Home
ESD Drum Scrubber
Contents
1. AL PROCEDURE The following stain removal procedure is stated here as information only and neither Purafil Inc any of its subsidiaries nor any agent or employee of Purafil Inc make any warranty or other representation regarding the efficacy or safety of this procedure The stain removal could cause further damage to the garment or to the item from which one may attempt to remove the stain If the dust from PURAFIL media comes in contact with organic material there are two possible stain problems 1 Manganese dioxide MnO which is insoluble characterized by a medium brown color and is found in expended PURAFIL media can usually be removed by normal washing 2 New unused Odormix SP media contains sodium permanganate NaMnOa which is a strong oxidant and will react with and discolor any organic material with which it comes in contact These stains which will be brownish black in color may be removed using a solution of sodium bisulfite in water after the garment has been removed from the person CAUTION This procedure should start with a very weak solution gradually increasing the strength until the stain is removed Use of too strong a solution could conceivably cause additional fabric damage NOTE Sodium bisulfite gives off sulfur dioxide SO2 gas therefore it must be used in a well ventilated area PURAFIL Odormix SP media is a 50 50 water wastewater blend of Odorkol media and Odoroxidant SP med
2. aging e For positioning and special handling see Section 3 1 in this manual 1 3 INSPECTION The condition of the unit upon its arrival is critical to its proper operation Prior to start up inspect the unit carefully according to the checklist below Correct any inadequacies before start up to prevent possible damage or inefficiency Note should there be any questions concerning the unit refer to the numbers found on the unit identification plate when contacting the PURAFIL representative PRE OPERATION CHECK LIST YES NO CONDITION 1 Configuration and material are as specified on the sales order form 2 Measurements fit submittal requirements 3 Parts are all present 4 Latches hold securely and gaskets seal properly 5 Labels and serial numbers are present 6 Airflow direction is consistent with installation requirements check labels attached to unit Note Checking specific points is also imperative after the unit is started up See section 3 4 in this manual for checklist 1 4 STORAGE The unit should be protected from the elements during storage especially when storage time is extensive While indoor storage is considered best outdoor storage can be adequate when precautions are taken OUTDOOR STORAGE PRECAUTIONS Cover the equipment with a tarp Intake and discharge openings must be well covered Use of black plastic as a cover may cause excessive condensation and rusting If there is the possibility of moistu
3. ck See Section 3 4 3 1 POSITIONING THE UNIT The standard unit can simply be transported by lift to its pre designed operation location if in close proximity to the skid according to facility safety requirements 3 2 MEDIA BANK FILLING INSTRUCTIONS FOR INITIAL START UP Proper filling installation and maintenance of the chemical filtration media is critical to the unit s efficient operation The drums are designed specifically for media manufactured by Purafil Inc allowing the system to perform at maximum efficiency through proper shape and bed depth Drum filters are pre filled with media at the factory 3 3 MEDIA BANK FILLING INSTRUCTIONS FOR MEDIA REPLACEMENT Once media analysis 300 500 1 000 CFM models only has determined that it is time for a replacement supply of media replace the media according to the instructions below For 100 CFM Model e Media replacement is accomplished by removing the motor blower lid assembly Disconnect power supply e Remove MediaSAKs 5 e Remove Polymedia blue filter e Install Polymedia blue filter e Install new MediaSAKs 5 e Install motor blower lid assembly e See Section 5 0 for disposal precaution For 300 500 1 000 CFM Model e Remove motor blower lid assembly Disconnect power supply e Remove Polymedia blue filter e Remove layer of Odormix SP media e Remove layer of Odorcarb Ultra media e Remove Polymedia blue filter e Clean unit as much as poss
4. d in this bulletin reflects the results of various testing and analytical procedures believed by PURAFIL INC a USA corporation to be useful indicators of the relative performance of air filtration systems and media It is intended for use by persons having appropriate scientific and technical knowledge and experience at their own risk This bulletin does not in any way constitute a representation warranty promise or guarantee by PURAFIL INC of the installed performance of PURAFIL media
5. edients that react with odors and gaseous pollutants to remove them from the airstream Once the active ingredients are spent it is time to replace the media in your system After start up your local PURAFIL representative will work with the owner to periodically secure media samples Purafil Inc will provide regular laboratory analysis of such samples to establish life cycles Note color change of media does not indicate level of remaining life Since every installation varies due to the type and quantity level of the contaminant each operator must develop a sample schedule best suited to their system However until a schedule can be established we recommend that a sample is taken from each vertical media bank and sent for analysis so that a replacement date can be projected with a recommended sampling schedule Media Life Analysis MLA is a complimentary Purafil Inc service MLA Sample Kits are available through Purafil Inc If analysis reveals that it is time to replace the media order the appropriate pounds of media required per module used in the unit See Media Sampling Service Guide for instructions on how to take a media sample from your unit 5 0 SPECIAL PRECAUTIONS Disposal PURAFIL media is a non toxic non flammable substance Filtration of contaminants through PURAFIL media causes molecular changes to occur and the resulting product is usually not harmful to the environment Although special precautions are general
6. he drum then proceeds through the poly media pre filter MEDIA BED 100 CFM model consists of 3 ft cubic feet of Odorcarb Ultra and 2 ft cubic feet of Odormix SP Each cubic foot of media is contained in a MediaSAK for easy handling and disposal 300 CFM model comes complete with 7 ft cubic feet of Odorcarb M Ultra media 280 lbs and 3 ft of Odormix SP media 120 bei 500 CFM model comes complete with 13 ft cubic feet of Odorcarb Ultra media 520 Ibs and 4 ft cubic feet of Odormix SP media 160 Ibs 1 000 CFM model comes complete with 31 ft cubic feet of Odorcarb Ultra media 1240 lbs and 8 ft cubic feet of Odormix SP media 320 Ibs BLOWER the air is then propelled further by the blower assembly which includes a mill and chemical duty motor and direct drive blower assuring even quiet airflow FINAL FILTER DS 300 DS 500 and DS 1000 any remaining contaminants such as media dust and airborne contaminants are removed in this final stage by a polymedia filter FIGURE 1 BASIC DESIGN e SE 1 PURAFIL First inclean air 3 0 INSTALLATION After the entire pre operative inspection is finished Section 1 3 complete the following sequence for installation 1 Remove the unit from the skid and position it in the designated operation location 2 Plug in the electrical connections 3 Start the unit 4 Perform post start inspection che
7. ia 7 0 WARRANTY PURAFIL warrants hardware equipment manufactured by PURAFIL to be free from defects in material and workmanship under normal use and service for twelve 12 months from startup date or eighteen 18 months from shipment date PURAFIL S obligation under this warranty shall be limited to replacing any parts thereof which shall be demonstrated to have been defective THIS WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS PURAFIL MAKES NO WARRANTIES AS TO MERCHANTABILITY OR AS TO THE FITNESS OF THE MERCHANDISE FOR ANY PARTICULAR USE AND SHALL NOT BE LIABLE FOR ANY LOSS OR DAMAGE DIRECTLY OR INDIRECTLY ARISING FROM THE USE OF SUCH MERCHANDISE OR FOR CONSEQUENTIAL DAMAGES No person firm or corporation is authorized to assume for PURAFIL any other liability in connection with the sale of these goods Equipment parts and material manufactured by others and incorporated in PURAFIL equipment are warranted by PURAFIL ONLY TO THE EXTENT OF THE ORIGINAL MANUFACTURERS LIABILITY TO PURAFIL 8 0 TROUBLESHOOTING SYMPTOM PROBLEM CHECKS REMEDY Media Bank Airflow too low Filters loaded Replace filters 9 0 SAMPLE RECORD Sampling Record Schedule Represented By Important Notice The information containe
8. ible by washing packing material with water and let dry e Install new Polymedia blue filter e Install new Odorcarb Ultra media e Install new Odormix SP media e Install new Polvmedia blue filter e Install motor blower lid assembly e Connect power supply e See Section 4 3 for disposal precaution 3 4 POST START INSPECTION CHECK Before initial start up of system contact your local PURAFIL representative Their name and phone number is attached to your system Operate all DS models at the lowest airflow required to maintain a negative pressure and maximize media life YES NO CONDITION 1 Joints seals and gaskets do not leak 2 Particulate filters have been installed 4 0 MAINTENANCE 4 1 REPLACEMENT PARTS AND MATERIALS While Purafil Inc products are built for durability some parts of the PURAFIL unit will require replacement during the normal lifetime of the equipment Replacement items may be ordered from your local PURAFIL representative or from Purafil Inc Consumables In order to maintain proper performance levels particulate filters and PURAFIL media must be replaced periodically as they have a finite life See Media Sampling Procedure Service Guide Moving Parts Bearings motors etc are all subject to gradual deterioration and or sudden breakdown 4 2 MEDIA REPLACEMENT Need for Sampling PURAFIL engineered dry chemical media has a finite life Our media contains special active ingr
9. ly not required when disposing of spent media government regulations may require specific disposal procedures if the resulting product could be harmful to the environment Large quantities of PURAFIL media should not be disposed of in dumpster like equipment because the weight of the media could cause difficulties in handling the dumpster Independent laboratory analysis for Environmental Protection Agency toxicity characteristics may be required if the contaminants eliminated from your environment include heavy metals and pesticides Inhalation A well ventilated work area is suggested for changing the PURAFIL media as dusting occurs in fresh media due to handling abrasion Workers should avoid direct inhalation of considerable PURAFIL dust as it induces sneezing In closed unventilated spaces dust masks such as the 3 M No 8500 are suggested Water Avoid exposing the PURAFIL media to water or precipitation as this dissolves permanganate content Storage of media should be in a dry place with less than 95 relative humidity Exposure of permanganate solution to the skin causes brown staining which is temporary and not harmful This staining can be removed by washing in a diluted solution of water and sodium bisulfite Eye Contact If dust is exposed to the eyes or delicate membrane flush thoroughly with water and seek treatment by a physician Follow normal procedures for exposure to abrasive dust 6 0 PURAFIL STAIN REMOV
10. re collection allow for proper drainage Do not place heavy equipment on top of the unit Store Purafil media in a dry place with less than 95 relative humidity 1 5 FOUNDATION AND CLEARANCES FOUNDATIONS Some units may require new or reinforced foundations due to their weight Always be sure to check that the existing foundation is adequate for the unit to be installed Units to be used indoors require particular attention to strength of foundation In some instances a concrete base is best suited to the system Concrete lessens the chance for vibration than if metal structures are used CLEARANCE All units should be easily accessible for the required periodic maintenance Do not block return and discharge grilles Sufficient minimum clearances can be recommended by the local PURAFIL representative 2 0 BASIC DESIGN OF THE DRUM FILTER Designed to clean odorous air the drum filter coupled with the final particulate filter contains an inlet pipe blower a media bed housed in a LDPE drum and diffuser Pre engineered in a single unit the drum filter is designed to exhaust recycled air The drum filter is supplied with Purafil media The drum filter has a quiet low horsepower motor and low pressure drop The drum filter includes the following components 1 INLET PIPING DIFFUSER Air enters through a 4 100 CFM model 8 300 500 CFM models or 10 1 000 CFM models Fernco fitting prior to entering t
11. s to be sure that the rigging equipment can handle them safely Be sure that the unit is balanced well in the transporting device Always conduct a thorough check when the installation is complete Never enter an enclosed blower cabinet or reach into a housing while fan is running The motors in PURAFIL equipment get very hot This is normal and should not be regarded as a problem with the motor However take special care to avoid touching the hot areas 1 2 RECEIVING INSTRUCTIONS Systems are normally shipped assembled and with motors mounted All units are attached securely to skids It is recommended that units be left on their skids for protection and ease of handling while transporting Straps rigging slings or hooks attached to the skids may be used with proper care The units are well protected with triple wall board and are secured with metal bands Forklifts may be used under the skids but exercise caution to prevent damage Upon receiving systems from Purafil Inc note any shipping damage obvious or hidden to your carrier and on your Bill of Lading All problems should be handled between the customer and carrier except for U P S shipments which require the customer to contact Purafil Inc for action e lf the unit is to be stored before use see Section 1 4 in this manual e If the unit is to be installed immediately be sure to check Section 3 0 in this manual e To uncrate unit cut metal bands and remove pack
12. www purafil com SERVICE WW DRUM SCRUBBER INSTALLATION OPERATION amp MAINTENANCE INSTRUCTIONS Purafil Inc e 2654 Weaver Way Doraville Georgia 30340 U S A e www purafil com e tel 770 662 8545 800 222 6367 QUALITY AGEMENT SYSTEM CERTIFIED BY DNV Purafil 2012 SrvcGde WW DS 01 ISO 9001 2008 TABLE OF CONTENTS 1 0 PRE INSTALLATION INSTRUCTIONS 1 1 SAFETY CONSIDERATIONS 1 2 RECEIVING INSTRUCTIONS 1 3 INSPECTION 1 4 STORAGE 1 5 FOUNDATIONS AND CLEARANCES 2 0 BASIC DESIGN OF THE DRUM FILTER 3 0 INSTALLATION 3 1 POSITIONING THE UNIT 3 2 MEDIA BANK FILLING INSTRUCTIONS INITIAL START UP 3 3 MEDIA BANK FILLING INSTRUCTIONS MEDIA REPLACEMENT 3 4 POST START INSPECTION CHECK 4 0 MAINTENANCE 4 1 REPLACEMENT PARTS AND MATERIALS 4 2 MEDIA REPLACEMENT 5 0 SPECIAL PRECAUTIONS 6 0 PURAFIL STAIN REMOVAL 7 0 WARRANTY 8 0 TROUBLESHOOTING 9 0 SAMPLE RECORD LIST OF FIGURES FIGURE TITLE 1 BASIC DESIGN 1 0 PRE INSTALLATION INSTRUCTIONS 1 1 SAFETY CONSIDERATIONS Read this Service Manual carefully Be thoroughly familiar with the controls and the proper use of the equipment This manual should be retained with the unit because it contains the information necessary for proper maintenance Keep all nuts bolts and screws tight to be sure the equipment is in safe working condition CAUTION Installer should be a trained experienced service person Check the assembly and component weight
Download Pdf Manuals
Related Search
Related Contents
UNIVERGE UM8000 User Guide.book Sanyo DS27930, DS32424 CRT Television User Manual SmartMaxx Gold Manual do Usuário Users manual Bedienungsanleitung Bulletin municipal juin 2012 en émergence - Enseignementsup-recherche KOBOLD VR100 Offre d`essai 30 jours 平成15年門審第115号 漁船第五十二大慶丸機関損傷事件 言渡年月日 "取扱説明書" Copyright © All rights reserved.