Home
        2 - KUBOTA Centrifuges
         Contents
1.          ISO    CERTIFIED  KUBOTA MFG  CORP        Compact Size of Table Top Centrifuge with  Swing Bucket Rotor  Plate Rotor  amp  Fixed Angle Rotor    This centrifuge can mount Swing Bucket  Rotor  Plate Rotor  amp  Fixed Angle Rotor       68x10mL blood collecting tubes 15mL glass tubes can be  centrifuged       n the case of ST 410M Swing Bucket Rotor  the sealing cap is  available for the bio hazard proof      Plate Rotor can eliminate dye terminator w hen used with the  MultiScreen manufactured supplied by Millipore Corporation     Easy to use and convenient functions      Program memories  3 channels  for repeated routine  operation  A memory function is available for repetitive operations using the  same set values of operation  i e  speed and time  Once the set values  are stored in the memory  simply pressing the    M EMORY    key enables  repetition of the operation once the samples are loaded    e RCF  xg  set operation function  Not only speed but also RCF set function are available  In the case  where the protocol is specified by RCF  the operation conditions are  easily set up      Buzzer and melody at the end of operation  4 different melodies and one buzzer sound allow recognition of the  end of specific operations  in the case where two to five centrifuges  are in operation      Acceleration and deceleration curve can be varied in three  steps according to the type of sample and the experimental  conditions      Compliance with GMP requirements  Equipped with
2.    Copyright O 2006 KUBOTA CORPORATION G1  Printed in Japan    
3.   Speed  RCF  Time  Acceleration  amp  Deceleration  3 channel memories  Alarm display     Lid open  Imbalance  Over speed  Rotor set abnormality   Function for detecting an occurrence of electrical abnormality in motor  inverter  lid interlock and speed sensor   Acceleration   Deceleration e Three level selectors   Rapid  Slow  Super slow  Speed setting     From 300 to 8 000rpm  10rpm increments  Speed indication e Digital display  From O to 8 300rpm  10rpm increments  RCF setting     From 100 to 5 870xg  different by rotor   10xg increments  RCF indication e Digital display  From 0 to 6 320xg  different by rotor   10xg increments  Timer setting and indication     Digital display  with Hold  from 1 min to 99 min  in 1 min increment setting and indication  Power requirements e Single phase AC100V 10   115V 10   50 60Hz  15A  Single phase AC220V 10   230V 10   50 60Hz  10A  Rated voltage and Rated current e 100 115V  6 6A  220 230V  3 4A  Power consumption and Heat output     470W  1 7MJ h  Dimensions  weight     44 W  x 52 D  x 35 H cm    48kg  Test standard e Manufactured and tested in accordance with IEC 61010 2 020      1  Those of projections are not included    All specifications and external appearance subject to change without notice      On Model 5220 only use KUBOTA made rotor  adapter and tube rack  Do not attempt use rotors  adapters or tube racks made by other manufacturers     The rotor mentioned in the catalogue is usable on other KUBOTA centrifuge models  For d
4.  a tachometer port  Actual rotor speed is easy to check        Safety pursued       The various alarm detector sensors secure operation  When  the alarm is detected  the operation stops    e The operation stops when a rotor setup condition sensor  detects that a rotor is not properly set on the drive shaft    e 5220 conforms to the International Safety Standard IEC  61010 2 020     _ Two hooks are provided    on the right and left   sides of the lid to   prevent debris of the   rotor from coming off    should it be broken       during operation                       F4    5    Acceleration deceleration characteristics graph    rpm  Speed    Rapid deceleration  Slow deceleration    Super slow deceleration     Natural deceleration   Super slow acceleration   Slow acceleration  Rapid acceleration  Time      Forthe super slow deceleration  a characteristic change over speed N  can be set from the maximum speed to 0 rpm     Natural deceleration starts at the change over speed N       Acceleration and or deceleration commencement speed  can be selected for the sample easy to stir     Density gradient method is also possible        ST 720M  Swing Bucket Rotor    ST 410M  Swing Bucket Rotor  with sealing cap  S17111     Sealing Cap  Code No S17111     optional     Rotor  Bucket and Tube Rack Table for 5220    Maximum Maximum Bucket Tube Rack    Tube size  mm  Speed RCF Adaptor    Rotor Name Nominal Capacity       diam  x length    rpm    xg     rere SENO     rere CANO       Swinging 
5. Bucket Rotor                                                                                  80x2mL 9 5   11x36   42 3 500 2 290 053 5820 055 4800  96x1 8mL sample cup 17x38 3 500 2 040 053 5820 055 4940  96xRIA tube 10   12x700 95 3 500 2 190 053 5820 055 4730  80x10mL 120 14x700 95 3 500 2 260 053 5820 055 4740  48x10mL blood collecting tube 15mL 150 17 2x750 110 3 500 2 350 053 5820 055 4750  68x7mL blood collecting tube 12 5   13 5x75   110 3 500 2 300 053 5840 055 0260  68x10mL blood collecting tube 15mL 150 17 2x750 110 3 500 2 300 053 5840      ST 720M 28x15mL conical tube 17x121 3 500 2 300 053 5840      32x15mL conical tube 17x121 3 500 2 330 053 5820 055 4780  8x50mL 270 36 4x85   110 3 500 2 330 053 5820 055 4760  16x50mL conical tube 30x117 3 500 2 330 053 5820 055 6070  4x100mL 38   46 5x75   120 3 500 2 330 053 5820 055 4770  4x175mL conical tube  1 61x118 3 500 2 330 053 5820 055 4850  4x200mL conical tube      1 61x130 3 500 2 330 053 5820 055 4850  4x225mL conical tube  1 61x137 3 500 2 330 053 5820 055 4850  4x250mL 60   61 8x100   130 3 500 2 380 053 5820 055 4850  48x2mL 10 7x42 4 000 2 670 attached to rotor   17008  48x5mL 12 5x75 4 000 2 670 attached to rotor 517006  48x7mL 12   12 5x100   112 4 000 2 670 attached to rotor S17007  28x7ML blood collecting tube 12 50 3x75  106 4 000 2 670 attached to rotor S17027  12x15mL conical tube   2 16 5x120 6 4 000 2 670 attached to rotor S17019  ST 410M 12x15mL conical tube  2 16 5x120 6 4 000 2 860  13130      28
6. Code No 352076  and requires a cushion  Code No 352090    200mL conical tube is made by Nalge Nunc  Code No 376813  and requires a cushion adaptor  Code No 377585    225mL conical tube is made by FALCON  Code No 352075  and requires a cushion  Code No 352090      2 Sealing cap cannot be mounted with 817019 tube rack  In the case of 12x15mL conical tube bucket 813130  a sealing cap  Code S17111  can be mounted      3 Bio hazard proof sealing adaptors for 50mL conical tubes  Code No 055 5760  and for 15mL conical tubes  Code No 055 5750  are available          4 15mL glass tubes can be accommodated with an adaptor  Code No 055 7400   The optional cushion  Code No 024 1400  is required      5 15mL conical tubes can be accommodated with an adaptor  Code No 055 1280        6 Before centrifuging  check the strength of the plate  as the bottom plate may be damaged     7 This tray is convenient for taking out the plate                             vable at 121 C         N s Autoclavable at 121  C Autocla  ST 480M PT 20M 21M PT 89M Plate Rotor AT 360M AT 2018M  Swing Bucket Rotor Plate Rotor 8x microplate Fixed Angle Rotor Micro Rotor  6x microplate 1x deepwell plate   2x filter 24x15mL 18x2mL    Ethanol precipitation can be plate    realized at 3 100xg with PT  Plate with 89mm or less  21M  height can be operated        Specifications    Model 5220    Maximum Speed e 8 000rpm  Maximum RCF e 5 870xg  Maximum Capacity e 1 020mL  Control system e Micro processor control  Brushless motor 
7. etails  refer to the catalogues relevant to each model      Follow instructions given in the relevant Instruction  amp  Service Manual for operating centrifuges     For your safe use of the equipments  be sure to read  the instruction manual carefully before you start its  operation     Safety    Precautions       Parts may be adversely affected by heat  humidity and specimens or  deteriorated by aging resulting in functional failures or may even lose their  safety characteristic to cause accidents          The rotor or bucket has been found to be damaged or corroded        burnt smell comes out of the equipment    You receive a minor electrification when you touch the  equipment body by a naked hand      Some other abnormality or failure has been found occurring     Always discontinue  use when    phenomena listed  gore at right appear                 To prevent occurrences of functional failures or accidents   turn off the power switch  pull out the power cable plug from  the plug socket and be sure to contact your nearest Kubota  Dealer  or an office of Kubota Corporation when there is no  Kubota Dealer in your neighbourhood                 KUBOTA CORPORATION   http     www centrifuge jp   29 9 Hongo 3 chome  Bunkyo ku  Tokyo 113 0033  Japan   Tel  81 3 3815 1331 Fax  81 3 3814 2574   E mail  f trade kubotacorp co jp         A       Note  This catalogue is not for distribution in the USA  Canada  Mexico and Australia as  products shown are not for sale in these countries  
8. x10mL blood collecting tube 15mL 15 5   17x90   110 4 000 2 670 attached to rotor S17015  4x50mL 34x110 4 000 2 670 attached to rotor S17050  4x50mL 27   35 8x82   110 4 000 2 670 attached to rotor 055 5670  4x50mL conical tube 29 5x117 4 000 2 670 attached to rotor S17049  4x100mL 44   45x110 4 000 2 670 attached to rotor S17100  4x200mL 56 5x104 4 000 2 670 attached to rotor      64x2mL 9 5   11x36   42 3 000 1 570 053 7030      48x10mL 12   14x85   110 3 000 1 600 053 7190      32x10mL blood collecting tube 15mL 15   17 2x85   110 3 500 2 270 053 7130      ST 480M 4x50mL 334 271 38x100   110 5 000 4 640 053 7110      8x50mL  4 270 38x100   110 3 500 2 270 053 7150      16x15mL conical tube 17x121 3 000 1 770 053 7300      4x50mL conical tube x 5 30x117 5 000 4 640 053 5010      8x50mL conical tube  5 30x117 3 500 2 270 053 5020      Plate Rotor  PT 20M x COP AIE  9 86 W x128 D x52 H  4 000 1 790 attached to rotor    2x deepwell plate  6  PT 21M SIG pa     86 W x130 D x62 H  5 000 3 100 attached to rotor    2x deepwell plate   6  PT 89M n plats   86 W x130 D x89 H  2 400 1 080 attached to rotor KN 47  Fixed Angle Rotor  AT360M              20   10120010   350   220              Micro Rotor  18x2mL 9 50 11x36   42 8 000 5 870          AT 2018M 18x0 5mL 7 00 7 9x25   34 8 000 5 150     055 7590  18x0 4mL 5 4   6 1x26   48 8 000 5 720     055 7580  18x0 2mL PCR 5 9   6 3x20   24 8 000 4 510     055 0500                                   1 175mL conical tube is made by FALCON  
    