Home

Pilot-Operated Safety Relief Valves - Comsert

image

Contents

1. Solid C Split Back Flow Preventor Direct Sensing Remote Sensing Standard Stainless Steel NACE Buna Viton Other Soft L SS Hard Peek In service Test Kit L Manual Blowdown Valve Remote Unloader C Pilot Filter L Dome Spring L HL Modulating 396 to 596 Fixed Blowdown Teflon MEASUREMENT SYSTEMS Relief Valve Order Form GENERAL INFORMATION Company Name Customer Name Date Tag Number Service Quantity ISERVICE CONDITIONS Set Pressure Service Vessel Number Fluid Type amp State VALVE SELECTION Model L HF Snap Acting 5 to 7 Fixed Blowdown LJ HL Modulating 3 to 5 Fixed Blowdown Part Number Inlet Size amp Rating Outlet Size amp Rating Orifice OPTIONS Piston Type Solid C Split Back Flow Preventor Hook up Type Direct Sensing Remote Sensing Trim Standard C Stainless Steel NACE Seal Material Buna C Viton Other Seat Type Soft SS Hard Peek Teflon Other In service Test Kit Manual Blowdown Valve Remote Unloader Pilot Filter Dome Spring MISCELLANEOUS Additional Information Xylan is a registered trademark of Whitford Corporation MEASUREMENT SYSTEMS Formerly NuFlo Measurement Systems Barton Instrument Systems Caldon Inc NORTH ASIA EUROPE MIDDLE EAST AMERICA PACIFIC amp AFRICA 1 800
2. G TENE ADJUSTING CAP 53 3 SPRING LOCKNUT SENSING PISTON CN for the pilot spring to y ar shift the pilot into its p ag iu Td e pee flowing position ABOVE Split Piston Separated The split piston is recommended for installations where a manifold discharge system serves a number of relief valves If a manifolded relief valve is out of service when one or more other valves exhausts into the common discharge system the split piston separates and prevents backflow through the out of service valve SOOO SYSTEMS Installation Schematics Types HF Type HL Direct Hookup Relief valves configured for direct operation are equipped with an internal pressure pickup tube stinger in the throat of the valve inlet They are factory shipped as self contained assemblies ready for installation Remote Hookup Relief valves configured for remote operation do not contain an integral pressure pickup connection Pressure is sensed from a remote point on the vessel process line through a single tube connected to the header block located on the valve PILOT S lt zz lt 5 m o4 6 x Pipe Dia TYPE HL TYPE HL FIRE RELIEF VALVE TYPEHL RELIEF VALVE BY CUSTOMER ne e n e d uns I lt a SE VALVE VESSEL tr lu a F ie i 2 BSS io d BLOCK P pu VALVE m im 1 a HAND lt m RELIEF VALVE PILOT
3. rises the force against the piston seal increases HF HL Loaded Valve Yes Yes No Yes Yes Yes Yes Yes No Yes Yes No Yes Yes No Yes Yes No Yes Yes No Yes Yes No No Yes No Yes Yes No Yes Yes No No Yes No the overpressure volume of gas vapor and or liquid Applications include oil and gas production systems compressor stations gas transmission pipelines facilities storage systems distribution systems and in all types of processing plants Then when the system pressure reaches the relief valve discharge set pressure the pilot cuts off system pressure and opens the top of the piston to vent pressure As the pressure above the piston is relieved the relief valve opens discharging line pressure When the predetermined blowdown pressure is reached the pilot shuts off the exhaust and re opens the flow of system pressure to the top of the piston effectively closing the relief valve Operation Type HF Relief Valve Closed At below set point the normally open combination pilot allows system pressure to enter the piston housing cavity of the relief valve on top of the free floating piston The top of the relief valve piston has a larger area than the valve seat where the piston seals Equal pressure at both ends of the piston creates a differential downward force which holds the piston tightly closed on the valve seat Below Type HF relief valve closed po
4. 654 3760 65 6737 0444 44 1243 826741 ms us Q c a m com ms asiapacific c a m com ms uk c a m com HOUSTON HEAD OFFICE 281 582 9500 www c a m com flo RV RVALVE NF00033 0701 MEASUREMENT SYSTEMS USA Houston TX e Corpus Christi TX e Kilgore TX e Odessa TX e Dallas TX e Tulsa OK Duncan OK Denver CO Bakersfield CA Shreveport LA Lafayette LA Houma LA e Pittsburgh PA e Laurel MS e Dunbar WV e Casper WY e Charleston WV CANADA Calgary AB e Edmonton AB INTERNATIONAL Aberdeen Scotland Beijing China e Bognor Regis UK Dubai UAE e Hassi Messaoud Algeria e Kuala Lumpur Malaysia e Singapore C CAMERON
5. Orifice 316 SS 316 SS 316 SS 316 SS 316 SS 316 55 316 55 316 SS Header Block CS 316 SS CS 316 SS 316 SS 316 SS CS 3 316 SS Pilot Valve 316 SS 316 SS 316 55 316 SS 316 SS 31655 31655 316 SS Notes 1 A 216 Gr WCB 2 A 351 Gr CF8M 3 HRc 22 maximum E Soft Seat Service Material Buna N Viton Teflon Peek S S Sizing Order Form GENERAL INFORMATION Company Name Customer Name Date Tag Number Service Quantity INPUT DATA Continuous Temperature F Maximum Minimum 2 5 65 400 65 400 423 480 423 Minimum Pressure psi Pilot Main 15 15 15 15 60 1500 1500 Maximum Pressure psi Pilot Main 6000 1500 6000 1500 1500 3000 6000 A relief valves primary purpose is to protect lives and property It is imperative that the proper valve be selected for your application To assure that the proper valve is selected please fill out the Order or Sizing Order Form and consult your NuFlo representative for assistance Specific Gravity Mol Weight Ratio of Specific Heats K Compressibility Factor Z Required Capacity Set Pressure Relief Temperature Allowable Overpressure Back Pressure Fluid Type amp State OPTIONS Model Piston Type Hook up Type Trim Seal Material Seat Type Other MISCELLANEOUS Additional Information HF Snap Acting 596 to 796 Fixed Blowdown
6. MEASUREMENT SYSTEMS NUFLO Pilot Operated Safety Relief Valves Series H In the mid 1940s a new relief valve actuated with a pilot rather than a spring set a new standard for pressure control The valve manufactured over the years by companies like Full Flow Capacity Garrett USI and Axelson is now manufactured and sold by NuFlo Measurement Systems Backtlow Protection NuFlo s pilot operated pressure relief valves are an example of a tradition of advanced design and high quality manufacturing abilities These valves offer advantages not found in other relief valves spring or pilot operated Non Flowing Pilots Simple Maintenance Coated Bodies Easier Handling Valve Types Type HF This is a full lift pop action valve with a fixed 5 to 7 blowdown using a single non flowing pilot This type of valve is designed for gas and or vapor service and is offered in sizes of 1 through 8 with operating pressures ranging from 20 psig to 6000 psig Advantages Full Flow Capacity In addition to the various API orifice sizes NuFlo offers valves with non standard API orifice sizes for maximum flow capacity and smoother operation Many times this allows for the use of smaller size valves at a cost savings to the customer Backflow Protection The unique NuFlo split piston optional is designed to eliminate the effect of pressure in the discharge system back flowing into a relief valve on installations wher
7. S TYPE HL TYPE HL PILOT RELIEF VALVE TYPE HL as r Oo TYPE HL RELIEF VALVE BY CUSTOMER N 6 x Pipe Dia Ta ee MEASUREMENT SYSTEMS Orifice Selection Available Orifice Sizes for Type HF and HL Pilot Operated Relief Valves Valve Coefficient 0 859 gas 0 674 liquid Valve Size Outlet Orifice Orifice Area Sq In Valve Size Outlet Orifice Orifice Area Sq In I cz Single D 0 110 3 x4 Single J 1 287 E 0 196 K 1 838 F 0 307 L 2 853 G 0 503 M 3 600 GX 0 652 N 4 340 1 0 785 P 6 380 1 1 2 x 2 Single D 0 110 3 7 068 E 0 196 4 x6 Single Dual L 2 853 F 0 307 M 3 600 G 0 503 N 4 340 H 0 785 P 6 380 1 257 4 12 566 JX 1 633 B xS Single Dual Q 11 045 1 1 2 1 767 R 16 000 1 1 2 x 3 Single G 0 503 T 26 000 H 0 785 6 28 270 J 1 287 8 x8 Dual Q 11 045 JX 1 633 R 16 000 1 1 2 1 767 T 26 000 PS do Single G 0 503 7 38 484 H 0 785 7 1 2 44 178 J 1 287 8 x 10 Single Dual Q 11 045 JX 1 633 R 16 000 K 1 838 T 26 000 KX 2 776 2 38 484 2 3 141 7 1 2 44 178 Trims Available Materials of Construction Standard Stainless Steel Full Stainless Steel NACE HF HL HF HL HF HL HF HL Body CS 1 CS 1 CS 1 CS 1 S8 2 SS 2 CS 1 3 CS 1 3 Piston Housing CS 1 CS 1 CS 1 CS 1 SS 2 SS 2 CS 1 3 CS 1 3 Piston AL AL 316 SS 31655 316 S5 31655 316 SS 316 55 Valve Seat 316 SS 316 SS 316 55 316 SS 316 55 31655 316 55 316 SS
8. a single combination control with a fixed blowdown for controlling relief valve opening and closing pressure set points The opening set pressure is determined by the force of a control spring which holds the relief control section of the valve closed When system pressure acting on the relief control valve seat area equals the spring force the relief control opens and the blowdown control section closes blocking system pressure from passing into the chamber above the main valve piston As the relief control opens the pressure underneath the control seat is exposed to a larger pressure area which provides snap action of the control pilot to quickly reduce pressure in the piston dome COMBINATION This pressure reduction PILOT E causes the main valve LA piston to lift relieving ADJUSTMENT 1 mes system pressure j spams E After the system we _ STEM pressure is reduced to a point whereby the FETA E control valve spring Locknut ii Mee E forces the blowdown control ball to unseat the relief control valve closes and the open ZI L EE CITAR EXHAUST Eag blowdown control valve IE 4 aa Se allows system pressure PUSH ROD to re enter the piston dome forcing the main piston down to a closed valve position BALL SEAL SENSING PRESSURE INLET Function of the Split Piston Normal Piston Position All NuFlo pilot operated pressure relief valves can be ordere
9. als Equal pressure at both ends of the piston creates a differential downward force which holds the piston tightly closed on the valve seat Below Type HL relief valve closed position Relief Valve Open When system pressure reaches the set point the pilot piston forces the pilot stem upward by compressing the pilot valve spring This movement of the stem simultaneously blocks the system pressure passageway through the pilot and commences the bleeding of pressure from the relief valve piston housing cavity Decreasing pressure on the top of the relief valve piston allows system allows the valve to open relieving system overpressure As system pressure drops below the blowdown reset point system pressure re enters the relief valve piston cavity closing the relief valve Right Type HL relief valve relieving position MEASUREMENT SYSTEMS Type HL Relief Valve j LIFTING EYE PISTON au HOUSING BE a e Var OPTIONAL FM A SOLID or SPLIT E wow PISTON m Solid Piston Shown DISCHARGE HEADER BLOCK PILOT SENSING d PRESSURE PICK UP OF HOMAL SOFT or HARD b SEAL BODY INLET Soft Seal Shown gt 4 b es j SiC ta L1 i a 4 I ee In Service Testing and Pilot Setting Options All NuFlo pilot operated pressure relief valves may be ordered with an In Service Test Kit The procedures for the use of this In Service Kit are shown below T
10. d with the exclusive NuFlo split piston This piston is designed to eliminate the effect of back pressure imposed on the discharge side of the valve HL PILOT HEADER BLOCK MEASUREMENT The Type HL pilot is a single control pilot with a fixed blowdown for controlling the opening and closing of the relief valve Opening and closing pressures are determined by the force of a pilot control spring System pressure is applied to the pilot control piston and also to the pilot inlet Hi port The lifting force produced by the pressure on the control piston is reacted by the opposing force of the pilot spring When the spring force is greater than the pressure force of the control piston system pressure is communicated through the inlet Hi port of the pilot to the top of the relief valve piston Since the area on top of the relief valve piston is greater than the seat area the valve is held in the closed position As pressure increases above the set point the force of the control piston becomes greater than the reacting spring force This unbalanced condition shifts the pilot stem upward blocking the pressure coming into the inlet Hi port and allowing the pressure above the relief valve piston to bleed off As the pressure force which holds the piston on the seat decreases the relief valve opens If system pressure continues to rise the piston lifts fully and remains open until system pressure is reduced sufficiently
11. e several valves discharge into a common manifold Simple Maintenance All maintenance including changing the valve seat can be performed using ordinary hand tools without removing the valve from the installation Non Flowing Pilots NuFlo non flowing pilots reduce the problems of freeze up caused by the pressure drop through the flowing type pilots Coated Bodies The bodies and piston housings of all NuFlo pilot operated safety relief valves are internally and externally coated with Xylan for corrosion protection and lubricity Easier Handling A lifting eye is conveniently located on the center of the valve for ease of handling during installation or removal Type HL This is a modulating valve with a fixed 396 to 596 blowdown using a single non flowing pilot This valve is designed for gas vapor and or liquid service and is offered in sizes of 1 through 8 with operating pressures ranging from 15 psig to 1500 psig Features Soft or Hard Seat Seals Soft or hard seat seals are available for a variety of service conditions and applications Soft seat seals are recommended for discharge set pressures of 25 psi to 1500 psi Hard seat seals are recommended for discharge set pressures above 1500 psi Variable Flange Dimensions Flange dimensions can be modified on special order to fit most existing installations This permits NuFlo pilot operated safety relief valves to be used as replacements for older spring loaded val
12. sition r COMBINATION PILOT Relief Valve Open When system pressure reaches the set point the pilot piston is lifted off the valve seat The blowdown seat seals off incoming line pressure causing the exhaust port to open and bleed pressure from the relief valve piston cavity Decreasing pressure on the top of the relief valve piston allows the valve to open relieving system overpressure As system pressure drops below the blowdown reset point the blowdown seat opens reseating the pilot piston which causes the exhaust port to close System pressure re enters the relief valve piston cavity closing the relief valve Right Type HF relief valve relieving position Type HF Relief Valve Fixed Blowdown 5 796 COMBINATION PILOT LIFTING EYE PISTON grat HOUSING B b j E ad ud OPTIONAL IPM AMD SOLID or SPLIT ES PISTON Solid Piston Shown HEADER BLOCK DISCHARGE PILOT 7 E X SENSING B F PRESSURE E X PICK UP AE 3M OPTIONAL E ED E BAM VALVE t I i E i SOFT or HARD BODY SEAL INLET Soft Seal Shown High Pressure Operation Type HL Relief Valve Closed At below set point the normally open Type HL pilot allows system pressure to enter the piston housing cavity of the relief valve on top of the free floating piston The top of the relief valve piston has a larger area than the valve seat where the piston se
13. valve when working on line Combines functions of blowdown and safety valves Saves cost of additional valves and piping Higher capacity per valve size Field test of pilot set pressure Set pressure can be checked or changed with valve still in service Can be used with solenoid valve For electric or pneumatic interface Coated internally and externally Bodies and piston housings Xylan coated for corrosion protection and lubricity Balanced pilot Allows venting into discharge system without effect of back pressure Application A pilot operated pressure relief valve according to the 1992 ASME Code Section VIII Division 1 Section UG 126 is a pressure relief valve in which the major relieving device is combined with and is controlled by a self actuated auxiliary pressure relief valve NuFlo pilot operated pressure relief valves are designed to be used wherever there is a need to exhaust Valve Operation NuFlo pilot operated safety relief valves operate on the principle of unequal areas exposed to the same pressure When the relief valve is closed system pressure pushes upwards against the piston seat seal on an area equal to the inside diameter of the seat Simultaneously the same system pressure passes through the pilot exerting a downward force on the piston acting on an area approximately 5096 greater than the inside diameter of the seat The resulting differential force holds the valve tightly closed As the system pressure
14. ves A and C 7 Open vent valve B 8 Disconnect pressure hose from field test valve A NOTE For additional information on In Service testing refer to the service manual or technical data sheets for this product When a relief valve is not equipped with the In Service Test Kit a Relief and Blowdown test fixture can be used to check or change valve set and blowdown pressures in field shops Only the pilots need to be removed from the relief valve and it is not necessary to remove the valve itself from the installation The operation of this portable test fixture is simple and convenient CAUTION Never use oxygen as a pressure source Pressure from a cylinder of nitrogen or some other pressure source NOT OXYGEN may be used to check the setting or to reset the pressure at which the relief valve will operate Special training is not required and complete instructions are furnished with each fixture The test fixture may be ordered with optional needle valves and adapters for any type of pilot TYPE HL PILOT TYPE HL z RELIEF VALVE Ps SCREEN PLUG FITTING Installed When Used For Gas Service l __ HEADER BLOCK e m IN SERVICE TEST phan TEST BLOCK VALVE B a GAUGE NITROGEN BOTTLE OR HAND VENT VALVE A PET TE rdi i _ i Hook up To Be Furnished By Customar Sa X Pilot Construction The Type HF pilot is
15. ves which may not conform to new safety standards In Service Test Kit This optional feature allows checking or changing the pilot set pressure in the field with the valve in service Manual Blowdown This optional device which allows manual blowdown of the system can also be controlled from a remote location Direct or Remote Control Depending on the application the operation of the NuFlo pilot operated safety relief valve may be controlled directly from the point of installation or remotely No Simmer NuFlo pilot operated safety relief valves are designed to eliminate simmer at the valve seat They do not require percent accumulation or over pressure to operate Special Flanges NuFlo pilot operated safety relief valves can be supplied with special flanges such as Graylock Taper Lok Lenz etc Advantages and Features Easy and economical to maintain All maintenance can be performed without removing valve from line Replaceable soft seat Saves costly lapping of valve seat Operates without simmer at valve seat MEASUREMENT SYSTEMS NuFlo Pilot Operated Competitive Spring Can be set close to system operating pressure Unaffected by vibration of pulsation Block and bleed pilot as standard Reduces freeze ups caused by pressure drop through flowing type pilots Accurate setting with small volume of pressure Test fixture available for fast accurate setting Backflow protection Prevents flow of gas back through
16. ype HF In Service Testing of Pilot Set Pressure CAUTION Never use oxygen as a pressure source Pressure from a cylinder of nitrogen or some other pressure source NOT OXYGEN may be used to check the setting or to reset the pressure at which the relief valve will operate 1 Connect pressure hose from nitrogen bottle to field test valve A 2 Close vent valve B 3 Open field test valve A 4 Slowly open block valve C permitting test pressure to increase to valve set point RELIEF VALVE Et ir i HOOK UP TO BE FURNISHED BY PRESSURE HOSE CUSTOMER la FIELD TEST VALVE A ee ee as TEST GAUGE Fi BLOCK VALVE C R a a a a a e a a a a e a a a a a CHECK VALVE Type HL Typical Direct Hook Up with In Service Test Valve Gas Service Only 1 Connect pressure hose from nitrogen bottle or hydraulic hand pump to test port of header block 2 Close vent valve A UJ Slowly open block valve B or operate hydraulic hand pump permitting test pressure to increase to valve set point Observe set pressure on test gauge and record Close valve B or release pressure on hand pump Open vent valve A NO Ww Disconnect pressure hose from test port NOTE For additional information on In Service testing refer to the service manual or technical data sheets for this product 5 Observe set pressure on test gauge and record 6 Close val