NC300 Nurse-Call System

image

Contents

1. i 0 Note To open master station requires a Scrulox size 0 screwdriver available from TekTone part number HT004 12 IL421 Tek MICRO Nurse Call System Manual Copyright TekTone Sound amp Signal Mfg Inc All Rights Reserved 3 0 SYSTEM CONFIGURATION PROGRAMMING The following information should be programmed into the NC300 System by qualified administrative personnel prior to general staff operation Information programmed at this time should require few changes 3 1 ROOM BED NUMBER AND ZONING The currently assigned station address DIP switch ASSIGNMENTS FOR IR SERIES STATIONS Assign station room bed numbers and station zone assign ments following the procedure listed below System should notbein use while room bed numbers and zone assignments are being entered Stations must be assigned to at least one of the 8 zones supported by the NC300 System but may be assigned to additional zones if desired Zoning assignments are used to send station calls to a specific master station also zoned for those call ins Stations must be assigned to the same zone as the master station to which they will report Refer to the chart provided for listing assigned room bed numbers Note On Main Menu numbers 8 and 9 used on NC350CP Series
2. enn Smoke Detector Contacts Normally Open Gra Audio ve 4 m el Purple Monitor Contact Audio Optional Method 12 VDC Data Com Data Out Data In Negative Blue for Monitor Contact Normally Open Note Use only if Yellow Emergency Input is Optional Method for Smoke Detector not used Note Use only if both Emergency 1 and Monitor Inputs are used Red a RYN Brown ENDE NOTE IR315B does not support CODE BLUE Stations 16 Gauge Ground Wire SEE NL402 FOR SPECIFICATIONS Common Cable WM300 To NC300 CPE TITLE 300 WIRING DAIGRAM DATE 12 23 98 APP 1 SERIES CONNECTIONS TO PERIPHERAL DEVICES PAGE NL411 PM321B PM322B LAMP MODULE TV AUDIO amp SWITCH COMMON REE TV AUDIO FROM TV OUTLET me TV SWITCH OUTPUT CONNECTS TO BROWN WITH BED 2 YELLOW a BUTTON DEPRESSED COMMON AUDIO 7 PIN CONNECTOR GREEN RADIO OUTPUT TO RY350 23 VIOLET NOT USED LAMP RELAY OUTPUTS ibi ROOM LA COMMON FROM PILLOW SPEAKER 2 ORANGE READ LAMP ren READ LAMP COMMON H ROOM LAMP FROM PILLOW SPEAKER 1 ORANGE 8 PIN CONNE
3. 11421 SECTION E SOUND amp 51 Rev 24 03 2002 Tek MICRO NC300 Microprocessor Nurse Call System UL Listed 1069 INSTALLATION INSTRUCTIONS AND SERVICE MANUAL Version 1 96 NC350C 64 NC350C 64P Version 3 06 NC350C128P Version 4 06 NC350CPX2 Alpha Communications 42 Central Drive Farmingdale NY 11735 1202 Phone 631 777 5500 APPLICATION Tek MICRO NC300 Microprocessor Nurse Website Call System is a computer controlled supervised system utilizing www alpha comm com central processing equipment along with patient staff and duty stations emergency stations code call stations presence stations Email dome and zone lights info alpha comm com TOLL FREE Technical The NC300 Series is designed for individual hospital ward use 1 800 666 4800 nursing homes or congregate living centers Tek MICRO NC300 Microprocessor Nurse Call System Installation Instructions and Service Manual Version 1 96 NC350C 64 NC350C 64P Version 3 06 NC350C128P Version 4 06 NC 350CPX2 Copyright TekTone amp Sound amp Signal Mfg Inc 1989 2002 The software described in this manual is furnished under a license agreement and may be used only in accordance with the terms of the agreement All rights reserved No partofthis publication may be copied withoutthe express written permission of TekTone Sound amp Signal Mfg Inc The contentofthis manual is furnished for informa
4. oun IS10N D QAYI dWV 4752 SNOLOSNNOO 14 9 OML SWOLOSNNOO CUVOd IHLOW ANN TOA ADVd OWA GI ensopus Jededys 4 OVA STT MS 33O NO J9 0d youmskey uowwsKey yesey MICRO Nurse Call System Manual 65 IL421 Tek Copyright TekTone Sound amp Signal Mfg Inc All Rights Reserved HILL ROM ADAPTER RECEPTACLE Hospital Grade TV UL1410 Hospital Grade TV UL1410 uno BD e e po e uno RY351 HILL ROM ADAPTER RECEPTACLE 0 CPE Port Cable ra TekTone TITLE RY351 WIRING DIAGRAM MATL KLM DATE 06 16 95 APP NC300 NURSE CALL SYSTEM REV 4 PAGE NL414 66 ILA21 Tek MICRO Nurse Call System Manual Copyright TekTone Sound amp Signal Mfg Inc All R
5. Fig 7 RCA jack plugs into video input located on back of monitor d 1 RG59 U coaxlal cable solid copper Fig 6 IR315B DUTY STATION LAYOUT DIP SWITCH LOCATION ON IR SERIES STATION PRINTED CIRCUIT BOARDS 8 PIN cme 15 PIN CONNECTOR DIP SWITCH IR SERIES STATION PCB gr 3 45 6 7 N pie 10000000 206 7 Use only DIP switches 1 6 for station addressing Use only DIP switches 1 3 for Masters NOTE Each DIP switch in the ON position represents a specific value The sum of all values represented by switches in the ON position form the station s address code Valid DIP switch values are 0 31 0 63 for NC350CPX2 No other numbers can be used DIP switch 7 turns IR300B and LI386 Zone Light function on and turns IR310B into a ROUTINE call station This is automatically set whenever CPE is initialized or powered up If necessary you may change the setting of DIP switch 7 by 1 deleting station setting System Programming Section 3 4 2 change DIP switch 3 add station back to system Copyright TekTone Sound amp Signal Mfg Inc All Rights Reserved DIP SWITCH VALUES SWITCH POSITION VALUE 1 1 2 2 3 4 4 8 5 16 6 32 7 64 IL421 Tek MICRO Nurse Call System Manual 11
6. DB9 FEMALE CONNECTOR NC362 VIDEO CARD SERIAL PORT SHIELD CTS SIGNAL GROUND TRANSMIT DATA SIGNAL GROUND RECEIVE DATA DSR DSR DTR NC350 CPE 11 20 97 TekTone TITLE NC362 Video amp Serial Card MATL CB 1 Wiring Diagram APP NC300 NURSE CALL SYSTEM REV 2 NL417 Copyright TekTone Sound amp Signal Mfg Inc All Rights Reserved IL421 Tek MICROS Nurse Call System Manual 69 SOUND amp SIGNAL NC300 Microprocessor Nurse Call System Supplement to Manual 11421 11421 Tek MICRO Manual Supplement 1 0 2 0 3 0 4 0 Tek MICRO NC300 Microprocessor Nurse Call System Supplement to Installation Instruction and Service Manual IL421 Version 1 95 NC350C 64 NC350C 64P Version 3 05 NC350C128P Version 4 05 NC350CPX2 TABLE OF CONTENTS SOFTWARE ENHANCEMENTS ccccssssssssssssssscsssssssssssssscsssssssssssssessssessssessesessssessesessesessesessesesesesseoess 51 ROOM LABELS S1 2 1 CHOOSE A STANDARD LABEL 2 2 CHANGE A STANDARD LABEL 2 3 ASSIGNING ROOM NUMBERS AND LABELS HELP SCREENG ccsssssssssssosessosessosesscsesscsesscsesscsessesssscsessessssesessessssessssassssassssessssessssecesessesessesessesessesess 53 FIGURE 13 ANSWER CALL MENU FIGURE 14 PLACE A CALL MENU FIGURE 15 REQUEST SERVICE MENU FIGURE 16 NURSE FOLLOWER MENU FIGURE 17 PAGE A ZONE MENU FIGURE 18 ROOM PROGRAM PRI
7. enter time and date D Enter time and new date Press to save 3 13 SET CALL OVERTIME The elapsed time from when a call is placed to the master station and the call overtime indication OT appears may be set following the procedure listed Call overtime may be programmed for ROUTINE PRIORITY and SERVICE requests If the call overtime is exceeded on a service request a call will be placed to the associated patient station from the master station Service request overtime calls must be canceled from the patient station or a nurse or aide must register their presence in the room if it is equipped with a SF350B nurse aide button and then register out again whenleaving roomon patient station Follow the procedure listed to set call overtime Note On Main Menu numbers 8 and 09 used on NC350CP Series 8 and 9 not present on NC350C 64 A Press MENU blue button MAIN MENU 1 Help Menu 2 Master Assignments Menu 3 User Function Menu 4 System Function Menu 5 6 7 Set Room Privacy Page Room Monitoring Radio Pager Menu exit select menu item IL421 Tek MICRO Nurse Call System Manual 17 Select System Function Menu by pressing 4 on keypad SYSTEM FUNCTIONS Set Time Date 12 24 Hour Clock Set Overtime Reconfiguration Hook Switch prev menu select menu item Select Set Overtime by pr
8. Copyright TekTone Sound amp Signal Mfg Inc All Rights Reserved D Select Reinitialize System by pressing 2 on key pad If reinitialization is desired press 1 on keypad to continue or to return to menu CAUTION Reinitialization will erase all data Do you really want to menu 1 reinitialize E 1 was selected the system will reset 3 17 VIEW STATION CONFIGURATIONS The NC300 provides for scanning of various station parameters and is useful in checking programmed information The system will scan all remote stations and provide information including system port connection unit address SPUA room number bed number s assigned zone s station priority paging privacy OFF and code ON OFF Scanning all stations can be used to list station addresses during programming Remote stations may be scanned individually and for common settings including code call ON OFF status routine personal attention or priority call types R routine PA personal attn P priority privacy ON OFF status paging OFF status and staff stations Staff station scan also displays information for duty and utility stations Master stations are scanned for port connection unit address PUA assigned console master number display number assigned zones and binary address Zone scanning for all remote stations assigned to a common zon
9. External Connections From Hospital Grade TV UL 1410 Listed 412 VDC 12 VDC Power Supply Orange TV Control Green Audio amp Switch Common IR311B Station Blue Audio Note Power supply other than Top View Nurse Call is required 1 2 Watts per RY350B unit Note This should be duplicated for Dual Patient Stations IR312B Brown Red Orange Yellow Green Blue m Purple Note for remaining connections see NL401 wiring diagram RY350B WIRING DIAGRAM DATE 11 03 94 NC300 NURSE CALL SYSTEM PAGE NL407 urojs S esINN 09 subir v jeubis 9 punos euopyar 1ubu do 7 PIN CONNECTOR IR300B STATION Purple Blue Green Yellow Orange Red Brown 6 PIN CONNECTOR IR300A STATION Blue Green Yellow Orange Red Brown 112 VDC CORD OUT INPUT IN USE LED OUTPUT CALL INPUT 12 VDC CANCEL INPUT 12 VDC AUDIO OUT AUDIO OUT 12 VDC CALL LED INPUT CALL INPUT 12 VDC CANCEL INPUT 12 VDC AUDIO OUT AUDIO OUT TekTone 7 PIN CONNECTOR IR311B IR312B STATION Purple Blue Green Yellow Orange Red Brown 6 PIN CONNECT
10. 6 7 PRIORITY CALLS TEST PROCEDURE After the master console and patient stations have been programmed as outlined in the System Configuration Pro gramming Section 3 0 page 13 as for Patient Priority the following procedure should be used to confirm that the system is operating properly A Initiate a call on each station one at a time as described in the 4 0 SYSTEM OPERATING INSTRUCTIONS Section Check to confirm that the calls are displayed in highest priority first then the next in the order shown on page 19 Check to confirm that the highest priority calls are shown in the call box for each zone 1 Place alow priority call first then a higher priority call to insure that the lower priority call is replaced with the higher priority 2 While TALK button is pressed to initiate com munication to a lower priority call initiate an EMERGENCY BATH FIRE or CODE CALL to insure that the system interrupts and directs the communications to the emergency Copyright TekTone Sound amp Signal Mfg Inc All Rights Reserved the best NC300 Microprocessor Nurse Call System Port Programming Sheets Copyright TekTone Sound amp Signal Mfg Inc All Rights Reserved IL421 Tek MICRO Nurse Call System Manual 41 42 421 Tek MICRO Nurse Call System Manual Copyright TekTone Sound amp Signal Mfg Inc All Rights Reserved Port 1 Program
11. IR Series Patient Duty Staff Stations Before wiring patient duty and staff stations must be programmed by setting station addresses Each station on the same port must be addressed differently Determine the number of talk paths desired and then how the stations will be divided among the available ports Each master station provides for one separate talk path For example 32 stations may be divided among two ports if two masters are being used and two talk paths are desired even though all 32 stations may be contained on one port Once stations are assigned to a specific port and master station addresses may be made Refer to the following notes and Fig 7 for setting addresses 1 Set separate station addresses using DIP switch located on station PCB s See Fig 7 for location of DIP switch on circuit board and values assigned to each switch 2 Station addresses are comprised of 4 digits The first digit is 8 and is a system default Master on NC350CP Series system default is 8 Default for slave system is 7 The second digit will be either 1 2 3 or 4 and will correspond to the port to which the stations are connected The third and fourth digits are determined by DIP switch settings EXAMPLE For a station number of 8100 8 is the system default the station is connected to station port and all DIP switch s are in OFF position 421 Tek MICRO Nurse Call System Ma
12. Turn key to OFF position on associated IR316 2 Push cancel button on the SF336 OR 3 Turn key on the IR316 to the OFF position if call originated from an SF338 47 SF350B NURSE AIDE PRESENCE STATION Refer to Fig 23 for locations names and functions of controls and indicators Refer to WIRING DIAGRAMS NL401 NL405 and NL415 for wiring outputs provided for dome light indica tion A brief description of the operating controls for the SF350B follows Nurse Registration Button The nurse registration button green is used to transmit a nurse present signal to the master station and resets any routine personal attention or priority call made from the room where the nurse is registered The same button is used to cancel the nurse present indication Aide Registration Button The aide registration button yellow is used to transmit an aide present signal to the master station and resets any routine personal attention or priority call made from the room where the aide is registered The same button is used to cancel the aide present indication Nurse Registration Light The green LED flashes to indicate a nurse service request has been placed from the master station remains on steady to indicate nurse presence has been registered and is canceled when the nurse registers out Aide Registration Light The yellow LED flashes to indicate an aide service request has been placed from the master station remains
13. Code A Code B Negative 12 VDC Lamp Fault Red Lamp Green Lamp Yellow Lamp White Lamp LED Output Audio Audio 12VDC Data Com Data Out Data In Negative 24VDC 16 gauge Ground Wire e215piN 15 Green White 14 Yellow White 13 Orange Whitel__ 12 Red White 11 Brown White 10 Black White x Gra Purple Yellow Orange Red i Im lw ui o oo Brown v 2 8 PIN Gray Brown Purple Blue Green Yellow Orange Red Js 4 loo 6999906 NC300 WIRING DIAGRAM LI384A MULTIPLE STATIONS NC300 NURSE CALL SYSTEM DATE PAGE 04 20 95 NL416 DB9 FEMALE CONNECTOR NC362 VIDEO CARD SERIAL PORT RECEIVE DATA SHIELD SIGNAL GROUND TRANSMIT DATA GROUND TRANSMIT DATA SIGNAL GROUND RECEIVE DATA RTS DB9 FEMALE CONNECTOR C362 VIDEO CARD SERIAL PORT TRANSMIT DATA RECEIVE DATA RECEIVE DATA TRANSMIT DATA DCD CTS DSR 1 8 DTR DTR CTS DSR DCD SIGNAL GROUND SIGNAL GROUND DB9 FEMALE CONNECTOR NC362 VIDEO CARD SERIAL PORT SIGNAL GROUND GROUND RECEIVE DATA TRANSMIT DATA TRANSMIT DATA RECEIVE DATA DTR DSR DSR RTS RTS DCD CTS SIGNAL GROUND
14. d ibed bel PRIORITY sections as described below Low Priority STAFF DUTY Power Control Controls power ON OFF to video monitor PERSONAL ATTENTION LED lights when power is ON ROUTINE COMM FAULT Contrast Control Adjusts screen contrast Brightness Control Adjusts screen brightness Call Number Calls are displayed in order of origination and priority Each call is assigned a call number located at the extreme left of the call screen Room Number Room number for each calling station is dis played The number following the dash indicates bed number and will be highlighted when appearing in the call window Priority Calls may have one of the following priority levels listed in order of priority and a field programmable overtime reminder The letters OT appear after any call that has gone unanswered for more than the preset overtime limit If the call overtime is exceeded on a service request a call will be placed to the associated patient station from the master station 24 IL421 Tek MICRO Nurse Call System Manual Note Not tested as a fire alarm system Not intended as a primary evacuation means Note Any of the unused video outputs video that does not have a master connected to it display ALL CALL types System Status Priority System status priority calls are generated by faults within the system and will appear on the video screen System status calls are canceled only at such time
15. 1 Master 1 must be connected to Master Port 1 Master 2 must be connected to Master Port 2 etc reset master please follow the subsequent instructions Master Port 1 Master stations are addressed using DIP switches 1 2 and 3 only Set DIP switch drawings according to Figure 9 page 23 Example Master 1 DIP switch 1 Master 2 DIP switch 2 ON Master 3 DIP switch 1 2 ON Master 4 DIP switch 3 ON This number also serves as the assigned master station number and is used in master to master communications Example Master 1 01 Ports on the CPE are identified as previously mentioned A master station can be added and or deleted but it must be connected in sequential ascending order No internal wiring is necessary A VOLUME CONTROLS All controls are preset at factory The following is alist of volume controls found in Fig 8 All controls clockwise Increase Call Tone Volume Adjust this control for higher or lower incoming call tones Master Talk Volume Controls talk volume from master to stations Handset VOX Sensitivity Controls VOX circuit sensi tivity handset switching B IR315B Duty Station The Duty Station call tone and volume is adjustable via the three pin header located as shown in Figure 6 page 11 2 8 CONNECTIONS CHECK OUT Re check all connections to equipment If all wires and connections are satisfactory plug in CPE to dedicated outlet and turn p
16. 1251 8251 1 1252 8252 1 1253 8253 1 1254 8254 1 1255 8255 1 1256 8256 1 1257 8257 1 1258 8258 1 1259 8259 1 1260 8260 1 1261 8261 1 1262 8262 1 1263 8263 1 Example of how information appears on View Station menu 1232 8232 1 1 2 3 P ON OFF OFF SPUA System Port Unit Address PRIOR of station Routine or P Priority or PA Personal Attention ZONE NO Zone Station is programmed for System PAG Paging set on or off zone will default to physical port station is PRV Privacy set on or off connected to CODE Onoroff 46 ILA21 Tek MICRO Nurse Call System Manual Copyright TekTone Sound amp Signal Mfg Inc All Rights Reserved Port 3 Programming Sheet SPUA Default ASSIG BED ZONE NO PRIOR PAG PRV CODE LABEL RM BED ROOM R P PA ON OFF ON OFF ON OFF 1300 8300 1 1301 8301 1 1302 8302 1 1303 8303 1 1304 8304 1 1305 8305 1 1306 8306 1 1307 8307 1 1308 8308 1 1309 8309 1 1310 8310 1 1311 8311 1 1312 8312 1 1313 8313 1 1314 8314 1 1315 8315 1 1316 8316 1 1317 8317 1 1318 8318 1 1319 8319 1 1320 8320 1 1321 8321 1 1322 8322 1 1323 8323 1 1324 8324 1 1325 8325 1 1326 8326 1 1327 8327 1 1328 8328 1 1329 8329 1 1330 8330 1 1331 8331 1
17. 60 IR316 STATION WIRING DIAGRAM 409 61 CONNECTOR CIRCUIT INTERCONNECTIONS FOR ADDRESSABLE STATIONS NLA10 62 IR300B SERIES CONNECTIONS TO PERIPHERAL DEVICES NL411 263 PM321B PM322B LAMP MODULE WIRING DIAGRAM NL412 64 INSIDE LAYOUT NC350C CPE 413 265 RY351B WIRING DIAGRAM NLA14 66 14386 DOME ZONE LIGHT WIRING DIAGRAM NL415 267 LI384A MULTIPLE STATIONS NL416 268 NC362P VIDEO amp SERIAL CARD WIRING DIAGRAM NLA17 0222 4 000851 69 NC300 MICROPROCESSOR NURSE CALL SYSTEM SUPPLEMENT TO MANUAL IL421 1 0 SYSTEM INTRODUCTION TheNC300 Nurse Call System is a supervised Dig In Dig Com 12 VDC 24 VDC Wiring microprocessor based nurse call system that provides a complete range of two way audio and visual signaling permitting communications between nursing staff and patients as well as staff to staff communications The master station and video monitor make up the nursing control station where patient calls are registered and displayed in order of priority and time of origin The control station provides facilities to locate or dispatch nursing staff manage patient priority and privacy monitor all emergency situations monitor code lamp communication station and CPE faults within the system perform system c
18. Fig 24 OPERATION TO PLACE CALL 1 the red lever or pull down on the 7 nylon cord attached IL421 Tek MICRO Nurse Call System Manual 33 B TOCANCEL A CALL 1 Push the red lever to the UP position Calls may be reset only at point of origin 49 SF340B PULL PULL CORD EMERGENCY CALL STATION Refer to Fig 25 for locations names and functions of controls and indicators Refer to WIRING DIAGRAMS NL401 NL405 and NL415 for wiring outputs provided for dome light indica tion A brief description of the operating controls for the SF340B follows Emergency Pull Down Reset Lever The emergency pull down lever is used to place and cancel EMERGENCY and BATH calls Call Placed Light The red LED flashes to indicate call place ment T kTone Call Placed Light m Emergency EMERGENCY Pull Down Reset Lever Guide Tab O Call Cord _ Field Installation option refer to Sec 2 2 Fig 25 OPERATION TO PLACE A CALL 1 on the red lever or pull down on the 7 nylon cord attached B TOCANCEL A CALL 1 Push the red lever to the UP position Calls may be reset only at point of origin 34 421 Tek MICRO Nurse Call System Manual 4 10 LI380 LI384A LI386 DOME ZONE LIGHTS The LI380 and LI384A Dome Zone Lights provide for local i
19. junction with the IR316 Psychiatric Station A centrally located push button switch enables all emergency signals and 15 enabled only after the key switch located on the associated IR316 is activated A red call placed indicator on the SF336 SF338 flashes when a call has been placed Reliable solid state components and plug in connectors are mounted on a rugged stainless steel panel The SF336 includes a reset button SE350B Nurse Aide Presence Station The SF350B Nurse Aide Presence Station provides push button registration of nurse or aide presence at remote locations The station may also be used to transfer nurse follower feature from room location to room location The station consists of separate push button switches and light indicators green for nurse registration yellow for aide registration SF350B circuitry is mounted on a durable flame retardant plastic panel LI380 Dome Light The LI380 Dome Light provides visual indication of calls originating from patient staff duty bath emergency and code call stations and of nurse aide presence registration Patient priority and staff presence are indicated by red green yellow and white lamps The LI380 functions as a zone light when used with the IR315B Duty Station The LI380 consists of four bulbs covered by translucent plastic covers and mounted on a cycolac plastic base LI384A Dome Light The LI384A Dome Light provides for bulb supervision with fault indicati
20. 3 Press AIDE yellow button on master to cancel aide service Page a zone by pressing PAGE gray button then entering a zone number as described the System Operating Section 4 0 page 23 Check for following at master station 1 PAGE appears in call window Press TALK white button Check for following at master station 1 TALK button LED steadily illuminated 2 PAGE remains in call window 3 Communications established to all zoned patient stations within zone selected Check for following at all zoned patient stations 1 Reset In use light steadily illuminated Press RESET black button Check for following at master and patient stations Allsignals canceled Page all assigned zones by pressing PAGE gray button then TALK white button Check for following at master station 1 TALK white button LED steadily illuminated 2 ALL appears in call window if the total number of stations paged per port is more than 30 PAGE appears in call window if the total number of stations paged per port does not exceed 30 3 Communications one way for more than 30 sta tions paged per port two way for less than 30 per port established to all zoned patient stations Check for following at all zoned patient stations 1 Reset In use light steadily illuminated Press RESET black button Check for following at master and patient stations 1 All si
21. AIDE yellow NURSE green FOLLOW orange Terminates most operations Enters an aide service request Enters a nurse service request Initiates nurse follower operations LED lights while nurse follower is in use Enters an urgent STAT service request for a nurse or aide Displays the system menus and permits selection of less used functions Displays MENU for entering room numbers of areas to be monitored Displays MENU for reassignment of MASTER S Zones Page Down STAT red MENU blue MONITOR blue CAPTURE blue PRIVACY blue Copyright TekTone Sound amp Signal Mfg Inc All Rights Reserved FUNCTION BUTTONS NUMERIC KEYPAD MICROPHONE TRAY FOR QUICK REFERENCE GUIDE CALL LIGHT VIEW blue PRIORITY blue TONE ON It gray Turns ROUTINE call tone on or off LED flashd Tone signals are as follows Page Up Displays for setting ROOM PRIORITY status High Priority FAST REPEATING TONE Medium Priority SLOW REPEATING TONE Low Priority ONE TONE REPEATED EVERY 8 SECONDS CPE Fault Priority STEADY TONE Beep Tone Switch Beeps when function keys and keypad numbers are pressed It is DIP switch 8 Place switch down to turn ON Call Light The call light flashes slowly for low priority calls flashes at a medium rate for medium priority calls and flashes at a fast rate for high priority calls CPE Fault Light The fault light
22. Data In Data Out Data Common Must be low capacitance wire less than 23 picofarads per foot 1 twisted pair 18 w overall shield IR300B SERIES STATION TITLE NC350CP WIRING DIAGRAM DATE 12 23 98 m USING INDIVIDUAL CABLES APP NC300 NURSE CALL SYSTEM PAGE 403 Tenue A urojs S 9811 N eOUOIN AAL 95 9 punos auoLyal o 3u6uAdo5 subi DUI Minimum Cable Requirements for DSN NC350CP DSN 9 Pin DSN 9 Pin Connector Cable Connector Cable Purple Pin 1 EE p Purple Pin 1 Gray 2 Audio Pair ae Gray Pin 6 Shields Shield NC350CPX2 YellowPin4 oS Yellow Pin 4 NC350CPX2 Orange Pin 9 Data Pair 2 lt Orange Pin 9 Dual System Network 9 Shield 2 Dual System Network CPE Link Card 9 Pin Connector gt lt Link Card 9 Pin Connector Audio Pair 1 pair shielded 18 separate cable Data Pair 1 pair shielded 18 separate cable All Call amp Control 1 pair shielded 18 separate cable Maximum distance 500 ft Shields should connect at one end only to their own connector cable TITLE Dual System Network Wiring DATE 03 18 99 Specifications APP NC300 NURSE CALL SYSTEM PAGE NL404 IR300B IR 301B IR 302B IR 310B IR 311B IR 31
23. Example of how information appears on View Station menu 1301 8301 1 1 2 R ON OFF OFF SPUA System Port Unit Address PRIOR of station R Routine or oe P Priority or PA Personal Attention ZONE NO Zone Station is programmed for System PAG Paging set on or off zone will default to physical port station is PRV Privacy set on or off connected to CODE Onoroff Copyright TekTone Sound amp Signal Mfg Inc All Rights Reserved ILA21 Tek MICRO Nurse Call System Manual 47 Port 3 Programming Sheet SPUA Default ASSIG BED ZONE NO PRIOR PAG PRV CODE LABEL RM BED ROOM R P PA ON OFF ON OFF ON OFF 1332 8332 1 1333 8333 1 1334 8334 1 1335 8335 1 1336 8336 1 1337 8337 1 1338 8338 1 1339 8339 1 1340 8340 1 1341 8341 1 1342 8342 1 1343 8343 1 1344 8344 1 1345 8345 1 1346 8346 1 1347 8347 1 1348 8348 1 1349 8349 1 1350 8350 1 1351 8351 1 1352 8352 1 1353 8353 1 1354 8354 1 1355 8355 1 1356 8356 1 1357 8357 1 1358 8358 1 1359 8359 1 1360 8360 1 1361 8361 1 1362 8362 1 1363 8363 1 Example of how information appears on View Station menu 1332 8332 1 1 2 3 R P ON OFF OFF o GNE m FONE NO 5 PM elt programmed for S ystem PAG Paging set on or off zone
24. Reset KITCH PER ATN Call KITCH PER ATN Reset WEST MONITOR Call WEST MONITOR Reset SOUTH EMER Call SOUTH EMER Reset EAST BATH Call EAST BATH Reset ZONE 12345678 12345678 12345678 12345678 12345678 12345678 S 12345678 12345678 12345678 12345678 STN 8104 8104 8105 8105
25. Select 4 from Main Menu Select 4 from System Function Menu Select 6 from Reconfiguration Menu Enter the Room and Bed number Select the number of the label to be used for the selected room number and press the 4 key 7 Press the key to save Dy ASP Choose A Label Menu Figure 5 CHOOSE LABEL 1 NORTH 6 TUB 11 LUNCH 16 ICU 2 SOUTH 7 SHWR 12 KITCH 17 THRPY 3 EAST 8 REHAB 13 LINEN 18 OR 4 WEST 9 PSYCH 14 STAIR 19 ER 5 PUBLC 10 LOUNG 15 DOOR 20 LAB ROOM _______ ___ LABEL menu enter enter room id 2 2 Change A Standard Label Changes to the 5 character field are menu driven with the letters of the alphabet A through Z along with the numbers 0 through 9 and special characters Selecting option 7 from the Reconfiguration Menu shown in Figure 3 displays the follow ing two menus for programming Change A Standard Label Menu Figure 6 CHANGE LABEL 1 NORTH 6 TUB 11 LUNCH 16 ICU 2 SOUTH 7 SHWR 12 KITCH 17 THRPY 3 EAST 8 REHAB 13 LINEN 18 OR 4 WEST 9 PSYCH 14 STAIR 19 ER 5 PUBLC 10 LOUNG 15 DOOR 20 LAB enter enter label no menu The above menu is used to customize the standard room labels When changing a label on this menu the old label will be erased Any room numbers using the old label will be updated The new label will be displayed in the menu giving the abilit
26. and 9 used on NC350CP Series 8 and 9 not present on NC350C 64 A Press MENU blue button MAIN MENU Help Menu Master Assignments Menu User Function Menu System Function Menu SetRoom Privacy Page Room Monitoring Radio Pager Menu exit select menu item Select Set Room Privacy and Page by pressing 5 on keypad SET ROOM PRIVACY AND PAGE 1 SetRoom Privacy 2 SetRoom Page prev menu select menu item C Select Set Room Privacy by pressing 1 on keypad SET ROOM PRIVACY Room amp BedNo 2 Privacy Status menu enter enter room id D Enter room and bed number SET ROOM PRIVACY Room amp Bed No 8101 1 Privacy Status ON save 1 toggle selection E Select PRIVACY ON OFF by pressing 1 on keypad Press to save When a station is programmed for privacy the patient may call the nurse and hear a reply and paging from the master station will be heard A call can be placed from the master station but no audio can be heard If two way communication with a station in privacy mode is desired the operator at the master station can request the patient place a call after the current call is reset from the Master only All visual signals function as normal when the callis initiated from the patient station Master stations cannot be progra
27. menu select menu item C Select Reconfiguration by pressing 4 on keypad RECONFIGURATION Program Menu Reinit System Define Password Set Reset Code Call Add Del Station prev menu select menu item D Select Add Delete Station by pressing 5 on keypad ADD DELETE STATION RoomNo 2 _ Room Status menu enter enter room id The Add Delete Station menu above allows the addition or deletion of stations from the system without reinitialization The software is modified so that each station has a specific address from 0 to 31 0 63 on the NC350CP Series CPE For existing installations where the DIP switches for the station devices is set outside this range it will be necessary to readdress these devices When the system is turned on the new station will be assigned a number in the 8000 5 depending on what port they are connected to and their position in the polling loop For example The station for port 2 on the NC350C 64 would be 8200 8231 The station for port 2 on the NC350CP Series would be 8200 8263 It will then become necessary to program the new station as desired The new station must be addressed differently than all other stations connected to its related port When physically removing a station the system must first be powered down When the system is turned on again it will report a COMM FAULT for
28. no indication on LI384A High Priority FAST REPEATING FLASH Medium Priority SLOW REPEATING FLASH Low Priority STEADY LAMP Copyright TekTone Sound amp Signal Mfg Inc All Rights Reserved 5 0 SYSTEM MAINTENANCE INSTRUCTIONS The following section provides information regarding NC300 System user serviceable parts and their replacement Any equipment not listed in this section is not user serviceable and should not be replaced or repaired by other than qualified service personnel 5 1 NC303 MASTER STATION A Defective Handset Replacement 1 Toremove handset from cord grip end of modular plug on cord firmly and squeeze until cord is easily pulled away from handset 2 To replace handset hold end of plug on the cord squeeze and push straight into receptacle on hand set Release and plug will click into place 3 To test handset place a call to a patient station and establish communication using the handset 52 IR301B IR302B PATIENT STATIONS A Defective Call Cord Replacement 1 To remove call cord grip end of plug firmly and pull straight away from station 2 To replace call cord hold by end of plug and push straight into call cord jack on station 3 To test call cord initiate a call Call placed light should illuminate Push the reset button to cancel call 5 3 IR311B IR312B PATIENT STATIONS A Defective Call Cord Pillow Speaker Replacement 1 remove call cord grip end of modular plug firmly and
29. slowly flashing Check for following at master station 1 Call light slowly flashing 2 Tone signal slowly repeating 3 Call information appears on call screen with call priority indication of BATH Check for following at duty station in the same zone 1 Call placed light and emergency light alternately flashing 2 Tone signal slowly repeating 3 Dome light white lamp slowly flashing Reset each emergency station as described in the Sys tem Operating Section 4 0 page 23 Check for following at emergency patient duty and master stations 1 All signals canceled 6 5 SF341B CODE STATION TEST PROCEDURE A Initiate a call on each station one at a time as described in the System Operating Section 4 0 page 23 Check for following at code call and emergency station 1 Call placed light rapidly flashing Check for following at associated patient station 1 Call placed light rapidly flashing 2 Dome lights white and red lamps alternately rapidly flashing for call placed from code call station Dome light white lamp rapidly flashing for call placed from staff emergency station Check for following at master station 1 Call light rapidly flashing 2 Tone signal rapidly repeating 3 Call information appears on call screen with call priority indication CODE CALL for code call station Check for following at duty station in the same zone 1 Call placed light and emergency light a
30. the OFF position SE337C Pull Pull Cord Waterproof Shower Emergency Call Station If the red pull down lever has been pulled reset the call by returning the lever to the UP position SE340B Station Emergency If the red pull down lever has been pulled reset the call by returning the lever to the UP position SE341B Code Emergency If the blue pull down lever has been pulled reset the call by returning the lever to the UP position SE350B Presence Station Green and yellow lights should not be illuminated Press green and or yellow button s to cancel 6 1 IR301B IR302B IR310B IR311B IR312B IR318 PATIENT STAFF STATION TEST PROCEDURE A Initiate a call on each patient or staff station as de scribed in the System Operating Section 4 0 page 23 On dual stations both circuits should be tested The chart provided for listing assigned room numbers should be filled in at this time Check for following at patient stations 1 Call placed light flashing 2 Dome light white lamp on steady Check for following at master station 1 Call light flashes every 8 seconds 2 Tone signal every 8 seconds 3 Call information appears on call screen with call priority as follows 36 IL421 Tek MICRO Nurse Call System Manual IR301B IR302B IR311B IR312B IR318 Routine or Personal Attention IR310B Staff Check for following at duty station in the same zone 1 Call placed light flashing 2 To
31. 1 1207 8207 1 1208 8208 1 1209 8209 1 1210 8210 1 1211 8211 1 1212 8212 1 1213 8213 1 1214 8214 1 1215 8215 1 1216 8216 1 1217 8217 1 1218 8218 1 1219 8219 1 1220 8220 1 1221 8221 1 1222 8222 1 1223 8223 1 1224 8224 1 1225 8225 1 1226 8226 1 1227 8227 1 1228 8228 1 1229 8229 1 1230 8230 1 1231 8231 1 Example of how information appears on View Station menu 1201 8201 1 1 2 3 R P ON OFF OFF SPUA System Port Unit Address PRIOR of station R Routine or ids P Priority or PA Personal Attention ZONE NO Zone Station is programmed for System PAG Paging set on or off zone will default to physical port station is PRV Privacy set on or off connected to CODE On or off Copyright TekTone Sound amp Signal Mfg Inc All Rights Reserved 1421 Tek MICRO Nurse Call System Manual 45 Port 2 Programming Sheet SPUA Default ASSIG BED ZONE NO PRIOR PAG PRV CODE LABEL RM BED ROOM R P PA ON OFF ON OFF ON OFF 1232 8232 1 1233 8233 1 1234 8234 1 1235 8235 1 1236 8236 1 1237 8237 1 1238 8238 1 1239 8239 1 1240 8240 1 1241 8241 1 1242 8242 1 1243 8243 1 1244 8244 1 1245 8245 1 1246 8246 1 1247 8247 1 1248 8248 1 1249 8249 1 1250 8250 1
32. 9 STATION ZONE ASSIGNMENTS ZONE 1 2 3 4 5 6 7 8 Room 8100 Label bed1 1 bed 2 2 menu enter enter room id Press and the bed number and the following menu appears Figure 10 STATION ZONE ASSIGNMENTS ZONE 1 2 3 4 5 6 7 8 Room 8100 Label bed 1 1 bed 2 2 enter none 0 default 1 custom If the user selects none the following menu appears and the room is programmed with no label Press to save Figure 11 STATION ZONE ASSIGNMENTS ZONE 1 2 3 4 5 6 7 8 Room 8100 1 1 2 2 Label NORTH enter 1 9 assign zones save If choice 0 is selected in the menu shown in Figure 10 the menu shown in Figure 12 will appear and the user can type the number of the label desired and to save CHANGE LABEL Figure 12 1 NORTH 6 TUB 11 LUNCH 16 ICU 2 SOUTH 7 SHWR 12 KITCH 17 THRPY 3 EAST 8 REHAB 13 LINEN 18 OR 4 WEST 9 PSYCH 14 STAIR 19 ER 5 PUBLC 10 LOUNG 15 DOOR 20 LAB LABEL menu 1 20 select label If choice 1 is selected in the menu shown in Figure 10 the user can input a custom and unique label for this room Press the ALPHA key and type new label 5 character limit Press 4 key to save 11421 Tek MICRO Manual Supplement 52 Help Menu Help Menu Answer a Call Place a Call Request Nurse Asst Stat Service Use Call Fol
33. AIDE FOLLOWER orange button Nurses register their whereabouts by pressing the NURSE AIDE button on the SF350B Presence Station The room number where the nurse is registered will appear in the NURSE area on the call screen If presence stations are not used call tones may still be sent to specific rooms as indi cated in step 2 NOTE Pressing the NURSE FOLLOWER button cancels the currently se lected call as this is the room to which the nurse should be responding first Only one master at a time may use nurse follower for masters assigned to the same zone No restric tions apply for masters assigned to different zones PAGE UP DOWN FEATURE If more than 16 calls are displayed on the screen the rest of the calls can be seen by pressing the Page Up Down keys 1 Page Up View Key 2 Page Down Privacy Key TO OPERATE RADIO PAGER The pager software addition to TekTone s NC300 Nurse Call System provides the capability of selectively sending event messages to radio pagers Up to 48 Radio Pagers can supported each uniquely identified by its 3 digit number Pagers can be assigned to receive messages both by zone of origin and by call type Pager assignments are user programmable from the menu system The NC300 Software Version 1 94 or higher or optional NC363 for printer and pager at the same time is designed to operate paging functions using the available printer pager port as the connect
34. Blue insulated by 015 thick PVC One 16 gauge stranded wire The conductor is Black insulated by 016 thick PVC TITLE BLOCK WIRING DIAGRAM APP NC300 NURSE CALL SYSTEM NOTES 1 2 DO NOT EXCEED 16 DOME LIGHTS PER RUN DO NOT EXCEED 16 STATIONS PER RUN WHEN USED WITH 4 LAMP DOME LIGHTS UP TO 32 STATIONS MAY BE USED PER CABLE RUN IF SINGLE OR DOUBLE DOME LIGHTS ARE USED EACH MASTER MUST BE HOME RUN TO NC350C CENTRAL PROCESSING EQUIPMENT CPE FOR RUNS OF 500 TO 1000 FT USE 18 GAUGE WIRE FOR RUNS OF 1000 TO 1500 FT USE 16 GAUGE WIRE RUN SHOULD NOT EXCEED 1500FT DO NOT RUN CONDUIT OR WIRE TO BOTTOM KNOCKOUTS ON IR SERIES STATION BOX NO ACCESS IS AVAILABLE MATL DE REV 10 DATE 03 18 99 PAGE NL402 subi jeubis 9 punos euopyar 3ubu do CG ENUEN 1545 ISMN POMOIN IAL NC350CPX2 CPE NC350CP Cable Requirements Using Individual Cables Maximum number of stations on any one cable run 32 Maximum number of stations on a port 64 Note Total combined cable lengths using 18 wire cannot exceed 1000 ft Total combined cable lengths using 16 wire cannot exceed 1500 ft 9 pin Pigtail Total Cable on any port is 1500 ft V To Next Station on System 1 Cond 16 ESD Ground 3 Cond 18 shielded with drain wire 424 12 Negative Maximum 1000 ft 16 max 1500 ft 1 twisted pair 18 plus 1 cond 18 w overall shield
35. CANCEL A CALL 1 Push the blue lever to the UP position Calls may be reset only at point of origin 4 6 SF336 SF338 STAFF EMERGENCY PSYCHIATRIC STATIONS Refer to Fig 22 for locations names and functions of controls and indicators Refer to WIRING DIAGRAMS NLA01 NL405 and NL415 for wiring outputs provided for dome light indica tion A brief description of the operating controls for the SF336 SF338 follows Staff Assist Button Depressing the centrally located push button enables all emergency signals only after activation of the key switch located on the associated IR316 Psychiatric Station Cancel Button The red call placed light flashes to assure a call has been properly placed Call cancellation is only possible at point of origin NOTE The SF338 does not have a Cancel Button Call cancellation is only possible at IR316 Call Placed Todos Light STAFF ASSIST Staff Assist Staff Assis Button i Cancel Button Note SF338 L does not have a CANCEL cancel button Fig 22 Copyright TekTone Sound amp Signal Mfg Inc All Rights Reserved OPERATION A TO PLACE A CALL 1 Turn key to ON position on associated IR316 2 Pushcentrally located staff assist button on SF336 SF338 A red call placed indicator on the SF336 SF338 flashes to assure a call has been placed B TO CANCEL CALL
36. DISABLE PAGER Press to save Press 1 to SELECT MOTOROLA Press 4 to save Press 2 to SELECT Press to PAGER ROOM ASSIGNMENTS 400 408 416 424 432 440 401 409 417 425 433 441 402 410 418 426 433 442 403 411 419 427 434 443 404 412 420 428 435 444 405 413 421 429 436 445 406 414 422 430 437 446 407 415 423 431 438 447 Room Bed No 8101 1 down 0 up 1 toggle status 2 After you have entered valid room number and ID you can select which pagers you want to be assigned to that room Press to scroll up or to scroll down to the specific pager number then press 1 to toggle on or off A next to the pager number indicates not selected x next to the pager number indicates that it is selected Press 2 to save 3 27 EXECUTE A PAGE By entering a pager number and then selecting 0 9 a message can be sent to the specific pager number Up to 50 messages are predefined 10 messages are displayed at a time an extension of up to 6 characters can be added at the end of each message save Protocols are as follows Motorola comp 2 mode 9600 BAUD 8 bits no parity 1 stop bit Interpage 9600 BAUD 8 bits no parity 1 stop bit 3 26 ASSIGN PAGER TO ROOM Assigns room numbers to pagers on system Any or all of the 48 pagers can be a
37. Define Password Set Reset Code Call Add Del Station Choose a Label Change a Label MOUBUuUNm prev menu select menu item 2 0 ROOM LABEL OVERVIEW A five 5 character field has been added for each room number thatis alphanumeric in data type with a leading and trailing blank for separation This field is located between the room bed num ber and type of call Figure 4 below is a representation of the NC310B VIDEO MONITOR and shows the addition of the Room Label and the abbreviation of the call type Figure 4 ROM LABEL NURSE AID STAT REGIA TION CALL NUMBER 1 8100 1 ROUTINE 8100 8100 8100 4 STAT REQUEST ROOM NUMBER BED ID NUMBER REGISTRATION CALL PRIORITY NURSE REGISTRATION CLOCK CALL WINDOW TONE OFF amp NURSE FOLLOW ON INDICATION The Room Label field is programmed in the same manner as the Room Number and can be any field description that the user programs or the field can be selected from standards provided up to 5 characters It is password protected as will be the room programming process 51 11421 Tek MICRO Manual Supplement 2 1 Choose A Standard Label This function allows the user to insert a label for any room programmed in the system The menu shown in Figure 5 is used to choose a label corresponding to the selected room number The necessary key strokes are as follows 1 Press MENU
38. MASTER port 1 C2 MASTER port 2 etc 4 7 b DIP switch setting of masters See Figure SUP 1 for correct setting Note If none of the above correct MASTER FAULT corrupt data has been saved In this unlikely event follow the steps listed below 1 Turn NC350C CPE off 2 Insert key and turn counter clockwise Key switch is located on the front panel of NC350C CPE 3 Turn CPE on 4 If master operates correctly all current data must be erased To erase all data I Press MENU key on NC303 II Press 3 III Press 4 IV Press 2 V Turn key switch to original position VI Press 1 MASTER 1 1 2 3 4 MASTER 2 E 1 2 3 4 MASTER 3 0 1 2 3 4 MASTER 4 V Fig SUP 1 No video display on NC310B monitor Check a 117 VAC connection at NC310B Monitor b 117 VAC connection at NC350C CPE c ON OFF switch at NC310B Monitor d ON OFF switch at NC350C CPE e Check NC350C CPE RUN red LED It should be flashing f Brightnessandcontrastcontrols at NC310B Moni tor g Field wiring for video Using test cable supplied connect NC310B Monitor directly to CPE Note Each system is supplied with outputs to four NC310 Monitors If all of the above fails and there are outputs available connect monitor to one of those IL421 Tek MICRO Manual Supplement 54 NO 0000 0001 0002 0003 0004 0005 0006 0007 0008 0009 0010 0011 0012 001
39. THE CABLE RUN DRAINS MUST BE KEPT SEPARATE FROM ONE ANOTHER AND ALL OTHER CONDUCTORS DRAINS CANNOT BE TOUCHING ANY PART OF METAL CONDUIT OR BOX PLEASE NOTE THE DRAIN WIRES ARE SHORTED TOGETHER AT THE CPE PIGTAILS PROVIDED Make sure the minimum number of conductors needed for all of the equipment being used in the system are available 2 6 WIRE CONNECTIONS STATION PROGRAMMING Make wire connections in accordance with the following infor mation and WIRING DIAGRAMS NL401 NL403 NL405 NL406 and NL415 All stations and CPE are supplied with cable assemblies terminated by plug in type connectors for easy wiring CAUTION Static electricity can cause damage to the stations The green ground wire found on all IR Series Stations must be connected to the 16 gauge system ground wire or to conduit A NC350CP Series Central Processing Equipment Each NC350CP Series CPE is supplied with eight cable assemblies terminated at one end by a male 9 pin D subminiature connector and stripped at the other These cables are plugged into the D subminiature port connectors located at the rear of the CPE and are supplied for master and patient duty staff station wiring Maximum system capacity requires use of 8 cable assemblies Smaller systems do not require use of all 8 assemblies Four ports maximum are available for connection to master stations and four ports maximum are available for connection of up to 32 patient staff or duty station
40. as the fault is corrected TROUBLE CODE indicates a fault in the code call circuit at one or more stations The specific station room number will be displayed on the call screen CODE FAULT indicates the following possible conditions Wires from code station to patient station open Wires from code station to patient station grounded or shorted to system wiring Defective code station Defective patient station Copyright TekTone Sound amp Signal Mfg Inc All Rights Reserved TROUBLE STATION indicates a fault in the wiring to one or more patient stations or a defective patient station The specific station room number will be dis played on the video screen with COMM FAULT indication NOTE If a fault occurs to several stations at the same time it indicates a probable wiring fault at the station nearest the CPE and showing a fault COMM FAULT see above indicates the following possible conditions Common wiring to station open shorted or grounded Defective station LAMP FAULT with associated room number in dicates the following possible conditions Dome lamp bulb defective or not in socket Wires from dome light to patient station open Common wiring to station or dome light open or shorted Defective patient station Lamp fault jumper not installed on patient station always installed except when LI384A Dome Light is used TROUBLE FAN indicates a fault i
41. at master station 1 NURSE FOLLOWER orange button LED ex tinguished 2 NURSEFOLLOWER ON removed from moni tor Initiate NURSE FOLLOWER to a specific room by selecting room number as for communications Check for following at master station 1 Room bed ID number appears in call window Press NURSE FOLLOWER orange button Check for following at master station 1 Call information canceled 2 NURSE FOLLOWER orange button LED on 3 NURSE FOLLOWER ON displayed on moni tor Place a call from any patient station in the same zone Check for following at patient station to which calls are sent 1 Reset In use light steadily illuminated 2 Calltone every 8 seconds Check for following at duty station in the same zone 1 Call placed light flashing Copyright TekTone Sound amp Signal Mfg Inc All Rights Reserved 2 Calltone every 8 seconds 3 Dome light white lamp on steady V Press NURSE FOLLOWER to toggle off Check for following at patient station to which calls are sent 1 signals canceled W TALK white button then RESET black button Check for following at master 1 signals canceled 6 3 SF336 SF338 STAFF EMERGENCY IR316 PSYCHI STATION IRO19C SPEAKER MICRO PHONE TEST PROCEDURE A Initiate acall on each patient or staff station as described in the System Operating Section 4 0 page 23 On dual stations bo
42. call screen Room bed ID number appears in call window Press TALK white function button Check for following at master station 1 TALK white button LED steadily illuminated 2 Communications established Check for following at patient station 1 Reset In use light steadily illuminated 2 Call placed light steadily illuminated 3 Communications established Press RESET black function button Check for following at master and patient station 1 All signals canceled Initiate a call to another master station as described in the System Operating Section 4 0 page 23 Check for following at master station 1 Call light flashes two times at called master 2 Two tones are heard at called master 3 Master station number called appears in call win dow 4 MSTR appears in call window of called master 5 TALK white button LED steadily illuminated IL421 Tek MICRO Nurse Call System Manual 37 at both masters E Pick up the handset at both master stations and speak in a normal voice Check for following at master station 1 Communications established through the handset Press RESET black button or hang up handset Check for following at master stations 1 All signals canceled Request nurse service by selecting room number as for communications then pressing NURSE green but ton Check for following at master station 1 Call number room bed ID numbe
43. ings each station must be programmed See WIRE CONNECTIONS STATION PROGRAMMING sec tion LI380 LI384A LI386 Dome Zone Lights Install double gang ring or double gang ring double gang box Steel City H2BD with 2GC or exact equiva lent as shown in Fig 2 for each corridor dome light in system Minimum dimensions of back box to be not less than 4 x 4 x 1 1 2 Minimum clearance from live parts on the station to dead metal parts to be not less than 1 2 8 1421 Tek MICRO Nurse Call System Manual ge Fig 2 NC303 Master Station NC310B Video Monitor The NC303 Master Station and NC310B Video Monitor are for desk or counter top mounting The NC310B may be wall mounted if desired Contact factory for custom mounting information Note A single gang box or ring must be installed for the wall plate provided with the NC303 NC350C 64 NC350CP Series Central Processing Equipment The CPE s are self contained in a PC type cabinet The unit may be desk or counter top mounted Contact factory for custom mounting information RY350B Multi Channel Relay For housing installa tion follow the instructions as in Section 2 4 item A RY351B Hill Rom SideCom Adapter Install dual gang back box Steel City number 52171 1 2 and 3 4 with 52 C 13 ring Use TekTone single gang plate cover PL301 PK352 Battery Charger Assembly The PK352 battery charger assembly is self contained in a steel cabin
44. is 3 7 INTERCOM PREANNOUNCE CALL TONES NOT ACTIVE Note Reinitializing system will not change DSN status When Intercom Preannounce Tones is enabled it will gen erate a 1 second tone when the TALK button is first 3 9 DSN ZONE CAPTURE NC350CP SERIES pressed to talk to a room station Note Default is ON Follow the procedure below to display or change the DSN Follow the procedure below to assign Preannounce Call Zone Capture Tones Note On Main Menu numbers 8 and 9 used NC350CP Series 8 and 9 not present on NC350C 64 A Press MENU blue button MAIN MENU A Press MENU blue button 1 Help Menu 2 Master Assignments Menu 3 User Function Menu MENU 4 System Function Menu 5 Help Menu 5 Set Room Privacy Page 5 Master Assignments Menu 6 Room Monitoring al Function Menu 1 Radio Pager Menu 4 Am Function Menu 8 Dual System Status 2 9 Dual System Zone Capture 7 Radio Pager Men exit select menu item exit select menu item B Select Dual System Zone Capture by pressing 9 B Select Master Assignments Menu by pressing 2 on on keypad keypad Dual System Zone Assignments MASTER ASSIGNMENTS DUM 2 E 1 Master Call Display 2 intercom Preannounce Tones ENTER ZONE NUMBER TO CHANGE STATUS prev menu select menu item exit save and exit 16
45. is steadily illuminated when failure of the central processing equipment CPE is detected Numeric Keypad The numeric keypad is used for entry of station numbers for zone and station selection and for other programming functions 421 Tek MICRO Nurse Call System Manual 23 Speaker The speaker is used for listening to remote stations and for call tones Microphone The microphone is used for talking to remote stations Hook Switch Option The hook switch activates or terminates handset operation Electrical rating 2MA 12vdc Tray Tray holds Quick Reference Guide of system operations NC310B Fig 10 STAFF ROOM LABEL NURSE AID STAT REGISTRATION CALL NUMBER 1 8100 1 ROUTINE 8100 8100 8100 4 STAT REQUEST ROOM NUMBER 7 AID BED ID NUMBER REGISTRATION CALL PRIORITY NURSE REGISTRATION CALL FOLLOW ON TONE OFF CLOCK CALL WINDOW TONE OFF amp NURSE FOLLOW ON INDICATION NC310B VIDEO MONITOR High Priority CODE CALL Incoming calls are displayed on the video monitor in plain FIRE supplementary only see note E EMERGENCY English The calls are displayed in order of origination and Medium Priority MONITOR priority with up to 16 calls displayed simultaneously Additional BED OUT calls are stored in memory and are identified by a MORE BATH CALLS WAITING message The call screen is divided into FORDOUT
46. squeeze until cord can easily be pulled straight away from station 2 To replace call cord hold by end of plug squeeze and push straight into the receptacle on station Release and plug will click into place 3 To test call cord initiate a call Call placed light should illuminate Push the reset button to cancel call Copyright TekTone Sound amp Signal Mfg Inc All Rights Reserved 5 4 LI380 LI384A LI386 DOME ZONE LIGHTS A Defective Bulb Replacement 1 Toremove cover grip firmly by sides and squeeze Pull cover away from plate 2 To remove bulbs hold by glass part push in and rotate counter clockwise then pull straight away from metal socket 3 Remove bulb covers if any and place on new bulb 4 Toreplace bulbs hold by glass part and push in and rotate clockwise into socket 5 Replace cover 6 To test lamps place calls at all stations necessary to test all lamp combinations NOTE Replacement of bulbs on LI384A Super vised Dome Zone Lights will cause a LAMP FAULT indication at the master station until the bulb is replaced 5 5 REPLACEMENT PARTS Part No Description Used For LIO28 lamp 28V LI380 LI384A LI386 Dome Zone Light SF301 call cord IR301 B IR302B Stations SF302 call cord dual IR301B IR302B Stations SF301 10 call cord 10 IR301B IR302B Stations SF302 10 call cord dual 10 IR301B IR302B Stations SF301P pillow speaker IR311B IR312B Stations SF301PIR pillow speaker IR3
47. station should be located for convenient operation usually near the room entrance and in the same room as the patient station to which nurse or aide presence indication is desired 2 3 WIRING INSTALLATION Wiring conduit may be run from dome light to dome light station to station or a combination of the two terminating at the Central Processing Equipment We recommend running con duit from dome light to dome light because of the reduced conduit lengths Each run should be limited to 16 or less corridor lights and 16 or less patient stations when used in conjunction with dome lights Up to 32 patient stations may be used per cable run 64 stations if a NC350CPX2 is used if no dome lights are used Select conduit size to accommodate the following cables A ltwisted pair shielded 18 plus 1 twisted pair shielded 18 individually jacketed plus 4 cond 18 plus 1 cond 416 If installing NC350CP SERIES WM300 cable cannot be used when connecting more than 32 stations per port Four separate cables must be used configured as follows twisted pair 18 gauge shielded low capacitance 23 pF ft data plus 1 twisted pair 18 gauge shielded audio plus 4 cond 18 gauge power cond plus 1 cond 16 gauge ESD If possible obtain the same color code as is used in the WM300 cable OR TekTone WM300 nine conductor cable assembly protected by a Gray PVC 045 thick jacket Nominal O D 590 Configured as follows Data Assembly c
48. step and enter the new password or press to cancel the password require ment 3 15 SET CODE STATION ON OFF For any IR Series Station wired to an SF341B Code Call Station the code station is set to ON at power up codes stations cannot be wired to duty stations If at alater date itbecomes necessary to disable the code call station the station must be reset OFF or a code fault will result Follow the procedure listed below Note On Main Menu numbers 8 and 9 used on NC350CP Series 8 and 9 not present on NC350C 64 Press blue button MAIN MENU Help Menu Master Assignments Menu User Function Menu System Function Menu SetRoom Privacy Page Room Monitoring Radio Pager Menu exit select menu item Select System Function Menu by pressing 4 on keypad SYSTEM FUNCTIONS Set Time Date 12 24 Hour Clock Set Overtime Reconfiguration Hook Switch prev menu select menu item Copyright TekTone Sound 6 Signal Mfg Inc All Rights Reserved Select Reconfiguration by pressing 4 on keypad RECONFIGURATION Program Menu Reinit System Define Password Set Reset Code Call Add Del Station prev menu select menu item D Select Set Reset Code by pressing 4 keypad SET RESET CODE CALL Room No Code Call St
49. that room until the station has been deleted from memory Note For existing installations where the DIP switches for the station device is set outside the above mentioned range it will be Copyright TekTone Sound amp Signal Mfg Inc All Rights Reserved 3 5 necessary to readdress these devices The deleted stations will be shown in the view ALL station menu with the deleted SPUA ft The view ALL menu below presents a record of the deleted stations as shown below SPUA ROOM BED ZONE NO PRIOR PAG CODE 1200 8300 1 3 R on off off 1301 8401 12 4 DELETED 2302 8402 4 staff on off off menu down A station can also be deleted if it is still physically in the polling loop Deletion will not shift the SPUA numbers because the device is still there but the presence of the device is ignored MASTER ASSIGNMENT MENU Master stations may be assigned to one all or any combination of the 8 zones supported by the NC300 System Zoning assignments are for use in controlling the patient staff and duty stations to which the master station may communicate andto which it may control system functions such as paging nurse follower and other programming functions Master stations will only communicate with stations for which they are zoned unless the PAGE button and the 09 key are pressed which will allow the user to page all zones in the system Master station zone assignments should be made in c
50. to initiate communica tion 26 IL421 Tek MICRO Nurse Call System Manual 4 1 6 4 1 7 4 1 8 TO REQUEST NURSE AIDE SERVICE 1 Select the room number as for communications 2 Press the NURSE green or AIDE yellow button The room number will flash in the NURSE or AIDE area on the screen depending on ser vice requested If desired communication may be established with the station to inform them assis tance has been requested 3 Press the RESET black button to cancel call This does not affect the nurse service request Nurse or aide service may also be requested when the call is initiated at the patient station This is accomplished as talk functions are initiated by pressing the NURSE or AIDE key as desired then pressing reset TO CANCEL NURSE OR AIDE SERVICE Repeatthe above procedure to cancel nurse or aide service request NOTE If the room number still appears in the call window it does not need to be selected again When a service request is made the system will continue visual signaling until a nurse or aide registers in the selected room When a nurse or aide registers by pressing the appropriate button on the room s SF350B Presence Station the room number will remain on steady in the NURSE or AIDE area When the nurse or aide leaves the room and presses the appropriate button on the Presence Station again the NURSE or AIDE registration is cance
51. to the room corresponding to the room number appearing in the call window If pre announce call tones are a one second tone will be heard at master and room station when TALK button is first pressed 2 To cancel press the RESET black button or hang up handset Medium High Priority and Per sonal Attention Calls must be reset at the point of origin 41 3 TO ANSWER CALL SELECTIVELY Enter the call number on the keypad followed by the 4 key The room number corresponding to the call number selected will appear in the call window If an incorrect call number is entered press RESET black button and try again 2 Press the TALK white button while speaking and release to listen If the handset is being used it is not necessary to press the TALK button while speaking The call tone will be silenced during communication If pre announce call tones are ON one second tone will be heard at master and room station when TALK button is first pressed 3 To cancel press the RESET black button or hang up handset Medium High Priority and Per sonal Attention Calls must be reset at the point of origin All calls may be answered in the same manner either automatically or selectively When a call is placed to the master station a tone signal will be heard and the call number room bed number and call type will be displayed High medium and low priority calls generate distinc
52. will default to physical port station is PRV Privacy set on or off connected to CODE 48 421 Tek MICRO Nurse Call System Manual Copyright TekTone Sound amp Signal Mfg Inc All Rights Reserved Port 4 Programming Sheet SPUA Default ASSIG BED ZONE NO PRIOR PAG PRV CODE LABEL RM BED ROOM R P PA ON OFF ON OFF ON OFF 1400 8400 1 1401 8401 1 1402 8402 1 1403 8403 1 1404 8404 1 1405 8405 1 1406 8406 1 1407 8407 1 1408 8408 1 1409 8409 1 1410 8410 1 1411 8411 1 1412 8412 1 1413 8413 1 1414 8414 1 1415 8415 1 1416 8416 1 1417 8417 1 1418 8418 1 1419 8419 1 1420 8420 1 1421 8421 1 1422 8422 1 1423 8423 1 1424 8424 1 1425 8425 1 1426 8426 1 1427 8427 1 1428 8428 1 1429 8429 1 1430 8430 1 1431 8431 1 Example of how information appears on View Station menu 1401 8401 1 1 2 3 R P ON OFF OFF SPUA System Port Unit Address PRIOR of station Routine or P Priority or PA Personal Attention ZONE NO Zone Station is programmed for System PAG Paging set on or off zone will default to physical port station is PRV Privacy set on or off connected to CODE On or off Copyright TekTone Sound amp Signal Mfg Inc All Rights Reserved ILA21 Tek MICRO Nurse Call
53. 00 CABLE CUT SHIELDS AND TAPE BACK DO NOT CONNECT TOGETHER IR300B SERIES STATION 8 PIN CONNECTOR SEE NOTE 2 MEL DATE 5 PAGE 12 23 98 NL410 subi 2 jeubis 9 punos euopyar 3ubu do 59 ENUEN 1545 ISMN amp O IOIIA2ISL SF332A SF341B e Gray PRESENCE STATION BATH EMERGENCY e Purple SF350B SF330 SF 337C SF 340B SF 333 Red e Blue Blue e Blue Blue DOME LIGHT CODE STATIONS LI380 Green e Green Green Green Green Yellow e Yellow Yellow e Yellow Yell ellow 2 e 4 Orange Orange White e Red Red Red Red Brown Brown Brown Brown IR300 Series Station 15 and 8 pin connectors P2 15 PIN Aide 115 Green White Nurse 14 Yellow White Bath Orange White r Emer Red White Emergency Emergency Monitor Brown White Monitor Monitor Code Black Code B White Negative Gray 12 VDC Purple 412 VDC 12 VDC i 12 VDC T Lamp Fault Blue Red Lamp 5 Green Green Lamp 4 Yellow Yellow Lamp Orange White Lamp Red LED Output Brown
54. 11B IR312B Stations with radio with PM311C PM312C SF311 call cord IR311B IR312B Stations SF311 10 call cord 10 IR311B IR312B Stations SF312 call cord dual IR311B IR312B Stations SF370 Series pillow speaker IR157N NC150N NC200N IR257 IR258 IR311 IR312 Stations 030 handset NC303 Master Stations 421 Tek MICRO Nurse Call System Manual 35 6 0 TEST INSTRUCTIONS The following section provides test instructions for determining correct system operation Stations should be checked one at a time Before proceeding with a system test all stations should be set to normal conditions as follows NC303 Master Station All function buttons should be in normal position no LED indication The call light should not be illuminated the beep tone switch should be positioned down DIP switch 8 IR301 B IR302B IR311B IR312B IR318 Patient Stations In sert the appropriate call cord in each call cord receptacle If the call placed light is flashing press the reset button to cancel it Station priority should be set for ROUTINE or PERSONAL ATTENTION IR310B Staff IR315B Duty Stations If the call placed light is flashing press the reset button to cancel it IR316 Psychiatric Station If the call placed light is flahsing turn the key to the OFF position and press the reset button SF336 SF338 Staff Emergency Psychiatric Station If the call placed light is flashing reset by turning the key on the IR316 to
55. 2B IR315B DUTY STATION HOOK UP FOR LI380 DOME LIGHT AND OR SINGLE CONTACT SMOKE DETECTOR SINGLE CONTACT SMOKE DETECTOR SEE NOTE 2 GREEN WHT AR AIDE NURSE YELLOW WHT BATH RANGE WHT INPUTS EMERG ED WHT FIRE MONITOR CODEA CODE B NEG 15 PIN CONNECTOR 11380 DOME LIGHT OUTPUTS YELLOW WHITE ADD JUMPER WIRE GRAY PURPLE 8 PIN BLUE CONNECTOR GREEN YELLOW GREEN GROUND WIRE ORANGE END 16 GAUGE GROUND WIRE TWO TWISTED PAIR SHIELDED 18 INDIVIDUAL SHIELDS SHIELDS MUST FEED THROUGH TO NEXT STATION ON LINE 4 COND 18 p SEN KA TO NEXT STATION ON LINE NOTES 1 INPUTS CODE A 6 CODE B ARE NOT AVAILABLE FOR IR315B STATIONS 2 FIRE INDICATION AT THE NURSE MASTER STATION IS SUPPLEMENTARY ONLY THE NC300 SYSTEM IS NOT INTENDED FOR USE AS A FIRE ALARM EVACUATION SYSTEM INPUTS EMERG AND MONITOR ARE NOT AVAILABLE WHEN A SINGLE CONTACT SMOKE DETECTOR IS IN USE TekTone TITLE LI380 DOME ZONE LIGHT WIRING MATL MEL DATE 12 23 98 SINGLE CONTACT SMOKE DETECTOR WIRING APP NC300 NURSE CALL SYSTEM REV 8 PAGE NL405 Copyright TekTone Sound amp Signal Mfg Inc All Rights Reserved IL421 Tek MICROS Nurse Call System Manual 57 NOTE ONLY NEEDED WHEN USING SUPERVISED CODE STATIONS SF332A SF341B AND SUPERVISED DOME LIGHTS 11384 ONLY ONE MASTER IS REQUIRED TO BE CONNECTED TO PK352 PER SYSTEM CABLE TO CPE DATA SHIEL
56. 3 0014 0015 0016 0017 0018 0019 0020 0021 0022 0023 0024 0025 0026 0027 0028 0029 0030 0031 0032 0033 0034 0035 0036 0037 DATE 12 18 12 18 12 18 12 18 12 18 12 18 12 18 12 18 12 18 12 18 12 18 12 18 12 18 12 18 12 18 12 18 12 18 12 18 12 18 12 18 12 18 12 18 12 18 12 18 12 18 12 18 12 18 12 18 12 18 12 18 12 18 12 18 12 18 12 18 12 18 12 18 12 18 12 18 TIME 10 50 52 10 50 52 10 50 52 10 51 52 10 51 31 10 51 31 10 52 51 10 53 51 10 54 41 10 55 51 10 56 11 10 57 51 10 58 11 10 59 51 11 00 51 11 01 51 11 09 41 11 12 51 11 22 11 11 23 51 11 23 59 11 25 23 11 26 23 11 27 51 11 32 23 11 56 56 11 58 58 12 12 12 12 23 11 12 34 51 12 35 31 12 40 51 10 54 41 10 55 51 10 56 11 10 57 51 10 58 11 10 59 51 STATION 55 1 1421 Tek MICRO Manual Supplement APPENDIX A EVENT PRINTING SAMPLE LABEL EVENT Menu Session Begin Room 8101 Station Deleted Menu Session End Menu Session Begin Room 8101 Station Added Menu Session End NORTH ROUTINE Call NORTH ROUTINE Reset NORTH STAFF Call NORTH STAFF Reset SOUTH DUTY Call SOUTH DUTY Reset EAST PRIORITY Call EAST PRIORITY Reset KITCH PER ATN Call KITCH PER ATN Reset WEST MONITOR Call WEST MONITOR Reset SOUTH EMER Call SOUTH EMER Reset EAST BATH Call EAST BATH Reset PSYCH FIRE Call PSYCH FIRE Reset ICU CODE Call ICU CODE Call ICU Nurse Requested ICU Nurse Reset THRPY Asst Requested THRPY Asst
57. 64 A Press blue button MAIN MENU Help Menu Master Assignments Menu User Function Menu System Function Menu Set Room Privacy Page Room Monitoring Radio Pager Menu exit select menu item Select Radio Pager Menu by pressing 7 on keypad This menu implements the four main pager capabilities C Select Program Pager Zone Assignments by pressing 2 on keypad PAGER ZONE ASSIGNMENTS Zoe 1 2 3 4 5 6 7 8 Pager No enter pager id Copyright TekTone Sound amp Signal Mfg Inc All Rights Reserved D Enter an assigned pager number and then press the key See VIEW PAGER ZONE ASSIGNMENTS for the current assigned page numbers The system default pager numbers are 400 447 Once the pager is located the following menu appears PAGER ZONE ASSIGNMENTS Zoe 1 2 3 4 5 6 7 8 Pager No 400 menu enter edit id E Press to accept the pager number displayed or enter another assigned pager number and then press the PAGER ZONE ASSIGNMENTS Zoe 1 2 3 4 5 6 7 8 X Pager No 400 menu 1 9 assign zones save Press numbers 1 8 to turn ON OFF Press key to save 3 23 VIEW RADIO PAGER ZONE ASSIGNMENTS Allows a full screen view of pager zone assignments and is useful for checking programmed information Rep
58. 8 and 9 not present on NC350C 64 A Press MENU blue button on NC303 Master Station MAIN MENU Help Menu Master Assignments Menu User Function Menu System Function Menu Set Room Privacy Page Room Monitoring Radio Pager Menu exit select menu item B Select System Function Menu by pressing 4 on keypad SYSTEM FUNCTIONS Set Time Date 12 24 Hour Clock Set Overtime Reconfiguration Hook Switch prev menu select menu item HO PWN Select Reconfiguration by pressing 4 on keypad RECONFIGURATION 1 Program Menu 2 Reinit System 3 Define Password 4 5 Set Reset Code Call Add Del Station prev menu select menu item D Select Program Menu by pressing 1 on keypad PROGRAM STATION Program Station Duty Station Call Display Duty Station DSN Zone Capture Program P ager prev menu select menu item E Select Program Station by pressing 1 on keypad STATION ZONE ASSIGNMENTS ZONE 2 3 5 6 8 menu enter enter room id Copyright TekTone Sound amp Signal Mfg Inc All Rights Reserved setting must now be entered e g 8100 8101 8200 8201 etc 7100 7101 7201 7202 etc when using NC350CP Series Thisis accomplished by entering the current station number Note The stations connected to each system should be programmed from that
59. ABLE Dig Out Dig In YELLOW WM300 Negative ORANGE 24 VDC RED 16 GAUGE BLACK CONNECTS TO GREEN GROUND ON STATION BROWN 8 PIN CONNECTOR TITLE WIRING DIAGRAM IR316 STATION APP NC300 NURSE CALL SYSTEM DATE PAGE 11 04 94 NL409 Tenue A urojs S esINN 29 subi v 2 jeubis 9 punos euopyar 3ubu do5 NC350C SERIES CPE PORT CABLES 1 4 AUDIO 1 GRAY GRAY OVERALL SHIELD DRAIN WIRES GRAY TO ADDITIONAL IR300B SERIES STATIONS AUDIO 6 1 PURPLE PURPLE DIG COMs GREEN GREEN DIG IN ORANGE ORANGE GREEN ORANGE YELLOW DIG OUT YELLOW 12 VDC 4 BLUE BLUE BLUE 24 VDC 7 BROWN T NEG 5 RED BROWN RED BROWN RED SYS GNDo Y CHASSIS GROUND t YELLOW t SHIELD DRAIN WIRES WM300 CABLE GROUND IN ACCORDANCE WITH NEC ARTICLE 250 amp 517 NOTES 1 Shields must be isolated from each other and continuous to splice point to the last station on the port 2 Shields must be isolated from each other and from any ground TITLE Connector Circuit Interconnections for Addressable Stations APP NC300 NURSE CALL SYSTEM WM3
60. C should not be exceeded IR310B Staff Station The staff station should be located where convenient for operation in areas such as utility and exam rooms kitchens or where staff members may need to originate calls or where cord sets are not required Do not locate a staff station in the same room with the NC303 Master Station The operating temperature range of 10 C 40 C should not be exceeded IL421 Tek MICRO Nurse Call System Manual 5 IR315B Duty Station The duty station should be located where convenient for operation in areas such as utility and exam rooms or where a nurse may perform a function out of hearing or sight range of the NC303 Master Station The operating temperature range of 10 C 40 C should not be exceeded IR316 Psychiatric Station The IR316 is designed for use in psychiatric wards or other high security hospital areas and is normally flush mounted at the entrance to these areas LI380 LI384A LI386 Dome Lights The dome light should be located in the corridor above or beside the door of the associated room Location should provide unobstructed visibility of the corridor light in both directions When used as a zone light locate the LI380 LI384A LI386 in the corridor area nearest the nurses central monitoring station Location should provide unobstructed visibility of each corridor zone light from the central location When the LI380 Dome Light is used with an IR station install jump
61. CTOR TO SYSTEM COMMON WIRES GREEN BLUE PURPLE GRAY TV AUDIO amp SWITCH COMMON RED TV AUDIO FROM TV OUTLET ORANGE TV SWITCH OUTPUT CONNECTS TO BROWN WITH BUTTON DEPRESSED COMMON AUDIO O GREEN RADIO OUTPUT TO RY350 BLUE Hi VIOLET NOT USED BED 1 7 PIN CONNECTOR NOTE PM321B lamp does not include top 7 pin module TITLE WIRING DIAGRAM PM321B PM322B MATL MEL 11 04 94 Nm LAMP MODULE APP NC300 NURSE CALL SYSTEM REV 3 22 412 64 1421 Tek MICRO Nurse Call System Manual Copyright TekTone Sound amp Signal Mfg Inc All Rights Reserved EIVIN 39 86 82 87 lt S a gt 5 x gISEJd WOLIOHNNOO OVA SIT INSAISQfGV 95 YOLOANNOO Nid 1 NOLOSNNOO ATdd S 04 x COLLA 81663410 doy 8 ILYN WALSAS TIVO 45 OOEDN DOSEDN LNOAVT 3GISNI A ddns samod 3noqe uoneunojul 10 19 10 gISEJd OVA STT ONISNOH NVA iddV yod preg 1104 gC0 ON dij WAAN Joduny oras Koy piv ssng ASSEON T8 p 8194 AAYO 1404 425608 2 5104 quvo 1404 AZSEON QAVO ANIT 9860 Tonuo 55V 191581 QAYI
62. DIO PAGER ZONE ASSIGNMENTS 21 3 24 PROGRAM RADIO PAGER CALL ASSIGNMENTS 21 3 25 TURN RADIO PAGER ON OFF 3 26 ASSIGN PAGER ROOM V aiio yeee aA Oeae E i UXOR ree e Yee pec redet Eb peine EXECUTE A PAGE eed e EUR Re RERO e URS EE 4 1 NC303 MASTER STATION NC310B VIDEO MONITOR 2 41 2 TO ANSWER A CALL AUTOMATICALLY 25 4 1 3 TO ANSWER CALL SELECTIVELY toten inita inito totns tete ante tainen on 25 4 1 4 TO PLACE A CALL 4 1 5 TO PLACE CALL ANOTHER MASTER 8 22202 2 2 4440000 0 000000 26 4 1 6 REQUEST NURSE AIDE SERVICE 2 402444 05 101010 00000000000000000 26 4 1 7 TO CANCEL NURSE AIDE SERVICE 26 4 1 8 REQUEST STAT SERVICE 26 4 1 9 TO CANCEL STAT SERVICE REQUEST 4 1210 TO PAGE A iter t e IR t WR REIHE EU e PIRE HR Ete AREE ER eMe 4 1 11 TO PAGE A ZONE ACROSS DSN 4 1 12 TO PAGE ALL ASSIGNED ZONES 4 4 1 13 TO PAGE ALL STATIONS ON SYSTEM 27 41 14 NURSE AIDE PAGING eerte 27 4 1 15 ENABLE R
63. DS AUDIO SHIELDS GRAY AUDIO PURPLE ALL CALL ORANGE DIG IN YELLOW DIG OUT BROWN TALK RED NOT USED GREEN DIG COM BLUE 412 VDC CABLE TO MASTER BAT 1 DATA SHIELDS AUDIO SHIELDS GRAY AUDIO PURPLE ALL CALL ORANGE DIG IN YELLOW DIG OUT BROWN TALK RED NOT USED GREEN DIG COM BLUE 12 VDC ENCLOSURE FOR PK352 BAT 2 42vpc3 4 D 55106 q 5 16 VAC 6 TRANSFORMER 110 VAC 12 BATTERY 1 5 AH PK352 HOUSING Equipment Location Locate with NC350C CPE TekTone TITLE WIRING DIAGRAM PK352 Battery Charger 55106 Transformer lt Battery 12v 1 5aH 110 VAC Connection DATE 03 17 99 PK352 BATTERY CHARGER APP NC300 NURSE CALL SYSTEM PAGE NL406 58 ILA21 Tek MICRO Nurse Call System Manual Copyright TekTone Sound amp Signal Mfg Inc All Rights Reserved jeubis 9 punos euopyar o 3ubuAdo peuesauy siu DUI 6S enue urojsS ISINN gOSIOTIA2ISL To 70 volt output power amplifiers Green White Brown Yellow White Channel 1 Red Orange White SF301PIR Red White Pillow Yellow Brown White Black Speaker r Green White Blue Gray Red Brown Not Used Not Used Channel 2 Channel 3 Channel 4
64. DURE 6 2 NC303 MASTER STATION NC310B VIDEO MONITOR TEST 2 0 6 3 SE336 SF338 STAFF EMERGENCY IR316 PSYCHIATRIC IRO19C SPEAKER MIC TEST PROCEDURE 3 6 4 SE340B SF337C BATH EMERGENCY STATION TEST PROCEDURE 6 5 SF341B CODE STATION TEST PROCEDURE cccccscssseccssssssesosescsssssscscsssscnesssavscsssssseseseessssssssesssassosesssesasessasenssaseosonas 6 6 SF350B NURSE AIDE PRESENCE STATION TEST PROCEDURE E 6 7 PRIORITY CALLS TEST PROCEDURES ceti pret biete br e d bd e d da p i D ete dig PROGRAMMING SHEETS NR arose epa eR RU RR A a ee PORT 2 PROGRAMMING SHEET PORT 3 PROGRAMMING SHEE T one eo oet nd iege UR OPE p ee e PED eiie etie PORT 4 PROGRAMMING SHEP Tirrena homer d d e OE ER HIER EHE HERE WIRING DIAGRAMS IR300B SERIES CONNECTIONS TO PERIPHERAL DEVICES SUPERVISED DOME LIGHT NL401 53 BLOCK WIRING DIAGRAM NL402 222 22222224242 2 0 200 00011 01000000 54 NC350C WIRING DIAGRAM USING INDIVIDUAL CABLES 403 99 DUAL SYSTEM NETWORK WIRING SPECIFICATIONS NL404 256 14380 DOME ZONE LIGHT WIRING NL405 2 57 PK352 BATTERY CHARGER WIRING DIAGRAM NL406 2 58 RY350B WIRING DIAGRAM 407 2 59 6 amp 7 PIN CONNECTOR OUTPUTS FOR IR300A B IR311A B amp IR312A B 408
65. E A CALL 1 Presscallbuttonlocated on end of call cord or press red call button indicated by nurse symbol on pillow speaker or pull call cord on IR318 depending upon type of station used until the call placed light flashes A call will automatically be placed if call cord or pillow speaker is pulled from its receptacle B TO REPLY TO A CALL 1 Reply in a normal voice when spoken to NOTE For IR311B or IR312B Patient Stations utilizing PM311C or PM312C Pillow Speaker modules and SF301PI Series Pillow Speaker communication with the master station will be heard through the pillow speaker If the pillow speaker is removed from its receptacle during communication press RESET black button then TALK white button and the audio will be transferred to the station speaker C TO CANCEL A CALL 1 Press the reset button until the call placed light is extinguished Calls from emergency type stations associated with the patient station must be canceled at the point of origin 2 To cancel a call resulting from the removal of the call cord or pillow speaker replace the jack in the receptacle D TOSELECT TELEVISION CHANNELS 1 For models IR311B IR312B only when used with SF301P Series Pillow Speaker press button indi cated If TV is off pressing this button will turn it on Continue pressing until desired channel is reached TV is turned off when channel OFF on TV is selected Volume control adjusts TV volum
66. E LIGHT DOME LIGHT DOME LIGHT DOME LIGHT C e gt FOR LI380 FOR LI384A LI380 OR LI384A DOME LIGHT FOR LI380 FOR LI384A A4C FOR 11380 AZ FOR LI384A FOR LI380 FOR LI384A FOR LI380 FOR LI384A 4 D IR300B MULTI STATION IR301B SINGLE STATION IR302B DUAL STATION IR311B SINGLE STATION IR310B STAFF STATION IR312B DUAL STATION NC350C SERIES CONTROL AND POWER SUPPLY IR315B DUTY STATION A42 COND 322 A PK352 P BATTERY CHARGER SF330 SF333 SF337C SF340B BATH STATION SF330 SF333 SF337C SF340B BATH STATION SF332A SF341B CODE CALL STATION SF330 SF 333 SF337C SF340B BATH STATION SF330 SF 333 SF337C SF340B BATH STATION A SF330 SF333 SF332A SF337C SF340B sr341B BATH CODE STATION STATION SF331A SF340B EMERG STATION A COND 22 A SF330 SF 333 subi 2 5 9 punos euopyar 6 SF350B PRESENCE STATION ELECTRICAL RATINGS MAX NC350C SERIES CPE 120 VAC 4AMPS NC310B MONITOR 120 VAC 5 AMPS NC303 MASTER 12 VDC 300 mA IR300B IR301B IR302B IR310B IR311B IR312B IR315B PATIENT DUTY STAFF STATIONS 24 VDC 250 mA SF330 SF331 SF332A SF333 SF337C SF340B SF341B SF332A SF341B CODE STATION A SF330 SF 333 SF337C SF340B BATH STATION SF350B BATH CODE EMERGENCY PRE
67. ICROPHONE Fig 12 CALL CORD RECEPTACLE ekTone RESET SWITCH CALL PLACED IN USE LIGHT LIGHT IR311B SINGLE PATIENT STATION SPEAKER MICROPHONE Fig 13 TekTone o RECEPTACLE CALL CORD RESET SWITCH CALL PLACED IN USE LIGHT LIGHT Copyright TekTone Sound amp Signal Mfg Inc All Rights Reserved IR312B DUAL PATIENT STATION SPEAKER MICROPHONE Fig 14 CALL CORD RECEPTACLE TekTone RESET SWITCH CALL PLACED IN USE LIGHT LIGHT IR318 SINGLE PATIENT STATION SPEAKER MICROPHONE Fig 15 CALL PLACED LIGHT RESET SWITCH IN USE LIGHT CALL CORD ILA21 Tek MICRO Nurse Call System Manual 29 Call Cord Receptacle There are two kinds of call cord recep tacles The rectangular type found on the IR311B IR312B Stations is for use with a pillow speaker or SF311 SF312 Call Cords The round type found on the IR301B IR302B stations is for use with a call cord SF301 SF302 Single bed stations IR301B IR311B have one call cord receptacle dual bed sta tions IR302B IR312B have two Refer to Fig 16 and Fig 17 for locations names and functions of controls and indicators Speaker Microphone The speaker microphone is used for voice communications and tone signaling Due to the high sensitivity of the microphone it is not necessary for the patient to move close to the unit or to raise the voice above normal speaking level to be heard OPERATION A TOPLAC
68. IL421 Tek MICRO Nurse Call System Manual Copyright TekTone Sound amp Signal Mfg Inc All Rights Reserved C An X will appear for the zone indicating what DSN zones in use Press number 1 8 to remove Pressing the same number again will cause the to reappear Press 9 on keypad to set all zones ON Press 0 on keypad to set all zones OFF MENU appears in Master call window during menu session 3 10 ADDING OR REMOVING MASTER STATIONS As long as the master stations remain in ascending order they can be added or deleted by doing the following Note On Main Menu numbers 8 and 9 used on NC350CP Series 8 and 9 not present on NC350C 64 A Turn the system off B Place master stations in the new ports a Must start in port 1 b Ports must be consecutively filled The zone assignments and hook switch information will be retained by each port even when master is removed 3 11 SET 12 OR 24 HOUR CLOCK FORMAT After initial system power up the time of day will be displayed in 12 hour format To change clock format fol low the procedure listed below Note On Main Menu numbers 8 and 9 used on NC350CP Series 8 and 9 not present on NC350C 64 A Press MENU blue button MAIN MENU Help Menu Master Assignments Menu User Function Menu System Function Menu Set Room Privacy Page Room Monitoring Radio Pa
69. N STATUS NC350CP SERIES 2 Master Assignments Menu 3 User Function Menu 4 System Function Menu Follow the procedure listed below to display or change the 5 Set Room Privacy Page 6 Monitoring DSN Status You must have two systems connected to 7 Radio Pager Menus gether via NC353BDSN Link Card exit select menu item B Select Master Assignments Menu by pressing 2 on A Press MENU blue button keypad MAIN MENU 1 Help Menu MASTER ASSIGNMENTS 2 Master Assignments Menu 1 Master Call Display 3 User Function Menu 2 Intercom Preannounce Tones 4 System Function Menu prev menu select menu item 5 Set Room Privacy Page 6 Room Monitoring 7 Radio Pager Menu C Select Master Call Display by pressing 1 on key 8 Dual System Status ad 9 Dual System Zone Capture pad exit select menu item MASTER CALL DISPLAY um eodd SON Priority SON B Select Dual System Status by pressing 8 on Fire ON Duty ON keypad Emergency ON Staff ON Monitor ON Pers Attn ON Bath ON Routine ON DUAL SYSTEM STATUS Cord Out ON Stat ON Status Master menu down 0 up 1 on off save 1 toggle status Press 1 on keypad to turn ON OFF Press key until To set DSN Status one system must be set up as a prompted to save slave and one system as a master If DSN is not used DSN status must be set to NOT ACTIVE Default
70. NFPA 470 1987 NC350C 64 NC350CP Series Central Processing Equipment CPE The CPE should be located in an accessible area near a dedicated AC outlet preferably central to the associated master stations For optimum operation the CPE should be located in an area with an operating temperature of approxi mately 26 C 70 80 relative humidity Equipment should be accessible to a good earth or cold water pipe ground using a minimum 16 gauge wire Location should have convenient Copyright TekTone Sound amp Signal Mfg Inc All Rights Reserved cable runs to the master and patient stations The CPE may be surface or desk mounted in a minimal amount of space Optional battery backup should be located with the CPE Printer The printer may be located where convenient but no further than 100 from the CPE NC303 Master Station The NC303 Master Station s should be located within easy reach of operating personnel on a desk or counter top The master station is provided with 6 of cable with a D subminiature connector for wire termination The master station should be located within easy reach of the wall plate supplied by TekTone for cable termination Locate the wall plate on a single gang ring or box The operating temperature range of 10 C 30 C should not be exceeded NC310B Video Monitor The NC310B Video Monitor s should be located with the NC303 Master Station where light levels do not affect legibility of the
71. ON SYSTEM 16 Gauge Ground Wire Common Cable WM300 To NC300 CPE NC300 WIRING DIAGRAM DATE 03 17 99 LI386 DOME ZONE LIGHT SEE NL402 FOR WIRE SPECS PAGE NL415 urojs S esINN eOUOIN AL 89 subi v euiS 9 punos euopyar 1ubu do LI384A Gray Purple Blue Green Yellow To additional IR300 ES series Stations 4 Orange Red 18300 Series Stations 15 and 8 pin connectors Aide Nurse Bath Emer Fire Monitor Code A Code B Negative 12 VDC Lamp Fault Red Lamp Green Lamp Yellow Lamp White Lamp LED Output Audio Audio 12VDC Data Com Data Out Data In Negative 24VDC 16 gauge Ground Wire P2 15 PIN 15 e 14 Yellow White 13 Orange White 12 Red White 11 Brown White 10 Black White Gra Purple Blue Green Yellow Orange Red IS 4 Joo Brown 8 PIN Gray Purple Blue Green Yellow Orange Red ein Jas o N Joo 000900 Common Cable WM300 To NC300 CPE TekTone TITLE APP 1R300 Series Stations 15 and 8 pin connectors Aide Nurse Bath Emer Fire Monitor
72. OOM MONITORING 2 2 4022 2 202 1130000000000500000050000050 0000000 27 4 1 16 TO USE NURSE AIDE FOLLOWER 28 4 1 17 PAGE UP DOWN FEATURE 4 1 18 TO OPERATE RADIO PAGER cccesessssossseseescssstensnssassosonascenesensnsoseseecengnavenseassavaenensseenonenassoussennenosascosonsvaveesoess 4 2 IR301B IR302B IR311B IR312B IR318 PATIENT STATIONS 4 3 IR310B STAFF IR315B DUTY STATIONS 4 4 18316 PSYCHIATRIC STATION 4 5 SF341B CODE CALL STATION 2 4 6 SF336 SF338 STAFF EMERGENCY PSYCHIATRIC 5 8 0 4 7 SF350B NURSE AIDE PRESENCE STATION 4 8 SF337C PULL PULL CORD SHOWER EMERGENCY CALL STATION s 4 9 SF340B PULL PULL CORD EMERGENCY CALL 5 2 4 10 LI380 LI384A LI386 DOME ZONE LIGHTS 6 0 TABLE OF CONTENTS cont 5 0 SYSTEM MAINTENANCE INSTRUCTIONS 00 000000 sees eese esent tasas tasas 35 5 1 NC303 MASTER STATION in OD 5 2 IR301B IR302B PATIENT STATIONS 35 5 3 IR311B IR312B PATIENT STATIONS 35 5 4 143801 84 1386 DOME ZONE LIGHTS 35 5 5 REPLACEMENT PARTS e ineo nni bir ibo nibo epe dn pete ebd 35 TEST INSTRUCTIONS me 6 1 IR301B IR302B IR310B IR311B IR312B IR318 PATIENT STAFF STATION TEST PROCE
73. OR IR311A IR312A STATION Blue Green Yellow Orange Red Brown TITLE 6 amp 7 PIN CONNECTOR OUTPUTS FOR IR300A B IR311A B AND IR312A B APP NC300 NURSE CALL SYSTEM CALL LED OUTPUT CONTROL PM311C PM312C ONLY CALL INPUT 12 VDC RADIO OUT 12 VDC TV ON OFF SWITCH TV AUDIO TV COMMON CALL LED INPUT CONTROL PM311C PM312C ONLY RADIO OUTPUT 12 VDC TV ON OFF SWITCH TV AUDIO TV COMMON 11 03 94 NL408 jeubis 9 punos euopyar o 3ubu do peuesauy siu DUI 19 urojsAS ISINN sOSIOTIAI2ISL ZVI YELLOW IRO19C 5 COND 222 2 COND 22 SHIELDED lt IR316 STATION WIRE PIGTAILS FROM IR316 PC BOARD 4 WHITE YELLOW Z O SF336 BLUE GREEN YELLOW ORANGE RED BROWN BLACK WHITE GRAY PURPLE 4 COND 22 BLUE GREEN RED BROWN SHIELDS CONNECT TOGETHER FOR EACH PAIR BUT NOT CONNECTED TO OTHER SHIELDS IN CABLE OVER ALL SHIELDS Audio YELLOW ORANGE GREEN WHT KEY SWITCH YELLOW WHT ORANGE WHT RED WHT BROWN WHT 15 PIN CONNECTOR NOTE J ADDED TO DISABLE LAMP FAULT INPUT GRAY CONNECT TOGETHER Audio PURPLE 12 VDC BLUE Dig Com GREEN NC300 C
74. ORITY MENU FIGURE 19 PROGRAM PATIENT PRIVACY PAGE MENU FIGURE 20 CHANGE MASTER OR STATION ZONE MENU FIGURE 21 CALL ANOTHER MASTER MENU FIGURE 22 TROUBLE SHOOTING GUIDE entente 54 4 1 CODE FAULT 4 2 COMM FAULT 4 3 DATA POLLING NOISE 44 DUTY STATION IR315B 4 5 LAMP FAULT 4 6 MASTER FAULT 4 7 VIDEO DISPLAY 1 0 Software Enhancements Main Menu Figure 1 Main Menu Help Menu Master Assignments Menu User Function Menu System Function Menu Set Room Privacy Page Room Monitoring Radio Paging Menu Dual System Status Dual System Zone Capture B GJ NJ r3 exit select menu item Note Items 8 and 9 are available on 4 06 and 3 06 They are not available on 1 96 Select System Function Menu by pressing 4 on keypad Access to this menu is password protected if a password is in effect System Function Menu Figure 2 System Functions Set Time Date 12 24 Hour Clock Set Overtime Reconfiguration Hook S witch prev menu select menu item Select Reconfiguration Menu by pressing 4 on the keypad Access to this menu is password protected if a password is in effect As you will notice options 0 and 7 are new selections that have been added to this menu that includes adding and deleting stations Reconfiguration Menu Figure 3 Reconfiguration Program Menu Reinit System
75. PRIOR PAG PRV CODE LABEL RM BED ROOM R P PA ON OFF ON OFF ON OFF 1132 8132 1 1133 8133 1 1134 8134 1 1135 8135 1 1136 8136 1 1137 8137 1 1138 8138 1 1139 8139 1 1140 8140 1 1141 8141 1 1142 8142 1 1143 8143 1 1144 8144 1 1145 8145 1 1146 8146 1 1147 8147 1 1148 8148 1 1149 8149 1 1150 8150 1 1151 8151 1 1152 8152 1 1153 8153 1 1154 8154 1 1155 8155 1 1156 8156 1 1157 8157 1 1158 8158 1 1159 8159 1 1160 8160 1 1161 8161 1 1162 8162 1 1163 8163 1 Example of how information appears on View Station menu 1132 8132 1 1 2 3 ON OFF OFF SPUA System Port Unit Address PRIOR of station R Routine or i a 3 Priority or PA Personal Attention ZONE NO Zone Station is programmed for System PAG Paging set on or off zone will default to physical port station is PRV Privacy set on or off connected to CODE Onoroff 44 421 Tek MICRO Nurse Call System Manual Copyright TekTone Sound amp Signal Mfg Inc All Rights Reserved Port 2 Programming Sheet SPUA Default ASSIG BED ZONE NO PRIOR PAG PRV CODE LABEL RM BED ROOM R P PA ON OFF ON OFF ON OFF 1200 8200 1 1201 8201 1 1202 8202 1 1203 8203 1 1204 8204 1 1205 8205 1 1206 8206
76. RESET 2 4 8402 Jo S 08 09 19 12 30 27 8402 NURSE IN E 09 09 19 12 30 27 8402 NURSE OUT T 9 10 09 19 12 30 43 8406 CODE CALL CALL 11 09 19 12 30 48 8406 CODE CALL RESET 4 lo o 0 NN Copyright TekTone Sound 6 Signal Mfg Inc All Rights Reserved NC350CP Series Central Processing Equipment CPE The NC350CP Series CPE provides the same technology as the NC350C 64 except it provides for printer capability and is capable of interfacing with another NC350CP Series serial interface DSN Dual System Networking The NC350C 64P provides for up to 64 addresses NC350C128P up to 128 addresses and the NC350CPX2 for up to 256 addresses The NC350CP Series also provides a means of communicating the same event information about its particular system to other intelligent systems such as pocket paging and management monitoring computer systems via standard 9600 baud serial communications port NC350C 64 with NC362UP will pro vide the same serial port as does the NC350CP Series NC303 Master Station The NC303 Master Station utilizes microprocessor technology to control all the communications and programming functions provided by the NC300 Nurse Call System and to monitor fault conditions within the system The nurse master station consists of handset audible signal control switches call light speaker microphone function buttons some with LED s 12 button digital keypad CPE fa
77. SENCE STATIONS 12 VDC 30 mA LI380 L384A DOME LIGHTS 24 VDC 200 mA LI386 DOME ZONE LIGHT 24 VDC 250 mA SF301PIR PILLOW SPEAKER 12 VDC 50 mA PK352 BATTERY CHARGER 24 VAC 1 25 AMP SF337C SF340B BATH STATION NC303 MASTER STATION NC310B VIDEO MONITOR SF330 SF 333 SF337C SF340B BATH STATION SF330 SF 333 SF337C SF340B BATH STATION CABLE LEGEND 5 COND 22 6 COND 22 1 PAIR SHIELDED 18 PLUS 1 PAIR SHIELDED 18 INDIVIDU ALLY J ACKETED PLUS 4 COND 18 PLUS 1 COND 16 ALL WIRES STRANDED D RG59U COPPER BRAID COAXIALCABLE OR WM300 CABLE Nine conductor cable assembly protected by a Gray PVC 045 thick jacket Nominal O D 590 Configured as follows Data Assembly consists of 1 twisted pair plus 1 conductor 18 gauge stranded wire wrapped by an overall aluminum mylar shield and an Orange PVC 020 thick jacket The shield has a 18 gauge drain wire The conductors are Yellow Orange and Green insulated by 033 thick Tapolene The capacitance between these conductors is 12 5 pF foot Audio Assembly consists of 1 twisted pair 18 gauge stranded wire wrapped by an overall aluminum mylar shield and a Gray PVC 020 thick jacket The shield has a 18 gauge drain wire The conductors are Purple and Gray insulated by 015 thick PVC Three 18 gauge stranded wires wrapped by an overall aluminum mylar shield The shield has a 18 gauge drain wire The conductors are Red Brown and
78. System Manual 49 Port 4 Programming Sheet SPUA Default ASSIG BED ZONE NO PRIOR PAG PRV CODE LABEL RM BED ROOM R P PA ON OFF ON OFF ON OFF 1432 8432 1 1433 8433 1 1434 8434 1 1435 8435 1 1436 8436 1 1437 8437 1 1438 8438 1 1439 8439 1 1440 8440 1 1441 8441 1 1442 8442 1 1443 8443 1 1444 8444 1 1445 8445 1 1446 8446 1 1447 8447 1 1448 8448 1 1449 8449 1 1450 8450 1 1451 8451 1 1452 8452 1 1453 8453 1 1454 8454 1 1455 8455 1 1456 8456 1 1457 8457 1 1458 8458 1 1459 8459 1 1460 8460 1 1461 8461 1 1462 8462 1 1463 8463 1 Example of how information appears on View Station menu 1432 8432 1 1 2 3 R P ON OFF OFF SPUA System Port Unit Address PRIOR of station Routine or oe 3 Priority or PA Personal Attention ZONE NO Zone Station is programmed for System PAG Paging set on or off zone will default to physical port station is PRV Privacy set on or off connected to CODE 50 IL421 Tek MICRO Nurse Call System Manual Copyright TekTone Sound amp Signal Mfg Inc All Rights Reserved SOUND amp SIGNAL Tek MICRO NC300 Microprocessor Nurse Call System Wiring Diagrams Copyright TekTone Sound amp Signal Mfg Inc All Rights Reserved IL421 Tek MICRO Nurs
79. ation DSN Zone Capture by pressing Cord Out Nurse E Priority Aide 3 on keypad Duty Station No Duty Station DSN Zone Assignments menu enter enter room id Zone 1 2 3 4 5 6 7 8 X X X X X X X X Enter the current Duty Station using the keypad Note Default programming is all call responses menu enter room id Enter the current Duty Station using the keypad An X will appear for the zone indicating what DSN zones are in use Press number 1 8 to remove Pressing the same number again will cause X to reappear Press 9 on keypad to set all zones Press 0 on keypad to set all zones OFF MENU appears in Master call window during menu session 14 L421 Tek MICRO Nurse Call System Manual Copyright TekTone Sound amp Signal Mfg Inc All Rights Reserved 3 4 ADD DELETE STATION Note On Main Menu numbers 8 and 9 used NC350CP Series 8 and 9 not present on NC350C 64 Press the MENU blue button MAIN MENU Help Menu Master Assignments Menu User Function Menu System Function Menu Set Room Privacy Page Room Monitoring Radio Pager Menu exit select menu item B Select System Function Menu by pressing 4 on keypad SYSTEM FUNCTIONS Set Time Date 12 24 Hour Clock Set Overtime Reconfiguration Hook Switch prev
80. atus menu enter enter room id E Enter room number and bed number SET RESET CODE CALL Room No 8108 1 Code Call Status ON menu save 1 on off Press 1 to turn ON OFF Press to save 3 16 REINITIALIZE SYSTEM System reinitialization is only necessary when system requires default programming for all devices Reinitialization removes all previously programmed sys tem configurations except password including room numbers zoning privacy etc and should not be used unless absolutely necessary If the system must be reinitial ized follow the procedure listed below Note On Main Menu numbers 8 and 9 used on NC350CP Series 8 and 9 not present on NC350C 64 A Press MENU blue button MAIN MENU Help Menu Master Assignments Menu User Function Menu System Function Menu SetRoom Privacy Page Room Monitoring Radio Pager Menu exit select menu item NW OURWNeE B Select System Function Menu by pressing 4 on keypad SYSTEM FUNCTIONS Set Time Date 12 24 Hour Clock Set Overtime Reconfiguration Hook S witch prev menu select menu item HO Select Reconfiguration by pressing 4 on keypad RECONFIGURATION 1 Program Menu 2 Reinit System 3 Define Password 4 Set Reset Code Call 5 Add Del Station prev menu select menu item
81. blinking 4 Allsignals and tones should be repaired when the bulb is replaced Follow the same sequence as above for CODE FAULT and CORD OUT Initiate a call from each of the following types of stations one at a time Duty Station Staff Station Code Station Bath Station Emergency Station Fire Station Do due O Copyright TekTone Sound amp Signal Mfg Inc All Rights Reserved Monitor Station Priority Station Personal Attention Station 0 Routine Station oe After initiating each call delete that station before reset ting the call All calls and signals should disappear Testing for an Added Station Add each station deleted from the section above one at atime Check to see that all tones and signals associated with that station are restored For example for aroutine station check for the following 1 Call placed light should be flashing at the patient station 2 Dome light white lamp should be on and steady 3 Call light at master station should slowly flash 4 A tone should signal every 8 seconds at master station 5 Call information should appear on the call screen with call priority 6 2 NC303 MASTER STATION NC310B VIDEO MONITOR TEST PROCEDURE A Initiate a call from each master station to a patient station as described in the System Operating Section 4 0 page 23 Check for following at master station 1 Call number room bed ID number call type ap pear on
82. button cancels a call to the master station and cancels the yellow in use light on the panel Key Switch The centrally located key switch is used to place and reset placed calls The key switch does not deactivate the speaker microphone IRO19C station Call Placed Light The yellow LED flashes to indicate call placement ram KEY SWITCH ON OFF RESET CALL RESET SWITCH IN USE LIGHT CALL PLACED LIGHT Fig 20 OPERATION TO PLACE CALL 1 Place the key in the key switch and turn to the on position the call light will illuminate B TO CANCEL A CALL Turnthe key to the off position and press the reset switch 4 5 SE341B CODE CALL STATION Refer to Fig 21 for locations names and functions of controls and indicators Refer to NL401 NL405 and NL415 for wiring outputs provided for dome light indication A brief description of the operating controls for the SF341B follows Pull Down Reset Lever The Pull Down reset lever is used to place and reset code priority calls Call Placed Light The red LED flashes to indicate call place ment 32 IL421 Tek MICRO Nurse Call System Manual Call Placed Light Code Pull Down Reset Lever Guide Tab Call Cord Field Installation option refer to Sec 2 2 OPERATION A TOPLACE A CALL 1 Pullonthe blue lever or pull down on the 7 nylon cord attached B TO
83. ce the rate of medium priority calls and a fast repeating tone is heard from the speaker System Stat Priority The emergency light and call placed light alternately flash and a fast repeating tone is heard from the speaker Speaker Microphone The speaker microphone is used for voice communications and tone signaling Due to the high sensitivity of the microphone it is not necessary to raise the voice above normal speaking level to be heard OPERATION A TOPLACE A CALL 1 Press the call button until the call placed light flashes TO REPLY 1 Reply in a normal voice when spoken to C TO CANCEL A CALL 1 Press the reset button until the call placed light is extinguished Calls from emergency type stations associated with the staff or duty station must be canceled at the point of origin IR315B DUTY STATION code stations cannot be wired to duty stations SPEAKER MICROPHONE CALL BUTTON CALL PLACED LIGHT RESET EMERG CALL o RESET SWITCH EMERGENCY IN USE LIGHT LIGHT Fig 19 IL421 Tek MICRO Nurse Call System Manual 31 4 4 IR316 PSYCHIATRIC STATION Refer to Fig 20 for locations names and functions of controls and indicators Refer to WIRING DIAGRAMS NL401 NL405 and NL415 for wiring outputs provided for dome light indica tion A brief description of the operating controls for the IR316 follows Reset Switch In Use Light The reset
84. e pillow speakers with a RADIO button The pillow speaker must be plugged into a TekTone IR311B IR312B Patient Station One relay is required per bed The six position continu ous operation device allows for the selection of up to four radio channels TV and OFF The pillow speaker features simple push button radio and TV controls All RY350B components are mounted on a ABS plastic panel The RY350B requires a separate DC power source 12VDC 1 2 W Call Cords SF301 Push button call cord use with IR301B IR302B SF301P Series Pillow speaker use with IR311B IR312B SF301PI Series Pillow speaker with intercom use with IR311B PM311C and IR312B PM312C combinations SF302 Dual push button call cord IR301B IR302B SF301 10 Push button call cord w 10 IR301B IR302B SF302 10 Dual push button call cord w 10 cord use with IR301B IR302B SE311 Push button call cord w modular jack IR311B IR312B SE312 Dual push button call cord w modular jack IR311B IR312B SF370 Series Pillow speaker use with IR157N NC150N NC200N IR257 IR258 IR311 IR312 Geriatric call cords available with 1 4 phone jack modu lar jack single and dual Contact factory for details Note 2 22 EQUIPMENT LOCATION Locate NC300 System Equipment in accordance with the fol lowing information The installation of all system equipment must meet the requirements of the National Electrical Code ANSI
85. e Reconfiguration Hook Switch prev menu select menu item Select Reconfiguration by pressing 4 keypad RECONFIGURATION Program Menu Reinit System Define Password Set Reset Code Call Add Del Station prev menu select menu item Ui OU N IH 18 IL421 Tek MICRO Nurse Call System Manual D Select Define Password by pressing 3 on keypad DEFINE PASSWORD Enter 6 digit Password Password menu none 0 9 password Enter desired password 0 9 must be six digits on keypad Password will not appear Enter password again to verify If password was entered correctly menu will disappear and operator will be prompted with Password Protection Menu PASSWORD PROTECTION OFF Master Assignments Menu ON User Function Menu OFF System Function Menu OFF Set Room Priority Privacy Page OFF Room Monitoring OFF Radio Pager Menu OFF Dual System Status OFF Dual System Zone Capture down 0 up 1 toggle Set desired password protection to customize password requirements to any level menu Default is all levels OFF Press 1 on keyboard to turn ON OFF Password must now be used to access customized password level selections and system reinitialization To enter a new password or to cancel the password requirement repeat steps through and enter the current password Repeat
86. e Red Lamp Green Green Lamp Yellow Yellow Lamp Orange White Lamp Red LED Output Brown NOTE Both jumpers on back of station need to be in down position Emergency Emergency Smoke Detector Contacts Normally Open Audio Stay ve Purple Audio Optional Method Monitor Contact Normally Open Blue 12 VDC for Monitor Contact Green Note Use only if Data Com Emergency Input is Data Out Yellow not used Data In Negative 24 VDC Note Use only if both Emergency Orange and Monitor Inputs are used Red NOTE FIRE INDICATION AT THE NURSE MASTER IS SUPPLEMENTARY ONLY THE NC300 SYSTEM IS NOT INTENDED FOR USE AS A FIRE ALARM EVACUATION SYSTEM 16 Gauge Ground Wire NOTE IR315B does not support CODE BLUE Stations Common Cable WM300 To NC300 CPE TITLE NC300 WIRING DIAGRAM APP IR300B Series Connections see NL402 for wire specifications to peripheral devices supervised dome light MATL MJF DATE 12 23 98 REV 11 PAGE NL401 urojs S 9811 N YS LI380 OR LI384A 11380 OR LI384A LI380 OR LI384A DOME LIGHT DOME LIGHT DOME LIGHT LI386 DOME 11380 OR LI384A 11380 OR LI384A 11380 OR LI384A ZON
87. e Call System Manual 51 52 ILA21 Tek MICRO Nurse Call System Manual Copyright TekTone Sound amp Signal Mfg Inc All Rights Reserved DOME LIGHT LI384A e Purple Blue Green e Gray 8 Purple CODE STATIONS SF332A SF341 Blue PRESENCE STATION SF350 Blue Green m Green STAFF EMERGENCY SF331A Blue 6 Green Yellow Yellow e Yellow Orange Orange Ne Orange BATH EMERGENCY SF330 SF 337 SF 340 SF 333 Blue e Yellow Orange BATH EMERGENCY SF337C Violet Blue Blue Green Yellow Orange subi 2 jeubis 9 punos euopyar 3ubu do ES ENUEN 5 ISMN amp O IOIIA2ISL Red Red Red Brown e Brown Red Brown Red IR300 Series Station 15 and 8 pin connectors P215 PIN Aide 15 Green White SF337C only Brown Nurse 14 Yellow White Bath 13 Orange White Emer Red White Monitor Brown White Monitor Monitor Code A Black Code B White Negative Gray 12 VDC Purple 12 VDC 12 VDC 12 VDC Lamp Fault Blu
88. e is also available Follow the procedures listed below to view station information Any deleted station will be shown in the view ALL station menu with the deleted SPUA Note On Main Menu numbers 8 and 9 used on NC350CP Series 8 and 9 not present on NC350C 64 Press MENU blue button MAIN MENU Help Menu Master Assignments Menu User Function Menu System Function Menu Set Room Privacy Page Room Monitoring Radio Pager Menu exit select menu item WM OURWNeE B Select User Function Menu by pressing 3 on keypad USER FUNCTION MENU 1 View Remote Stn 2 View Master Stn 3 View A Zone prev menu select menu item IL421 Tek MICRO Nurse Call System Manual 19 C Select View Remote Station by pressing 1 VIEW REMOTE STATIONS VIEW All Individual Code Call Routine Pers Attn Priority Privacy On Page Off Staff Duty Station select menu item Qo O Ui i QJ NJ ES prev menu D Follow additional menu instructions as prompted for specific information desired 3 18 ROOM MONITORING FUNCTION Note On Main Menu numbers 8 and 9 used on NC350CP Series 8 and 9 not present on NC350C 64 A Press MONITOR blue button to go directly to Enter Rooms To Be Monitored menu or use Room Monitoring on the main menu by pressing 5 on the keypad B Ente
89. e only 30 IL421 Tek MICRO Nurse Call System Manual F SF302 Mb AO 1 1 Plug Connects call cord to patient station when plugged into call cord jack 2 Push Button Places call when pressed if cord is connected to patient station 1 1 L P E SF311 v SF312 1 Plug Connects call cord to patient station when plugged into modular jack 2 Push Button Places call when pressed if cord is connected to patient station Fig 17 1 WZ 1 2 T au L 4 SF301P SF301PIR 1 Nurse Push Button Places a call when pressed if cord is connected to patient station 2 Push Button Turns TV on off and changes channels when pressed if cord is connected to patient station 3 Plug Connects pillow speaker to patient station when plugged into modular call cord jack not shown 4 Volume Control Controls volume for TV and radio only 5 Radio Push Button Controls 4 channel radio selection and radio on off Copyright TekTone Sound amp Signal Mfg Inc All Rights Reserved 4 3 IR310B STAFF AND IR315B DUTY STATIONS Refer to Fig 18 and Fig 19 for locations names and functions of controls and indicators A brief description of the operating controls for the staff and duty stations follows Reset Switch In Use Light The reset button is used to cancel a call placed from the station The light illuminates whenever communications to t
90. eat steps A E 3 22 and then perform the following A Select View Pager Zone Assignments by pressing 3 on keypad NO ID 87654321 400 NORD MMC 401 AUS ee rius 408 iue usc m exit down 3 24 PROGRAM RADIO PAGER CALL ASSIGNMENTS Programs the individual pager for receiving specific event message types Repeat steps A E 3 22 and then perform the following A Select Program Pager Call Assignments by pressing A on keypad PAGER CALL DISPLAY Code E Priority Fire E Duty Emergency Staff Monitor Pers Attn Bath Routine Cord Out Stat Faults Pager ID 0 0 menu next 0 1 on off Enter the pager number to be programmed and then press the key IL421 Tek MICRO Nurse Call System Manual 21 B Press 1 to turn ON OFF Press key to move through menu until prompted to save Default pro gramming is all zones and call responses ON NOTE The call type FAULTS in this menu refers to COMM LAMP and CODE faults 3 25 SPECIFY PAGER SYSTEM AND STATUS Toggles the event message location between printer and pager format Repeat steps A E 3 22 then perform the following A Select Specify Pager System and Status by pressing 1 on key pad PAGER STATUS Status PAGING DISABLED save 0 off 1 Motorola 2 Interpage Press 0 to
91. enu and selecting 1 Help Menu the user can access the help menu Figure 13 which allows access to nine different help menus as shown in Figure 14 through Figure 22 For the help menu access press options 1 through 9 which will bring up the related menus Pressing returns the user either to the main help menu or exits the help menu Accessing the Help Menu will not effect the operation of the system Figure 13 Figure 14 Figure 15 Figure 16 Figure 17 53 11421 Tek MICRO Manual Supplement Page A Zone Menu Help Menu 5 Page a Zone A Press PAGE button B Enter Zone Number 01 08 Local 11 18 across DSN 09 for all zones or TALK for all assigned zones Press TALK to speak or lift speak into handset D Press RESET or replace handset when complete menu reset exit Program Room Priority Menu Help Menu 6 Program Room Priority A Press SET PRIORITY button B Enter Room and Bed Number Press 1 to step through selections D Press to save and edit next room to return to previous menu or RESET to exitthe menu menu reset exit Program Patient Privacy Page Menu Help Menu 7 Program Patient P rivacy P age A From Main Menu enter option 4 B From Settings Menu enter option 1 or 2 Enter Room and Bed Number D Press 1 to step through selectio
92. er Emergency Station The SF337C is used to operate all BATH or EMERGENCY signals The station consists of a flame retardant white plastic face plate ared pull down lever a white rubber gasket a7 nylon cord with pendant and mounting screws with O Rings A circuit board with a reed switch connectors a red call placed indicator and electronic circuitry is mounted to the back of the face plate The SF337C is waterproof if properly installed 4 ILA21 Tek MICRO Nurse Call System Manual SE340B Emergency Station The SF340B is used to operate all BATH or EMERGENCY signals The station consists of a flame retardant white plastic face plate a red pull down lever 7 nylon cord with pendant and mounting screws A circuit board with a DPDT switch connectors a red call placed indica tor and electronic circuitry is mounted to the back of the face plate SE341B Code Call Station The SF341B Code Call Station is used to operate all CODE signals at a rate of twice that of medium priority signals The station consists of a flame retar dant white plastic face plate a blue pull down lever a 7 nylon cord with pendant and mounting screws A circuit board with a DPDT switch connectors a red call placed indicator and electronic circuitry is mounted to the back of the face plate SF336 SF338 Staff Emergency Psychiatric Station The SF336 SF338 provides emergency call signaling when used in con
93. er between brown wire on 8 pin connector to blue wire on 15 pin connector Refer to WIRING DIAGRAM NLA095 PK352 Battery Charger Assembly The battery charger assem bly should be located in an accessible area preferably with the system CPE Permitted operating temperature range of 10 C 30 C should not be exceeded Location should provide con venient wire run to CPE and master station Fasten the cabinet containing the battery charger assembly to the wall using suit able fasteners RY350B Multi Channel Relay The multi channel relay should be located for convenient access to radio audio cables These are usually terminated behind television if room is so equipped RY351B Hill Rom SideCom Adapter The adapter can be located near the Hill Rom P376 plug in adapter Both items must be located on the same wall as the patient station towards the lower half of the wall behind the bed The RY351B may also be located next to the patient station SF337C Pull Cord Waterproof Shower Emergency Call Stations The shower emergency station should be located where con venient for operation in areas such as toilets baths or shower rooms The SF337C may be used as a pull station or a pull cord station To use as a pull cord station thread nylon cord through hole provided in the GUIDE tab on lower position of the face plate and red pull down lever Secure with a double knot then mount station high enough for convenient
94. essing 3 keypad D Set desired overtime in 1 minute increments only with a maximum overtime of 9 minutes by pressing desired number of minutes on keypad After ROUTINE over time is set PRIORITY overtime is immediately ready to be set and then SERVICE overtime Categories cannot be set out of order If 0 is entered no overtime is set and no overtime OT message will appear SET CALL OVERTIMES Routine call 0 minute s Priority call 0 minute s Service call 0 minute s menu save enter time 0 9 3 14 SET PASSWORD A numerical password is used to keep unauthorized per sonnel from access to system programming functions No password is needed for access to system programming until a password is set following the procedures listed below If password is forgotten or lost contact factory for instructions on overriding the password requirement Sys tem reinitialization does not cancel password Note On Main Menu numbers 8 and 9 used on NC350CP Series 8 and 9 not present on NC350C 64 Press MENU blue button MAIN MENU Help Menu Master Assignments Menu User Function Menu System Function Menu Set Room Privacy Page Room Monitoring Radio Pager Menu exit select menu item B Select System Function Menu by pressing 4 on keypad SYSTEM FUNCTIONS Set Time Date 12 24 Hour Clock Set Overtim
95. et The unit may be desk or wall mounted SF Series Emergency Code Call Presence Stations Install a single gang ring or single gang ring double gang box TekTone 1 357 ring and 1 358 box as shown in Fig 3 for each station in system Minimum dimensions of the back box to be not less than 4 x 4 x 1 1 2 Minimum opening on the ring to be not less than 1 3 4 x 2 3 4 Minimum clearance from live parts on the station to dead metal parts to be not less than 1 2 Fig 3 SF337C Pull Pull Cord Waterproof Shower Emergency Call Station For housing installation follow the same instructions as in section 2 4 item H To insure a seal Copyright TekTone Sound amp Signal Mfg Inc All Rights Reserved between SF337C face plate and wall the gasket must be mounted between face plate and wall The mounting screws with must be used to further assure that there is a water tight installation Take care that the housing location will be such that the finished wall provides a flat even surface installation of the housing in the seams of tile will require additional caulking between gasket and wall The SF337C is waterproof if properly installed 2 5 WIRE CHECK OUT A Use an ohm meter or other continuity checking device to test wires for shorts or grounds If shorts or grounds are encountered find and correct the problem before continuing ALL SHIELD DRAIN WIRES MUST SHOW CONTINUITY THROUGHOUT
96. ger Menu exit select menu item Select System Function Menu by pressing 4 keypad SYSTEM FUNCTIONS Set Time Date 12 24 Hour Clock Set Overtime Reconfiguration Hook Switch prev menu select menu item Ui OU NH C Select 12 24 Hour Clock by pressing 2 on keypad SELECT CLOCK MODE Mode 12 Hour Format menu 1 toggle mode D Press 1 on keypad for desired mode Press key to save and return to previous menu Copyright TekTone Sound amp Signal Mfg Inc All Rights Reserved 3 12 SET TIME DATE If the time must be corrected follow the procedure listed below Note On Main Menu numbers 8 and 9 used on NC350CP Series 8 and 9 not present on NC350C 64 A Press MENU blue button MAIN MENU Help Menu Master Assignments Menu User Function Menu System Function Menu Set Room Privacy Page Room Monitoring Radio Pager Menu exit select menu item w Select System Function Menu by pressing 4 on keypad SYSTEM FUNCTIONS Set Time Date 12 24 Hour Clock Set Overtime Reconfiguration Hook Switch prev menu select menu item C Select Set Time Date by pressing 1 on keypad SET TIME AND DATE Set Time 24 hours and Date Format hh mm mm dd yy 11 27 12 17 94 menu
97. gnals canceled Initiate Nurse Follower by pressing NURSE FOL LOWER orange button There should be no calls waiting on the system Check for following at master station 1 NURSE FOLLOWER orange button LED steadily illuminated 2 NURSEFOLLOWER ON displays on monitor Register a nurse present at any presence station by Copyright TekTone Sound amp Signal Mfg Inc All Rights Reserved pressing green NURSE button Place a call from any patient station in the same zone Check for following at master station 1 NURSE FOLLOWER orange button LED on and NURSE FOLLOWER ON displays on monitor 2 Call light button LED slowly flashes during signal transmission 3 Call information appears on call screen Room number where nurse is registered displays steady under NURSE Check for following at patient station to which a nurse is registered 1 Reset In use light steadily illuminated 2 Tone signal every 8 seconds 3 Dome light green lamp on steady Check for following at duty station in the same zone 1 Call placed light flashing 2 Tone signal every 8 seconds 3 Dome lights white and green lamps on steady Check for following at nurse presence station to which a nurses presence has been canceled 1 Call information disappears on the call screen where the nurse was registered Toggle off the NURSE FOLLOWER key at master station Check for following
98. he master station is engaged On the duty station only the reset button may be used to silence the tone signal for low priority calls Medium and high priority tone signals cannot be silenced The tone will return only after all low priority calls have been canceled or a medium or high priority call is placed Call Button Call Placed Light The call button is used to place a call to the master The light flashes when a call is placed The call light also flashes when an emergency call is placed from any emergency type station associated with the staff or duty station Emergency Light On the duty station only the light alter nately flashes with the call placed light to indicate a medium or high priority call as described below Priority Signals On the duty station only whenever a call is placed anywhere in the zone served by the duty station one of the following occurs Low Priority Calls The call placed light flashes and one tone repeated every 8 seconds is heard from the speaker Medium Priority Calls The emergency light and call placed light alternately flash and a slow repeating tone is heard from the speaker IR310B STAFF STATION SPEAKER MICROPHONE CALL BUTTON CALL PLACED LIGHT TekTone RESET SWITCH IN USE LIGHT Fig 18 Copyright TekTone Sound amp Signal Mfg Inc All Rights Reserved High Priority Calls The emergency light and call placed light alternately flash at twi
99. ial output 9600 baud 8 data bits 1 stop bitparity none Note Uselow capacitance cable for cable runs over 100 500 NC357BP SERIAL CABLE CONFIGURATION FOR OKIDATA 182 PLUS DB25 FEMALE DB25 MALE on CPE PRINTER YAWN NC362P SERIAL CABLE CONFIGURATION FOR OKIDATA 182 PLUS DB9 FEMALE DB25 FEMALE NC362 PRINTER SERIAL PORT 11 NC363P SERIAL CABLE CONFIGURATION FOR MOTOROLA PEOPLE FINDER DB25 FEMALE DB25 FEMALE NC363P PEOPLE FINDER 421 Tek MICRO Nurse Call System Manual 7 NC362 SERIAL CABLE CONFIGURATION FOR II SYSTEM DB9 FEMALE DB25 FEMALE NC362 Tek MMARS II SYSTEM NC362 SERIAL CABLE CONFIGURATION FOR INTERPAGE SYSTEM DB9 FEMALE DB25 FEMALE NC362 INTERPAGE NC350CP Series to NC350CP Series 1 twisted pair shielded 18 plus 1 twisted pair shielded 18 individu ally jacketed plus 4 cond 18 plus 1 cond 16 Cable must be of low capacitance 23 pF foot type 2 4 HOUSING INSTALLATION A IR Series Patient Staff Duty Multipurpose Stations Install the back box TekTone 41H353 Steel City H3BD with TekTone 1 352 Steel City 3GC plas ter ring or EXACT EQUIVALENT as shown in Fig 1 foreach station in system Minimum dimensions of the back box to be not less than 8 6 x 4 5 x 2 5 Minimum clearance from live parts on the station to dead metal parts to be not less than 1 2 IMPOR TANT Before installing IR Series stations onto hous
100. ights Reserved CODE STATIONS SF332A SF341B Gray Purple Blue Green Yellow Red Brown e STAFF EMERGENCY SF331A Blue e Green Yellow ngl range e Orange BATH EMERGENCY SF330 SF 337B SF 340B SF 333 Blue Green Yellow Red Red e Brown e e Brown peuesauy 9 2 jeubis 9 punos euopyar 1ubu do L9 Tenure urojs S 9SInN gOSIOTIA2ISL 11386 DOME ZONE LIGHT 15 and 8 pin connectors P215PIN Green White Yellow White _ Orange White Red White EMERGENCY Brown White Black White Gray Purple Blue Green Yellow Orange Red Brown 22 12 VDC LED Output e o Smoke Detector Contacts Normally Open Not Used Not Used 12 VDC Data Com Data Out Data In Negative 24 VDC Purple Blue Green Yellow oe Optional Method for Smoke Detector Orange Red Brown input is used Note Use only if Emergency NOTE FIRE INDICATION AT THE NURSE MASTER IS SUPPLEMENTARY ONLY THE NC300 SYSTEM IS NOT INTENDED FOR USE AS A FIRE ALARM EVACUATI
101. ignal Mfg Inc All Rights Reserved LI386 Zone Dome Light Data Assembly 1 twisted pair plus 1 cond 18 gauge stranded wire plus 3 single conductors 18 gauge stranded plus 1 single conductor 16 gauge stranded common cable directly from CPE to LI386 Dome Lights SF Series Emergency Code Call Stations Home run 5 cond 22 from each patient duty or staff station for associated emergency code call stations SE350B Presence Station Home run 6 cond 22 from each patient duty or staff station for associated pres ence stations RY350B Multi Channel Relay Run 1 pair 18 gauge to 12 VDC power supply from RY350B Run pair 18 gauge from RY350B to television location Run 5 conductor 18 gauge from RY350B to IR311B IR312B Note One RY350B is required per pillow speaker requiring radio entertainment Run 1 conductor 18 gauge from television location to IR311B IR312B RY351B Hill Rom SideCom Adapter Run 15 con ductor 22 gauge shielded wire from TekTone RY351B location to IR311B IR312B Patient Station Run 15 conductor 22 gauge shielded wire from RY351B to P376 Please note a Hill Rom P376 Plug in Adapter is supplied with 6 of cable When using P376run CABLE and C to RY351B run CABLE A to other devices as per Hill Rom instructions NC357BP NC362P Printer Outputs Use four conductor shielded cable not to exceed 100 in length Set DIP switches on printer for IBM ser
102. ignal slowly repeating 3 Call information displayed on call screen Call priority indication is CORD OUT Check for following at duty station in the same zone 1 Call placed light and emergency light alter nately flashing 2 Tone signal slowly repeating 3 Dome light white lamp slowly flashing G Replace call cord Check for following at all stations 1 All signals canceled NOTE Calls may be placed from IR315B Duty Stations in the same manner as described above H Testing for a Deleted Station Place a call to the deleted room and check for the following 1 There should be no tones signals or communi cation links with the deleted station Delete a station and create a COMM FAULT Check for the following 1 The room deleted does not appear on the list of rooms with COMM FAULT on the monitor Repair the COMM FAULT by plugging the cable back in and check for the following 1 No message should appear on the monitor Create a LAMP FAULT by removing a bulb from the attached light fixture then delete the station with the lamp fault Check for the following 1 LAMP FAULT should have appeared at the monitor and then disappeared when the station was deleted Add the station back and then repair the LAMP FAULT Check for the following 1 LAMP FAULT should appear back on the moni tor 2 White lamp should be flashing 3 Station call placed light should be
103. ing port The NC300 Software Version 1 94 may be configured for use with pagers or aline printer The event message format may be toggled between pager and printer format from the menu system Up to 48 pagers may be in use at any one time and each of these may be individually programmed to receive only the specific 28 IL421 Tek MICRO Nurse Call System Manual types of calls desired NOTE Default for message format is Printer Since printer and pager event formats differ the event message format should be checked and set for desired configuration See System Programming Section 3 22 3 25 for complete instructions on how to program and operate pagers Copyright TekTone Sound amp Signal Mfg Inc All Rights Reserved 4 2 IR301B IR302B IR311B IR312B IR318 PATIENT STATIONS Refer to Figures 11 through 15 for locations names and func tions of controls and indicators A brief description of the operating controls for the patient stations follows Reset Switch In Use Light The reset button is used to cancel a call placed from the station The light illuminates whenever communications to the master station is engaged Call Placed Light The call placed light flashes when any call is placed from the patient station IR301B SINGLE PATIENT STATION SPEAKER MICROPHONE Fig 11 TekTone o CALL CORD RECEPTACLE RESET SWITCH CALL PLACED IN USE LIGHT LIGHT IR302B DUAL PATIENT STATION SPEAKER M
104. l Processing Equipment CPE The NC350C 64 CPE provides for all the microcomputer multiplex tech nology necessary to operate all NC300 System functions and interface with up to two NC303 Master Stations up to 64 remote patient stations and all other emergency and presence stations associated with each nurse call system The CPE consists of microcomputer memory and interface circuits and power sup ply Two talk paths are provided per CPE Power input is 115 V 60 Hz 125 W All outputs are protected by self resetting current limiting circuits All equipment is completely contained in a PC type cabinet Optional battery backup available TekTone model number PK250 NC362UP serial interface upgrade The NC362UP is used to upgrade an existing NC350C 64 to add event printing capabili ties to the NC300 Nurse Call System if connected to a compat ible printer The NC362UP may also be used to interface to radio pocket paging or to connect to a NC386A 8 Management System SAMPLE OF EVENT PRINT OUT NO DATE TIME STATION EVENT ZONE STN O o 00 09 19 12 28 48 8402 ROUTINE CALL eee 01 09 19 12 28 56 8409 1 DUTY CALL wc and 02 09 19 12 28 58 8409 DUTY RESET vau o 03 09 19 12 29 35 8406 BATH CALL 04 09 19 12 29 39 8406 RESET iU is 905 09 19 12 29 57 01 TALK INITIATED 4 8402 o 06 09 19 12 30 06 01 NURSE REQUESTED 4 8402 07 09 19 12 30 08 01 TALK
105. later Copyright TekTone Sound amp Signal Mfg Inc All Rights Reserved Press the RESET black button or hang up handset when finished Paging establishes master station communication to stations other than masters to which it has been previously assigned If a specific zone is not se lected after pressing the PAGE gray button an ALL CALL is initiated when the TALK white button is pressed and the page will be heard by all stations zoned to the paging master If 9 is selected after pressing the PAGE gray button paging is heard at all stations on the system Only one master at a time per system may be in ALL CALL paging communications On another master attempting an ALL CALL PAGE the display will indicate BUSY when one master already is in an ALL CALL PAGE mode If a master station is assigned to all zones no routine communication is possible anywhere on the system while it is in ALL CALL NOTE Paging communication is two way unless the number of stations paged per port exceeds 30 Two way paging may be used to monitor pre assigned zones or individual stations may be as signed to any unused zones for monitoring pur poses See System Configuration Section 3 1 for Programming Station Zone Assignments ALL CALL feature not available across DSN 4 1 14 NURSE AIDE PAGING 1 4 1 15 Press PAGE gray button Press NURSE green button and or AIDE yellow b
106. led and will disap pear from the screen If a service request overtime call is placed the call cannot be canceled from the master The call can only be canceled at the patient station or as a result of the nurse or aide registering presence in the room then pressing the appropriate NURSE or AIDE button again when leaving TO REQUEST STAT SERVICE 1 Select the room number as for communications 2 Press the STAT red button The room number will flash in the STAT area on the screen If desired communication may be established with the station to inform them assistance has been requested A stat service may also be requested when a call is initiated at the patient station when the TALK key is pressed to answer the incoming call then STAT can be pressed and the reset button is pressed to cancel communication NOTE STAT service cannot be requested to loca tions where devices are connected to an LI386 Ad dressable Dome Zone Light Copyright TekTone Sound amp Signal Mfg Inc All Rights Reserved 4 1 9 4 1 10 4 1 11 4 1 12 4 1 13 TO CANCEL STAT SERVICE REQUEST 1 Stat service request must be canceled at the se lected station Stat service requests require attention from the nearest staff member The system will continue signaling at the associated dome light until the selected station is indicating that a staff member has responded If an overtime ca
107. lete operating information for all NC300 System Equipment in addition to drawing references for use in locating and describing all controls and indicators System operators should read the following operating instructions concerning system equipment and terms used in conjunction with the equipment 41 1 NC303 MASTER STATION NC310B VIDEO MONITOR Refer to Fig 9 and Fig 10 for locations names and functions of controls and indicators A brief description of the operating controls for the NC303 and NC310B follows NC303 Fig 9 CPE FAULT DIP SWITCHES BEEP TONE LIGHT ON OFF SWITCH 1 2 4 8 actual 1 2 3 4 3 SWITCHES 1 2 3 4 5 6 7 for reference only DIP SWITCH VALUES Address Master Address Master Address Master ON ALWAYS Not Used Not Used Not Used Beep Tone Switch DownzON HOOK SWITCH VOLUME HANDSET CONTROL Handset The handset is used to provide confidential conversation when loudspeaker communication is not desired and when master to master communication is necessary or to permit conversation when high ambient noise is present To use simply pick up handset Volume Control The volume control permits adjustment of the incoming voice communication It may also be used to reduce the level of the tone signal during quiet periods of operation Function Buttons These buttons select the most used system functions and are described below RESET black
108. ll is placed the call can only be canceled at the patient station TO PAGE A ZONE 1 2 Press the PAGE gray button Enter the desired zone number 1 8 on keypad PAGE will appear in the call window If BUSY appears the page is in use by another master station in communication with the same circuit Press the TALK white button while speaking or pick up handset Press the RESET black button or hang up handset when finished TO PAGE A ZONE ACROSS DSN 1 2 Press the PAGE gray button Enter the desired zone number 11 18 on keypad PAGE will appear in the call window If BUSY appears the page is in use by another master station in communication with the same circuit Press the TALK white button while speaking or pick up handset Press the RESET black button or hang up handset when finished TO PAGE ALL ASSIGNED ZONES 1 2 Press the PAGE gray button Press the TALK white button while speaking or pick up handset If BUSY appears the circuit is in use by another master Try again later Press the RESET black button or hang up handset when finished TO PAGE ALL STATIONS ON SYSTEM 1 2 3 Press the PAGE gray button Press 9 on the keypad Press the TALK white button while speaking or pick up handset If BUSY appears the circuit is in use by another master Try again
109. low Page a Zone Program Room Priority Program Station Privacy P age Change Master or Station Zones Call Another Master Station 10 00 cL OP GE Ga SES exit select 1 9 Answer A Call Menu Help Menu 1 Answer a Call A Press TALK button or lift handset B Press TALK button to speak and release to listen or use handset Press RESET or replace handset menu reset exit Place A Call Menu Help Menu 2 Place a Call A Type Room Number on Keypad then press P B Press TALK button to speak and release to listen or lift and speak into handset C Press RESET or replace handset Request Service Menu menu reset exit Help Menu 3 Request Nurse Asst Stat Service Tu A Type Room Number on Keypad then P B Press NURSE ASST or STAT button C Press TALK then reset CANCEL NURSE ASST STAT SERVICE D Type Room Number on Keypad then Press NURSE or ASST button E Cancel STAT by room station reset menu reset exit Nurse Follower Menu Help Menu 4 Call Follow A Press CALL FOLLOW button register in room call will be sent to room or B Enter Room Number and press Press CALL FOLLOW calls sent to room D To cancel CALL FOLLOW press CALL FOLLOW button menu reset exit 3 0 Help Screen By pressing the M
110. lternately rapidly flashing 2 Tone signal rapidly repeating 3 Dome lights white and red lamps alternately rapidly flashing for call placed from code call station Reset each code call station as described in the System Operating Section 4 0 page 23 Check for following at code call patient duty and master stations 40 IL421 Tek MICRO Nurse Call System Manual 1 All signals canceled 6 6 SF350B NURSE AIDE PRESENCE STATION TEST PROCEDURE A Register nurse and aide presence on each presence station as described in the System Operating Section 4 0 page 23 Check for following at presence station 1 Nurse light green steadily illuminated 2 Aide light yellow steadily illuminated Check for following at associated patient station 1 Dome light green lamp steadily illuminated 2 Dome light yellow lamp steadily illuminated Check for following at master station 1 Room number of associated patient station appears steady in NURSE area of call screen 2 Room number of associated patient station appears steady in AIDE area of call screen Check for following at duty station in the same zone 1 Dome light green lamp steadily illuminated 2 Dome light yellow lamp steadily illuminated Cancel nurse and aide registration as described in the System Operating Section 4 0 page 23 Check for following at presence patient duty and master stations 1 All signals canceled
111. ming Sheet SPUA Default ASSIG BED ZONE NO PRIOR PAG PRV CODE LABEL RM BED ROOM R P PA ON OFF ON OFF ON OFF 1100 8100 1 1101 8101 1 1102 8102 1 1103 8103 1 1104 8104 1 1105 8105 1 1106 8106 1 1107 8107 1 1108 8108 1 1109 8109 1 1110 8110 1 1111 8111 1 1112 8112 1 1113 8113 1 1114 8114 1 1115 8115 1 1116 8116 1 1117 8117 1 1118 8118 1 1119 8119 1 1120 8120 1 1121 8121 1 1122 8122 1 1123 8123 1 1124 8124 1 1125 8125 1 1126 8126 1 1127 8127 1 1128 8128 1 1129 8129 1 1130 8130 1 1131 8131 1 Example of how information appears on View Station menu 1101 8101 1 1 2 3 P ON OFF OFF SPUA System Port Unit Address PRIOR of station Routine or EIN P Priority or PA Personal Attention ZONE NO Zone Station is programmed for System PAG Paging set on or off zone will default to physical port station is PRV Privacy set on or off connected to CODE Onoroff Copyright TekTone Sound amp Signal Mfg Inc All Rights Reserved ILA21 Tek MICRO Nurse Call System Manual 43 Port 1 Programming Sheet SPUA Default ASSIG BED ZONE NO
112. mmed for privacy 321 TO PROGRAM STATION PAGING Note On Main Menu numbers 8 and 9 used on NC350CP Series 8 and 9 not present on NC350C 64 A Press the MENU blue button MAIN MENU 1 Help Menu 2 Master Assignments Menu 3 User Function Menu 4 System Function Menu 5 6 7 SetRoom Privacy Page Room Monitoring Radio Pager Menu select menu item Copyright TekTone Sound amp Signal Mfg Inc All Rights Reserved B Select Set Room Privacy and Page by pressing 5 on keypad SET ROOM PRIVACY AND PAGE 1 SetRoom Privacy 2 SetRoom Page prev menu select menu item C Select Set Room Page by pressing 2 on keypad SET ROOM PAGING Room amp Bed No Paging Status menu enter enter room id D Enter room and bed number SET ROOM PAGING Room amp Bed No 8108 1 Paging Status ON menu save 1 toggle selection E Select paging ON OFF by pressing 1 Press the amp to save No type of paging communication from the master station will be heard at a station programmed for no paging 3 22 TO PROGRAM RADIO PAGER SYSTEM Program Pager Zone Assignments permits programming a pager to receive event messages from specific zones Note On Main Menu numbers 8 and 9 used on NC350CP Series 8 and 9 not present on NC350C
113. n from dome light to dome light from station to station or acombination of the two TekTone recommends dome light to dome light wiring because of the reduced wire lengths DO NOT RUN CONDUIT OR WIRE TO BOTTOM KNOCKOUTS OF IR SERIES STA TION BOX NO ACCESS IS AVAILABLE A NC303 Master Station Run Data Assembly 1 twisted pair plus 1 cond 18 gauge stranded wire and an Audio Assembly 1 twisted pair 18 gauge stranded wire plus 3 single conductors 18 gauge stranded plus 1 single conductor 16 gauge stranded directly to the NC350C Central Processing Equipment Each master must be home run to the CPE NC310B Video Monitor Run RG59U cable with con nectors at both ends directly to NC350CP Series CPE C IR Series Patient Duty Staff Stations If LI380 Dome Lights are used run Data Assembly 1 twisted pair plus 1 cond 18 gauge stranded wire and an Audio Assembly 1 twisted pair 18 gauge stranded wire plus 4 single conductors 18 gauge stranded plus 1 single conductor 16 gauge stranded common cable directly from CPE to LI380 Dome Lights Repeat common cable plus 5 cond 22 directly to patient duty or staff stations If LI384A Dome Lights are used run common cable plus 8 cond 22 directly to patient duty or staff stations If dome lights are not used run com mon cable directly from CPE to stations See first paragraph under this section for specific wire type Copyright TekTone Sound amp S
114. n stata stata tns tata esta senes enean 31 ROOM BED NUMBER AND ZONING ASSIGNMENTS 13 3 2 TO CHANGE DUTY STATION CALL 0 14 3 3 DUTY STATION DSN ZONE CAPTURE NC350CP 14 3 4 ADD DELETE STATION cett 3 5 MASTER ASSIGNMENT MENU 3 6 MASTER CALL RESPONSE x 3 7 JNTERCOM PREANNOUNGE CALI TONES tete rede e ee e DER pe eed 16 3 8 DSN SEATUS NG350CP SENES erie i eaaa do 16 3 9 DSN ZONE CAPTURE NC350CP Series 3 10 ADDING OR REMOVING MASTER STATIONS 17 SET 12 OR 24 HOUR CLOCK FORMA TD 17 3 12 SET TIME DATE 3 13 SET CALL OVERTIME 3 14 SET PASSWORD 3 15 SEPCODESTATION ON OEB RU de ide dr e RATE Reve 3 16 REINITIAEIZE SY STEM ep ALAIN RO EON EROR sexes var d RAMIS 3 17 VIEW STATION CONFIGURATIONS gt 3 18 ROOM MONITORING FUNCTION 3 19 PATIENT PRIORELY tete etr Dee e ele 3 20 7TO PROGRAM STATION PRIVACY etae e ep t ee P ES EEE Ra Red RH 3 2 PROGRAM STATION PAGING siii nt edo ao e e pone px ee We HRS 3 22 TO PROGRAM RADIO PAGER SYSTEM a 3 23 VIEW RA
115. n the cooling fan circuit in the CPE which may result in overheating and system failure Contact qualified maintenance person nel TROUBLE MASTER STATION indicates a fault in the wiring to one of the master stations or a defective master station The affected master station will be unable to operate FAULT will appear in call window for master station specified TROUBLE DSN indicates DSN communication link problems NC350CP Series CPE only CPE FAULT indicates CPE failure CPE light at mas ter station will remain on steady Other Calls Bed Out For use with RY351B Hill Rom Adapter Indi cates if bed has been disconnected from wall plate Aide Displays the room numbers where an aide 15 regis tered present or where an aide is required Nurse Displays the room numbers where a nurse is regis tered present or where a nurse is required Stat Displays the room numbers where a nurse and or aide is registered present or where an urgent STAT service request has been placed Call Window Displays the currently selected call for one master station Copyright TekTone Sound amp Signal Mfg Inc All Rights Reserved Nurse Follow ON Indicates when Nurse Follower is active Tone OFF Indicates routine call tone OPERATION 41 2 TO ANSWER A CALL AUTOMATICALLY 1 Press the TALK white button or pick up the handset Thecalltone will be silenced and commu nications established
116. ndication of call origin call priority and staff presence A brief description of LI380 and LI384A operation follows NOTE Model LI384A is a Supervised Dome Light In case of LI384A fault LAMP FAULT will be indicated at the master station Lamps The red green yellow and white lamps are used to indicate call priority and staff presence When used in association with any room station all calls originated from that room will be indicated by lamp signal s as described below When used as a zone light with an IR315B Duty Station or LI386 all calls originated from the zones to which the duty station is assigned will be indicated by lamp signal s as described below LAMP INDICATION High Priority CODE CALL Alternately flashing red white FIRE Red flashing supplementary only EMERGENCY White flashing STAT SERVICE REQUEST Alternating flashing green yellow Medium Priority MONITOR Red flashing BATH White flashing BED OUT White flashing CORD OUT White flashing PRIORITY White flashing NURSE SERVICE REQUEST Green flashing AIDE SERVICE REQUEST Yellow flashing Low Priority STAFF White steady DUTY White steady PERS ATTN White steady ROUTINE White steady NURSE PRESENT Green steady AIDE PRESENT Yellow steady System Status COMM FAULT No dome light indication CODEFAULT Nodome light indication LAMP FAULT Red yellow or green lamp out white lamp flashing onLI384A white lamp out
117. ne signal every 8 seconds 3 Dome light white lamp on steady Test intercom function from master station by pressing TALK white button as previously described Check for following at patient staff stations 1 Call placed light flashing 2 Reset In Uselightsteadily illuminated except with SF301PI Series 3 Dome light white lamp canceled Press Reset In Use Button Check for following at all stations 1 All signals canceled Change station call priority to PRIORITY and repeat above procedure Check for following at patient station 1 Call placed light slowly flashes 2 Dome light white lamp slowly flashing Check for following at master station 1 Call light slowly flashing 2 Tone signal slowly repeating 3 Callinformation appears on call screen with PRIORITY call priority Check for following at duty station in the same zone 1 Call placed light and emergency light alternately flashing 2 Tone signal slowly repeating 3 Dome light white lamp slowly flashing Reset PRIORITY call at patient station Check for following at all stations 1 All signals canceled Remove call cord or pillow speaker from receptacle on patient station Check for following at patient station 1 Call placed light slowly flashing Copyright TekTone Sound amp Signal Mfg Inc All Rights Reserved Check for following at master station 1 Call placed light slowly flashing 2 Tone s
118. nection through a 1 megohm resistor Nursing staff must be trained to disconnect and reconnect the ground whenever beds have to be moved 3 Use grounded appliances and equipment near nurse call systems The use of approved electrical equipment will usually take care of this This information is provided to make you aware of ESD problems so that precautions may be taken to avoid damage and disruption of system operation Copyright TekTone Sound amp Signal Mfg Inc All Rights Reserved IL421 Tek MICROS Nurse Call System Manual 1 2 421 Tek MICRO Nurse Call System Manual Copyright TekTone Sound amp Signal Mfg Inc All Rights Reserved 2 0 INSTALLATION PROCEDURE gt Read the following instructions concerning system equip ment and determine installation methods before proceeding Determine equipment locations Install wiring Install housings Check wires Set station addresses Connect equipment Check connections Test system Configure system Train system operators AS Soe so ae Note When replacing IR311 A IR312A amp IR300A with IR311B IR312B amp IR300B the female 6 pin connector must be replaced with a 7 pin connector P N CT307 2 1 EQUIPMENT REQUIREMENTS AND APPLICATION The NC300 System is designed as a zoned floor system with the flexibility to connect to other floor systems to control an entire hospital A typical system will include the following NC350C 64 Centra
119. ng 1 2 3 4 5 6 7 8 Room No 8201 1 1 Bed 2 2 menu 1 9 assign zones save Updated data will now be stored Loss of power to system will not result in loss of data however system reinitialization will cause loss of all previously pro grammed data except password Repeat this procedure until all room numbers have been assigned RESET will exit the program at any time 421 Tek MICRO Nurse Call System Manual 13 3 2 TO CHANGE DUTY STATION CALL RESPONSE 3 3 DUTY STATION DSN ZONE CAPTURE NC350CP SERIES Note On Main Menu numbers 8 and 9 used on NC350CP Series 8 and 9 not present on NC350C 64 The Duty Station DSN Zone Capture responds to other zones across the DSN port Default is all zones Press the MENU blue button MAIN MENU A Press the MENU blue button 1 Help Menu 2 Master Assignments Menu MAIN MENU 3 User Function Menu 1 Help Menu 4 System Function Menu 2 Master Assignments Menu 5 Set Room Privacy Page 3 User Function Menu 6 Room Monitoring 4 System Function Menu 7 Radio Pager Menu 5 Set Room Privacy Page exit select menu item 6 Room Monitoring 7 Radio Pager Menu 8 Dual System Status B Select System Function Menu by pressing 4 on keypad 9 Dual System Zone Capture SYSTEM FUNCTIONS exit select menu item 1 Set Time Date 2 12 24 Hour Clock os 3 Set Ove
120. ns E Press to save and edit next room to return to previous menu or RESET to exit the menu menu reset exit Change Master or Zone Station Menu Help Menu Change Master or Station Zones Zones are marked with an X B Press numbers for Zones desired or 9 for all Zones to save and exit Change Station Zones C Press MENU button then press 3 then press 4 then press 1 then 1 again D Enter Room and Bed Number Label and Zone Press to save and edit next room menu reset exit Call Another Master Menu Help Menu 9 Call Another Master A Enter Master Number 01 08 on keypad B Press TALK button or lift handset C Press TALK button to speak and release to listen or use handset D Press RESET or replace handset menu reset exit Figure 18 Figure 19 Figure 20 Figure 21 Figure 22 4 1 4 2 4 3 4 4 4 5 4 6 4 0 NC300 Trouble Shooting Guide CODE FAULT Check a b Wiring from code SF341B Station to patient sta tion Check station CODE ON OFF programming If patient has CODE on and there is no CODE station connected fault will appear on NC310B Monitor COMM FAULT Check a b a b Wiring to station has that fault Station address No two stations on a port can be addressed identically N
121. nto a ROUTINE CALL STATION IR315B Duty Station The IR315B Duty Station provides for call indication and reliable two way hands free communication between the nurse master station and any location where a nurse may perform a function out of hearing or sight range of the master station The station consists of LSI microprocessor tech nology yellow call placed indicator combination in use indi cator and reset button and speaker microphone The IR315B is mounted on a flame retardant type ABS plastic panel IR316 Psychiatric Station Provides audible visual and digital communication to and from the CPE including the nurse master and video monitor Model IR316 includes solid state LSI microprocessor technology yellow call placed indicator key switch and combination red in use indicator and reset button mounted on a rugged extruded aluminum panel RY351B Hill Rom SideCom Adapter Provides for interface with a Hill Rom SideCom unit to the NC300 Nurse Call System via an IR311B IR312B Patient Station The RY351B will transfer all functions associated with patient stations that have intercom type pillow speakers to the Hill Rom SideCom unit This includes intercom call placed indicator and in use indicator The RY351B is mounted on a single gang aluminum subplate The RY351B provides for a non cancelable call at the NC310B Monitor should the bed be unplugged from the wall SF337C Pull Cord Waterproof Show
122. nual 9 stations on one port must be numbered consecu tively e g 8100 8101 8102 8103 etc up to 32 stations 64 stations on NC350CPX2 port Station numbers will be assigned automatically Use only 0 31 0 63 for NC350CPX2 for station ad dresses 3 During System Test Section 6 0 make note on the chart provided of the actual room number where station is located The chart provides a handy refer ence for use in changing room numbers during system configuration After station addresses are set plug in connector cable assemblies supplied with each station to appropriate con nector on station If PM311C or PM312C Pillow Speaker modules are being used connector cable assembly will be plugged into module connectors Connect wires as shown in WIRING DIAGRAM NL401 and NL405 F SFSeries Emergency Code Call Presence Stations Plug in connector cable assembly supplied with each station Con nect wires as shown in WIRING DIAGRAM NLAOI LI380 LI384A Corridor or Dome Lights Connect wires as shown WIRING DIAGRAM NL401 or NL405 as needed H LI386 Dome Light Connect wires as shown in WIRING DIAGRAM NLA02 and NL415 as needed PK352 Battery Charger Assembly Connect wires as shown in WIRING DIAGRAM NL406 J RY350B Multi Channel Relay Connect wires as shown in WIRING DIAGRAM NL407 2 7 MASTER STATION SETTINGS amp ADJUSTMENTS All masters are shipped from the factory pre set as Master
123. on at the master station in addition to all visual indications provided by the LI380 LI386 Dome Light The LI386 provides visual indication of call origination as the LI380 does but also supplies an address point for communication to and from the CPE for remotely mounted devices such as stand alone switches ie public area bath The LI386 will also indicate calls from zones to which those stations are assigned zone light function PM311C PM312C Pillow Speaker Modules The PM311C and PM312C when used with IR311B and IR312B Patient Stations respectively provide for reliable two way hands free commu Copyright TekTone Sound amp Signal Mfg Inc All Rights Reserved nication between patient and nurse through the SF301PI Series Pillow Speaker The modules mount directly to the plug in connectors located on the IR311B or IR312B station circuit boards Standard SF301P Pillow Speaker or SF311 SF312 Call Cords may be added without removal of modules PK352 Battery Charger Assembly The PK352 battery charger assembly provides continuous 12 volts DC to one master per system Incase of CPE failure lamp indication of CPE fault will be seen at the master station and a continuous tone will be heard Tone can be canceled by pressing TALK at master RY350B Multi Channel Relay The RY350B Multi Channel Relay provides for the selection of entertainment program sources by the patient or user when actuated using TekTon
124. on for one patient the IR302B provides communication for two patients The stations consist of LSI microprocessor technology yellow call placed indicator s patient call cord receptacle s combination red in use indicator and reset button and speaker microphone The IR301B and IR302B are mounted on an ABS plastic panel IL421 Tek MICRO Nurse Call System Manual 3 IR311B Single IR312B Dual Patient Stations The IR311B Single and IR312B Dual Patient Stations provide two way hands free communication between the patient and the nurse The IR311B provides communication for one patient the IR312B provides communication for two patients The stations consist of LSI microprocessor technology yellow call placed indicator s call cord pillow speaker receptacle s combina tion in use indicator and reset button and speaker microphone The IR311B and IR312B are mounted on a flame retardant type ABS plastic panel IR310B Staff Station The IR310B Staff Station provides reli able two way hands free communication between the nurse master station and any location where staff members may need to originate calls or where cord sets are not required The station consists of LSI microprocessor technology combination yellow call placed indicator and call button combination red in use indicator and reset button and speaker microphone The IR310B is mounted on a flame retardant type ABS panel Turning DIP switch 7 ON turns IR310B i
125. on steady to indicate aide presence has been registered and is canceled when the aide registers out T kTone Nurse Registration Light Button AIDE Aide Registration Oka Light Button Fig 23 Copyright TekTone Sound amp Signal Mfg Inc All Rights Reserved OPERATION A TO REGISTER NURSE PRESENCE 1 Push the green button designated NURSE TO CANCEL NURSE PRESENCE 1 Push the green button designated NURSE C TO REGISTER AIDE PRESENCE 1 Push yellow button designated AIDE D TO CANCEL AIDE PRESENCE 1 Push yellow button designated AIDE 48 SE337C PULL PULL CORD WATERPROOF SHOWER EMERGENCY CALL STATION Refer to Fig 24 for locations names and functions of controls and indicators Refer to WIRING DIAGRAMS NL401 NL405 and NL415 for wiring outputs provided for dome light indica tion A brief description of the operating controls for the SF337C follows Emergency Pull Down Reset Lever The emergency pull down reset lever is used to place and cancel bath priority calls Call Placed Light The red LED flashes to indicate call place ment TekTone Call Placed Light Emergency Pull Down Reset Lever EMERGENCY Guide Tab ENS Cord 2 Call Cord Field Installation SS option refer to Sec 2 2
126. on while speaking and release to listen If the handset is being used it is not necessary to press the TALK button while talking 4 To cancel press the RESET black button or hang up handset Calls may be placed to patient staff or duty stations in the same manner regardless of calls waiting NOTE If a patient station is in privacy mode no audio can be heard at the calling master from that station Privacy does not affect calls initiated from the patient station 41 5 TO PLACE CALL TO ANOTHER MASTER STATION 1 Dialthe desired master station number 01 08 the keypad The numbers will appear in the call window as they are entered If an incorrect master station number is entered press RESET black button and try again 2 Pick up the handset to talk 3 To cancel press the RESET black button or hang up handset at either the calling or called master If the called master station is in communication with another station no visual or audible signals will be generated Try again later If master stations are in communication each can discontinue communications in order to respond to another station by pressing RESET black button Incoming high priority calls automatically cancel master to master communication If medium or low priority calls zoned for a master comes in while master to master communication is taking place the call can be answered by pressing the RESET key and TALK key
127. onfiguration functions scan and view master and remote station configurations and place various types of calls Features will be discussed in greater detail in the System Operating Section The system is completed by a wide range of bedside stations with entertainment control options A variety of emergency stations and a nurse aide presence station are also available Staff stations for utility or examining rooms duty stations and corridor dome zone lights are designed to instantly alert the nursing staff of patients needs Simplified wiring and plug in design provide ease of installa tion in new construction or existing buildings Modular circuits and totally interchangeable room stations permit change or expansion at any time A WORD ABOUT ELECTROSTATIC DISCHARGE What Is It Static electricity is a result of triboelectric charging of two dissimilar non conductive materials that are rubbed together such as rubbing your feet on a carpet on a cold winter day or in a dry climate The resulting charge is detected when you reach out to touch a doorknob or some other metallic object The resulting discharge may be only startling or in severe cases it may even be painful The actual electrical charge is dependent on the materials rubbed together humidity rate of separation and other factors What Can It Do While this effect may be disturbing to humans the effect on electronic equipment is often more serious ranging f
128. onjunction with patient staff and duty station zone assignments Follow the procedure listed below at each master to assign master station zones Note On Main Menu numbers 8 and 9 used on NC350CP SERIES 8 and 9 not present on NC350C 64 A Establish desired zone s 1 8 for each master station B Press CAPTURE blue button to go directly to Master Zone Assignment menu Master Zone Assignment ZONE iw 2 3 4 5 6 7 8 Xa Enter Zone Number To Change Status menu save and edit An X will appear for zone indicating what master is in use Press number 1 8 to remove X Pressing the same number again will cause the to reappear Press 9 on keypad to set all zones MENU appears in call window when zone assignments are being entered Note Default is all zones IL421 Tek MICRO Nurse Call System Manual 15 3 6 MASTER CALL RESPONSE C Select Intercom Preannounce Tones by pressing 2 on keypad Follow the procedure below to assign Master Call Response ITERGOMDPEEANNBUNCE TONES Note On Main Menu numbers 8 and 9 used on NC350CP Tones status ON Series 8 and 9 not present on NC350C 64 i Cn A Press MENU blue button D Press 1 on keypad for desired response MAIN MENU 1 Help Menu 3 8 DS
129. onsists of 1 twisted pair plus 1 conductor 18 gauge stranded wire wrapped by an overall aluminum mylar shield and an Orange PVC 020 thick jacket The shield has a 18 gauge drain wire The conductors are Yellow Orange and Green insulated by 033 thick Tapolene The capacitance between these conductors is 23 pF foot Copyright TekTone Sound amp Signal Mfg Inc All Rights Reserved Audio Assembly consists of 1 twisted pair 18 gauge stranded wire wrapped by an overall aluminum mylar shield and a Gray PVC 020 thick jacket The shield has a 18 gauge drain wire The conductors are Purple and Gray insulated by 015 thick PVC Three 18 gauge stranded wires wrapped by an overall aluminum mylar shield The shield has a 18 gauge drain wire The conductors are Red Brown and Blue insulated by 015 thick PVC One 16 gauge stranded wire The conductor is Black insulated by 016 thick PVC 5 22 selective foreach SF340B SF341B SF337C LI380 in system Run to patient station C 8 22 selective for each LI384A in system D 6cond 22 selective for each SF350B presence station in system Run to patient station E Run RG59U cable from the CPE to each NC310B Video Monitor See notes on BLOCK WIRING DIA GRAM NL402 for additional information Station Wiring Layout Run station wiring in accordance with the following information and notes provided on the BLOCK WIRING DIAGRAM NL402 Wiring may be ru
130. operation by seated or prone patients When used as a pull station locate where access is convenient for both patients and nurses If properly mounted the SF337C is waterproof SE340B Emergency Station The emergency stations should be located where convenient for operation in areas such as toilets baths or showerrooms Avoid areas where direct contact with water may occur The SF340B may be used as a pull station or a pull cord station To use as a pull cord station thread nylon cord through hole provided in the GUIDE tab on lower 6 IL421 Tek MICRO Nurse Call System Manual position of the face plate and red pull down lever Secure with a double knot then mount station high enough for convenient operation by seated or prone patients When used as a pull station locate where access is convenient for both patients and nurses SE341B Code Call Station The CODE call station should be located for convenient operation in areas such as ICU CCU physical therapy rooms post op recovery or any location where code call initiation may be required The centrally located blue pull down lever provides for simple quick CODE calling SF336 SF338 Staff Emergency Psychiatric Station The SF336 SF338 should be mounted within the psychiatric ward or other high security areas where those patients are accommodated and within easy reach of the nursing staff SE350B Nurse Aide Presence Station The nurse aide presence
131. ote When adding or deleting stations new stations are picked up automatically with default address deleted stations must be deleted from the program Data Polling Noise on all stations on one or more ports when in listen from NC303 Check Shield drain wire terminations of field wiring to CPE Please see wiring diagrams for cor rect drain wire connections Excessive Data Polling noise on one or more sta tions when in listen from NC303 Check Shield drain wire terminations at station loca tion and all locations where cable has been cut and spliced Please see wiring diagrams for correct drain wire connections Data Polling Noise at Duty Station IR315B Check System cable length If system cable length exceeds 500 per port connect a 100 uf 25 VDC capacitor across 12VDC blue wire on 8 pin to negative red wire on 8 pin connec tor side of cap to blue wire side of cap to red Duty Station IR315B not responding to calls Check a IR315B zone programming An IR315B will only annunciate calls from stations it is zoned for An IR315B will default to only the zone correspond ing to the port it is connected to LAMP FAULT Check a b Bulbs at LI384A Supervised Dome Light Brown wire on 8 pin connector jumped to blue wire on 15 pin connector MASTER FAULT Check a Correctly addressed master is plugged into appro priate port In multiple master systems master labeled C1 plugs into
132. ower switch located on the right rear side of CPE to ON Do System Test Section 6 0 then configure system as desired DSN Port NC350BP Port Output 3 Master Port Port Output 1 1 lt 4 port Video Port 1 Serial Communications Master Port 4 Master Port 2 mr Fig 4 10 IL421 Tek MICRO Nurse Call System Manual Port Port Output 2 Port Output 4 System Run LED flashing is normal Copyright TekTone Sound amp Signal Mfg Inc All Rights Reserved NC350C Series NC362 RCA jack plugs into adaptor 1 of 4 d Master port 9 plug 1 of 4 master ports CT318 cable Master port cable should match color on 9 pin connector at wall plate supplied with master Maximum distance from CPE to master 200 Fig 5 Tod eui NT OPEN LOW VOLUME A B SHORTED MEDIUM VOLUME SHORTED HIGH VOLUME System Cabling 1 shielded audio Ld J 1 pr shielded data eo NET maie connector e Ld 1cond 16 gt d CT317 cable Wall Plate bd includes 9 pin female e with wire pigtalis gt 4 NC303 Master Station Master cable supplied at 6 with 9 male on end NC310B Video Monitor
133. r call type pear on call screen Room bed ID number appears in call window 2 Room number flashes in NURSE area on call screen Check for following at patient station 1 Dome light green lamp flashing Check for following at associated presence station 1 Light green flashing Check for following at duty station in the same zone 1 Dome light green lamp flashing Press TALK then RESET black function button Check for following at master station 1 Room number still flashing in NURSE area on call screen All other calls canceled Check for following at patient station 1 Dome light green lamp flashing Check for following at associated presence station 1 Light green flashing Check for following at duty station in the same zone 1 Dome light green lamp flashing Cancel nurse service request by selecting room number as for communications then pressing NURSE green button then TALK and RESET black button Check for following at master station 1 signals canceled Request aide service by selecting room number as for communications then pressing AIDE yellow but ton Check for operation same as nurse service request with the following exceptions 1 Room number will flash in AIDE area on call screen 38 IL421 Tek MICRO Nurse Call System Manual 2 Yellow lamp will flash on associated dome light and presence station
134. r valid room numbers then press key If an invalid room number is entered not found re enter will display Up to 10 rooms can be monitored at one time After valid room numbers are entered they will be retained until system is powered down Note Room monitoring will be canceled if call is on display from a room To cancel room monitoring press RESET on Master at any time 3 19 TO PROGRAM PATIENT PRIORITY Note On Main Menu numbers 8 and 9 used on NC350CP Series 8 and 9 not present on NC350C 64 A Press PRIORITY blue button to go directly to Set Room Priority SET ROOM PRIORITY Room amp Bed No 8101 1 Priority Status Routine menu save 1 toggle selection B Enter room and bed number C Select the desired priority by pressing 1 D Press the to save Programmable patient priorities include ROUTINE PERSONAL ATTENTION and PRIORITY The call screen will immediately reflect the change in call type the call will be positioned on the call screen according to the new priority and all other signals will react in accordance with the new priority established A station priority changed to PERSONAL ATTENTION or PRIORITY when communication was established by the patient station will not allow reset from the Master station 20 IL421 Tek MICRO Nurse Call System Manual 320 TO PROGRAM STATION PRIVACY Note On Main Menu numbers 8
135. rger conductor 2 Install nurse call system wiring in metal conduit This conduit may also be used to ground panels The conduit must be electrically continuous and be grounded 3 Use shielded wire in cable for nurse call system station to station wiring The use of open conductors invites inductive coupling of discharge currents which can cause the same problems as direct discharge currents 4 Ground your body before handling system components This can be done using a wrist strap or simply by contacting a grounded surface Use caution to avoid hazardous voltages while grounded What The User Can Do The most common generation of ESD in hospitals is due to changing linen on hospital beds while the patient call cord or pillow speaker is still connected to the nurse call system The following precautions will help 1 Remove the call cord or pillow speaker from the bed before changing It will be necessary for the nursing staff to discharge themselves by contacting a grounded metal object before placing the call cord or pillow speaker back on the bed otherwise a spark will jump to the nurse call equipment causing the very damage they are trying to avoid To avoid a shock while discharging static electricity on the body hold a metal object such as a key and use that object to contact the grounded surface 2 Ground the bed and use antistatic mattress covers in contact with the bed frame For safety it may be desirable to make the ground con
136. rom disrupting the operation to actual damage of the components These effects result from the high voltages that may be developed The simple act of walking across a carpet may develop as much as 30 000 volts changing a bed sheet may create a charge of 100 000 volts or more Such voltages readily cause arcing the spark you see in the dark when you grab the doorknob after walking across the carpet etc The arcing is evidence of a discharge path Due to the high voltage involved the discharge current can jump to any nearby metallic object If the discharge is to or through an electronic device such as the nurse call system the operation of the device may be affected If the discharge current passes through internal components these components may be damaged or their operation degraded What Can We Do About It The manufacturer of the nurse call equipment has already taken steps to protect the equipment from electrostatic discharge ESD effects However since the cause of the problem is not in the equipment but in the environment further measures are required of the installer and the user to achieve complete protection What The Installer Can Do In humid climates or in places where the relative humidity is kept at 65 or greater there will likely be few problems with ESD Where problems may occur the following measures can be taken 1 Ground all exposed metal surfaces such as patient station panels etc Grounding should be to a 16 or la
137. rtime B Select System Function Menu by pressing the 4 on 4 Reconfiguration k d 5 Hook Switch i prev menu select menu item SYSTEM FUNCTIONS ion ine 4 1 Set Time Date C Select Reconfiguration by pressing 4 on keypad Wout Cake 3 Set Overtime RECONFIGURATION 4 Reconfiguration Program Menu 5 Hook Switch Reinit System prev menu select menu item Define Password Set Reset Code Call Add Del Station prev menu select menu item C FO Select Reconfiguration by pressing 4 on keypad RECONFIGURATION Program Menu Reinit System Define Password Set Reset Code Call Add Del Station prev menu select menu item D Select Program Menu by pressing 1 on keypad PROGRAM STATION 1 Program Station 2 Duty Station Call Display 3 Duty Station DSN Zone Capture 4 Program Pager prev menu select menu item D Select Program Menu by pressing 1 on keypad E Select Duty Station Call Display by pressing 2 on PROGRAM STATION keypad 1 Program Station 2 Duty Station Call Display DUTY CALL DISPLAY 3 Duty Station DSN Zone Capture Code Duty 4 Program Pager Fire Staff E prev menu select menu item Emergency Pers Attn Monitor Routine g Bath Stat E Select Duty St
138. s per port Four RCA jacks are available for video monitors Jacks are identified as Video Output 1 2 3 4 A Y adapter is provided for two additional jacks ifnecessary Ports are identified as MASTER PORTS 1 4 and PORT OUTPUTS 1 4 Copyright TekTone Sound amp Signal Mfg Inc All Rights Reserved See Fig 4 for location and identification of CPE ports Connect the 16 gauge system ground wire to the CPE chassis Ground the CPE chassis to a good cold water pipe ground A grounded 3 wire outlet must be available for 115 VAC power supply to CPE DO NOT supply power until all connections to equipment have been checked NC350C 64 Central Processing Equipment The NC350C 64 CPE is the same as the NC350CP cept it has the capacity of up to 64 patient staff or duty stations per system The NC350C 64 also sup ports a maximum of 2 master stations NC303 MASTER STATION The master station cable assembly should be plugged into the wall plate supplied with each master station Run cable from the wall plate to the appropriate cable assembly at the CPE See Fig 5 for details NC310B Video Monitor Plug one end of the RG59U cable with connectors to VIDEO IN jack located in back of the video monitor Plug the other end of the cable to the adapters which connects to the appro priate output card Plug the video monitorinto a grounded outlet supplying 115 VAC No internal wiring is neces sary
139. ssigned to each room number Repeat steps A E section 3 22 and then perform the following A Select Assign Pager to Room by pressing 5 on keypad PAGER ROOM ASSIGNMENTS Room and Bed No menu enter enter room ID Enter a valid room number and ID and then press the All available pagers will be displayed see next menu 22 IL421 Tek MICRO Nurse Call System Manual A Select Execute a Page to a Pager by pressing 6 on keypad PAGER EXECUTION MENU Pager ID Ext abort enter pager no Enter a valid pager ID number and extension the first group of 10 messages will be displayed see next menu PAGER EXECUTION MENU 0 Agonal Rhythm 1 Cardiac Arrhythmia 2 Chest Pain SOB 3 Stat Call 4 Leads off Monitor 5 Replace Battery 6 Call Ext Ext 7 Stat Ext Ext 8 Go to Telemetry Sta 9 Nurse needed at desk Pager ID No 400 select message to send or reset cancel Select the message to send by pressing 0 9 message will be sent immediately If the message that you wish to select is not displayed press to scroll down to the next set of 10 messages or press to scroll up to the previous 10 messages Press RESET to exit or cancel Copyright TekTone Sound amp Signal Mfg Inc All Rights Reserved 4 0 SYSTEM OPERATING INSTRUCTIONS The following section provides comp
140. system Following entry of the currently assigned station num ber the program station menu will appear on the video monitor Currently assigned station number will be highlighted Enter new room number using keypad and observing the following Room numbers must be four digits excluding bed ID number An indication of not found re enter will appear if room number is entered incorrectly Digits may 0 9 A Z in any combination Alpha characters can be programmed by pressing the alpha key and then the letter on the keypad NOTE the alpha key must be pressed before entering each letter If desired the first digit of the room number may be used to identify a specific floor or wing STATION ZONE ASSIGNMENTS Zoning 1 2 3 4 5 6 7 8 X X X X X X X X Room No 8201 Bed 1 1 Bed 2 2 menu enter room id Enter first bed ID number using keypad and observing the following Bed ID numbers may be from 0 9 A Z and must be used for single and dual patient stations When programming bed ID numbers for dual patient stations enter second bed ID number STATION ZONE ASSIGNMENTS Zoning 1 2 3 4 5 6 Y 8 X X X X X X X X Room No 8201 Bed 1 1 Bed 2 2 menu enter bed id Press numbers on keypad to turn zones Press 9 to assign all zones Press key to save and now you are ready to program the next station STATION ZONE ASSIGNMENTS Zoni
141. th circuits should be tested The chart provided for listing assigned room numbers should be filled in at this time Check for following at patient stations 1 Call placed light flashing 2 Dome light white lamp on steady Check for following at master station 1 Call light slowly flashes 2 Tone signal every 8 seconds 3 Callinformation appears on the call screen with the call priority indicated ROUTINE for non emer gency or EMERGENCY for a call from the staff emergency station Check for following at duty station in the same zone 1 Call placed light flashing 2 Tone signal every 8 seconds 3 Dome light white lamp on steady B Test intercom function from master station by pressing TALK white button as previously described C Reset each psychiatric and staff emergency psychiatric station as described in the Systems Operating Section 4 0 page 23 Check for following at psychiatric staff emergency psychiatric duty and master stations 1 All signals canceled 6 4 SF337C SF340B BATH EMERGENCY STATION TEST PROCEDURE A Initiate a call on each emergency station one at a time as described in the System Operating Section 4 0 page 23 1421 Tek MICRO Nurse Call System Manual 39 Check for following at emergency station 1 Call placed light slowly flashing Check for following at associated patient station 1 Call placed light slowly flashing 2 Dome light white lamp
142. tional use only is subjectto change withoutnotice and should notbe construed as a commitmentby TekTone S ound amp Signal Mfg Inc TekTone Sound amp Signal Mfg Inc assumes no responsibility or liability for any errors or inaccuracies that may appear in this documentation TekTone the TekTone logo Tek Call Tek Care Tek Check In Tek Com Tek Digicare Tek Door Tek Entry Tek Guard Tek Micro Tek Micro Tek MMARS Il TekNIOS TekNIOS Tek P aging Tek P hone Tek Safe Tek Selectll Tek Sentry Tek Sound Tek Status Tek Trio and Tek View are either registered trademarks or trademarks of TekTone Sound amp Signal Mfg Inc in the United States and or other countries All other trademarks are the property of their respective owners 1 0 2 0 3 0 TABLE OF CONTENTS 2 1 EQUIPMENT REQUIREMENTS AND APPLICATION 22 24222224 4 2 2 2200000000 0000000005000005000000 3 2 22 EQUIPMENT LOCATION 2 3 WIRING INSTALLATION 2 4 HOUSING INSTALLATION 2 5 WIRE CHECRK OUT ioi ea A a le te Ee et t e e ga dte 2 6 WIRE CONNECTIONS STATION 2242 2 4 0000202010010000000000500000050000000 000000000500 2 7 MASTER STATION SETTINGS AND ADJUSTMENTS 2 6 CONNECTIONS CHECK OUT be e p i yet PEE e SYSTEM CONFIGURATION PROGRAMM ING eeeeee teens enea
143. tive signals as previously described Calls proceed by priority and time of origin A higher priority call will replace a lower priority call by position on the call screen The call window will display the room number with which current communications are established As calls are answered calls waiting if any will appear on the call screen in order of priority If a high or medium priority call is placed while a master station is in communication with another station the TALK function with the current low priority call will only be active for 8 10 seconds then the current call will be placed on hold and the higher priority call will automatically be dropped 421 Tek MICRO Nurse Call System Manual 25 into master box TALK must be pressed to connect audio once the higher priority call is reset the lower priority call is automatically dropped into master box and TALK must be pressed again to connect audio 41 4 PLACE CALL 1 Dial the desired room number on the keypad followed by the key The numbers will appear in the call window as they are entered If BUSY appears in the call window the station or circuit is in use Continue when the BUSY disappears 2 Press the TALK white button or pick up handset If pre announce call tones are ON a one second tone will be heard at master and room station when TALK button is first pressed 3 Press the TALK white butt
144. ult light and waterproof membrane switch NC310B Video Monitor The NC310B Video Monitor pro vides the means for visually tracking all NC300 System activity including display of all types and exact location of calls All calls are displayed in standard English format The NC310B must be used in conjunction with the NC303 Master Station The video monitor is a standard monochrome type with composite video input and minimum of 350 lines of resolution It includes a 12 amber or green screen with power screen contrast and bright ness controls and ON OFF LED indicator IRO19C Speaker Microphone Station 019 provides audio communication when used in conjunction with the IR316 Psy chiatric Station IR300B Multipurpose Station The IR300B Multipurpose Sta tion provides for audible visual and digital communications to and from the central equipment including the nurse master station and video monitor It is used with remote devices such as switches contact closures loudspeakers or other signal origi nating equipment IR300B is mounted ona flame retardant type ABS plastic panel The IR300B can also support a zone lamp Turning DIP switch 7 ON turns IR300B Zone Lamp function ON Use LI380 or LI384A for lamp IR301B Single IR302B Dual Patient Stations The IR301B Single and IR302B Dual Patient Stations provide reliable hands free communication between the patient and the nurse The IR301B provides communicati
145. utton Press TALK or lift handset NOTE Only loca tions that have Nurse or Aide presence indicated will be paged using SF350B Presence Station Enter desired zone number 1 8 on keypad NOTE if no numbers are entered the page will default to the zones programmed for the master in use PAGE will appear in the call window If BUSY appears the zone being paged is in use from another Master in communication Press TALK white button while speaking or pick up handset ENABLE ROOM MONITORING 1 Press MONITOR blue button or select Room Monitoring by pressing 6 on the keypad If room numbers given are correct press TALK If room numbers are not correct enter valid room numbers then press key If invalid room num ber is entered display will show not found re enter If wrong number is entered enter the correct one or press to clear the number Up to 10 rooms can be monitored at one time Call displayed cancels monitor 421 Tek MICRO Nurse Call System Manual 27 4 1 16 4 1 17 4 1 18 TO USE NURSE AIDE FOLLOWER 1 Make sure there are no calls waiting then press the NURSE AIDE FOLLOWER orange button Call tones will be sent to any room in the system where a nurse is registered provided the master is zoned for those calls 2 To send call tones to a specific room select the room as for communications then press the NURSE
146. video display The NC310B may be desk mounted in a location which provides for easy access to a grounded 117 VAC outlet and unobstructed visibil ity Each video monitor is supplied with 2 RCA type phono connectors to be added to RG59U cable at both ends Connector adapters allow for connection of RCA type connectors to the adapters located on the video output ofthe NC350C 64 CPE and Video In jack on the NC310B Video Monitor The operating temperature range of 10 C 30 C should not be exceeded Call Cords The call cord plugs should be inserted into associ ated station jacks or receptacles IR Series Patient Stations The patient stations should be located where convenient for operation most commonly at the head of the patient s bed The operating temperature range of 10 C 40 C should not be exceeded IRO19C Speaker Microphone Station The IRO19C should be located where audible The IRO19C is designed for use in high security areas such as psychiatric wards It is flush mounted normally in the ceiling or out of psychiatric patient s reach The IRO19C should be located in conjunction with the IR316 IR300B Multipurpose Station The multipurpose station should be centrally located in regard to the remotely mounted initiation devices switches contact closures loudspeakers or other sig nal originating equipment with which itis used No controls are provided The operating temperature range of 10 40
147. y to reuse the label Should the user wish to label a room with a label not on the standard list they must use the menus presented in Section 2 3 below that allow the user to program a unique label for that room The key sequence needed to access Figure 6 and Figure 7 menu is as follows Press MENU Select 4 from Main Menu Select 4 from System Function Menu Select 7 from Reconfiguration Menu Select the number of the label to change refer to the menu shown in Figure 6 Press ALPHA and type new label 5 character limit 7 Press key to save esso port Create Standard Label Menu Figure 7 CHANGE LABEL 1 NORTH 6 TUB 11 LUNCH 16 ICU 2 SOUTH 7 SHWR 12 KITCH 17 THRPY 3 EAST 8 REHAB 13 LINEN 18 OR 4 WEST 9 PSYCH 14 STAIR 19 ER 5 PUBLC 10 LOUNG 15 DOOR 20 LAB LABEL 20 save edit label 2 3 Assigning Room Numbers and Labels To program the label of a specific room number the procedure is as follows Enter the Reconfiguration Menu as shown in Figure 3 page 51 Select option 1 Program Menu select option Program Station Station Zone Assignments Menu Figure 8 STATION ZONE ASSIGNMENTS ZONE 172 33 45 2570 1538 Room Label menu enter enter room id Enter the desired room number and bed ID using the keypad After doing so Figure 9 is displayed3 as follows Figure

Download Pdf Manuals

image

Related Search

Related Contents

Degreaser  Samsung Corby II Black Kullanıcı Klavuzu  Avaya Connecting BayStack AN and ANH Platforms to a Network User's Manual  Guía del usuario de HP MINI  Rabot de coupe à angle faible et rabot de coupe standard  Western District of Missouri Chapter 13 Plan  Oregon™ 550/550t  IR8001 T6000 FOO interno.qxd  Wilo-Stratos/-D/-Z/-ZD  Partner Tech P11577H User's Manual  