Home
Service Manual
Contents
1. Faulty wiring Test and Remedy Check coil s and contacts of contactor s Replace if necessary Check wiring to contactor s Replace if necessary PROBLEM Skillet fails to heat with pilot light off power switch must be on and thermostat set Probable Cause Main power to skillet is off Defective power switch Defective thermostat Defective high limit thermostat Test and Remedy Check incoming power at terminal block With power source off remove wiring from switch and test for continuity Or with wiring connected and unit on check for voltage across terminals of switch Voltage indicates an open circuit Replace switch if necessary Shut the unit off and disconnect wiring from thermostat Check for continuity of thermostat An open circuit while in the ON position indicates a faulty thermostat Or with thermostat connected and unit on check for voltage across thermostat Voltage indicates an open circuit indicating a faulty thermostat Repeat above procedure used for defective thermostat PROBLEM Skillet fails to reach maximum 425 F at 10 setting Probable Cause Defective or improperly adjusted thermostat Defective safety thermostat Test and Remedy As unit shuts off early check for voltage across thermostat terminals If there is voltage across terminals re calibrate or replace thermostat Repeat above procedure used for defective thermostat PROBLEM Skillet has uneven heat over pan surface
2. Probable Cause Defective contactor Defective heating element block Faulty wiring Uneven torquing of aluminum heating blocks Test and Remedy Check contactors for burned out contacts and replace if required Check for continuity between element terminals and from terminals to ground Either an open circuit between terminals or a short to ground indicates a faulty element Replace if necessary Inspect condition of wires and connections to elements and contactors Repair if necessary Follow element block torquing procedure MODEL SET 10 SKILLET WIRING DIAGRAM 3 ELEMENTS 2400 2300 e on 3000 230V ea mor TENPERATUNE Wo AGH LIMIT THERMOSTAT CONTROL i o IMERMOSTAT lt ON OFF SWITCH CONIACTOR WHITE 208 360 220 380 240 415 V VOLTS KW PH AMPS JLLEMENTS Saale OV ea a000w 230V e9 TAST shk ERE ESL kg fy E2 ynd EB i PA PILOT TEMPERATURE HOH LIMIT THERMOSTAT CONTROL THEAMOSTAT ON OFF SMICH CONTACTOR 208 240 V THREE PHASE aM SINGLE PHASE AMPS VOLTS
3. Repair Manual Table Top Electric Skillet Model SET 10 128S Cleveland Range Inc CANADA 8231 KeeleSt Concord Ontario Canada L4K 121 Phone 416 660 4747 FAX 416 660 4432 Toll Free 1 800 387 3562 in Canada only UNITED STATES 1333 East 179th St Cleveland Ohio 44110 Phone 216 481 1900 Telex 98 0546 FAX 216 481 3782 Toll Free 1 800 782 0040 in U S A only SKI 01 MODEL SET 10 SKILLET OPERATING CONTROLS AND INDICATORS For your better understanding and confidence the following explanation of the control system used on these skillets is offered Item No Description Function 5 6 Semi Tilt Arm and Knob Control While skillet is in a tilted position push knob in and Housing Dwg rotate This will keep the skillet in a semi tilted position when lowered 13 ON OFF Toggle Switch Control Controls electric power to the skillet Housing Dwg 15 Pilot Light The pilot light cycles on and off indicating Control Housing Dwg power to the elements controlled by the thermostat 20 Thermostat Control Knob Control Housing Dwg This control knob allows the operator to select 5 6 Tilting Handle and Knob Skillet various heat increments for operating the skillet Bottom Dwg This handle allows the operator to manually tilt the skillet 03 MODEL SET 10 SKILLET BOTTOM Tighten to 11 ft Ib amp Apply Loctite Item No Part No Description Ah 1 SK50019 Washer Spherica
4. l 16 2 FA21024 Nut 5 16 18 16 3 SK00018 Element Block Assembly 3 4 SK50028 Thermostat High Limit 5759F 302 C 1 6 KE50803 Handle 1 Use only replacement parts which are factory supplied as to preserve the certification of Underwriters Laboratories American Gas Association Canadian Standards Association or Canadian Gas Association as applicable The use of other than factory supplied replacement pans will void the warranty 04 MODEL SET 10 SKILLET CONTROL HOUSING Item No Part No Description Qty 1 FA11135 Screw Cover 10 24 x 1 2 1 2 SK50038 Spring 1 3 SK50037 Washer 1 4 FA95013 Pin 2 5 SK00025 Semi Tilt Arm 1 6 KE50442 Knob 1 7 FA11501 Screw Knob 1 8 SK50054 Terminal Block End Section 1 9 SK50055 Terminal Block 3 10 KE50749 Contactor 208 240V 1 11 SK50039 Bronze Trunnion Bearing 2 12 SK50050 Console Cover 1 13 SK50056 Switch Toggle ON OFF DPST 1 14 SK50062 Rubber Boot 1 15 SK50057 Pilot Light 1 16 SK00028 Thermostat 1 17 SK00031 Bezel 1 18 FA10135 Screw Bezel 6 32 x1 1 4 2 19 FA10140 Screw Termostat 6 32 x 5 8 2 20 SK50060 Knob Thermostat 1 21 SK50047 Trunnion Lock Collar 1 Use only replacement parts which are factory supplied as to preserve the certification of Underwriters Laboratories American Gas Association Canadian Standards Association or Canadian Gas Association as applicable The use of other than factory supplied replacement pans will void the warranty Item No PartNo Descripti
5. on Qty KETTLE AND SKILLET FAUCET 10 KE51403 Double Pantry Control Valve 1 Item No PartNo Description Qty incl Item No 1 2 3 1 SE50020 Hot Water Stem Assy 1 11 N A Old Style Single Pantry 2 SE50021 Cold Water Stem Assy 1 3 SE50022 Yoke Connection Kit 1 eas O N Ger 4 FA00016 0 Ring 1 5 6 7 5 FA95022 Retaining Ring 1 N A Old Style Double Pantry 6 SE50064 Spout Nut 1 Control Valve please order 7 see chart 3 4 spout please see 3 4 1 Item No 4 5 6 7 10 spout chart below A 8 N A 3 4 spout with Aerator please 1 le NA A viid LU order Item No 4 5 6 7 13 FA00115 g Ring 2 9 KE51401 Single Pantry Control Valve 1 14 SE50061 Adapter to adapt new styl 1 incl Item No 2 apter to adapt new style spout to old style control valve A B Part No 4 fe KE50833 10 fo KES0832 8 Bet _ KE50831 24 fo _ KES0827 20 9 KES0826 1212 9 gn KES0825 Use only replacement pans which are factory supplied as to preserve the certification of Underwriters Laboratories American Gas Association Canadian tandards Association or Canadian Gas Association as applicable The use of other than factory supplied replacement parts will void the warranty TABLE TOP ELECTRIC SKILLET SERVICING GUIDE This section contains servicing information intended for use by Authorized Service Personnel A C D PROBLEM Skillet fails to heat with pilot light on Probable Cause Faulty contactor s
Download Pdf Manuals
Related Search
Related Contents
KMD-201AA SERVICE MANUAL TROIS取扱説明書をダウンロード[PDF 16.3MB] Canada Installation Manual Wireless Movement Sensor - Super-Sail luiz fernando cunha grenier - Prefeitura Municipal de Telêmaco Borba Mod: FPE-5N Local Radiowave Protective Volumetric Detector Wayne-Dalton 8000 Garage Door Opener User Manual Project Nemesys Deliverable D2.2 Honeydroid Copyright Disclaimer CE Declaration Canadian Department of Copyright © All rights reserved.