1. Calibration PRODUCT ANNOUNCEMENT USD 5502A and 5502E Multiproduct Calibrators New Fluke Calibration 5502A 5502E Multi Product Calibrators provide robust transportable solution for calibrating in the lab or the field What is NEW Improved functional performance throughout the instrument The 5502A 5502Ecombine the best of its predecessors the 5500A 5500E accuracy and 9100 20 A current calibrators plus adds improvements found in the superior 5522A wider ranges of resistance and capacitance protection and transportability The result is the best in class performance for a MPC aimed at the Tier 3 calibrator user workload of the 3 5 4 5 dmm class of instrument The 5502A 5502E are the best Multiproduct Calibrators compared to any other calibrator on the market for this class of workload Output terminal electrical overload protection The 5502A 5502E provide reverse power protection up to a minimum of 300 volts with immediate output disconnection when overloads are applied Plus it is protected from over current damage by fuses on the current output terminals There is robust overload safety for all functions Improved Ergonomic Design The 5502A 5502E have new look and feel pioneered with the 5522A The 5502A 5502e have larger ergonomic handles for easier access to connection terminals and are more comfortable to use when carrying the instrument Easily Transportable and Read
2. 16 What comes standard in a 5502A The 5502A calibrator comes standard with all its various electrical calibration functions Scope calibration capability is optional Included is a full report of calibration with data An accredited report of calibration is optional What options can be installed in the 5502A The two scope calibration options 300 MHz and 600 MHz are the only options for this calibrator These are available at time or purchase or installed by a service center at a future date as an upgrade Is there a trade in program for 5500As or 9100s for a 5502A No trade in program is in place at this time Is MET CAL compatible with the 5502A Yes MET CAL Release Version 8 1 is able to fully control the 5502A Due out in Q3 2012 How will existing MET CAL users get this version of MET CAL Upgrades are available through the Gold support program or as a purchased upgrade Will existing MET CAL 5500 or 9100 procedures work with the 5502A No because the calibrator s output terminal configuration is different and the resulting operator safety issues a different FSC must be used to operate the 5502A with MET CAL rather than use the existing 5500A or 9100 FSCs Will the 5502A FSC use the old 5500A style syntax or the newer 5522A style syntax The 5502A will use the new Name Value Instrument syntax NVI giving the user better flexibility in use editing and future calibrator upgrade compatibility e The 5500A used t
3. No the 5502E is not retrofit able with any of the scope calibration options Will the user operator manual be available together with 5502A at the same time Yes a full user s manual will be available with the 5502A in English language supplied on a CD DVD with the instrument The getting started manual will translated in several languages printed and supplied with the instrument Fluke Calibration Confidential Page 7 Product Announcement 5502A 5502E 17 Is the calibration procedure to calibrate the 5502A will be the same as 5500A The performance verification procedure for the 5502A is similar but not identical to the 5500A procedure There are some range and specification differences between the two instruments 18 Is a service manual available for the 5502A The specific test points required in a verification procedure of a 5502A are included in the user s manual A detailed service manual will be available at approximately one year after introduction Fluke Calibration Confidential Page 8 Product Announcement 5502A 5502E
4. Current non Sine Waves Triangle Truncated Sine Square Not on 5502EModel available Target Market Third party calibration labs andin house calibration labs need a calibratorwhich can support for a wide range of electrical T amp M workload The 5502A can also be used for production testing for manufacturers of Test and Measurement instruments or other items needed a multifunction precision source There are thousands of existing owners of older 5500A and 9100 calibrators who are candidates to have them replaced with a new improved model the 5502A Points of differentiation with 5500A Max 20 5 A of dc and ac current Max 11 A of de and ac current 1100 M ohms max variable resistance 330 M ohms max variable resistance 220 pF to 110 mF variable capacitance 330 pF to 1 1 mF variable capacitance Input Terminal Protection to 300V Improved Chassis Design Ergonomic Handles with 9100 Basic dcv accuracy of 50 ppm year Basic dcv accuracy of 60 ppm year 1100 M ohms max variable resistance 400 M ohms max variable resistance ACV to 500 MHz ACV to 100 MHz 220 pF to 110 mF variable capacitance 500 pF to 40 mF variable capacitance Fluke Calibration Confidential Page 5 Product Announcement 5502A 5502E 01 Hz to 2 MHz Frequency 0 5 Hz to 10 MHz Frequency Not required no benefit to the user Lead connection mat No such function availa
5. age of 4 volts dc 3V rms ac compliance and long on time with an on time of at least 20 minutes in a typical lab condition Other competing calibrators limit max current to 30 seconds of operation or less with compliance current at 1 10 of this capability Fully Variable Resistance from 0 The 5502A 5502E provide an accurate calibrated resistance at the exact value the to 1100 M Ohms UUT needs Competing calibrators offer only limited number of fixed resistors and optional variable resistance with a poor spec and only over a limited range of values Fully variable capacitance from The 550WA provides an accurate calibrated capacitance at the exact value the UUT 220 pF to 110 mF needs Competing calibrators offer only a few fixed capacitance values and optional variable capacitance with a poor spec and only over a very limited range of values Protection circuitry Protects the calibrator from being damaged due to an unfamiliar UUT or out of lab conditions or operator error Cost of ownership is reduced due to robustness and increased uptime Power calibration Conveniently calibrates digital watt meters and power quality instruments Compatible with Fluke 5500 Coil For users who need to calibrate instruments that measure up to 1000 Amps and 9100 200 Dual Coil Versatile software solutions Customers can select from several software solutions based on their needs and budget Not on 5502EModel available 5502A 5502E Summary S
6. and 4 5 digits digital multimeters e 50 ppm dc V accuracy e 20A of dc and ac current for calibrating current clamps and current meters e Wider ranges of resistance to 1100 M ohms and capacitance to 110 mF e Oscilloscope calibration to 300 or 600 MHz models 5502A 3 and 5502A 6 e Reverse power protection check before connect immediate output disconnection and fuse protection on the output terminals for mistake proof protection against common user errors e Paired with the 52120A the 5502A 5502E can supply up to 120A directly and usable with 25 amp 50 turn coils e Easy transportation with an optional rugged carrying case featuring built in handles and wheels and removable front rear access doors for in situ calibration in almost any environment In summary the 5502A 5502E source direct voltage and current alternating voltage and current with multiple waveforms and harmonics two simultaneous voltage outputs or voltage and current to simulate dc and ac power with phase control resistance capacitance thermocouples and resistance temperature detectors The 5502A 5502E can be fully automated with MET CAL Plus Calibration Management Software to improve throughput consistency and productivity MET CAL Plus helps meet the requirements for documented processes procedures and reports mandated by most quality standards Fluke Calibration Confidential Page 2 Product Announcement 5502A 5502E Introduction Schedule The 5502A cali
7. ble recommend a 5320A or optional with 5080A 9100 135 Insulation Continuity Tester Calibration Module Obsolete and not available use MET CAL or computer automation PCMCIA Storage Modules with Transmille 3041 All functions of the 5502A have full operating ranges without compromises can drive full loads or perform over wide conditions The Transmille specs have good or adequate performance over a very limited set of conditions cannot operate over a range of loads or testing times Refer to the detailed comparison material of Fluke for more information 20A current with strong compliance and long operating time Specs to 30A but usable only to 20A poor compliance short operating time Fully variable resistance to 1100 M ohm Fixed resistors with adequate specs optional poor and limited variable resistance Fully variable capacitance to 110 mF Limited set of 7 fixed capacitors and optional poor variable capacitance over just a few ranges The scope option has a full set of testing functions that can be fully adjusted over the necessary needs of an oscilloscope The scope option has few scope calibration functions with severe limitations on its key functions with poor accuracy which makes scope calibration impractical With Transmille 3050 All functions of the 5502A have full operating ranges without compromises can drive full loads or perform over wide conditions Th
8. brator will be open to accept orders on September 1 2012 Embargo Date Initial delivery time 8 weeks ARO Standard delivery targeted to be 4 6 weeks Ordering and pricing information 4190103 5502E 120 Multi Product Calibrator 15400 4190248 5502E 240 Multi Product Calibrator 15400 4184101 5502A 120 Multi Product Calibrator 20295 4184112 5502A 240 Multi Product Calibrator 20295 4188629 5502A 3 120 Multi Product calibration 300 MHz scope option 29120 4188760 5502A 3 240 Multi Product calibration 300 MHz scope option 29120 4189037 5502A 6 120 Multi Product calibration 600 MHz scope option 37070 4189134 5502A 6 240 Multi Product calibration 600 MHz scope option 37070 Bundle discount For the 5502E 5502A also the recently introduced bundle discount as per previous 5500A E models applies A discount of 30 on the total price of the software and hardware when purchasing MET CAL BASE software database with 1 license Accessories already previously available with the 5500A Demonstration Kit The demo kit includes the 5502A calibrator Fluke 1587 dmm and insulation tester and transit case 55XX CASE for free The regular 10 additional demo discount applies A 1587 dmmi insulation tester is used to show that the 5522A can sense and turn off when high voltages are applied to it terminals without any problem The 1587 can supply voltages at varying levels from 50 volts to over 1000 volts Yet b
9. e Transmille specs are inferior versus the 5502A with adequate performance over a very limited set of conditions cannot operate over a range of loads or testing time Refer to the detailed comparison material of Fluke for more information 20A current with strong compliance and long operating time 22A max current with weak specs poor compliance short operating time Fully variable resistance to 1100 M ohm Just a 8 fixed resistors over a small range of decades values and no variable resistance Fully variable capacitance from 220 pf to 110 mF Limited set of 5 fixed capacitors and no variable capacitance Fully capable thermocouple and RTD temperature calibration functions No temperature calibration option The scope option has a full set of testing functions that can be fully adjusted over the necessary needs of an oscilloscope The scope option has few scope calibration functions with severe limitations on its key functions with poor accuracy which makes scope calibration impractical Sales Material and Tools Check the European Launch Page 5502A 5502E Multi Product Calibrators Service Requirements amp Plans The 5502A is serviced and calibrated in all major Fluke service centers that are able to service 5500 series and 9100 series calibrators Fluke Calibration Confidential Page 6 Product Announcement 5502A 5502E Frequently Asked Questions 1 12 13 14 15
10. ecause of its current limiting design it is very safe to use ina demonstration environment Fluke Calibration Confidential Page 3 Product Announcement 5502A 5502E Demo Kit Ordering Information Demo Kit 5502A 6 with 1587 DMM and 4189560 5502A DEMO 120 Sey Case 37385 Demo Kit 5502A 6 with 1587 DMM and 4189666 5502A DEMO 240 55xx Case 37385 Phase in Phase out Requirements The 5502A MPC replaces the older Fluke models 5500A and 9100 calibrators These will be phased out sometime following the 5502A introduction The 9100 will initially be phased out first due to part limitation issues followed later by the 5500A Features and Benefits pees ee Calibration performance over 11 Addresses a wide range of workload with accurate complete and fully capable different standard functions functions wide ranges with professional capabilities that cover the needs of this workload Workloads include up to 4 5 digit DMMs as well as temperature instruments data loggers strip chart recorders and other core T amp M instruments Optional Scope Calibration to Optional scope calibration with full functions includingleveled sine wave covering 600 MHz bandwidths to a max of either 300 MHz or 600 MHz fast edge for rise time time marker wave generator varying amplitude settings pulse various trigger testing and input impedance measurement 20A dc and ac with high A max current of 20 5A that can drive a compliance volt
11. he old FSC syntax style MET CAL implemented the 5502A with the new structure of FSC similar to the 5522A FSC As a result any 5500A procedures will need to be converted to the new FSC syntax This can be done by the MET CAL user or by a translator process More information on the translation process will soon to be furnished by the MET CAL team e Similarly any existing 9100 procedures will need to be translated to the new 5502A MET CAL FSC syntax Does the 5502A usesame the commands of other Fluke 55XX calibrators Yes the 5502A uses the same remote control commands as the earlier 5500A 5520A and 5522A series calibrators The only difference is that it answers the remote ID command with a response of being a 5502A Does the 5502A emulate the commands of Fluke Wavetek 9100 calibrators No the 5502A does not emulate the Fluke Wavetek 9100 calibrator remote control commands What is the future availability of the 5500A calibrator The 5500A will be phased out approximately 6 months after the 5502A introduction What is the future availability of the 9100 calibrator The 9100 will go on limited availability with a last time buy period soon Is the 5500A upgradable to 5502A No a 5500A is not upgradeable to a 5502A Is the 5502A upgradable to 5522A No a 5502A is not upgradeable to a 5522A Is the 5502E upgradable to 5502A No a 5502E is not upgradeable to a 5502A Is the 5502E retrofit able with one of the 5502A scope calibration options
12. pecifications Technical Specifications Voltage DC Range 0 to 1020V Best 1 Year Specification 0 005 of setting Current DC Range 0 to 20 5A Best 1 Year Specification 0 01 of setting Resistance Range 0 to 1100 MQ continuously variable Fluke Calibration Confidential Page 4 Product Announcement 5502A 5502E Voltage AC Current AC Capacitance Thermocouple Simulation amp Thermocouple Measure RTD Simulation DC Power AC Power Phase Frequency Additional Functions Best 1 Year Specification 0 009 of setting Range 1 mV to 1020V 10 Hz to 500 kHz Sine Best 1 Year Specification 0 03 of setting Range 29 mA to 20 5A 45 Hz to 30 kHz Sine Best 1 Year Specification 0 04 of setting Range 220 pF to 110 mF continuously variable Best 1 Year Specification 0 25 of setting 11 Thermocouple typesplus voltage at either 10uV or 1 mV per degree Celsius Best 1 Year Specification 0 14 C 8 RTD types Best 1 Year Specification 0 03 C Range 10 9 mW to 20 9 kW Best 1 Year Specification 0 33 of watts Range 10 9 mW to 20 9 kW 10 Hz 30 kHz PF variable 0 to 1 lead or lag Best 1 Year Specification 0 08 of watts Range 0 to 179 99 10 Hz to 30 kHz Best 1 Year Specification 0 15 of setting Range 0 01 Hz to 2 MHz Best 1 Year Specification 2 5 ppm of setting Harmonics 2 to 50 AC Voltage non Sine Waves Triangle Truncated Sine Square AC Voltage with DC Offset AC
13. y to Work The 5502A 5502E are compatible with the 5522A scarrying case with wheels and built in handle making the move process very easy The new carrying case has detachable front and rear covers so it is immediately ready to work without being removed from the case Fluke Calibration Confidential Page 1 Product Announcement 5502A 5502E Comparison 5502A vs 5502E The 5502E is identical to the 5502A except the following functions are not applicable e The DC and AC Power Simultaneous Voltage and Current options functions e The Dual Voltage Simultaneous Voltage Voltage output function e The Phase function e The Harmonics function e The rear panel 10 MHz Reference IN and OUT connectors are not functional The terminals are for service only e The 300 MHz and 600 MHz options are not compatible with the 5502E The 5502E is targeted at those customers who have a limited workload of handheld test tool instruments Such customers include various calibration labs small in house calibration and repair workshops or meter manufacturers needing production and test calibration capabilities 5502A 5502E MPC at a glance Fluke Calibration introduces the 5502A 5502e Multi Product Calibrators full functioned calibrators that cover a wide range of common workload The 5502A 55502E have the best full range of functions and accuracy in its class The Fluke Calibration 5502A 5502E feature e 11 full functions including calibrating 3 5