Home
System Board D2119 for RX300 S3
Contents
1. 3 6 LEDs L1 L2 L3 L7 L8 L15 f L16 CPU 1 i Lote B3 Y F il iRMC L17 L22 124 DR CPU 2 wm g 4 m an L258 L273 L18 126 128 a SAS O i mm EE Figure 4 LEDs L1 and L2 are visible from outside on the rear of the server All the other LEDs are only visible if the cover of the server is open D2119 RX300 S3 Technical Manual 23 LEDs Features The LEDs have the following meaning LED Indicator Meaning L1 Status Global Error orange indicates a prefailure orange flashing indicates a failure Reasons for a failure may be overheating of one of the sensors sensor defect fan defect CPU error Software detected an error memory banks L2 ID blue server is identified via ServerView L3 board orange aux voltage available L4 board green system running L5 board red configuration error The system board will be held in reset Possible configuration errors are e g old CPU populated CPUs with different FSB requirements populated CPU1 not populated L6 board green flashing iRMC server management controller is ok off RMC not alive L7 board orange RAID cache dirty L8 L15 orange flashing indicates an error in the corrensponding memory module
2. A B Cc D Slot 1 PCI IRQ line 1 PCI IRQ line 2 PCI IRQ line 3 PCI IRQ line 4 Slot 2 PCI IRQ line 3 PCI IRQ line 4 PCI IRQ line 1 PCI IRQ line 2 Slot 3 PCI IRQ line 2 PCI IRQ line 3 PCI IRQ line 4 PCI IRQ line 1 Slot 4 PCI IRQ line 1 PCI IRQ line 2 PCI IRQ line 3 PCI IRQ line 4 Slot 5 PCI IRQ line 1 PCI IRQ line 2 PCI IRQ line 3 PCI IRQ line 4 VGA PCI IRQ line 6 SAS PCI IRQ line 1 LAN PCI IRQ line 1 PCI IRQ line 2 USB PCI IRQ line 8 PCI IRQ line 7 PCI IRQ line 6 PCI IRQ line 5 RAID PCI IRQ line 3 A D Interrupt output of the PCI controller 3 4 Screen resolution Depending on the operating system used the screen resolutions in the following table refer to the screen controller on the system board If you are using an external screen controller you will find details of supported screen resolutions in the operating manual or technical manual supplied with the controller Screen resolution Supported colours 640x480 8 bit 16 bit 24 bit 800x600 16 bit 24 bit 1024x768 16 bit 1152x864 8 bit 1280x1024 8 bit D2119 RX300 S3 Technical Manual 21 Temperature system monitoring Features 3 5 Temperature system monitoring Temperature and system monitoring aim to reliably protect the computer hardware against damage caused by overheating In addition any unnecessary noise is also prevented by reduc
3. 3 3 PCI bus Slot 5 PCI Express Riser riser ext 5 Slot 4 PCI Express hot plug 4 Slot 3 PCI Express hot plug 3 Slot 2 PCI X Slot 1 PCI X Figure 3 PCI slots PCI slots The following table shows an overview of the PCI slots PCI slot 64bit Frequency Description 32bit in MHz 1 64 bit 133 64 bit PCI X slot 2 64 bit 133 64 bit PCI X slot 3 PCI Express x8 slot hot plug capable 4 PCI Express x8 slot hot plug capable 5 PCI Express x8 slot prepared for riser card Hot plug PCI PCI slots 3 and 4 are hot plug capable Optional riser card PCI slots 5 is prepared for an extension by a riser card with 3 x 64 bit slots 18 Technical Manual D2119 RX300 S3 Features PCI bus 3 3 1 ISA bus resources Device IRQ Address DMA Timer 0 040 043 Keyboard 1 060 064 Serial port COM2 3 3F8 3FF 2F8 2FF 3E8 3EF 2E8 2EF Serial port COM1 4 3F8 3FF 2FB 2FF 3E8 3EF 2E8 2EF free 5 Floppy disk drive controller 6 3F0 3F5 3F7 2 Parallel interface LPT1 7 278 27B 378 37B 0 1 3 3BC 3BF Real time clock RTC 8 070 071 free 9 10 11 Mouse controller 12 Numeric processor 13 OFO OFE IDE controller primary 14 1F0 1F7 3F6 IRQ interrupt assigned as shipped Address this address can be used for your particular device Address this DMA can be used
4. If two keys need to be pressed at the same time then this is shown by placing a hyphen between the two key symbols quotation marks indicates names and terms that are being empha sized indicates an operation that to be performed gt CAUTION indicates warnings which if ignored will endanger your health destroy the system or lead to the loss of data Li indicates additional information notes and tips Table 1 Notational conventions D2119 RX300 S3 Technical Manual 2 Important notes In this chapter you will find essential information regarding safety when working with your server CAUTION With the system board installed you must open the system to access the system board How to access the system board of your system is described in the appropriate service supplement When handling the system board refer to the specific notes on safety in the operating manual and or service supplement for the respective server 2 1 Notes on safety CAUTION e The actions described in these instructions should only be performed by authorized qualified personnel Equipment repairs should only be performed by qualified staff Any failure to observe the guidelines in this manual and any unauthorized openings and improper repairs could expose the user to risks electric shock fire hazards and could also damage the equipment Please note that any unauthorized openings o
5. L8 memory bank 4 module DIMM 2D L9 memory bank 2 module DIMM 1D L10 memory bank 4 module DIMM 2C L11 memory bank 2 module DIMM 1C L12 memory bank 3 module DIMM 2B L13 memory bank 1 module DIMM 1B L14 memory bank 3 module DIMM 2A L15 memory bank 1 module DIMM 1A L16 CPU orange flashing error in CPU1 24 Technical Manual D2119 RX300 S3 Features LEDs LED Indicator Meaning L17 CPU orange flashing error in CPU2 L18 SAS green flashing SAS controller active L21 L28 green fan is running fans orange indicates a prefailure orange indicates a failure flashing L21 CPU fan 1 L22 CPU fan 2 L23 CPU fan 4 L24 CPU fan 5 L25 CPU fan 3 L26 system fan 1 L27 CPU fan 6 L28 system fan 2 D2119 RX300 3 Technical Manual 25 Interfaces and connectors Features 3 7 Interfaces and connectors 1 3 4 24 f Daun i l 23 HE em i M s 6 iRMC Eu ni J a ey can CPU 2 mo my les 22 3 9 A Battery H i 11 21
6. HY Properties estore Defaults Esc Exit Menu F1 Shift l Help Enter Select Item Change Item L CHS Mapping SCSI Plug and Play Mapping it is recommended don t change this setting or Alternate CHS Mapping Menu Advanced Device Properties see page 38 Menu Spinup Properties see page 39 Menu PHY Properties see page 40 D2119 RX300 S3 Technical Manual 37 SAS IME configuration program SAS and RAID Menu Advanced Device Properties It is recommended don t change this setting Fis Logic MPT Setup Utility Advanced Device Properties SAS1068 Maximum INT 13 devices for this adapter 24 IO Timeout for Block Devices 0 IO Timeout for Block Devices Removable 0 IO Timeout for Sequential Devices 0 IO Timeout for Other Devices 0 LUNs to Scan for Block Devices A11 LUNs to Scan for Block Devices Removable A11 LUNs to Scan for Sequential Devices A11 LUNs to Scan for Other Devices A11 Removable Media support None Restore Defaults Esc Exit Menu F1 Shift 1 Help Enter Select Item Change Item L J 38 Technical Manual D2119 RX300 S3 SAS and RAID SAS IME configuration program Menu Spinup Properties It is recommended don t change this setting fist Logic MPT Setup Utility Spinup Properties SAS1068 Direct Attached Spinup Delay Secs C 2 Direct Attached Max Targets to Spinup C 01 Expander Spinup Delay Secs C 01 Expander Ma
7. SAS Mo o MIS 20 1918171615 14 13 12 Figure 5 Schematic view of the system board D2119 1 Parallel port optional 13 RAID key 2 Slots for main memory modules 14 RAID DIMM 3 Stromversorgung 12V PC98 15 KVM power 4 Main power 16 IPMB 5 Front panel 17 DIP switch see page 29 6 SATA1 18 HDLED 7 IDE primary 19 NMI 8 Floppy disk drive 20 Reset 9 USB7 21 PCI slots 10 SATA3 22 Hot plug signaling 11 SAS1 6 USB3 4 SMB2 23 External ports 12 CPU and system fans 24 Serial port COM2 optional 26 Technical Manual D2119 RX300 S3 Features Interfaces and connectors 3 7 1 External ports 20000 0 0 0 0 0 4 3 Figure 6 External ports of the system board D2119 1 PS 2 mouse connector 6 serial interface COM1 2 USB ports 1 and 2 7 PS 2 keyboard connector 3 LAN2 connector 8 ID LED 4 LAN1 connector 9 Global Error LED 5 VGA port The serial interface COM1 can be used as default interface or to communicate with the iRMC LAN connectors On this system board you will find a dual channel Broadcom LAN controller BCM5715 The LAN controller supports the transfer rates of 10 Mbit s 100 Mbit s and 1 Gbit s The LAN controller supports WOL function through Magic Packet It is also possible to boot a device without its own boot hard di
8. 3 3 1 ISA DUS TESOUIGEE un aan ek ie E Gol wR ek de 3 3 2 PCI GSOUCES soa bc aoa kes rei OSE ES 3 4 Screen resolution cin Ka a aaa 3 5 Temperature system monitoring 3 6 LEDS js BS pos o A Gee 3 7 Interfaces and connectors o e 3 7 1 EXENTOS 2 a4 ad a A A AA ES 3 8 Settings wiih SWICHES a gt a RE dobie 4 SAS and RAID za us as as a ee a 4 1 SAS IME configuration program oaoa 4 2 RAID on Motherboard ROMB 5 Replacing the lithium battery Abbreviat ns lt asno ss PR asas D2119 RX300 S3 Technical Manual 1 Introduction This technical manual describes the system board D2119 which can be equipped with one or two Intel processors Further information about drivers is provided in the readme files on the hard disk on the supplied ServerSupport or ServerStart CDs You will find further information in the BIOS description Notational conventions The meanings of the symbols and fonts used in this manual are as follows italics indicates commands menu items file and path names or software programs fixed font indicate system output on the monitor semi bold fixed indicates values to be entered through the keyboard font Key symbol indicates keys according to their representation on the keyboard If capital letters are to be entered explicitly then the Shift key is shown e g SHIFT A for A
9. Hardware Design Guide SMB System Management Bus SMM Server Management Mode 50 Technical Manual D2119 RX300 S3 Abbreviations SMP Symmetrically Multi Processing UHCI Unified Host Controller Interface USB Universal Serial Bus VGA Video Graphics Adapter VRD Voltage Regulator Down VRM Voltage Regulator Module WfM Wired for Management WOL Wake up On LAN D2119 RX300 S3 Technical Manual 51 A A A A nn EE eee e Fujitsu Siemens Computers GmbH User Documentation 81730 M nchen Germany Fax 49 700 372 00000 email manuals Q fujitsu siemens com http manuals fujitsu siemens com Comments Suggestions Corrections Submitted by Comments on System Board D2119 for RX300 S3 D2119 RX300 S3 A A A A nn EE eee e Fujitsu Siemens Computers GmbH User Documentation 81730 M nchen Germany Fax 49 700 372 00000 email manuals Q fujitsu siemens com http manuals fujitsu siemens com Comments Suggestions Corrections Submitted by Comments on System Board D2119 for RX300 S3 D2119 RX300 S3 O FUJITSU Information on this document On April 1 2009 Fujitsu became the sole owner of Fujitsu Siemens Compu ters This new subsidiary of Fujitsu has been renamed Fujitsu Technology So lutions This document from the document archive refers to a product version which was released a considerable time ago or which is no longer marketed Please
10. Shift l Help Alt M Global Properties Alter Boot Order Ins Del Alter Boot List L J Terminating the SAS IME configuration program Depending on the current menu level you can display the previous menu by pressing the ESC key If you have made changes in the current menu you will be prompted to store them gt To quit the configuration program press the ESC key until a corresponding message is displayed Configuring IME gt To configure IME select your adapter in the menu by using the arrow keys Press the ENTER key to change into the menu Adapter Properties gt From there select the depending entry and press the ENTER key to change into the submenus Detailed instruction on the configuration of IME are contained in the IME User s Guide 32 Technical Manual D2119 RX300 S3 SAS and RAID SAS IME configuration program Menu Adapter Properties f LSI Logic MPT Setup Utility Adapter Properties SAS1068 Adapter Properties SAS1068 PCI Slot 00 PCI Address Bus dev Func 02 08 00 MPT Firmware Revision 1 10 01 00 IR SAS Address 5003005F FFFFFFFO Status Enabled Boot Order 0 Boot Support Enabled BIOS amp OS J RAID Properties SAS Topology Advanced Adapter Properties Esc Exit Menu F1 Shift 1 Help Enter Select Item Change Item L J Boot Support Enabled BIOS amp OS it is recommended don t change this setting or Enabled BIO
11. for your particular device Default settings are shown in bold print D2119 RX300 S3 Technical Manual 19 PCI bus Features 3 3 2 PCI resources PCI IRQ Line x Assignment of the PCI interrupts PCI IRQ Line x defines which ISA interrupts are used for the separate PCI slots If you select Auto in the BIOS setup the interrupts are assigned automatically and no further settings are required Multifunctional PCI boards or boards with an integrated PCI to PCI bridge can use several PCI interrupts INTA INTB INTC INTD Monofunctional PCI boards default only use one PCI interrupt INTA per PCI slot The PCI interrupts INTA INTB INTC and INTD are available for each PCI slot The same interrupt can be assigned simultaneously to several PCI boards You should avoid this condition due to reduced performance If you use a setting other than Auto the Plug amp Play functionality of the system BIOS for the corresponding PCI boards is deactivated Auto The PCI interrupts are assigned automatically in accordance with the Plug amp Play guidelines Disabled No ISA interrupt is assigned to the PCI interrupt 3 4 5 6 7 9 10 11 12 14 15 The selected ISA interrupt is assigned to the PCI interrupt You may not select an ISA interrupt that is used by a component on the system board e g controller or an ISA board 20 Technical Manual D2119 RX300 S3 Features Screen resolution
12. 2 optional 1 parallel port optional 2 PS 2 interfaces for keyboard and mouse 2 USB 2 0 ports with 480 Mbits s rear side 1 VGA port 2 RJ45 LAN ports Technical Manual D2119 RX300 S3 Features Overview PCI slots 2xPCI X 3x PCI Express 1 x riser extension BIOS features Phoenix System BIOS V 4 06 Rompilot SMBIOS 2 31 DMI MultiProcessor Specification 1 4 Server Hardware Design Guide 3 0 WfM 2 0 IPMI 1 5 ACPI 2 0 support USB keyboard mouse LSI SAS RAID BIOS boot possible from 120 MB floppy disk drive CD ROM DVD Festplatte LAN console redirection support OEM logo CPU memory disable hotspare memory support Environmental protection battery in holder Form factor 290 x 480 mm D2119 RX300 S3 Technical Manual 15 Main memory Features 3 2 Main memory The system board supports up to 32 Gbyte main memory 8 slots 4 memory banks with 2 modules are available for the main memory Each memory bank can be populated with two 512 Mbyte 1 Gbyte 2 Gbyte or 4 Gbyte FBD533 PC2 4200F or FBD667 PC2 5300 fully buffered DIMM memory modules A memory bank can be configured as hot spare bank optional As in the basic configuration memory bank 1 is populated with 1 Gbyte 2 Gbyte 4 Gbyte or 8 Gbyte memory modules the memory extensions can be performed up to three times for memory bank 2 3 and 4 ECC with mem
13. 2002 96 EC concerning used electrical and electronic appliances waste electrical and electronic equipment WEEE The guideline determines the framework for the return and recycling of used appliances as applicable throughout the EU To return your used device please use the return and collection systems available to you You will find further information on this at www fujitsu siemens com recycling For details on returning and reuse of devices and consumables within Europe refer to the Returning used devices manual or contact your Fujitsu Siemens Computers branch office subsidiary or our recycling centre in Paderborn Fujitsu Siemens Computers Recycling Center D 33106 Paderborn Tel 49 5251 8 18010 Fax 49 5251 8 18015 12 Technical Manual D2119 RX300 S3 3 Features 3 1 Overview Processors 1or2x Intel Xeon dual core processors 2 processor sockets LGA771 for Intel Xeon processor 2x2 or 4 MB second level cache on die unified 64 byte cache line size 24 KB L1 cache on die data 16 KB L1 cache on die instruction 2xVRM 11 0 onboard EVRD Main memory 8slots for main memory FBD533 PC2 4200F or FBD667 PC2 5300 Fully Buffered DIMM memory modules with 512 MB 1 Gbyte 2 Gbyte and 4 Gbyte maximum 32 Gbyte of memory minimum 1 Gbyte 2 memory modules maximum 32 Gbyte s bandwidth supports 4 way interleaved memory subsystems 4 identical memory modul
14. AID Hot Drive Pred Size Num Disk Spr Status Fail MB 4 SEAGATE ST373454SS 1501 Yes No Primary No 34332 5 SEAGATE ST3146854SS 1501 Yes No Secondary No 34332 t Menu F1 Shift l Help Only two RAIDs can be configured on the SAS Controller 1068 The administration of the RAID system can be set later by a tool in your operating system see therefore the documentation Global Array Manager D2119 RX300 S3 Technical Manual 35 SAS IME configuration program SAS and RAID Menu SAS Topology SAS Topology displays the allocations of the hard disks f LSI Logic MPT Setup Utility SAS Topology SAS1068 Device Identifier Device SAS1068 02 08 00 Info I_ Enclosure Direct Attach Devices Controller _ Bay 0 SEAGATE ST3146854SS 1501 SAS _ Bay 1 SEAGATE ST336754SS 1501 SAS _ Bay 2 SEAGATE ST336754SS 1501 SAS _ Bay 4 RAID Physical Disk SAS _ Bay 5 RAID Physical Disk SAS I_ IM VOL LSTLOGICLogical Volume 3000 SEAGATE ST373454SS 1501 gt SEAGATE ST3146854SS 1501 Esc Exit Fl Help Alt D Device Properties Alt M More Keys k J 36 Technical Manual D2119 RX300 S3 SAS and RAID SAS IME configuration program Menu Advanced Adapter Properties f LSI Logic MPT Setup Utility Advanced Adapter Properties SAS1068 IRQ OB NUM Yes IO Port Address 3000 Chip Revision ID 01 CHS Mapping SCSI Plug and Play Mappingl Advanced Device Properties Spinup Properties P R
15. S only Menu RAID Properties see page 34 Menu SAS Topology see page 36 Menu Advanced Adapter Properties see page 37 D2119 RX300 S3 Technical Manual 33 SAS IME configuration program SAS and RAID Menu RAID Properties In this menu you can start the RAID configuration menu fist Logic MPT Setup Utility Select New Array Type SAS1068 View Existing Array View Create IM Volume Crea Create IME Volume Crea ALL Create IS Volume Crea 2 to ALL Array of 3 to 8d optional hot spare the existing te Integrated disks plus an optional hot spare Data on the primary di te Integrated DATA on array te Integrated 8 disks DATA on array configuration Mirror Array of 2 sk may be migrated Mirrored Enhanced isks including an disks will be DELETED array of disks will be DELETED Esc Exit Menu F1 Shift l k Help Enter Choose array type to create Esc Return to Adapter Properties 34 Technical Manual D2119 RX300 S3 SAS and RAID SAS IME configuration program Menu View Existing Array View Array displays the status of the configured hard disks fist Logic MPT Setup Utility View Array SAS1068 Array tof 1 Identifier LSILOGICLogical Volume 3000 Type IM Scan Order 4 Size MB 34332 Status Optimal Manage Array Esc Ex i Enter Select Item Alt N Next Array C Create an array Slot Device Identifier R
16. a risk of explosion The batteries may only be replaced with identical batteries or with a type recommended by the manufacturer It is essential to observe the instructions in chapter Replacing the lithium battery Technical Manual D2119 RX300 S3 Important notes Notes on safety Modules with electrostatic sensitive components Systems and components that might be damaged by electrostatic discharge ESD are marked with the following label A Ate When you handle components fitted with ESDs you must observe the following points under all circumstances Figure 1 ESD label e You must always discharge yourself of static charges e g by touching a grounded object before working e The equipment and tools you use must be free of static charges e Remove the power plug from the power socket before inserting or removing boards containing ESDs e Always hold boards with ESDs by their edges e Never touch pins or conductors on boards fitted with ESDs e Use a grounding cable designed for this purpose to connect yourself to the system unit as you install deinstall the board e Place all components on a static safe base You will find a detailed description for handling ESD components in the relevant European or international standards EN 61340 5 1 ANSI ESD S20 20 D2119 RX300 S3 Technical Manual 9 CE Certificate Important notes Notes about boards During installation deinstallati
17. ch the product can be dismantled and the extent to which it can be recycled This saves resources and thus reduces the harm done to the environment Notes on saving energy Devices that do not have to be on permanently should not be switched on until they need to be used and should be switched off during long breaks and on completion of work Notes on packaging Please do not throw away the packaging We recommend that you do not throw away the original packaging in case you need it later for transporting Notes on dealing with consumables Please dispose batteries in accordance with local government regulations Do not throw batteries and accumulators into the household waste They must be disposed of in accordance with local regulations concerning special waste All batteries containing pollutants are marked with a symbol a crossed out rubbish bin on wheels In addition the marking is provided with the chemical symbol of the heavy metal decisive for the classification as a pollutant Cd Cadmium Hg Mercury Pb Lead Notes on labeling plastic housing parts Please avoid attaching your own labels to plastic housing parts wherever possible since this makes it difficult to recycle them D2119 RX300 S3 Technical Manual 11 Environmental Protection Important notes Returning recycling and disposal The device may not be disposed of with household rubbish This appliance is labelled in accordance with European Directive
18. een finished WebBIOS will be started The controller selection is the start page shown in figure 9 The further actions will be executed on the selected controller You validate the controller with Start Start calls the main menu shown in figure 10 The main menu allows to get all information and settings which are offered by WebBIOS wdapter Selection Mi Adapter No Bus No Device No Type Pirmuare Version Figure 9 WebBIOS start page controller selection 42 Technical Manual D2119 RX300 S3 SAS and RAID RAID on Motherboard ROMB Nega RAID BASC figuration Utility Virtual ration al Bd i e Physical Drives Virtual Drives eg VDD RRID 34454 NE Optimal Figure 10 WebBIOS main menu WebBIOS can be operated by mouse or keyboard For operating by keyboard you can use the keys shown in the table above A detailed description of the WebBIOS is contained in the MegaRAID SAS Software User s Guide to select a menu item EE to modify an item ENTER to validate a selection AA to scroll right or left between a line D2119 RX300 S3 Technical Manual 43 5 Replacing the lithium battery In order to save the system information permanently a lithium battery is installed to provide the CMOS memory with a current When the charge is too low or the battery is empty a corresponding error message is provided The lithium batte
19. es have to installed at the same time ECC multiple bit error detection and single bit error correction memory scrubbing function Single Device Data Correction SDDC function Chipkill Hot spare memory support Chips on the system board Intel Blackford Chipset Dual channel Broadcom LAN controller BCM5715 LSI 8 channel SAS controller LSI SAS1068 Flash for SAS BIOS and NVRAM for integrated mirroring Flash and NVRAM for RAID Integrated VGA controller with PCI 32 Bit 33 MHz Super I O controller SMSC DME1737 Flash EPROM for SCSI BIOS BIOS LAN D2119 RX300 S3 Technical Manual 13 Overview Features server management with RMC FSC System thermal and system management controller ADT7462 server management SM Internal connectors floppy disk connector fine print 26 pin 1 IDE primary 2 Serial ATA combined connector for 6 x SAS SAS signaling 2 x USB for USB ports on front side 1 x SMB 1 USB connector for USB streamer optional SCSI activity connector HD LED main power connector 12V 12V 5V 3 3V and 5V auxiliary combined connector for 12V power supply and PC98 front panel 8 direct connectors for fans IPMB connector KVM power connector NMI header reset header hot plug signaling connector 1 RAID key 1 DDRII connector RAID DIMM External connectors 1 serial port COM1 second serial port COM
20. f the device will result in the invalidation of the warranty and exclusion from all liability e Transport the device only in the antistatic original packaging or in packaging that protects it from knocks and jolts e Only install expansions that are allowed for the system board If you install other expansions you may damage the requirements and rules governing safety and electromagnetic compatibility or your system Information on which system expansions are suitable can be obtained from the customer service centre or your sales outlet e The warranty expires if the device is damaged during the installation or replacement of system expansions D2119 RX300 S3 Technical Manual 7 Notes on safety Important notes N Batteries Components can become very hot during operation Ensure you do not touch components when making extensions to the system board There is a danger of burns Transmisson lines to peripheral devices must be adequately shielded To the LAN wiring the requirements apply in accordance with the standards EN 50173 and EN 50174 1 2 As minimum requirement the use of a protected LAN line of category 5 for 10 100 MBps Ethernet and or of category 5e for Gigabit Ethernet is considered The requirements of the specification ISO IEC 11801 are to be considered Never connect or disconnect data transmission lines during a storm lightning hazard CAUTION Incorrect replacement of lithium battery may lead to
21. ing the fan speed and information is provided about the system status The following functions are supported Temperature monitoring Measurement of the processor and the system internal temperature by an onboard temperature sensor measurement of the ambient temperature by a 12C temperature sensor Fan monitoring The CPU power supply unit and system fans are monitored Fans that are no longer available blocked or sticky fans are detected Fan control The fans are regulated according to temperature Sensor monitoring The removal of or a fault in a temperature sensor is detected Should this happen all fans monitored by this sensor run at maximum speed to achieve the greatest possible protection of the hardware Voltage monitoring When voltage exceeds warning level high or falls below warning level low an alert will be generated System Event Log SEL All monitored events of the system board are signalised via the Global Error LED and recorded in the System Event Log They could be retrieved in the BIOS Setup or via ServerView 22 Technical Manual D2119 RX300 S3 Features LEDs PRIMERGY Diagnostic LEDs Optical signaling through the LEDs on the systemboard identifies defective modules and components as well as gaining information on the PDA
22. is queried at system startup if the password protection is enabled in BIOS Setup in Security menu the Password field must be set to Enabled on The password query is skipped Passwords are deleted off The password query is effective default setting D2119 RX300 S3 Technical Manual 29 Settings with switches Features Write protection for Flash BIOS switch 3 Switch 3 is used to define whether the System BIOS is write protected or not on The System BIOS can neither be written to nor deleted Flash BIOS update from floppy disk is not possible off The System BIOS can be written or deleted Flash BIOS update from floppy disk is possible default setting Write protection for floppy disks switch 4 Switch 4 is used to define whether floppy disks can be written or deleted in the floppy disk drive To write and delete floppy disks the write protection in BIOS Setup must be disabled in menu Security the field Diskette Write must be set to Enabled on The floppy disk drive is write protected off Floppy disks can be read written and deleted default setting 30 Technical Manual D2119 RX300 S3 4 SAS and RAID 4 1 SAS IME configuration program The system board is equipped with an eight channel SAS controller 1068 from LSI Logic You will find the exact location of the SAS connector in the schematic view of the system board The BIOS of the onboard SAS controller includes a menu driven SAS IME In
23. line Package DMI Desktop Management Interface DRAM Dynamic Random Access Memory ECC Error Correction Code EEPROM Electrical Erasable Programmable Read Only Memory EPROM Erasable Programmable Read Only Memory EMRL Embedded RAID Logic EVRD Enterprise VRD HPC Hotplug Controller ICE In Circuit Emulation IDE Integrated intelligent Drive Electronics IME Integrated Mirror Enhanced IOOP Intelligent Organisation Of PCI IPMB Intelligent Platform Management Bus 48 Technical Manual D2119 RX300 S3 Abbreviations IPMI Intelligent Platform Management Interface iRMC integrated Remote Management Controller LAN Local Area Network LED Light Emitting Diode MPS Multi Processor Specification NMI Non Maskable Interrupt OEM Original Equipment Manufacturer OHCI Open Host Controller Interfache OS Operating System PCI Peripheral Components Interconnect PDA Prefailure Detection and Analyzing PIO Programmed Input Output PLD Programmable Logic Device PS U Power Supply Unit D2119 RX300 S3 Technical Manual 49 Abbreviations PWM Puls Wide Modulation PXE Preboot eXecution Environment RAID Redundant Array if Inexpensive Disks RSB Remote Service Board RST ReSeT RTC Real Time Clock SAS Serial Attached SCSI SATA Serial ATA SCSI Small Computer Systems Interfache SDDC Single Device Data Correction SDRAM Synchronous Dynamic Random Access Memory SHDG Server
24. note that all company references and copyrights in this document have been legally transferred to Fujitsu Technology Solutions Contact and support addresses will now be offered by Fujitsu Technology So lutions and have the format Ots fujitsu com The Internet pages of Fujitsu Technology Solutions are available at http ts fujitsu com and the user documentation at hrrp manuals ts fujitsu com Copyright Fujitsu Technology Solutions 2009 Hinweise zum vorliegenden Dokument Zum 1 April 2009 ist Fujitsu Siemens Computers in den alleinigen Besitz von Fujitsu bergegangen Diese neue Tochtergesellschaft von Fujitsu tr gt seit dem den Namen Fujitsu Technology Solutions Das vorliegende Dokument aus dem Dokumentenarchiv bezieht sich auf eine bereits vor l ngerer Zeit freigegebene oder nicht mehr im Vertrieb befindliche Produktversion Bitte beachten Sie dass alle Firmenbez ge und Copyrights im vorliegenden Dokument rechtlich auf Fujitsu Technology Solutions bergegangen sind Kontakt und Supportadressen werden nun von Fujitsu Technology Solutions angeboten und haben die Form ts fujitsu com Die Internetseiten von Fujitsu Technology Solutions finden Sie unter http de ts fujitsu com und unter http manuals ts fujitsu com finden Sie die Benutzerdokumentation Copyright Fujitsu Technology Solutions 2009
25. on of the system board observe the specific instructions described in the service manual for the server Remove the plug from the mains outlet so that system and system board are totally disconnected from the mains voltage To prevent damage to the system board the components and conductors on it please take great care when you insert or remove boards Take great care to ensure that extension boards are slotted in straight without damaging components or conductors on the system board or any other components for example EMI spring contacts Be careful with the locking mechanisms catches centring pins etc when you replace the system board or components on it for example memory modules or processors Never use sharp objects screwdrivers for leverage 2 2 CE Certificate The shipped version of this board complies with the requirements C of the EEC directive 89 336 EEC Electromagnetic compatibility Compliance was tested in a typical PRIMERGY configuration 10 Technical Manual D2119 RX300 S3 Important notes Environmental Protection 2 3 Environmental Protection Environmentally friendly product design and development This product has been designed in accordance with standards for environmen tally friendly product design and development This means that the designers have taken into account important criteria such as durability selection of materials and coding emissions packaging the ease with whi
26. ory scrubbing and with the Single Device Data Correction SDDC function is supported Module population EOS DIMM 2D SL m E DIMMAD 3 ahi DIMM 2C E e ur DIMM 1C 2 _ Oc DIMM 2B gt my e e DIMM 1B I mo Be DIMM 2A Fa rn UI 2 DO DIMM 1A 2 En Figure 2 Main memory The memory modules have to be based on FBD533 PC2 4200F or FBD667 PC2 5300 fully buffered DIMM modules and must be populated in pairs Each pair must consist of identical memory modules 2 way interleaved mode 16 Technical Manual D2119 RX300 S3 Features Main memory The module capacity between pairs can differ pair 1A 1B can be populated with two 512 Mbyte modules and pair 2A 2B with two 1 Gbyte modules Following table shows the mandatory population order module pair module pair module pair module pair 1A 1B 1C 1D 2A 2B 2C 2D populated empty empty empty populated populated empty empty populated populated populated empty populated populated populated populated Memory Mirroring Memory Mirroring needs 4 or 4 4 identical memory modules Memory 1 1 2 2 bank Channel A B Cc D A Cc D module Population 4 identical memory modules 4 identical memory modules 4 identical memory modules D2119 RX300 S3 Technical Manual 17 PCI bus Features
27. ridge and the LSI SAS chip 1068 In the system boards basic configuration this RAID solution is not available If you want to use this solution you need the following additional components iButton contains a key for clearing cache module either an TBBU2 cache module with battery or a DDR2 400 MHz memory module You must switch off the system before installing the new components The Button in installed in the socket named RAID KEY The cache module is inserted in the socket named RAID DIMM You will find the exact location of the SAS connectors in the schematic view of the system board Through activating of this RAID implementation the onboard SAS chip is integrated into the RAID configuration The configurations described in the chapter SAS IME configuration program are then no longer available SAS connectors The RAID implementation give the possibility to connect devices via the SAS chips of six SAS channels channel 0 to channel 5 This channels are assigned to the SAS connector You will find the exact location of the SAS connector in the schematic view of the system board D2119 RX300 S3 Technical Manual 41 RAID on Motherboard ROMB SAS and RAID SAS RAID configuration program WebBIOS WebBIOS allows to modify or control the controller settings and the RAID config uration WebBIOS is called by the key combination CONTROL h during the controllers POST When the boot process has b
28. ry must then be replaced The lithium battery must be replaced with an identical battery or a battery type recommended by the manufacturer CR2450 Do not throw lithium batteries into the trashcan It must be disposed of in accordance with local regulations concerning special waste Make sure that you insert the battery the right way round The plus pole must be on the top at Figure 11 Replacing the lithium battery Press the locking spring into direction of of the arrow 1 so that the lithium battery jumps out of its socket Remove the battery 2 gt Insert a new lithium battery of the same type into the socket 3 and 4 D2119 RX300 S3 Technical Manual 45 Abbreviations The technical terms and abbreviations given below represent only a selection of the full list of common technical terms and abbreviations Not all technical terms and abbreviations listed here are valid for the described system board ACPI Advanced Configuration and Power management Interface ASSR Automatic Server Recovery and Restart ATA Advanced Technology Attachment BBU Battery Backup Unit BIOS Basic Input Output System BMC Baseboard Management Controller CMOS Complementary Metal Oxide Semiconductor COM COMmunication port CPU Central Processing Unit DDR Double Data Rate DIMM Dual In line Memory Module D2119 RX300 S3 Technical Manual 47 Abbreviations DIP Dual In
29. sk via LAN Here Intel PXE is supported The LAN1 port serves as management interface and is prepared for RemoteView The LAN connectors are equipped each with two LEDs light emitting diode indicating the transfer rate and the activity D2119 RX300 S3 Technical Manual 27 Interfaces and connectors Features Figure 7 LAN connector 1 LAN transfer rate green off transfer rate 10 Mbit s or no yellow connection green on transfer rate 100 Mbit s yellow jon transfer rate 1000 Mbit s 2 LAN link aktivity green on LAN connection off no LAN connection flashing LAN transfer 28 Technical Manual D2119 RX300 S3 Features Settings with switches 3 8 Settings with switches ON Eee 12 3 4 Figure 8 DIP switch i Preset for switches 1 to 4 Off Recovering System BIOS switch 1 Switch 1 enables recovery of the old system BIOS after an attempt to update has failed To restore the old system BIOS you need a Flash BIOS Diskette please call our customer service centre on The system boots from the Flash BIOS floppy disk from Drive A and reprograms the system BIOS on the board off The System BIOS is started with the system BIOS from the system board default setting Skipping the password query switch 2 Switch 2 is used to define whether the password
30. system Board D2119 for RX300 3 Technical Manual Edition May 2006 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual Your feedback helps us optimize our documentation to suit your individual needs Fax forms for sending us your comments are included in the back of the manual There you will also find the addresses of the relevant User Documentation Department Certified documentation according to DIN EN ISO 9001 2000 To ensure a consistently high quality standard and user friendliness this documentation was created to meet the regulations of a quality management system which complies with the requirements of the standard DIN EN ISO 9001 2000 cognitas Gesellschaft f r Technik Dokumentation mbH www cognitas de Copyright and Trademarks Copyright 2006 Fujitsu Siemens Computers GmbH All rights reserved Delivery subject to availability right of technical modifications reserved All hardware and software names used are trademarks of their respective manufacturers Contents 1 Introduction 24H RR RB RR ie 2 Important notes lt lt 5er Gap Hr 2 1 Notes on Saey s o ah ara ken hie 22 CE CON cah e r RS e a 23 Environmental Protection aooaa a e 3 Feal res lt Sade near rn dr a 3 1 CHEMICON 246644 22 28S bb EARS RE EDS RE 3 2 Mist ONIN s soa dd ha eS a ew bk ee he 3 3 PORN 2 2 44 6 64 tava es 6 amp bk edie a rn
31. tegrated Mirror Enhanced configuration program This program allows you to change almost all of the option settings of the SAS controller When you boot the system a SAS BIOS message listing the SAS devices connected is displayed If a SAS BIOS error message appears or problems arise with SAS devices please read the documentation of your SAS device If you are unable to trace or rectify the error please contact your dealer or our customer service centre Working with the keyboard Use the following keys when running the program arrow keys to make selections E E to change a selection ENTER to accept a selection ESC to call the previous menu and to terminate the SAS configu ration program F2 to jump into the menu line This function is not available in all menus Calling the SAS IME configuration program gt Start the PC if the following message appears press the key combination CTRL and C Press Ctrl C to start LSI Logic Configuration Utility D2119 RX300 S3 Technical Manual 31 SAS IME configuration program SAS and RAID Following hint appears next Please wait invoking LSI Logic Configuration Utility In the first menu all available SAS controllers are displayed fist Logic MPT Setup Utility Adapter List Global Properties Adapter PCI PCI PCI PCI FW Revision Status Boot Bus Dev FNC Slot Order SAS1068 02 08 00 00 1 10 01 00 IR Enabled 0 Esc Exit Menu F1
32. x Target devices to Spinup C 01 Esc Exit Menu F1 Shift l Help Spinup Delay Defines the intervals for the spinup of the hard disks The default setting is 2 When this feature is enabled the SAS devices which support this function are not started by switching on the server until they receive a Start Unit command from BIOS of the SAS controller This function is used to distribute the high starting currents of the SAS devices over a specific period and to release the power supply of your server D2119 RX300 S3 Technical Manual 39 SAS IME configuration program SAS and RAID Menu P HY Properties It is recommended don t change this setting Discovery Status Device Identifier Scan Order Device Information SAS Address isi Logic MPT Setup Utility PHY Properties SAS1068 PHY 0 1st of 8 PHYs SAS Port 0 Link Status Enabled 3 0 Gbps 000000 SEAGATE ST3146854SS 0 SAS 5000C500 0000EB39 1501 Esc E Enter k xit Menu F1 Shift 1 Reset Phy error logs Help Alt N Next Phy Alt P Previous Phy 40 Technical Manual D2119 RX300 S3 SAS and RAID RAID on Motherboard ROMB 4 2 RAID on Motherboard ROMB Components On the system board a high performance SAS RAID Controller MegaRAID SAS PCI Express ROMB is implemented The RAID solution consists of the Intel IOP332 I O processor with integrated PCI E to PCI X b
Download Pdf Manuals
Related Search
Related Contents
Palm OTDR DocuStation C3375 CS [PDF:1811KB] SDT_ Manual - JLC International Bedienungsanleitung lavadora semiautomática estimado cliente índice MATERIAL DIDÁTICO 128 Escola Técnica Electra – NR Massive Suspension light 40538/31/10 Targus Made By Me KCA-iP500 Lunos e2 user manual - 475 - 475 High Performance Building Supply Copyright © All rights reserved.