Home

Sortis Ice Fountain Cut Sheets (2-23

image

Contents

1. LEVEL DATE DESCRIPTION REVISED A 2 23 11 ORIGINAL AWP SORTIS ICE FOUNTAIN EQUIPMENT CRITERIA EQUIPMENT QUANTITY DESCRIPTION VOLTAGE PHASE AMPS ICE MACHINE 1 Follett 400 115 1 11 BOWL amp STAND 1 Custom Carved Stone TBD ICE SENSOR 1 Automation Direct Eaton 1351E 6534 Stock MICRO CONNECTOR CABLE 1 Automation Direct Eaton ZCSAS5A5CY2205 TIMING RELAY 2 McMaster Carr 7399K14 24 240 VAC POWER RELAY 2 Hagameyer S87R11A2B1D1120 120 VAC Power Relay Stock LIGHT 1 Visual Lighting Technologies BLUX 0103 F25 0 NX 10 Degree 12 1 1 LIGHT DRIVER 1 Visual Lighting Technologies LED 18 350 120 D 120 Input MAIN TITLE SORTIS HOTEL DRAWN SUB TITLE ICE FOUNTAIN EQUIPMENT CRITERIA DRAW DATE 2 23 11 FILE NAME Sortis Ice Fountain Cut Sheet dwg CHECKED BY The leaders in Design and Manufacture SCALE of Quality Stainless Steel Spas Pools and Aquatic Vessels JOB NO 3488 www bradfordproducts com 1 800 438 1669 TER CUSTOMER SYSA PANAMA 710 Sunnyvale Drive Wilmington NC 28412 OPAN NO Sf THIS DRAWING IS THE SOLE PROPERTY OF BRADFORD AG V PRODUCTS LLC MAY NOT TRANSMITTED OR 1 OF 1 Products L L C REPRODUCED WITHOUT WRITTEN PERMISSION FROM BRADFORD PRODUCTS T400A W MCD400A W R400A W MFD400A W D400A W Icemakers vxnlollstice
2. WHITE YELLOW CONTROL 00 gt 20 o COMPRESSOR FAN DRIVE NONWINOO OVA Ave pwr RESET 20m wR Ost Ose COMPRESSOR SWITCH 27 BIN SIGNAL em FROM DISPENSER BIN T STAT JUNCTION BOX MCD400A WVS series blk wire is on 24V Refrigeration system all models All service on refrigeration systems must be performed in accordance with all federal state and local laws It is the responsibility of the technician to ensure that these requirements are met Recharging icemaker to other than factory specifications will void the warranty R404A icemaker charge specifications Model Charge Refrigerant type T400A MCD400A MFD400A R400A D400A air cooled 190z 539g R404A T400W MCD400W MFD400W R400W D400W water cooled 902 255g R404A Refrigerant replacement requirements 1 Non contaminated refrigerant removed from any Follett refrigeration system can be recycled and returned to the same system after completing repairs Recycled refrigerant must be stored in a clean approved storage container If additional refrigerant is required virgin or reclaimed refrigerant that meets ARI standard 700 88 must be used 2 In the event of system contamination
3. 34 Air cooled icemakers Part 502724 501187 502116 501986 500504 00141440 502079 502078 502220 502221 502726 502727 502732 501966 502729 502730 501191 500474 500672 501188 502782 502731 502728 500376 502920 501820 502734 502924 502925 00109728 502830 502698 Description Drier Condenser coil A C Water sensor Reservoir mounting bracket Float valve amp reservoir Drain kit evaporator Evaporator see page 32 and 33 for complete breakdown Tubing polypropylene reservoir supply sold by foot Fitting plastic float valve includes sleeve amp stem Compression nozzle with double drain Compression nozzle with single drain Valve expansion thermal Drain pan evaporator High pressure cutout Tubing evaporator drain 3 4 19mm ID x 1 26mm OD sold by the foot Mounting bracket gearbox Gearbox amp motor assembly 115V 60Hz Tubing plastic food grade 1 2 18mm ID sold by foot Fan blade Motor fan 115V 60 2 Bracket fan motor Overload compressor 115V 60Hz Compressor 115V 60Hz Base L400A Strainer water threaded connections Strainer push in connections Shroud condenser coil Water inlet amp drain assembly brass Water inlet fitting plastic Water inlet elbow plastic Drain fitting plastic Jacket insulation TXV Bracket ice tube entry 35 Order parts online www follettice com Reference 1 2 Not shown
4. INPUT POWER WATER G GRD SENSOR e PWR RESET 5 GRD L1 pr u W WHITE T O EAN CONTROL BLACK s BOARD Q BLACK WHITE 12 12 eg Qum 2 2 COMPRESSOR TS 1 i 4 892 Ose RED 1 DRIVE I BLACK i 5 BE RED REEL REG HIGH PRESSURE SAFETY SWITCH H COMPRESSOR WHITE 1 WY WHITE WHITE START A RED BIN SIGNAL 5 i YELLOW RUN FROM DISPENSER BIN T STAT 3 WN i JUNCTION BOX TOL MCD400A WVS series i blk wire is on 24V Diagnostic sequence Stage 10 If the water level in the float reservoir drops to an unacceptable level the WTR LED will go out shutting the icemaker off Also the BT LED will come on preventing the icemaker from restarting for twenty minutes If water is restored the WTR LED will come back on and flash to alert the technician that water to icemaker has been lost The icemaker will then restart at the end of the 20 minute time delay The flashing WTR LED can be cleared by pressing the reset button INPUT POWER WATER G GRD SENSOR B Ww WHITE I BLACK BLACK WHITE aa 97 12 RED BLACK BLACK 1 Ly ORANGE BLACK HIGH PRESSURE SAFETY SWITCH GEARMOTOR 4 2
5. 7 mA or 24 VDC 38 Plug in panel mount relay is our most versatile relay It lets you switch between seven timing ranges and eight timing functions on delay delay on make interval repeat cycle two types switch off initiated interval delay on break switch on initiated interval single shot and two types of on off delay LCD bar graph displays the time remaining elay is 11 pin circular pin style Switches one circuit on or off SPDT Control voltage is 24 240 VAC 12 240 VDC Power consumption is 167 mA and reset time is 500 mS Fits a standard 1 77 x 1 77 Yc DIN panel cutout when used with the mounting bracket sold separately hardware included 2 59 s Miniature PX Plug In Bata Plug Panel Mount i Re 0 85 Relay 1897 Sockets sold separately below are DIN rail and surface mountable have two 0 165 mounting holes hardware not included See page 896 for more socket information Each 7339K7 56 11 6963 14 128 50 Miniature Plug In Relay Plug In P anel Mount Relay DIN Rail Mount Long Life Relays with Multiple Timing Functions A slim profile and mounting adapters let you DIN rail or surface mount to save space in crowded enclosures hardware included Re lays switch between on delay delay on make interval repeat cycle switch off initiated interval delay on break and switch on initiated interval single shot functions
6. 20 ft 6m Factory approval required for longer runs Run tube without dips One continuous length of tube no splices Minimum radius of bends in tube 6 153mm inside radius Maximum number of bends 6 Insulation on entire run of ice tube Procedure If installing MCD series icemaker refer to additional connection specifications for Vision series ice and beverage dispensers instructions below 2 Select side rear or top knockout in icemaker cabinet for tube entrance 3 Install supplied grommet in knockout 4 Remove icemaker top panel 5 Install supplied insulation on entire length of tube 6 7 8 Run insulated tube without dips between icemaker and dispenser and secure in place Cut insulation off tube where tube enters grommet Slide end of tube without insulation through grommet and run to evaporator port 9 Cuttube to that length 10 Install a section of insulation on tube from grommet to evaporator port 11 Slip supplied hose clamp over free end of tube 12 Pull insulation back from free end of tube 13 Push tube on evaporator port 14 Position clamp behind lip on evaporator port and tighten clamp Correct installation Incorrect installation Length of run no more than 20 ft 6m Dips in tube where water can collect Tube run continuously from icemaker to Splice or tight bend that restricts ice flow dispenser Uninsulated tube that results in wet ice and Insulation on entire
7. 4 iQ BLACK fae m WHITE WHITE START ES BIN SIGNAL YELLOW RUN FROM DISPENSER AAT JUNCTION BOX BINESTAT 1 TOL MCD400A WVS series i blk wire is on 24V Normal operation Stage 6 When the dwell time of 20 minutes has expired the B T LED goes off The icemaker will go through the normal start up sequence when the bin level control signals the control board for ice The WTR LED will remain on as long as the water sensor in the float reservoir senses water 3 Pwr INPUT POWER WATER G SENSOR RESET B GRD L1 DR 1 FAN CONTROL 2 L2 BOARD v BLACK WHITE L2 O eno 12 O wR RED z9 B T ms BLACK n BLACK COMPRESSOR FAN SOR DRIVE eS RED ORANGE 5 L BLACK H ES as BLACK 2 mz 5 gt HIGH PRESSURE Q SAFETY SWITCH S ltr COMPRESSOR BUR eae pen eG WHITE GEARMOTOR w 4 2 BLACK G WHITE WHHTE 01 START A i agp 0 0 BIN SIGNAL i YELLOW RUN FROM DISPENSER 4 3 JUNCTION BOX BIN ESIAL Diagnostic sequence Stage 7 MCD400A WVS series blk wire is on 24V The 20 minute error LED 20M is on i
8. 5 mA 0 05 sec 300 hrs 69695K51m 74 24 1 2 sec 300 hrs 69695K72m 94 06 2 mA 0 05 sec 12 sec 69695 74 90 30 2 3 sec 12 min 69695K73 90 30 8 mA 0 sec 60 sec 70185K91 280 86 128 mA 0 sec 240 70185 92 280 86 128 mA 0 min 30 min 70185K93 280 86 128 mA 0 min 60 min 70185K94 280 86 4 07 6 60 8 82 4 76 2 s Plug In Plug Panel Mount Rel a Relay Total Timing Range Each Plug In 0 05 sec 999 min 6964K2 70 69 Plug In Panel M ount Relay 0 05 sec 999 hours 6964K3 85 08 Panel Mount Bracket for Plug In Panel Mount Relay 6963K22 8 82 Socket for Both Relays 7122K21 6 89 35 mm DIN Rail 1 m Lg 8961K15 4 76 Long Life Relays with Multiple Timing Functions Versatile and long lasting these relays have solid state outputs Rated 3 amps 9 250 Mechanical life is 10 million cycles UL rec ognized and CSA certified Miniature plug in relay is small enough for tight spaces You ll get an adjustable timing range between 0 1 seconds and 10 minutes and three operating modes on delay delay on make interval and re peat cycle Switches four circuits on or off QRDT and has 14 quick disconnect terminals Reset time is 100 mS Please specify control voltage power consumption 100 120 VAC 117 mA 200 230
9. Voltage Rating 320 V 24 VDC for LED plugs 600 V Current Rating 4A 4 pin 10A 5 pin 8 Contact Resistance 5 mO maximum 5 mQ maximum Isolation Resistance 1000 MO minimum 1000 MO minimum Protection IP67 NEMA 6P IP68 Temperature Range 25 to 90 20 to 105 C Cable Diameter 3 C 3 Conductor 22 AWG PVC 4 C 0 21 inch 5 3 mm 5 C 0 20 inch 5 1 mm 16AWG 4 0 42 inch 97 5 0 50 inch 12 7 mm Bend Radius Volume 13 e19 54 Sensors Minimum recommended bend radius is 12X cable diameter 0 CSDS4A4CY2205 CSAS4F4CY2205 Q CSAS5A5CY2202 0 CSMSAA4CY1602 0 5 55 5 1602 1 800 633 0405 Relays with Timing Function For information about electrical switches see page 839 For information about timing functions see page 897 Panel Mount Relays with Timing Function Stop fumbling with hard to set relays that don t even fit your panel Panel mount these relays for a finished look All have an indicating light Reset Control Power time is 100 mS unless noted Voltage Consump Compact and standard relays switch two circuits VAC tion Timing Range Each on or off and are rated 5 amps 9 250 Compact 8 Circular P in except 69695K51 which is rated 5 amps 240 On Delay 100 120 25 0 5 sec 5 sec 696
10. Corrective action lcemaker runs for short period of time and shuts Kink in ice transport tube Bin level control remains in closed position k Eliminate kink and check that tube routing complies with Follett icemaker installation manual runs Failed fan motor causes high pressure cut out to open down on torque 3 Ice transport tube ruptured internally 2 Adjust or replace control error 4 Worn evaporator bearings 3 Replace complete run of ice transport 5 Faulty gearmotor start relay Icemaker tube System status torques out within 5 seconds of start up 4 Inspect bearings for roughness or 20M or 2nd LED 6 Torque out occurs when storage bin fills binding and replace if necessary are lit to capacity 5 Replace gearmotor start relay 6 Ensure that ice contacts bin thermostat before backing ice up in transport tube Reference dispenser manual for proper thermostat and ice tube mounting 7 Evaporator is iced 1 Gearmotor running but no output rotation 1 Check for broken gearmotor output up on the outside 2 Float reservoir empty shaft or damaged gearbox No ice production 3 Air bubble in water supply line Water in 2 Check for defective water sensor reservoir but not in evaporator water OK WTR LED remains on System status even when float empty or probe compressor removed from water gearmotor and fan 3 Purge air from line motor running 8 Compressor cy
11. 118 Alternative Bottom Feed can To order add BF to the part number INPUT BLACK LED TOTAL LENGTH 390mm 18AWG INPUT WHITE LED TOTAL LENGTH 390mm 18AWG OUTPUT BLACK LED TOTAL LENGTH 390mm 18 OUTPUT RED LED TOTAL LENGTH 390mm 18AWG 1 7 J mrm LU es www lightechinc com Typical Mounting of Bottom Feed On Junction Box SSSSSSS SI 72722 THR LED 500mA max 3m 118 From 3 to 12 leds in series WHITE WIRE max 3m 118 LIC HI www lightechinc com Declaration of Conformity for electromagnetic interference This equipment has been tested and found to comply with the limits for rf lighting devices pursuant to part 18 of the FCC rules section 18 309 C consumer These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications There is no guarantee that interference will not occur in a particular installation Please note that TRIAC dimmers are permitted by the FCC to generate relatively high levels of interference compared to this product If a problem is encountered with interference from such a dimmer the use of the alternative reverse phase con
12. 6513 6 foot cable 300V Pre wired 6 ft 1 8 m 1351E 6543 Solig state relay 4 pin Micro AC connector 240 VAC VDC CSAS4F4CY2202 USASAFAUYZZUS 1351E 6503 4 pin Mini connector CSMS4A4CY1602 TSMS4A4TY 1606 1351E 6514 64001 cable 300V Pre wired 6 ft 1 8 m 1351E 6504 5 pin Mini connector Note Ranges based on 90 reflectance white card for diffuse reflective sensors CSMSSASCY1602 USMSSASCY 1606 Wiring Diagrams Pin numbers are for reference only Rely on pin location when wiring haracteristic cu rve chart Operating Models Cable Models Mini Connector Models Micro and Euro Micro Connector Models Voltage Face View Male Shown Face View Male Shown RANGE cm Diffuse 0 254 2 54 254 254 2540 BR Loadh V 1009 10 40 VDC Ww 2a PNP NPN V Load Lead DO OX 2 D BK Toad D V o BU Load 100 z 12 240 VDC x ur Diffuse 23 Isolated AC DC Isolated AC DC 24 240 VAC 11 Output Output e WH Isolated Solid Stat Out 2 o Relay Bk AC DC Output AD 09 2 L2 BU L2 12 9 O 39 11 Out X 4 D7 12 240 VDC pitfuse L1 N O N C
13. FH cH cH Front view air cooled Satellite fill 12 875 1 327mm 8 375 4 213mm 4 75 1 121 2 25 57mm 1 875 48mm Side view air cooled and water cooled top mount and Satellite fill icemaker and any adjacent equipment maximum clearance between discharge and air Back view air cooled top mount Front view water cooled Satellite fill Back view water cooled top mount e 1 875 48mm 700 178mm Icemaker plug configuration NEMA 5 20 22 75 578mm 4 20 75 527mm 2 4 1700 432 Satellite fill air cooled units only 3 4 MPT drain 3 8 OD push in water inlet Electrical cord D 3 8 FPT condenser inlet E 3 8 FPT condenser drain F Bin signal cord 7 Installation Icemaker performance is very sensitive to the quality of installation To ensure proper performance ease of service and warranty coverage it is critical that you follow t
14. 01 1 10 100 1000 Load Out Out Load Load Out aj RANGE inches Ea EM COM 20 oO 1204427 90 Reflectance White Card Load N C Out 232 L1 9 N 0 12 dimension chart 7 Connect load to appropriate output for either sinking or sourcing operation 4 3 Ta 5 5 1 H Cables and accessories Cables and accessories start 2 on page 19 65 3 4 0 50 100 150 200 250 300 350 Distance cm Volume 13 e19 50 Sensors 1 800 633 0405 E T N Enhanced 50 Series Photoelectric Cutler Hammer Part Number Enhanced 50 Series Cables Selection Chart Description Sensors Connector Cables Gauge Pin Out Diagram CSDS4A4CY2202 DC Euro Micro connector cable for quick disconnect photoelectri straight female C 4 pin 4 wire PVC 6 feet 2 meter length sensors CSDS4A4CY2205 straight female DC Euro Micro connector cable for quick disconnect photoelectri C 4 pin 4 wire PVC 16 4 feet 5 meter length sensors CSAS4F4CY2202 AC femal icro connector cable for quick disconnect photoelectric BS AC 4 pin 4 wire PVC 6 feet 2 meter length 1 2 20 Ors Straight threa CSAS4F4CY2205 AC fema icro connector cable for quick disconnect photoelectric sens ors straight e AC 4 pin 4 wire PVC 16 4 feet 5 meter length 1 2 20 UNF thread CSASSASCY2202 AC fem icro connector cable for quick
15. 1111 Lower junction box ne Upper junction box 24V bin signal A source power L 22 00 DISPENSER i esl 83 Ww b Se P ur E UNE ew eB power Left junction box Right junction box i GRN source GND i BL_ MERE UNUIRICUSETTE i Icemaker 2 E optional e GND RD 4 Lower junction box 1 Electric Upper junction box GRN EE 24V bin signal power power source E E a 1 eov i eB _ 4 Installing Satellite fill icemaker rough in utilities with optional slide out accessory The slide out accessory allows the icemaker to be pulled out on a track from below a counter without disconnecting utilities A leg supports the icemaker in the full out position If your order did not include a slide out accessory proceed to icemaker ventilation and exhaust Step 1 Installing track accessory Follow either A or below for Satellite fill icemaker Track must be positioned flush against inside of counter and slightly above counter access opening A When icemaker stand is used required if icemaker is not supported on counter channels 1 Bolt vertical utility panel to slide out track assembly with supplied 10 32 screws 2 Secure slide out tr
16. All have a solid state output rated 0 7 amps 240 VAC They switch one circuit SPST Reset time is 300 mS Power consumption is 5 mA and mechanical life is 100 million cycles Size is 3 Ht x0 7 Wd 2 4 Dp UL recognized CSA certified and CE approved When in switch on initiated interval single shot and switch off initiated interval delay on break operating modes relays have an tiation time of 32 mS Knob adjustable relays are easy to adjust Timing range is 0 1 sec ond to 100 minutes DIP switch adjustable relays are more precise than knobs with six switches to adjust the time delay Plus it s easier to set multiple relays to the same timing range Timing range is 0 1 second to 63 minutes Please specify control voltage 24 240 VAC or 9 110 VDC McMASTER CARR Socket for Miniature Plug In Relay 8 89 Socket for Plug In Panel Mount Relay 4 6 89 Panel Mount Bracket for Plug In Panel M ount Relays 6963K22 8 82 35 mm DIN Rail 1 m Lg 4 76 DIP Switch Knob Adjustable Adjustable Relay Relay with Quick with Terminal Disconnect Block Adjustment Type Terminal Connection Each Knob V4 Quick Disconnect Knob Terminal Block DIP Switc 35 mm DIN Rail 1 m Lg 8961 15 LUX Series Recessed Fixture 3x1W 10 Stainless Steel ILTILEDS 3 x 1W 350 high emission LED LUX Series 3x1w 350mA high emission LED fixed focus fixture w
17. B E DR C and WTR LEDs are all on INPUT POWER WATER GRD SENSOR pwr G RESET B GRD L1 W WHITE ory CONTROL 20 x Le BOARD CK M BLACK WHITE L2 12 wrR 5 COMPRESSOR Qer BLACK FAN Ose DRIVE 2 1 BLACK 2 BLACK E Y 5 lt RED HIGH PRESSURE Q z SAFETY SWITCH COMPRESSOR GEARMOTOR WHITE 1 I 4 BLACK A WHITE WHITE START BIN SIGNAL YELLOW RUN FROM DISPENSER BIN T STAT OAT JUNCTION BOX TOL MCD400A WVS series uc cR E blk wire is on 24V Normal operation Stage 4 Once the ice level control opens the B E LED goes out After a 10 second delay the LED C compressor and fan motor go off and the B T LED comes on Should the ice level control not remain open for 10 seconds the icemaker will continue to run The gearmotor continues to run for 60 seconds The purpose of this function is to drive the remaining ice out of the evaporator and to boil off any refrigerant remaining in the evaporator INPUT POWER WATER G SENSOR e PW
18. Solution A Ice machine cleaner Prepare one gallon 3 8L of Follett SafeCLEAN Ice Machine Cleaner one 7 oz packet or equivalent Solution temperature must be at least 120 F 49 C Warning Most ice machine cleaners contain citric or phosphoric acid that can cause skin irritation Read caution label on product and follow instructions carefully Solution Sanitizing solution Prepare 2 gallons 9L Combine 1 2 30ml bleach with 2 gal 8L hot water at least 120 F 49 C or use 200ppm of Ecolab Mikro chlor Cleaner or equivalent 5 25 sodium hypochlorite solution 1 Remove icemaker panels required to gain access to water reservoir components Fig 5 and electrical control box 2 Turn compressor switch on electrical box to OFF position K 3 Dispense all ice from dispenser KA 4 Shut off water to icemaker 93 5 Drain water from reservoir through float evaporator drain line Fig 5 1 Reinsert hose into hose clip Fig 5 3 5 M 6 Fill reservoir and evaporator Fig 5 2 with Solution A e 7 compressor switch is the off position Restart icemaker and allow gearmotor to run for 15 minutes 8 While waiting 15 minutes follow steps 8a through 8c a Remove ice compression nozzle Fig 6 1 Soak in Solution A Note No compression nozzle on 400 series flake icemaker b Descale drain pans Fig 6 2 by grasping firmly and gently bending up and down Vacuum residue out Inspect a
19. from evaporator port Evaporator reassembly Fig 7 NOOR ONS 9 10 11 12 13 14 Clean gearmotor boss output shaft and shaft well Install drain pan and evaporator mounting base Fill gearmotor shaft well with food grade grease Fig 8 Install condensate shield and seat against gearmotor boss Install mounting base O ring in groove in evaporator mounting base Lower bottom bearing assembly into evaporator mounting base While maintaining a downward pressure on bottom bearing assembly tighten hex head bolt with a 5 16 wrench Position evaporator over lower bearing assembly and align grooves with pins in bearing assembly Install vee band clamp and nut and tighten to 70 in Ib Place auger in center of evaporator and rotate to mate with drive pin Install ice compression loop orienting loop as shown in Fig 7 Note No compression nozzle on MFD400 series flake icemakers Install upper bearing and seal assembly rotating bearing to slip pin into auger slot Install upper vee band clamp and nut and tighten to 70 in Ib If evaporator was replaced reinstall compression nozzle Gearmotor replacement Fig 8 1 2 3 Disassemble evaporator as described above Disconnect the wire connectors Remove 4 screws holding gearmotor mounting plate to base of icemaker and lift gearbox and motor clear of icemaker Fig 8 1 Remove machine screws holding mounting plate to motor Fig 8 2 Install new motor
20. run of tube potential dispensing problems No dips or tight bends Tube secured in place No splices LLL 15 Additional ice transport tube connection specifications for Vision series ice and beverage dispensers Check to make sure bin signal on icemaker control board is switched to 24 volt connection 1 Push one end of ice transport tube s through hole s provided in side of dispenser 2 Route tube into ice tube bracket inside dispenser and engage bracket tabs in holes located in end of ice transport tube s see drawings below 3 Verify bin thermostat capillary tube is mounted correctly see drawings below Ice tube retainer bracket 1 26mm ice tube retaining bracket 28 Bin thermostat capillary tube mounting Front View VU155 Front View VU300 ice tube retaining a bracket thermostat thermostat pem tabs in ice tube ice tube ice tub
21. separate circuit with electrical disconnect within 10 ft 6m Equipment ground required Standard electrical 115V 60Hz 1 phase Maximum dispenser fuse 15 amps Maximum icemaker fuse 20 amps each Maximum icemaker amperage 11 amps each Cord and plug provided on icemaker and dispenser Electrical connections Model Electrical connection Circuits required 25FB400A W 50FB400A W 110FB400A W cord amp plug provided 115 60 1 20 amp max fuse size 25CT400A W 50CT400A W 110CT400A W cord amp plug provided 115 60 1 20 amp max fuse size 25CR400A W 50CR400A W 110CR400A W dispenser icemaker 115 60 1 2 circuits required and bin signal dispenser 15 amp max fuse size cord amp plug provided icemaker 20 amp max fuse size VU155R400A W VU300R400A W dispenser icemaker 115 60 1 2 circuits required VU155BR400A W VU300BR400A W and bin signal dispenser 15 amp max fuse size VU155R400A WX VU155BR400A WX cord amp plug provided icemaker 20 amp max fuse size VU155NR400A W UD300R400A W dispenser icemaker 115 60 1 3 circuits required VU155R800A W VU300R800A W and bin signal VU155R800A WX cord amp plug provided dispenser 15 amp max fuse size VU155BR800A W VU300BR800A W 2 icemakers 20 amps max fuse VU155R800A WX size each A CAUTION Check start relay before supplying power Start relay is gravity sensitive and MUST be in position Failure to comply may caus
22. the market both 50 0H forward phase control leading Frequency edge dimming and reverse Power Factor gt 0 9 hase control trailing edge ond eee Efficiency 80 dimming e Constant DC current output over Turn off time range of 1000X Undimmed 5 6V min 42V max e MAX load 12 LEDs output voltage MIN load 3 LED e Output short circuit protection FCC Consumer Class e Active power factor control e Compact lightweight e Dimensions in Lx W x e Patent pending 7 09 x 1 73 x 1 18 UL recognized Class 2 e Output wires red amp black Insulated 18 AWG 300V 200C UL1332 SUELEN BU e Input wires black amp white e 25C to 50C El 2 E gt LED 18 350 120 D 5 ep o i 182 5 mm 71 2 190 7 5 198 7 8 LED 36 1050 120 D can only drive up to 8 LEDs es WWW LIGHTECHINC COM INTRODUCTION TO LIGHTECH PHASE CONTROL DIMMING LED DRIVERS These products make possible control of LED light output over a range in excess of 1000X The same light can function both as a night light and as a regular room light It can perform this function in conjunction with the most inexpensive TRIAC dimmers that can be found in the hardware store Putting three of these products together controlling red green and blue LEDs each with a separate dimmer allows an economical means of color mixing For more elaborate installations a thr
23. 12 305mm minimum clearance above icemaker for access to icemaker components 6 153mm minimum clearance between exhaust side of icemaker and adjacent equipment Do NOT weld icemaker to counter channels Large removable panels in counter face to allow icemaker removal Machine stand accessory required for icemakers not supported on counter channels Connection requirements Compression fittings for water and drain lines Separate drains for condenser and icemaker Do NOT connect drains 20 amp power supply with 6 feet bin signal from dispenser to icemaker 12 305 clearance separate power Y to icemaker separate power front of to dispenser icemaker Note Diagram intended as guide only All field wiring to be installed in accordance with NEC and local electrical codes water shut off ON compression fittings oS for water and drain lines 11 9 Field wiring diagrams for Satellite fill icemaker installations All field wiring must be installed in accordance with NEC and local electrical codes Field wiring diagram is intended only to aid electrician or technician in understanding how equipment works Should local codes require a hard wired connection and or shielded wiring eliminate
24. 2 502110 Loop ice compression beveled all icemakers except MFD400 series see flaker specific components below 3 502737 Auger all icemakers except MFD400A W see flaker specific components below 4 502725 Evaporator includes insulation jacket 502740 5 500496 O ring bearing housing 6 502738 Bearing assembly bottom includes O rings and condensate shield 7 501063 O ring mounting base 8 500744 Shield condensate 9 501080 Screw Allen 1 4 20 x 1 2 set of 4 10 502733 Mounting base evap includes 501063 11 502227 Bolt mounting base 12 502730 Gearbox amp motor assembly 13 502729 Mounting base gearbox Not shown 502220 Compression nozzle with double drain no nozzle in MFD400 series 14 502221 Compression nozzle with single drain no nozzle in MFD400 series 15 502727 Drain pan evaporator 16 502226 Clamp compression nozzle and screw 17 500680 Tubing compression nozzle drain s sold by foot 18 501111 Grease Chevron 2 1402 Not shown 502739 Bracket drain hose 19 502740 Insulation jacket evaporator 20 502742 Relay start gearmotor 21 502744 Drip cover gearmotor 22 502743 Evaporator amp gearmotor assembly Not shown 502775 Oil gearmotor 1 pint Not shown Flaker specific components Part Description Reference 00124123 Auger with paddle 3 00124115 Loop compression notched 4 32 Order parts online www follettice com Evaporator Air cooled icemakers Order parts online www follettice com
25. 3 4 5 6 Not shown Not shown Not shown Not shown 7 8 9 Not shown 10 Not shown 16 17 Not shown Not shown Not shown Not shown Not shown Not shown Not shown Not shown Not shown Order parts online Water cooled icemakers before serial number C57245 www follettice com 19 36 Water cooled icemakers before serial number C57245 Order parts online www follettice com Part Description Reference 502724 Drier 1 500537 Valve water regulating includes 501810 2 501810 Iso washer for water regulating valve Not shown 502116 Water sensor Not shown 500504 Float valve amp reservoir 3 501986 Reservoir mounting bracket 4 502079 Tubing polypropylene reservoir supply sold by foot Not shown 502078 Fitting plastic float valve includes sleeve amp stem Not shown 502220 Compression nozzle with double drain Not shown 502221 Compression nozzle with single drain Not shown Evaporator see page 32 and 33 for complete breakdown 5 00141440 Drain kit evaporator 6 502954 Drain kit evaporator water cooled freestanding units 6 502726 Valve expansion thermal 7 502727 Drain pan evaporator 8 501966 Tubing evaporator drain 3 4 19mm ID x 1 26mm OD sold by foot Not shown 502730 Gearbox amp motor assembly 115V 60Hz 9 502729 Mounting bracket gearbox 10 501191 Tubing plastic food grade 1 2 13mm ID sold by foot 11 500672 Motor fan 115V 60Hz 12 501188 Bracket fan motor 13 500790 Fan blad
26. 400A W wiring diagram 6 cece cece III 21 Electrical control system operation 6 cece cece cece mmm 22 Refrigeration Syslem age be 28 S rvice procedures dd voi s eed rade bes dp d RES cae fae 29 Evaporator disassembly 29 Evaporator reassembly 42 5 esses dee dae a 29 replacement 29 Troubleshooting 30 Replacement parts 555353 32 Welcome to Follett Follett equipment enjoys a well deserved reputation for excellent performance long term reliability and outstanding after the sale support To ensure that this equipment delivers that same degree of service we ask that you review the installation portion of this manual before beginning to install the unit Our instructions are designed to help you achieve a trouble free installation Should you have any questions or require technical help at any time please call our technical service group at 800 523 9361 or 610 252 7301 Before you begin After uncrating and removing all packing material inspect the equipment for concealed shipping damage If damage is found notify the shipper immediately and contact Follett Corporation so that we can help in the filing of a claim if necessary
27. 875 658mm Side view All customer field connections are made to rear of vertical 3 8 OD push in condenser inlet utility panel water cooled only cord holder 3 8 OD push in condenser drain water cooled only vertical utility panel 3 8 OD push in icemaker water inlet icemaker power cord gt 16 75 415mm bin signal cord connector 2 to connect to dispenser bin signal cord gt 3 4 MPT icemaker drain If UD 22 75 4 578mm Plan view 22 75 578mm Icemaker front 1 563 16 21563 40mm lt 407 gt 40mm 19 25 lt 489 25 875 4 658mm 13 Satellite fill icemaker ventilation and exhaust requirements Fabricator supplied custom air intake grilles must have 12 x 12 305mm x 305mm opening yielding 100 sq inches 645 sq cm of open air space within duct perimeter Block off any open area outside of the air duct Intake air requirements air cooled icemakers MCD400AHS MCD400AVS amp R400A only 1 Check that 2 51mm duct is installed on condenser front 2 Cuta 12 x 12 305mm x 305mm opening in counter face to align with duct 3 Position icemaker to mat
28. 95K81 58 95 VAC They plug into a socket and fit into a square On Delay 100 120 25 mA 1 sec 10 sec 9695 82 58 95 panel cutout when used with the optional mounting On Delay 100 120 25 6 sec 60 sec 69695K83 58 95 On Delay 100 120 25 mA 1 min 10 min 69695K84 58 95 brackets socket and brackets sold Separately at right Mechanical life is 10 million cycles unless noted CE approved Compact relays fit into a 1 30 1 30 cutout and are 1 4 Ht x 1 4 Wd 3 2 Dp and are 1 9 Ht x 1 9 Wd x3 7 Dp unless noted Multifunction relay has on delay delay on make repeat cycle interval and switch on initiated inter val single shot functions Large display relays Multifunction 12 have on delay delay on make and interval func Multifunction tions as well as everything you need to mount in a Multifunction 3 2 dia panel cutout All have a movable pointer Multifunction that shows status at a glance They switch one cir Accessories cuit on or off SPDT and are rated 10 amps 120 VAC Mechanical life is 5 million cycles Socket is DIN rail or surface mountable has two 0 165 dia mounting holes hardware not included See page 896 for more socket information Relays with Multiple Timing Functions Handy relays switch between on delay delay on make interval repeat Cycle switch off initiated interval delay on break and switch on initiated int
29. Check your paperwork to determine which model you have Follett model numbers are designed to provide information about the type and capacity of Follett equipment Following is an explanation of the different model numbers in the 400 series MCD400ABT Configuration S Satellite fill Application T top mount V Vision Condenser type B Bin air cooled H Harmony water cooled Icemaker capacity and refrigerant 400 400 Ibs 181kg day RA04A Voltage D 115V 60Hz Icemaker series Nugget icemaker MCD Satellite fill installation Vision ice and beverage dispensers and top installation Follett ice storage bins R Remote installation Symphony ice and water dispensers D Replacement icemaker Symphony ice and water dispensers Flake icemaker MFD Top installation Follett ice storage bins N Important cautions Moving parts Do not operate with front cover removed Hot parts Do not operate with cover removed To reduce risk of shock disconnect power before servicing Most ice machine cleaners contain citric or phosphoric acid which can cause skin irritation Read caution label on product and follow instructions carefully Ice is slippery Maintain counters and floors around dispenser in a clean and ice free condition Ice is food Follow recommended cleaning instructions to maintain cleanliness of delivered ice Specifications Electrical Each icemaker and dispenser require a
30. R RESET b GRD amp 11 W WHITE O 12 ES CONTROL L2 BOARD M BLACK WHITE L2 Q 2ND 12 RED 59 e ze Ost 1 i BLACK BLACK oo 5 5 N M 2200 22 i 1 ORANGE i 5 1 BLACK H i i RED BLACK E BLACK p HIGH PRESSURE 5 gt RED A SAFETY SWITCH 9 m COMPRESSOR poU GEARMOTOR 3 WHITE BLACK e cmm WHITE WHITE RED p BIN SIGNAL YELLOW Normal operation Stage 5 FROM DISPENSER JUNCTION BOX BIN TSTAT MCD400A WVS series wire is on 24V The B T LED will remain on for 20 minutes The icemaker will not start while the B T LED is on To restart the icemaker for troubleshooting purposes depress the reset button to clear the control board INPUT POWER WATER G SENSOR RESET B gt GRD L1 Q DR 77 WHITE D FAN CONTROL 20 2 BOARD BLACK BLACK WATE p er 12 cg wR zz Ost BLACK BLACK SCORES Ose M 1 L DRIVE 022 ORANGE 5 T BLACK H M BLACK E HIGH PRESSURE Q BI SAFETY SWITCH 9d COMPRESSOR GEARMOTOR 1 D WAITE 1
31. ack assembly to icemaker stand with 10 32 screws provided 3 Position icemaker stand in desired location and adjust stand legs to proper height and level in both directions 4 Using holes in flanged legs as template mark floor for 12 anchoring holes to be drilled 5 Remove stand track assembly and drill marked holes 6 Reposition and anchor stand to floor with 12 fasteners appropriate to floor material not supplied Stand MUST be anchored to avoid tipping and possible injury when icemaker is pulled out B When icemaker is supported on counter channels 1 Bolt vertical utility panel to slide out track assembly with supplied 10 32 screws 2 Position track assembly on counter channels Fig 3 3 Using holes in track assembly as a template mark and drill required holes in counter channels 4 Remove track assembly on channels and drill marked holes 5 Reposition track assembly on channels and secure using appropriate hardware not supplied 144 gt 356mm verical utility panel 356mm slide out track 11 Step 2 Installing Satellite fill icemaker on slide out track gt When icemaker is shipped with slide out track accessory follow either A or B Connect inlet water drain and power supply to back of vertical utility panel Place icemaker on slide out track assembly Connect drain and water lines Connect electrical plugs from icemaker to utility panel When icemaker i
32. an that the icemaker has experienced an over torque condition If the icemaker runs without problems for 60 minutes and no additional torque errors occur the 60M LED will go off and the icemaker will continue normal operation JUNCTION BOX MCD400A WVS series INPUT POWER WATER G SENSOR Q PWR RESET B GRD L1 e DR W WHITE 21 kn EAN L2 CONTROL 12 BOARD Q BLACK WHITE 12 eno 12 Hg x 1 2 B COMPRESSOR Ost i BLACK FAN so i 1 2 lt i ORANGE DRIVE L BLACK 2 4 4 i i BLACK BLACK S 1 m ag RED Ma olan LEE HIGH PRESSURE 5 SAFETY SWITCH COMPRESSOR ee GEARMOTOR WHITE 1 c 1 T WHITE WHITE RED T BIN SIGNAL Es YELLOW FROM DISPENSER T STAT blk wire is on 24V Diagnostic sequence Stage 9 The second error 2ND LED will come on if an over torque condition occurs while the 60M LED is still lighted The 2ND LED will indicate to the technician that two consecutive over torque situations have occurred The icemaker will shut down at this time and lock out It will not restart unless the manual reset button is depressed
33. ater cooled freestanding units 6 502726 Valve expansion thermal 7 502727 Drain pan evaporator 8 501966 Tubing evaporator drain 3 4 19mm ID x 1 26mm OD sold by foot Not shown 502730 Gearbox amp motor assembly 115V 60Hz 9 502729 Mounting bracket gearbox 10 501191 Tubing plastic food grade 1 2 13mm ID sold by foot 11 502782 Overload compressor 115V 60Hz Not shown 502731 Compressor 115V 60Hz 12 00117234 Coil condenser 13 502741 Base L400W 14 500376 Strainer water threaded connections Not shown 502920 Strainer push in connections Not shown 502734 Waiter inlet and drain assembly brass Not shown 502924 Water inlet fitting plastic Not shown 502925 Water inlet elbow plastic Not shown 00109728 Drain fitting plastic Not shown 502348 Assembly drain single fitting Not shown 502732 High pressure cutout 15 502830 Jacket insulation TXV Not shown 204584 Ty rap 2 required 16 00143941 Fitting condenser drain 17 502698 Bracket ice tube entry Not shown 39 Electrical components Order parts online Part 502780 501588 502331 502116 502392 500514 501959 www follettice com 2 3 4 WATER Y PROBE O DR 2ND O WTR O BT OB E _ of 5 Description Reference Capacitor start compressor 115V 60Hz 1 Relay start compressor 115V 60Hz 2 Board control circuit 115V 60Hz 3 Water sensor Not shown Switch on
34. cles 1 Compressor start relay in wrong position 1 Position relay with arrow or word top intermittently 2 High pressure cutout open due to high facing up head pressure 2a Check supply and temperature of System status 3 Clogged or dirty condenser coil water to w c condenser gearmotor and fan 4 Improper ventilation 2b Check discharge pressure and adjust motor run 5 Defective compressor water regulator value 3 Clean condenser coil 4 Provide inlet and exhaust air provisions per Follett icemaker installation manual 5 Replace compressor 9 Unit runs but 1 Clogged or dirty condenser coil 1 Clean condenser coil making ice 2 Compressor not pumping 2 Replace compressor 3 Low refrigerant charge 3 Check for leaks repair evacuate and System status weigh in correct charge compressor gearmotor and fan motor running 10 Compressor and 1 Compressor switch in OFF position 1 Turn compressor switch on fan motor will not 2 No output on compressor and fan motor 2 Replace control board run Gearmotor terminals on control board 3 Replace fan motor 1 Intermittent noises from evaporator Mineral build up evaporator surface k Clean evaporator with liquid IM cleaner 31 Replacement parts Order parts online www follettice com Evaporator Part Description Reference 502735 Coupling vee band includes nut 1 502736 Bearing assembly top
35. com Installation Operation and Service Manual 9 2 amp Following installation please forward this manual to the appropriate operations person y 7 m 801 Church Lane Easton 18040 USA OLE 77 Toll free 800 523 9361 610 252 7301 Innovative solutions inspired by ice Fax 610 250 0696 www follettice com 8 208600R16 Follett Corporation Equipment Return Policy Follett equipment may be returned for credit under the following conditions 1 The equipment is new and unused 2 A return authorization number has been issued by customer service within 30 days after shipment 3 Follett receives the equipment at the factory in Easton PA within 30 days after issuance of the return authorization number 4 equipment must be returned in Follett packaging If the packaging has been damaged or discarded Follett will forward at the customer s expense new packaging Note Return freight charges are the responsibility of the customer If equipment is returned and is damaged because of improper packaging Follett Corporation will not be held responsible Credit will be issued when The equipment has been inspected by Follett and deemed suitable to be returned to stock Note 15 restocking charge will be deducted from the credit If the cost to return the product to stock exceeds 15 the actual cost will be deducted Table of contents Welcome to Follett C
36. compression loop where it is compressed to remove excess water When the ice reaches the desired hardness it rotates within the cavity and is forced through a discharge port and compression nozzle and into the ice transport tube The discharge tube and compression nozzle are slightly restricted to further compress the ice and produce the desired hardness Note MFD series flake icemakers have no compression nozzle As the formation of ice continues ice in the transport tube is pushed through the tube to the storage compartment in the ice dispenser or ice storage bin A solid state control board located in the electrical box of the icemaker controls the normal operation of the icemaker and monitors gearmotor torque This control board will shut down the icemaker should an over torque condition occur It is very important that you familiarize yourself with the operational sequences detailed in this manual before attempting to service the icemaker Harvest system diagram evaporator 7 ice transport tube compression nozzle water 19 Technical specifications all models Refrigeration system diagram condenser __ filter dryer high side service port LH thermostatic expansion valve Refrigeration pressure data Notes 1 lt lt evaporator high pressure switch low side compressor high high pressure pressure
37. disconnect photoelectric 35 5 pin 5 wire 6 feet 2 meter length 1 2 20 015 straight threa CSMS4A4CY1602 Mi fem i connector cable for oe 4 pin 4 wire PVC 6 feet 2 meter length 7 8 16 UN th uick disconnect photoelectric sensors straight CSMS4A4CY1606 Mi fem i connector cable for u e 4 pin 4 wire PV disconnect photoelectric sensors straight 69 feet 6 meter length 7 8 16 UN thread CSMSSASCY1602 Mi fema i connector cable for LS 52 Pa 5 pin 5 wire PV th disconnect photoelectric sensors straight CSMSSASCY1606 Mini connector cable for femal k feet 2 meter length 7 8 16 UN k u 20 C3 5 pin 5 wire PV Note Cutler Hammer parts available for sale to North America locations only disconnect photoelectric sensors straight 9 69 feet 6 meter length 7 8 16 UN thread Connector Cables Specifications Micro Style 5 White Mini Style Jacket Material PVC PVC Contact Material Gold plated copper alloy Gold plated brass Coupling Nut Material Zinc die cast epoxy coat Zinc die cast epoxy coat O ring Nitrile rubber None Cable PVC insulation and jacket stranded copper conductors Cable Strain Relief 35 pounds minimum
38. e Inlet Water Temperature F C Note Nominal values actual production may vary by 10 Gearmotor data Gearmotor current 2 25A nominal Locked rotor amps 14 amps Electrical control system operation MCD400A WBT MCD400A WHT and MFD400A WBT wiring diagram Follett icemakers used on top of an ice storage bin have a slightly different circuitry A diagram for these icemakers is shown below The operational and diagnostic stages for these icemakers will be otherwise the same as the following stages 1 10 INPUT POWER WATER w B G SENSOR GRD Opwr RESET BED BIN T STAT v s cad WHITE Qc z 12 3 m CONTROL mE e FAN M BOARD BIN SIGNAL BLACK WHITE L2 FROM DISPENSER 2 JUNCTION BOX COMPRESSOR RED 20 COMPRESSOR 7 er BLACK BLACK FAN BSR OBE RED L DRIVE 2 T RED ORANGE j 21 TOL S LJ BLACK BLACK T HIGH PRESSURE 2 COMPRESSOR BLACK SAFETY SWITCH SWITCH WHITE g c m 4 2 BLACK NA BLACK WHITEL WHITE le START GN RUN 5 T O L GEARMOTOR 21 Electrical control system operation The D400A W MCD400A WVS and R400A W
39. e ice tube retainer bracket retaining engage holes in ice bracket thermostat tube and hold tube in place 16 Ice transport tube installation detail install insulation on full run of tube Evaporator grommet install clamp behind lip on evaporator port Satellite fill icemaker start up procedure The start up procedure below is intended to ensure that icemaker is operating properly after installation has been made Check each item listed and call factory immediately for assistance if you experience problems with unit Before turning on power 1 Turn on water to icemaker 2 Push down on float to force water through overflow chamber into evaporator drain pan and check for proper drainage of drain pan 3 Check that float valve shuts off incoming water when raised 4 Check that hose clamp securely holds ice transport tube on evaporator port After turning on power 1 Turn on power to icemaker and confirm that gearmotor fan motor and compressor start immediately 2 Check that ice begins to enter dispenser bin area within approximately 10 minutes 3 Check that float reservoir water level is approximately 3 8 95mm below overflow during icemaker operation and adjust to this level if necessary 4 Putice against bin level thermostat in dispenser bin and check that compressor and fan motor shut down approximately 10 seconds after thermostat opens Gearmotor should run for an additional 60 seco
40. e 14 502782 Overload compressor 115V 60Hz Not shown 502731 Compressor 115V 60Hz 15 00111898 Coil condenser 16 502741 Base L400W 17 500376 Strainer water threaded connections Not shown 502920 Strainer push in connections Not shown 502734 Water inlet and drain assembly brass Not shown 502924 Water inlet fitting plastic Not shown 502925 Water inlet elbow plastic Not shown 00109728 Drain fitting plastic Not shown 502348 Assembly drain single fitting Not shown 502732 High pressure cutout 18 502830 Jacket insulation TXV Not shown 00143941 Fitting condenser drain 19 502698 Bracket ice tube entry 20 37 Order parts online Water cooled icemakers after serial number C57244 www follettice com 17 38 Water cooled icemakers after serial number C57244 Order parts online www follettice com Part Description Reference 502724 Drier 1 500537 Valve water regulating includes 501810 2 501810 Iso washer for water regulating valve Not shown 502116 Water sensor Not shown 500504 Float valve amp reservoir 3 501986 Reservoir mounting bracket 4 502079 Tubing polypropylene reservoir supply sold by foot Not shown 502078 Fitting plastic float valve includes sleeve amp stem Not shown 502220 Compression nozzle with double drain Not shown 502221 Compression nozzle with single drain Not shown Evaporator see page 32 and 33 for complete breakdown 5 00141440 Drain kit evaporator 6 502954 Drain kit evaporator w
41. e duct flush with back of counter opening 4 Install supplied grille on outside of counter opening Exhaust air all icemakers MCD400A W 8 R400A W Provide 100 sq in 645 sq cm of counter opening for exhaust air at least 18 457mm from intake opening but not more than 10 ft 8m away MCD400AHS MCD400AVS amp R400A Side View Standard louvered grille supplied NE aes Air intake Exhaust air Supplied 2 51mm duct MUST be installed to front of icemaker and mated flush to inside of counter face opening Front View Standard 51mm 2 duct mates counter Exhaust air opening out side to behind grille to opening at least E condenser front 457mm 18 from air intake TN Nn Air 1 through louver Air out through louver Provide at least 645 sq cm 100 sq inches of counter opening for exhaust air 14 Satellite fill icemaker ice transport tube installation Incorrect ice transport tube installation can result in wet ice and dispensing problems Follow guidelines below to ensure correct installation Call factory for assistance if you are unable to meet these requirements General requirements Maximum length of tube run
42. e equipment to overheat resulting in equipment failure equipment damage or fire hazard s lt gt UP top mount Satellite fill position freestanding position Plumbing 3 8 OD push in water inlet 3 4 MPT drain 3 8 FPT condenser inlet water cooled condenser only 1 25 gom minimum available flow 3 8 FPT condenser drain water cooled condenser only Notes Slope to drain of 1 4 per foot 6mm per 30 4cm run with a 1 2 min is recommended Water shut off recommended within 10 feet 3m drain to be hard piped and insulated Separate drains for icemaker and condenser To prevent back flow do NOT connect drains Follett recommends installation of an activated carbon filter in icemaker inlet water line Ambient Air temperature 100 F 38 C max 50 F 10 C min best performance below 80 F 27 C Water temperature 90 F 32 C max 40 F 4 C min best performance below 70 F 21 Water pressure 70 5 max 482 10 P S I min 89 Dimensions clearances Entire front of icemaker must be clear of obstructions connections to allow removal 12 305mm clearance above icemaker for service 6 153mm minimum clearance between exhaust side of MCD400A amp R400A 18 457mm minimum 10 ft 3m intake grilles Front view air cooled top mount LL FH HHH MINI
43. ee channel dimmer with memory can provide a repertoire of preset colors and lighting levels Contact your Lightech sales representative for a list of recommended dimmers The dimming response is smooth and intuitive and the 1000X plus range of control gives the operator a sense of control never before possible Specifiers will appreciate the quality of these products which have e 120 Hz ripple less than 2 e Power Factor gt 0 99 e THD lt 20 e Certification to pass FCC consumer emi requirements e Turn off time less than 100 m secs e Maximum output current inside 4 of nominal independent of line voltage e High quality internal components operated at low temperatures which predict a lifetime in excess of ten years of continuous operation for the 18W product e Internally protected against power line surges UL class 2 isolation for complete handling safety e Internally protected to withstand indefinite open circuit and short circuit conditions with automatic reset e No audible acoustic noise e Capability to work with any dimmer sold in the US today either regular TRIAC dimming or reverse phase control trailing edge dimming WWW LIGHTECHINC COM TYPICAL MOUNTING INFORMATION Lightech phase control LED drivers TIN PLATED max 3m 118 x gt BLACK WIRE u From 3 to 12 leds in series 205 z Q S WHITE WIRE uz max 3m
44. ee lead male 502336 Plug twist lock three lead female 502794 Panel right hand louvered R400A MCD400A W 502795 Cover top RA00A W MCD400A W 502796 Panel front utility R400A MCD400A 502797 Panel top front RA00A MCD400A 502798 Panel left hand amp rear RA00A W MCD400A W 502799 Panel front RA400W MCD400W 502800 Filler base RA00A W MCD400A W 502801 Condenser L400W 502802 Power cord R400 MCD400 502803 Bin signal cord R400 MCD400 502874 Grille condenser T400A and MCD400AHT 502875 Filter air T400A and MCD400AHT 00918045 Assembly front cover 41 Replacement icemaker ordering matrix Order parts online www follettice com Dispenser models Replacement icemaker model Dispensers with top mounted icemakers 50CT400A amp 50HT400A D400A 50HT400W 50HT400W D400W 25CT 400A amp 25HT400A D400A 25CT400W amp 25HT400W D400W 110 400 D400A 110CT400W D400W Dispensers with remote icemakers 25CR400A amp 25HR400A R400A 25CR400W 25HR400W R400W 50CR400A amp 50HR400A R400A 50CR400W 50HR400W R400W 110CR400A R400A 110CR400W R400W All U150 VU155 series with air cooled icemakers MCD400A All U150 VU155 series with water cooled icemakers 400 All VU300 series with air cooled icemakers MCD400A All VU300 series with water cooled icemakers MCD400W Dispenser models Replacement icemaker model Freestanding dispensers with icemakers i
45. erval single shot functions They have two rotary switches one selects the timing range the other selects operating mode All are 11 pin circular pin style and plug into a socket sold separately at right They switch two circuits or off DPDT Rated 10 amps 9 240 VAC Reset time is 150 mS Mechanical life is 10 million cycles UL and C UL recognized Plug in relay has five timing ranges Please specify control voltage power consumption 24 VAC 83 mA 120 VAC 17 mA 240 VAC 8 mA 12 VDC 166 mA or 24 VDC 83 mA Plug in panel mount relay has six timing ranges Control voltage is 24 240 VAC Power consumption is 51 mA Fits a standard 1 77 1 77 16 DIN panel cutout when used with the panel mount bracket sold separately hardware included Socket sold separately is DIN rail or surface mountable has two 0 165 dia mounting holes hardware not included See page 896 for more socket information On Delay 100 120 Standard Relays 8 Pin Circular Pin Multifunction 100 240 Standard relays fit into a 1 77 x1 77 Yie DIN cutout Pon Cycle 100 240 100 mA Delay 100 120 Off Delay 100 120 Large Display paye 14 Screw Terminals Socket for Compact and Standard Relays Panel Mount Bracket for Compact Relays Panel Mount Bracket for Standard Relays 35 mm DIN Rail 1 m Lg W Mechanical life is 20 millio 25 mA 6 min 60 min 69695K85 58 95
46. for example a compressor burn out refrigerant leak presence of non condensibles or moisture the system must be repaired evacuated and recharged using virgin or reclaimed refrigerant that meets ARI standard 700 88 3 Follett Corporation does not approve of recovered refrigerants Improper refrigeration servicing procedures will void the factory warranty Evacuation Evacuate the system to a level of 500 microns When the 500 micron level is reached close valves and both manifold and shut down the vacuum pump Allow the system to sit for approximately 20 minutes During this period the system pressure should not rise If the system pressure rises and stabilizes there is moisture in the system and further evacuation is needed If the pressure continues to rise check the system for leaks Ambients Minimum Maximum Air temperature 50 10 100 F 378 C Water temperature 40 F 4 4 C 90 F 32 2 C 1Ambient air temperature is measured at the air cooled condenser coil inlet 2 Ambient water temperature is measured in the icemaker float reservoir Ice capacity test Icemaker production capacity can only be determined by weighing ice produced in a specific time period Replace all panels on icemaker Run icemaker for at least 15 minutes Weigh and record weight of container used to catch ice Catch ice for 15 or 20 minutes Weigh harvested ice and record total weight Subtract weight of container from total weight Convert fractions of po
47. han 10 seconds no reaction will occur Normal operation Stage 1 Power is supplied to L1 of the control board The ice level control in the dispenser is closed and calling for ice supplying signal voltage to the control board The control board will now go through the start up sequence Less than 30 seconds will elapse as the water sensor located in the float reservoir checks for water in the reservoir The Bin Empty LED B E will be on INPUT POWER N WATER SENSOR PWR G L1 DR WHITE Li Oc L2 i2 CONTROL 20 FAN M BOARD Qem BLACK BLACK EE L2 B X ou 12 Own COMPRESSOR 29 er i COMPRESSOR M BLACK BLACK s r BE EAN 582 RED 1 1 M d Y DRIVE 1 TOL 5 1 H ES 1 BLACK m BLACK HIGH PRESSURE SAFETY SWITCH ova Sey als 4 x WW i WHITE WHITE START A T BIN SIGNAL YELLOW RUN FROM DISPENSER JUNCTION BOX Bola M ICD400A WVS series iae mca pae c Pc rM p hm eae ire ae ce etl wire is on 24V 22 Normal operation Stage 2 The water sensor verifies water in the float The Water OK LED WTR comes on At the same time the gearmotor compre
48. he requirements detailed in this manual If you cannot meet these requirements or have questions call our technical service group immediately at 800 523 9361 or 610 252 7301 Top mount icemaker on bin installation procedure models MCD400A WBT and MFD400A WBT Install icemaker and rough in utilities 1 Install ice storage bin in its final location 2 Install one supplied grommet in large knockout in base of icemaker and second supplied grommet in ice hole provided in top of ice storage bin 3 Rough in plumbing and electrical per specs provided 4 Flush all water lines before final hook up 5 Position icemaker with utility connections facing rear of bin A If new storage bin and icemaker position icemaker with connections facing rear of bin B If using existing bin place supplied gasket 2 5 64mm from front of bin Fig 2 Position icemaker with utility connections facing rear of bin Make final plumbing and electrical connections Working from inside bin storage area push end of transport tube without fasteners up through grommets into icemaker leaving about 2 51mm hanging down in bin 8 Route free end of tube to evaporator port 9 Slip a hose clamp in free end of tube 10 Push free end of tube on evaporator port and tighten clamp making sure clamp is positioned on evaporator side of flange no flange on MFD400 series flake icemaker 11 Position ice tube under float bracket retaining tab 12 Careful
49. in reverse order 28 Fig 7 8 apply grease Troubleshooting chart Flashing water LED at any time indicates that water signal to board had been lost for more than one second Ten second delay There is a 10 second delay in reaction to loss of water WTR or bin B E signals If signals are not lost for more than 10 seconds no reaction will occur Problem Indicators possible cause Corrective action 1 Icemaker will 1 No power to unit 1 Check that unit is plugged in circuit not run 2 Open bin level control breakers are on 3 Water OK LED WTR not on 2 Adjust or replace ice level control System status 4 20M or 2ND LED is on indicating that first Check reservoir for water restore compressor or second torque error has occurred water to unit gearmotor and fan 5 Gearmotor locked up immediate torque 4 See Problem 6 motor inoperative error indicated by LEDs when board is 5 Repair or replace gear motor reset 6 Replace gearmotor start relay 6 Open coil on gearmotor start relay causing an immediate torque error 2 Compressor will 1 Condenser coil plugged causing open 1 Clean condenser coil and replace not run overload or high pressure cut out overload if necessary 2 Defective starting capacitor 2 Replace start capacitor System status 3 Defective starting relay 3 Replace relay gearmotor and fan 4 Open motor winding 4 Check winding res
50. istance and motor run 5 No power output from compressor output replace compressor if necessary terminal on control board 5 Check terminal connection and replace control board if necessary 3 Unit cycles 1 Float reservoir running dry sensing probe 1 Check water supply to float and float intermittently signalling for system to shut down operation PC board will have flashing WTR LED System status compressor gear motor and fan motor cycle 4 Low ice production 1 Dirty condenser coil 1 Clean condenser Poor quality ice 2 Restricted air flow to condenser coil 2 Remove obstruction 3 Mineral coated evaporator 3 Clean evaporator 4 High ambient water supply and or air 4 Precool water and or install air duct temperature per Follett installation manual 5 Improper exhaust air provisions 5 Provide proper exhaust air provisions 6 Faulty expansion valve per Follett installation manual 7 Low refrigerant charge 6 Replace expansion valve 8 Superheat incorrect 7 Check for leaks repair evacuate and 9 Inefficient compressor weigh in correct charge 8 Check that TEV sensing bulb is securely clamped in place and not damaged check that insulated bulb cover is in place Replace TEV if necessary 9 Replace compressor 5 Water leaks from bottom of evaporator 1 O ring seal broken 30 Troubleshooting Problem Indicators possible cause
51. it Spring Mount 3 fo Fixture Catalog No Color Application ru Wie aah Focus Mounting R ng Accessories Spring White Interior High Stainless 5 T Rough in 55009 K Exterior 3 Emission Steel 10 Fixed n 68 Kit Spring White Interior High Stainless o I Rough in BLUX 0103 F25 W NX Exterior Emission Steel 10 BLUX 0103 F25 1 NX Blue 118107 High Exterior Emission Steel it Kit BLUX 0103 F25 2 NX Green 1118197 Exterior Emission Steel Kit BLUX 0103 F25 3 NX Yellow 1118197 High Stainless ic Fed Rough in Exterior Emission Steel it Kit BLUX 0103 F25 4 NX Red 118107 High Exterior Emission Steel Kit tel 949 581 9398 fax 949 581 2947 info visual lighting com www visual lighting com 9 Rancho Circle Lake Forest CA 92630 G RE 0 LED 18 350 120 D LED 26 500 120 D LED 36 700 120 D LED 36 1050 120 D Dimmable Constant Current LED Drivers for 330mA 500mA 700mA and 1050mA LEDs Features Highlight Electrical e Dimmable dims 3 12 LEDS 18W 26W 36W 700mA 36W 1050mA full bright to 0 1 light input watts 19 27 37 38 output with appropriate dimmers Output amps 35 50 70 1 05 ym most common Input voltage 120Vac 10 dimmers in
52. ith plain flat glass lens and 57mm outer diameter for indoor outdoor and submersible use stainless steel body with solid aluminum heat sink triple lens optics with 10 beam angle features easy to replace LED module recessed mounting with stainless steel tension clips included IP68 rated to 1m depth LED driver sold separately multiple LED colors available ETL listed Optional recessed mounting rough in kit also available Cut out dimension shown for spring mounting only 10 6 05 Applications Exterior Pathway and Landscape Lighting Showers and Saunas LUX 20 10 Cut Sheet 9H033 e NZ 9 KW 48mm Throw Average Beam Distance Foot Candles Diameter 1 ft 1700 fc 0 2 2 ft 425 fc 0 3 4 ft 106 fc 0 7 8 ft 21 fc 1 4 Photometrics based 5500 white light LED Please see website for most current photometric data Driver Driver Input Max Fixtures IP sold separately Capacity Voltage per Driver Rating 901 004 350 U 350 100 240v 50 60hz 1 IP67 901 010 350 10 350mA 95 265v 50 60hz 2 IP67 All drivers UL Listed For driver information see page 121 Circuit diagram on page145 Accessories Rough in Kits page 128 INSTALLATION INSTALLATION METHOD 1 METHOD 2 Rough in K
53. ll drain lines Clean as necessary with Solution Fig 5 9 Disconnect icemaker power 10 Drain Solution A through float evaporator drain line Fig 5 3 Rinse evaporator by filling reservoir Fig 5 2 with potable water and draining evaporator through float evaporator drain line Fig 5 3 three times Reinsert hose into hose clip Fig 5 3 and insert plug into end of drain line Fig 5 1 11 Connect ice transport tubes Fig 6 3 directly to evaporator outlet ports without ice compression nozzle Fig 6 4 12 Fill reservoir and evaporator Fig 5 2 with Solution B jc S 13 Rinse ice compression nozzle in clear water and submerge in cup of Solution B while performing steps 14 through 16 14 Turn on bin signal switch in electrical box to allow gearmotor to run 15 Wait 10 minutes Turn compressor switch on 16 Keep reservoir Fig 5 2 full of Solution B while making ice for 20 minutes 17 Turn compressor switch off 18 Rinse ice compression nozzles Fig 6 1 with water and reinstall Note No compression nozzles on MFD400 series flake icemaker 19 Drain any remaining sanitizing solution from reservoir through float evaporator drain line Fig 5 1 20 Fill reservoir Fig 5 2 with 120 F 49 C water Empty water through float evaporator drain line Fig 5 3 Repeat 3 times 21 Turn on water to icemaker 22 Turn compressor switch on 23 Replace reservoir cover and any panels removed to clea
54. ly slip ice level control stat alongside transport tube through both grommets and down into bin 13 Run ice level control stat down through one side of cap tube fasteners attached to ice transport tube form a 180 bend at end of tube and run back up through fastener Fig 1 14 Adjust loop length to provide desired ice level Loop must below end of ice transport tube 15 Carefully bend end of cap tube to prevent it from slipping out of clamp Fig 1 Fig 2 Replacing existing icemakers 5 lt bin top bin top top view shown ice transport tube add gasket ice level control stat fastener Apply supplied gasket to bin top 2 5 as shown Position icemaker on 64mm bin top ice level control stat gt existing gasket front of icemaker Before turning power on 1 Clean and sanitize ice storage bin in accordance with cleaning procedure in ice storage bin installation information packed with ice storage bin Turn water to icemaker on Remove cover on float reservoir Push down on float to force water out overflow tube and into evaporator drain pan Check that water drains freely from evaporator drain pan Lift float and check that float valve shuts off incoming water when raised After turning power 1 Turn power to icemaker on and confirm that gearmotor compressor and fan motor start immediately 2 Check that ice begins to enter bin within appro
55. n icemaker 24 Make ice for 30 minutes Dispense and discard all ice 25 Clean and sanitize dispenser as outlined in dispenser operation and service manual 18 Service Icemaker Operation all models Follett s icemaker consists of four distinct functional systems Refrigeration system Water system Harvesting system Electrical control system These four systems work together to accomplish the production and harvesting of ice A problem in any one of these systems will result in improper operation of the entire ice production cycle When troubleshooting the icemaker it is important to analyze the entire system operation to determine which system is not functioning properly then pinpoint the component within that system that is malfunctioning Determine what corrective action must be taken before making any adjustments or replacing any components The icemaking process The Follett icemaker uses a stainless steel jacketed evaporator and operates on a continuous freezing cycle Water is supplied to the evaporator from the water reservoir where the water level is controlled by a float valve This valve also shuts off the water supply when the icemaker is not running When the icemaker is running a layer of ice forms on the interior surface of the evaporator This ice is continuously removed by a slowly rotating 12 RPM auger The auger carries the ice upward into the cavity formed by the top bearing housing and the
56. n the base 25FB400A D400A 25FB400W D400W 50FB400A D400A 50FB400W D400W 110FB400A D400A 110FB400W D400W Nugget icemaker on top of bin MCD400ABT MCD400ABT MCD400WBT MCD400WBT Flake icemaker on top of bin MFD400ABT MFD400ABT MFD400WBT MFD400WBT 42 43 Harmony SafeCLEAN Satellite fill Symphony and Vision are trademarks of Follett Corporation y 7 m 801 Church Lane Easton PA 18040 USA OLE AF Toll free 800 523 9361 610 252 7301 208600R16 Innovative solutions inspired by ice Fax 610 250 0696 www follettice com 0 03 09 E T N Enhanced 50 Series Diffuse Photoelectric Sensors Cutler Hammer 9 models available Fiberglass reinforced plastic housing Field of view 2 8 Cable wires or mini micro connector termination NPN PNP Solid State Relay or SPDT EM Relay outputs IP67 rated 1351 6547 1351 6517 1351 6534 Note Cutler Hammer parts available for sale to North Amrica locations only Enhanced 50 Series Diffuse Photoelectric Sensors Selection Chart Voltage Sensing Optimum Sensing Part Number Price Range Range Range Beam Output Type Connection Type Cable Part Number 1351E 6517 lt gt 6 foot cable 300V Pre wired 6 ft 1 8 m 1351 6547 lt gt 19 49 Vpc Np 4 pin Euro Micro DC connector CSDS4A4CY2202 TSDS4A4TY 2205 1351E 6507 4 pin Mini connector CSMS4A4CY1602 TSMS4A4TY 1606 1351
57. ndicating that the control board has sensed an over torque condition above 3 AMPS on the gearmotor and shut the icemaker down The 20M LED will remain on for 20 minutes after an over torque condition has occurred The icemaker will remain off as long as the 20M LED is on When the 20M LED goes off the control board will try to go through a normal start up sequence The WTR LED remains on as long as the water sensor in the float reservoir senses water INPUT POWER WATER GRD SENSOR 1 RESET B GRD L1 Q DR w WHITE CONTROL m c 12 BOARD OR WHITE L2 12 2 j COMPRESSOR 5 Qer i 1 SOR B E 022 i ORANGE DRIVE lt i H 1 RED BLACK 2 BLACK w I 1 E RED DER SS HIGH PRESSURE Q SAFETY SWITCH COMPRESSOR 1 WHITE i g BLACK m WHITE WHITE START A 1 BIN SIGNAL i YELLOW RUN FROM DISPENSER 3 Mh wv 1 JUNCTION BOX BIN STAT f TOL MCD400A WVS series blk wire is 24 Diagnostic sequence Stage 8 If the restart is successful the 20M LED goes off the 60 minute timer LED 60M comes on The 60M LED will remain on for 60 minutes from restart A lighted 60M LED tells the technici
58. nds 5 Check that icemaker comes back on in approximately 20 minutes bin signal must be present Operation Cleaning and preventive maintenance all models Preventive maintenance Periodic cleaning of Follett s icemaker system is required to ensure peak performance and delivery of clean sanitary ice The recommended cleaning procedures that follow should be performed at least as frequently as recommended and more often if environmental conditions dictate Cleaning of the condenser can usually be performed by facility personnel Cleaning of the icemaker system in most cases should be performed by your facility s maintenance staff or a Follett authorized service agent Regardless of who performs the cleaning it is the operator s responsibility to see that this cleaning is performed according to the schedule below Service problems resulting from lack of preventive maintenance will not be covered under the Follett warranty Weekly exterior care The exterior may be cleaned with a stainless cleaner such as 3M Stainless Steel Cleaner amp Polish or equivalent 17 Monthly condenser cleaning air cooled icemaker only 1 Use a vacuum cleaner or stiff brush to carefully clean condenser coils of air cooled icemakers to ensure optimal performance 2 When reinstalling counter panels in front of remote icemakers be sure that ventilation louvers line up with condenser air duct Semi annual evaporator cleaning every 6 months Fig 5
59. off compressor 4 Bin thermostat MCD400A WBT MCD400A WHT MFD400A WBT and MFD400A WHT only Not shown Board stand off control 4 required 5 40 Order parts online www follettice com Water filter kits and cartridges 00130229 Follett QC4 FL4S water filter system includes FL4S primary cartridge and head coarse pre filter and head pressure gauge flushing valve assembled and installed on mounting bracket 00130245 Follett FLAS primary replacement cartridge 00130211 Everpure coarse pre filter cartridge Ice machine cleaner 00132001 SafeCLEAN environmentally friendly cleaner carton of 24 x 7 oz packets Miscellaneous 501860 Condensate pump 501781 Regulator water pressure 25 psi 502775 Oil gearmotor 1 pint 501111 Grease Chevron SRI 2 14 oz tube 500377 Clamp ice tube 501921 Grommet ice tube 502783 Duct 2 51mm 502781 Gasket air duct 501425 Grille 501986 Bracket float mounting 501759 Cord and plug female dispenser bin signal F1105A W 501858 Cord and plug female dispenser power all 25 50 110 series dispensers 501786 Cord and plug female dispenser bin signal all 25 and 50 series top mount and freestanding dispensers 501702 Control board adapter R404A to R12 502051 Cord and twist lock plug male icemaker bin signal 502052 Cord and twist lock plug male icemaker power 502333 Plug twist lock two lead male 502334 Plug twist lock two lead female 502235 Plug twist lock thr
60. orporation 0 cece cece 4 SPecifiCati 5 8 mount icemakers models T400A W MCD400A W MFD4OOA W 8 Satellite fill icemakers models MCD400A W R400A W 9 cee ed ney DUST ER E ER aie 14 l tansport EUER 15 ripa 17 Mem 17 Cleaning 17 Weekly exterior Care cag sudan YA sae HENCE 17 Monthly condenser cleaning 2 erre hh rhe bp ha rra 18 Semi annual evaporator cleaning e hen 18 ois bio LIII ILLI a E 19 operation Wigan vests TD a ve oW er RUN IR Ra T ayers 19 Technical specifications Sab 20 Refrigeration system diagram eee qu RR ere 20 Refrigeration pressure data 33333 20 Compressor Gala ses dd PO Ix NOR INO 20 Gearmmotor dala EUR IR OPI RI EN PORC donee PPS EO nes 21 MCD
61. s installed in and shipped with counter Remove two outer rear screws from icemaker and install supplied spacer and screw Fig 3 Place icemaker on slide out track assembly Connect drain and water lines Connect electrical plug from icemaker to utility panel Remove pin from adjustable leg Place hold down strap over leg block and secure strap to slide out assembly with supplied screws Fig 4 Reinstall pin in leg block At job site remove hold down strap and make utility connections at rear utility panel W position track accessory so that 2 51mm duct supplied with air cooled satellite fill icemaker mates with back of counter opening counter front grille supplied with air cooled satellite fill power cord bin signal cord icemaker connection N 1 0 customer connection air in air cooled units only Fig 3 lt Remove screw Install supplied screws and spacers hold down strap Fig 4 for installation remove and discard supplied screws for installation remove and discard 12 Front view 5 25 3 8 OD push in condenser inlet lt gt 134mm water cooled only 3 8 OD push in condenser drain icemaker water cooled only power outlet icemaker e 3 8 OD push in icemaker water inlet twist lock bin signal cord barbed push on icemaker UNO 1 lt 25
62. ssor and condenser fan motor come on lighting the Drive LED DR and compressor LED C The compressor is started through a current style relay that is pulled in by the initial high current draw of the compressor The gearmotor start windings are also energized through a current relay The B E and WTR LED remain on INPUT POWER WATER G SENSOR PWR RESET B c GRD L1 e DR W WHITE 11 CONTROL 60M BLACK BLACK WHITE L2 12 a Own COMPRESSOR z9 Ost COMPRESSOR 1 i FAN 892 RED DRIVE _ i E m f RED 1 HIGH PRESSURE 5 E E SAFETY SWITCH PE COMPRESSOR GEARMOTOR 1 WHITE WHITE BIN SIGNAL FROM DISPENSER JUNCTION BOX BIN Stal MCD400A WVS series SiGe SR blk wire is on 24V YELLOW Normal operation Stage 3 After the initial high current draw drops off the gearmotor start relay contacts open dropping out the start winding As the compressor comes up to normal running speed the compressor start relay contacts open dropping out the start winding of the compressor The icemaker is now in a normal icemaking mode The icemaker will produce ice until the bin level control in the ice dispenser is satisfied The
63. the cord and plug s and follow the appropriate field wiring diagram MCD400A W and R400A W icemakers have separate power supply from dispenser Electric disconnects required within 10 ft 3m for all hard wired connections Recommended junction box preparation hard wired Satellite fill icemakers 1 Cut plugs from supplied power cords 2 Replace upper power strain relief with 207 7 connector 3 Mount 2 x 4 junction boxes using Whe supplied holes icemaker face e 0 4 Make power signal connections w 25 50 or 110 ice and water dispenser with ONE Satellite fill icemakers dispenser models 25CR400A W 25HR400A W 50CR400A W 50HR400A W 110CR400A W Electric Electric power power source source Dispenser Lower icemaker Upper icemaker LEGEND junction box junction box EB junction box ee bin signal power RECTORS ND RN G EQUIPMENT GRN GROUND B 3 B BLACK Ww WHITE Ww GRN GREEN BL BLUE R B Y RD RED VU155 VU300 ice and beverage dispenser with either ONE or TWO Satellite fill icemakers Note 24V bin signal Verify black bin signal wire is on the 24V terminal Icemaker 1 optional 2 1112
64. trol or trailing edge dimmers should be explored since these generate much less interference
65. unds to decimal equivalents ex 6 Ibs 8oz 6 5 Ibs Calculate production using following formula 1440 min x wt of ice produced Production capacity 24 hr period Total test time in minutes 9 Calculated amount per 24 hours should be checked against rated capacity for same ambient and water temperatures in Ice Production Tables 28 Service procedures Evaporator disassembly Fig 7 1 2 3 4 10 11 12 13 14 15 Disconnect power to icemaker Shut off water to icemaker Drain evaporator and float tank Disconnect plastic tubing from evaporator water inlet drain pan stub compression nozzle tubing and reservoir overflow tubing from secured clip Disconnect ice transport tube from compression nozzle Note No compression nozzle on MFD400 series flake icemakers Loosen nut and remove upper vee band coupling from top of evaporator Lift top bearing assembly straight up with a slight rotating motion and remove Remove ice compression loop located at top of auger Lift auger straight up and out of evaporator Remove nut and lower vee band coupling from bottom of evaporator Lift evaporator to clear bottom bearing assembly Loosen hex head bolt in side of mounting base with 5 16 wrench and lift lower bearing assembly Remove condensate shield Remove 4 Allen head machine screws holding mounting base to gearbox If replacing evaporator remove compression nozzle
66. vapor liquid pressure liquid 202 ERI low pressure vapor Water regulating valve is factory set at 225 PSIG head pressure 2 Readings within 10 of above table values should be considered normal Air cooled Icemaker Refrigeration Pressure Discharge Pressure Suction Pressure Ambient air temperat ue F C FC 60 6 80 27 50 10 174 23 245 31 70 21 174 23 244 30 90 32 190 25 265 32 Icemaker inlet water temperat ue F C 100 38 237 37 326 38 347 40 Water cooled Refrigeration Pressure Icemaker inlet water temperature 70 21 50 10 Discharge Pressure Suction Pressure Condenser inlet water temperature 70 21 90 32 50 10 236 28 235 29 250 34 237 28 230 30 250 34 90 32 236 28 235 30 250 34 service port psi psi psi Compressor data Compressor current draw Air cooled Ambient air temp 60 F 15 6 C 70 F 21 1 C 80 F 26 7 C 90 F 32 2 C 100 F 378 6 3A 6 5A 6 7A 6 9A 71A Water cooled Water temp at float 50 F 10 C 60 F 15 6 C 70 F 21 1 C 80 F 26 7 C 90 F 32 2 C 6 6A 6 7A 6 7A 6 8A 6 9A Locked rotor amps 58 8 20 Air cooled icemaker capacity 24 hrs Water cooled icemaker capacity 24 hrs Performance with new RG Group 1 2 ton coil Note Data expressed in Ibs hr and kg hr Ambient Air Temperature F C Ambient Air Temperature F C Inlet Water Temperatur
67. wiring diagrams which follow illustrate the circuitry of Follett icemakers used with ice dispensers Both normal operation of the icemaker Stages 1 6 and non normal diagnostic sequences showing torque out Stages 7 10 for use in troubleshooting icemaker problems are shown Follett icemakers used on top of an ice storage bin have a slightly different circuitry The operational and diagnostic stages for these icemakers will be otherwise the same as Stages 1 10 that follow Circuitry notes When the icemaker is used with a dispenser it receives power from two sources the main power supply and the bin control signal power from the dispenser Disconnect both power sources before performing service When performing electrical service always use a meter to determine whether or not the components being serviced are energized High pressure cutout opens at 425 PSI and closes at 287 PSI auto reset Compressor switch should read open in on position Compressor start relay is position sensitive See label on start relay for proper orientation Bin signal may be 120V 60Hz 230V 50Hz or 24V 60Hz If bin signal is 24V 60Hz black bin signal wire must be moved from LINE VAC terminal to 24V terminal Flashing water LED at any time indicates that water signal to board had been lost for more than one second Ten second delay There is a 10 second delay in reaction to loss of water WTR or bin B E signals If signals are not lost for more t
68. ximately 10 minutes 3 With icemaker running check that float reservoir water level is approximately 3 8 10mm below internal overflow and adjust to this level raised line on side of reservoir if necessary 4 After making ice for 10 minutes put ice against ice level control stat cap tube and check that icemaker shuts down 5 Warm ice level control stat with your fingers and check that icemaker restarts in approximately 20 minutes Bin must be calling for ice Satellite fill icemaker installation procedure models MCD400A WHS and MCD400A WVS Satellite fill icemaker performance is very sensitive to the quality of installation To ensure proper performance ease of service and warranty coverage it is critical that you follow the requirements detailed in this manual If you can not meet these requirements or have questions call our technical service group immediately at 800 523 9361 or 610 252 7301 Installing Satellite fill icemaker and rough in utilities without optional slide out accessory The requirements below are for icemaker installation without the Follett slide out accessory These procedures ensure that the icemaker can be easily removed as one unit for cleaning and maintenance For installation with the slide out accessory refer to instructions to install icemaker and rough in utilities with optional slide out accessory General requirements Front of icemaker free of obstructions plumbing lines electric conduits

Download Pdf Manuals

image

Related Search

Related Contents

シグ”” 庫赤外線乾燥機 りこの取扱説明書をよくお読みの上、 機械の    Service Manual - Genie Industries      Magma EB2R User's Manual  MAP Mix Provectus - Lauper Instruments  Manual de servicio y montaje Válvula de cierre de seguridad válvula  取扱説明書 Naー3ー。  Plasma TV  

Copyright © All rights reserved.
Failed to retrieve file