Rev. H - Operator`s Manual - Commercial Wheelchair Lifts

image

Contents

1. a latssi produsi information available 8 SASE Wels Sel 5023 rijit 9 sangas ai any tine without notices 30651 Rev H December 2009 Tne Braun Corporiiior
2. 57 Outer barrier is not up and latched and ground detect switch did not deactivate Contury and Vista only 58 Outer barrier is not up and latched and the platform is 3 above the groun 59 Outer barrier is not up ater pe platlorm ravel 60 The kickout gas springs are wom replace betore using 75 Low voltage detected must tum off power switch to reset LCD 77 Vehicle secure interlock has not been activated 20 Position wi be set if you keep holding the button until it beeps Position is out of a predetermined acceptable range o floor position 92 Bridge switch is not made needs adjusting inner rollstop occupied switch is not mado position needs to be moved or switch Should be adjusted 34 Outer barrier is not made fix and try again 95 Outer barter latch is not made check for Jumper on Century and Vista lits check latch on Milennium its Controller program is not valid replace controller Flashing Numbers Fi lasting 65 Unfold button is pressed Bridge switch is activated Outer barrier latch switch i activated Ground detect switch is activated Flashing 72 Outer barrier up switch is activated Flashing 73 Inner rolistop up switch is activated Flashing 74 Inner olstop occupied switch s activated Flashing 76 Outboard barrier occupied switch is activated Flashing 78 Threshold tape switch A is activated Flashin
3. Yellow platform loading boundar ies are identified in the following manner The yellow powder coated inner roll stop and outer barrier identify the inboard and outboard ends of the platform A yellow powder coated guard is lo Operation Notes and Details cated on the pump side platform side plate A yellow boundary strip decal is affixed to the op posite platform side plate Yellow plastic caps are placed on the dual handrails The threshold warning plate is powder coated yellow to identify the platform threshold area Interlock A visible and audible threshold warning system will ac tivate if the threshold area is oc cupied when the platform is one inch or more below floor level The attendant must always be certain the wheelchair passenger or standee is properly positioned on the platform fully inside yel low boundaries and the wheel chair brakes are locked when a passenger is on the lift platform The lift passenger must keep hands arms and all other body parts within the lift occupant area and clear of all moving parts Vehicle Floor Level Loading and Unloading The platform must be fully raised at floor level and the bridge plate must be properly positioned when loading or unloading passengers in or out of the vehicle It is the responsi bility of the lift attendant to ensure the platform and the bridge plate are properly positioned at floor level when loading and unloading passengers
4. AWARNING Whenever a passenger is on the platform the Passenger must be positioned fully inside yellow boundaries Wheelchair brakes must be locked e Inner roll stop and outer barrier must be UP Failure to follow these rules may result in serious bodily injury and or property dam age Page 23 Operation Notes and Details Lift Passengers continued The wheelchair brakes must be locked the outer barrier must be in the fully up vertical position and the outer barrier latch must be fully engaged whenever a passenger is on the platform Do not use the outer barrier as a brake Stop and brake the wheelchair when fully loaded on the platform Manually stop and brake manual wheelchairs Stop powered wheelchairs with the wheelchair controls Turn powered electric wheelchairs off when on the platform If the outer barrier inner roll stop handrails or any other lift component does not operate as Page 24 outlined in this manual discon tinue lift use immediately and contact The Braun Corporation sales representative in your area or call The Braun Corpora tion at 1 800 THE LIFT One of our national Product Support representatives will direct you to an authorized service techni cian who will inspect your lift AWARNING Discontinue lift use immediately if any lift component does not operate prop erly Failure to do so may result in serious bodily injury a
5. Read warnings and operate LIFT 21494 LIFT POWER ON Lift installation and servicing prohibited by anyone who has not been certified by The Braun Corporation Sales and Service School Certified service technicians should call 1 800 THE LIFT to receive applicable installation service manual TO STORE PUMP HANDLE 1 Insert bottom of handie behind bottom clip 2 Rotate clip to lock OFF Fail follow this policy may result in serious CLOSE DOOR S bodily injury and or property damage DOT Public Use Lift SERIES DOT Public Use Lift 25675 Page 38 Decals and Antiskid Decals 32410 LCD Lift Codes Listed below are codes that the lit controller outputs during Mt operation The codes wil be displayed on an LCD screen located on the Ift contro board inside the pump module Non Flashing Numbers 01 Platform stowed 02 Platform unfolding 03 Platform unfolding paused 04 Platform at foor level 05 Platform beginning to lower 06 Platform towering thrashoid cannot be occupied from this point down 07 Outer barrier moving to horizontal positon Platform at ground level 09 Outer barrier moving to vertical position 10 Platform raising 11 Platform raising paused at tloor 12 Platform folding imited pressure
6. 2 LO Parallel Arm Pivot Pins 8 LO Lubrication Diagram Lift Tite Latch Dampening Spring 2 springs 4 Points LO Parallel Arm Pivot Pins 8 LO Handrail Pivot Pins 2 LO Inner Roll Stop IB Pivot Points LO Rotating Pivot Slide Arm UHMW Slide 4 DE Rotating Pivot Slide Arm Pivot Pins LO Outer Barrier Hinge Pivot Points 2 LO Platform Fold Axles 2 LO Platform Pivot Pin 2 Points LO Lift Tite Latch Roller Assemblies 2 LO Outer Barrier Latch LO Outer Barrier Latch Lever I LO Page 43 Page 44 Maintenance and Lubrication Schedule Outer barrier hinge pivot points 2 Outer barrier latch pivot slide points Outer barrier latch lever pivot points Lift Tite latches tower pivot points 2 Lift Tite latch gas dampening spring pivot points 2 springs 4 points Inspect Lift Tite latches and gas springs for wear or damage bent deformed or misaligned posi tive securement external snap rings and proper operation Inspect outer barrier for proper operation Inspect outer barrier latch for proper operation positive securement and detached or missing spring Adjust fold pressure and outer barrier fold pressure if applicable Verify NHTSA Operations Checklist Apply Light Oil See Lubrication Diagram Apply Light Oil See Lubrication Diagram Apply Light Oil See Lubrication Diagram Apply Light Oil See Lubrication Dia
7. Operation Notes and Details Lift Features continued Inner Roll Stop NL Series lift models are equipped with an automatic inner roll stop that also serves as the bridge plate inner roll stop photos below When the UNFOLD switch is Page 18 pressed and the platform unfolds from stow position to floor level this mechanical roll stop is auto matically deployed to the bridging horizontal position to provide a bridge plate between the platform and the lift base plate vehicle floor The inboard edge of the bridge plate rests on the threshold warning plate base plate The roll stop automatically folds rotates to the vertical roll stop position when the platform lowers to the ground DOWN switch is pressed As the UP switch is pressed and the platform raises from ground level the inner roll stop automati cally unfolds rotates to the Fully Deployed Fully Unfolded vertical horizontal Inner Inner Roll Stop Roll Stop bridging position Inner Roll Stop The inner roll stop must overlap the base plate a minimum 1 2 Operation Notes and Details AWARNING Discontinue lift use immediately if any lift component does not operate prop erly Failure to do so may result in serious bodily injury and or property damage horizontal bridging position when it reaches vehicle floor lev el The roll stop must overlap the lift base p
8. barrier when the barrier rotates previous page upward from ramp position to Discontinue lift operation immedi the vertical position UP switch Interlock Lift platform move ately if the outer barrier does not is pressed to raise the platform ment shall be interrupted unless operate properly above ground level Note The the outer barrier is raised verti platform must raise approximately cal position and the outer barrier Outer Barrier Latch A spring three inches before the latch latch is positively engaged loaded latch engages the outer engages fully see photos on Fully Engaged Outboard Barrier Latch Fully Unfolded Barrier Ramp position Fully Folded Disengaged B Outer Barrier Outer Barrier Up vertical Latch Outer Barrier Note Platform must raise approximately three inches Latch Foot before latch engages fully Page 20 Operation Notes and Details The latch disengages the barrier when the platform lowers fully reaches ground level and the latch foot contacts the ground latch raises above the barrier Outer Barrier and Latch Op eration The lift attendant must press the DOWN switch to lower the platform fully to the ground The attendant must view the platform as it lowers to be certain the entire platform reaches and rests safely on the ground Stop pressing the DOWN switch if any portion of the platform is ob structed while descending or the entire platform does not reach ground level
9. Safety The lift operator must ensure that lift occupants attendant and bystanders must passengers keep hands arms keep clear of the area in which and all other body parts within the lift operates and clear of all the lift occupant area and clear of moving parts Lift attendants moving parts Control Switches Lift Power ON OFF Switch This switch must be in the ON position in order to activate the ES lift The green Power Indicator e FEN Light mounted on top of the pump module illuminates to signal power Hand held Pendant to the lift FOLD UNFOLD Hand held Pendant Conirol Simply press the switch labeled The hand held attendant s for the intended function pendant control is equipped with two rocker switches UNFOLD FOLD DOWN and UP The momentary switches activate the automatic lift functions Page 15 Operation Notes and Details Lift Features Become familiar with all lift for identification of specific lift information is not understood features and the proper opera components if not clearly depict tion of the lift components before ed in this section Contact The Lift Tite Latches NL Series attempting lift operation Refer to Braun Corporation at 1 800 THE lifts are equipped with Lift Tite the Lift Terminology Illustrations LIFT immediately if any of this Latches Lift Tite Latches pre Latch En gagement Pin Roller AWARNING Engaged Discontinue lif
10. manual operation of the lift in event of power or equipment failure Terminology Become famil iar with the terminology that will be used throughout this man ual Become familiar with the identification of lift components and their functions Contact your lift sales representative or call The Braun Corporation at 1 800 THE LIFT if any of this information is not fully under stood Direction The terms left right inboard and out board will be used throughout this manual to indicate direc tion as viewed from outside the vehicle looking directly at the lift Refer to the Lift Termi nology Illustrations for clarifica tion of direction terms Page 5 Lift Components Refer to the Lift Terminology ll lustration on page 4 Pump Module The lift mounted pump module consists of the hy draulic pump the manual hand pump the electronic control board and electrical components that power the lift electric hy draulic systems Hand held Pendant Control The hand held attendant s pendant control is connected to the pump module The hand held pendant is equipped with two rocker switches UNFOLD FOLD DOWN and UP The momentary switches activate the automatic lift functions Page 6 Lift Terminology Lift Frame The lift frame con sists of the base plate threshold warning plate towers parallel arms vertical arms platform pivot arms and handrails Two main hydraulic cylinders are housed i
11. on pages 41 49 of this manual Refer to the Maintenance and Lubrication section for further details AWARNING Maintenance lubrication procedures must be performed by authorized service personnel as specified in this manual Failure to do so may result in serious bodily injury and or property AWARNING Read and become familiar with all lift operation safety precautions opera tion notes and details operating instructions and manual operat ing instructions prior to operating the lift If this information is not fully understood contact The Braun Corporation immedi ately Failure to do so may result in serious bodily injury and or property damage Whenever a passenger is on the platform the e Passenger must be positioned fully in side yellow bound aries Wheelchair brakes must be locked Inner roll stop and outer barrier must be UP Failure to follow these rules may result in serious bodily injury and or property damage Lift Operating Instructions AWARNING Before lift operation park the vehicle on a level surface away from vehicular traffic Place the vehicle transmission in Park and engage the parking brake Vehicle engine must be running Lift Operating Instructions photos depict lift model NL9171B Instructions and procedures are applicable for all NL Series lift models Lift posted Warnings and Lift Operating
12. other party other than Braun normal wear tear usage maintenance service periodic adjustments the effects of condensation or moisture from condensation mold or any damage caused by mold imperfections that do not affect the product for its intended purpose items that are working as designed but that you are unhappy with problems related to mis operation misuse mishandling neglect or abuse including failure to main tain the product in accordance with the owner s manual or other routine maintenance such as inspections lubricating adjustments tightening of screws sealing wheel alignments or rotating tires damage due to accident or collision including any acts of weather or damage or corrosion due to the environment theft vandalism fire or other intervening acts not attributable to Braun damage resulting from tire wear or tire failure defacing scratches dents or chips on any interior or exterior surface of the product including those caused by rocks or other road hazards damage caused by off road use overloading or alteration of the product or any of its components or parts Defects and or damage to interior and exterior surfaces and other appearance items may occur at the fac tory or when the product is in transit These items are usually detected and corrected at the factory or by a dealer prior to delivery to the purchaser You must inspect the product for this type of damage when you take delivery If you find any such d
13. within 20 days after the lift is put into service the warranty labor coverage will increase from one 1 year or 3 000 cycles to three 3 years or 10 000 cycles In addition providing the warranty registration card is returned as noted above the following lift s power train parts are warrantied for five 5 years or 15 000 cycles Cable Cylinder Flow Control Gear Box Mo tor Pump Hydraulic Hose and Fittings This limited warranty covers substantial defects in materials and workmanship of the lift provided that the lift is operated and maintained properly and in conformity with the owner s manual The warranty period begins on the date that the product is delivered to the first retail purchaser by an independent authorized dealer of Braun or if the dealer places the product into any type of service prior to retail sale on the date the dealer first places the product in such service This limited warranty applies only to the first purchaser It may not be transferred WHAT BRAUN WILL DO TO CORRECT PROBLEMS In the event that a substantial defect in material or workmanship attributable to Braun is found to exist during the first year of warranty coverage it will be repaired or replaced at Braun s option without charge for parts or labor to the owner in accordance with the terms conditions and limitations of this limited war ranty If the substantial defect in material or workmanship attributable to Braun is found to exist during t
14. 13 Platform folding Ill pressure 14 Timed told cinching lt to or state 18 Platform folding stopped 16 Paused fold 17 Platform between ground and 3 above ground 18 Plallorm above 2 19 Outer barrier moving to horizontal postion 20 Tho doors aro not uly opened only applicable when door operators are installed 21 The doors are opening only applicable when door operators are installed 22 The doors are closing only applicable when door operators aro installed 28 function not defined 29 Interlock fault not recognized or has been cleared bul a mation button i sil prossod Platform location unknown 31 Platform location transition state attempting to locato position 35 Two or more motion buttons are being pressed 26 The retention belt cannot be buckled while trying to fold or untold 37 Motion button being pressed isnot a valid mation 50 Outer barrier is not up above inboard barter lacked position 51 Threshold is occupied when platlorm is 1 or mote below floor level 52 Inner rolstop is not up and locked below inner rolsop locked position 53 Inner rolstop occupied sensor is not activated between loor and inner rollstop position 54 Outer barrier is occupied before Lis up 55 Outer barrier is not latched when above the inner ralistop locked position Millnnium only 50 Outer barrier is not up and latched and bridge switch did not deactivate
15. Hand Pump Manual Operating Instructions To Store Pump Handle To Install Pump Cover 1 Insert bottom of handle behind 1 Position cover over module 3 Insert wing stud and rotate 1 4 bottom clip See page 33 back cover and red warning turn to lock cover See Photo 2 Rotate top clip to secure lock light See Photo F H handle 2 Align outside cover lip with bottom cover offset and insert outside cover See Photo G Position cover over red light Align and insert bottom of cover OPERATION Unlock x CS Page 37 Decals and Antiskid AWARNING Decals 30695 The lift is only as safe as 33221 29052 the operator Replace any missing worn or illegible decals Part numbers are provided for decals In spect your lift for missing worn or illegible decals Replace missing worn or illegible decals Failure to do so may result in serious bodily injury and or property 31412 MANUAL OPERATION LIFT OPERATING INSTRUCTIONS f TO REMOVE PUMP HANDLE Call 1 800 THE LIFT for erie pan ii OPEN DOORS AND SECURE Using hand pump handle TO UNFOLD PLATFORM replacements TO UNFOLD PLATFORM OUT 1 Close hand pump valve Note Clean surfaces as detailed on page 40 before posting decals 31045 OPERATING INSTRUCTIONS 25675
16. Inspect gas springs cylinders for wear or damage proper operation and positive securement Inspect rotating pivot slide arm UHMW slide bear ings buttons Tighten repair or replace if needed Replace if needed Tighten or replace if needed Replace damaged parts and resecure as needed Apply Light Grease during reassembly proce dures Replace if needed Tighten replace or correct as needed Apply Door Ease or replace if needed See Lubri cation Diagram Consecutive 750 Cycle Intervals Maintenance and Lubrication Schedule Inspect vertical arm plastic covers Inspect power cable Mounting Decals and Antiskid Repeat all previously listed inspection lubrica tion and maintenance procedures at 750 cycle intervals Resecure or replace if needed Resecure repair or replace if needed Check to see that the lift is securely anchored to the vehicle and there are no loose bolts broken welds or stress fractures Replace decals if worn missing or illegible Re place antiskid if worn or missing See Decals and Antiskid section on pages 38 40 Page 49 Limited Warranty WARRANTY COVERAGE AND WARRANTY COVERAGE TIME PERIODS The Braun Corporation Braun warranty covers certain parts of this wheelchair lift for three 3 years or 10 000 cycles and the cost of labor to repair or replace those parts for one 1 year or 3 000 cycles If The Braun Corporation receives the warranty registration card
17. Instructions decal 30695 provides lift operating instruc tions Replace any missing worn or illegible decals If your lift does not function as intended a visual or audible warning signal is activated review the NHTSA Opera tions Checklist on page 32 Follow the Manual Operating Instructions on pages 33 37 to manually operate lift Page 27 Lift Operating Instructions Open Door s and Secure To Unfold Platform Stand clear and press the UN FOLD switch until the platform gt stops reaches floor level unfolds fully Release switch Note In event platform does not unfold press FOLD switch to re lease Lift Tite latches To Unload Passenger 1 Read Note below Load passenger onto platform and lock wheelchair brakes Note Passenger must be posi tioned fully inside yellow bound aries outer barrier must be UP and outer barrier latch must be engaged Page 28 Lift Operating Instructions To Unload Passenger continued 2 Press DOWN switch until the en tire platform reaches ground level see Photo B and the outer bar rier unfolds fully ramp position See Photo C Release switch 3 Unlock wheelchair brakes and unload passenger from platform Note Outer barrier must be fully unfolded ramp position until the entire wheelchair or standee has crossed the outer barrier See Photos E and F on page 30 al
18. ON Ralph W Braun Chief Executive Officer Contents Warranty Registration Instructions 2 3 Lift Terminology Lift Terminology Illustration 4 5 Direction 5 Lift Components sesser 6 7 Vehicle and Lift Interlocks 7 Lift Actions and Functions 8 Lift Operation Safety Safety Symbols e rarement 9 Lift Operation Safety Precautions 10 13 Operation Notes and Details Introduction Lift Access Doors and Interlocks 14 General Safety 2 rn ne erint 15 Control 15 Lift Features Lift Tite Latches M 16 17 Inner Roll Stop sss 18 19 Outer Barrier re me ene 19 20 Outer Barrier Latch 20 21 Outer Barrier and Latch Operation 21 21 c 21 Lift Passengers Passenger Orientation Boarding Direction 22 DIANASSS 22 Yellow Boundaries 22 23 Vehicle Floor Level Loading and Unloadirig 2 ires 23 24 Wheelchair Equipped Occupant Seat Belts 25 Operation Procedure Rev
19. Operator s Manual for NL Series Public Use Wheelchair Lifts DOT Public Use Lift DOT Public Use Lift verifies that this platform lift meets the public use lift requirements of FMVSS No 403 This lift may be installed on all vehicles appropriate for the size and weight of the lift but must be installed on buses school buses and multi purpose passenger vehicles other than motor homes with a gross vehicle weight rating GVWR that exceeds 4 536 kg 10 000 Ib Read ual CORPORATION may result in m Providing Access to the World serious bodily 1 i IC Hdqrs PO Box 310 Wi IN 46996 USA Tal BOOTHE LIFT 574 946 6153 FAX 574 946 4670 injury and or property damage Keep manual in lift storage pouch S IN uneg saa 30651 Rev H December 2009 Congratulations We at The Braun Corporation wish to express our fullest appreciation on your new purchase With you in mind our skilled craftsmen have de signed and assembled the finest lift available This manual includes safety precautions lift operating instructions manual operating instructions and instructions for maintenance and lubrica tion procedures Your lift is built for dependability and will bring you years of pleasure and independence as long as maintenance is performed regularly and the lift is operated by an instructed person Sincerely THE BRAUN CORPORATI
20. before loading or unloading a pas senger at ground level AWARNING Outer barrier must be fully unfolded ramp position until front and rear wheelchair wheels cross the barrier when loading or unloading at ground level Page 12 AWARNING AWARNING AWARNING AWARNING AWARNING AWARNING AWARNING AWARNING AWARNING Lift Operation Safety Accidental activation of control switch es may cause unintended operation s Maintenance and lubrication procedures must be performed as specified in this manual by authorized certified service personnel Replace missing worn or illegible decals Keep owner s operator s manual in lift mounted manual storage pouch at all times Never modify alter a Braun Corporation lift Do not use accessory devices not authorized by The Braun Corporation Do not remove any guards or covers Keep clear of any hydraulic leak Failure to follow these safety precautions may result in serious bodily injury and or prop erty damage Page 13 AWARNING Read become familiar with all lift operation safety precautions opera tion notes and details operating instructions and manual operat ing instructions prior to operating the lift If this information is not fully understood contact The Braun Corporation immedi ately Failure to do so may result in serious bodily injury and or property damage Page 14 NL Series Public Use lift models are specifically desig
21. e photos Precautions Turn wing 1 4 turn Rotate top clip to access handle Pump Cover Hand Pump Handle MANUAL OPERATION access Page 33 Manual Operating Instructions Remove the pump cover to gain To remove the pump cover turn The pump handle is inside this access to the pump handle and the wing nut located on top 1 4 cover secured by two clips the hand pump See photos on turn and lift the pump cover off Rotate the top clip to remove the page 33 pump handle Hand Pump Release Valve 2 gt XN 1 16 intervals NS maximum Valve Tightening 30 inch Ibs Specification minimum Once valve seats 15 inch Ibs stops tighten 15 to 30 inch pounds as shown 0 XXX seats stops OOOO YOY 04 OOOO OLA OKAY YY YY 0 X QU 4 EN Note Close backup pump release valve securely before operating electric pump Release Valve Page 34 Manual Operating Instructions Remove pump cover to access hand pump and pump handle as outlined on page 33 Refer to release valve photos and illustra tion on page 34 Close Up Stop To Unfold Platform Out Down To Lower Using hand pump handle Photo B 1 Close hand pump valve place slotted end o
22. ealer or other person beyond what is expressly stated in this limited warranty Any selling or servicing dealer is not Braun s agent but an independent entity BRAUN SHALL NOT BE LIABLE FOR ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES THAT MAY RESULT FROM BREACH OF THIS LIMITED WARRANTY OR ANY IMPLIED WARRANTY THIS EXCLUSION OF CONSEQUENTIAL AND INCIDENTAL DAMAGES SHALL BE INDEPENDENT OF ANY FAILURE OF THE ESSENTIAL PURPOSE OF ANY WARRANTY AND THIS EXCLUSION SHALL SUR VIVE ANY DETERMINATION THAT THIS LIMITED WARRANTY OR ANY IMPLIED WARRANTY HAS FAILED OF ITS ESSENTIAL PURPOSE This warranty does not cover and in no event shall Braun be liable for towing charges travel lodging or any other expense incurred due to the loss of use of the product or other reason Page 52 Limited Warranty Some states do not allow limitations on how long an implied warranty lasts or the exclusion or limitation of incidental or consequential damages so the above limitations or exclusions may not apply to you HOW TO GET SERVICE To obtain warranty service the owner must do all of the following 1 Notify an authorized service center of the claimed defect attributable to Braun within the warranty cover age period designated above 2 Provide the notification mentioned in 1 above within ten 10 days of when the owner discovered or should have discovered the claimed defect 3 Promptly schedule an appointment with and take the product to an authorized s
23. ed on the opposite pump side Cylinder Code Sample Warranty Registration Card Serial No Series No Identification Tag vertical arm A second I D tag is located on the opposite pump side tower Both I D tags provide the product identification information ap pearing on the Warranty Registration card Record the information in the space provided on the next page This information must be provided when filing a warranty claim or or dering parts The Braun Corporation 1 800 THE LIFT BRAUNLIFT COM DOT Public Use Lift MODEL NL9171B Max Lifting Capacity 800 Ibs SERIAL NUMBER 01 00025 PUMP CODE CYLINDER 56 14cG MFG DATE 10 24 04 C e5 72 245 95 54 0110 00 Sample PATENT Warranty and Registration Instructions Model No Pump Code Note This information must be provided when filing a war Series No Cylinder Code ranty claim or ordering parts Keep for future use Serial No Date of Manufacture Page 3 Visual Lift Tite Latches 2 Top Parallel A 2 4 Threshold atches 2 op ara el Arms 2 Warning Towers 2 Main Cylinders 2 La Audible Unfold Assist Compression Springs 2 f Threshold Adjustable Quiet Ride Stow Blocks 2 lt 2 Warning e oS SSS T Opposite Pump Side Vertical Arm e 3 Vertical Arm Covers 4 Hand Held Pendant e Handrails 2 Contro
24. efect or damage you must notify the selling dealer or Braun at the time Page 54 Limited Warranty of delivery to have these items covered by this limited warranty and to have work performed on the items at no cost to you as provided by this limited warranty EVENTS DISCHARGING BRAUN FROM OBLIGATION UNDER WARRANTY The following shall completely discharge Braun from any express or implied warranty obligation to repair or replace anything and void this warranty misuse neglect collision accidents failure to provide routine maintenance See Owner s Manual unauthorized alteration off road use Acts of Nature damage from weather or the environment theft vandalism tampering fire explosions overloading the product and odometer tampering LEGAL REMEDIES Any action to enforce any portion of this limited warranty or any implied warranty must be commenced within six 6 months after expiration of the warranty coverage period designated above or the action will be barred because of the passage of time Any performance of repairs shall not suspend this limitation period from expiring Any performance of repairs after the warranty coverage period has expired or performance of repairs regarding any thing excluded from coverage under this limited warranty shall be considered good will repairs and they will not alter the terms of this limited warranty or extend the warranty coverage period or the filing limitation period in this paragra
25. enance procedures to be performed more often than specified Maintenance Indicator The Lift Ready green LED mounted on top of the pump cover will begin to blink after every 750 cycles The blinking LED will not affect the functions of the lift but is a reminder to complete necessary maintenance and lubrication Once the lift has been serviced fully stow the lift Once stowed press the UP button on the hand pendant and the Floor Level Set but ton on the back side of the pump cover until the Lift Ready green LED stops blinking Discontinue lift use immediately if maintenance and lubrication procedures are not properly per formed or if there is any sign of wear damage or improper operation Contact your sales represen tative or call The Braun Corporation at 1 800 THE LIFT One of our national Product Support repre sentatives will direct you to an authorized service technician who will inspect your lift See the Maintenance Lubrication Schedule for recommended applications per number of cycles Specified recommended Lubricant WET Ele G Braun Lubricant Amount Part No Light Penetrating Oil LPS2 General Purpose 16 oz 15807 LO Light Oil 30 weight or equivalent Penetrating Oil Aerosol Can Stainless Stick Door Ease 1 68 oz 15806 DE Door Ease Style tube Stick tube Light Grease Lubriplate 14 oz 15805 LG Light Grease Multipurpose Can Page 42 Lift Tite Latches Tower Pivot Points
26. er barrier will not raise if occupied Ll Verify platform lighting when lift is deployed and pendant illumination when lift is powered 1 A visual and audible warning will activate if the threshold area is occupied when the platform is at least one inch below floor level Page 32 Platform move ment is prohibited beyond the position where the inner roll stop is fully de ployed up AWARNING Discontinue lift use immediately if any lift vehicle interlock does not operate properly Failure to do so may result in serious bodily injury and or property Platform movement shall be interrupted unless the outer barrier is deployed up Public use vehicle manufacturers are responsible for complying with the lift lighting requirements in Federal Motor Vehicle Safety Standard No 404 Platform Lift Installations in Motor Vehicles 49 CFR 571 404 Manual Operating Instructions Instructions and photos are operating instructions also Left side pump applications are provided for all steps that Note Inner roll stop and outer a mirrored image Refer to the differ from standard lift opera barrier automatically function Lift Operating Instructions for all tion procedures The Manual during manual operations normal lift operation procedures Operation decal posted inside Note A right side pump lift Follow all Lift Operation Safety pump cover provides manual model is depicted in th
27. ervice center for service 4 Pay any transportation costs and all expenses associated with obtaining warranty service Since Braun does not control the scheduling of service work at the independent dealerships you may en counter some delay in scheduling or completion of work If you need assistance you may contact Braun at 631 West 11th Street Winamac Indiana 46996 1 800 THE LIFT 843 5438 If two 2 or more service attempts have been made to correct any covered defect that you believe impairs the value use or safety of the product or if it has taken longer than thirty 30 days for repairs to be com pleted you must to the extent permitted by law notify Braun directly in writing at the above address of the unsuccessful repair s of the alleged defect s so that Braun can become directly involved in providing service pursuant to the terms of this limited warranty Page 53 Limited Warranty WHAT IS NOT COVERED This Limited Warranty does not cover any of the following defects in materials components or parts of the product not attributable to Braun any material component or part of the product that is warranted by another entity Note the written warranty provided by the manufacturer of the material component or part is the direct responsibility of that manufacturer items that are added or changed after the product leaves Braun s possession additional items installed at any dealership or other place of business or by any
28. f pump handle onto backup pump release valve and turn clockwise N Insert handle in pump and stroke until platform folds fully stops 3 Open hand pump valve turn counterclockwise until platform reaches floor level Open 1 2 turn only 4 Close hand pump valve turn clockwise Note Valve must be tight but do not overtighten Place slotted end of pump handle onto backup pump release valve and turn counterclockwise open 1 2 turn only until the platform reaches ground level and roll stop unfolds Stroking Hand Pump Page 35 Manual Operating Instructions Remove pump cover to access hand pump and pump handle as outlined on page 33 Refer to release valve photos and illustra tion on page 34 Close Up Stop Page 36 Up To Raise Using hand pump handle 1 Place slotted end of pump han dle onto backup pump release valve and turn clockwise to close securely See Photo D Note Valve must be tight but do not overtighten 2 Insert handle into backup pump and stroke until platform reaches floor level see Photo E To Fold Platform In Insert handle into backup pump and stroke until platform stops folds fully See Photo E Note Close backup pump release valve securely before operating electric pump Store pump handle and install pump cover as outlined on page 37 Stroking
29. for any reason contact with an obstruction me chanical failure exceeding the lift floor to ground capacity etc After the platform is fully low ered the attendant should continue to press the DOWN switch to unfold the outer barrier fully ramp position Note The barrier must be fully unfolded until the entire wheelchair or standee has crossed the barrier when loading or unloading at ground level Discontinue lift op eration immediately if the outer barrier or latch do not operate properly Bridging The NL incorpo rates a bridging feature This feature stops the down travel of the platform if the outboard end of the platform contacts a raised surface such as a curb preventing the operator from lowering the inboard end of the platform Handrails Dual handrails are provided for wheelchair pas senger or standee use The handrails unfold automatically to the deployed horizontal position when the lift unfolds and automatically fold to the stowed vertical position when the platform folds If able passengers should grip both handrails when on the lift platform Discontinue lift opera tion immediately if the handrails do not operate properly Page 21 Operation Notes and Details Lift Passengers If you are an attendant operating the lift it is your responsibility to perform safe loading and unload ing procedures Wheelchair lift attendants should be instructed on any special
30. g 79 Threshold tape switch B is Flashing 80 Postion sat button is pressed Flashing 81 Single function UP FOLD CLOSE button pressed Flashing 82 Single function OPEN UNFOLD DOWN bution is pressed Flashing 87 CLOSE bution is pre Flashing 88 OPEN button Flashing 89 Door full open or jumpor is installed or board 34267 BRAUN MILLENN 31132 PLATFORM RELIEF VALVE ADJUSTMENT Platform Fold Relief Valve See service manual for adjustment procedure UM SERIES 32845 Rotate to floor before operating lift 30787 27154 Improper handling and or servicing procedures may result in electrostatic discharge ESD ESD may result in electronic module damage Improper hydraulic pressure switch adjustment may result in serious bodily injury and or property damage HYDRAULIC PRESSURE SWITCH ADJUSTMENT Adjust switch as specified in installation service manual Page 39 Decals and Antiskid Decals 22249 Contact The Braun y Veer ODN 29051 Corporation before E i adjusting hydraulic MANUAL 1 Wide Yellow Boundary Tape 18229 OPERATION 30236R pressure relief valve Failure to MADE IN Tum wing oc order by the inch as needed AMERICA do so may result hand pump Quality inspected access at M in serious bodily injury a
31. gram Apply Light Oil See Lubrication Diagram Resecure replace damaged parts or otherwise correct as needed Note Apply Light Grease to Lift Tite latch tower pivot point if replacing latch Correct or replace damaged parts Correct or replace damaged parts and or relubri cate See Lubrication Diagram See applicable service manual See NHTSA Operations Checklist Maintenance and Lubrication Schedule Inspect lift for wear damage or any abnormal Correct as needed condition Inspect lift for rattles Correct as needed Perform all procedures listed in previous section also Platform pivot pin bearings 2 Platform fold axles 2 Inner roll stop lever bearings 2 Inner roll stop lever slot 2 Rotating pivot slide arm pivot pins 2 Parallel arm pivot bearings 16 Handrail pivot pin bearings 4 Hydraulic cylinder bushings 8 Inspect Lift Tite latch rollers for wear or damage positive securement and proper operation 2 Apply Light Oil See Lubrication Diagram Apply Light Oil See Lubrication Diagram Apply Light Oil See Lubrication Diagram Apply Light Oil See Lubrication Diagram Apply Light Oil See Lubrication Diagram Apply Light Oil See Lubrication Diagram Apply Light Oil See Lubrication Diagram Apply Light Oil See Lubrication Diagram Correct replace damaged parts and or relubri cate Page 45 Maintenance and Lubrication Schedule Perform all procedures listed in
32. he second or third year of warranty coverage it will be repaired or replaced at Braun s option without charge to the owner for parts only in accordance with the terms conditions and limitations of this limited warranty Page 50 Limited Warranty Providing the warranty card is returned within 20 days as outlined above the labor warranty period will be extended by two years of coverage in accordance with the terms conditions and limitations of this limited warranty In addition if a substantial defect in material or workmanship attributable to Braun is found to ex ist during the fourth or fifth year of warranty coverage to the following lift s power train parts Cable Cylinder Flow Control Gear Box Motor Pump Hydraulic Hose and Fittings it will be repaired or replaced at Braun s option without charge to the owner for parts only in accordance with the terms conditions and limitations of this limited warranty The cost of labor for repair or replacement at any time after the warranty coverage detailed above is the sole responsibility of the owner Braun s obligation to repair or replace defective materials or workmanship is the sole obligation of Braun under this limited warranty Braun reserves the right to use new or remanufactured parts of similar quality to complete any work and to make parts and design changes from time to time without notice to anyone Braun reserves the right to make changes in the design or materia
33. iew 25 26 Preventive Maintenance _ 26 Lift Operating Instructions 27 31 NHTSA Operations Checklist 32 Manual Operating Instructions 33 37 Decals and Antiskid 38 40 Maintenance and Lubrication 41 49 Limited Warranty 50 57 Warranty and Registration Instructions Immediately upon receiving your lift examine the unit for any dam age Notify the carrier at once with any claims Two warranty registration cards shown below are located in the pump cover owner s manual storage pouch The sales repre sentative must process one of the cards The consumer must fill out Series No Model No Pump Code Serial No OWNER WARRAI TY REGI TRATION NL9171B 04 02730 56 14CG OWNER ADDRESS city TELEPHONE STATE ziP VALIDATE WARRANTY TO REGISTRATION CARDS MUST BE RETURNED TO THE BRAUN CORPORATION Page 2 the other card and mail it to The Braun Corporation The warranty is provided on the back cover of this manual The warranty cards must be processed to activate the warranty Two Braun Serial No Series No identification tags are posted on the lift One I D tag shown below is post
34. l Threshold d Q Warning Pump Module Lift Terminology Base Illustration Plate Bottom Parallel Inner Roll Stop Arms 2 Inboard Right rod Platform Pivot Arms 2 SS m Left Outboard Rotating Pivot Slide Arms 2 Pump Side Vertical Arm Outer Barrier Cylinder f not visible underside of platform Platform Side Plates 2 Outer Barrier Latch d Outer Barrier Automatic Outboard Roll Stop Page 4 Introduction Braun NL Millennium Series lifts are ADA compliant and comply fully with National Highway Traffic Safety Adminis tration NHTSA specifications The NL is commercial oriented intended for operation by an attendant Lift models vary per size lift model numbers indicate lift dimensions NL Series lift models can be equipped with left or right side pump modules as needed A left side pump equipped lift model is depicted in the Lift Terminology Illustra tion NL9171B Right side pump lift models are a mirrored image of rear pump models Lift Terminology pump module located on op posite end of base plate Refer to the Lift Terminology Illustration for identification of lift components Lift operation procedures are identical for all NL Series lift models The operating instructions contained in this manual and appearing on lift posted operating instructions decals address the lift control Switches and the correspond ing lift functions Instruc tions are provided for
35. l of its products without incurring any obligation to incorporate such changes in any previously manufactured product Braun makes no warranty as to the future performance of this product and this limited warranty is not intended to extend to the future performance of the product In addition the owner s obligation to notify Braun or one of its authorized inde pendent dealers of a claimed defect does not modify any obligation placed on the owner to contact Braun directly when attempting to pursue remedies under state or federal law Page 51 Limited Warranty LIMITATIONS EXCLUSIONS AND DISCLAIMER OF IMPLIED WARRANTIES ANY IMPLIED WARRANTY THAT IS FOUND TO ARISE BY WAY OF STATE OR FEDERAL LAW IN CLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY OR ANY IMPLIED WARRANTY OF FITNESS IS LIMITED IN DURATION TO THE TERMS OF THIS LIMITED WARRANTY AND IS LIMITED IN SCOPE OF COVERAGE TO THE SCOPE OF COVERAGE OF THIS LIMITED WARRANTY Braun disclaims any express or implied warranty including any implied warranty of fitness or merchantability on items excluded from coverage as set forth in this limited warranty Braun makes no warranty of any nature beyond that contained in this limited warranty No one has authority to enlarge amend or modify this limited warranty and Braun does not authorize anyone to create any other obligation for it regarding this product Braun is not responsible for any representation promise or warranty made by any independent d
36. late a minimum 1 2 When the FOLD switch is pressed and the platform folds from floor level to the stow verti cal position the roll stop auto matically travels inboard to the stowed position Interlock Features The inner roll stop features a locking mechanism that prohibits the plat form from lowering if the lock is not engaged The inner roll stop also senses weight to prohibit lift operation The lift will not function if inner roll stop is occupied Discontinue lift operation immedi ately if the inner roll stop does not operate properly Outer Barrier This cylinder pow ered barrier provides a ramp for wheelchair loading and unloading at ground level see photos on following page When the plat form lowers fully to ground level the cylinder compression spring automatically unfolds rotates the barrier to the ramp position fully unfolded Although the outer barrier is lift powered the activation of the barrier is controlled by the lift operator attendant Press ing the DOWN switch unfolds the barrier The outer barrier is cylinder powered to automati cally fold rotate to the vertical position as shown when the UP switch is pressed barrier raises before platform raises Interlock The outer barrier senses weight to prohibit lift op eration The lift will not function if the outer barrier is occupied Page 19 Operation Notes and Details Lift Features continued
37. ll procedures listed in previous sections also Inspect cotter pins on platform pivot pin 2 Hydraulic Fluid Pump Check level Note Fluid should be changed if there is visible contamination Inspect the hydraulic system cylinder hoses fit tings seals etc for leaks if fluid level is low Inspect cylinders fittings and hydraulic connections for wear damage or leaks Resecure replace or correct as needed Use Braun 32840 QT hydraulic fluid Exxon Uni vis HVI 26 Do not mix with Dextron III or other hydraulic fluids Check fluid level with platform lowered fully Fill to maximum fluid level indicated on reservoir specified on decal Do not overfill If fluid level decal is not present measure 1 3 8 from the fill port to locate fluid level Tighten repair or replace if needed Page 47 Page 48 Maintenance and Lubrication Schedule Perform all procedures listed in previous section also Inspect outer barrier cylinder hose assembly hose fasteners connections etc for wear damage or leakage if equipped Inspect parallel arms bushings and pivot pins for visible wear or damage Inspect parallel arm pivot pin mounting bolts 8 Inspect platform pivot pin bushings and vertical arms for wear damage and positive securement Inspect upper lower fold arms rotating pivot slide arms slide support arms and associated pivot pins bushings and bearings for visible wear or damage
38. mended intervals inspection and lubrication procedures specified in the previous sections should be re peated Clean components and the surrounding area before applying lubricants LPS2 General Purpose Penetrating Oil is recommended where Light Oil is called out Use of im proper lubricants can attract dirt or other contaminants which could result in wear or damage to the com ponents Platform components exposed to contaminants when lowered to the ground may require extra attention AWARNING Maintenance lubrication proce dures must be per formed as specified by an authorized service technician Failure to do so may result in serious bodily injury and or property damage Lift components requiring grease are lubricated during assembly procedures When these compo nents are replaced grease must be applied during installation procedures Specified lubricants are available from The Braun Corporation part num bers provided on page 42 Page 41 Maintenance and Lubrication All listed inspection lubrication and maintenance procedures should be repeated at 750 cycle inter vals following the scheduled 4500 cycle mainte nance procedures These intervals are a general guideline for scheduling maintenance procedures and will vary according to lift use and conditions Lifts exposed to severe conditions weather envi ronment contamination heavy usage etc may require inspection and maint
39. n pages 18 and 19 Lift Terminology Vehicle and Lift Interlocks Braun Corporation NL9171IB Series lifts comply fully with all NHTSA vehicle and lift interlock specifications Vehicle move ment is prohibited unless the lift is fully stowed and the lift will not function unless the vehicle is parked and secured The NL features a visual and audible threshold warning system that will activate if the threshold area is occupied when the platform is one inch or more below floor level The inner roll stop and outer barrier sense weight to prohibit lift operation The lift will not function if the inner roll stop or the outer barrier are occupied The lift platform cannot be folded stowed if occupied The inner roll stop features a locking mechanism that prohib its the platform from lowering if the lock does not engage The lift platform cannot be raised more than 3 above ground level unless the outer barrier is in the vertical position and the outer barrier latch is positively engaged Page 7 Lift Actions and Functions DEPLOY A C A UNFOLD Out Platform Unfold Unfold is the action of the platform rotating out and down from the fully stowed vertical position to floor level horizontal position when the UNFOLD switch is pressed B DOWN Platform Lower Down is the action of the platform lowering from floor level position to fully lowered ground level position when the DOWN switch is p
40. n the parallel arms The electrical hydraulic powered lift frame components mechani cally unfold lower raise and fold the lift platform assembly Platform Assembly The plat form assembly consists of the steel tubing frame with grating surface upon which the wheel chair is positioned the outer barrier outer barrier latch the inner roll stop and the hydraulic cylinder assembly that powers the outer barrier Lift Tite Latches The spring loaded latches prevent the platform from unfolding from the Stowed position in the event of platform drift Further details regarding Lift Tite latches are provided on pages 16 and 17 Outer Barrier The cylinder powered automatic outer barrier provides a ramp for wheelchair loading and unloading at ground level Photos and further details regarding the outer barrier are provided in the Operation Notes section pages 19 21 Outer Barrier Latch The spring loaded latch locks the outer bar rier in the vertical position when the platform raises above ground level Inner Roll Stop NL Series lift models are equipped with an automatic inboard roll stop that also serves as the bridge plate The roll stop bridges the gap between the lift platform and the vehicle floor The inner roll stop automatically rotates from the horizontal position to the verti cal position as the lift lowers and raises Further details regard ing the automatic mechanical inboard roll stop are provided o
41. nd or property damage ADA Cc unmanos id Available Antiskid Inspect your lift for any miss A WARNING Size Color Part No ing or worn antiskid Order 2 x12 Black 24172 BK as needed Note Clean surfaces with isopropyl alco Replace missing or worn antiskid hol before decal or antiskid 2 x 12 Yellow 24172 YL Failure to do so may 3 x 8 Black 31188 BK application Use a clean result in serious 3 x 12 Black 24173 BK cloth or paper towels Do bodily injury and or 3 x 12 Yellow 24173 YL not use oily shop rags Wipe property damage 6 12 Black 24174 BK surface free of residue with 6 x 12 Yellow 24174 YL dry portion of cleaning cloth Page 40 Maintenance and Lubrication Proper maintenance is necessary to ensure safe troublefree operation Inspecting the lift for any wear damage or other abnormal condi tions should be a part of the transit agency daily service program Simple inspections can detect potential problems The maintenance and lubrication procedures specified in the following schedule must be per formed by a Braun authorized service represen tative at the scheduled intervals according to the number of cycles NL Series lifts are equipped with hardened pins and self lubricating bushings to decrease wear provide smooth operation and extend the ser vice life of the lift When servicing the lift at the recom
42. nd or property damage Operation Notes and Details Wheelchair Equipped Occupant Seat Belts The Braun Corporation recom mends wheelchair passengers position and buckle their wheel AWARNING Position and secure buckle engage fasten etc the wheelchair equipped occupant seat belt before loading onto the wheelchair lift platform Failure to do so may result in serious bodily injury and or property chair equipped seat belt torso restraint before loading onto a wheelchair lift Different types of disabilities require different types of wheel chairs and different types of wheelchair equipped occupant restraint belt systems torso restraints It is the responsibil ity of the wheelchair passenger to have his or her wheelchair equipped with an occupant restraint seat belt under the direction of their health care professional Wheelchair lift attendants should be instructed on any special needs and or procedures required for safe transport of wheelchair passengers Operation Procedure Review The Braun Corporation rec ommends that transit agency supervisors and wheelchair lift attendants review the safety precautions and operation procedures appearing in this manual and on lift posted decals with your wheelchair lift sales representative dealer before attempting lift operation Any questions or concerns can be addressed by the sale
43. ned to be operated by an attendant The Lift Operating Instructions contained in this manual and posted on the lift provide instructions for op eration of the lift only Read and become familiar with all lift opera tion safety precautions opera tion notes and details operating instructions and manual operating instructions before attempting lift operation procedures Lift Access Doors and Inter locks Attendants must become familiar with the vehicle lift access door system and vehicle interlock system s Transit vehicles and lift access door configurations vary Door securement devices latches hooks cables etc and procedures to operate them vary Operation Notes and Details Instructions for operation of vehicle interlocks and door securement systems are not addressed in this manual or on lift posted operating instructions decals due to the variety of proce dures required for operating them Braun Corporation NL Series lifts comply fully with all NHTSA vehicle and lift interlock specifica tions detailed on pages 7 and 32 Infringement of any lift interlock will prohibit lift operation It is the responsibility of the lift operator attendant to properly open secure and close the vehicle lift door s to activate the vehicle interlock s to load and unload the wheelchair passenger or standee on and off the lift platform and to properly activate all lift functions Operation Notes and Details General
44. needs and or pro cedures required for safe trans port of wheelchair passengers The lift operator and bystanders must keep clear of the area in which the lift operates Observe your passenger at all times dur ing lift operation Do not attempt to load or unload a passenger in a wheelchair or other apparatus that does not fit on the platform area Do not ex ceed the 800 pound load capac Page 22 ity of the lift The lift attendant should not ride on the platform with the passenger Passenger Orientation Board ing Direction Braun NL Series wheelchair lifts accommodate both inboard and outboard fac ing wheelchair passengers or standees Inboard facing of wheelchair lift passengers is not prohibited but outboard facing of passengers is recommended by The Braun Corporation Braun NL Series lifts permit both inboard and outboard facing of wheelchair and mobility aid us ers and accommodate persons using walkers crutches canes or braces or who otherwise have difficulty using steps Standees Lift Operating Instruc tions apply to wheelchair pas sengers and standees Standees should stand in the center of the platform fully inside the yellow boundaries and grip both hand rails if able when on platform Yellow Boundaries The pas senger must be positioned in the center of the platform to prevent side to side load imbalance The lift attendant operator should not ride on the platform with the passenger
45. notes and details operating instructions and manual operat ing instructions before operating the lift Note Wheelchair passengers and all transit agency personnel drivers and wheelchair lift attendants must read and become familiar with the contents of this manual and supplement s before operation Load and unload on level surface only Engage vehicle parking brake before operating lift Provide adequate clearance outside the vehicle to accom modate the lift before opening lift door s or operating lift Inspect lift before operation Do not operate lift if you suspect lift damage wear or any AWARNING Keep operator and bystanders clear of area in which the lift operates Page 10 AWARNING AWARNING AWARNING AWARNING AWARNING AWARNING AWARNING AWARNING Lift Operation Safety Whenever a wheelchair passenger or standee is on the platform the Passenger must be positioned fully inside yellow boundaries Wheelchair brakes must be locked Inner roll stop and outer barrier must be up vertical Outer barrier latch must be fully engaged Passenger should grip both handrails if able Load and unload clear of vehicular traffic Do not overload or abuse The load rating applies to both the raising and lowering func tions continuous lifting capacity is 800 Ibs Discontinue lift use immediately if any lift or vehicle interlock does not operate properly Do not operate or board the lift if you or your lift opera
46. ove provided that the repair is authorized by Braun and car ried out by an authorized service center a Braun labor schedule determines the cost allowance for repairs Braun will not honor any warranty claim for repairs or replacement of parts unless the claim is submitted with the appropriate paperwork and the work is completed by an independent factory authorized service center The appropriate paperwork can be obtained by written or phone contact with Braun at the contact information in this warranty Page 56 Limited Warranty Braun reserves the right to designate where any warranty work can be performed Braun also reserves the right to examine any defective workmanship or part prior to giving any authorization for warranty work Braun s return authorization procedure must be adhered to in order to process any warranty claims THIS WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS YOU MAY ALSO HAVE OTHER RIGHTS THAT VARY FROM STATE TO STATE Page 57 Providing Access to the World Over Dealers Operator s Manual NL Series Public Use Wheelchair Lifts Patent 5 261 779 Patent 6 599 079 Patent 7 422 408 Patent 6 065 924 Patent 6 692 217 Patent 7 444 995 Patent 6 238 169 Patent 6 739 824 Patent 7 509 187 Patent 6 464 447 Patent 7 306 422 Patent 7 530 226 Patents Pending S IN une amp 4g 5
47. ph In addition since it is reasonable to expect that the product will need some service during the warranty period this warranty does not extend to future performance It only sets forth what Braun will do and does not guarantee anything about the product for any time period Page 55 Limited Warranty Nothing in this warranty or any action of Braun or any agent of Braun shall be interpreted as an extension of any warranty period or the filing limitation period in this paragraph Some states do not allow a reduction in the statute of limitations so this reduction may not apply to you WARRANTY REGISTRATION and MISCELLANEOUS Your warranty registration records should be completed and delivered to the appropriate companies includ ing the Braun Delivery Checklist amp Warranty form That form must be returned to Braun within twenty 20 days of purchase The Braun warranty will not be registered unless this warranty registration is completed and received by Braun Failure to file this warranty registration with Braun will not affect your rights under this limited warranty as long as you can present proof of purchase but it can cause delays in obtaining the benefits of this limited warranty and it changes the start date of the warranty to the date of final assembly of the product by Braun Braun agrees to repair or replace any of its factory installed parts found to have substantial defects within the appropriate warranty period designated ab
48. previous section also Inspect inner roll stop for Resecure replace or correct as needed See Wear or damage Platform Angle Instructions and Microswitch Proper operation Roll stop should just rest on Adjustment Instructions top surface of the base plate Positive securement both ends Inspect handrail components for wear or damage Replace damaged parts and for proper operation Inspect microswitches for securement and proper Resecure replace or adjust as needed See adjustment Microswitch Adjustment Instructions Make sure lift operates smoothly Realign towers and vertical arms Lubricate or correct as needed Inspect external snap rings Resecure or replace if needed Handrail pivot pins 2 per pin Platform slide rotate pivot pins 2 per pin Platform fold axles 1 per axle Inner roll stop lever bracket pins 1 per pin Lift Tite latch gas dampening spring 2 per spring Page 46 Maintenance and Lubrication Schedule Inspect platform fold axles and bearings for wear or damage and positive securement Remove pump module cover and inspect Hydraulic hoses fittings and connections for wear or leaks Harness cables wires terminals and connec tions for securement or damage Control board circuit breaker power switch and lights for securement or damage Replace damaged parts and resecure as needed Apply Light Oil Resecure replace or correct as needed Perform a
49. pro vided for your safety Familiarity This symbol indicates This symbol indicates with proper operation instructions important safety important information as well as proper maintenance information regarding regarding how to procedures are necessary to en a potentially hazard avoid a hazardous sure safe troublefree operation ous situation that situation that could Safety precautions are provided could result in serious result in minor per to identify potentially hazardous bodily injury and or sonal injury or prop situations and provide instruction property damage erty damage on how to avoid them D Note Additional information provided to help clarify or detail a specific subject These symbols will appear throughout this manual as well as on the labels posted on your lift Recognize the seriousness of this information Page 9 Lift Operation Safety Lift Operation Safety Precautions AWARNING If the lift operating instructions manual operating instructions and or lift operation safety precautions are not fully understood contact The Braun Corporation immedi ately Failure to do so may result in serious bodily injury and or property damage AWARNING AWARNING AWARNING AWARNING AWARNING abnormal condition Read manual and supplement s before operating lift Read and become familiar with all safety precautions operation
50. ressed C DOWN Outer Barrier Unfold Deploy When the platform reaches the fully low Page 8 Lift Terminology ered ground position and the DOWN switch is continued to be pressed the outer barrier rotates downward from vertical position to ramp position STOW D F D UP Outer Barrier Fold Raise When the lift is fully lowered and the outer barrier is in the ramp position pressing the UP switch first rotates the outer barrier upward from ramp position to vertical position E UP Platform Raise Up is the action of the platform raising from ground level to floor level fully raised position when the UP switch is pressed F FOLD In Platform Fold Fold is the action of the platform rotating up and in from the floor level horizontal position to fully stowed vertical position when the FOLD switch is pressed Stowed Position The lift is stowed when the lift platform has been fully raised and folded fully vertical position Floor Level Floor level is the position height the platform as sembly reaches in order for the wheelchair passenger to enter and exit the vehicle fully raised The platform automatically stops at floor level when unfolding from the stowed position and when raising from ground level Lift Operation Safety Safety Symbols SAFETY FIRST Know That All inf i ined Alinthismenudand B AWARNING ACAUTION supplements if included is
51. s rep resentative at that time Oper ate the lift through all functions with your sales representative on hand to ensure the proper use and operation of the wheel chair lift is understood Page 25 Operation Notes and Details Transit agency supervisors should train and educate their lift attendants on the proper use and operation of the wheelchair lift if it is not possible for the attendants to review the safety precautions and operation pro cedures with the wheelchair lift sales representative The lift operator s manual must be stored in the lift mounted manual storage pouch at all times Preventive Maintenance Maintenance is necessary to ensure safe and troublefree lift operation General preventive lift maintenance consisting of careful inspections of the lift sys tem and cleaning the lift should Page 26 be a part of your transit agency s daily lift service program Simple inspections can detect potential lift operational problems Regular preventive maintenance will reduce potential lift opera tion downtime and increase the service life of the lift as well as possibly detecting potential hazards Exposure to harsh weather ele ments environmental conditions or heavy usage may require more frequent maintenance and lubrication procedures Preventive maintenance visual inspections do not take the place of the procedures specified in the Maintenance and Lubrication Schedule provided
52. so Lift Operating Instructions To Load Passenger 1 Read Notes below Load passen ger onto platform and lock wheel chair brakes See Photo G Note Outer barrier must be fully unfolded ramp position until the p gt entire wheelchair or standee has crossed the outer barrier See Photos E and F Note Passenger must be posi tioned fully inside yellow boundar ies Page 30 Lift Operating Instructions Load Passenger continued lt 2 Press UP switch Photo 1 to fold outer barrier UP fully vertical see Photo H and raise the platform to floor level See Photo J Release switch 3 Unlock wheelchair brakes and unload passenger from platform To Fold Platform lt Press FOLD switch until platform gt stops fully folded See Photos K and L Release switch Close Door s Page 31 NHTSA Operations Checklist The following operations have been verified upon installation This operational checklist can be used at any time to verify the lift is fully functional Verified 1 Vehicle movement is prevented unless the lift door is closed ensuring the lift is stowed 1 Lift operation shall be prevented unless the vehicle is stopped and vehicle movement is prevented _ The platform will not fold stow if occupied 1 The inner roll stop will not raise if occupied L The out
53. t use eke immediately if any Latch lift component does not operate prop erly Failure to do so may result in serious bodily injury and or property damage Page 16 Operation Notes and Details vent the platform from unfolding from the stowed position in the event of platform drift Due to the all hydraulic operation of the dual cylinder NL hydraulic fluid expansion contraction or seepage may occur Any of these conditions may result in platform drift failure to hold the platform in the folded or raised position Platform drift may occur during lift shipment and or between extended periods of non lift use In the event that the platform does not unfold when the UNFOLD switch is pressed press the FOLD switch mo mentarily to disengage the Lift Tite latches platform drift has occurred Then press the UNFOLD switch to unfold the platform to floor level standard operation When manually operating a lift equipped with Lift Tite latches insert the pump handle in the pump and stroke until the plat form folds fully stops Then Disengaged Lift Tite Latch Latch En gagement Pin Roller open the hand pump valve turn counterclockwise to unfold the platform Folding the platform fully first will ensure that the Lift Tite latches will disengage properly when the release valve is opened Manual Operating Instructions are provided on pages 33 37 Page 17
54. tor are intoxicated Do not raise front wheelchair wheels pull wheelie when loading boarding the platform Open lift door s fully and secure before operating lift Position and secure buckle engage fasten etc the wheelchair equipped occupant seat belt torso restraint before loading onto the wheelchair lift platform Page 11 Lift Operation Safety Lift Operation Safety Precautions continued AWARNING If the lift operating instructions manual operating instructions and or lift operation safety precautions are not fully understood contact The Braun Corporation immedi ately Failure to do so may result in serious bodily injury and or property damage AWARNING AWARNING AWARNING AWARNING AWARNING Lift attendants must ensure that lift occupants keep hands arms and all other body parts within the lift occupant area and clear of moving parts Platform must be positioned at floor level roll stop height when loading or unloading in and out of vehicle Do not use platform inner roll stop or outer barrier as a brake Stop and brake wheelchair when loading onto the platform manually stop and brake manual wheelchairs stop powered wheelchairs with the wheelchair controls Turn powered electric wheelchairs off when on lift platform Press the DOWN switch until the entire platform rests on ground level lowered fully and the outer barrier is fully unfolded ramp position