerant charges gas refrigerant 404A 16 oz 9 Delfield F18 Series Service and Installation Manual Condensing Unit Assembly 1 3 HORSE POWER Used F18DC60 amp 68 F18RC60 amp 68 MEDIUM DELFIELD COPELAND KEY PART PART 3526746 FJEM A034 IAA 244 DESCRIPTION 1 3 H P med condensing unit 3526750 JS25G1E IAA 908 welded compressor 040 0128 01 elay current 1 3 HORSE POWER Used F18FC43 LOW DELFIELD COPELAND KEY PART PART 3526710 M4YL 0035 IAA 201 DESCRIPTION 1 3 H P low condensing unit 014 0008 51 capacitor starting 071 7003 02 overload protector 3526749 AS13C1E IAA 908 welded compressor 040 C411 83 relay current 050 0259 07 motor fan morrill 066 0308 00 coil condenser 014 0038 04 capacitor starting 071 C100 38 overload protector 083 0131 00 blade fan 577 0430 01 receiver tank 050 0259 10 motor fan 066 223 00 coil condenser 3 rows 085 7031 01 control high pressure 083 0122 00 blade fan 077 C221 03 receiver tank Refrigerant charges gas refrigerant 404A 24 oz 1 2 HORSE POWER ae On F18RC72 82 amp 91 F18DC82 91 MEDIUM DELFIELD COPELAND KEY PART PART 3526731 FJEM 0051 CAA 244 DESCRIPTION 1 2 H P med condensing unit Refrigerant charges gas refrigerant 404 24 07 1 2 HORSE POWER Used On F18F062 LOW DELFIELD COPELAND KEY PART PART 3526711 FJAF A050 I
37. oing is exclusive and in lieu of all other war ranties whether written or oral express or implied This Warranty supersedes and excludes any prior oral or written representations or warranties Delfield expressly disclaims any implied warranties of merchantability fit ness for a particular purpose or compliance with any law treaty rule or regulation relating to the Motor Compressor and the full liability of Delfield for any breach of this war ranty will be as provided in this warranty Other than any applicable Delfield Standard One year Lim ited Warranty this Delfield Additional Four Year Protection Plan and any applicable Delfield Service Labor Contract the Original Purchaser agrees and acknowledges that no other warranties are offered or provided in connection with or for the Motor Compressor or any part thereof In no event will Delfield be liable for special incidental or con sequential damages or for damages in the nature of penalties For customer service call 800 733 8829 800 773 8821 Fax 989 773 3210 www delfield com 23 AUTHORIZED PARTS DEPOTS NORTH AMERICA Delfield has 14 conveniently located Parts Depots to ensure parts are handled promptly and accurately 1 The Delfield Company 980 South Isabella Road Mt Pleasant MI 48858 800 733 8829 989 773 7981 989 773 3210 FAX custom parts direct from Delfield 5 Contract Ice 2 A I S Commercial Parts amp Service 3 Appliance Ins
38. otor Compressor is inoperative due to defects in mate rial or factory workmanship as determined by Delfield in its sole judgement and discretion The Original Purchaser shall be responsible for returning the defective Motor Compressor to Delfield prepaid F O B at the address shown on the back cover of this manual The term Original Purchaser as used herein means that person firm association or corporation for whom the Unit was originally installed The term Motor Compressor as used herein does not include unit base air or water cooled condenser receiver electrical accessories such as relay capacitors refrigerant controls or condenser fan motor assembly This warranty does not cover labor charges incidental to the replacement of parts This warranty further does not include any equipment to which said condensing unit is connected such as cooling coils tempera ture controls or refrigerant metering devices This warranty shall be void if the Motor Compressor in Delfield s sole judge ment has been subjected to misuse neglect alteration or accident operated contrary to the recommendations specified by the Unit manufacturer repaired or altered by anyone other than Delfield in any way so as in Delfield s sole judgment to affect its quality or efficiency or if the serial number has been altered defaced or removed This Warranty does not apply to a Motor Compressor in any Unit that has been moved from the location where i
39. ration leak in a rail DANGER is extremely difficult and costly to repair In some cases it cannot be repaired at all Delfield F18 Series Service and Installation Manual Care and Cleaning Cleaning the cabinet The interior and exterior can be cleaned using soap and warm water If this is not sufficient try ammonia and water or non abrasive liquid cleaner When cleaning the exterior always rub with the grain of the stainless steel to avoid marring the fin ish Do not use an abrasive cleaner because it will scratch the stainless steel and plastic The interior of the cabinet should be cleaned daily with a non abrasive cleaner and a nonabrasive pad If necessary a mild abrasive may be used on the interior of the pans only Never use steel wool No drains are provided with rails after defrost ing water will accumulate in the rail This will need to be cleaned out thoroughly before restarting the rail as it will freeze and severely reduce the efficiency of the rail Cleaning the condenser In order to maintain proper refrigeration performance the condenser fins must be cleaned of dust dirt and A grease regularly It is recommended that this be done at least every three months If conditions NOTE such that the condenser is totally blocked in three months the frequency of cleaning should be increased Clean the condenser with a vacuum cleaner or stiff brush If extremely dirty a commercially available con
40. s and locations near stoves ovens and other pieces of cooking equipment It is recommended that the unit be installed no closer than 1 from any wall Do not install the unit near any combustible material or Note object affected by heat or moisture Leveling A level cabinet looks better and will perform better because the drain pan will drain properly the doors will line up with the frames properly and the cabinet will not be subject to undue strain A unit on legs will have an adjustable bullet foot on each leg adjust each for a level unit A unit on casters will not be adjustable Be sure the unit is on a level floor make necessary changes to the floor for proper level Lock all front casters to ensure the stability of the unit Plumbing Self contained models are standard with a condensate evaporator If for some reason a unit does not have a condensate evaporator or if the evaporator fails the unit s drain must have an outlet to an appropriate drainage area or container A refrigerated rail will have a 1 drain which will need to be run to an appropriate floor drain or container The drain will be stubbed to the bottom of the machine compartment Either run drain to a floor drain or add a valve to the base of the machine compartment and drain the rail to a container when convenient The LiquiTec option will NOT have a drain available Moisture collecting from improper drainage can create a slippery surface on
41. t was originally installed The addition of methyl chloride to the condensing unit or refrigeration system shall void this warranty 9 Delfield General Conditions Delfield shall not be liable in any manner for any default or delay in performance hereunder caused by or resulting from any contingency beyond Delfield s control including but not limited to war governmental restrictions or restraints strike lockouts injunctions fire flood acts of nature short or reduced supply of raw materials or discontinuance of any part or the Motor Compressor by the unit manufacturer Replacement of a defective Motor Compressor is limited to one 1 Motor Compressor by us during the four 4 year period Delfield shall replace the Motor Compressor at no charge This warranty does not give the Original Purchaser of the Motor Compressor the right to purchase a complete replace ment Motor Compressor of the same make or of another make It further does not permit the replacement to be made with a Motor Compressor of another kind unless authorized by Delfield In the event Delfield authorizes the Original Pur chaser to purchase a replacement Motor Compressor locally only the wholesale cost of the Motor Compressor is refund able Expressly excluded from this warranty are damages resulting from spoilage of goods Except as provided in any applicable Standard One Year Limited Warranty or applicable Service Labor Contract the foreg
42. tallation Service 4 Barker s Food Machinery 1816 West 26th Street Erie PA 16508 1149 800 332 3732 814 456 3732 814 452 4843 FAX serves MD NJ OH PA VA WV 6 E M C 0 Sales amp Distributors 14450 Ewing Ave S 100 Burnsville MN 55306 800 422 2823 952 894 4427 952 894 2164 FAX serves IA MN MT ND SD WI 9 Global Parts and Supplies 3909 St Timothy Lane St Ann MO 63074 800 972 7670 314 427 7477 314 427 8190 FAX serves AR IA IL KS KY MO NE OK TX NM LA 10 Hawkins Commercial Appl Serv 1336 Main Street Buffalo NY 14209 800 722 1252 716 884 7425 716 884 0410 FAX serves CT DC DE MA MD ME NH NJ NY PA RI VA VT WV 7 STOVE PARTS SUPPLY GCS SERVICE 2120 Solona St PO Box 14009 Fort Worth TX 76117 0009 1 800 433 1804 toll free 1 800 272 7358 fax serves AR LA NM OK TX 11 MicroDine Inc 5367 2nd Street Irwindale CA 91706 800 258 6999 626 960 9390 626 337 4541 FAX serves AZ CA HI NV OR 8 Garland Group 2920 N W 109th Avenue Miami FL 33172 305 994 9994 305 994 9992 FAX International parts depot 13 Southeastern Restaurant Services 3000 S Wyandot Englewood CO 80110 800 624 2117 303 7618861 FAX serves AZ CO KS NE NM OK UT WY 14 T M A 2200 Norcross Parkway Suite 210 Atlanta GA 30071 800 235 6516 770 446 6177 770 446 3157 FAX serves FL GA MS NC SC VA 2916 Sidco Drive Nashville TN 37204 615
43. the floor and a hazard A to employees It is the owner s and operator s responsibility to provide a container or outlet for CAUTION drainage Electrical connection Refer to the amperage data on pages 3 5 the serial tag your local code or the National Electrical Code to be sure the unit is connected to the proper power source A protected circuit of the correct voltage and amperage must be run for connection of the line cord or permanent connection of the unit Self contained units with a cord and plug have an ON OFF switch located directly behind the louvered panel covering the compressor section Simply turn the switch to ON to begin operation The power switch must be turned to OFF and the unit disconnected from the power source whenever performing service or maintenance functions DANGER Never operate the unit without the louvered panel in place If electrical receptacles are to be mounted in the unit s backsplash they must be wired independently from the existing unit wiring After turning the ON OFF switch to ON the unit s compressor will begin operating Delfield refrigerated bases are designed to maintain an operational temperature of 36 F to 40 F Temperature in the salad top and refrigerated rail opening is 33 F to 41 F with pans recessed 3 on a standard wrapped refrigerated rail or flush with the LiquiTec option at 86 F ambient room temperature Freezer bases are designed to maintain an operational temperat
44. thermostat Unit all other refrigeration units except those listed for XMK00107 This assembly is also used in conjunction with units listed for XMK00108 z Delfield F18 Series Service and Installation Manual Mullion Coil Assembly Freezers AIR DELFIELD Used on F18FC and F18FR PART DESCRIPTION NOTE Non numbered items with 1 not K00162 pan drip freezer mullion coil sold separately available only with com S AMK00004 back evap housing plete assembly XMK00061 00002 Side evap hsng LH A K00005 bracket fan motor blower coil 3516073 coil evap freezer 2194034 heater defrost AMK00000 front evap housing 2183310 harness coil freezer male 2162691 motor fan 115V 50 60 3516173 guard fan 6 38 dia lexan 3516172 blade fan 5 56 CCW lexan 9321353 screw 10x0 50 9321353 screw machine 10 9321238 screw 8x 75 9321131 screw 10 x 50 3516271 valve expansion 1 4 low R 4040A 2194046 control limit fan delay defrst not shown Need to order drip pan to get 1 s s drain not shown o co C a C Delfield For customer service call 800 733 8829 800 773 8821 Fax 989 773 3210 www delfield com 1 1 and Installation Manual F18 Series Service e 9 page 13 for part numbers 0 f t 2 c T Az T N ao gt p on cc lt Refrigerated Drawer
45. ure of O F Do not place hot pans on against the blue ABS liner Do not throw items into the storage area Failure to heed these recommendations could result in damage to the interior of the cabinet or to the blower coil Overloading the storage area restricting the air flow and continuous opening and closing of the doors and drawers will hamper the units ability to maintain operational temperature 6 For customer service call 800 733 8829 800 773 8821 Fax 989 773 3210 www delfield com Refrigerated rail units Product in the rail should be removed to the refrigerated base at the end of the day This allows you to turn the rail off at night to save energy and the rail will have time to defrost as needed It also helps maintain product quality The standard wrapped refrigerated NOTE units are controlled by the pressure control which is set to maintain the proper rail temperature an on off switch is also provided for the rail and is required to be shut off at night The rail switch shuts off the rail only With a LiquiTec rail a thermostat is provided to maintain rail temperature as well as the rail on off switch The LiquiTec rail is required to be shut off at night as well to allow for defrosting To ensure product quality in the rail it is recommended that product be rotated every four hours If adding any item to the unit be sure to keep in mind the location of the refrigeration lines on wrapped rail units A refrige
46. ushing nylon hinge pin Used on F18WR F18WC F18FC F18FR F18DR F18RC amp F18RR NOTE Indicate if door is left or right hinged when ordering DELFIELD PART DESCRIPTION XMK00118 complete louvered door assembly 14 XMK00120 complete louvered door assembly 18 SMK00507 front door 14 SMK00446 front door 18 3234073 hinge door top RH bottom LH 3234072 hinge door top LH bottom RH 3234391 hinge door L shaped 9321107 bushing nylon hinge pin SMK00771 bracket magnetic catch not shown 3234156 catch magnetic snap in not shown 3234191 strike steel not shown Used on F18SC F18SR F18MC F18MR F18DC F18DR F18RC amp F18RR DELFIELD PART DESCRIPTION NOT SHOWN Clip on style louver SMK00039 13 94 x 26 34 5 00041 17 94 26 34 Used F18FC F18WR C Delfield For customer service call 800 733 8829 800 773 8821 Fax 989 773 3210 www delfield com 1 5 F18 Series Service and Installation Manual PARTS LISTING For component parts Condensing units see page 8 Evaporator assy see pages 10 11 Door and drawer assy see 12 thru 15 F18DC SERIES STANDARD PARTS 1701000 Cutting Board Pin Cap 2183348 Cord plug assembly 2190154 On Off Switch 2193927 Low pressure control 3234266 Pan cover hinge right 3234282 Pan cover hinge B left 3234290 Support shelf plastic 3234392 Double hinge pan cover 3234645 Leg 35

Download Pdf Manuals

image

Related Search

Related Contents

COBY electronic CR-A129 User's Manual  SATA-IDE01 取扱説明書    Samsung โทรศัพท์มือถือ Trendy GT-C3560  Owner's Manual Bedienungsanleitung Mode d'emploi Manual de  Life Fitness 93RW User's Manual  Safety and Support Sécurité et support technique  Codeurs absolus Série de modèles CRD/S3 avec certification SIL2  ULTRA100 BS ULTRA100 GS BI-FUEL  User manual for M21/22, M51/52 in English  