Standard 22 NG002 E02
Contents
1. As you do so the heading value changes B38 changes the value downwards and B39 changes it upwards If you hold down the button the speed at which it changes will increase NOTE If the message AL no is displayed then the a m restriction of 5 hours is not over Move switch B37 DIP switch contact 1 back to the OFF position 4201 DOC010102 22 Edition February 2015 Operator Manual O Compass nee 22 ANSCH TZ Standard 22 Standard 22 Compact DIP switch B 37 DIP switch B 37 nn N EIER 12345678 B 12345678 OR DIP switch B 37 DIP switch B 37 OFF OPEN OFF OPEN Corrected Takenaka gt iu dd m o fter en adjustment 12345678 12345678 Figure 13 Procedure for setting compass zero Edition February 2015 23 4102 DOC010102 Operator Manual Compass Standard 22 and Standard 22 Compact 2 2 2 Speed error A speed error occurs while the ship is travelling This becomes greater as the speed increases and is more pronounced on northerly and southerly headings than on easterly and westerly headings Speed error is a physical deviation from the steering heading indicated on the gyro compass compass heading from the true heading chart heading It depends on the speed of the ship the heading it is steering and the latitude The speed error is typically within the range of 0 2 and with fast ships it can even reach 5 or more With automatic speed error correct
2. Raytheon Ansch tz GmbH Raytheon Ansch tz Postfach 1166 D 24100 Kiel Germany Tel 49 4 31 30 19 0 Fax 49 4 31 30 19 501 Email Service raykiel com www raytheon anschuetz de Standard 22 Compact GYRO COMPASS sont and Standard 22 GYRO COMPASS Type 110 233 NG002 E01 EQ Operator manual s gt 4201 DOC010102 Edition February 2015 Weitergabe sowie Vervielfaltigung dieser Unterlage Verwertung und Mitteilung ihres Inhaltes nicht gestattet soweit nicht ausdr cklich zugestanden Zuwiderhandlungen verpflichten zu Schadenersatz Toute communication ou reproduction de ce document toute exploitation ou communication de son contenu sont interdites sauf autorisation expresse Tout manquement cette r gle est illicite et expose son auteur au versement de dommages et int r ts Copying of this document and giving it to others and the use or communication of the contents thereof are forbidden without express authority Offenders are liable to the payment of damages Sin nuestra expresa autorizaci n queda terminantemente prohibida la reproducci n total o parcial de este documento as como su uso indebido y o su exhibici n o comunicaci n a terceros De los infractores se exigir el correspondiente resarcimiento de danos y perjuicios Operator manual O Compass Standard 22 Compass and ANSCH TZ Standard 22 Standard 22 Compact TABLE OF CONTENTS Page 1 General sare e Vx Na S usa ban ae E ne a OES
3. Quick Settling option reduces the settling in phase to one hour With it precision after one hour is better than 3 The Quick Settling function can be performed either with an Operator Unit type 130 606 or via a Distribution Unit with an Operator Unit type 130 626 The Quick Settling function can only be used if the ship s heading has not been changed between switching off and switching back on The Quick Settling function can not be used During the first setting up installation Ifthe ship s position was changed between switching off and on again of the compass If the temperature of the gyro supporting liquid is more than 30 C Edition February 2015 17 4102 D0C010102 Operator Manual Compass Standard 22 and Standard 22 Compact 2 1 1 Indications on the compass during the heating stage he 8g ae h heating current temperature approx 30 minutes until a temperature of 45 C has been reached I The temperature for the internal h LJ G g h I follow up system to switch on has e been reached Figure 10 Indications during the heating stage 4201 D0C010102 18 Edition February 2015 Operator Manual O S ompass Com dodici 22 ANSCH TZ Standard 22 Standard 22 Compact 2 1 2 Indications on the compass during the settling stage No NMEA Heading and NMEA RoT is displayed output during the settling stage 130 5 5 Continuous light Fo
4. bus or NMEA without SEC Outputs Distribution Unit NG002 003 1x RS232 for courseprinter 1x rate of turn analog 12 x Heading course bus or NMEA DV bus Status signals Functions Compass STD 22 Integral Speed Error Correction SEC Quick Settling via the operator unit 4201 DOC010102 Edition February 2015 Operator Manual O Compass ne 22 ANSCH TZ Standard 22 Standard 22 Compact 1 1 STD 22 Compact Gyro Compass The position and speed GPS and Pulse Log are supplied to the compass as input data Both types of data are required for the automatic Speed Error Correction function To activate this function the QS Operator Unit can be connected to the gyro compass as an option Repeater compass ordered separately 2x Heading corse bus or NMEA Operator Unit Quick Settling 130 606 option CED Status information GPS position E EE GPS speed cu G Available NMEA position UP Compass Quick Settling Option NMEA speed 1x course bus Pulse Log Direction Pulse Log Additional 18 36 V DC Output Box 146 103 or 24 V DC option 115 90V AG AC DC converter SSC NMEA Type 121 062 Step 6 steps degree Figure 1 STD 22 Compact Gyro Compass Speed Error Correction SEC This function automatically corrects the latitude error of the gyrosphere error in the gyro compass The gyro compass receives the data required to make the correction such as the speed and la
5. t ee 1 1 1 STD 22 Compact Gyro ComMpaSS ur 0 ve ern 3 1 1 1 STD 22 Compact Gyro Compass Scope of Supply Lsssuuuusssususes 5 1 1 2 STD 22 Compact Gyro Compass optional features susssluuus 6 1 1 2 1 Quick Settling operator unit 12s zeiten RE eR EX ee Pe CRISI E RUE 6 1 1 2 2 AC DC converter 121 062 ccc ccc n n nh nra 7 1 1 2 3 Additional Output Box 146 108 ssssssssssseseeee eh 7 1 2 STD 22 Gyro COMPASS yiee eu sera een rare De 8 1 2 1 STD 22 Gyro Compass Scope Of Supply 0 00 eee 11 1 2 2 Optional features for the STD 22 Gyro Compass 0 cece eee eee 12 1 2 2 1 AC DC converter 121 062 422244 Pita Pie Be ERR ER AREE Tia E 12 1 3 Technicaldatas 4d d ica ks a esit bes dal en dr ER HR So od tete s Mae ade 13 1 3 1 Mechanical dala vip as d ven DT ged asad Hi dne sib 13 1 3 2 Electrical dallas de e Such riot Sec CUP DEBER eis 13 1 3 3 General Technical Data 2 act Ree LENA EXE e LA ea 14 2 Controls and Indicators on the Gyro Compass issssessseessss 15 2 1 Switching on the STD 22 Compass 0 cece nennen een rennen nen 17 2 1 1 Indications on the compass during the heating stage nee een 18 2 1 2 Indications on the compass during the settling stage sesseesessus 19 2 1 3 Overview of indications digital display during operation lisse 20 2 2 Heading corFectloft as iussus TER rr sey aue eee Ee
6. to wait at least 15 minutes before accessing the interior of the gyro compass Otherwise the gyro system could be damaged 4201 D0C010102 46 Edition February 2015 Operator Manual O ompass Com direi 22 ANSCH TZ Standard 22 Standard 22 Compact Maintenance Supporting liquid distilled water and Pump Rotor have to be replaced every 18 24 months It is additionally recommended to clean the internal of the outer sphere and the gyro compass Instructions for carrying out this operation and a maintenance plan for authorized service personnel only are given in the service manual Edition February 2015 47 4102 D0C010102 Operator Manual Compass Standard 22 and Standard 22 Compact Intentionally left blank 4201 D0C010102 48 Edition February 2015
7. two ways to check the supporting liquid and to fill in supporting liquid distilled water The first section 3 1 4 1 has to be performed by switching off the gyro compass The second section 3 1 4 2 can be performed without switching off the gyro compass but it must be performed very carefully and ideally under calm sea conditions With switching off the gyro compass The measure below does not compensate the planned replacement of the supporting liquid In certain circumstances if the level of the supporting liquid falls suddenly you must establish the cause possibly a leak and correct the fault If the level of supporting liquid is too low the compass can be destroyed immediate measure Caution It is strongly recommended to perform a service within the next 6 months to check the compass Caution This measure is an exception to restore operation Edition February 2015 35 4102 D0C010102 Operator Manual Compass Standard 22 and Standard 22 Compact Caution Due to condition 4 we advice to arrange a service for a routine check during the next port stay to be on safe side Switch off the compass and wait approx 15 minutes otherwise the gyrosphere can be damaged Open the door of the compass housing paying attention to the earthing strip Place both hands under 2 of the 4 snap closures and release them by pressing with the thumbs Remove all connections cables that lead to the outer
8. x heading course bus NG002 003 or NMEA 1 x printer RS232 1 x rate of turn DV bus Operator Unit Type 130 626 Pulse Log Pulse Log Direction GPS Speed GPS Position Magnetic sensor 108 010 18 36 V DC or 24 V DC At a Distribution Unit with a DV bus application no speed option 115 230V AC ACDC converter and or position inputs should Type 121 062 be made Figure 5 STD 22 gyro compass Some other possible applications are shown in drawings appended at the Service Manual of this Compass STD 22 NG002 4201 D0C010102 8 Edition February 2015 Operator Manual O ompass Com aie ral 22 ANSCH TZ Standard 22 Standard 22 Compact The STD 22 gyro compass consists of the 110 233 NG002 gyro compass Operator Unit 130 626 Distribution Unit 138 118 NG002 003 Optional features AC DC converter 121 062 Gateway to an Autopilot The output interfaces on the STD 22 are as follows Heading corrected SEC as NMEA or course bus Data bus CAN Bus Status signals alerts error messages RS 232 for heading and rudder position printer connection Rate of turn DV bus The input interfaces on the STD 22 are as follows NMEA Position NMEA Speed Pulse Log Direction Pulse Log Status signals or pulses Optional features via a connected Distribution Unit Magnetic sonde Raytheon Anschuetz probe type108 010 FLUXGATE compass MINS Satellite Com
9. 02 II Edition February 2015 Operator manual O Compass Standard 22 Compass and ANSCH TZ Standard 22 Standard 22 Compact There is a reduced accuracy of the compass during the set tling stage The compass shows required accuracy after ending of the settling stage appr 4 hours after switching ON It is strongly recommended to observe to read all manuals within a Compass STD 22 application Edition February 2015 III 4201 DOC010102 Operator manual Compass Standard 22 and Standard 22 Compact Intentionally left blank 4201 DOC10102 IV Edition February 2015 Operator Manual O Compass Standard 22 u and ANSCHUTZ tandar Standard 22 Compact General This compass is designed for use as a navigation aid on board ships As a sensor and unaffected by the magnetic earth field it determines the north bearing and thus enables a heading to be steered in relation to true north This compass provides heading information and status signals to those responsible for heading setting In principle we can distinguish between two different applications for the compass The STD22 Compact Compass as a stand alone system and The STD 22 Compass used in conjunction with other system components An Operator Unit and a Distribution Unit are required to connect and to operate other system components The overview on the next page illustrates the functional differences between these two versions Edit
10. 2 The AC DC converter is supplied with 115 to 230 V AC on the input side and delivers 24 V DC as output voltage with a maximum output power of 240 W see separate manual no 4175 Figure 7 AC DC Converter 121 062 4201 D0C010102 12 Edition February 2015 Operator Manual O ompass Com aie ral 22 ANSCH TZ Standard 22 Standard 22 Compact 1 3 Technical data The technical data stated here apply equally to the STD 22 Compact Gyro Compass and the STD 22 Gyro Compass 1 3 1 Mechanical data Gyro compass see dimensional drawing 110 D 233 HP005 1 3 2 Electrical data Gyro compass Supply voltage 18 36 V DC Current consumption max 140W heating stage max 80W operation Edition February 2015 13 4102 D0C010102 Operator Manual Compass Standard 22 and Standard 22 Compact 1 3 3 General Technical Data Quick Settling function Reduces the settling in phase to approximately 1 hour Quick Settling should only be used when the heading of the vessel has not been changed during the period between switching off the compass and switching it back on and if the compass has been switched off for a duration of min 1 hour before Speed Error Correction Automatic correction of a heading related to speed and degree of latitude see also section 2 2 Pulse log input 200 Pulses Nm Pulse log Direction input Speed ahead Speed astern or reverse speed status GPS in
11. E ERE IHE E Rd 21 2 2 1 Alignment erro cures vuU ee REA UN UE DR ER E e Pee dct ts 21 2 2 1 1 Procedure for setting the compass zero A error 0 cee eee ees 22 2 2 2 Speed errora d teas ave Aa eu Tu S ehe Date ba E M a AN dea 24 2 2 2 1 Speed error table 1 4 segue er relies eeepc bees e backed ded bon te i due 26 3 Operating conditions requiring attention lisse 30 3 1 Operating conditions requiring attention their causes and whatto do 31 3 1 1 Operating condition 1 Fan failure tees 33 3 1 2 Operating condition 2 Heater failure 2 1 eee 34 3 1 3 Operating condition 3 Supporting liquid gt 60 C 2 kee 34 3 1 4 Operating condition 4 Supporting liquid level too low and its immediate BNET pm 35 3 1 4 1 With switching off the gyro compass sssssseeee I 35 3 1 4 2 Without switching off the gyro compass sseeeeee nennen 39 3 1 5 Operating condition Voltage cut off 2 22 cee 42 4 Adertignallirig iue tpa ro mena dee Cpu e CHE Cae I a CH Be EEK eRe 43 5 Switching off the Gyro Compass 00 cece eee eee nh 46 6 Maintenant esce odo ie at En Gand EA EOS MATER ERIS 47 Edition February 2015 4201 DOC010102 Operator manual Compass Standard 22 and Standard 22 Compact The above mentioned standards require a new alert philosophy called Bridge Alert Management The Standard 22 gyro compass is compliant to such standards in combinatio
12. Z Standard 22 Standard 22 Compact Example of heading calculation Latitude 55 55 Speed 16 Kts 16 Kts True heading 345 1 7 343 3 223 7 1 3 225 Example of a bearing Compass heading 255 Latitude 55 Speed 16 Kts Direction of bearing 135 Correction value as per table 0 5 True bearing 135 0 5 135 5 The following statement applies The TRUE HEADING is always to the west of the compass heading N Compass headin i W lt E true heading S t 25 4102 D0C010102 Edition February 2015 Operator Manual Compass Standard 22 and Standard 22 Compact 2 2 2 1 Latitude in Speed error table north south Headings in Speed in Kts sign for correction value 4201 D0C010102 26 Edition February 2015 Operator Manual O Compass ne 22 ANSCH TZ Standard 22 Standard 22 Compact north south Latitude Headings in Speed in Kts in sign for correction value Edition February 2015 27 4102 D0C010102 Operator Manual Compass Standard 22 and Standard 22 Compact north south Latitude Headings in Speed in Kts in sign for correction value 4201 D0C010102 28 Edition February 2015 Operator Manual O Compass ne 22 ANSCH TZ Standard 22 Stand
13. ard 22 Compact north south Latitude Headings in Speed in Kts in sign for correction value Edition February 2015 29 4102 D0C010102 Operator Manual Compass Standard 22 and Standard 22 Compact Operating conditions requiring attention An operating condition that indicates a malfunction but has no immediate effect on the heading output is indicated by a flashing decimal point It is not necessary to acknowledge such a condition on the compass The flashing decimal point remains until the malfunction has been corrected The heading indicated on the digital display unit is not affected EXCEPT for Voltage cut off see section 3 1 The flashing decimal point remains until the malfunction has been corrected Decimal point flashes on the digital display unit Please pay special attention when the compass housing is opened Risk of electric shock In opened devices voltages representing a risk of electric shock are applied Please note that the compass does not meet its specified environmental requirements such as Internal Protection IP electromagnetic compatibility EMC and vibration with an opened housing A flashing decimal point in the seven segment display indicates an operating condition where the operation of the gyro equipment is not restricted The operating condition needs to be checked Call an authorized service station if requ
14. ature of the supporting liquid it should switch on when the supporting liquid reaches 51 C Whether the fan is operational or not is registered from the fan s current consumption it therefore follows that the fan is defective if this condition is displayed To prevent overheating due to fan failure it is recommended that you do the following Check whether the fan screen is covered and check to see that air can enter the enclosure unhindered at the base f necessary cool the outer sphere using an external fan Continue this until operating condition 1 stops It is essential that the fan be replaced at the earliest opportunity NOTE A critical situation occurs if the ambient temperature is extremely high and condition 3 is displayed Temperature of supporting liquid more than 60 C Constant high temperature may effects to the life cycle of the gyro compass A higher temperature for a short moment has no importance Edition February 2015 33 4102 D0C010102 Operator Manual Compass Standard 22 and Standard 22 Compact 3 1 2 3 1 3 Operating condition 2 Heater failure This condition is output when the heater 45 C has failed Compass operation is not restricted if the temperature is more than 45 C see also fan failure A temperature drop down below 45 C leads to an error message Error and the heading information will not longer displayed as well as the heading information to the connecte
15. d heading receivers To prevent the supporting liquid from cooling further it is recommended that to do the following Close the door on the compass or introduce warm air These measures should be continued until condition 2 stops It is essential that the heater be repaired at the earliest opportunity Operating condition 3 Supporting liquid gt 60 C This condition is output when the temperature of the supporting liquid is higher than 60 C To prevent the temperature from rising further it is recommended that you do the following Open the door on the compass f necessary cool the outer sphere using an external fan Check the ambient temperature If the ambient temperature is higher than 60 C steps should be taken to cool it down These measures should be continued until condition 3 stops If condition 3 is displayed in combination with condition 1 the fan must be replaced at the earliest opportunity See also condition fan failure 4201 D0C010102 34 Edition February 2015 Operator Manual O Compass Standard 22 Compass and ANSCHUTZ Standard 22 Standard 22 Compact 3 1 4 3 1 4 1 Operating condition 4 Supporting liquid level too low and its immediate measure This condition is output when the level of the supporting liquid in the outer sphere is too low The supporting liquid level is determined by an immersion probe installed in the upper part of the outer sphere There are
16. ding correction The information given here in particular with regard to Speed Error Correction applies in general to the STD 22 Compact compass and the STD 22 compass Where there is an exception your attention is drawn to this The heading has to be corrected acorrection depending on the alignment error acorrection depending on a speed error 2 2 1 Alignment error The alignment error A error occurs if the compass was not correctly aligned when it was installed i e when the compass zero line does not agree with the ship s line pre alignment An alignment error can be corrected at max 5 h after switching on and or max 5 h when the ship is moored by making readjustments see also service manual To try to perform a readjustment within this 5 hours will lead to a displayed message AL no after pressing the button B38 or B39 it means actually no readjustment possible Edition February 2015 21 4102 D0C010102 Operator Manual Compass Standard 22 and Standard 22 Compact 2 2 1 1 Procedure for setting the compass zero A error Display Button B38 B37 DIP switch Button B39 Figure 12 Arrangement of operating elements inside the compass Remove the cover of the compass unfasten the 5 cross slotted screws Move switch B37 DIP switch contact 1 to the OPEN position The digital indicator is now indicating ALEr Alignment Error Press button B38 or B39 until the heading you require displays
17. ion February 2015 1 4102 DOC010102 Operator Manual Compass Standard 22 and Standard 22 Compact STD 22 Compact as a stand alone system Inputs GPS positioning data Speed data from the GPS Speed from the Pulse Log Direction of speed from the Pulse Log NMEA 24V d c voltage supply Outputs 2x Heading course bus or NMEA designated CHn 1 and CHn 2 1x Heading course bus Status signals SEC speed error correction System Available Optional feature Additional Output Box 146 103 Input gt 1 x Heading course bus Outputs SSC Interface Step 6 steps degree NMEA superfast 50Hz Functions ntegral Speed Error Correction SEC Optional feature Quick Settling with the Operator Unit for Quick Settling STD 22 with other system components Distribution Unit NG002 003 and Operator Unit Inputs via the Distribution Unit only through a CAN bus data bus system GPS positioning data Speed data from the GPS Speed from the Pulse Log Leading sign for the speed from the Pulse Log NMEA 24V d c voltage supply DV bus alternative inputs for speed position at the Distribution Unit Optional feature Other non Raytheon Ansch tz heading sensors can be connected to the Distribution Unit Outputs at STD 22 compass 2x Heading course bus or NMEA 1 x Heading course bus Status signals SEC speed error correction System Available Heading Course
18. ion the compass heading is continually corrected using the values shown in the speed error table see section 2 2 2 1 The digital display on the compass and the connected repeater displays will always indicate the true corrected heading For automatic speed error correction the ship s speed and the latitude are read into the gyro compass The speed error correction function on the STD22 Compact Gyro Compass Only the automatic speed error correction function applies in order for it to operate GPS or Pulse Log and GPS data speed and degree of latitude must be supplied to the compass CAUTION If the speed and latitude are not available for automatic speed error correction Pulse Log or GPS failure no automatic correction can take place The gyro compass will be showing the uncorrected value The speed error correction function on the STD22 Gyro Compass In this version besides the automatic speed error correction function with GPS and Log data the speed error correction function can also be carried out with manual speed and latitude values input manually The speed error can be corrected manually on the Operator unit by entering the speed and latitude manually see also Manual of Operator Unit 130 626 Add the correction value taken from the table to the uncorrected heading making sure you note the leading sign 4201 DOC010102 24 Edition February 2015 Operator Manual O Compass Standard 22 Compass and ANSCHUT
19. ip observe the heading for a while 30 minutes because of stimulation of the gyrosphere caused by a slight unintentional horizontal inclination After this procedure is finished it is strongly recommended to Edition February 2015 41 4102 DOC010102 Operator Manual Compass Standard 22 and Standard 22 Compact 3 1 5 Operating condition Voltage cut off This operating condition is output if the supply voltage is cut off for a short time The cut off period is determined by the fall in supporting liquid temperature If the temperature falls below 45 C the compass recognises that the voltage supply has been switched off in the conventional way In the case of a voltage cut off supporting liquid temperature does not fall to below 45 C and the voltage supply has been restored the settling stage in indicated again see also section 2 1 1 Compass indications during the settling stage Note Heading indication can be incorrect Wait for a complete follow up Check voltage supply to the gyro compass Figure 19 Digital display for Voltage cut off If voltage cut offs occur often the following checks should be made check the on board power supply or check the the on board power supply distribution unit compass cable connections or check the the on board power supply AC DC converter compass cable connections 4201 DOC010102 42 Edition February 2015 Operator Manual O Compass S
20. ired 4201 D0C010102 30 Edition February 2015 Operator Manual O ompass Com aie ral 22 ANSCH TZ Standard 22 Standard 22 Compact 3 1 Operating conditions requiring attention their causes and what to do There are five different operating conditions requiring attention numbered 1 to 6 6 is not used These are displayed on the compass s digital display after the B38 or B39 buttons have been pressed once 1 to 3 are displayed when button B39 is pressed and 4 6 are displayed when button B38 is pressed If several conditions occur at the same time all are displayed The following operating conditions can be displayed 1 fan failure N 2 heater failure st e Button B39 3 supporting liquid temperature is higher than 60 C N 4 supporting liquid level is too low 5 after voltage cut off Button B38 6 not used Edition February 2015 31 4102 D0C010102 Operator Manual Compass Standard 22 and Standard 22 Compact Examples of conditions XII gt HM Condition 4 d I E C4 Conditions C5 4 and 5 B38 OPEN EI Ner Condition 1 12345678 Figure 14 How to display information about operating conditions 4201 D0C010102 32 Edition February 2015 Operator Manual O Compass Standard 22 u and ANSCHUTZ tandar Standard 22 Compact 3 1 1 Operating condition 1 Fan failure This condition is generated if the fan does not switch itself on as a result of the temper
21. it down Caution Handling of the outer sphere should be performed to the greatest possible extent in a horizontal position 4201 D0C010102 40 Edition February 2015 Operator Manual O Compass Standard 22 Compass and ANSCHUTZ Standard 22 Standard 22 Compact Open the ventilation outlet Figure 15 1 the supporting liquid screw Figure 15 3 and the distilled water screw Figure 15 2 Fill in distilled water only distilled water from Raytheon Anschutz part number 148 398 one 230cm bottle into the inlet for supporting liquid until the measuring cone shows Level O K see Figure 16 Fill in the remaining content of the bottle into the inlet for distilled water until the Dip Stick shows a level according to Figure 17 Close all in and outlets if applicable use new sealing rings Place the outer sphere in the compass enclosure Pay attention to the two locking pins on the closure Hold the outer sphere with both hands and guide it under the snap closures on the pendulum joint Using the thumbs press down and engage the two snap closures Carefully turn the outer sphere through 90 and repeat the process with the other two snap closures The outer sphere is now fastened to the pendulum joint Switch on the follow up function again DIP switch 7 into the lower position see Figure 18 Close the door of the enclosure and fasten it with screws paying attention to the earthing str
22. lluminates if the Quick Settling function is active Installation and assembly instructions are in the Service section of this manual 4201 D0C010102 6 Edition February 2015 Operator Manual O Compass Standard 22 MT and ANSCHUTZ tandar Standard 22 Compact 1 1 2 2 1 1 2 3 AC DC converter 121 062 The AC DC converter is supplied with 115 to 230 V AC on the input side and delivers 24 V DC as output voltage with a maximum output power of 240 W see separate manual no 4175 Figure 4 AC DC Converter 121 062 Additional Output Box 146 103 not illustrated This connection box is used to convert the serial course bus into a Fast NMEA data format The connection box is connected to the 24 V d c power supply Edition February 2015 7 4102 D0C010102 Operator Manual Compass Standard 22 and Standard 22 Compact 1 2 STD 22 Gyro Compass In this application the gyro compass is operated on a bus system CAN bus With this application there are more extended options for connecting external equipment and considerably more heading receivers can be operated This application needs to be equipped with a minimum of a type 130 626 Operator Unit and a type 138 118 NG002 003 Distribution Unit A magnetic sonde can be connected directly to the Distribution Unit Gyro compass Speed and position for Individual Speed Error Correction Other heading sensors Distribution unit Type 138 118 12
23. ly Gyrosphere packed separately Gyro compass with outer sphere distilled water and Tool and spare parts pack supporting liquid User and service manual Figure2 STD 22 Compact Gyro Compass Scope of Supply Edition February 2015 5 4102 D0C010102 Operator Manual Compass Standard 22 and Standard 22 Compact 1 1 2 STD 22 Compact Gyro Compass optional features 1 1 2 1 Quick Settling operator unit The Quick Settling function reduces the time the compass requires to settle to approximately one hour The most recent heading is stored when the gyro compass is switched off When it is switched on the compass uses that value to make a default setting so that the settling time is reduced The Quick Settling function can only be used if the ship s heading has not been changed between switching off and switching back on The Quick Settling function can not be used During the first setting up installation Ifthe ship s position was changed between switching off and on again of the compass If the temperature of the gyro supporting liquid is more than 30 C Quick Settling Illuminated push button Quick Settling ON Running Set e Figure 3 Controls and indicators on the Quick Settling Control Unit The Quick Settling ON button activates this function Flashes if it is possible to activate this function It flashes for maximum 3 minutes
24. m a service within the next 6 months to check the compass Caution This measure is an exception to restore operation Caution Due to condition 4 we advice to arrange a service for a routine check during the next port stay to be on safe side Caution This measurement must be performed very carefully and ideally under calm sea conditions Edition February 2015 39 4102 D0C010102 Operator Manual Compass Standard 22 and Standard 22 Compact It is not necessary to switch off the gyro compass for this measurement Undo the two screws at the top and the bottom of the door of the gyro compass enclosure and lift out the door paying attention to the earthing strip Switch off the follow up function see Figure 18 This must be done to prevent a twisting of connected cables no plugs must be disconnected B37 DIP switch DIP switch 7 Figure 18 Arrangement of DIP switch Set DIP switch 7 into the upper position the follow up function is stopped Place both hands under 2 of the 4 snap closures and release them by pressing with the thumbs Carefully turn the outer sphere through 90 and repeat the process with the other two snap closures The outer sphere is now free except connected cables and can be removed Still holding the outer sphere with both hands lower it tightly This releases the locking device carefully remove it out of the compass enclosure as far as the cable length and set
25. n with Operator Unit Gyro type 130 626 NG00x Please refer to the manuals of Operator Unit Gyro type 130 626 NG00x for any details about the alert handling and presentation For new installations it is recommended to make use of new alert management gt PP Alert outputs must be connected to a central Alert Panel Signal Unit Alert Panels or Signal Units must have an acoustical and optical alert indication Make sure that alerts are presented at the conning position Maintenance and repair work or any other work performed on the gyro compass should be carried out only by trained and qualified staff who are well versed in national safety regulations After the gyro compass has been switched off it is necessary to wait at least 15 minutes before accessing the interior of the gyro compass Otherwise the sphere could be damaged A flashing decimal point in the seven segment display indicates an operating condition where the operation of the gyro equipment is not restricted The operating condition needs to be checked Call an authorized service station if required Refer to chapter 3 for further details Please note that all ships of 500 Gross tonnage and upwards according to SOLAS regulations must be with a gyro compass The Gyro compass must be operational For this reason it is not allowed to have a switched off gyro compass during voyages A switched off gyro compass during voyages could damage to the Gyrosphere 4201 DOC101
26. pass and other non Raytheon Anschuetz heading sensors Edition February 2015 9 4102 D0C010102 Operator Manual Compass Standard 22 and Standard 22 Compact Voltage is supplied to the gyro compass via the Distribution Unit or is directly connected to the compass itself There are separate manuals for the Operator Unit and for the Distribution Unit The Quick Settling function is activated via the Operator Unit The automatic Speed Error Correction function is available only when a GPS NMEA speed and NMEA position or Pulse Log and a NMEA position is connected The relevant data must be supplied via the Distribution Unit Manual Speed Error Correction SEC is applicable by manual input of speed and position at an Operator Unit 4201 DOC010102 10 Edition February 2015 Operator Manual O Compass Standard 22 Compass ANSCH TZ and Standard 22 Compact Standard 22 1 2 1 STD 22 Gyro Compass Scope of Supply Gyrosphere packed separately Gyro compass with outer sphere distilled water and Tool and spare parts pack supporting liquid l Operator and Service manual Operator Unit 130 626 Distribution Unit 138 118 with manual NG002 003 with manual Figure 6 STD 22 Gyro Compass Scope of Supply Edition February 2015 11 4102 DOC010102 Operator Manual Compass Standard 22 and Standard 22 Compact 1 2 2 Optional features for the STD 22 Gyro Compass 1 2 2 1 AC DC converter 121 06
27. put NMEA according to IEC 61162 1 Log input NMEA according to IEC 61162 1 Indicator precision 4 digit digital display Resolution 0 1 Heading accuracy Settle point error 0 1 x secLAT RMS Static error 0 1 x secLAT RMS Dynamic error 0 4 x secLAT RMS periodic roll and pitch horizontal acceleration secLat 1 cosLatitude Follow up up to 100 sec 4201 DOC010102 14 Edition February 2015 Operator Manual O Compass ne 22 ANSCH TZ Standard 22 Standard 22 Compact Controls and Indicators on the Gyro Compass The user information stated here applies equally to the STD 22 Compact Gyro Compass and the STD 22 Gyro Compass Viewed from above see Figure 8 Digital indication of the following Compass heading Operating status Operating conditions requiring attention Error messages Compass heading Operating status heating with current temperature Operating condition requiring attention flashing Error message Figure 8 The indicators on the gyro compass with examples of the type of indication Edition February 2015 15 4102 D0C010102 Operator Manual Compass Standard 22 and Standard 22 Compact After removing the cover Do not touch live parts Neither the DIP switches nor the buttons are live A DIP switch B37 and two push buttons B38 and B39 are used to adjust the settings as follows Heading and correction data Settings for f
28. r 4 hours after switching on with Quick Settling this is 1 hour Heading indication still inaccurate Heading indication can be used flashing Quick Settling function is activated Note If the Quick settling function is activated the heading to which it will followed up is displayed Figure 11 Indications during the settling stage Edition February 2015 19 4102 D0C010102 Operator Manual Compass Standard 22 and Standard 22 Compact 2 1 3 Overview of indications digital display during operation Once the compass is switched on the digital display indicates as follows Indications Comments Information Heating stage Example The temperature of the supporting liquid is displayed during the heating stage Example h p B H h 28 8 28 8 C heating stage Settling stage Example The gyro compass is settling in The heading is indicated with an illuminated dot after the last figure during the settling stage approx 4 hours The heading value is still not accurate Heading indication Example Once the settling process has ended Heading accuracy 4 hours after switching on is better than 2 or with Quick Settling 1 hour after switching on is better than 3 Approximately 5 hours after switching on 0 4 dynamic 0 1 static 4201 D0C010102 20 Edition February 2015 Operator Manual O Compass Standard 22 u and ANSCHUTZ tandar Standard 22 Compact 2 2 Hea
29. sphere and note their location Carefully turn the outer sphere through 90 and repeat the process with the other two snap closures The outer sphere is now free and can be removed Still holding the outer sphere with both hands lower it slightly this releases the locking device carefully remove it from the compass enclosure and set it down Open the ventilation outlet Figure 15 1 the supporting liquid screw Figure 15 3 and the distilled water screw Figure 15 2 Fill in distilled water only distilled water from Raytheon Ansch tz part number 148 398 one 230cm bottle into the inlet for supporting liquid until the measuring cone shows Level O K see Figure 16 Fill in the remaining content of the bottle into the inlet for distilled water until the Dip Stick shows a level according to Figure 17 Close all in and outlets if applicable use new sealing rings Place the outer sphere in the compass enclosure Pay attention to the two locking pins on the closure Hold the outer sphere with both hands and guide it under the snap closures on the pendulum joint Using the thumbs press down and engage the two snap closures Carefully turn the outer sphere through 90 and repeat the process with the other two snap closures The outer sphere is now fastened to the pendulum joint Fix all connections cables that lead to the outer sphere as notes before Close the door of the enclosure and fasten it with screws paying at
30. tandard 22 u and ANSCHUTZ tandar Standard 22 Compact Alert signalling Alerts are indicated on the compass as follows The heading is not displayed and not output to the connected heading receivers An alert signal is indicated on the digital display by means of a flashing Erro for Error flashing OFF flashing OFF occurs only when the voltage is too low After the blinking Erro the compass internal PC board which fails and an error code is displayed detailed information see Service manual AN lt Erro WY Sy ve Figure 20 Digital display for error indication Edition February 2015 43 4102 DOC010102 Operator Manual Compass Standard 22 and Standard 22 Compact Nu Button B38 B37 DIP switch Button B39 Figure 21 Operating elements on the compass after removing the cover The following failed PC boards are possible PCbP power PCB faulty PCbS sensor PCB faulty PCBC connection PCB faulty PCbG outer sphere PCB faulty See the service manual for more details 4201 DOC010102 44 Edition February 2015 Compass Standard 22 Operator Manual O Compass ANSCH TZ and Standard 22 Compact Standard 22 Comment Serial connection of sensor PCB to power PCB faulty Inductive transmission faulty System voltage B5 5 B5 8 on power PCB faulty Encoder voltage faulty System voltage B5 1 B5 4 on power PCB faul
31. tention to the earthing strip When the power supply is switched on the compass is ready for use again Run the heating and settling in stages as described in section 2 1 4201 D0C010102 36 Edition February 2015 Operator Manual O Compass Standard 22 Compass and ANSCHUTZ Standard 22 Standard 22 Compact distilled water Figure 15 Immediate measure to fill up with distilled water Level OK at operational temperature appr 50 C Level too low Figure 16 Measuring cone top view Edition February 2015 37 4102 D0C010102 Operator Manual Compass Standard 22 and Standard 22 Compact max Level of dist water 230c03 Lift s2mm min Level of dist woter S0cm View A Measurement of Level of distilled water View B Measurement of Height of Gyrosphere Figure 17 Dip Stick levels 4201 DOC010102 38 Edition February 2015 Operator Manual O Compass Standard 22 Compass ANSCH TZ Standard 22 and Standard 22 Compact 3 1 4 2 Without switching off the gyro compass The measure below does not compensate the planned replacement of the supporting In certain circumstances if the level of the supporting liquid falls suddenly you must establish the cause possibly a leak and correct the fault If the level of supporting liquid is too low the compass can be destroyed Immediate measure Caution It is strongly recommended to perfor
32. titude from GPS receivers NMEA resp from the Pulse Log Edition February 2015 3 4102 D0C010102 Operator Manual Compass Standard 22 and Standard 22 Compact Quick Settling operator unit Option This function can be used to reduce the time between switching on the compass and indicating outputting a valid heading value to one hour with a precision of 3 In the STD 22 Compact this function is activated from the QS Operator Unit 130 606 NGO01 in the STD22 this function is activated from the Operator Unit 130 626 The Compact STD 22 gyro compass consists of the 110 233 NG002 gyro compass the 111 006 gyrosphere Optional features QS Operator Unit 130 606 AC DC converter 121 062 Additional Output Box 146 103 The Speed Error Correction function is available only when a GPS or Pulse Log is connected The output interfaces on the STD 22 Compact are as follows Heading corrected SEC as NMEA or course bus Status signals alerts error messages Optional via the Additional Output Box box NMEA superfast 50Hz Step 6 steps degree SSC The input interfaces on the STD 22 Compact are as follows NMEA Position NMEA Speed Pulse Log Direction Pulse Log Status signals or pulses 4201 D0C010102 4 Edition February 2015 Operator Manual O Compass nee 22 ANSCH TZ Standard 22 Standard 22 Compact 1 1 1 STD 22 Compact Gyro Compass Scope of Supp
33. ty Encoder faulty CAN dialogue from gyro card to sensor PCB faulty Follow up system faulty CAN1 and CAN2 operating voltage faulty Supporting liquid error System voltage B21 5 B21 8 on outer sphere PCB faulty Operating voltage 24V faulty Operating voltage 15V faulty Heating operating voltage B21 1 B21 4 faulty Operating voltage 72V faulty Operating voltage 78V faulty for 400 Hz Gyro supply 55V faulty Gyro current faulty Pump voltage faulty Pump current faulty Temperature sensor faulty Serial interface MC1 to MC2 faulty CAN interface from sensor PCB to outer sphere PCB faulty Heating system faulty Watchdog counter Power ON counter OFF status counter Operating condition Fan failure Operating condition Heater failure Operating condition Supporting liquid gt 60 C Operating condition Supporting liquid too low Operating condition Voltage cut off Edition February 2015 45 4102 DOC010102 Operator Manual Compass Standard 22 and Standard 22 Compact Switching off the Gyro Compass The gyro compass is switched off by switching off the power supply Caution Maintenance and repair work should be carried out only by trained and qualified staff who are well versed in national safety regulations e After the gyro compass has been switched off it is necessary
34. unctional checks System settings such as data formats or transmission speeds Only authorised personnel are authorised to change system settings Please observe the relevant instructions in the service manual Button B38 B37 DIP switch Button B39 Figure 9 Operating elements on the compass after removing the cover 4201 D0C010102 16 Edition February 2015 Operator Manual O ompass Com aie ral 22 ANSCH TZ Standard 22 Standard 22 Compact 2 1 Switching on the STD 22 Compass The compass goes into operation when the power supply is switched on from the ship s mains The compass goes into the heating stage for the first 30 minutes this period will vary depending on the temperature of the supporting liquid and the letter h is displayed as the leading sign on the digital display The follow up system is switched off no heading can be output When the temperature of the supporting liquid reaches 45 C the follow up system switches on automatically and the heading is displayed on the compass however deviation from actual heading may still be considerable This settling phase indicated by an additional dot on the digital display ends 4 hours after switching on Accuracy is now lt 2 No NMEA Heading and NMEA RoT is displayed output during the settling stage After about five hours from switching on the compass shows an accurate heading see Technical Data section 1 3 3 The
Download Pdf Manuals
Related Search
Related Contents
GUIDA DELL`UTENTE Basic Operation Guide 取扱説明書 Samsung MS28 Solo MWO with Healthy Steam, 28 L User Manual DENTOCEM concentric type (soft seated) butterfly valve maintenance データつながる、広がる Roland SONAR re-150 User's Manual XciteRC Tiger I FAR BRETON BRETON CUSTARD FLAN PATISSERIE Copyright © All rights reserved.