Home

Service Manual PM-200

image

Contents

1. 4 001 004 Repair hit 126 025 7 FOOT CONTROL 126 000 Nah ae eS as 22
2. Service Manual PM 200 2 HP Manual Control 900 008 Installation 1 PM 200 Place the shipping carton in the desired location Remove the unit from the shipping carton Cut out a 5 1 2 x 1 3 4 hole in the panel or wall for the unit Insert the umbilical tubing in first and follow with the unit Place the faceplate flush against the panel level and secure the unit with 4 screws Mount the holder bar with holders below the unit faceplate NOTE This unit requires a regulated air and water supply Filters are highly recommended Install optional master valve assemblies with filter and regulator onto the manual shut off valves Pressures are preset at the factory 80 psi air 40 psi water Connect the supply tubings to the appropriate air and water supply lines Final Check air pressure adjust to 80 psi if necessary Adjt istments Check water pressure adjust to 40 psi if necessary Test handpieces for proper function Test syringe for proper pressure and function 800 237 2303 4 503 538 8756 4 503 538 2845 Fax 4 www beaverstatedental com 1 PM 200 peration 1 The handpiece is activated by selecting either the HI or LO toggle switch located on the right side of the faceplate 4 Depress the foot control to activate each handpiece Pressure is shown on the gauge for the handpiece being used 5 Individual handpiece pressure adjustments are located on the flow control block inside the unit Remove the unit to
3. access the flow handpiece adjustment block To adjust the pressure to each handpiece a Turn adjustment screw clockwise to decrease the handpiece pressure b Turn adjustment screw counter clockwise to increase the handpiece pressure CAUTION A When adjusting the handpiece pressure do not over tighten the screws Damage may result 6 Handpiece coolant water can be turned on or off with the toggle switch located on the left side of the faceplate 7 Water coolant flow adjustment is located to the right of the water coolant toggle switch Handpiece Water Flow Control Knob HI LO Switch Handpiece Coolant Toggle Switch Control Panel PM 200 800 237 2303 4 503 538 8756 4 503 538 2845 Fax www beaverstatedental com Troubleshooting mptom Possible Causes mptom mptom mptom 800 237 2303 4 Handpiece lacks power Improper supply pressure from compressor 80 psi Check handpiece pressure adjustment on unit Air filter may be plugged Pinched supply tubing Defective handpiece gasket at connection with tubing Defective handpiece nmoow Water coolant does not shut off when foot control is released A Adjust air pressure to 80 psi water pressure to 40 psi B Foot control is not exhausting C Defective water relay valve More than one handpiece is operating A Handpiece is not all the way in the holder B Improper adjustment on pilot valve in the handpiece holder C Defective shuttle v
4. alve to gauge Insufficient water coolant Adjust coolant flow valve Water filter may be plugged Handpiece may be plugged Pinched supply tubing Improper adjustment of water relay valve moon Water coolant is running from handpiece while in the holder A Water pressure too high B Air pressure too low C Handpiece holder out of adjustment Water coolant is running continuously Purge switch is on on applicable systems Water pressure to high Handpiece holder out of adjustment Defective water relay valve vom 503 538 8756 4 503 538 2845 Fax 4 www beaverstatedental com ITEM PART DESCRIPTION PART NUMBER QTY ITEM PART DESCRIPTION PART NUMBER QTY ITEM PART DESCRIPTION PART NUMBER QTY 1 Plastic Elbow 1 8 022 038 2 9 Faceplate 101 028 1 17 Plastic Washer 1 4 003 001 Handpiece Adjustment Block 113 021 1 10 Routing Valve 014 006 18 4 way Cross 023 008 Screw 10 32 x 3 8 001 070 11 Needle Vlave 121 000 19 Barb 10 30x 1 16 022 009 Chassis 101 071 12 2 way Toggle Valve 120 000 20 Ferrule 1 8 117 007 Plastic Elbow 1 16 022 039 13 Universal Handpiece Holder 141 023 21 Plug 10 32 si 026 003 14 Holder Bar 1 2 141 052 22 Shuttle Vlave u 002 017 15 Ferrule 1 4 117 008 23 Plastic Tee 1 8 x 1 16 x 1 8 Waher Flat 6 003 032 16 Barb 10 30 x 1 8 022 010 24 Water Relay 25 Syringe MANUAL HANDPIECE CONTROL 4 PM 200 Water In Water Out Air In W
5. ater Relay Valve 123 000 ITEM PART DESCRIPTION PART NUMBER QTY Cartridge Body Assembly 123 018 1 Set Screw 4 40 x 5 8 Body Screw 6 x 1 2 Barb 10 32 x 1 16 Plastic Washer 1 4 O Ring 002 O Ring 001 SBN os aoooho gt so gt oo 5 NON RETRACTION WATER RELAY VALVE 123 000 Quick disconnect Syringe Tip Assembly 113 230 Remove the existing hex nut A hex nut wrench has been provided Remove the syringe tip adapter using the hex wrench Insert the new syringe tip adapter into the syringe head and tighten using the hex wrench Place the two 2 O Rings into the syringe tip nut Screw the syringe tip nut onto the syringe tip adapter and tighten using the hex wrench Push the syringe tip into the syringe tip nut until it snaps into place Replace Syringe Tip 1 Pull the dirty syringe tip out and insert a clean syringe tip into the syringe tip nut until it snaps into place ITEM PART DESCRIPTION PARTNUMBER QTY N3SLONDARWONA Syringe Tip Syringe Tip Nut O Ring 006 O Ring 228 040 Syringe Tip Adapter O Ring 003 Syringe Head Syringe Button Repair Kit Pin Syringe Cartridge Plastic Washer 8 32 Barb 8 32 x 1 16 Syringe Handle SNNaNaaaxaNaa 3 WAY IC SYRINGE 113 400 ITEM PART DESCRIPTION PART NUMBER QTY 1 017 012 126 005 126 004 126 006 O Ring 013 Baseplate A Screw 4 40 x 1 4 001 005 Rubber Pad 126 007 Screw 6 32 x 1

Download Pdf Manuals

image

Related Search

Related Contents

  ICC ICMPP024U6 patch panel  Samsung ML-3310ND manual do usuário  Manuale - Seagate  取扱説明書 - 手すりをつけよう!  NORD – PAS-DE-CALAIS  Manual da Cyber-shot  USER MANUAL - Hatteland Display AS  Genius DVR-FHD650  Craftsman 4-Drawer Service Parts  

Copyright © All rights reserved.
Failed to retrieve file