Home
Agilent 66319B/D, 66321B/D Mobile Communications DC Sources
Contents
1. Average time required for the output voltage to begin to change following receipt of GPIB data is 4 ms with display disabled More detailed specifications at www agilent com find 66300 82 Application Specific DC Power Supplies tailored solutions for specific needs All models offer Fast output response technology e Programmable output response compensation e Advanced DSP based dynamic measurements e Current sinking for testing and calibrating charger circuitry Extensive protection features including broken sense lead detection GPIB Interface SCPI Standard Commands for Programmable Instruments VXIplug amp play drivers In addition the 66319B D and 66321B D high performance models offer e Output resistance programming positive and negative e Superior output stability with up to 6 meters of load leads Excellent transient voltage drop typically lt 30 mV Three current measurement ranges e NEW Additional advanced battery drain measurements CCDF long term battery drain The new and improved 66319B D and 66321B D high performance models are recommended for new automated test system platforms and for R amp D applications The 66309B D and the 66311B are available for those customers who need to replicate existing test platforms and who do not want to re engineer existing automated test system designs Mobile Communications DC Sources 40 100 W Continued Supplemental C
2. automation New capability makes it easy to automate battery current drain analysis The 14565B can be controlled from various programs and programming languages such as the Agilent Wireless Test Manager NI LabView Agilent VEE Micro soft Visual Basic Microsoft Excel and others Save valuable resource and time by automating time con suming repetitive tasks associated with characterizing battery current drains during real world operation like video streaming music down loads text messaging The 14565B Device Characterization Software with test automation reduces setup and test time reduces manual intervention and provides battery drain measurement and analysis Mobile Communications DC Sources Device Characterization Software Continued Key features For R amp D Fast and easy test setup e Digitize current waveforms Accurately log battery current drain measurements from 10 seconds to 1000 hours at 64 000 measurements per second New automation capability provides operational control from many test applications Test designs simulating different battery conditions with program mable output resistance Zoom capability for analyzing waveform anomalies Adjust markers for fast measure ments on digitized waveforms Easily document your test results Record test data to files for archive or analysis by other software packages For Repair e Compact design with multiple instrument functionality Fast a
3. points 4096 points 4096 points Sampling interval 15 us 15 us 15 us 15 us 15 us 15 us 31 200s 31 200s 31 200 s 31 200s 31 200 s 31 200 s Transient response time lt 35 ps lt 35 us lt 20 ps lt 20 us lt 100pus lt 100 ps Transient voltage dip 70 mV 70 mV 40 mV 40 mV 500 mV 650 mV typical with up to 15 feet 22 AWG wiring Programmable output resistance Range 40 MQ to 40mQto Q Q Programming accuracy 0 5 0 5 2 mQ 2 mQ Resolution 1mQ 1mQ More detailed specifications at www agilent com find 66300 81 Application Specific DC Power Supplies tailored solutions for specific needs device s main battery during testing Dual output models are recommend ed when you need to provide power as a replacement to your device s main battery and when you need to simulate the battery charger power Use one output to supply current to the battery charger input port and the second output to connect in place of the main battery which sinks current to simulate the main battery being charged Performs Like a Battery With their battery emulation features the Agilent 66319B D and 66321B D allow you to test your devices under the same power conditions that exist in actual use Emulating the battery is key when characterizing battery operating life and detecting early product failures These DC sources simulate the effects of internal resistance of the battery enabl
4. Application Specific DC Power Supplies tailored solutions for specific needs 66319B D 66321B D Overcome Battery Powered Device Testing Challenges Digital communications devices and digital battery powered devices present a unique testing challenge they draw rapid pulses of current By offering superior transient performance unmatched in the marketplace the Agilent Mobile Communications DC Sources dramatically reduce the transient voltage drop due to pulse loading characteristics of digital communi cations devices The Agilent Mobile Communications DC Sources enable you to maximize test throughput by minimizing test interruption due to false trigger of device low voltage shutdown Dynamic Measurement Capabilities The Agilent Mobile Communications DC Sources offer a built in advanced measurement system to accurately measure battery current drains when the device operates in differ ent modes such as talk mode active mode standby mode and off sleep mode Measurements made during these modes are critical for ensuring that your devices are operating properly and that you are getting the most out of the battery Simulate both Main Battery and Charger Single output models are recom mended when you need to provide power as a replacement to your Mobile Communications DC Sources 40 100 W Ideal for testing wireless and battery powered devices Several times improvement in measurement throughput over general purp
5. Supplies tailored solutions for specific needs Simplify test and analysis in R amp D or on the repair bench With the Agilent 14565B Device Characterization Software testing analyzing and troubleshooting wireless and battery powered devices is made simple The 14565B provides a graphical user interface that lets you easily control the Mobile Communications DC Sources It gives you access to the Mobile Communications DC Source s high powered measurement system and provides an oscilloscope like view of the voltage or current waveforms of the device under test The 14565B provides reference waveform save recall and provides oscilloscope like measurement and analysis including voltage and current waveform para meter measurements triggering markers zoom control and more By using the advanced capabilities built into the power supply you can spend more time testing and analyzing instead of configuring and reconfiguring multiple pieces of test equipment such as a current shunt oscilloscope current probe DMM and datalogger Continued Mobile Communications DC Sources 14565B Device Characterization Software Ideal fo r testing wireless and battery powered devices Converts Mobile Communications DC Source into a powerful bench top tool for R amp D and Repair Easy to use Graphical User Interface and analysis tools No programming required Power Supply output control Measure ment setup c
6. haracteristics Non warranted characteristics determined by design and useful in applying the product Continued Output Programming Response Time For 66332A The rise and fall time 10 90 and 90 10 of the output voltage is lt 2 ms 400 us in fast mode The output voltage change settles within 1 LSB 0 025 x full scale voltage of final value in lt 6 ms 2 ms in fast mode For 66311B 66321B D 66309B D output 1 66319B D output 1 The rise and fall time 10 90 and 90 10 of the output voltage is lt 200 us Measurement Time Average time to process query calculate measurement parameter and return data is 50 ms includes the default time of 30 ms for acquiring data and 20 ms data processing overhead GPIB Interface Capabilities IEEE 488 2 SCPI command set 6630A series programming capability not supported in 66309B D 66319B D 66321B D Software Driver e VXIPlug amp Play e IntuiLink Connectivity Software Application Notes Mobile Communications Device Testing AN 1310 5968 2424EN Evaluating Battery Run down Performance Using the Agilent 66319D or 66321D with Option 053 14565A Device Characterization Software AN 1427 5988 8157EN Input power at worst case conditions full load 100 Vac mains For 66311B 66321B D 1 7 A 125 W For 66309B D 66319B D 2 A 170 W For 66332A 3 5 A 250 W Regulatory Compliance Complies with EMC directive 89 336 EEC ISM 1B Warranty Peri
7. ing them to emulate the operation of various battery types or batteries in different charge states Plus these DC sources can simulate negative resistance so that you can compensate for voltage drop due to wiring in a fixture Feature Summary Agilent has designed in the capability and flexibility that is required for accurately testing today s communi cations devices as well as your next generation designs for cell phones formats include 3G cdma2000 WCDMA CDMA TDMA GSM PCS DECT TETRA PHS NADC PDAs Bluetooth enabled devices and Wireless LAN access devices Mobile Communications DC Sources 40 100 W Continued S pec ifications 66309B D 66311B 66319B D 66321B D 66332A 66332A at 0 to 55 C unless ao Uis otherwise specified He rder Voltmeter input 66309D 66319D and 66321D only Input range 25 to 25 to 25 to 25 Vdc 25 Vdc 25Vde DC readback accuracy 0 04 0 04 0 04 at 25 C 5 C 5 mV 5 mV 5 mV AC DC readback accuracy 1 1 1 at 25 C 5 C with DC plus 5 mV 5 mV 5 mV a sinewave input gt 25 mV rms 60 Hzto 60 Hzto 60 Hzto 10 kHz 10 kHz 10 kHz Auxilary output 66309B D and 66319B D Output ratings Voltage 0to12V 0 to 12V Current Oto15A 0to1 5A Programming accuracy Voltage 0 2 0 2 40 mV 40 mV Cur
8. nd easy test setup e Graphical user software no programming required Dual DC outputs for replacing the main battery and the power adapter charger power source Electronic load for testing the battery charger circuitry e Programmable soft limits to protect against incorrect voltage settings Ordering Information 14565B Device Characterization with Battery Drain Analysis amp Test Automation 14565U Device Characterization Software Upgrade provides upgrade from 14565A to 14565B Software Note Battery Drain Analysis means Data Logging and CCDF measurements These capabilities require models 66319B 66319D 66321B or 66321D with version A 03 00 firmware or higher and 14565B or 14565A software version 3 01 or higher More detailed specifications at www agilent com find 14565B 87
9. od One year Size For 66309B D 66311B 66319B D 66321B D 212 8 mm W x 88 1 mm H x 435 mm D 8 4 in x 3 5 in x 17 18 in For 66332A 425 5 mm W x 88 1 mm H x 364 4 mm D 16 8 in x 3 5 in x 14 3 in Weight For 66309B D 66311B 66319B D 66321B D 9 07 kg 20 lb net 11 1 kg 24 5 lb shipping For 66332A 12 7 kg 28 1b net 15 0 kg 33 lb shipping Using Battery Drain Analysis to Improve Mobile Device Operating Time 5988 7772EN Current Drain Analysis Enhances WLAN Network Card Design and Test AN 1468 5989 0565EN More detailed specifications at www agilent com find 66300 83 Application Specific DC Power Supplies tailored solutions for specific needs Mobile Communications DC Sources 40 100 W Continued Ordering Information Accessories n 1494 0060 Rack Slide Kit Opt 100 87 to 106 Vac 47 to 63 Hz Opt1CM Rack mount kit 66309B D 663324 only Gan Opt 120 104 to 127 Vac 47 to 63 Hz 66311B 66319B D 66321B D l Opt 220 191 to 233 Vac 47 to 63 Hz p n 5062 3972 66332A p n 5062 1912 E3663AC Support rails for i it wi Agilent rack cabinets Opt 230 207 to 253 Vac 47 to 63 Hz Opt 1CP Rack mount Kit with Handles 8 p n 5062 3975 66332A only 14565B Device Characterization Opt 004 Make Hi Compensation Mode A as default setting Opt AXS Rack mount Kit for side by side with Battery Drain Analysis amp Test mounting N A for 66332A Locking Automation Opt 007 Extra 5 pin output connect
10. ontrol Waveform Capture Mode Zoom capability Oscilloscope like view of battery current profiles gt Peak current Talk mode Standby mode Off mode duai Measurements CATURE angle rae fas 37130 vias Mn 310 3090mA Y2 403 0800n ox 126728 41 4963 For Help press F1 SIMULATION A 02 00 Calculated Markers for measurements fast analysts Data Logging Mode Oupa Vota f j 0 000V 0 00004 o ims Nekase Accuiien Parod usw EN EES Hiemanng Peroa _ Minimum Current Envelope fs Average Current Cumert Grech Tyee F tin Gry tard Fox Helo prose PA Eramo kee More detailed specifications at www agilent com find 14565B 86 Application Specific DC Power Supplies tailored solutions for specific needs When coupled with the 66319B D or the 66321B D the 14565B also provides Battery Drain Analysis capabilities More than just measur ing battery run time Battery Drain Analysis allows you to characterize current out of the battery and make tradeoffs in design that impact the current drain and battery life By providing CCDF measurements and long term battery drain data logging the 14565B and 66319 21 provide a complete solution for analyzing current drain so that you can optimize your device designs to achieve maximum battery run time Save time with test
11. ors E 3 A Kit p n 5061 9694 Flange Kit f Doni 2 x p n 0360 2604 p n 5062 3974 14565U Device Characterization Opt 020 Front panel Binding Posts Opt0L1 Full documentation on ee perane nes upgrade 66332A only CD ROM and printed standard irom 14569A to 14565B Software A o panel binding posts aa On package Note Battery Drain Analysis means Ly pt L2 Extra copy of standard Data Logging and CCDF measurements Opt 521 Solid State Relays printed documentation package These capabilities require models 66309B D 66319B D Opt 0B0 Full documentation on 66319B 66319D 66321B or 66321D Opt AYK No Solid State Relays CD ROM only with version A 03 00 firmware or higher 66309B D 66319B D Opt 0B3 Service manual and 14565B or 14565A software version Opt 760 Isolation and Reversal 3 01 or higher Relays 66332A only Opt 8ZJ Delete feet aca Agilent Models 66309B D 66311B 66319B D 66321B D Support rails required More detailed specifications at www agilent com find 66300 84 Application Specific DC Power Supplies tailored solutions for specific needs Mobile Communications DC Sources 40 100 W Continued Agilent Models 66332A Top lt M 364 4mm gt 14 3 Terminal Strip Detail Output 2 amp 3 S S L olll Screw Size M35 x 0 6 y y w e D ce E C C F XS _ _ gt A Si Rear More detailed specifications at www agilent com find 66300 85 Application Specific DC Power
12. ose DC sources Superior output transient performance with short or long load leads up to 6 meters Dynamic measurement system for accurate battery current drain measurement New easy to use Graphical User Interface and analysis tools for bench top use S pec i f ications 66309B D 66311B 66319B D 66321B D 66332A 66332A at 0 hi 55 C unless A Order otherwise specified Option Number of outputs 2 1 2 1 1 1 GPIB Yes Yes Yes Yes Yes Yes Output ratings Voltage 0to15V Oto15V Oto1l5V Oto15V Oto20V 0to30V Current 0to3A 0to3A 0to3A 0to3A 0to5A 0 to 3 3 A Peak current for up to 7 ms 5A 5A 5A 5A 5A 33A Programming accuracy at 25 C 5 C of setting plus fixed Voltage 0 05 10mV 10 mV 10 mV 10 mV 10 mV 15 mV Current 0 05 1 33 mA 1 33 mA 1 33 mA 1 33mA 2mA 2mA Ripple and Noise 20 Hz to 20 MHz Voltage ms 1mV 1 mV 1 mV 1 mV 0 3 mV 0 5 mV peak to peak 6 mV 6 mV 6 mV 6 mV 3 mV 5 mV Current rms 2mA 2mA 2mA 2mA 2mA 2mA DC measurement accuracy Voltage 0 03 5mV 5 mV 5 mV 5 mV 3 mV 5 mV 20 mA to rated current 0 2 0 5 mA 0 5 mA 0 5 mA 0 5 mA 20 mA to rated current 0 2 1 1 mA 1 1 mA 1 1 mA 1 1 mA 3Ato 5A 0 2 05mA 05mA 1Ato 1A 01 0 2 mA 0 2 mA 20 mA to 20 mA range 0 1 2 5 pA 2 5 pA 2 5 pA 2 5 pA 2 5 pA 2 5 pA Dynamic measurement system Buffer size 4096 points 4096 points 4096 points 4096
13. rent 0 2 0 2 4 5 mA 4 5 mA DC measurement accuracy Voltage 0 2 0 2 15 mV 15 mV Current 0 2 0 2 3 mA 3 mA Ripple and Noise 20 Hz to 20 MHz Voltage rms 1mV 1 mV peak to peak 6 mV 6 mV Current rms 2mA 2 mA Notes 1 66332A also has RS 232 interface Applies with current detector set to DC 3 Time for the output voltage to recover to within 20 mV of final value after 0 1 to 1 5 A load change in high capacitance compensation range Time for the output voltage to recover to within 20 mV or 0 1 of the voltage rating of the unit following a change in load current of up to 50 of the output current rating SUCHE MMe tacit Non warranted characteristics determined by design and useful in applying the product DC Floating Voltage Output terminals can be floated up to 50 Vdc maximum from chassis ground 240 Vdc for 66332A Remote Sensing Voltage Drop For 66332A Up to 2 V can be dropped in each load lead Add 2 mV to the load regulation specification for each 1 V drop in the positive output lead For 66309B D 66311B Up to 4 V can be dropped in each load lead Add 2 mV to the load regulation specification for each 1 V drop in the positive output lead For 66319B D main output 66321B D main output Up to 3 V total can be dropped in both load leads For 66319B D auxiliary output 66321B D auxiliary output Up to 4 V total can be dropped in both load leads Command Processing Time