1. EXCLUSIONS The following are considered external environmental factors beyond the control of C 1 and which may cause damage and or need for service which will be specifically excluded from this warranty i e not a material defect in components and workmanship occurring in the course of manufacture 1 Damage by extraneous causes such as fire water lightning chemical or galvanic attack etc 2 Physical damage due to force dropping misuse or other abuse 8 Use other than that as described in this Instruction Manual misapplication 4 Repair by someone other than Chlorinators Incorporated 5 Improperly installed The exclusions listed above are provided for purposes of clarification and are not intended to in any way limit or eliminate other possible exclusions NO OTHER WARRANTIES Unless otherwise explicitly agreed in writing and signed by a C l officer it is understood that this is the only written warranty given by C l for the systems and components stated The dealers or representatives of C l may not make verbal representations that add modify or change the written warranties contained herein or change the extent and nature of C l s liability In no event shall C I be liable for direct consequential special incidental or punitive damages of any kind with respect to the product including but not limited to those which may allegedly arise out of breach of warranty breach of contract negligence
2. Stuart Florida 34994 USA Phone 772 288 4854 Fax 772 287 3238 www regalchlorinators com Email regal regalchlorinators com REGAL GAS CHLORINATORS PURE WATER PURE AND SIMPLE Copyright 2012 Chlorinators Incorporated Printed in U S A Pub No 1112 1
3. strict liability or any other law governmental regulation or court decision except as provided herein GENERAL SPECIFICATIONS The REGAL Model SC401 Dual Cylinder Scale has been Accuracy 1 FS specifically designed for the water and waste water industry Resolution 1 Ib for the weighing of 150 Ib chlorine gas cylinders Scale Readability 1 2 Ib Scale Capacity 300 Ibs The REGAL Model SC401 Dual Cylinder Scale can Safe Overload Capacity 400 Ibs accommodate any gas cylinder not exceeding 12 diameter and 150 lbs net weight FEATURES 1 Simultaneously weighs two cylinders independently and displays the net weight on separate indicators 2 Adjustable cross bar and chains adapt to different size cylinders 3 All scales are assembled tested and calibrated at the factory Simple assembly on the job site is all that is required Easy to read 5 scale length with 150 graduations that allow for 1 2 Ib readability A DRAWING NO 1 REGAL MODEL SC401 Dimensions PARTS LIST Item Quantity PartNo Description 1 2 SC601 Zero Knob 2 1 SC602 Overlay 3 1 SC603 Backplate 4 1 SC604 Support Arm Strap 5 1 SC605 Support Arm 6 2 SC606 5 16 18 x 4 Hex Bolt 7 2 SC607 5 16 Hex Nut 8 2 SC608 5 16 Lock Washer 9 2 SC609 Cylinder Chain 10 1 SC610 Post 11 1 SC611 Post Clamp 12 12 SC612 10B x 5 8 Self Tap 13 6 SC613 Pivot Screw 14 2 SC614 Disc 15 1 SC615 Deck 16 2 SC616 Stop E Ring 17 2 SC617 St
4. Instruction Bulletin 401 SOSIL MODEL SC401 DUAL CYLINDER SCALE INSTALLATION SERVICE MANUAL DUAL CYLINDER SCALE El chlorinotors incorporated AA SE Blew Eur Need erent CU MEN EA The entire contents of this manual MUST be read and understood prior to installing and operating this equipment Do not discard this manual upon completion of the installation as this manual contains information essential to the safe handling operation and maintenance of this equipment jchlorinators incorporated 1044 SE Dixie Cutoff Road Stuart FL 34994 USA Tel 772 288 4854 Fax 772 287 3238 www regalchlorinators com Email regal regalchlorinators com CHLORINATORS INCORPORATED ONE 1 YEAR LIMITED WARRANTY Chlorinators Incorporated hereinafter called C 1 sets forth the following warranties with respect to its REGAL Model SC401 Dual Cylinder Scale This warranty does not apply to the purchase of spare parts or other services performed by C I or its authorized Dealers This represents the entire agreement between C I and Buyer also referred to as end user and shall apply unless modified in writing and signed by a C I Officer and this warranty and its intended terms shall supersede any prior negotiations correspondence understandings or agreements written or oral The Buyer agrees to and accepts all terms of this warranty by its contracting for or acceptance of C I s products and forms
5. XTENSION RODS and stand the scale upright It is IMPORTANT to note that the scale MUST be installed on a FLAT LEVEL surface floor Anchor bolt the deck to the floor while being careful NOT to over tighten the bolts Doing so will distort the deck causing inaccuracy and possible damage 9 Finally mount the support arm to the Post and attach the cylinder safety chains antes DRAWING NO 3 REGAL MODEL SC401 Assembly Instructions Scale Indicator FACE UP SC401 Post and Column Assembly j g 2 w Q Scale Base 8 Extension Rod x a on E Ring 3 Brass Bottom Stop Steelyard ve mi mimi ee a mA 4 Slide Together OPERATION 1 Place a full chlorine cylinder in the center of the circular disc on each side of the platform and connect the safety chains to hold the cylinder in place Mount the REGAL Gas Feed Regulator to the cylinder and make the required connections Use the tare weight adjusting knobs to set each scale pointer to the net weight 150 Ibs for Chlorine of each cylinder The scale is now ready to monitor the weight of chemical remaining as it is being drawn from each cylinder DRAWING NO 4 REGAL MODEL SC401 Steelyard Clevis Assembly DRAWING NO 5 REGAL MODEL SC401 Spider Assembly DRAWING NO 6 REGAL MODEL SC401 Pointer Assembly F jchlorinators incorporated 1044 SE Dixie Cutoff Road
6. eelyard Stop 18 2 SC618 Steelyard 19 2 SC619 Adjusting Nut 20 2 SC620 Jam Nut 21 2 SC621 Clevis 22 2 SC622 Clevis Bushing 23 2 SC623 Link 24 2 SC624 Tension Spring 25 2 SC625 Zero Adjustment Link 26 2 SC626 Socket Set Screw 27 1 SC627 Post Cap 28 2 SC628 Link E Ring 29 2 SC629 Dial Scale 30 2 SC630 Pointer Crank Axle 31 2 SC631 Pointer E Ring 32 2 SC632 Pointer 33 2 SC633 Axle Bushing 34 2 SC634 Pointer Axle 35 2 SC635 Lock Nut 36 6 SC636 Disc Washer 37 6 SC637 Perimeter Flexure 38 6 SC638 Perimeter Clamp 39 2 SC639 Center Clamp 40 2 SC640 Center Flexure 41 4 SC641 Short Lever 42 2 SC642 Long Lever DRAWING NO 2 43 4 SC643 6A 3 8 Self Tap Hex 44 8 SC644 10 24 x 3 8 Hex Head 45 12 SC645 10B 5 8 Self Tap Phillips 46 8 SC646 10A 3 8 Self Tap Hex 47 3 SC647 10 32 x 3 1 4 Bolt 48 2 SC648 5 16 18 x 2 1 2 Long Hex Head Bolt 49 2 SC649 5 16 Lock Washer 4 ASSEMBLY amp INSTALLATION 1 Upon receipt of the scale immediately unpack and remove all scale parts and inspect for shipping damage Refer to Drawing No 3 below Place the POST ASSEMBLY on a flat surface floor with the INDICATOR face up Screw the threaded CHECKING CALIBRATION The scales are fully calibrated before they are packaged and shipped from the factory However once installed the following test should be performed to ensure proper operation 1 Remove all weight from the platforms EXTENSION RODS into the BRASS BOTTOM STOPS 2 Usi
7. ng one foot press separately on the circular disc located on each side of the platform while observing CAUTION DO NOT STAND THE POST VERTICAL AS the pointer s to make sure they move smoothly without DAMAGE TO THE STEELYARD CAN RESULT interference 3 Remove the plastic tie wraps from the SCALE DECK 3 If any restriction of movement occurs remove the front base and stand the SCALE DECK on its back skirt cover and correct the interference Then replace the cover 4 Slide the SCALE DECK and the POST ASSEMBLY 4 Separately turn each of the two Tare Knobs located on together while using the EXTENSION RODS to top of the post counter clockwise until there is no guide the BRASS BOTTOM STOPS through the tension remaining on the steelyard springs The knob s DECK and levers located under the DECK will turn freely at this time 5 Screw the two 5 16 x 2 1 2 long bolts with lock washers 5 Now turn each Tare Knob clockwise and the pointer through bottom of DECK and into bottom of POST will start to drop Continue turning the knob slowly assembly Tighten securely until the pointer drops just below zero approx 1 8 inch 6 Pull the EXTENSION RODS through the lever holes on the dial scale ei A ek into the snap groove of the 6 After completing these steps for both sides the scale i is ready for OPERATION 7 Release the EXTENSION RODS and allow the BRASS BOTTOM STOPS to rest back into the lever holes under the DECK assembly 8 Unscrew the E
8. o registered by Chlorinators Incorporated as to date of shipment model number accessories options and billing name If the serial number is missing defaced changed or in any way rendered unreadable Chlorinators Incorporated shall at its option have the right to declare the warranty void If the serial number does not match the registered model number as to but not limited to such items as accessories or options the same shall apply The warranty shall apply against material defects in components and workmanship occurring in the course of manufacture Buyer s sole remedy for breach of said warranty shall be at C 1 s option either repair or replacement of any unit which is received by C I at its plant in Stuart Florida shipping charges prepaid by buyer within the time period set forth above and which is found by C I to be defective by reason of manufacture Notwithstanding the foregoing C I shall not be liable to Buyer for damages including personal injury or death to any person or persons or claims of any kind by a third party or property damage or loss of business or profits In no event shall C I be liable to Buyer for consequential or accidental damages of any kind even if C I was aware of the possibility of such damages There are no remedies except those set forth Further that there are no other authorized warranty repair facilities other than those at the Chlorinators Incorporated factory in Stuart Florida
9. or other documents or statements issued by Buyer or any other person shall not modify or otherwise affect any of the following terms Buyer should be aware that reseller must rely entirely upon Chlorinators Incorporated s warranties or assume their own responsibility The following states C I s entire warranty and represents Buyer s exclusive remedy with respect to its product Such warranties are expressly given in lieu of any other warranty expressed or implied including but not limited to those of merchantability and fitness for a particular purpose This expressed warranty or any other warranty implied by law shall not cover defects due to accident improper use or non compliance with C I s operating and maintenance assembly installation manual and instructions Recommendations and advice as to specifications capabilities design installation engineering application and use of products are provided as an accommodation and are intended only as suggestions C I assumes no liability for such recommendations and advice and they are not to be construed as constituting any warranty expressed or implied TERMS OF WARRANTY C I warrants its REGAL Model SC401 Dual Cylinder Scale for a period of one 1 year from date of shipment from C I Date of shipment from the factory shall be determined solely on the basis of the serial code affixed to the SC401 s enclosure The serial number contains a date code All serial numbers are als