Home
2 - KUBOTA Centrifuges
Contents
1. ISO CERTIFIED KUBOTA MFG CORP Compact Size of Table Top Centrifuge with Swing Bucket Rotor Plate Rotor amp Fixed Angle Rotor This centrifuge can mount Swing Bucket Rotor Plate Rotor amp Fixed Angle Rotor 68x10mL blood collecting tubes 15mL glass tubes can be centrifuged n the case of ST 410M Swing Bucket Rotor the sealing cap is available for the bio hazard proof Plate Rotor can eliminate dye terminator w hen used with the MultiScreen manufactured supplied by Millipore Corporation Easy to use and convenient functions Program memories 3 channels for repeated routine operation A memory function is available for repetitive operations using the same set values of operation i e speed and time Once the set values are stored in the memory simply pressing the M EMORY key enables repetition of the operation once the samples are loaded e RCF xg set operation function Not only speed but also RCF set function are available In the case where the protocol is specified by RCF the operation conditions are easily set up Buzzer and melody at the end of operation 4 different melodies and one buzzer sound allow recognition of the end of specific operations in the case where two to five centrifuges are in operation Acceleration and deceleration curve can be varied in three steps according to the type of sample and the experimental conditions Compliance with GMP requirements Equipped with
2. Copyright O 2006 KUBOTA CORPORATION G1 Printed in Japan
3. Speed RCF Time Acceleration amp Deceleration 3 channel memories Alarm display Lid open Imbalance Over speed Rotor set abnormality Function for detecting an occurrence of electrical abnormality in motor inverter lid interlock and speed sensor Acceleration Deceleration e Three level selectors Rapid Slow Super slow Speed setting From 300 to 8 000rpm 10rpm increments Speed indication e Digital display From O to 8 300rpm 10rpm increments RCF setting From 100 to 5 870xg different by rotor 10xg increments RCF indication e Digital display From 0 to 6 320xg different by rotor 10xg increments Timer setting and indication Digital display with Hold from 1 min to 99 min in 1 min increment setting and indication Power requirements e Single phase AC100V 10 115V 10 50 60Hz 15A Single phase AC220V 10 230V 10 50 60Hz 10A Rated voltage and Rated current e 100 115V 6 6A 220 230V 3 4A Power consumption and Heat output 470W 1 7MJ h Dimensions weight 44 W x 52 D x 35 H cm 48kg Test standard e Manufactured and tested in accordance with IEC 61010 2 020 1 Those of projections are not included All specifications and external appearance subject to change without notice On Model 5220 only use KUBOTA made rotor adapter and tube rack Do not attempt use rotors adapters or tube racks made by other manufacturers The rotor mentioned in the catalogue is usable on other KUBOTA centrifuge models For d
4. a tachometer port Actual rotor speed is easy to check Safety pursued The various alarm detector sensors secure operation When the alarm is detected the operation stops e The operation stops when a rotor setup condition sensor detects that a rotor is not properly set on the drive shaft e 5220 conforms to the International Safety Standard IEC 61010 2 020 _ Two hooks are provided on the right and left sides of the lid to prevent debris of the rotor from coming off should it be broken during operation F4 5 Acceleration deceleration characteristics graph rpm Speed Rapid deceleration Slow deceleration Super slow deceleration Natural deceleration Super slow acceleration Slow acceleration Rapid acceleration Time Forthe super slow deceleration a characteristic change over speed N can be set from the maximum speed to 0 rpm Natural deceleration starts at the change over speed N Acceleration and or deceleration commencement speed can be selected for the sample easy to stir Density gradient method is also possible ST 720M Swing Bucket Rotor ST 410M Swing Bucket Rotor with sealing cap S17111 Sealing Cap Code No S17111 optional Rotor Bucket and Tube Rack Table for 5220 Maximum Maximum Bucket Tube Rack Tube size mm Speed RCF Adaptor Rotor Name Nominal Capacity diam x length rpm xg rere SENO rere CANO Swinging
5. Bucket Rotor 80x2mL 9 5 11x36 42 3 500 2 290 053 5820 055 4800 96x1 8mL sample cup 17x38 3 500 2 040 053 5820 055 4940 96xRIA tube 10 12x700 95 3 500 2 190 053 5820 055 4730 80x10mL 120 14x700 95 3 500 2 260 053 5820 055 4740 48x10mL blood collecting tube 15mL 150 17 2x750 110 3 500 2 350 053 5820 055 4750 68x7mL blood collecting tube 12 5 13 5x75 110 3 500 2 300 053 5840 055 0260 68x10mL blood collecting tube 15mL 150 17 2x750 110 3 500 2 300 053 5840 ST 720M 28x15mL conical tube 17x121 3 500 2 300 053 5840 32x15mL conical tube 17x121 3 500 2 330 053 5820 055 4780 8x50mL 270 36 4x85 110 3 500 2 330 053 5820 055 4760 16x50mL conical tube 30x117 3 500 2 330 053 5820 055 6070 4x100mL 38 46 5x75 120 3 500 2 330 053 5820 055 4770 4x175mL conical tube 1 61x118 3 500 2 330 053 5820 055 4850 4x200mL conical tube 1 61x130 3 500 2 330 053 5820 055 4850 4x225mL conical tube 1 61x137 3 500 2 330 053 5820 055 4850 4x250mL 60 61 8x100 130 3 500 2 380 053 5820 055 4850 48x2mL 10 7x42 4 000 2 670 attached to rotor 17008 48x5mL 12 5x75 4 000 2 670 attached to rotor 517006 48x7mL 12 12 5x100 112 4 000 2 670 attached to rotor S17007 28x7ML blood collecting tube 12 50 3x75 106 4 000 2 670 attached to rotor S17027 12x15mL conical tube 2 16 5x120 6 4 000 2 670 attached to rotor S17019 ST 410M 12x15mL conical tube 2 16 5x120 6 4 000 2 860 13130 28
6. Code No 352076 and requires a cushion Code No 352090 200mL conical tube is made by Nalge Nunc Code No 376813 and requires a cushion adaptor Code No 377585 225mL conical tube is made by FALCON Code No 352075 and requires a cushion Code No 352090 2 Sealing cap cannot be mounted with 817019 tube rack In the case of 12x15mL conical tube bucket 813130 a sealing cap Code S17111 can be mounted 3 Bio hazard proof sealing adaptors for 50mL conical tubes Code No 055 5760 and for 15mL conical tubes Code No 055 5750 are available 4 15mL glass tubes can be accommodated with an adaptor Code No 055 7400 The optional cushion Code No 024 1400 is required 5 15mL conical tubes can be accommodated with an adaptor Code No 055 1280 6 Before centrifuging check the strength of the plate as the bottom plate may be damaged 7 This tray is convenient for taking out the plate vable at 121 C N s Autoclavable at 121 C Autocla ST 480M PT 20M 21M PT 89M Plate Rotor AT 360M AT 2018M Swing Bucket Rotor Plate Rotor 8x microplate Fixed Angle Rotor Micro Rotor 6x microplate 1x deepwell plate 2x filter 24x15mL 18x2mL Ethanol precipitation can be plate realized at 3 100xg with PT Plate with 89mm or less 21M height can be operated Specifications Model 5220 Maximum Speed e 8 000rpm Maximum RCF e 5 870xg Maximum Capacity e 1 020mL Control system e Micro processor control Brushless motor
7. etails refer to the catalogues relevant to each model Follow instructions given in the relevant Instruction amp Service Manual for operating centrifuges For your safe use of the equipments be sure to read the instruction manual carefully before you start its operation Safety Precautions Parts may be adversely affected by heat humidity and specimens or deteriorated by aging resulting in functional failures or may even lose their safety characteristic to cause accidents The rotor or bucket has been found to be damaged or corroded burnt smell comes out of the equipment You receive a minor electrification when you touch the equipment body by a naked hand Some other abnormality or failure has been found occurring Always discontinue use when phenomena listed gore at right appear To prevent occurrences of functional failures or accidents turn off the power switch pull out the power cable plug from the plug socket and be sure to contact your nearest Kubota Dealer or an office of Kubota Corporation when there is no Kubota Dealer in your neighbourhood KUBOTA CORPORATION http www centrifuge jp 29 9 Hongo 3 chome Bunkyo ku Tokyo 113 0033 Japan Tel 81 3 3815 1331 Fax 81 3 3814 2574 E mail f trade kubotacorp co jp A Note This catalogue is not for distribution in the USA Canada Mexico and Australia as products shown are not for sale in these countries
8. x10mL blood collecting tube 15mL 15 5 17x90 110 4 000 2 670 attached to rotor S17015 4x50mL 34x110 4 000 2 670 attached to rotor S17050 4x50mL 27 35 8x82 110 4 000 2 670 attached to rotor 055 5670 4x50mL conical tube 29 5x117 4 000 2 670 attached to rotor S17049 4x100mL 44 45x110 4 000 2 670 attached to rotor S17100 4x200mL 56 5x104 4 000 2 670 attached to rotor 64x2mL 9 5 11x36 42 3 000 1 570 053 7030 48x10mL 12 14x85 110 3 000 1 600 053 7190 32x10mL blood collecting tube 15mL 15 17 2x85 110 3 500 2 270 053 7130 ST 480M 4x50mL 334 271 38x100 110 5 000 4 640 053 7110 8x50mL 4 270 38x100 110 3 500 2 270 053 7150 16x15mL conical tube 17x121 3 000 1 770 053 7300 4x50mL conical tube x 5 30x117 5 000 4 640 053 5010 8x50mL conical tube 5 30x117 3 500 2 270 053 5020 Plate Rotor PT 20M x COP AIE 9 86 W x128 D x52 H 4 000 1 790 attached to rotor 2x deepwell plate 6 PT 21M SIG pa 86 W x130 D x62 H 5 000 3 100 attached to rotor 2x deepwell plate 6 PT 89M n plats 86 W x130 D x89 H 2 400 1 080 attached to rotor KN 47 Fixed Angle Rotor AT360M 20 10120010 350 220 Micro Rotor 18x2mL 9 50 11x36 42 8 000 5 870 AT 2018M 18x0 5mL 7 00 7 9x25 34 8 000 5 150 055 7590 18x0 4mL 5 4 6 1x26 48 8 000 5 720 055 7580 18x0 2mL PCR 5 9 6 3x20 24 8 000 4 510 055 0500 1 175mL conical tube is made by FALCON